Вы находитесь на странице: 1из 268

Leading in the

compute era
Delivering the right compute, for the right workload, at the right economics
every time.

Channel Technical Deck v1.0 19th September 2014

Copyright 2014 Hewlett-Packard Development Company, L.P. The information contained herein is subject to change without notice.
Confidentiality Notice
The information contained in this presentation is
proprietary to Hewlett-Packard Company and is
offered in confidence, subject to the terms and
conditions of a Non-Disclosure Agreement.
This document is NOT to be used as a
leave behind; and therefore, may not be
externally distributed in either printed or
electronic format.
The information contained is to be handled
accordingly with HPs policy for handling this
classification of information.
HP makes no warranties regarding the accuracy
of this information. HP does not warrant or
represent that it will introduce any product to
which the information relates. It is presented for
evaluation by the recipient and to assist HP on
Copyright 2014 Hewlett-Packard Development Company, L.P. The information contained herein is subject to change without notice. Authorised HP Channel
2
defining
Partners Only
product direction.
The company that
Reimagine
brought you
introduces the
you the
server.
tofirst Think
the next 25.
25 years of
compute.
enterprise
computing
Copyright 2014 Hewlett-Packard Development Company, L.P. The information contained herein is subject to change without notice.
Gen9 Product Lineup at
launch

Copyright 2014 Hewlett-Packard Development Company, L.P. The information contained herein is subject to change without notice.
URLs

Marketing Library hp.com press on the bottom of the page


Data Sheet
QuickSpecs
Technical White Paper
FAQ/Q&A
Benchmark and performance guide Benchmarks
White Paper
Analyst report
Brochure

OS Support - www.hp.com/go/ossupport

5
Copyright 2014 Hewlett-Packard Development Company, L.P. The information contained herein is subject to change without notice. Authorised HP Channel
Partners Only
HP ProLiant Gen9 Series At Launch
Delivering new levels of performance and user experience for HP
ProLiant servers

DL160 DL360
Right sized Dense performance
performance and for multi-workload
storage density for computes in the
datacenter BL460c
space and budget
constrained Ideal balance
environments ML350 of
performance,
HPs best all-in-one scalability,
server with and
DL180 DL380 maximum expandability
THE no-compromise expandability,
The new standard for
datacenter standard serviceabilityand
growing datacenter
for multi-workload reliability
needs
compute

6
Copyright 2014 Hewlett-Packard Development Company, L.P. The information contained herein is subject to change without notice. Authorised HP Channel
Partners Only
HP ProLiant Gen9 Rack and Tower
Portfolio
Delivering Series
new levels of performance and user experience for HP
ProLiant servers
100 series 300 series
Optimized with the THE industry-
right balance of standard, tailored
storage, with flexible choices
performance, for compute
efficiency and intensive
manageability workloads
to address requiring high
multiple system
workloads for performance,
growing manageability,
expansion and
security for

SMB, Enterprise and


7
SMB
Copyright 2014 Hewlett-Packard Development and
Company, L.P. Enterprise HPC
The information contained herein businesses
is subject to change without notice. Authorised HP Channel
Partners Only
A
Gen9 portfolio interline positioning
D
N

guidance
Feature New IT Growth (100
series)
Traditional IT (300
series)
Chassis Reduced depth (<24) Standard depth
Processor supported Limited stack (up to 105w) Full stack (up to 145w)
Memory Upto 16 DDR4 DIMM slots Upto 24 DDR4 DIMM slots
PCI-e slots Few Maximum
Networking 2x1Gb embedded + 4x1Gb embedded,
optional Flexible LOM on riser Flexible LOM optional
Storage controller Embedded SATA with optional Embedded SATA with
PCI-e Smart Array / HBA Cards optional Smart Array AROC
and PCI-e
Drive expansion Medium-High Maximum
Express Bay support No Supported
GPU support Limited Maximum
Power supply Non common slot with NHP and Flex slot hot plug only
HP redundant options
Cooling Hot-swap / non-redundant fans Hot plug redundant fans
w/ optional redundancy
Warranty 3 year limited (3-1-1) 3 years (3-3-3)

8
Copyright 2014 Hewlett-Packard Development Company, L.P. The information contained herein is subject to change without notice. Authorised HP Channel
Partners Only
1S/2S 1U Comparison
DL160 DL360
2 x Intel Xeon E5-2600v3 up to 2 x Intel Xeon E5-2600v3 up to
Processor
105W 145W
16xDDR4 DIMM slots up to 2133 24xDDR4 DIMM slots up to 2133
Memory
MHz MHz, Persistent memory future
Up to 3 PCIe 3.0 slots
CPU1: 1x16 Gen3 FHHL, 1x8 Gen3
PCIe 3.0 Low Profile or 1X8 Gen3 FHHL, 1X8
Up to 3 PCIe 3.0 slots
slots Gen 3 low Profile ( FlexibleLOM
enablement riser card )
CPU2: 1x16 Gen3 Low Profile
2x1Gb embedded NIC (optional 4x1Gb embedded, x8 FlexibleLOM
Network
FlexibleLOM on riser) optional
Standard 10 ports of Intel SATA RAID Standard 10 ports of Intel SATA
Storage
(B140i) and SAS via PCIe stand up RAID (B140i) and AROC (x8 PCIe
Controller
card 3.0) for SAS
LFF chassis: LFF Chassis:
SAS/SATA 4LFF NHP, 4LFF HP 4LFF HP
Drives SFF Chassis SFF Chassis
8SFF 8SFF, 10SFF (8+2)
GPU
None Single-Wide Active only
support
Power Non CS 550w 85% non-redundant Next Gen FlexSlot PS Hot Plug
Supply NHP, Optional 900W 94% HP RPS with redundancy optional
Hot swap fan with optional
Fan Hot plug redundant fan
redundancy
Internal
Optional Optional
ODD
Mid-Tier iLO,
9 Mgmt Optional upgrade to dedicated iLO Enterprise Tier iLO
Copyright 2014 Hewlett-Packard Development Company, L.P. The information contained herein is subject to change without notice. Authorised HP Channel
NIC port
Partners Only
N
D
A 2S 2U Comparison
DL180 DL380
Processor 2 x Intel Xeon E5-2600v3 up to 105W 2 x Intel Xeon E5-2600v3 up to 145W
24xDDR4 DIMM slots up to 2133 MHz,
Memory 16xDDR4 DIMM slots up to 2133 MHz
Persistent memory future
Up to 6 PCIe 3.0 slots
CPU1: 1 FHFL(x16 Gen3, 1FHHL(x8 Gen3) or 3
FHHL(x8 Gen3) or 2 FHHL(x8 Gen3) +
PCIe 3.0
FlexibleLOM Up to 6 PCIe 3.0 slots
slots
CPU2: 1 FHFL(x16 Gen3)+1FHHL(x8 Gen3) or 3
FHHL(x8 Gen3) or 2 FHHL(x8 Gen3) +
FlexibleLOM)
2x1Gb embedded NIC (optional FlexibleLOM on
Network 4x1Gb embedded, x8 FlexibleLOM optional
riser)
Storage Standard 10 ports of Intel SATA RAID (B140i) Standard 10 ports of Intel SATA RAID (B140i)
Controller and SAS via PCIe stand up card and AROC (x8 PCIe 3.0) for SAS
LFF Chassis:
LFF chassis:
4/12LFF HP
4/8LFF NHP, 8/12LFF HP
SAS/SATA SFF Chassis:
SFF Chassis:
Drives 8SFF, 16SFF (8+8), 24SFF (8+8+8)
8SFF, 16SFF (8+8)
Rear Drive:
2 SFF / 3 LFF (only with 12 LFF or 24 SFF)
GPU Single/Double-Wide & Active/Passive up to
Single-Wide Active only
support 10.5
Power Non CS 550w 85% non-redundant NHP, Optional Next Gen FlexSlot PS Hot Plug with
Supply 900w 94% HP RPS redundancy optional
Fan Hot swap fan with optional redundancy Hot plug redundant fan
Internal
Optional with SFF, not supported for LFF Yes with , 8SFF, not supported for LFF
ODD
Mid-Tier iLO , Optional upgrade to dedicated iLO
Mgmt Enterprise Tier iLO
10 NIC port
Copyright 2014 Hewlett-Packard Development Company, L.P. The information contained herein is subject to change without notice. Authorised HP Channel
Partners
Express bay Only
Not offered PCIe add-on card solution in the Future
ProLiant Gen9 platforms,
terms, definitions, related
quants, technologies

Copyright 2014 Hewlett-Packard Development Company, L.P. The information contained herein is subject to change without notice.
Platform Technology
Details

Copyright 2014 Hewlett-Packard Development Company, L.P. The information contained herein is subject to change without notice.
New/improved technologies Gen to Gen
compare
Storage Flexible
Choice
Blue
text
indicat
Gen8 Gen8 es new
Gen9 Gen9
for
6 Gb/s Smart Array Controllers 12Gb/s Smart Array Controllers HP FlexibleLOM Gen9
Embedded/Flexible LOM Select
6 Gb/s HBA 12Gb/s Smart HBA HP Flexible Capacity Racks
6Gb SAS SSD; 6GB SATA 12Gb/s SAS HDD/SSD New rack and tower HP Flexible Capacity
HDD/SSD PCIe Workload Accelerators platforms DL360e, New rack and tower platforms
PCIe I/O Accelerators HP SmartCache SSD DL380e DL180, DL160
HP SmartCache with SSD HP StoreVirtual VSA with UEFI/Legacy BIOS
HP StoreVirtual VSA Intelligent Provisiong Universal Media Bay
12Gb/s SAS Expander Card HP Flexible Smart Array
HP Smart Storage Battery

Memory Services

Gen8 Gen9 Gen8 Gen9

HP DDR3 HP DDR4 HP Technology Services HP Technology Services


SmartMemory SmartMemory HP Care Pack Services HP Care Pack Services
(1333-1866 MHz) supports up to 2133 HP Proactive Care HP Proactive Care
UDIMM/RDIMM/LRD MHz RDIMM/LRDIMM Services Services
IMM
13
Copyright 2014 Hewlett-Packard Development Company, L.P. The information contained herein is subject to change without notice. Authorised HP Channel
Partners Only
Blue
text

New/improved technologies Gen to Gen indicat


es new
for
compare
Networki
ng
Management Gen9

Gen8 Gen9 Gen8 Gen9


10Gb FlexFabric 20Gb FlexFabric adapters HP OneView blades only HP OneView 1.X
adapters BL only HP SUM 5.0 blades/rack
1Gb/10Gb Ethernet 1Gb/10Gb/40Gb Ethernet HP iLO 4 v1.00 HP SUM 7.1.0 with iLO
QDR/FDR Infiniband FDR InfiniBand HP Serv for ProLiant (SPP) Federation
6125 XLG Blade Embedded 1GbE LOM on DL Intelligent Provisioning HP iLO 4 v2 .00
Switch racks HP Insight Online HP SPP 2014.09.00
HP FlexibleLOM Tunnel Offload HP Insight Control Intelligent Provisioning v2.0
RDMA over Conv Ethernet UEFI BIOS (DL580 Gen8 only) HP Insight Online
(RoCE) HP Insight Control
4x improvement in small UEFI BIOS (default all Gen9)
Security packet performance Power & HP RESTful Interface Tool

Cooling
Gen8 Gen9 Gen8 Gen9

Serviceguard for Serviceguard for Linux Common Slot Power Common Slot Power Supplies
Linux HP Secure Encryption Supplies Ltd.
HP Secure UEFI Secure Boot ASHRAE A1/A2 support ASHRAE A3/A4 support
Encryption HP UPS HP UPS
Location Discovery Services Location Discovery Services
HP Rack Mount PDUs HP Rack Mount PDUs
Power Discovery Services Power Discovery Services
The information contained herein is subject to change without notice. Authorised HP
Flexible Channel
14 Slot Power Supplies
Copyright 2014 Hewlett-Packard Development Company, L.P.
Partners Only
New or improved
technologies or
innovations, options

Copyright 2014 Hewlett-Packard Development Company, L.P. The information contained herein is subject to change without notice.
HP ProLiant Gen9 building on ProLiant Gen8
innovations
In ProLiant Gen8, HP introduced the Worlds Most Intelligent Servers
with over 150 customer-inspired innovations. also included in
most ProLiant Gen9 platforms

HP SmartMemory Advancements in iLO Management Thermal Discovery


technology Engine Services
HP Smart Carriers for PCIe 3.0 Support HP FlexibleLOM Service Pack for
HDD ProLiant
Solid State HP SUM eliminating HP SmartCache HP Intelligent Serviceability
Optimized Drives setup CDs Provisioning Enhancements
HP Smart Socket
HP Active HealthClear Air Baffles Guide New Smart Array
technology HP Secure controllers with FBWC
Power Discovery Encryption only
PCIe I/O Accelerators
Services Location Discovery Common Slot Power
Services Supplies
16
Copyright 2014 Hewlett-Packard Development Company, L.P. The information contained herein is subject to change without notice. Authorised HP Channel
Partners Only
Intel E5-2600v3
CPU

Copyright 2014 Hewlett-Packard Development Company, L.P. The information contained herein is subject to change without notice.
Available

Intel Xeon E5-2600 v3 Series


Description Is What is Does What it Means Customer Associated Quants/Claims
the new, does function value statement,
unique benefit
differentiator
Intel Xeon E5- Next Generation All ProLiant Gen9 Increase compute Up to 70% increase in
2600 v3 Series of Intel Snap1 servers have performance across workload performance with
performance Intel Xeon E5- multiple workloads by Intel AVX 2
processors 2600 v3 Series combining HP ProLiant Up to 36% increase in power
innovations with Intel efficiency with smarter
Next-Gen EP processors power cores with Per Core P-
States (PCPS)
Enabling virtualization
orchestration with Cache QoS
monitoring
DDR4 memory support
Up to 50% increased
bandwidth with 3DPC
Up to 50% increased
power efficiency
With DDR4 you can
support higher memory
bandwidth with lower
density DIMMs; Overall
platform price impact is
minimal even assuming a
The information contained herein is subject to change without notice. Authorised HP Channel
18
Copyright 2014 Hewlett-Packard Development Company, L.P.
30% premium for DDR4
Partners Only
Processor Changes (ML/DL300 series &
BL460c) Gen8 Gen9
Ivy Bridge / E5- Haswell / E5-2600
2600 v2 v3
Wattage Up to 135W Up to 145W
Cores Counts Up to 12 Up to 18
Cache Size 2.5MB per core 2.5MB per core
DDR Speed Up to 1866 DDR3 Up to 2133 DDR4
DDR Sockets Up to 24 (16 on BL) Up to 24 (16 on BL)
Technology 22nm 22nm

QPI Up to 8 GT/s Up to 9.6 GT/s


PCIe
19
40x PCIe 3.0 40x PCIe 3.0Authorised HP Channel
Copyright 2014 Hewlett-Packard Development Company, L.P. The information contained herein is subject to change without notice.
Partners Only
Processor Changes (DL160/DL180
series) Gen8 Gen9
Ivy Bridge / E5- Haswell / E5-2600
2400 v2 v3
Wattage Up to 95W Up to 105W
Cores Up to 10 Up to 12
Counts
Cache Size 2.5MB per core 2.5MB per core
DDR Speed Up to 1600 DDR3 Up to 2133 DDR4
DDR Sockets Up to 12 Up to 16
Technology 22nm 22nm

QPI
20 Up to 8 GT/s Up to 9.6 GT/s
Authorised HP Channel
Copyright 2014 Hewlett-Packard Development Company, L.P. The information contained herein is subject to change without notice.
Partners Only
Intel E5-2600 Processor: Performance
Projections
Gen8 Ivy Bridge: ~33% over
Sandy Bridge
Higher core count (10 -> 12)
Higher memory speed (DDR3
1866)

