Вы находитесь на странице: 1из 31

PCS 7/90 OS V7.

0
Overview of
Benefits
SIMATIC PCS 7
Takes you beyond the limits!

Bailey OS V7.0 Featured Benefits Include:


Improved System Robustness
Overview of
Benefits

New Choices for Engineering Packages

Order Numbers

License Management Unified within PCS 7

Supported
Architectures

Improved Engineering Efficiency (More Automation in DBA)

Upgrading From
V6.x to V7.0

Redundant PCS 7 Historian

Add PCS 7
Controllers

Broader PCS 7 Connectivity Options (OpenPCS 7)


Expand Operations Via the Web
Improve Operator Response to Emergency Alarms
Faceplate and Symbols added for FC194
Advanced Tuning View

Copyright Siemens AG 2005


All Rights Reserved

04/2008

Bailey OS

Improved System Robustness

PCS 7, Operating System, and PC Support


Bailey OS V7.0 will be bundled with PCS 7 V7.0 SP2.
Operating Systems supported will be the same as PCS 7 V7.0 SP1:
Overview of
Benefits
Order Numbers

XP SP2 and Server 2003 SP2

Improved SIMATIC PCs for Engineering/Operator Station


SIMATIC Rack PC 547B

Intel 945G Express chipset with Intel Pentium CORE 2 Duo processor E6600

Supported
Architectures

Intel processor technology with 64-bit expansion


Intel Extended- Memory-64 Technology for future 64-bit applications

Upgrading From
V6.x to V7.0

DDR2 677 SDRAM memory technology with dual channel support


Memory expandable up to 4 GByte

Intel GMA950 graphics controller


with dynamic Video Memory Technology integrated in chipset

Intel Matrix Storage Technology RAID controller integrated in ICH7R chipset

Powerful 250 GByte Serial ATA hard disks (SATA) with NCQ technology

PCI-Express slots for expansions

Gigabit Ethernet integrated

Add PCS 7
Controllers

Manufactured by Siemens
Long Term Support from Siemens
Industrial Rugged Construction

Copyright Siemens AG 2005


All Rights Reserved

Faster PCs using the latest versions of PCS 7 and Microsoft operating systems
reduces susceptibility to unexpected failures.

04/2008

Bailey OS

New Choices for Engineering Packages


System Architecture Applications
OS Clients/pieces of
glass (32 total per
Server)

Overview of
Benefits
Order Numbers

OS
Engineering

Ethernet

1a

Supported
Architectures

New

OS Clients/pieces of
glass (32 total per
Server)
Ethernet

OS Servers
(up to 16 OS
Server
Pairs)

Upgrading From
V6.x to V7.0

Standalone Engineering Station with Unlimited


POs

Add PCS 7
Controllers

1a

OS Engineering with
Unlimited POs with a 2-hour
limit for Runtime Operation

1b

OS Engineering with 250


POs with Runtime Operation

OS
Engineering
And Client

OS Servers
(up to 16 OS
Server
Pairs)

1b

Engineering Station used as a Client PCS 7


Power Packs available to support more than
250 OS POs

1b

OS
Engineering
and Single
Station or
Server

Ethernet

Engineering Station used as Single Station or Server

PO = Process Object
Copyright Siemens AG 2005
All Rights Reserved

PCS 7 Power Packs available to support more than


250 OS POs

Purchase what you need by choosing the Engineering package that meets your
system architecture needs.

04/2008

Bailey OS

*new starting in PCS 7 V7.0 SP1

PCS 7 Process Object (PO)

A Process Object is a control function which includes


alarming* and has HMI content (a Faceplate)
Overview of
Benefits

1 PO

Order Numbers

Function Block
(e.g. Motor)

HMI Faceplate

Supported
Architectures
Upgrading From
V6.x to V7.0
Add PCS 7
Controllers

Includes Alarming
(e.g. Monitoring
Time exceeded)

+
Runs in the controller

Runs on the Operator Station

Counting Process Objects simplifies Server Licensing by counting objects


instead of counting individual object attributes.
Copyright Siemens AG 2005
All Rights Reserved

90 OS Process Object (PO)

Overview of
Benefits
Order Numbers
Supported
Architectures
Upgrading From
V6.x to V7.0
Add PCS 7
Controllers

*new in 90 OS V7.0

DBA will not mark structures created in PCS 7 that


represent Bailey Function Codes as Process Objects
(PO).
The number of Process Objects is calculated by
dividing all external tags by 25.
This was done to streamline licensing since on
average, Bailey Function Codes result in less than 15
external tags.
This was also done to ensure the upgradeability of V6.1
projects without the need to add power packs.

