Rewari-Bahadurgarh Pipeline Section


Frictional
Frictional
Frictional
Frictional

Loss
Loss
Loss
Loss

@
@
@
@

400
440
450
500

cu.
cu.
cu.
cu.

m/hr.:
m/hr.:
m/hr.:
m/hr.:

16
18
19
22

kg/sq.
kg/sq.
kg/sq.
kg/sq.

cm
cm
cm
cm

Minimum Suction Pressure required by Mainline Pumps


at Rewari: 7 kg/sq. cm

BRS BTPL Pumps Key Data


Rated Head: 300 m of HSD i.e. 25 kg/sq. cm
Rated Flow Rate: 385 cu. m/hr.
Discharge Pressure Required @ 400 cu. m/hr.:
Discharge Pressure Required @ 440 cu. m/hr.:
Discharge Pressure Required @ 450 cu. m/hr.:
Discharge Pressure Required @ 500 cu. m/hr.:

22
25
26
29

kg/sq.
kg/sq.
kg/sq.
kg/sq.

Hence, maximum flow rate achievable from BTPL


Pumps is 440 cu. m/hr.

cm
cm
cm
cm

Case-1: BTPL Pumps as Booster Pumps for


RRKPL Pumping
In case FR bypassed to RKPL is greater than 440 cu.
m/hr., BTPL Pumps will act as a bottleneck.
In case FR bypassed to RKPL is around 400-440 cu.
m/hr., BTPL Pumps will aid in reducing RMDS discharge
pressure by 10-15 kg/sq. cm. In such case, FR ex
RMDS can reach up to 800 cu. m/hr. (approx. gain of
50 cu. m/hr.).

Case-2: BTPL Pumps are used for


pumping in RKPL ex BRS
RMDS to BRS can achieve the maximum FR of 800 cu.
m/hr.

FR ex BRS to RKPL can be 400-440 cu. m/hr.

Minimum 3 tanks will be blocked (one each for RBPL,


one for RKPL and the third for Bahadurgarh terminal).

Additional Information Required


Pump Performance Curves are provided for 2400 rpm.
Pump Performance Curves for 3000 rpm are required.
Differential Pressure is assumed as Total Discharge
Pressure (as Maximum Discharge Pressure is not
mentioned in the Data Sheet).
Mechanical Seal is designed for a pressure of 51 kg/sq.
cm. Hence, this does not pose any constraint.
The above additional information will help in
exploring scope for further flow enhancement.