Haswell
Haswell
Ivy
Ivy Bridge

Gen9 Haswell: ~40% over Ivy


Bridge
Bridge
Sandy
Bridge
Sandy

Bridge
New IA micro Architecture
Higher core count (12 > 18)
Higher QPI speed (8.0 -> 9.6 GT/s)
21
Higher memory speedHP(DDR4
Authorised Channel
Copyright 2014 Hewlett-Packard Development Company, L.P. The information contained herein is subject to change without notice.
Partners Only
E5-2600v2 to E5-2600v3 in EURO
Xeon E5-2600 v2 Socket R IvyBridge (Aug. 2014 Xeon E5-2600 v3 Socket R Haswell (Aug. 2014
Pricing) Pricing)

Price
Performanc SPECint_rat
Processor Freq Cores WATTs DL380p Difference Processor Freq Cores WATTs DL380p
SPECint_rate e Gain e
HSW to IVB
Estimates
E5-2690 V2 3.0 10 130 2,300 871 22% 5% E5-2690 v3 2.6 12 135 $ 2,425 1059
E5-2680 V2 2.8 10 115 1,950 830 21% 3% E5-2680 v3 2.5 12 120 2,010 1005
E5-2670 V2 2.5 10 115 1,750 787 22% 5% E5-2670 v3 2.3 12 120 1,830 960
E5-2660 V2 2.2 10 95 1,550 722 21% 3% E5-2660 v3 2.6 10 105 1,590 873
E5-2650 V2 2.6 8 95 1,280 663 23% 2% E5-2650 v3 2.3 10 105 1,310 817

E5-2640 V2 2.0 8 95 985 524 33% 11% E5-2640 v3 2.6 8 90 1,090 695


E5-2630 V2 2.6 6 80 750 489 35% 8% E5-2630 v3 2.4 8 85 810 661


E5-2620 V2 2.1 6 80 550 417 20% 5% E5-2620 v3 2.4 6 85 575 502


E5-2609 V2 2.5 4 80 385 242 21% 9% E5-2609 v3 1.9 6 85 420 293


E5-2603 V2 1.8 4 80 265 180 48% 17% E5-2603 v3 1.6 6 85 310 266

35% 72% E5-2699 v3 2.3 18 145 5,250 1272


27% 34% E5-2698 v3 2.3 16 135 4,100 1195
E5-2697 V2 2.7 12 130 3,050 942 26% 7% E5-2697 v3 2.6 14 145 3,250 1191
E5-2695 V2 2.4 12 115 2,650 890 22% 6% E5-2695 v3 2.3 14 120 2,800 1082
E5-2683 v3 2.0 14 120 2,125 1055
E5-2667 V2 3.3 8 130 2,350 779 2% 2% E5-2667 v3 3.2 8 135 2,390 797
E5-2643 V2 3.5 6 130 1,860 617 7% 1% E5-2643 v3 3.4 6 135 1,875 661
E5-2637
22 V2 3.5 4 130 1,200 415 9% 1% E5-2637 v3 3.5 4 135 1,210 454
Copyright 2014 Hewlett-Packard Development Company, L.P. The information contained herein is subject to change without notice. Authorised HP Channel
-
Partners Only
E5-2400v2 to E5-2600v3 in EURO

Xeon E5-2400v2 IvyBridge (Aug. 2014 Pricing) Xeon E5-2600v3 Haswell (Aug. 2014 Pricing)

Price
Core Performan Core SPECint_ra
Processor Freq WATTs DL380e SPECint_ra Difference Processor Freq WATTs DL180
s ce Gain s te
te HSW to IBV
Estimates
E5-2470 E5-2660

v2 2.4 10 95 1,650 712 23% -4% v3 2.6 10 105 1,590 873
E5-2450 E5-2650

v2 2.5 8 95 1,190 609 34% 10% v3 2.3 10 105 1,310 817
E5-2440 E5-2640
v2 1.9 8 95 985 492 41% 11% v3 2.6 8 90 1,090 695
E5-2430 E5-2630

v2 2.5 6 80 675 463 43% 20% v3 2.4 8 85 810 661
E5-2420 E5-2620

v2 2.2 6 80 515 421 19% 12% v3 2.4 6 85 575 502
E5-2407 E5-2609

v2 2.4 4 80 315 231 27% 33% v3 1.9 6 85 420 293
E5-2403 E5-2603

v2 1.8 4 80 260 179 49% 19% v3 1.6 6 85 310 266

E5-2450L E5-2650L
23
Copyright 2014 Hewlett-Packard Development Company, L.P. The information contained herein is subject to change without notice.
v2 1.7 10 60 1,325 531 37% 15% v3 1.8
Authorised
12 65
HP Channel
1,525 726
Partners Only
E5-2600v2 to E5-2600v3 in USD
Xeon E5-2600 v2 Socket R IvyBridge (Aug. 2014 Xeon E5-2600 v3 Socket R Haswell (NTE Aug. 2014
Pricing) Pricing)

Price
Core Performanc SPECint_rat
Processor Freq WATTs DL380p SPECint_rat Difference Processor Freq Cores WATTs DL380p
s e Gain e
e HSW to IVB
Estimates
$ $

E5-2690 V2 3.0 10 130 3,150 871 22% 3% E5-2690 v3 2.6 12 135 3,250 1059
$ $

E5-2680 V2 2.8 10 115 2,670 830 21% 1% E5-2680 v3 2.5 12 120 2,695 1005
$ $

E5-2670 V2 2.5 10 115 2,400 787 22% 2% E5-2670 v3 2.3 12 120 2,450 960
$ $

E5-2660 V2 2.2 10 95 2,075 722 21% 3% E5-2660 v3 2.6 10 105 2,130 873
$ $

E5-2650 V2 2.6 8 95 1,715 663 23% 2% E5-2650 v3 2.3 10 105 1,755 817
$ $
E5-2640 V2 2.0 8 95 1,350 524 33% 8% E5-2640 v3 2.6 8 90 1,460 695
$ $

E5-2630 V2 2.6 6 80 1,005 489 35% 8% E5-2630 v3 2.4 8 85 1,085 661
$ $

E5-2620 V2 2.1 6 80 735 417 20% 5% E5-2620 v3 2.4 6 85 770 502
$ $

E5-2609 V2 2.5 4 80 515 242 21% 10% E5-2609 v3 1.9 6 85 565 293
$ $

E5-2603 V2 1.8 4 80 360 180 48% 15% E5-2603 v3 1.6 6 85 415 266

$
E5-2699 v3 2.3 18 145
35% 67% 7,035 1272
16Authorised
24
Copyright 2014 Hewlett-Packard Development Company, L.P. The information contained herein is subject E5-2698
to change v3
without $ HP Channel
2.3notice. 135
27% 31% 5,495 1195
Partners Only
Intel Xeon E5-2600 v
Intel Xeon E5-2600 v
Fre Core WATT
Processor
q s s
DL380
5250 46% 1272
4100 p 1195
E5-2699 v3 2.3 18 145 3250
5,250 1191
E5-2698 v3 2.3 16 135 3050
4,100 942
E5-2697 v3 2.6 14 145 2800
3,250 22% 1082
E5-2697 v2 2.7 12 130 2650
3,050
890
E5-2695 v3 2.3 14 120 2,800
2425 -20% 12% 22% 1059
E5-2695 v2 2.4 12 115 2,650
2390 797
E5-2690 v3 2.6 12 135 2,425
E5-2667 v3 3.2 8
2350
135 2,390
779
E5-2667 v2 3.3 8
2300
130 2,350 871
130 2125 1055
E5-2690 v2 3.0
E5-2683 v3 2.0
10
14
2,300
120 2010
2,125
-13% 15% 21% 1005
E5-2680 v3 2.5 12 120 1950
2,010 830
E5-2680 v2 2.8 10 115 1875
1,950 661
E5-2643 v3 3.4 6 135 1860
1,875 617
E5-2643 v2 3.5 6 130 1830
1,860 -31% 8% 22% 960
E5-2670 v3 2.3 12 120 1750
1,830 787
E5-2670 v2 2.5 10 115 1590
1,750 -9% 11% 21% 873
E5-2660 v3 2.6 10 105 1550
1,590 722
E5-2660 v2 2.2 10 95 1525
1,550 726
E5-2650L v3 1.8 12 65 1380
1,525
546
E5-2650L v2 1.7 10 70 1,380
1310 -15% 13% 23% 817
E5-2650 v3 2.3 10 105 1,310
E5-2650 v2 2.6 8 95
1280
1,280
663
E5-2637 v3 3.5 4
1210
135 1,210 454
130 1200 415
E5-2637 v2 3.5 4 1,200 -15% 5% 33% 695
E5-2640 v3 2.6 8 90 1090
1,090
E5-2640 v2 2.0 8 95 985 985 524 Price sensitive
E5-2630 v3 2.4 8 85 810 810
-18% 26% 661 customers
E5-2630 v2 2.6 6 80 750 750 489 Price Perf.
E5-2630L v2 2.4 6 60 740 740 445
E5-2630L v3 1.8 8 55 735 735
-23% 3% 20% 514 Performance sensitive
E5-2620 v3 2.4 6 85 575 575 502
E5-2620 v2 2.1 6 80 550 550 417
customers
E5-2609 v3 1.9 6 85 420 420 21% 293
Perf.
E5-2609 v2 2.5 4 80 385 385 242
E5-2603 v3 1.6 6 85 310 310 48% 266
E5-2603 v2 1.8 4 80 265 SPECint*rate_base2006 Score
Development180
Company, L.P. The information contained herein is subject to change without notice. Authorised HP Channel
25 265
E5-2623
v3Copyright
3.0 42014105
Hewlett-Packard
0
0 414
Partners Only
Intel Xeon E5-2600
Intel Xeon E5-2600
Fre Core WATT
Processor DL380
q s s 7035
p
46% 1272
5495 1195
$
E5-2699 v3 2.3 18 145 4355
7,035
1191
4210
$ 942
E5-2698 v3 2.3 16 135 3750
5,495 22% 1082
3660 $ 890
E5-2697 v3 2.6 14 145 3250
4,355 -23% 12% 22% 1059
3205 $ 797
E5-2697 v2 2.7 12 130 3150
4,210 871
3150 $ 779
E5-2695 v3 2.3 14 120 3,750
2850 1055
E5-2695 v2 2.4 12 115 2695
$
3,660
-14% 15% 21% 1005
2670 $ 830
E5-2690 v3 2.6 12 135 2515
3,250 661
2490 $ 617
E5-2667 v3 3.2 8 135 2450
3,205 -33% 8% 22% 960
2400 $ 787
E5-2690 v2 3.0 10 130 2130
3,150 -11% 11% 21% 873
$
E5-2667 v2 3.3 8 130
2075
3,150 722
2045
$ 726
E5-2683 v3 2.0 14 120 1850
2,850 546
1755 $ -15% 13% 23% 817
E5-2680 v3 2.5 12 120 1715
2,695 663
1620 $ 454
E5-2680 v2 2.8 10 115 1610
2,670 415
E5-2643 v3 3.4 6 135
1460
$
2,515
-15% 5% 33% 695
1350
$
524 Price sensitive
E5-2643 v2 3.5 6 130 1085
2,490 -20% 26% 661
customers
1005 $ 489
E5-2670 v3 2.3 12 120 9902,450 445
Price Perf.
985 $ 514
E5-2670 v2 2.5 10 115 7702,400 -23% 3% 20% 502
Performance sensitive
735 $ 417 customers
E5-2660 v3 2.6 10 105 2,130 Perf.
730 414
E5-2660 v2 2.2 10 95
565
$
2,075
21% 293
515 $ 242
E5-2650L v3 1.8 12 65 415 2,045 266
26
Copyright 2014 Hewlett-Packard
360 $ Development180 SPECint*rate_base2006 Score
Company, L.P. The information contained herein is subject to change without notice. Authorised HP Channel
E5-2650LPartners
v2 1.7 10 Only
70 1,850
Intel Xeon Processor E5-2600 v3
Product Family Preliminary
SPECCPU*rate_base2006 Performance

27
Copyright 2014 Hewlett-Packard Development Company, L.P. The information contained herein is subject to change without notice. Authorised HP Channel
Partners Only
Memory

Copyright 2014 Hewlett-Packard Development Company, L.P. The information contained herein is subject to change without notice.
Available

HP DDR4 SmartMemory
Description Is What is Does What it Means Customer Associated Quants/Claims
the new, does function value statement,
unique benefit
differentiator
Unique DDR4 Smart Improve memory Better Compute HP DDR4 SmartMemory
technology that Memory performance and performance. (32GB) priced at parity
unlocks certain authentication Faster application access. with HP DDR3 SmartMemory
features only Lower power (32GB)
available on HP consumption. Up to 14% better memory
Qualified memory performance ProLiant
and ProLiant G9 Rack and Tower
systems will also Up to 33% better memory
be able to reliably performance ProLiant
identify and Blade Servers
verify. HP DDR4 SmartMemory
improves power consumption
by 37% vs. HP DDR3
SmartMemory
Deliver best price/GB with
the best industry
performance.

29
Copyright 2014 Hewlett-Packard Development Company, L.P. The information contained herein is subject to change without notice. Authorised HP Channel
Partners Only
HP SmartMemory
Industry transition to DDR4 Adding value with HP innovation
Gen9 unique technology unlocks certain features only
available on HP Qualified memory including the ability to
reliably identify and verify.
Ideal for customers who want assurance of buying genuine
HP qualified memory, optimized on HP ProLiant and
capable of enhanced support through HP Active Health
Higher Performance *
System. Power Saving
+14% throughput at DDR4- /efficiency
2133 (16-slot servers) 37% lower power
+9% throughput at DDR4- consumption than 1.5V
2133 (24-slot servers) DDR3 at the same speed
Expecting 1% reduction in bin
memory related Outages 20% lower power at 1.35V
4X memory capacity DDR3 at the same speed
increase. bin
* When compared to 1866 DDR3 Closer DDR4 DIMM spacing
allows bigger/cheaper CPU NO Low Voltage DIMMs
heat-sink anymore
30
Copyright 2014 Hewlett-Packard Development Company, L.P.
TheLower fan power and better all modules
information contained herein is subject to change without notice. running
Authorised at 1.2V
HP Channel
Partners Only acoustics and
Dynamic workload acceleration extends
performance
HP SmartMemory optimized for HP ProLiant

DDR4-2133 RDIMM and DDR4-2133 LRDIMM


LRDIMM
(2 DIMMs per channel) (3 DIMMs per channel)

2133
1866
HP SmartMemory 1600 1600
Third Party Memory

31
Copyright 2014 Hewlett-Packard Development Company, L.P. The information contained herein is subject to change without notice. Authorised HP Channel
Partners Only
DDR4 part number description format

HP ggggg eRxff DDR4 wwwwm a bb-ccd Kit


DIMM Type
R = Registered
Capacity Rank Memory Type Module Bandwidth L = Load Reduced
4GB 1R = single 17000MT/s (DDR4-2133)
8GB 2R = dual Special Descriptor
16GB 4R = quad (If Needed)
32GB Data Width CAS Latency HS = Heat spreader
64GB x8 = 8 P = 15-15-15
x4 = 4

Above format becomes; HP 8GB 1Rx4 DDR4-2133P-R Kit

32
Copyright 2014 Hewlett-Packard Development Company, L.P. The information contained herein is subject to change without notice. Authorised HP Channel
Partners Only
Storage