Counting Process Objects simplifies Server Licensing and uses the same
definitions used by PCS 7.
Copyright Siemens AG 2005
All Rights Reserved

License Management Unified within PCS 7

Details

90 OS now counts Process Objects

Starting in PCS 7 V7.0 SP1 WinCC will begin to count


Process Objects rather than WinCC tags.
Overview of
Benefits

DBA will not mark 90 OS created structures as Process


Objects even though they include Messages/Alarming.

Order Numbers

The new license schema does two calculations:

Supported
Architectures

Upgrading From
V6.x to V7.0

Add PCS 7
Controllers

POs = POs counted + (Non PO external tags/25)


-

WinCC Structures without Alarming


POs = All External Tags/50

As an Example:

In V6.1 64,000 WinCC Tags = 2000 POs

In V7.0 64,000 WinCC Tags = 1280 POs

The calculated PO number in the above two calculations must


not exceed the # of licensed POs.
90 OS projects average less than 15 tags per Process Object,
therefore this should not be an issue when upgrading to V7.0.

Copyright Siemens AG 2005


All Rights Reserved

Using the same License Management concept as PCS 7 simplifies system


specification with expansions using PCS 7.

04/2008

Bailey OS

Improved Engineering Efficiency


(More Automation in DBA)

Overvie
w

A Technological Win-Win
Lock-down updates to a Picture
Overview of
Benefits

Prevents unwanted changes to symbols/block icons.

Direct Import of SCADA PLC Tags

Order Numbers

Supported
Architectures

Utilizes the existing Engineering effort that has already been done to define 3 rd
Party devices integrated into InTouch via OPC Servers, typically PLCs.

This import includes the definition of scale, engineering units, description, and
alarm/message definitions.

Upgrading From
V6.x to V7.0
Add PCS 7
Controllers

DBA import of the TTG file has been extended to read the
number of decimal places to display and automatically
applies these definitions to PCS 7.
Auto-Generate Tag Logging

Eliminates separate engineering steps currently required to define tags to be


logged.

Reduce the time and costs required to engineer projects that include customized
controller objects, by reducing errors through automation.
Copyright Siemens AG 2005
All Rights Reserved

04/2008

Bailey OS

DBA V7.0

Simplified Tag Import of Tags from Third Party Devices


One target system
PCS 7

DBA User Interface

Overview of
Benefits
Order Numbers
Supported
Architectures

Bailey Plug-in
OPC
ES
Data

Upgrading From
V6.x to V7.0
Add PCS 7
Controllers

1-Line csv file Direct


Database Import

Provides Support for Integrating any PLC, such as Allen


Bradley or Modicon for which an OPC Server exists.
This import includes the definition of scale, engineering units,
description, and alarm/message definitions.
Bailey
Engineering costs are reduced by eliminating the need to manipulate csv files,
thereby saving time and effort.
Copyright Siemens AG 2005
All Rights Reserved

04/2008

Bailey OS

Auto-Generate Tag Logging

Add Tags to History based on Type Definition


In DBA the user selects tags for historization by the OS Server
Overview of
Benefits

Define storage frequency and define


as ShortTerm or LongTerm storage.

Order Numbers
Supported
Architectures
Upgrading From
V6.x to V7.0
Add PCS 7
Controllers

Copyright Siemens AG 2005


All Rights Reserved

Standard Trending available in PCS 7 has been improved in V7.0.

Bailey OS V6.1 Enhanced Trend now included since PCS 7 V7.0.


The trend control now allows the user to export the trend trace data displayed on a
trend.

Engineering costs are reduced by being able to define historization


requirements on a type basis.

