POWER PLANT

IDENTIFICATION SYSTEM
KRAFTWERKS-KENNZEICHNUNGS-SYSTEM (KKS)

Export Classifications
AL:N
ECCN:EAR99

POWER PLANT IDENTIFICATION SYSTEM

KKS Basics

Identification of:
Plants
Systems
Equipments
Signals
Protection notice / Copyright notice

Page 2

2011-03

E S SF REU 444

Export Classifications
AL:N
ECCN:EAR99

KKS - CATEGORIES OF KKS CODE


Process-related identification
Identification of systems and items of equipment according to their
functions in mechanical, civil, electrical and I&C (Instrumentation
and Control) engineering.
Mounting location identification
Identification of mounting locations of electrical and I&C equipment
in mounting units such as cabinets, panels and consoles.
Topographic location identification
Identification of topographic allocations in structures, floors, rooms
and enclosures

Protection notice / Copyright notice

Page 3

2011-03

E S SF REU 444

Export Classifications
AL:N
ECCN:EAR99

KKS - PROCESS RELATED IDENTIFICATION

FID

SID

11MBY10CS901.XQ01
Function Identification Code (FID)

Signal Identification Code (SKZ/SID)

the unique identification of a component


or function plan (logic).

the unique identification of a signal defined


on a function plan.

Protection notice / Copyright notice

Page 4

2011-03

E S SF REU 444

Export Classifications
AL:N
ECCN:EAR99

KKS - PROCESS RELATED IDENTIFICATION

A/N N

MBP 13 AA 001
AAA NN AA NNN

_ XB 01 -> practical example


A AA NN

-> systematics: N = number


A = character
Signal Serial Number
Signal Identification Code

Equipment Redundancy (Optio


Equipment Serial No.

Equipment Identification Code


System Area Serial No.
System Identification Code
Unit Code
Plant Code
Protection notice / Copyright notice

Page 5

2011-03

E S SF REU 444

Export Classifications
AL:N
ECCN:EAR99

KKS FID
Plant Identification: code with two numbers

MBP 13 AA 001

Plant Code (here plant 1)


identifies largest grouping of
plant equipment.
The plant can include multiple
generating sets and common
systems
Unit Code (here: Block 2)
identifies the specific
generating unit within the
plant.

XB 01

Example: Plant with 4 gas turbine units:

PLANT /
UNIT
CODE
00

UNIT
STATION

11

GENERATING UNIT #1, COMMON


SYSTEMS
GENERATING UNIT #1, GAS TURBINE #1

12

GENERATING UNIT #1, GAS TURBINE #2

20
21

GENERATING UNIT #2, COMMON


SYSTEMS
GENERATING UNIT #2, GAS TURBINE #1

22

GENERATING UNIT #2, GAS TURBINE #2

10

Protection notice / Copyright notice

Page 6

2011-03

E S SF REU 444

Export Classifications
AL:N
ECCN:EAR99

KKS FID
System Identification: Code with 3 characters and 2 numbers.

MBP 13 AA 001

o M Main Machine Set

Sub group of major


system:

o H Steam Generation
o E Fuel Delivery
o L Steam-Water-Cycle

XB 01

Individual System of major


system:

o MA Steam Turbine

o MAA HP Steam Turbine

o MB Gas Turbine

o MBD GT bearing

o MK - Generator

o MBV GT lubricant
system

Numbering

Major system:

Protection notice / Copyright notice

Page 7

2011-03

E S SF REU 444

Export Classifications
AL:N
ECCN:EAR99

KKS FID
System Identification

21
10

22

30

42
43

20

50

44
51

23

10

52

31

41

30

40

50

Protection notice / Copyright notice

Page 8

2011-03

E S SF REU 444

Export Classifications
AL:N
ECCN:EAR99

KKS FID
System Identification
12

20

11

25

Protection notice / Copyright notice

Page 9

2011-03

E S SF REU 444

Export Classifications
AL:N
ECCN:EAR99

KKS FID
Equipment identification: code of two letters and three numbers

MBP 13 AA 001

component group
A/B = mechanical
component
C = direct measuring
circuit
D

= control loop

= analog and binary


signal conditioning

XB 01

equipment unit code

component code

AA - valve, dampers, etc.