Copyright 2014 Hewlett-Packard Development Company, L.P. The information contained herein is subject to change without notice.
ProLiant Gen9 Smart Storage Enhancements
and flexible
More Changes direct attached storage offer across sever
portfolio
All servers offer SATA only option (up to 10 ports)
All servers offer SATA B140i (new on DL380/DL360/ML350/BL460c)
New options for boot device coming (after initial launch)
M. 2 SATA, USB attached mirrored microSD
No embedded Smart Array controllers (new optional daughter cards)
New 12 Gib SAS P-series controllers
Px4x across the server portfolio (previous generations not supported in Gen9)
Shared battery for backup power (no more supercaps)
Single cache module across stand up cards (4 Gib)
New 12 Gib SAS H-series controllers
Shared ASIC, FW, Drivers with P-series
New low cost SAS RAID option (0, 1,5)

34
Copyright 2014 Hewlett-Packard Development Company, L.P. The information contained herein is subject to change without notice. Authorised HP Channel
Partners Only
ProLiant Gen9 Smart Storage Enhancements
and Changes
Moved from embedded RAID controller to optional daughter
card
P440ar, H240ar supported on the DL380, DL360, ML350
P244br, H244br supported on the BL460
Cache not replaceable, upgradable, or transferable on
AROC/BROC only
All internal backplanes support 12Gib SAS
12Gib SSDs and 15K SAS HDDs
No 12Gib SAS switch planned for C-Class
Standalone SAS expander support for ML/DL
Supported external JBODS
D2600, D2700, D6000, D3600, D3700
UEFI
Boot volumes over 2.2TB in size
35 Over 4 disk partitions supported
Copyright 2014 Hewlett-Packard Development Company, L.P. The information contained herein is subject to change without notice. Authorised HP Channel
Partners Only
P-Series Controllers Enhancements

Support for user configurable power mode


Maximum Performance default, no power savings
Minimum Power maximum power savings, potential significant impact on
performance
Balanced optimal settings based on configuration, minimal performance
impact
Smart Cache
New write-back capability for improved write performance
Critical for many application such as VDI
RAID 0, 1, 5 support for cache LUN
Added RAID 1 support for cache LUN in write through mode
Seamless encryption support, enabled transformation for non-cache volumes
HBA mode
36
Copyright 2014 Hewlett-Packard Development Company, L.P. The information contained herein is subject to change without notice. Authorised HP Channel
Partners Only
Available

HP 12Gb/s Smart Array Controllers


Description Is What is the Does What it Means Customer Associated Quants/Claims
new, unique does function value statement,
differentiator benefit
Controller that 12 Gb/s SAS; Improve storage Address data explosion Support max of 576 TB
provides SAS Flexible Smart Array performance, by being able to manage behind the Smart Array
connection to form factor minimize the data capacity controller
direct attach downtime and growth, provide faster Support 1M IOPS
storage and to service access to information Rapid rebuild of drives
shared storage interruptions especially for businesses Power efficiency reduces
dealing with digital TCO especially when fewer
content, smart devices, drives are used in the
social media, web-based infrastructure (e.g. Blade
and real-time servers and a SAN as the
transactions, minimize backend storage)
downtime, or prevent Non-disruptive flashing of
data loss SAS drives (available in snap
2), there is no need to reboot
the server after firmware
updates thereby minimizing
downtime associated with
maintenance

37
Copyright 2014 Hewlett-Packard Development Company, L.P. The information contained herein is subject to change without notice. Authorised HP Channel
Partners Only
Storage Controllers
P440ar
Modular storage on 300-series
6Gb SATA Smart Storage Battery
6Gb/12Gb Smart Array

SATA storage on 10/100-series with optional PCIe slot


controller offerings
HP Smart Storage battery backs up all internal storage
controllers & NVDIMM P440

Type Port Cache Connecto


s r
B140i Embedded 10 No 2 x4 / 2 x1
SATA
P840
P440ar Smart Array 8 2GB soldered 2 x4
SAS down

P440 Smart Array 8 4GB 1 x8


38
SAS
Copyright 2014 Hewlett-Packard Development Company, L.P. The information contained herein is subject to change without notice. Authorised HP Channel
Partners Only
HP Dynamic Smart Array B140i
controller
Product overview:
The Dynamic Smart Array B140i is an 6Gb/s SATA controller providing support up to 10
SATA drives with RAID 0, RAID 1 and RAID 5 capabilities. The controller allows RAID
volumes across all 10 drives in a single RAID set. The Dynamic Smart Array
controllers share the same easy and consistent UI with standup Smart Array
controllers, thus making storage management and deployment easier for IT workers.
Ideal for:
The HP Dynamic Smart Array B140i controller comes as the default option on ProLiant
Gen9 servers unless controller is upgraded to H or P series cards.

39
Copyright 2014 Hewlett-Packard Development Company, L.P. The information contained herein is subject to change without notice. Authorised HP Channel
Partners Only
HP Dynamic Smart Array
B140i/B120i/B320i HP Dynamic Smart Array B140i HP Dynamic Smart Array B120i HP Dynamic Smart Array B320i

Form factor Embedded on all Gen9 servers Embedded on select Gen8 servers Embedded on select Gen8 servers

Chipset Intel Wellsburg Intel Patsburg LSI SAS

SAS/SATA 10 SATA ports (2 x4 / 2 x1) 6 SATA ports 6 SATA ports or 6 SAS/SATA with Lic.
connectivity
Storage protocol 6Gb/s SATA 6Gb/s SATA 6Gb/s SATA

Max drives Up to 10 SATA / future NGFF drives support Up to 6 SATA drives Up to 6 SATA drives

Software HP SSA, SMH, SIM, HP Service Pack for HP SSA, ACU, SMH, SIM, HP Service Pack for HP SSA, ACU, SMH, SIM, HP Service Pack for
management ProLiant Storage ProLiant Storage ProLiant Storage
RAID 0
RAID 1 & 10 RAID 0 RAID 0
Need UEFI enabled to have
RAID support (Drive
SATA SW RAID support
RAID 1 & 10 (Drive Mirroring) RAID 1 & 10 (Drive Mirroring)
Mirroring) RAID 5 (requires FBWC) RAID 5 (requires FBWC)
RAID 5

Write Cache No Write Cache Option Optional 512MB FBWC @ $199 Optional 512MB FBWC @ $199

Encryption Not supported Not supported Not supported


support
HP Smart Cache Not supported Not supported Not supported

UEFI support Supported Not supported Not supported

40
Copyright 2014 Hewlett-Packard Development Company, L.P. The information contained herein is subject to change without notice. Authorised HP Channel
Partners Only
HP Smart Array P440ar Controller
Product overview:
The HP Smart Array P440ar is a 12 Gb/s
controller that provides increased performance
and flexibility over the previous generation.
The controller offers 2 GB flash backed write
cache (FBWC) embedded to maximize data
protection in case of a power failure. The
P440ar controller is designed for HP ProLiant
DL360, DL380 and ML350 Gen9 servers for
direct attached storage without occupying a
PCIe slot. The Smart Array controller also
supports HP Secure Encryption.
Ideal for:
The HP P440ar is ideal for mid-range to
enterprise level direct attached SAS storage
performance for file server, application server,
messaging server, and database applications.
41
It Copyright
is also 2014ideal for environments
Hewlett-Packard Development Company, L.P. where
The information contained herein is subject to change without notice. Authorised HP Channel
Partners Only
HP Smart Array P440 Controller
Increased performance and data availability for ProLiant storage
Product overview:
The HP Smart Array P440 is a 12 Gb/s controller
that provides increased performance over the
previous generation. The controller supports
flash backed write cache (FBWC) to maximize
data retention in case of a power failure. The
P440 controller is designed for HP ProLiant Gen9
enterprise servers for direct attached storage
and supports HP Secure Encryption without the
need for PCIe slot.
Ideal for:
The HP P440 is ideal for mid-range to enterprise
level direct attached SAS storage performance
for file server, application server, messaging
server, and database applications. It is also ideal
for environments where encryption of sensitive
Copyright 2014 Hewlett-Packard Development Company, L.P. The information contained herein is subject to change without notice. Authorised HP Channel
42
data
Partnersis required.
Only
HP Smart Array P440/P430/P420
Comparison HP Smart Array P440 HP Smart Array P430 HP Smart Array P420

Form factor Flexible Smart Array or PCI-Express (PCIe) 3.0 PCI-Express (PCIe) 3.0 PCI-Express (PCIe) 3.0
DDR3-1600 MHz, 72-bit wide bus at 12.8
Memory bus DDR3-1866 MHz, 72-bit wide bus at 14.9 GB/s (2GB FBWC Model) DDR3-1600 MHz, 72-bit wide bus at 10.6
speed GB/s DDR3-1866 MHz, 72-bit wide bus at 14.9 GB/s
GB/s (4GB FBWC Model)
Memory options 2GB FBWC P440ar or 4GB FBWC P440 2GB or 4GB FBWC 2GB FBWC or 1GB FBWC
2 internal x4 Mini-SAS connectors with
optional HP 12Gb SAS Expander card support
SAS/SATA (P440ar)
1 internal x8 Mini-SAS double-wide connector 2 internal x4 Mini-SAS connectors
connectivity 1 internal x 8 Mini-SAS double-wide with
optional HP 12Gb SAS Expander card support
(P440)
Storage protocol 12Gb/s & 6Gb/s 12Gb/s & 6Gb/s 6Gb/s
Max drives is dependent on the server the Max drives is dependent on the server the
Up to 26 with HP 12 Gb SAS Expander card
controller attaches to. Current max drives is controller attaches to. Current max drives is
Max drives (P440ar)
27 based on the DL380e that this controller is 60 based on the SL4540 that this controller is
Up to 60 depending on server (P440)
compatible with. compatible with.
Software HP SSA, SMH, SIM, HP Service Pack for HP SSA, ACU, SMH, SIM, HP Service Pack for HP SSA, ACU, SMH, SIM, HP Service Pack for
management ProLiant Storage ProLiant Storage ProLiant Storage
RAID 6 (Advanced Data Guarding), RAID 60, RAID 6 (Advanced Data Guarding), RAID 60, RAID 6 (Advanced Data Guarding), RAID 60,
RAID 5 (Distributed Data Guarding), RAID 50, RAID 5 (Distributed Data Guarding), RAID 50, RAID 5 (Distributed Data Guarding), RAID 50,
RAID support RAID 1 & 10 (Drive Mirroring), RAID 1 ADM & RAID 1 & 10 (Drive Mirroring), RAID 1 ADM & RAID 1 & 10 (Drive Mirroring), RAID 1 ADM &
10 ADM (Advanced Data Mirroring) 10 ADM (Advanced Data Mirroring) 10 ADM (Advanced Data Mirroring)
Encryption Optional HP Secure Encryption Optional HP Secure Encryption Not supported
support
43
HP Smart Cache
Copyright 2014 Hewlett-Packard
Optional Development Company, L.P. The information contained herein is subject to change without notice.
Optional Authorised
Optional HP Channel
Partners Only
HP Smart Array P840 Controller

Product overview:
The HP Smart Array P840 is a 12 Gb/s
controller allowing customers to expand their
internal storage from a single drive cage to
the second drive cage effortlessly while
managing volumes and data from a single
controller. The controller supports flash
backed write cache (FBWC) to maximize data
retention in case of a power failure. The P840
controller is designed for HP ProLiant Gen9
rack mount and tower servers for direct
attached storage and supports HP Secure
Encryption. This controller offers HP
SmartCache as base feature.
Ideal for:
The HP P840 is ideal for mid-range to
enterprise level direct attached SAS storage
Copyright 2014 Hewlett-Packard Development Company, L.P. The information contained herein is subject to change without notice. Authorised HP Channel
44
performance for file server, application server,
Partners Only
HP Smart Array P840/P830
HP Smart Array P840 HP Smart Array P830

Form factor PCI-Express (PCIe) 3.0 PCI-Express (PCIe) 3.0

Memory bus DDR3-1866 MHz, 72-bit wide bus at 14.9 GB/s DDR3-1866 MHz, 72-bit wide bus at 14.9 GB/s
speed
Memory options 4GB FBWC 4GB FBWC

SAS/SATA 2 internal x8 double-wide connector 2 internal x8 double-wide connector


connectivity
Storage protocol 12Gb/s & 6Gb/s 12Gb/s & 6Gb/s
Max drives is dependent on the server the
Up to 16 without HP 12Gb SAS Expander card; controller attaches to. Current max drives is 16
Max drives up to 48 with 2 x HP 12Gb SAS Expander card based on the DL380p that this controller is
compatible with.
Software HP SSA, SMH, SIM, HP Service Pack for ProLiant HP SSA, ACU, SMH, SIM, HP Service Pack for
management Storage ProLiant Storage
RAID 6 (Advanced Data Guarding), RAID 60, RAID 6 (Advanced Data Guarding), RAID 60,
RAID 5 (Distributed Data Guarding), RAID 50, RAID 5 (Distributed Data Guarding), RAID 50,
RAID support RAID 1 & 10 (Drive Mirroring), RAID 1 ADM & 10 RAID 1 & 10 (Drive Mirroring), RAID 1 ADM & 10
ADM (Advanced Data Mirroring) ADM (Advanced Data Mirroring)
Encryption Optional HP Secure Encryption Optional HP Secure Encryption
support
HP Smart Cache Standard Standard

UEFI supported Supported Supported

Legacy BIOS Supported Supported


support
45
Copyright 2014 Hewlett-Packard Development Company, L.P. The information contained herein is subject to change without notice. Authorised HP Channel
Partners Only
HP Smart Array P441 Controller

Product overview:
The HP Smart Array P441 is a 12 Gb/s
controller providing increased
performance, external storage scalability,
data protection and security. The controller
supports flash backed write cache (FBWC)
to maximize data retention in case of a
power failure. The P441 controller is
designed for HP ProLiant Gen9 rack mount
and tower servers for external direct
attached storage and supports HP Secure
Encryption.
Ideal for:
The HP P441 is ideal for mid-range to
enterprise level external direct attached
SAS storage performance for file server,
Copyright 2014 Hewlett-Packard Development Company, L.P. The information contained herein is subject to change without notice. Authorised HP Channel
46
application
Partners Only server, messaging server, and
HP Smart Array Controllers
HP Smart Array P441
Low Profile card PCIe 3.0 x8
PCI Bus card

Memory bus DDR3-1866 MHz 72bit


speed
Memory 4GB FBWC
options
2 external x4 ports mini-SAS
SAS/SATA HD connectors with expander
Connectivity support

Max Drives Up to 200

Software SSA, SMH, SIM, HP Service


Management Pack for ProLiant Storage

RAID 6 (Advanced Data


Guarding), RAID 60, RAID 5
(Distributed Data Guarding),
RAID Support RAID 50, RAID 1 & 10 (Drive
Mirroring), RAID 1 ADM & 10
ADM (Advanced Data
Mirroring)

47
Copyright 2014 Hewlett-Packard Development Company, L.P. The information contained herein is subject to change without notice. Authorised HP Channel
Partners Only
Gen9 Storage options for DL360, DL380 and
ML350 P840/4GB
P440/4GB
P440ar/2G - 16 port 12 Gb/s
- 8 port 12 Gb/s SAS/SATA
H240ar B
- 8 port SAS/SATA controller
B140i - 8 port SAS/SATA
SAS/SATA controller - RAID 0, 1, 5, 6,
controller - RAID 0, 1, 5, 6, 60 and ADM
controller
- 10 port SATA - RAID 0, 1, 5, 6, 60 and ADM - 4GB 72bit
- No cache
controller using 60 and ADM - 4GB 72bit FBWC
Wellsburg - HBA or RAID
- 2GB FBWC FBWC - RAID or HBA
chipset Mode
- RAID or HBA - RAID or HBA Mode
- Basic RAID 0, 1 - RAID 0, 1 and 5
mode Mode - SmartCache
and 5 Optional
upgrades - Smart Storage Optional Optional
- No cache Battery included upgrades upgrades
- 12 Gb SAS
- AHCI mode Optional - 12 Gb SAS - 12 Gb SAS
Expander
- SA firmware upgrades Expander Expander
and drivers for - Expander card - SmartCache - Secure
Windows, Linux Encryption
- SmartCache - Secure
and VMware
Encryption
- Secure
ath
Upgrade p
Encryption

