Flow Chart - Manual Commissioning


Repeater, antenna and cables
are installed

OK
Test VSWR of feeder system

NO

Check connectors
/ cables

Connect the feeder cable to the repeater


and switch on the repeater

OK

OK
Adjust donor antenna
to obtain the excellent signals

NO

Relocate donor
antenna

OK
Test isolation

NO

OK

Adjust or change the


location and type of
the antenna

Set the Repeater UL/DL Gain


based on the previous calculations

OK
Drive/Walk Test
Good

NO

Optimization

OK
Finish

Calculate repeater UL&DL Gain


Based on Output Power and Isolation

OK
2

VSWR Test

Donor Signal Monitoring


GSM

With donor signal monitoring function, it is


easier for user to obtain excellent donor
signal.

Isolation Test
Signal Generator Setting
Frequency: 920MHz (GSM)
1795MHz (DCS)
1995MHz (WCDMA)
Output Power: 25dBm or above
Spectrum Analyzer Setting
Central Frequency: Same with
signal generator
RBW=300KHz
VBW=100KHz

Isolation = Signal Generator Output Power Spectrum Analyzer Measured Value

Isolation Detection

With isolation detection function, user can


obtain isolation value on the repeater
through OMS Lite.

Gain Calculation & Setting - Manually


DL Gain = Required output power
Input power

OK

OK
DL Gain Isolation Value 15 dB

OK

NO

Increase isolation value or


increase input power

NO

Decrease DL Gain to meet


DL Gain Isolation Value 15 dB

OK

UL Gain = DL Gain 5 dB

OK
Set Repeater Gain

OK
Finish
7

Gain Calculation & Setting Example


Assume the Repeaters Input Power = -52dBm;
the Required Output Power = 33dBm
Isolation = 95dB
In this condition, DL Gain = Required Output Power Input Power = 85dB,
So it cannot meet equation: DL Gain Isolation - 15dB

Condition 1:

Adjust the service antenna to increase the isolation to be 100dB,Input power is the
same
DL Gain = Required Output Power Input Power = 85dB
This condition can meet the equation: DL Gain Isolation - 15dB
DL Gain = 85dB, UL Gain = DL Gain - 5dB = 80dB

Condition 2:

Change the donor antenna with higher gain to increase input power to -47dBm
DL Gain = Output Power - Input Power = 80dB
This condition can meet the equation: DL Gain Isolation - 15dB
DL Gain = 80dB, UL Gain = DL Gain - 5dB = 75dB

Condition 3:
Both Isolation and Input power cannot be increased.
DL Gain = Isolation - 15dB = 80dB UL Gain = DL Gain - 5dB = 75dB
Repeater Output Power = -52dBm + 80dB = 28dBm < 33dBm
8

Gain Attenuation Manually


By OMS Lite

Flow Chart - Auto Commissioning


Connect the feeder cable to the repeater
and switch on the repeater

Repeater, antenna and cables


are installed

OK

OK
Test VSWR of feeder system

NO Check connectors
/ cables

OK
NO
Adjust donor antenna
to obtain the excellent signals
OK

Switch ON the Intelligent Mode

OK
Relocate donor
antenna

Drive/Walk Test
Good

NO
Optimization

OK
Finish

10

Gain Settings Intelligent Mode


With the Intelligent Mode function, repeater setting becomes ea
sy.
After repeater is ON, simply switch ON the Intelligent Mode, and
the Intelligent Mode would automatically setup the repeater par
ameters while minimizing possible interference at the same tim
e.
Switch ON Repeater
With the Intelligent Mode function,
Isolation test
Gain calculations
Gain settings
would

No longer be required.

OK

Switch ON Intelligent Mode


OK
Finish
11