Main Redundancy Features

Optimized for availability of control.


Absolutely no user programming required to implement.
Bumpless switchover guaranteed for any outputs controlled by logic in
the highest priority task.
Switchover within approximately 100 msec.
Works with standard Logix5555 controllers and ControlNet Bridges
(Series D or higher).
Switchovers are transparent to any devices networked to the redundant
controller chassis.

Transparent cross-load of programs from primary to secondary


controllers.

On-line workstation configuration/commands/edits to primary are


automatically forwarded to secondary.

User can choose to cancel or resume test edits at switchover.

Rockwell

Building a Typical Redundant System


Logix5555
RUN

A-B
Quality

Allen-Bradley

ControlNET

RS232
BAT

A#01

REM

Quality

Allen-Bradley

PRI

COM

OK

ControlNET

Start with a standard ControlLogix chassis.


Add 1 or more Logix5555 processors.
Add 1 or more ControlNet Bridges (Series D).
Add 1 System Redundancy Module.
Set up an identical second controller chassis.
Cable the SRMs together.
Add I/O, operator interfaces, and so forth to the
ControlNet network(s).

Redundancy Module

I/O
RS232

BAT

A#01

PRIM

OK
CHA CHB

RUN

OK

PROG

Logix5555
RUN

A-B

PRIM

OK
CHA CHB

RUN

Redundancy Module

I/O

1.
2.
3.
4.
5.
6.
7.

REM

OK

PRI

COM

OK

PROG

Rockwell

Other Redundant Architecture


Considerations

Only Logix5555s, ControlNet Bridges, and a single System


Redundancy Module can be placed in a redundant controller chassis.
All I/O must be remote from the redundant controller chassis.
To connect to other networks, bridge through another ControlLogix
chassis.
Ethernet
A-B
Allen-Bradley

RUN

A-B
Allen-Bradley

RUN

Quality

BAT

Quality

BAT

ControlNET Redundancy Module


Logix
5555 I/O
RS232A#
P
OK
R
01
CHA CHB
OK PRI COM OK
I
RUN REM PROG
M

ControlNET Redundancy Module


Logix
5555 I/O
RS232A#
P
OK
R
01
CHA CHB
OK PRI COM OK
I
RUN REM PROG
M

ControlNet

Rockwell

Logix5555 Controller

New CPU ASIC


Provides alternative memory parity encoding method so
that higher density commercial memory may be used.
New memory change detection algorithms for
Redundancy.

New circuitry to support new 1.5, 3.5, and 7.5 Mbyte


memory cards.
Increased Performance
Faster Flash-Memory to increase operating system
performance.
Movement of Floating Point library to RAM for higher
performance (30% faster than L1).

Hardware changes to support ControlLogix


redundancy.
New Real Time Clock (RTC) chip with increased
accuracy.
In redundancy, data is buffered in the secondary
controller, so twice as much data memory space is
required.

Rockwell

ControlNet allows transparent switchovers


The 1756-CNB Series D has added the necessary
hardware and firmware changes to support
ControlLogix redundancy.
You set the same ControlNet address on the rotary
switches of the primary and secondary CNBs.
The primary CNB will use that address, and the
secondary CNB will automatically use the next
higher address.

On a switchover, the CNBs automatically swap


addresses.
Any external ControlNet devices will simply continue
to communicate with the new primary controller.
ControlLogix redundancy works transparently with
1756 I/O, Flex I/O, drives, operator interfaces, or any
other Rockwell or third-party devices which can
communicate to a Logix5555 over ControlNet.

Rockwell

System Redundancy Module


The 1757-SRM provides the high speed
data transfers between the primary and
secondary chassis and arbitrates
primary/secondary chassis status.
Two slot module
Only one SRM per chassis needed.

Redundancy Module

PRIM
PRI COM

OK

We will test with up to four Logix5555


processors per chassis.

A fiber optic cable connects the primary


and secondary SRMs.
1757-SRC1, SRC3, or SRC10 (1, 3, or 10
meter lengths)

Rockwell

1757-SRM Configuration
The 1757-SRM module will be configured from RSLinx instead of
RSLogix 5000.
Allows one 1757-SRM to support multiple Logix5555 controllers.
Similar to how DHRIO and ENET modules are configured using RSLinx 2.2.

Rockwell

SRM Dialog Module Info Tab


Provides identification of the
module.

Provides the general status of


the module.

1757-SRM REDUNDANCY MODULE

Identifies the
current
redundancy
state of this
chassis. This is
visible from
every tab on the
dialog.