48
Copyright 2014 Hewlett-Packard Development Company, L.P. The information contained herein is subject to change without notice. Authorised HP Channel
Partners Only
Gen9 Storage options for entry Rack and Tower
servers
P840/4GB
- 16 port 12 Gb/s
P440/4GB SAS/SATA controller
- 8 port 12 Gb/s - RAID 0, 1, 5, 6, 60
SAS/SATA controller and ADM
H240 - RAID 0, 1, 5, 6, 60 - 4GB 72bit FBWC
- 8 port SAS/SATA and ADM - RAID or HBA Mode
B140i controller - 4GB 72bit FBWC - SmartCache
- 10 port SATA - No cache - RAID or HBA Mode Optional upgrades
controller using - HBA or RAID Mode Optional upgrades - Expander card
Wellsburg chipset - RAID 0, 1 and 5 - Expander card - Secure Encryption
- Basic RAID 0, 1 and Optional upgrades - SmartCache
5 - Secure Encryption
- Expander card
- No cache
- Secure Encryption
- AHCI mode (RAID mode only)
- SA firmware and
d e pat h
Upgra
drivers for Windows,
Linux and VMware

49
Copyright 2014 Hewlett-Packard Development Company, L.P. The information contained herein is subject to change without notice. Authorised HP Channel
Partners Only
Available

HP 12Gb/s SAS Expander Card


Description Is What is the Does What it Means Customer Associated Quants/Claims
new, unique does function value statement,
differentiator benefit
Full height PCIe 12 Gb/s Expander Allows customer Provides internal storage Allows internal storage
card supports 12 Card to address data expansion allowing expansion without having to
Gb/s SAS growth within the customers to add an external storage
connectivity and server consolidate compute which equates to about 50%
features 9 and storage space reduction in a data
internal ports center and less power
with a maximum consumption
of 26 physical
links

50
Copyright 2014 Hewlett-Packard Development Company, L.P. The information contained herein is subject to change without notice. Authorised HP Channel
Partners Only
HP 12G SAS Expander Card
Increase storage capacity within server
Product overview:
The HP 12G SAS Expander Card provides servers with
internal storage scalability while protecting data. The
HP 12G SAS Expander card is supported in DL380,
ML350, and DL180 Gen9 servers using the HP Smart
Array or HP Smart HBA controllers.
Full storage configuration and management of
volumes from single Smart Array or Smart HBA
controller.
Ideal for:
The HP 12G SAS expander card is ideal for mid-range
to enterprise level customers looking to add internal
direct attached SAS storage for file, messaging, and
database applications.

51
Copyright 2014 Hewlett-Packard Development Company, L.P. The information contained herein is subject to change without notice. Authorised HP Channel
* Please check QS for supported controllers
Partners Only
12Gb SAS Expander
8 SFF BAY
3 8 SFF BAY
PORT 2 3 8 SFF BAY 1
PORT 1 PORT 2 8 SFF BAY 1

Option
PORT 1 8 SFF BAY 1
PORT 2 8 SFF BAY
1
PORT 1

Rear Drives Up to 24 drives across


2 SFF/3 LFF storage backplanes

Internal
Controller

52
Copyright 2014 Hewlett-Packard Development Company, L.P. The information contained herein is subject to change without notice. Authorised HP Channel
Partners Only
Stand alone SAS expander - HP 12Gb SAS
Expander card Por Cable label to SAS SAS
Drive numbers
t board board

9 1 In-Port 1 PORT 1 N/A


8 7 2 In-Port 2 PORT 2 N/A
8 SFF BAY 1 / PORT
3 PORT 1 1-4
1
6 5 8 SFF BAY 1 / PORT
4 PORT 2 5-8
2
8 SFF BAY 2 / PORT
4 3 5 PORT 1 9-12
1
8 SFF BAY 2 / PORT
6 PORT 2 13-16
2
2 1 7
8 SFF BAY 3 / PORT
PORT 1 17-20
1
8 SFF BAY 3 / PORT
8 PORT 2 21-24
2
9 2 SFF/3 LFF PORT 1 PORT 1

53
Copyright 2014 Hewlett-Packard Development Company, L.P. The information contained herein is subject to change without notice. Authorised HP Channel
Partners Only
Available

HP 12Gb/s Smart HBA


Description Is What is the Does What it Means Customer Associated Quants/Claims
new, unique does function value statement,
differentiator benefit
Controller that 12 Gb/s SAS, Accelerate Balance escalating Provides basic RAID
provides SAS Flexible Smart access to data on storage needs with Rapid rebuild of drives
connection to SAS HBA form the direct essentially flat budgets Power efficiency reduces
direct attach factor, run in attached storage, and address need for TCO especially when fewer
storage and to either HBA mode tape software-defined storage drives are used in the
shared storage or simple RAID to manage their IT infrastructure (e.g. Blade
mode storage pool servers and a SAN as the
backend storage)
Non-disruptive flashing of
SAS drives (available in snap
2), there is no need to reboot
the server after firmware
updates thereby minimizing
downtime associated with
maintenance

54
Copyright 2014 Hewlett-Packard Development Company, L.P. The information contained herein is subject to change without notice. Authorised HP Channel
Partners Only
HP Smart HBA
6Gb/12Gb Smart HBA
Type Ports Cache Connec
tor
H240ar Smart HBA SAS 8 No 2 x4
H240 Smart HBA SAS 8 No 2 x4

H240

H240ar

55
Copyright 2014 Hewlett-Packard Development Company, L.P. The information contained herein is subject to change without notice. Authorised HP Channel
Partners Only
HP Smart HBA H240ar Controller
Product overview:
The HP Smart HBA H240ar is a 12 Gb/s controller
that provides increased performance over the
previous generation. The H240 controller is
designed for HP ProLiant DL360, DL380 and ML350
Gen9 servers allowing expansion of storage density
within the server. The controller also offer basic
RAID mode allowing RAID 0, 1 and 5 configuration.
H240ar provides new levels of reliability, storage
performance and supports HP Secure Encryption for
HP Gen9 blade servers through its support of the
latest Smart Array technology and advanced
firmware optimizations.
Ideal for:
The HP H240 is ideal for mid-range to enterprise
level direct attached SAS storage performance for
file server, application server, messaging server,
Copyright 2014 Hewlett-Packard Development Company, L.P. The information contained herein is subject to change without notice. Authorised HP Channel
56
and database applications.
Partners Only
HP Smart HBA H240 Controller
Product overview:
The HP Smart HBA H240 is a 12 Gb/s controller that
provides increased performance over the previous
generation. The H240 controller is designed for HP
ProLiant Gen9 servers allowing expansion of storage
density within the server. The controller also offer
basic RAID mode allowing RAID 0, 1 and 5
configuration. H240 provides new levels of
reliability, storage performance and supports HP
Secure Encryption for HP Gen9 blade servers
through its support of the latest Smart Array
technology and advanced firmware optimizations.

Ideal for:
The HP H240 is ideal for mid-range to enterprise
level direct attached SAS storage performance for
57
file server,
Copyright application
2014 Hewlett-Packard server,
Development messaging
Company, L.P. server,
The information contained herein is subject to change without notice. Authorised HP Channel
Partners Only
HP Smart Host Bus Adapters
Reliable high performance SAS connectivity for HP ProLiant servers

Simplicity Agility Efficiency


HP Smart Storage Optimized for Improved Power
Administrator (SSA) performance Efficiency
provides a Designed for ProLiant
comprehensive utility server and storage
to manage, configure architecture
and diagnose the Scale internal server
storage attached to the storage with new
controller 12Gb/s SAS Expander
Cost effective solution Operate in either RAID
for attaching SAS or or HBA mode
SATA storage to ProLiant HP Flexible Smart
SAS HBA designed to
meet unique
requirements
Support tape, DAS, and
shared storage

58
Copyright 2014 Hewlett-Packard Development Company, L.P. The information contained herein is subject to change without notice. Authorised HP Channel
Partners Only
HP Smart HBA H240/H220
HP Smart HBA H240 HP H220 HBA

Flexible Smart SAS HBA H240ar or PCI-


Form factor Express (PCIe) 3.0 H240
PCI-Express (PCIe) 3.0

2 internal x4 Mini-SAS connectors H240ar


SAS/SATA connectivity 2 internal x4 Mini-SAS connectors H240
2 internal x4 Mini-SAS connectors

Storage protocol 12Gb/s & 6Gb/s SAS/SATA 6Gb/s


Up to 26 with HP 12 Gb SAS Expander
Max drives card H240ar Up to 60 drives depending on server
Up to 60 depending on server H240
HP SSA, SMH, SIM, HP Service Pack for HP SSA, SMH, SIM, HP Service Pack for
Software management ProLiant Storage, Storage Management ProLiant Storage, Storage Management
Utility Utility
RAID 5 (Distributed Data Guarding),
RAID support RAID 1 & 10 (Drive Mirroring) Not supported
supported in a simple RAID mode
Supported (default mode)
HBA mode Mixed mode (not supported)
Supported

Encryption support TBD Not supported

HP Smart Cache Not supported Not supported

UEFI support Supported Not supported

Legacy BIOS support Supported Not supported

Tape drive support Supported on select servers Supported on select servers

59
Copyright 2014 Hewlett-Packard Development Company, L.P. The information contained herein is subject to change without notice. Authorised HP Channel
Partners Only
HP Smart HBA H241 Controller
Product overview:
The HP Smart HBA H241 is a 12 Gb/s controller that
provides increased performance over the previous
generation supporting direct attached storage,
shared storage and tape drives. The H241
controller is designed for HP ProLiant Gen9 servers
allowing external storage expansion and direct
connectivity. The controller also offer basic RAID
mode allowing RAID 0, 1 and 5 configuration.
Ideal for:
The HP H241 is ideal for mid-range to enterprise
level direct attached SAS storage performance for
file server, application server, messaging server,
and database applications. It is also useful for
environments that do not require advanced RAID
capabilities.
60
Copyright 2014 Hewlett-Packard Development Company, L.P. The information contained herein is subject to change without notice. Authorised HP Channel
Partners Only
HP Smart Host Bus Adapter
HP Smart HBA
H241
Low Profile card PCIe 3.0
PCI Bus x8 card
2 external x4 ports mini-
SAS/SATA SAS HD connectors with
Connectivity expander support

Max Drives Up to 200 with D3700


HP SSA, SMH, SIM, HP
Software Service Pack for ProLiant
Management Storage
RAID 5 (Distributed Data
Guarding),
RAID RAID 1 & 10 (Drive
Support Mirroring)
supported in a simple RAID
mode
Supported (default mode)
HBA Mode Mixed mode (not
supported)

61
Copyright 2014 Hewlett-Packard Development Company, L.P. The information contained herein is subject to change without notice. Authorised HP Channel
Partners Only
Smart Array product naming framework
HP Smart Array X###xx Controller
Family Media
B-Series i= Integrated
Embedded low cost entry controller m = Mezzanine card
Max 10 SATA drives support br = Blade ROC
P-Series ar = Adaptive ROC for 300 series
AROC, BROC servers
Standup
Mezz
Supports > 8 drives Ports
0 = Internal ports
1 = external ports
Series 2 = internal and
200 = Base or entry series Generation external ports
400 = Scale or mainstream 0 = 3G SAS controllers
4 = BL460 specific
series 1 = 6G SAS controllers
6 = BL660 specific
700 = Premium or 2 = 6G 2nd generation controllers (Gen8)
performance series for 3 = 12G ready controllers w/encryption
BladeSystem for Gen8
800 = Premium or 4 = 12G controllers for Gen9
62 performance
Copyright series
2014 Hewlett-Packard for Company, L.P.
Development The information contained herein is subject to change without notice. Authorised HP Channel
Partners ML/DL/SL
Only
Smart HBA product naming framework
HP X###xx Smart Host Bus Adapter {RAID
mode}
Family Media
H-Series i= Integrated
br = Blade HBA
Host Bus Adapter ar = Adaptive HBA for 300 series
Supports >8 servers
drives

Series Ports
200 series
Generation

0 = Internal ports
1 = external ports
2 = 6G 2nd generation controllers
(Gen8)
2 = internal and external
4 = 12G controllers for Gen9 ports
4 = BL460 specific
6 = BL660 specific
63
Copyright 2014 Hewlett-Packard Development Company, L.P. The information contained herein is subject to change without notice. Authorised HP Channel
Partners Only
Smart Array and HBA transition
Embedded
Gen8
Embedded
/ Stand
Gen9
Embedded up Gen8 Smart
Array
Gen9 Smart
Array
B120i B140i
P830/4GB P840ar/2GB
(Patsburg) (Wellsburg)
P220i/230i P24xbr P420/1GB
P440/4GB
H240ar (HBA P420/430
H220i
mode) w/2GB
H240 (RAID
B320i w/ZM
mode) P421/1GB
H240ar (RAID P441/4GB
P420i w/ZM P421/431
mode) w/2GB
B320i
w/512MB P440 P822/2GB P841/4GB
P420i
w/512,1,2G P721m/P731m P741m/4GB

Gen8 HBAs Gen9 HBAs SAS Expander

H220 H240

H221 H241

64
Copyright 2014 Hewlett-Packard Development Company, L.P. The information contained herein is subject to change without notice. Authorised HP Channel
Partners Only
Available

HP 12Gb/s SAS HDD/SSD


Description Is What is the Does What it Means Customer Associated Quants/Claims
new, unique does function value statement,
differentiator benefit
SAS Hard Disk 12 Gb/s SAS Value Maximize 2X more performance than 6
Drive; HDD Endurance SSD performance, data Gb SAS
Solid State Drive 12 Gb/s SSD ideal for file, availability and Rigorous ProLiant
messaging, and storage capacity for qualification 2.4M test
DB applications your Gen9 servers hours
for maximum Maximize throughput HP SmartSSD Wear Gauge
performance in a logical volume compatibility with
Mainstream management tools for
Endurance and monitoring SSD life
High Endurance HP drive carrier provides self-
SSD - OLTP, BI, describing icons for activity
Big Data reporting, do not remove
Analytics, VDI, button to prevent data loss
etc. for
maximum
performance
HDD ideal for
file, messaging,
DB application,
OLTP, BI, Big
Data Analytics,
VDI etc. at a
Copyright 2014 Hewlett-Packard Development Company, L.P. The information contained herein is subject to change without notice. Authorised HP Channel
65
lower price point
Partners Only
HP SmartDrives (HDD)
Products segmented by enterprise and midline to meet the requirements
of the right workloads at the right economics
Simplicity Agility Reliability
Self-describing Consistency and Focus on Time to
icons for activity predictability of quality(TTQ)
reporting performance Robust test
Carrier guards Optimized for process over
against counterfeit ProLiant 1.25M hours
drives infrastructure Full data path error
Do not remove Complete portfolio detection
button prevents across SAS and Surprise power loss
data loss SATA; 12Gb SAS protection
Universal form supporting new Carrier collects
factors across Gen9 ProLiant failure data
ProLiant family Servers
Assurance of
supply

