Вы находитесь на странице: 1из 22

BASIC Fieldmate

R1.02
for the Salesperson
Yokogawa Electric Corporation

FOR INTERNAL USE ONLY

<Document Number>
Copyright Yokogawa Electric Corporation
<date/time>

What is Fieldmate ?

FOR
A single tool for the management of field devicesINTERNAL
It supports both the FDT and DD technology
USE
It helps in
- initial setup
- configuration
- daily maintenance and
- troubleshooting of field devices.

Using NI-FBUS card

<Document Number>
Copyright Yokogawa Electric Corporation
<date/time>

Using HART modem

FDT Technology
FDT = Field Device Tool, but it is not a tool
FDT is an open INTERFACE SPECIFICATIONS.

FOR
INTERNAL
USE

It defines the system environment in which the DTM runs.


DTM (Device Type Manager) is a device driver encapsulating all
the device functions.
It is similar to printer driver.

More details at
www.fdtgroup.org

<Document Number>
Copyright Yokogawa Electric Corporation
<date/time>

What is included in Fieldmate CD ?

FOR
INTERNAL
USE

Please note that it contains ALL DD that is registered with the


HART COMMUNICATION FOUNDATION and the Fieldbus FOUNDATION
<Document Number>
Copyright Yokogawa Electric Corporation
<date/time>

Example of HART Device Setup

FOR
INTERNAL
USE

<Document Number>
Copyright Yokogawa Electric Corporation
<date/time>

Example of FF-H1 Device Setup

FOR
INTERNAL
USE

<Document Number>
Copyright Yokogawa Electric Corporation
<date/time>

Why Buy Fieldmate ?

Easy to use (Plug and Play)

FOR
INTERNAL
USE

Easy to access field device parameter


Trending helps to troubleshoot
intermittent device fault
Keeps history of what has been done
Supports multiple protocols
<Document Number>
Copyright Yokogawa Electric Corporation
<date/time>

Intuitive Operation from Segment Viewer

FOR
INTERNAL
USE

Easy to Use Fieldmate


Easy to Access field devices

<Document Number>
Copyright Yokogawa Electric Corporation
<date/time>

HART Device using DTM for Initial Setup

FOR
INTERNAL
USE

Easy Setup
Menu
tree

<Document Number>
Copyright Yokogawa Electric Corporation
<date/time>

FF Device using DD (Device Description)


for setting parameter

FOR
INTERNAL
USE

Parameter Manager
Screen

- Magenta is writable
- Yellow is read-only

<Document Number>
Copyright Yokogawa Electric Corporation
<date/time>

Device Viewer for troubleshooting

FOR
INTERNAL
USE

<Document Number>
Copyright Yokogawa Electric Corporation
<date/time>

Trending to help in troubleshooting

FOR
INTERNAL
USE

Exporting trends to Excel Spreadshe

<Document Number>
Copyright Yokogawa Electric Corporation
<date/time>

DD Menu for FF Device Calibration

FOR
INTERNAL
Zeroing of transmitter
USE

<Document Number>
Copyright Yokogawa Electric Corporation
<date/time>

Loop Test to verify Device Operational


Health

<Document Number>
Copyright Yokogawa Electric Corporation
<date/time>

FOR
INTERNAL
USE

History will display all operation logs

FOR
INTERNAL
USE

<Document Number>
Copyright Yokogawa Electric Corporation
<date/time>

Tag/Address Assignment for FF Devices

FOR
INTERNAL
USE

For HART : 0 to 15
For FF-H1 : 16 to 247
<Document Number>
Copyright Yokogawa Electric Corporation
<date/time>

Printing from Device DTM

FOR
INTERNAL
USE

Simple Powerful
Feature
which HHT cannot do

<Document Number>
Copyright Yokogawa Electric Corporation
<date/time>

Differentiating FUNCTION use for HART &


FF

Segment Viewer
Which
Device Viewer
is BEST
DTM
Parameter Manager for use ?
DD Menu

<Document Number>
Copyright Yokogawa Electric Corporation
<date/time>

FOR
INTERNAL
USE

Contributing to Project Commissioning


Phase
Verify Tag

FOR
INTERNAL
USE

Checking configuration against Documentat

Confirm Configuration
- Upper Range Values
- Lower Range Values
- Engineering Units
- Damping
Confirm Device Materials
- Diaphragm
- Flanges
- O rings
- Fill Fluids
Check zero
Checking secondary value
Loop Test
<Document Number>
Copyright Yokogawa Electric Corporation
<date/time>

FASTER CHECKOUT OF DEVICE

Contributing to Lower Life Cycle Costs


Manage maintenance remotely
Reduce unnecessary maintenance
activities
Maintenance
Change configuration
Perform calibration
Checks Device Status and Alerts
Reduce troubleshooting time
Opening multiple device viewer
to help reduce troubleshooting
time

<Document Number>
Copyright Yokogawa Electric Corporation
<date/time>

FOR
INTERNAL
USE

Summary

All HART device DD and Generic DTM

FOR
INTERNAL
USE

All FF-H1 device DD


Yokogawa device Custom DTM (5 devices)
No Apple to Apple comparision against
other FDT application & HHT.
Use as Trojon Horse for competitive
site, more careful about ABB
<Document Number>
Copyright Yokogawa Electric Corporation
<date/time>

Action Plan
Mailing of Fieldmate flyer
- mass distribution
- include in proposal ( project, MRO )

FOR
INTERNAL
USE

Fieldmate site demo for 1 to 1 promotion to customer


Convert all HHT enquiry into Fieldmate
Sell to EPC ( maybe bundle )

<Document Number>
Copyright Yokogawa Electric Corporation
<date/time>

Вам также может понравиться