04/2008

Bailey OS

10

New

SIMATIC PCS 7 Operator System


Historian
OS Client

Overview of
Benefits
Order Numbers
Supported
Architectures
Upgrading From
V6.x to V7.0
Add PCS 7
Controllers

Redundant
OS Server

Standard PCS 7
Short-term
archive

Redundant Central
Archive Server

Long-term
archive
Back up and
Export

Archive on PCS 7 OS Server:


Tags (e.g. PID001.SP)
Alarms and Events

High Performance Microsoft SQL Server 2005 max. 1000 process values /sec.
Archive Synchronization between redundant Servers
Store up to 10,000 Tags on the OS Server

Central Archive Server:


Archiving of several OS Servers (Tags, Alarms & Events)
Long Term Storage and Data Export (DVD, EXCEL)
Store up to 120,000 Tags on the Central Archive Server
Redundant Central Archive Server Supported

Copyright Siemens AG 2005


All Rights Reserved

Operations can seamlessly view data improving their ability to manage the
process.

04/2008

Bailey OS

11

Broader PCS 7 Connectivity Options


Data Access via OPC using OpenPCS 7

Type of Data supported via OpenPCS 7


Overview of
Benefits
Order Numbers
Supported
Architectures
Upgrading From
V6.x to V7.0
Add PCS 7
Controllers

OPC

Data Type

Type of Access

OS Server

DA

Variables of process operation

Read/Write

OS Server

A&E

Alarms & Events

Read/Ackn.

A&E

Historical Alarms & Events

Read

OS Server

HDA

Historical measuring values

Read

CAS

A&E

Historical Alarms & Events

Read

HDA

Historical measuring values

Read

OS Server

New

New

CAS

OS Client Station
with OPEN PCS 7

OS Single Station
with built in OPC Server

OS

Office
Network

OPC Client

OS
Client

OPC Client

OS
Client

Bailey
CIUs

Copyright Siemens AG 2005


All Rights Reserved

04/2008

OPC DA

Bailey OS

OPC DA, HDA and AE

12

Expand Operations Via the Web

Bailey OS Faceplates support Read/Write Functionality


Standard Office PC
Overview of
Benefits
Order Numbers

PCS 7 Web Server


on an OS Client

Supported
Architectures
Upgrading From
V6.x to V7.0
Add PCS 7
Controllers

OS Server

Bailey

PCS 7
Reduce operating costs by consolidating multiple control rooms during all
phases of plant operation or to better manage the operational needs during offpeak production times.
Copyright Siemens AG 2005
All Rights Reserved

04/2008

Bailey OS

13

Identification of Emergency Response Required Alarms

Overview of
Benefits

New

Icon on Alarm one line is visible when at least one alarm with
Priority Class 16 is active.
Alarm list shows Highest Priority Alarms

Order Numbers
Supported
Architectures
Upgrading From
V6.x to V7.0
Add PCS 7
Controllers

Copyright Siemens AG 2005


All Rights Reserved

Improving operator response to alarms ensures that alarms that require an


Emergency Response are not lost in the alarm flood that can occur during a
plant upset.

04/2008

Bailey OS

14

The Operator can choose Alarms to Hide

New

Hide/Unhide Messages
Overview of
Benefits
Order Numbers
Supported
Architectures
Upgrading From
V6.x to V7.0

Alarms remain hidden for a pre-determined period of time; minutes, hours, or days

The alarms will continue to be generated and logged, however the system will
auto-acknowledge them.

List of Hidden Alarms currently in Alarm

Add PCS 7
Controllers

List of Hidden Alarms

Copyright Siemens AG 2005


All Rights Reserved

Improving operator response to alarms ensures that alarms that require an


Emergency Response are not lost in the alarm flood that can occur during a
plant upset.

04/2008

Bailey OS

15

Symbol and Faceplate for FC194

Overview of
Benefits
Order Numbers
Supported
Architectures
Upgrading From
V6.x to V7.0
Add PCS 7
Controllers

The standard view is the default view when the faceplate is first displayed
from the symbol or opened directly in the Group Display mode.
The faceplate displays the block descriptions, the current mode, and the
current TEXTSTR.
It also allows the operator to enter a response.

Copyright Siemens AG 2005


All Rights Reserved

04/2008

Bailey OS

16

Advance Tuning View

Fully Supported via a Web Client


The Advanced Tuning View allows the user to modify runtime configurable spec
parameters in runtime.
Overview of
Benefits
Order Numbers
Supported
Architectures

In addition all other spec parameters can be configured by putting the controller in
Configure Mode from the Tuning View.
This functionality requires the user to create a new security level to limit access to
this feature. Also the user can view data as polled rather than report by exception
for any block in the controller.

Upgrading From
V6.x to V7.0
Add PCS 7
Controllers

Displays live values via Polling.