66
Copyright 2014 Hewlett-Packard Development Company, L.P. The information contained herein is subject to change without notice. Authorised HP Channel
Partners Only
HP SmartDrives Solid State Drives (SSDs)
The right SSD for every application, providing the best technologies to
deliver exceptional performance, reliability and efficiency
Agility Efficiency Reliability
12Gb SAS SSDs 50% more Rigorous ProLiant
Excellent compute per Qualification - 2.4 Million
Performance and watt with Test Hours
Latency server, SSDs HP Firmware ensures
Complete SSD and system compatibility, consistency
portfolio across power can be Full data path error detection
SAS and SATA planned with Power loss protection
First to market Power Advisor HP SmartSSD Wear Gauge
with the best tool compatibility with
technology Self-describing management tools for
LEDs eliminate monitoring SSD life
drive activity Full HP Service/Support,
confusion including field F/W upgrades

67
Copyright 2014 Hewlett-Packard Development Company, L.P. The information contained herein is subject to change without notice. Authorised HP Channel
Partners Only
HP Enterprise Solid State Categories
HP PCIe Workload HP Enterprise SAS/SATA SSDs Client
Accelerators Based SSDs
Performa
Mainstream Value Boot Value
Performa Mainstre nce
Value
nce am Drive form Drive form Drive form
Drive form factor factor factor Drive form
factor factor
PCIe /
PCIe / PCIe / 12/6 Gb SAS or 12/6 Gb SAS or
Mezz / 12/6 Gb SAS 6 Gb SATA 6 Gb SATA
SCSIe SCSIe 6/3 Gb SATA 6/3 Gb SATA
SCSIe
Up to 25 Up to 10 Up to 1 Up to 25 Up to 10 Up to 1 Up to 1 Less than 1
DWPD DWPD DWPD DWPD DWPD DWPD DWPD DWPD
Unrestricted High read/low High read/ High read/low
Applications that require lowest Mixed read/write
read/write write Dynamic write
latency response times applications
applications Applications Throttled Write applications

Full Datapath error detection


Enterprise = SmartSSD Wear Gauge support
Typically with surprise power loss protection
The information contained herein is subject to change without notice. Authorised HP Channel
68
Copyright 2014 Hewlett-Packard Development Company, L.P.
Partners Only
Introducing HPs 12Gb SAS Value
Endurance SSDs Best IOPS/$ for SAS SSDs
Prices starting at $3899 for 800GB
Industry-Leading Performance
Up to Read 96,000 IOPS (random 4KiB,Q16)
Up to Write 28,000 IOPS (random 4KiB,Q16)
Sequential Reads/Writes
1,000 MiB/s (Reads), 390 MiB/s (Writes)
More Capacity
Capacities up to 1.6TB
Workload Optimized
Read-intensive workloads
Value Endurance Value Endurance 1 Drive Writes Per
Capacities: Day (DWPD)
800GB, 1.6TB
Enterprise Reliability
69
Copyright 2014 Hewlett-Packard Development Company, L.P. The information contained herein is subject to change without notice. Authorised HP Channel
Partners Only
Available

HP PCIe Workload Accelerators


Description Is What is the Does What it Means Customer value Associated
new, unique does function statement, benefit Quants/Claims
differentiator
PCIe card- Uses solid state Provides low The associated application 2X better latency for
based, storage system latency (on performance improvements applications such as
advanced technology PCIe bus with will have a positive impact on OLTP
storage devices directly on the PCI processor and business results and the 40% more compute
bus memory) ability to accelerate IO-bound per watt of power with
Assures high read workloads like databases, server & Accelerators
and write data virtualization and data Host entire database
rates analytics, resulting in on 1 HP Accelerator
Accelerates significant cost and time 4x more transactions
application savings. per server
performance Performance up to
Ideal for enterprise workloads 160,000 Read IOPS
requiring real-time data
access with high transaction
rates and low latency.

70
Copyright 2014 Hewlett-Packard Development Company, L.P. The information contained herein is subject to change without notice. Authorised HP Channel
Partners Only
HP PCIe Workload Accelerators
Smarter, faster applications made possible by best latency, performance
and reliability, while reducing total cost of ownership
Simplicity Agility Reliability
2x better latency 4X more Rigorous ProLiant
for applications transactions per Qualification
such as OLTP server1 Full data path error
Host entire 40% more detection
database on 1 HP compute with Surprise power
Accelerator server and loss protection
Accelerators2 Environmental
Performance up to ruggedness vs.
160,000 Read IOPS HDD
Most complete HP FW/Drivers
portfolio; first to ensure
market with the consistency,
best technology compatibility
4x performanceacceleration based on Fusion-IOtesting of the HP ProLiant DL580 Gen8 Server with HP Light Endurance (LE) or Value
1

Endurance (VE) PCIe Workload Accelerators running Microsoft SQL Server 2014.Source: MS SQL Server 2014 Solution Brief: 4AA5-
3287ENW
2
40%+ performance improvement with a DL380 Gen9 configuration using Gen3 PCIe Accelerator cards over a DL380p Gen8
configuration using Gen2 PCIe Accelerator cards in a commonly used workload running in virtualized environment using ESXi 5.5
Copyright 2014 Hewlett-Packard Development Company, L.P. The information contained herein is subject to change without notice. Authorised HP Channel
71

Partners Only
Introducing HPs Value Endurance PCIe
Workload Accelerators Best PCIe IOPS/$
Prices starting at $8899 for 1.3TB
Industry-Leading Performance
Up to Read 68,000 IOPS (random 4KiB,Q16)
Up to Write 69,000 IOPS (random 4KiB,Q16)
Excellent Latency
Access Latency (4KiB,Q1)
110 microseconds (Reads), 30
microseconds (Writes)
2X More Capacity
Capacities up to 6.4TB
Workload Optimized
Value Endurance Cloud and Scale Out Applications
Capacities: Value Endurance 0.5 Drive Writes Per
1.3TB HH/HL, 1.6TB Day (DWPD)
72
HH/HL,
Copyright 2014 Hewlett-Packard Development Company, L.P. The information contained herein is subject to change without notice. Authorised HP Channel
Partners Only
Available

HP SmartCache with SSD


Description Is What is Does What it Means Customer Associated Quants/Claims
the new, does function value statement,
unique benefit
differentiator
Smart Array Write-Back Takes SSDs in a Accelerates performance HP SmartCache provides up
Controller-based feature added direct attached of applications where to 4x read and write
caching solution to the Gen9 storage data is frequently workload acceleration
supported Smart environment and referenced
Array Controllers utilizes them as
caching devices by
copying the most
frequently
accessed data
often called hot
dataonto
lower latency SSDs
to accelerate
application
workloads.

73
Copyright 2014 Hewlett-Packard Development Company, L.P. The information contained herein is subject to change without notice. Authorised HP Channel
Partners Only
HP SmartCache for HP Smart Array
HP SmartCache solution highlighted
controllers
Target Customers Key Selling Points
HP ProLiant Gen9 server customers who have: Accelerate workloads with minimal investment into
Read intensive workloads with repetitive data SSDs
requests Seamless integration into datacenter
Write intensive workloads that require Increased utilization and efficiency
acceleration Simplified management utilizing HP SSA
HP SmartCache

Enterprise-
Leading storage Flexible networking class
management

74
Copyright 2014 Hewlett-Packard Development Company, L.P. The information contained herein is subject to change without notice. Authorised HP Channel
Partners Only
HP SmartCache - Summary
Up to 4x Better Workload Performance

Solution, Product, HP Sales/Channel


Customer Service Sales
Pain Points Description Whats in it for me?
Storage is a bottleneck Caching solution that caches Reason to Talk to
Constrained storage hot data onto lower latency Customer
budget SSDs Show them how to get
better workload
Ideal Key Selling Points performance
Read and write intensive Accelerate workloads with
workloads minimal investment into Help mitigate customer
Read acceleration for SSDs, seamless integration concerns
repetitive data requests into datacenter, centralized Seamless integration into
on bulk storage attached management existing environment
to Smart Array Minimal investment into
SSD
Competitive
advantage Retire Sales Quota with
Optimized for HP ProLiant additional licensing and SSD
75 sales
Copyright 2014 Hewlett-Packard Development Company, L.P. The information contained herein is subject to change without notice. Authorised HP Channel
Partners Only
Available

HP SSD Smart Path


Description Is What is Does What it Means Customer Associated Quants/Claims
the new, does function value statement,
unique benefit
differentiator
HP Smart Storage Gen8 to Gen9; Allows I/O requests Offers significant HP SSD Smart Path is capable
device driver that Supported on HP that meet certain performance gains for of delivering significant
improves the Smart HBA when requirements to storage environments performance gains (2X to 3.8X
performance of running in RAID bypass the normal where data is read improvement) when used in
Smart Array mode I/O path involving repeatedly from SSD environments where data is
Controllers in firmware layers, drives such as high being repeatedly read from SSD
SSD-based and instead use an frequency trading and drives.
ProLiant servers. accelerated I/O online transaction
operation. This processing.
process
accelerates reads
for all RAID levels
and writes for RAID
0.

76
Copyright 2014 Hewlett-Packard Development Company, L.P. The information contained herein is subject to change without notice. Authorised HP Channel
Partners Only
HP SSD Smart Path
Application( High performance option for SSD traffic
s)
OS Smart Array driver chooses optimum path to
Smart Array SSD
Driver
Reads for all RAID levels

SA SA RAID 0 writes
FW Controller Smart Array controller cache disabled

Smart Array firmware handles error


conditions
Physical SSD(s) SSD SSD
SSD
1
1
SSD
2
2 Configurable through HP Smart Storage
Logical Disk Administrator
Media surface scans by Smart Array
77
Authorised HP Channel
firmware
Copyright 2014 Hewlett-Packard Development Company, L.P. The information contained herein is subject to change without notice.
Partners Only
Available

HP StoreVirtual VSA
Description Is What is the new, Does What it Means Customer Associated
unique differentiator does function value statement, Quants/Claims
benefit
HP StoreVirtual Add storage capacity Transforms The ability to use Eliminate the need for
VSA is a virtual while increasing admin servers internal storage within physical arrays and
storage appliance productivity internal or customers reduce datacenter
optimized for Every HP ProLiant Gen9 direct environment footprint by 50%.
VMware vSphere server includes a FREE attached greatly increases Gain back 60% savings
and Microsoft 1TB license of HP storage into a storage utilization in energy costs by
Hyper-V StoreVirtual VSA now fully-featured eliminates the taking advantage of a
environments. It available through shared storage costs and converged solution.
creates a virtual Intelligent array without complexity 50% less space and
array within the Provisioning the cost and associated with gain back 60% savings
application Note: The customer can complexity dedicated external in energy costs with
server and scales purchase a License to associated storage HP StoreVirtual VSA
as storage needs Use (LTU) for a 4TB, with dedicated Deploy resilient shared
evolve. 10TB, or 50TB license storage The unique scale out storage at up to 80%
(each includes 3 years architecture offers the less cost than with
of support). The ability to add storage traditional storage
customer does not have capacity on-the-fly arrays.
to install any new without compromising
software they just performance.
input the license key
which enables the
additional capacity and
Copyright 2014 Hewlett-Packard Development Company, L.P. The information contained herein is subject to change without notice. Authorised HP Channel
78
adds support.
Partners Only
Available

HP Smart Storage Battery


Description Is What is Does What it Means Customer Associated Quants/Claims
the new, does function value statement,
unique benefit
differentiator
Single Lithium 96W central Backup power that A single battery can Simplifies cabling
ION battery battery replaces the support up to 16 devices Can support larger cache
connected to the backup individual in a ML/DL server and 3 capacity
system board system for SuperCaps used devices in a BL server Supports multiple devices
that provides the ML/DL with each Gen8 with one battery
backup power to servers; controller
all the Smart 12W central
Array Controllers battery
backup
system for
the BL
server

Support
larger cache
capacity

79
Copyright 2014 Hewlett-Packard Development Company, L.P. The information contained herein is subject to change without notice. Authorised HP Channel
Partners Only
HP Smart Storage Battery
Confidently protect your data with new HP Smart Storage Battery
Backup protection for your
data
Simple design to provide backup power for
multiple Smart Array controllers
Easy upgrade process for additional Smart
Array controllers without need for cable
routing
Supports much larger cache capacities
Long life (7 years) Lithium ION batteries
for Gen9 and future products that will be
available
Eliminates thermal and connection issues

80
Copyright 2014 Hewlett-Packard Development Company, L.P. The information contained herein is subject to change without notice. Authorised HP Channel
Partners Only
HP Smart Storage battery
Shared backup power
Moved from Supercap* (per
controller for backup power)
to shared battery across all
Smart Array controllers in a
system
Standup P-series cards require
cable from riser board to card
for backup power
Cable less connection to share
backup power source, HP
Smart Storage Battery
*Supercap = Temporary energy
Battery monitored by iLO storage.
The first way that capacitors are
96W for ML/DL, 12W for BL
81
Copyright 2014 Hewlett-Packard Development Company, L.P. used
The information contained herein is subject is for
to change temporary
without energy
notice. Authorised HP Channel
Partners Only storage.
Networking

Copyright 2014 Hewlett-Packard Development Company, L.P. The information contained herein is subject to change without notice.
Available

20Gb FlexFabric adapters on BL servers


Description Is What is the Does What it does Means Associated
new, unique function Customer value Quants/Claims
differentiator statement,
benefit Substantiation in Notes
Pages
New HP FlexFabric Double capacity Provide 10 GbE when As part of the Reduce hardware
20GbE 2-port 650 and increase overall connected to HP FlexFabric 10/20 components up to
Series Adapters server performance Virtual Connect Flex- Gb blade adapter 50%
converge data at less than half 10/10D Module and HP portfolio, HP Reduce I/O bottlenecks
center traffic and the cost. 6125 XLG Ethernet FlexFabric 20Gb with 2x bandwidth
offload server Multi-speed at Switch or 20 GbE 2-port 650 Series Deliver 2x
networking tasks to either 10GbE or connection with HP Adapters: improvement in
improve IT service 20GbE Virtual Connect Lower IOPs and faster live
delivery, reduce First adapter to FlexFabric 20/40 F8 operational migration time
costs and deliver converge FCoE or Module and acquisition
greater data center RoCE with LAN When connect to a costs
efficiency traffic on a single Virtual Connect Improve
Ethernet wire module, each port of network
the adapter becomes virtualization
four individual with VXLAN
components (called /NVGRE Tunnel
FlexNICs and Offload
FlexHBAs) that share Reduce latency
10/20Gb of bandwidth. with RoCE
Each FlexNIC or
83
Copyright 2014 Hewlett-Packard Development Company, L.P.
FlexHBA offers full
The information contained herein is subject to change without notice. Authorised HP Channel
Partners Only
HP FlexFabric 20Gb 2-port 650 Adapter:
Overview
New HP FlexFabric adapters for HP ProLiant Gen9 server blades provide full-
featured, high performance, converged 20Gb Ethernet that accelerates IT services
and increases data center efficiency across a broad range of I/O intensive
enterprise, cloud and Telco workloads.
Key Features:
First adapter to converge FCoE or RoCE
with LAN traffic on a single Ethernet
wire
Increases performance with full line rate
20GbE
per port
HP FlexFabric HP FlexFabric
Improves network virtualization with 650FLB 650M
VXLAN /NVGRE Tunnel Offload
84 Reduces latency with RDMA over
Copyright 2014 Hewlett-Packard Development Company, L.P. The information contained herein is subject to change without notice. Authorised HP Channel
Converged
Partners Only Ethernet (RoCE)
Increasing Data Center Agility with
20Gbtechnology
Flex-20 Innovation
enables network convergence

FlexNIC .5Gb Service


1A Console
FlexHB 8Gb Storage
A 1B Network
20Gb FlexNIC 10Gb VM
1C Network
FlexNIC
1.5Gb VMotion
1D