Chassis_B: Primary with Qualified


Secondary

Rockwell

SRM Dialog Configuration Tab


Select when you want a disqualified secondary chassis
to automatically attempt synchronization.
Always
Never
Conditional - Auto-synchronization enabled on
a Synchronize Secondary command and
disabled on a Disqualify Secondary command.

Lets you specify whether this


chassis should be referred to as
Chassis A or Chassis B.

Select whether
programmed messages
from a Logix5555 are
allowed to trigger
redundancy commands
(initiate switchover,
disqualify secondary,
etc.)
Set the date and time
to be used in the
SRM event log.
Chassis_B: Primary with Qualified
Secondary

Rockwell

10

SRM Dialog Synchronization Tab


Issues a manual
command to attempt
to synchronize the
secondary chassis to
make it available for
switchover.

Issues a manual
command to
disqualify the
secondary chassis to
make it unavailable
for switchover.

Issues a manual
command to switch
control to the
secondary chassis.
This can be used to
test the redundant
system.

Issues a manual
command allowing a
disqualified
secondary chassis
with no partner to
take control.

1757-SRM REDUNDANCY MODULE

Shows the result of


the last four
synchronization
attempts of the
redundant system.

Chassis_B: Primary with Qualified


Secondary

Rockwell

11

SRM Dialog Chassis Profile Tab


Shows the current state of all the modules in this redundant
controller chassis.
Shows the
Shows the progress
of synchronization
in percent.

Shows the
secondarys
readiness to take
control.

Shows the state of


the modules
(startup, faulted,
etc).

compatibility
between the
primary and
secondary module.

1757-SRM REDUNDANCY MODULE

Chassis_B: Primary with Qualified


Secondary

Rockwell

12

SRM Dialog Event Log Tab


This dialog shows the history of the past 10 events.
Events that are logged include synchronizations, switchovers, etc.
This information is stored on the SRM module.

1757-SRM REDUNDANCY MODULE

Chassis_B: Primary with Qualified


Secondary

Rockwell

13

No programming required

A primary Logix5555 automatically determines what data changes


during its scan and automatically sends that data to its secondary
Logix5555. You dont have to program messages or even specify
certain data areas to transfer. It all just happens automatically.
You just select a single
checkbox on the
controller properties
dialog to enable
redundancy.

Rockwell

14

Other Controller Properties Options


Allows you to specify whether you want test
edits to remain in effect after a switchover.
This is useful for online edit changes.

This
enables
redundancy.

Lets you specify how much of


the unused memory will be
allocated for adding data online
versus adding program online.

Here you can see the status of this


controller chassis and this
controller.
Here you can see the status of this
controllers redundant partner.

Rockwell

15

Automatic cross-loading of programs


Logix5555
RUN

A-B
Quality

Allen-Bradley

ControlNET

RS232
BAT

A#01

REM

Quality

Allen-Bradley

PRI

COM

OK

ControlNET

Redundancy Module

I/O
RS232

BAT

A#01

PRIM

OK
CHA CHB

RUN

OK

PROG

Logix5555
RUN

A-B

PRIM

OK
CHA CHB

RUN

Redundancy Module

I/O

REM

OK

PRI

COM

OK

PROG

Rockwell

You only have to


download your
program to the
primary controller.
The system will
automatically
cross-load the
primarys program
to the secondary
controller.

16

Bumpless Switchovers
The secondary controller is synchronized with the
primary to provide a bumpless switchover for any
outputs controlled by logic in the highest priority task:
Primary notifies secondary when user tasks start.
Primary notifies secondary when programs complete &
provide a complete data snapshot.
Secondary doesnt execute programs, but follows along, pending
at each program start.
Incomplete transfers are quarantined on secondary until
complete.

At switchover, the new primary rolls back to the beginning


of currently executing programs using last good data
snapshot.

Rockwell

17

ControlLogix Redundant Power Supply


1756-PA75R / -PB75R
Power Supplies
85 - 265 VAC and 19 - 32 VDC
Versions
Panel mount (1756-A4 footprint 6.9" H x 5.7" W x 5.4" D)
Px75 equivalent capacity

1756-CPR Cables
3 foot max length
Pin-outs provided if you want to
make shorter cables

1756-PSCA
Chassis Adapter Module
Passive device funnels power
to backplane
Series B chassis only

Failure Annunciation
Normally Open solid state relay on each supply
Wire to any input module