Copyright Siemens AG 2005
All Rights Reserved

04/2008

Bailey OS

17

Additional Topics

Overview of
Benefits

In V6.1 the Station Block output in manual used the same limits as
imposed during Auto. This has been changed to allow users to
separately define the limits to be imposed during manual operation.
The defaults will be 0-100.

Order Numbers
Supported
Architectures
Upgrading From
V6.x to V7.0
Add PCS 7
Controllers

Copyright Siemens AG 2005


All Rights Reserved

Symbols and Faceplates have been updated to include the attributes for
defining an Archive Trend. The default definition is to display a Live
Trend.
Symbols and Faceplates were updated so that the symbol is highlighted
when the faceplate is opened from the symbol. In V6.1 the symbol was
highlighted only when opening the graphic using Loop-in-Alarm.

04/2008

Bailey OS

18

Product Part Numbers

Overview of
Benefits
Order Numbers
Supported
Architectures
Upgrading From
V6.x to V7.0
Add PCS 7
Controllers

Copyright Siemens AG 2005


All Rights Reserved

Product

Order No.

1a

OS Engineering Package
Unlimited POs
Runtime Not Included

PCS 7/90 OS Engineering Pack,


V7.0 (PO Unlimited)

6EQ2003-1BD07-3BA5

1b

OS Engineering Package
Runtime Included
(PO 250)

PCS 7/90 OS Engineering Pack,


V7.0 (PO 250)

6EQ2003-1BA07-3BA5

OS Redundant Server
Package (PO 250)

PCS 7/90 OS Redundant Server


Pack, V7.0 (PO 250)

6EQ2003-2GA07-3BA0

OS Server Package
(PO 250)

PCS 7/90 OS Server Pack, V7.0 (PO


250)

6EQ2003-2HA07-3BA0

OS Single Station Package


(PO 250)

PCS 7/90 OS Single Station Pack,


V7.0 (PO 250)

6EQ2003-2AA07-3BA0

OS Client V7.0

PCS 7 OS Client V7.0 (This is the

6ES7658-2CX07-0YA5

04/2008

standard PCS 7 OS Client Package.)

Bailey OS

19

Small Systems using a Single Workstation


Combination Console - Engineering and Operation

250 1,000 PO

Multi-VGA Graphics Cards Available


2 Monitors 6ES7 652-0XX03-1XE0
4 Monitors 6ES7 652-0XX03-1XE1

Overview of
Benefits

PCS 7
Engineering

Order Numbers
Supported
Architectures

Use Case
Small Plants with combined
Engineering and OS Runtime
Features
Multi VGA card can be used to
operate with up to 4 Monitors
one Mouse, one Keyboard
Online OS Engineering

Upgrading From
V6.x to V7.0
OS Runtime

Add PCS 7
Controllers

RS232 or SCSI

1b

Could also be PCS 7 Box

CIU

Copyright Siemens AG 2005


All Rights Reserved

PCS 7 offers cost effective alternatives to meet your control room operational
requirements.

04/2008

Bailey OS

20

Multiple OS Single Stations with a Low Cost Web Solution


500 2,000 PO

ES without
OS Runtime
Overview of
Benefits

1a ES

OS Single
Station

4 OS

4 OS
Office Bus (could be wireless)

Order Numbers
Supported
Architectures
Upgrading From
V6.x to V7.0
Add PCS 7
Controllers

Terminal
Bus
CIU

RS232 or SCSI

Max. 3 Web Client


With Web Client Software
CIU

OS Single Station with Web Server


3 Clients 6ES7 658-2GA07-2YB0

Single Station Redundancy 6AV6371-CF06-2AX0


RS 232 Cable 10M 6ES7902-1AC00-0AA0

Use Case
Redundant Operator Stations
OS Archive (Tags and Events) run requires Single Station Redundancy to
synchronize the two OS Single Stations
Use WIN2003 Server Operating System on both Single Stations
Low Cost Web Solution for up to 3 Web Clients
More than 2 Single Operator Stations is not recommended (use client Server)
Copyright Siemens AG 2005
All Rights Reserved

PCS 7 offers cost effective alternatives to meet your control room operational
requirements.