Performance Efficiency Simplicity


Increase connection Converge LAN and Centralized management
bandwidth flexibility SAN Non-disruptive bandwidth
Maximize capacity Increase VMs per link adjustments
utilization Reduce TCO
85
Copyright 2014 Hewlett-Packard Development Company, L.P. The information contained herein is subject to change without notice. Authorised HP Channel
Partners Only
Available

1Gb and 10Gb Ethernet on Rack &


Tower
Description servers
Is What is the
new, unique
Does What it
does function
Means Customer
value statement,
Associated
Quants/Claims
differentiator benefit
1Gb 4 ports: Gen8 to Gen9 Provides 1 Gb Choice of 2 ports or 4 NA
331FLR, 366FLR, connectivity to a ports 1 Gb cards
331T computer Choice of vendors
1Gb 2 ports: network for the (Emulex, QLogic, Intel,
332T, 361T server Broadcom, Solarflare)
FlexibleLOM Choice of standup or
provides choice FlexibleLOM for select
without using a servers
PCIe slot
10Gb 2 ports Gen8 to Gen9 Provides 10 Gb Small packet 2 port 10Gb will
FlexFabric: New are 556FLR- connectivity to a performance provide 5x
556FLR-SFP+, SFP+ and CN1200E computer improvement with the bandwidth over the 4
534FLR-SFP+, network for the new 556FLR-SFP+ and port 1Gb
533FLR-T, CN1200E server CN1200E Tunnel offload
10Gb 2 ports FlexibleLOM Features like RoCE & increases IO
Ethernet: provides choice VXLAN on the new throughput and CPU
571FLR-SFP+, without using a network controllers of effectiveness up to
561FLR-T, 561T, PCIe slot 556FLR-SFP+ and 129% and 46%
570SFP+ (private), 556FLR-SFP+ and CN1200E respectively
530SFP+, 530T, CN1200E 556FLR-SFP+ and 4x improvement in
561T, 552SFP, provides features CN1200E bring cost small packet
86571FLR-SPF+ like small packet
Copyright 2014 Hewlett-Packard Development Company, L.P. The information contained herein is subject effective, more
to change without feature
notice. performance
Authorised HP Channel
(private)
Partners Only processing, rich with the 2x improvement in
What are Overlay Networks (VXLAN)?
Scale networks with improved security
More networks
Greater mobility across sub-networks
Improved security

Traditional Networks Overlay Networks


L2 Domains L2 Domains L2 Domains

10.10.0.1 10.10.1.1 10.10.0.1 10.10.1.1 10.10.0.2


10.10.2.1 10.10.1.2
VXLAN
VXLAN

L3

4,096 VLANs 16,000,000 VLANs


87
Copyright 2014 Hewlett-Packard Development Company, L.P. The information contained herein is subject to change without notice. Authorised HP Channel
Partners Only
Available

Tunnel offload
Description Is What is the Does What it Means Customer Associated
new, unique does function value statement, Quants/Claims
differentiator benefit
Tunnel Offload on a HP Tunnel Offload the Minimize the impact of Increased throughput
10/20GbE adapter Offloading encapsulation, overlay networking on and CPU effectiveness
improves increases I/O decapsulation, host performance with up to 129 percent
performance and throughput, and checksum of Tunnel Offload support and 46 percent
scale of network reduces CPU VXLAN/NVGRE for VXLAN and NVGRE. respectively using
virtualization. utilization, and packet, therefore By offloading packet Tunnel Offload
lowers power reducing CPU processing to adapters, 122 percent
consumption. consumption. customers can more improvement in power
Tunnel Offload Hypervisor and efficiently use overlay efficiency compared to
supports VMwares Host CPU no networking to increase using BE3 adapters
VXLAN and longer process VM migration flexibility Increased scale of
Microsofts NVGRE VXLAN/NVGRE and network scale with VLANs beyond the
solutions. tags. Enable low- minimal impact to traditional limit of
latency VM performance. 4,096
operations.

88
Copyright 2014 Hewlett-Packard Development Company, L.P. The information contained herein is subject to change without notice. Authorised HP Channel
Partners Only
Boost Server Efficiency for Overlay
Networking
Offload host VXLAN/NVGRE processing to HP FlexFabric 556/650
adapters
Tunnel Offload
implementation Increase I/O
HP 556/650 throughput
AdapterVXLAN
VXLAN
Processing
Processing

Hypervisor Reduce
CPU utilization
CPU VXLAN
Processing
Processing

Reduce powerReduce power


Adapter offloads CPU
Hypervisor no longer processes consumption
VXLAN tags
Enables low-latency VM
operations Increase VM security and network scale with minimal impact
89 on performance
Copyright 2014 Hewlett-Packard Development Company, L.P. The information contained herein is subject to change without notice. Authorised HP Channel
Partners Only
Available

RDMA over Converged Ethernet (RoCE)


Description Is What is the Does What it does Means Customer Associated
new, unique function value statement, Quants/Claims
differentiator benefit
An accelerated Increase data RDMA data transfer is Dramatically Faster live
I/O delivery center performed by the DMA increase data migration time
mechanism that efficiency, engine on the adapter's transfer efficiency Low latency
allows data to be provide low network processor. The with very low
transferred latency and CPU is not used for the data latencies for
directly from the deliver movement, freeing it to applications such as
user memory of accelerated perform other tasks such Microsoft Hyper-V
the source server performance has hosting more virtual Live Migration,
to the user over Ethernet. workloads (increased VM Microsoft SQL and
memory of the density). Microsoft Storage
destination server RDMA also bypasses the Spaces with SMB
bypassing the host TCP/IP stack, in favor of Direct 3.0.
operating system upper layer InfiniBand RoCE reduces CPU
(OS) kernel. protocols implemented in utilization and helps
the adapter's network maximize host VM
processor. The bypass of density and server
the TCP/IP stack and the efficiency.
removal of a data copy step Using SMB with
reduce overall latency to RoCE, Hyper-V Live
deliver accelerated Migration is much
performance. faster than TCP/IP.
90
Copyright 2014 Hewlett-Packard Development Company, L.P. The information contained herein is subject to change without notice. Authorised HP Channel
Partners Only
What is RDMA?
Remote Dynamic Memory Access (RDMA)
A method of moving buffers between two applications across a network efficiently
Communication between apps/servers bypasses most/all of the kernel services
Brought to standards body and first implemented in HPC segment
Developed first in HP Labs over 20 years ago!
HP contributed to the Virtual Interface Architecture (VIA) standard
Eventually rolled into the InfiniBand standard set

Why is this better than traditional TCP communications?


Provides absolute lowest latency
Highest throughput
Smallest CPU footprint
However, apps needed to be rewritten to take advantage of Infinibands low latency
Does this only work with InfiniBand?
No, iWARP supports RDMA over TCP/IP with iWARP-enabled Ethernet NICs
91
Copyright 2014 Hewlett-Packard Development Company, L.P. The information contained herein is subject to change without notice. Authorised HP Channel
Partners Only
Why RoCE?

Simplifies management Application


One wire, one network
Similar performance to

Latency & CPU%


Infiniband TCP
Data Center Bridging, set of IEEE Application
standards that create a lossless Application
fabric on top of Ethernet
OFA s/w IP
RDMA works best when the OFA s/w
underlying wires implement a IB Transport
lossless fabric IB Transport DCB
w/Ethernet Ethernet link,
Does not routinely drop packets IB Link, PHY PHY
link, PHY
DCB requires that your switches
Infiniband RoCE TCP/IP Ethernet
and NICs implement the important
parts of these new IEEE
92 specifications
Copyright 2014 Hewlett-Packard Development Company, L.P. The information contained herein is subject to change without notice. Authorised HP Channel
Partners Only
Available

Small packet processing


Description Is What is the Does What it Means Customer Associated
new, unique does function value statement, Quants/Claims
differentiator benefit
Substantiation in Notes
Pages
The new HP Over 7 million Mobile devices Increased network Up to 4 X improvement
FlexFabric Adapter small packets per drive significantly efficiency, which is in small packet
556FLR-SFP+ and second without smaller transaction critical for mobile processing performance.
CN1200E PMD/DPDK sizes in todays device traffic and
controllers 4 times data center. transaction-
significantly improvement of the The new HP heavy/clustered
improves small performance of FlexFabric Adapter applications such as
packet performance. previous hardware was video content delivery,
generation. architected to Web-scale applications
improve small and messaging
packet performance applications.
driven by these
mobile devices.

93
Copyright 2014 Hewlett-Packard Development Company, L.P. The information contained herein is subject to change without notice. Authorised HP Channel
Partners Only
Available

Embedded LOM on DL servers


Description Is What is the Does What it Means Customer Associated
new, unique does function value statement, Quants/Claims
differentiator benefit
Embedded quad- ProLiant Gen9 Provides entry-level Lower cost connectivity None.
and dual-port DL360/380 servers Ethernet
adapters on DL and will support both connectivity
ML platforms. FlexibleLOM slots included in the
and embedded price of the server.
1GbE quad-port
adapter
DL160/180
servers will
support just the
embedded 1GbE
dual-port adapter

94
Copyright 2014 Hewlett-Packard Development Company, L.P. The information contained herein is subject to change without notice. Authorised HP Channel
Partners Only
Available

InfiniBand adaptors for HP servers


Available as PCIe 3.0 cards, FlexibleLOM adaptors, and Mezzanine cards (for HP
BladeServers)
Description Is What is the Does What it Means Customer Associated
new, unique does function value statement, Quants/Claims
differentiator benefit
InfiniBand is a high-
speed interconnect
used within data Together with the next
centers typically for All the cards are generation of HP FDR InfiniBand at 56 Gb/s
HPC cluster systems dual ported, dual InfiniBand FDR edge provides over 4X the
and big data function cards switches, these speed of common 10
analytics (InfiniBand and adaptors deliver Gb/s Ethernet
Based on next- Ethernet). The highest speed
ConnectX-3 Pro generation Mellanox FlexibleLOM and InfiniBand bandwidth,
Dual-port InfiniBand ConnectX-3 Pro PCIe versions can up to 56 Gb/s (FDR) or
and Ethernet technology for also provide mixed up to 40 Gb/s (QDR),
adaptors scalability and fabric functionality for low-latency,
flexibility (InfiniBand and performance driven
Ethernet) server and storage
Connect-IB Based on next- Provides InfiniBand- clustering applications Dual-port FDR InfiniBand
Dual-port InfiniBand generation Mellanox only connectivity. in High Performance implementations provide
adaptors ConnectIB technology All the cards are Computing (HPC) and up to 100 Gb/s total
(with Dual-port FDR for FDR and QDR dual ported enterprise data centers bandwidth per adaptor
InfiniBand InfiniBand connectivity capable.
95capability) including Dual-port
Copyright 2014 Hewlett-Packard Development Company, L.P. The information contained herein is subject to change without notice. Authorised HP Channel
FDR InfiniBand
Partners Only
Flexible choice in
server configurations

Copyright 2014 Hewlett-Packard Development Company, L.P. The information contained herein is subject to change without notice.
Available

HP Universal Media Bay


Description Is What is Does What it Means Customer Associated Quants/Claims
the new, does function value statement,
unique benefit
differentiator
The HP Universal Provides a host Customer can now The HP Universal Media N/A
Media Bay is an of multimedia add up to two Bay allows users the
optional bay that and storage additional SFF SAS flexibility and choice to
provides options to or SATA HP expand their servers
multimedia or choose from. SmartDrives or a multimedia and storage
storage DVD-RW/USB port capabilities.
expansion kit or a VGA/USB
capabilities for port kit.*
your DL360 or
* DL380
PleaseGen9
see server QuickSpecs as options vary by server
servers.

97
Copyright 2014 Hewlett-Packard Development Company, L.P. The information contained herein is subject to change without notice. Authorised HP Channel
Partners Only
Available

HP Flexible Smart Array


Description Is What is Does What it Means Customer Associated Quants/Claims
the new, does function value statement,
unique benefit
differentiator
Smart Array Flexible Smart Choice of using the Address unique Flexibility provided to
Controller in a Array Smart Array requirements based on customers to select the right
flexible form PCIe device Controller or the workload controller to match the
factor that does not Smart HBA as the Does not occupy a workload and meet acquisition
occupy a PCIe main storage PCIe slot budget and allow flexibility to
slot in a controller upgrade or transition to newer
server technology when it becomes
available.

98
Copyright 2014 Hewlett-Packard Development Company, L.P. The information contained herein is subject to change without notice. Authorised HP Channel
Partners Only
Available

HP Flexible Capacity
Terms used Definitions/Benefits Reference Associated Quants/Features
in Gen9
messaging
HP Flexible Flexible Capacity is hybrid HP Datacenter Care Enable capacity ahead of demand
Capacity ready for the new HP Helion Flexible Capacity B for those types of workloads where the
Public Cloud. rochure application has business-sensitive data
HP Datacenter Flexible Capacity offers Pay as You Grow so security and compliance is critical
Care Flexible enterprise-quality support: and you want the infrastructure on
Capacity You can extend the their own site.
enterprise-quality support you Datacenter Care Fle Acquisition of new capacity is faster
get with Flexible Capacity to xible Capacity on h because the procurement process does
your hybrid cloud resources p.com not have to be started all over again for
using HP Hybrid Cloud each request.
Support. With Hybrid Cloud HP continuously optimizes the existing
Support, you gain rapid capacity, ensuring sufficient
access to hybrid cloud standby capacity.
experts, tools, and best
practices. This in turn helps
you achieve SLAs, reduce risk,
improve TCO, and maximize
responsiveness to critical IT
issues.

99
Copyright 2014 Hewlett-Packard Development Company, L.P. The information contained herein is subject to change without notice. Authorised HP Channel
Partners Only
Management

Copyright 2014 Hewlett-Packard Development Company, L.P. The information contained herein is subject to change without notice.
Available

HP OneView
Description Is What is Does What it does Means Associated Quants/Claims
the new, function Customer value
unique statement,
differentiator benefit
Converged Eliminating Automates the delivery IT Pros: SDx Complete deployment of a
management infrastructure and operations of IT approach to Hyper-V cluster in 5 easy
designed to complexity services, transforming infrastructure steps as compared to 15
accelerate IT with everyday management of management helps complex steps
operations for automation server, storage and reduce server 50% reduction in the tools
managing simplicity. network resources in configuration and to learn, manage, deploy and
servers, physical and virtual manual deployment integrate
storage, and environments. time while Automated cluster creation is
network Based on the unique speeding more than 6x faster than
resources. Fusion architecture provisioning and with current server, SAN and
featuring a software- delivery of storage management tools.
defined approach to infrastructure There can be 66x faster
converged management components. Thus service delivery with simple
that shifts the focus from improving IT staff automation, saving admin
devices to how people efficiency and time and reduced errors from
work. speed. manual steps.
An intelligent automation 40% less staff time for
hub that provides out-of- IT BDMs: SDx is the build and maintenance
the-box integration with approach that IT operations
HP, VMware, Microsoft, must adopt to meet 4 API commands, infinite
Red Hat solutions and easy business SLAs, and possibilities
Copyright 2014 Hewlett-Packard Development Company, L.P. The information contained herein is subject to change without notice. Authorised HP Channel
101
integration with many accelerate IT Provision infrastructure for
Partners Only
Available

HP OneView cont.
Description Associated Quants/Claims

Converged HP OneView takes about 30 seconds and 4 steps vs. UCS takes about 2 hours and >480
management steps to retire a network of 160 servers.
designed to Network configurations are 24x faster
accelerate IT Configure servers 96x faster
operations for BladeSystem with HP OneView delivers approximately 40% lower TCO
managing 220% ROI and 6 month payback
servers, storage, Migrate workloads 5x faster
and network 42% lower TCO
resources. Reduce IT acquisition costs up to 41%
Reduce IT management operational costs by 54%
Reduce datacenter hardware costs by 50%
Reduce datacenter electricity usage by 13% (OpEx)
Single management view vs. dozens of separate views
Deploy servers approximately 23% less time
Migrate physical workloads 3x faster
A single, integrated management platform up and running 20x faster
Deploy BladeSystem infrastructure 45% faster
Complete deployment of a VMware vSphere cluster in 5 easy steps as compared to 15
complex steps
Deliver infrastructure and application services in minutes
Seconds to provision VMs for the cloud

102
Copyright 2014 Hewlett-Packard Development Company, L.P. The information contained herein is subject to change without notice. Authorised HP Channel
Partners Only
On premise management with HP
OneView
Converged, Infrastructure Lifecycle software
Management defined Application
Application control
control Rapid, repeatable
User
User control
control
and reliable
Admin
Admin control
operations at lower
control
software
software defined
defined
management
costs using
management
Common
Common Building Blocks
Building Blocks

infrastructure
HP
OneView templates.
Converged, Partner Automated
Integrations
Streamlined
delivery of IT
services to speed
the transition to
hybrid cloud.