AP - pumps
CE electrical measurement
CF flow measurement
CP pressure measurement, etc.
EC sub group control
(SGC)
EE sub loop control (SLC)
Protection notice / Copyright notice

Page

2011-03

E S SF REU 444

Export Classifications
AL:N
ECCN:EAR99

KKS FID
Equipment identification : component code
valves (AA)
001-100
101-190
191-199
301-399
401-499
501-599
601-699
pipes (BR):

valves in main pipes


control valves
safety valves
shut off valves for measurements
drain valves
vent valves
dosing valves and valves in sampling lines

001-190
191-199
301-399
401-499
501-599
601-699

main pipes
inlet and discharge pipes to safety valves
pipes to pressure measurements
drain lines
vent lines
sampling and dosing lines
Protection notice / Copyright notice

Page

2011-03

E S SF REU 444

Export Classifications
AL:N
ECCN:EAR99

KKS FID

Protection notice / Copyright notice

Page

2011-03

E S SF REU 444

Export Classifications
AL:N
ECCN:EAR99

KKS FID
Equipment identification : component code
measurements (C)
001-199
201-299
401-499
501-599
901-999

binary and analog measurements


for testing automatics
performance test measurements
local measurements
combined measurements

Protection notice / Copyright notice

Page

2011-03

E S SF REU 444

Export Classifications
AL:N
ECCN:EAR99

KKS SID
Signal identification: code of two letters and two numbers

MBP 13 AA

001

_ XB 01

first letter

second letter

X indication of origin

XQ analog signal

Y indication of the usage of


signals.
Multi usage possible.

ZQ linked analog signal

Z indication for linked


signal

Signal number

XS functional group control step signal


XH binary limit signal that is derived
from analog process signal
ZV linked security or alarm signal
YP supervisory control signal
Protection notice / Copyright notice

Page

2011-03

E S SF REU 444

Export Classifications
AL:N
ECCN:EAR99

KKS - SID
Examples
XM20
ZV23

XM20
XM20

Link

X-signals
(origin)

Z-signal
(linked signal)

Protection notice / Copyright notice

Page

2011-03

E S SF REU 444

Export Classifications
AL:N
ECCN:EAR99

KKS SID: Signal number ACTUATOR

XB01

XB51

XB02
XB01 feedback OPEN
XB51 feedback NOT OPEN

XB02 feedback CLOSE


XB52 feedback NOT CLOSE
Protection notice / Copyright notice

Page

2011-03

E S SF REU 444

Export Classifications
AL:N
ECCN:EAR99

KKS SID: Signal number - MOTOR/PUMP


XB01

XB02

XB01 feedback ON
XB51 feedback NOT ON
XB02 feedback OFF
XB52 feedback NOT OFF
Protection notice / Copyright notice

Page

2011-03

E S SF REU 444

Export Classifications
AL:N
ECCN:EAR99

KKS SID: Signal number ASMON

XH01
XH03

XH03 limit value > MAX2


XH53 limit value < MAX2
XH01 limit value > MAX1
XH51 limit value < MAX1
XH52 limit value < MIN1
XH02 limit value > MIN1
XH54 limit value < MIN2
XH04 limit value > MIN1
Protection notice / Copyright notice

Page

2011-03

E S SF REU 444

Export Classifications
AL:N
ECCN:EAR99

KKS SID: Signal number STEP

XS02

XS01 command step 01


XS02 command step 02
XS03 command step 03
XS04 command step 04

Protection notice / Copyright notice

Page

2011-03

E S SF REU 444

Export Classifications
AL:N
ECCN:EAR99

KKS SID: Signal number SERVO


XC01
XC02

XC52
XC11

XC12
XC01 feedback OPEN
XC51 feedback NOT OPEN
XC02 feedback CLOSE

Page

XC52 feedback NOT CLOSE

2011-03

XC11 feedback CLOSED LOOP (CL)


XC12 feedback OPEN LOOP (OL)
Protection notice / Copyright notice
E S SF REU 444

Export Classifications
AL:N
ECCN:EAR99

KKS SID: Signal number CONTINUOUS CONTROL (CCTRL)

XC01
XC02
XC52

XC11

XC12
XC01 feedback OPEN
XC51 feedback NOT OPEN
XC02 feedback CLOSE

Page

XC52 feedback NOT CLOSE

2011-03

XC11 feedback CLOSED LOOP (CL)


XC12 feedback OPEN LOOP (OL)
Protection notice / Copyright notice
E S SF REU 444

Export Classifications
AL:N
ECCN:EAR99

KKS SID: Signal number PRESEL


XA31 preselection SEL1

XA31

XA32 preselection SEL2


XA33 preselection SEL3

XA32

XA34 preselection SEL4

XA33

XA34

Protection notice / Copyright notice

Page

2011-03

E S SF REU 444

Export Classifications
AL:N
ECCN:EAR99

KKS SID: Signal number SLC

XA41

XA42

XA41 SLC ON
XA42 SLC OFF