04/2008

Bailey OS

21

Small System Client Server Architecture


Servers used for Operations
1b

Overview of
Benefits

1,000 5,000 PO

Order Numbers
Supported
Architectures
Upgrading From
V6.x to V7.0
Add PCS 7
Controllers

Terminal Bus
RS232 or SCSI

ES /
OS Client

CIU

CIU

OS Redundant
Servers

OS Client with dual


monitor card

Use case
Low Cost Client Server architecture
Synchronized Historian Archive on the OS Servers
Features
Server used for operations max. 4 Monitors can be connected
Servers can connect directly to the CIU via RS232 or a SCSI.

Copyright Siemens AG 2005


All Rights Reserved

PCS 7 offers cost effective alternatives to meet your control room operational
requirements.

04/2008

Bailey OS

22

Medium to Large System Architecture


Fully Redundant OS System

Overview of
Benefits

1a OS
ES

2,000 60,000 PO

Up to 12 OS Server Pairs
OS Redundant Server Package

Order Numbers
Supported
Architectures
Upgrading From
V6.x to V7.0
Add PCS 7
Controllers

Copyright Siemens AG 2005


All Rights Reserved

OS

Up to 32

5
OS

Terminal Bus
RS232 or SCSI

CIU

CIU

Usecase
Fully Redundant Operator Stations
Features
Archive Synchronization (Messages and Tags) between 2 OS Server Stations,
no gaps in Trends and logs after a PC failure
Online Configuration possible while both OS Servers Stations run
Higher Availability than one Server and one Client

PCS 7 offers cost effective alternatives to meet your control room operational
requirements.

04/2008

Bailey OS

23

Order Information

Update an existing PCS 7/90 OS V6.x Installation to V7.0


Product
Overview of
Benefits
Order Numbers
Supported
Architectures
Upgrading From
V6.x to V7.0
Add PCS 7
Controllers

* 90 OS
Engineering
Upgrade
Package

** 90 OS
Runtime Upgrade
Package

*** Client

Order No. V7.0

PCS 7/90 OS Upgrade Package


Engineering OS V6.x-> V7.0

6EQ2003-1XX07-3BE5

PCS 7/90 OS Upgrade Package Runtime


OS V6.x -> V7.0

6EQ2003-2XX07-3BE0

Upgrade Package OS Client V6.x -> V7.0

6ES7 652-5CX07-0YE5

Upgrade
Package

* Order one package for each 90 OS Engineering Station.

The
engineering station upgrade package provides two license disks. One
will upgrade to Runtime with the number of POs currently licensed for.
Or the other upgrade disk can be used to upgrade the engineering
station to Unlimited POs without unlimited runtime.

** Order one package for each 90 OS Server or Single Station


Copyright Siemens AG 2005
All Rights Reserved

*** Order one package for each Client Station

04/2008

Bailey OS

24

Add PCS 7 Controllers to a 90 OS System

Software to be added to 90 OS packages using Siemens PCs w/BCE


Ethernet

Overview of
Benefits

PCS7/90 OS Servers

PCS 7/90 OS
Engineering

Industrial Ethernet

Order Numbers
CIU

Supported
Architectures
Upgrading From
V6.x to V7.0
Add PCS 7
Controllers

Product

Order No. V7.0

AS Engineering
Add to Engineering Station

PCS 7 AS Engineering Software

6ES7 658-1AF07-0YA5

POs for AS
Add to Engineering Station

PCS 7 AS Runtime License 1000

6ES7 653-2BB00-0XB5

POs

* Other AS Runtime License sizes are available.