Eliminate complexity with automation simplicity

103
Copyright 2014 Hewlett-Packard Development Company, L.P. The information contained herein is subject to change without notice. Authorised HP Channel
Partners Only
HP OneView
Closed-loop automation with HP Software and Third-Party Vendor
Partners
I have to support
dozens of remote Automate HP OneView monitors
offices. I want the Trouble environment & IDs HP Service
system to changes to status as Manager
Ticket to
generate trouble publisher
Service (service desk)
tickets for me. Desk is notified
I need to spend VMware
less time HP OneView plug-in vCenter
deploying maximizes console is the
End-To-End
infrastructure and investments in 3rd- consumer
Cluster
more time Party management
Deployment consoles as publisher 1.Start wizard 4.Press go
deploying 2.Select template 5.Check results
workloads. 3.Enter IP addresses

Once Ive
deployed a new
asset, I need to Automate HP OneView enables
reductions in time, effort
HP uCMDB is
catalogue it, New Asset the
depreciate it and and errors of asset
Registratio management as consumer
track changes ns publisher
over time.
104
Copyright 2014 Hewlett-Packard Development Company, L.P. The information contained herein is subject to change without notice. Authorised HP Channel
Partners Only
HP OneView Integrated Licensing
Receive HP Insight Control entitlement rights with HP OneView license
Policy
purchase
All HP OneView (future and existing) customers may
obtain HP Insight Control licenses in the same
quantity at no additional charge (no price or part number
changes).
New purchases just log in to HP licensing portal (
www.hp.com/software/licensing)
Existing customers take their Support Agreement ID (SAID) to HP
HP OneView License software updates*
Usage Rights for HP Allows HP OneView OR HP Insight Control license
Insight Control entitlement
3-Years HP OneView TS&U
Not both simultaneously
Now I can Customer can move from HP Insight Control to HP OneView at any
move to HP time
OneView at ALL HP OneView license SKUs are eligible except HP OneView
my pace Upgrade licenses
*https://h20575.www2.hp.com/tsusbportal/index.d (HP Passport account required, or a new
Three
account Year
created) Technical Support and Software Updates
Note: Usage rights do not extend to VCEM since HP OneView v1.10 contains key VC functionality
105 (TS&U)
Copyright 2014 Hewlett-Packard Development Company, L.P. bundled
The information contained herein is subject to change without notice. Authorised HP Channel
Partners Only
Available

REST API with OneView


Terms used Definitions Reference Associated Quants/Key Features
in Gen9
messaging
REST API with HP OneView provides HP OneView REST APIs provide a simpler, stateless,
HP OneView Fast and modern user 1.10 Frequent and scalable approach, so users can
interface for users, and an ly Asked Quest easily integrate, automate, and
open development ions customize on their own.
platform using the A consistent API, a common data model,
REpresentational State and a state-change message bus
Transfer application-
programming interface
(REST API).
Designed for those who
wish to access full power
of the management
architecture.
Developers in the
ecosystem are also
interested in REST APIs,
because they are
common to two-thirds of
todays top Web
environments.

106
Copyright 2014 Hewlett-Packard Development Company, L.P. The information contained herein is subject to change without notice. Authorised HP Channel
Partners Only
Available

Unified Extensible Firmware Interface


(UEFI)
Description Is What is the
new, unique
Does What it does
function
Means Customer
value statement,
Associated
Quants/Claims
differentiator benefit
(feature) Substantiation in Notes
Pages
Unified HP ProLiant Gen9 HPs ProLiant System BIOS Industry standard server 50% reduction in
Extensible Servers BIOS default is a UEFI solution based on configuration method server boots
Firmware mode EDK2 and adheres to the requiring less reboots
Interface latest revisions of UEFI after configurations.
(UEFI) is an specifications
industry
standard set UEFI Class 2 solution Supports both legacy boot Flexibility to switch
of interfaces and UEFI boot mode. between legacy and UEFI
between the boot mode
system EDK2 and adheres to Provides additional Expand storage
firmware and the latest revisions of functionality not available capacity during
the operating UEFI specifications with Legacy BIOS system booting to
system, and support > 2.2TB drive.
between IPv6 PXE Boot allows a
various unified network stack
components to PXE boot from
of the system any network
firmware controller. Also
allowing you Supports IPv4 PXE.
to configure PXE Multicast boot
one
107 server2014
Copyright at Hewlett-Packard Development Company, L.P. The information contained herein is subject to support fornotice.
change without image Authorised HP Channel
a Partners
time. Only deployment in
Available

UEFI (continued)
Description Is What is the Does What it does Means Customer Associated
new, unique function value statement, Quants/Claims
differentiator benefit
(feature)
Unified Secure Boot Secure Boot is a UEFI Protect against Increase server
Extensible standard function ensuring unauthorized operating security with 4 new
Firmware only authenticated option systems and malware levels of Secure Boot2
Interface ROMs, applications, and OS attacks
(UEFI) is an boot loaders that have
industry been digitally signed are
standard set run.
of interfaces
between the UEFI Shell UEFI Shell is an embedded Based on the UEFI Shell
system command line interface Specification 2.0 and
firmware and (CLI) tool in the System enhanced with an
the operating ROM for scripting, file extended command set
system, and manipulation, obtaining for additional
between system information, or functionality and
various running other UEFI customized scripting
components applications.
of the system HP RESTful API Industry recognized Modern intelligent
firmware architectural style, for manageability interface
allowing you server standardized and lightweight data
to configure interaction to configure at model specification that
one server at scale using a HTTPS web is simple, remote,
108a time.
Copyright 2014 Hewlett-Packard Development Company, L.P. protocol
The information contained herein is subjectsecure, and notice. Authorised HP Channel
to change without
2
Partners
Secure Boot Onlyof all UEFI Drivers, any UEFI applications, OS Bootloaders and Linux Kernel Modules. HP Labs, Houston,
authentication inclusive extensible.
TX, July 2014
What is Unified Extensible Firmware
Interface (UEFI)?

Better Manageability with


industry standard interface
Enhanced Security Feature
with Secure Boot
Industry standard set of interfaces
Reduced Bootime while between system firmware and operating
configuring the server system, and between various
components of system firmware
109
Copyright 2014 Hewlett-Packard Development Company, L.P. The information contained herein is subject to change without notice. Authorised HP Channel
Partners Only
Available

HP SUM 7.1.0
Description Is What is Does What it Means Customer Associated Quants/Claims
the new, does function value statement,
unique benefit
differentiator
(feature)
HP SUM is the iLO Federation Automatically Firmware update
engine that discover and scalability capabilities
deploys smart update all
components for applicable
maintenance on firmware the iLO
HP ProLiant Federation Group
Servers, Integrity via the iLO using
Servers, offline firmware
BladeSystem deployment
infrastructure, HP Ability to update
Moonshot Servers the iLO and ROM
and related firmware online
options one or on HP ProLiant
many at a time. servers in the iLO
Federation Group
via the iLO 4 1.40

Live logs View deployment Provide detailed


logs during the information of target
to change without notice. Authorised HP Channel
110
Copyright 2014 Hewlett-Packard Development Company,deployment update
L.P. The information contained herein process
is subject
Partners Only process
Available

HP SUM 7.1.0
Description Is What is Does What it does Means Customer Associated
the new, function value statement, benefit Quants/Claims
unique
differentiator
(feature)
HP SUM is the Custom Baselines Filter by server model Update specific node items
engine that Dynamic filters for
deploys smart package selection based
components for on the packages in the
maintenance on baseline
HP ProLiant Filter to create an HP
Servers, Integrity CloudSystem Matrix
Servers, custom baseline
BladeSystem
infrastructure, HP Add Baseline Enhanced the ability to Reduce the amount of time
Download a baseline from downloading a baseline
Moonshot Servers
and related an HTTP server
Abort downloading a
options one or
many at a time. baseline from hp.com or
an HTTP server
Support for Linux Added localization support Additional support for Linux
package for Linux package environment
configuration
Delete Baseline Enhanced Delete Baseline Report and confirms which
111 to nodes are referencing the
Copyright 2014 Hewlett-Packard Development Company, L.P. The information contained herein is subject to change without notice. Authorised HP Channel
Partners Only baseline to be deleted
HP Smart Update solution
SPP and HP SUM take the pain out of firmware and driver
maintenance maximizing:
Stability with a unified solution composed
of firmware, driver and agents that are
tested and encoded interdependent

Uptime with Online Updates for all


Windows, Linux and growing number of
VMware ESXi/vSphere 5 updates requiring a
single reboot to activate

Supportability with detail reporting or 1


year full support for every SPP, mixed
enclosures, or baseline customizations
112
Copyright 2014 Hewlett-Packard Development Company, L.P. The information contained herein is subject to change without notice. Authorised HP Channel
Partners Only
Denotes new or improved for Gen9
HP Smart Update Technology
A smart solution for solid results
Smart components SPPs and bundles HP Smart Update Manager
Windows (self-extracting Collections of smart Preferred engine for
executables) components with special deployment of HP system
Linux (RPMs, self- XML file, usually by OS or software updates
contained exes scexes) product Easy to use with Graphical UI,
VMware (self-contained All components and CLI and interactive CLI modes
exes scexes, zips) bundles are tested as a Scalable updates with iLO
set Federation technology
HP-UX (self-contained
exes scexes) Downloadable from the Local and remote updates
web
Individually versioned Dependency checking,
HP SUM is embedded in installation ordering
Contain one or more
the bundle as the
payloads that are Dynamic Baseline
deployment engine
installed together as a set customizations
Plan system maintenance
Reporting
two times a year with the
Maintenance Supplement Supports ProLiant / Integrity
113
i2notice.
Copyright 2014 Hewlett-Packard Development Company, L.P. The information contained herein is subject to change without
Bundle (MSB) and i4 servers,
Authorised HP c-Class/
Channel
Partners Only
HP Scripting Tool for Windows
PowerShell
Take your PowerShell automation to the next level
Consistent and reliable server configuration
HP Scripting Tool for Windows PowerShell aligns with consistent interface
and provide large set of commands for HP servers
All HP PowerShell cmdlets have built-in Help functions that document
syntax and usage examples
Fast and effective HP Server configuration
Configuration management framework fromMicrosoft , consisting of
acommand-lineshelland associatedscripting languagebuilt on the.NET
Framework
Object oriented output from one command can be passed to another
via pipe command
Our HP iLO and HP OA PowerShell modules provide comprehensive
configuration management that are easily invoked through runbook
114 automation tools.
Powerful and consistent infrastructure
Copyright 2014 Hewlett-Packard Development Company, L.P. The information contained herein is subject to change without notice. Authorised HP Channel
Partners Only management
HP Scripting Tools for Windows
PowerShell
Powerful Use
and consistent Casesmanagement
infrastructure

Microsoft and VMware users can run simple


scripts to:
PowerShell Onboard Administrator cmdlets Run PowerShell script that configures all of
enable retrieval of firmware versions from the settings for 1 to n iLO instances.
multiple enclosures and servers, and pipe
information to cmdlet(s) that updates
enclosures, blade, and enclosure options.

115
Copyright 2014 Hewlett-Packard Development Company, L.P. The information contained herein is subject to change without notice. Authorised HP Channel
Partners Only
Available

HP iLO 4 v2.00
Description Is What is Does What it does function Means Associated
the new, Customer Quants/Claims
unique value
differentiator statement,
(feature) benefit
HP iLO is the iLO Federation1 Built-In iLO Federation Discovery uniquely Discovery and Seconds to
core foundation recognizes numerous servers at once via management discover 100s of
and multicast discovery methods supporting both at scale via iLO servers2
intelligence of IPv4 and IPv6 environment providing the Groups
all HP ProLiant following information
servers. HP iLO Query and Display
functions out- Group health status
of-the-box Group configurations
without Server name registration
additional Minutes to update
software Full iLO Federation Management firmware across
installation implementation 100s of servers3
regardless of with an iLO Advanced or iLO Scale-Out
the servers' License
state of Group Firmware Update gives you the ability
operation. HP to update the firmware of multiple servers
iLO can be Group License Activation for faster
accessed from implementation of iLO licenses
any location via Group Power Capping allows servers to
a web browser share power consumption among a group of
1 or
116 the iLO
Backwardscompatible
Copyrightto2014
iLO 4 Hewlett-Packard
1.40 Development Company, servers
L.P. The information contained herein is subject to change without notice. Authorised HP Channel
2

3
mobile
PerformingPartners Only
iLO firmware updates
Group Power Control lets you turn several
Multi-casting method of communicating with 186 iLOs and discovering them in 3.693 seconds. Comparing it against our previous generations and competitors. Based on HP Internal estimates, Houston, TX, USA, July 2014
of 200 systems in 380 seconds. Comparing it against our previous generations and competitors. Based on HP Internal estimates, Houston, TX, USA, July 2014
Available

HP iLO 4 v2.00 (continued)


Description Is What is Does What it does Means Customer Associated
the new, function value statement, Quants/Claims
unique benefit
differentiator
(feature)
HP iLO is the core HP RESTful API1 Industry recognized Modern intelligent
foundation and architectural style, for manageability interface
intelligence of all server standardized and lightweight data
HP ProLiant interaction to configure model specification that
servers. HP iLO at scale using a HTTPS is simple, remote,
functions out-of- web protocol secure, and
the-box without extensible.
additional
software Embedded User HP ProLiant Gen9 servers Additional user 1GB Embedded User
installation Partition2 with a 4 GB iLO NAND utilization or storage Partition in Gen9 servers
regardless of the allow you to use a 1GB space
servers' state of non-volatile flash
operation. HP iLO memory partition as if it
can be accessed was an SD-card attached
from any location to the server; accessible
via a web browser through the server
or the iLO mobile operating system when
application to enabled.
manage one or iLO Reboot Reset the iLO or HP Gracefully turn the
many servers. Switch2 ProLiant hardware via the server on or off.
117
UID
Copyright 2014 Hewlett-Packard Development Company, L.P. button in the
The information case herein is subject to change without notice. Authorised HP Channel
contained
Partners Only where iLO may not be
Available

HP iLO 4 v2.00 (continued)


