SIZING PIPE of N2 GASES STREAM from CP-53 and MPN
as OIL LUBRICATING SYSTEM SEALING at ST-18

On 2014, ASU steam turbine (ST-18) has


experienced oil leaking many times and one of
fire incident caused by ST-18 oil leak ever
happened also on 2014.

INTRODUCTION

An investigation has been conducted


and it was found that during this steam
turbine 18 has been in operation without
any seal gas introduced to its oil system.

INTRODUCTION

To prevent oil leak and fires incident happening


again, a modifications will be made at CP-53
discharge vent line and nitrogen medium pressure
(MPN) system to provide seal gas to steam turbine
18 oil system.
Whereas the purpose of this study are
DETERMINE THE SIZE OF PIPE that will be used
for N2 gases stream from CP-53 and MPN as ST-18
Oil Lubricating System Sealing and its installation.

OBJECTIVE

Compressor
CP-53
Pressure
bar

:5

MPN
Pressure :
4,6 bar

Initial Condition

ST-18 Sealing
Pressure :
3,005 bar

Calculating diameter size of pipe that will be


used is also using calculation of pressure drop
from source into a goal. On calculating, this
study use CHEMCAD software. Using Chemcad
is intended to allow more efficient computation,
because the process is using TRIAL and
ERROR method from the smallest pipe size.

Calculating Method

Before use Chemcad software, it is


needed the flowrate value of N2 stream.
This calculation use Coefficient Flow
formula.

Pre-Calculating

Determine Coeficient Flow from Technical


Specification of Regulator
Velocity Gas
: 10 m/s
Max Flow in 0.5 inch pipe
: 720 ft3/h (12 scfm)
: 159,54 Psia (10 barg)
Inlet Pressure (Pi)
Outlet Pressure (Po)

: 114,57 Psia (6,9 barg)

: 44,97 Psia (dp = Pi-Po)


Pressure Drop (dp)
Temperature (T)
: 32 F (0o C)
Coeficient Flowrate (Cv) ?

Determine Flowrate (Q) from Coefficient Flow


(Cv)
Velocity Gas
: 10 m/s
Coefficient Flowrate
: 0.163
Inlet Pressure (Pi)
: 87,02 Psia (5 barg)
Outlet Pressure (Po)
: 65,26 Psia (3,5 barg)
Pressure Drop (dp)
: 21,76 Psia (dp = Pi-Po)
Temperature (T)
: 32 F (0o C)
Flowrate (Q) ?

Temperature : 40C
Pressure : 6 bara
Total Flow : 10,17 stdV m3/h
Mole Fraction Nitrogen: 1
Pipe Diameter : 0,5 in
Pipe Schedule : 40
Pipe Length: 51,42 m

Elevation : 6,96 m
Pipe Material : Commercial Steel
Ball Valve : 3
Swing Check : 1
Elbow 90 deg : 15
Tee : 1

Input Chemcad from CP-53

Simulating N2 stream from CP-53 by


ChemCad

Temperature : 40C
Pressure : 5,6 bara
Total Flow : 10,17 stdV m3/h
Mole Fraction Nitrogen: 1
Pipe Diameter : 0,5 in
Pipe Schedule : 40
Pipe Length: 39,52 m

Elevation : 6,96 m
Pipe Material : Commercial Steel
Ball Valve : 3
Swing Check : 1
Elbow 90 deg : 15
Tee : 1

Input Chemcad from MPN

Simulating N2 stream from MPN by


ChemCad

The ChemCad simulation for N2


gases stream from CP-53 shows the
final pressure bigger than 3,5 bar,
which one is 4,9647 bar of
pressure. This shows that the
simulated trial suit the demand
of process needed.

Result

THANK YOU

Вам также может понравиться