Copyright Siemens AG 2005


All Rights Reserved

04/2008

Bailey OS

25

Add PCS 7 Controllers to an 90 OS System

Software to be added to 90 OS packages using Siemens PCs w/BCE


Ethernet

Overview of
Benefits

Add
1613 Card

PCS 7/90 OS
Engineering

PCS7/90 OS Servers
Industrial Ethernet

Order Numbers
CIU

Supported
Architectures
Upgrading From
V6.x to V7.0
Add PCS 7
Controllers

Product

Order No. V7.0

AS Engineering
Add to Engineering Station

PCS 7 AS Engineering Software

6ES7 658-1AF07-0YA5

POs for AS
Add to Engineering Station

PCS 7 AS Runtime License 1000


POs

6ES7 653-2BB00-0XB5

Siemens PCs W/BCE (IL547B) With Redundant Controllers

Add to Engineering and each OS Server

Copyright Siemens AG 2005


All Rights Reserved

CP 1613 A2 PCI Card

SIMATIC NET, IE, CP1613 A2 PCI


Card

6GK1 161-3AA01

SIMATIC NET S7REDCONNECT/2006

S7-REDCONNECT/2006

6GK1 716-0HB64-3AA0

* For non-redundant controllers no additional components needed

04/2008

Bailey OS

26

Add PCS 7 Controllers to an 90 OS System

Software to be added to 90 OS packages using Siemens PCs w/IE


Ethernet

Overview of
Benefits

Includes
1613 Card

PCS 7/90 OS
Engineering

PCS7/90 OS Servers
Industrial Ethernet

Order Numbers
CIU

Supported
Architectures
Upgrading From
V6.x to V7.0
Add PCS 7
Controllers

Product

Order No. V7.0

AS Engineering
Add to Engineering Station

PCS 7 AS Engineering Software

6ES7 658-1AF07-0YA5

POs for AS
Add to Engineering Station

PCS 7 AS Runtime License 1000


POs

6ES7 653-2BB00-0XB5

Siemens PCs w/IE (IL547B) With Redundant Controllers

Add to Engineering and each OS Server


REDCONNECT Upgrade

S7-REDCONNECT Upgrade

6GK1 716-0HB64-3AC0

* For non-redundant controllers no additional components required.


Copyright Siemens AG 2005
All Rights Reserved

04/2008

Bailey OS

27

Software to be added to 90 OS packages

For Non Siemens PCs w/ Non Redundant Controllers


Ethernet

Overview of
Benefits

Add
BCE

PCS 7/90 OS
Engineering

PCS7/90 OS Servers
Industrial Ethernet

Order Numbers
CIU

Supported
Architectures
Upgrading From
V6.x to V7.0
Add PCS 7
Controllers

Product

Order No. V7.0

AS Engineering
Add to Engineering Station

PCS 7 AS Engineering Software

6ES7 658-1AF07-0YA5

POs for AS
Add to Engineering Station

PCS 7 AS Runtime License 1000 POs

6ES7 653-2BB00-0XB5

Non Siemens PCs With Non Redundant Controllers


Add to Engineering and each OS Server
Server to Controller
Communications

Copyright Siemens AG 2005


All Rights Reserved

04/2008

PCS 7 BCE V7.0

Bailey OS

6ES7 650-1CD07-2YB5

28

Software to be added to 90 OS packages


For Non Siemens PCs w/Redundant Controllers
Ethernet

Overview of
Benefits

PCS 7/90 OS
Engineering

Add
1613 Card

PCS7/90 OS Servers
Industrial Ethernet

Order Numbers
CIU

Supported
Architectures
Upgrading From
V6.x to V7.0
Add PCS 7
Controllers

Product

Order No. V7.0

AS Engineering
Add to Engineering Station

PCS 7 AS Engineering Software

6ES7 658-1AF07-0YA5

POs for AS
Add to Engineering Station

PCS 7 AS Runtime License 1000 POs

6ES7 653-2BB00-0XB5

Non Siemens PCs With Redundant Controllers


Add to Engineering and each OS Server

Copyright Siemens AG 2005


All Rights Reserved

CP 1613 A2 PCI Card

SIMATIC NET, IE, CP1613 A2 PCI Card

6GK1 161-3AA01

SIMATIC NET S7REDCONNECT/2006

S7-REDCONNECT/2006

6GK1 716-0HB64-3AA0

04/2008

Bailey OS

29

New

Advanced Process Control for Bailey Systems


Solution:
Overview of
Benefits

Use the OS Server to pass Process Data and Setpoints between the Advanced
Control Algorithm running in the Microbox and the Bailey controller.
Engineering Station

Order Numbers

PCS 7 Bailey OS Engineering


PCS 7 AS Engineering Software
PCS 7 AS Runtime License 100 POs

Supported
Architectures
Upgrading From
V6.x to V7.0
Add PCS 7
Controllers

Ethernet

Bailey OS
Server

PCS 7 AS RTX
Controller:
WinAC RTX (Soft-CPU)
PC: Microbox PC 427B

Add Advanced Process Control to Bailey Systems using Standard PCS 7


Products.
Copyright Siemens AG 2005
All Rights Reserved

04/2008

Bailey OS

30

Thank you
very much
SIMATIC PCS 7
Takes You Beyond the Limits
of MIGRATION!