CSWIP 3.1
WIS 5
WELDING INSPECTION
PRACTICAL VISUAL
INSPECTION OF PIPE
WELDS
Copyright 2005, TWI Ltd
Page 1 of 3
Name: [Block capitals] Mr. I C Plenty
Code/Specification used: API 1104
Welding process:
MMA/SMAW
140
A
20
15
Lack of side
wall fusion
NOTES:
90
10
B
180
Undercut
60
Under fill
15
Slag
inclusion
Excess weld height : 3mm. Weld width: 12-14mm
Toe blend: Poor. Misalignment: 2mm
Spatter or scale on the pipe surface
Lack of side
wall fusion
Slag
30
46
>1.0
mm
120
22/08/2003
Arc strike
12
40
Date
9
8
Under fill
001
38
Mechanical
Damage
PIPE ROOT
FACE
Lack of root
fusion
140
A
20
15
Lack of root
penetration
NOTES:
90
B
180
10
Root
Undercut
Burn through
6
40
C
60
46
Excess
penetration
5mm
Poor stop
start
>1.0
mm
D
120
38
120
Root Undercut
<1.0mm
I C Plenty
SPECIMEN NUMBER 001
EXTERNAL DEFECTS
Defect Type
Defects Noted
Pipe/Plate
Section
1
Accumulative
Total
2
Maximum
Allowance
3
Section/
Table No
4
Accept/Reject
5
A-A
4mm
1.6mm
7.8.2
Reject
A-A
Poor blend
Smooth
7.8.2
Reject
Incomplete filling
A-A
22mm
None
7.8.2
Accept
A-A
N/A
3mm
7.9.2
Accept
Slag Inclusions
A-A
70mm long
None
7.8.2
Reject
Undercut
A-A
1.5mm depth
0.8mm
9.7.2 Table 4
Reject
Surface Porosity
A-A
1.5mm
2mm
9.3.9.3
Accept
Cracks/Crack-like defects
A-A
40mm
NONE
9.3.10
Reject*
Lack of fusion
A-A
22mm
25mm
9.3
Accept
Arc strikes
A-A
30x25
------------
Not specified
Mechanical damage
A-A
NONE
------------
-----------
Accept
Laps/Laminations
A-A
NONE
------------
-----------
Accept
Misalignment (Linear)
A-A
2mm
3mm
7.2
Accept
A-A
N/A
------------
----------
Accept
Reject**
Root Defects
EXTERNAL DEFECTS
Defects Noted
Defect Type
Pipe/Plate
Section
1
Accumulative
Total
2
Maximum
Allowance
3
Misalignment
A-A
2mm
3mm
A-A
4mm
------------
A-A
50mm
A-A
Root Concavity
Section/
Table No
4
Accept/Reject
5
7.2
Accept
Not
specified
Accept
25mm
9.3.1
Accept
20mm
25mm
9.3.4
Accept
A-A
2mm depth
1mm
9.3.6
Root Undercut
A-A
0.5mm
0.8mm
9.3.11
Accept
Cracks/Crack-like defects
A-A
NONE
------------
9.3.10
Accept
Slag inclusions
A-A
70mm long
None
7.8.2
Reject
Porosity
A-A
1.5mm
2mm
9.3.9.3
Reject
Laps/Laminations
A-A
NONE
------------
----------
Accept
I C Plenty
Signature.........................................................
Date.....................................................................................
*Delete which is not applicable.
Use the other side for any comments.
REMEMBER!
TERMINOLOGY:
Use standard terms.
Do not use abbreviations.
ACCURACY:
All dimensions in millimetres.
No need to scale.
Measurements to be as accurate as
possible.
PRESENTATION:
Sketch to be as neat as possible.
The key to passing the
examination.
Copyright 2005, TWI Ltd
PRACTICAL PIPE.
QUESTIONS ?
1
2
3
4
Internal
alignment
Root gap
dimension
7.8.2
page 20
Misalignment:
7.2 page 19
Reinforcement Appear:
7.8.2
page 20
Longitudinal seams: Not referenced
Incomplete groove:
7.8.2
page 20
Excess penetration: Not referenced
Inadequate weld width:
7.8.2
page 20
Lack of penetration: 9.3.1/9.3.2 page 21
Slag inclusions:
9.3.8
page 22
Lack of root fusion: 9.3.4 page 22
Undercut:
9.3.11 page 24
Concave root:
9.3.6 page 22
Porosity:
9.3.9
page 24
Burn through:
9.3.7 page 22
Cracks:
9.3.10 page 24
Lack of fusion:
9.3.4
page 22
A.5.3
page 55
Mechanical damage:
Not referenced
Lamination:
Not referenced