Description Is What is Does What it does Means Associated Quants/Claims
the new, function Customer
unique value
differentiator statement,
(feature) benefit
HP iLO is the core Pre-boot health Diagnostic screen through Faster server
foundation and summary1 the servers external monitor troubleshooting
intelligence of all prior to powering on and diagnostics
HP ProLiant demonstrating:
servers. HP iLO server data, iLO access
functions out-of- information, firmware
the-box without versions and critical
additional Integrated Management Logs
software (IML).
installation
regardless of the Agentless New Agentless data now Additional
servers' state of Management visible. server
operation. HP iLO External storage attached monitoring
can be accessed to the Smart Array: through the iLO
from any location Provides Health status and GUI
via a web browser serial number
or the iLO mobile Gen9 HP Branded HBA
application to storage support: Provides
manage one or Health status, model,
many servers. serial number & firmware
The information contained herein is subject to change without notice. Authorised HP Channel
118
Copyright 2014 Hewlett-Packard Development Company, L.P.version
1
Partners
Not backwards compatible Only Monitors status of Smart
Available

HP iLO 4 v2.00 (continued)


Description Is What is Does What it does Means Customer value Associated
the new, function statement, benefit Quants/Claims
unique
differentiator
(feature)
HP iLO is the core iLO Mobile App Update for iOS7 Additional support/features
foundation and Version 1.06 out now to manage your server from
intelligence of all Added views optimized your mobile device.
HP ProLiant for tablets
servers. HP iLO New virtual keyboard
functions out-of- All views updated for
the-box without iOS 7
additional Update for Android
software Updated for KitKat
installation (Android 4.4)
regardless of the Updated for hardware
servers' state of accelerated encryption
operation. HP iLO
can be accessed iLO Integrated The iLO Integrated Remote server
from any location Remote Console 1
Remote Console is a management capabilities
via a web browser graphical remote console anytime, anywhere with
or the iLO mobile that turns a supported internet connection.
application to browser into a virtual
manage one or desktop, allowing full
many servers. control over the display,
of is subject to change without notice. Authorised HP Channel
119
Copyright 2014 Hewlett-Packard Development Company, L.P. keyboard, andcontained
The information mouseherein
Partners
uires an iLO license Only
for specific features. Please read the iLO Family Guide for more details.
the host server.
Available

HP iLO 4 v2.00 (continued)


Description Is What is Does What it does Means Customer value Associated
the new, function statement, benefit Quants/Claims
unique
differentiator
(feature)
HP iLO is the core iLO Virtual Media1 Enables a user to use the Deploy servers remotely
foundation and Virtual Media feature on reducing travel cost
intelligence of all the host system.
HP ProLiant
servers. HP iLO iLO Licensing (iLO Provides additional Better remote and security
functions out-of- Advanced, iLO functionality and features. management capabilities
the-box without Advanced for Refer to the
additional BladeSystem, iLO iLO Family Guide for a
software Scale-Out, iLO comparison of the
installation Essentials different types of
regardless of the features.
servers' state of
operation. HP iLO
can be accessed
from any location
via a web browser
or the iLO mobile
application to
manage one or
many
120 servers.
Copyright 2014 Hewlett-Packard Development Company, L.P. The information contained herein is subject to change without notice. Authorised HP Channel
Partners
uires an iLO license for Only
specific features. Please read the iLO Family Guide for more details.
Whats new with HP iLO 4 v2.00

iLO Tiering impacts:


Depending of server configurations, requires an add-on
for iLO management port.
4GB NAND have a 1GB Embedded Customer Partition
Check server configurations for more details.
iLO Reboot Switch-iLO reset button
Pre-boot health summary-AUX video
Also:
iLO Federation-discovery and
iLO 4 v2.00 supports both Gen8 and
management via iLO Groups Gen9 servers
Agentless Management- NIC and Smart 58 servers to be supported by iLO 4
Array v2.00
iLO Mobile App Customer-oriented plan

121
Copyright 2014 Hewlett-Packard Development Company, L.P. The information contained herein is subject to change without notice. Authorised HP Channel
Partners Only
Available

HP RESTful Interface Tool


Descripti Is What is the Does What it does function Means Customer value Associated
on new, unique statement, benefit Quants/Clai
differentiator ms
(feature)
HP RESTful Single Command Line The CLI lets you interact with Single Command Line Interface
Interface Interface server components for easier scripting and
Tool is a and customize scripting at scale simplify customized workflows
command leveraging industry recognized HP
line RESTful APIs
interface
(CLI) for HP RESTful API Self-descriptive tool Faster adoption reducing the
BIOS (UEFI) exposing all kind of server data learning curve adoption
configurati Remote Manageability Securely log in and script from Reduced travel cost
on of one remote locations without the need
or many of a remote console. Capabilities
Gen9 leveraging industry-proven HTTPS
servers at protocol
a single
time. 3 Modes of operation 1. Interactive mode provide Reduced deployment to
autocomplete capabilities. program and execute scripts
2. Scriptable mode script all quickly
the commands by letting users
get and set properties of server
objects or input files.
3. File-based mode allows users
Copyright 2014 Hewlett-Packard Development Company, L.P. The information contained herein is subject to change without notice. Authorised HP Channel
122
of HPREST to save and load
Partners Only
HP RESTful Application Programmable
Interface (API) Simplicity
Easier access to information to run management
scripts and provision server at scale
Enable a common tool
Programmatic interface with a public facing API

Remote & Secure


Capabilities leveraging industry-proven HTTPS
protocol

Extensible
Ability to script and expose current or new
functionality with few or no firmware upgrade
dependencies
Easy to implement & consume
Modern intelligent manageability interface and lightweight data model specification that is simple,
123 remote, secure, and extensible.
Copyright 2014 Hewlett-Packard Development Company, L.P. The information contained herein is subject to change without notice. Authorised HP Channel
Partners Only
Standard architecture via HP RESTful API
HP RESTful API reduces complexity ofconnectorsemantics
Before With HP RESTful API After

Software
Applicati
Defined on
Enterpris control
e
Representational state transfer (REST) is a way to create, read, update, or delete information on a
server using simple HTTPs calls.

The RESTful Application Programming Interface (API) is an architectural style consisting of a


coordinated set of architectural constraints applied to components, connectors, and data elements within a
distributedhypermedia system. Implementation options
Direct Programming Single Scripting Tool
Non HP Tools HP RESTful Interface Tool
Write your own integration in iLO or
UEFI
Web app -HTTPS Protocol
124
Authorised
Settings HP Channel
take effect
Copyright 2014 Hewlett-Packard Development Company, L.P. The information contained herein is subject to change without notice. after
Partners Only
HP RESTful Interface Tool
Simple
Single Command Line Interface (CLI) with standard
set of commands to interact with all the server
components and customized scripting at scale

Remote
Securely log in and script from remote locations
without the need of a remote console. Capabilities
leveraging industry-proven HTTPS protocol

Optimal
Quickly script and expose new functionality with few
or no firmware upgrade dependencies

125
Single Command Line Interface for easier scripting
Authorised HP Channel
Copyright 2014 Hewlett-Packard Development Company, L.P. The information contained herein is subject to change without notice.
Partners Only
HP RESTful Interface Tool
Key Features

Single command tool to configure BIOS


Provide remote capabilities.
HP RESTful API Interface tool has 3 modes of
operation:
1. Interactive mode started when the user runs
HPREST without any command line parameters. The
user is then entered into a hprest> prompt where
they may enter commands one at a time. They can
exit the interactive mode by entering the exit
command at the prompt.
2. Scriptable mode used if the user want to script all
the commands with the use of an external input file.
The script contains a list of HPREST command lines
that let users get and set properties of server
objects.
3. File-based mode allows users of HPREST to save
and load settings from a file. This is similar to the
conrep.dat files used by CONREP. File-based mode
126 supports
Copyright both XML
2014 Hewlett-Packard and JSON
Development formats.
Company, L.P. The information contained herein is subject to change without notice. Authorised HP Channel
Partners Only
Available

HP Service Pack for ProLiant (SPP)


2014.09.00
Description Is What is
the new,
Does What it
does function
Means Customer
value statement,
Associated Quants/Claims

unique benefit
differentiator
(feature)
SPP is a SPP Maintenance SPP MSB release Establishes a cadence
packaging and Supplement April and October to update your server
collection product Bundle (MSB)
of firmware,
drivers and Smart
Components for
HP ProLiant
Servers & Blades
Infrastructure.

127
Copyright 2014 Hewlett-Packard Development Company, L.P. The information contained herein is subject to change without notice. Authorised HP Channel
Partners Only
Available

Intelligent Provisioning v2.0


Description Is What is Does What it does Means Customer Associated
the new, function value statement, Quants/Claims
unique benefit
differentiator
Intelligent Opt-in Access to Allows customers to opt-in Faster access to free
Provisioning 1TB of free VSA and run the software to 1TB HP StoreVirtual
provides simple install the 1TB of free VSA VSA
system post OS deployment
configuration and
OS installation for Insight HP Insight Diagnostics Faster problem
one server at a Diagnostics captures system diagnosis
time. configuration information
and provides detailed
diagnostic
testing capabilities
Active Health AHS provides continuous, Faster problem
System (AHS) proactive health monitoring resolution when
of over 1600 system calling HP Support
parameters
Support all the Support all the new Gen9 Continue using
new Gen9 platforms, options and OSes Intelligent Provisioning
platforms, support for Gen9 server
options and deployment and OS
OSes support installation
The information contained herein is subject to change without notice. Authorised HP Channel
128
Copyright 2014 Hewlett-Packard Development Company, L.P.
Partners Only
HP Intelligent Provisioning Overview
Quickly and easily go from out-of-box into production

System and HP ProLiant


OS System SW
Simplified and Embedded System
Configuration with Wizard
Faster deployment than with
traditional media and pre-loaded with
HP system software, utilities and tools
Flexible Deployment Settings

Replaces SmartStart CDs

Intelligent Provisioning provides simple system configuration for faster provisioning


129
Copyright 2014 Hewlett-Packard Development Company, L.P. The information contained herein is subject to change without notice. Authorised HP Channel
Partners Only
Intelligent Provisioning
Whats New in Gen9
Simplified graphical user interface
(GUI) with guided, profile-driven
approach:
Seamless integration with standard IT
processes
Simplified Recommended and Custom
Install
Streamlined Manual Install
Faster access to FREE 1TB HP StoreVirtual
VSA software with Opt-in feature
Supported OSes
Windows
Linux
VMware vSphere
Support for all Gen9 servers & options

130
Copyright 2014 Hewlett-Packard Development Company, L.P. The information contained herein is subject to change without notice. Authorised HP Channel
Partners Only
HP Intelligent Provisioning product
features
Configuration and Deployment Maintenance Features
Features Active Health System log
Configuration of Smart Array & software Insight Diagnostics
RAID Application of BIOS settings and System Erase
quick configs iLO Configuration
OS installation of x64 Linux, Windows, Deployment Settings: USB,
and VMware iLO, STK
Manual Installs (no drivers/configuration) HP SSA
Recommended (Kickstart, AutoYast, Firmware and IP Image Update
AutoUnattend)
Quick Configs
Installation of critical drivers with OS
Remote Support
Update firmware with OS install (pull
from web)
Version
HP StoreVirtual 1.6x supports VSA software Gen8 servers; Version 2.x supports Gen9 and
opt-in
future
(v2.01)
131 products
Copyright 2014 Hewlett-Packard Development Company, L.P. The information contained herein is subject to change without notice. Authorised HP Channel
Partners Only
Available

HP Insight Online
Description Is What is Does What it Means Customer Associated Quants/Claims
the new, does function value statement,
unique benefit Substantiation in Notes Page
differentiator
HP Insight Online Mobile Personalized Save time and Up to 90% time savings
is a cloud-based dashboard via online & mobile resources, and reduce tracking contracts,
infrastructure the HP dashboard for downtime with warranties and device
management and Support simplified increased efficiency configurations
support portal Center Mobile tracking of IT Save time with 50% service call time
available through App operations and efficient contract, reduction 66% less
the Gen9 support support warranty, case and unplanned downtime
HP Support Cente New UI information service credit Up to 66% faster problem
r interface, Track service management resolution vs traditional
and powered by integration events & support Decrease costs with support processes
HP remote with HP cases, view 24x7 monitoring,
support OneView and asset automated cases and
technology 3Par configurations, parts replacement
(Insight Remote (Q2/2015) monitor
Support or direct Expanded contracts, Reduce risk by fixing
connect). Proactive Care warranties & problems faster and
Supports the features service credit reducing downtime
converged balances.
infrastructure of 24x7 remote
servers, storage monitoring, fast
and networks diagnosis, case
Copyright 2014 Hewlett-Packard Development Company, L.P. The information contained herein is subject to change without notice. Authorised HP Channel
132
creation and
Partners Only
HP Insight Online
Access IT infrastructure information anytime, anywhere
24x7 automated event
monitoring
Automated case creation and faster
resolution
Proactive parts replacement
Simple all-in-one access on
your terms
Secure, comprehensive view
Anytime, anywhere, any device
Stay informed and in control
Save time and resources for quicker
resolution
Servers Storage Network
One interface for IT health and support
133
management
Copyright 2014 Hewlett-Packard Development Company, L.P. The information contained herein is subject to change without notice. Authorised HP Channel
Partners Only
Gen9 launch availability

Gen9 support at launch Gen9 support with 7.1


(excludes Apollo) patch
(excludes Apollo)
134
Copyright 2014 Hewlett-Packard Development Company, L.P. The information contained herein is subject to change without notice. Authorised HP Channel
Partners Only
Example: Automate case management & parts
replacement
HP Insight Online monitors 24X7, transmits events, opens cases
and schedules part replacement or service
I have 5 Insight Online -
Custom
Bladesystem My IT
er Environment
s in different 00.
sites. I want
the systems HP
to report Support
HP ProLiant Problem
problems Gen8 and
diagnosed Insight Online
directly to forward
My Customers
my service Component and case Partner
provider failure opened
detected
Part
identified
& shipped
or service Track events &
scheduled case status in the
dashboard
Save time and resources for quicker
135
Authorised HP Channel
Copyright 2014 Hewlett-Packard Development Company, L.P. The information contained herein is subject to change without notice.
Partners Only resolution
Insight Online for Converged
Infrastructure
Save time and resourceswith
Futures
automation and simplified information
access
Connected products
Q2/2015

HP Insight
Remote Support HP
OneView

Refreshed User Interface Direct connect for


HP ProLiant 3Par visibility
Integration with HP OneView & 3Par Gen8/9
Automated C&W refresh
Onboarding: Gen9, HanaHawk, DL580
based Hana solution
Onboarding H1/2015: XP, NonStop
136
Copyright 2014 Hewlett-Packard Development Company, L.P. The information contained herein is subject to change without notice. Authorised
HP HP Channel
Confidential
Partners Only
Security

Copyright 2014 Hewlett-Packard Development Company, L.P. The information contained herein is subject to change without notice.
Available

UEFI Secure Boot


Description Is What is Does What it Means Customer Associated Quants/Claims
the new, does function value statement,
unique benefit
differentiator
Secure Boot a New to Secure Boot Protects against Increase server security with
UEFI standard ProLiant Gen9 authentication unauthorized operating 4 new levels of Secure Boot
function to servers inclusive of all UEFI systems and malware
ensuring only Drivers, any UEFI rootkit attacks,
authenticated applications, OS
option ROMs, Bootloaders and
applications, and Linux Kernel
OS boot loaders Modules.
that have been
digitally signed
are run.

138
Copyright 2014 Hewlett-Packard Development Company, L.P. The information contained herein is subject to change without notice. Authorised HP Channel
Partners Only
Available

Serviceguard for Linux


Description Is What is the Does What it Means Customer Associated
new, unique does function value statement, Quants/Claims
differentiator benefit
HP Supports SAP HANA Monitors HP Serviceguard As low as 4 seconds
Serviceguard - eliminates availability of Solutions for Linux: server recovery with
Solutions for complex manual critical apps, Provides fast HP Serviceguard
Linux recovery services, failover and As low as Zero
protects procedures and databases, and recovery, even in planned downtime
your critical minimizes custom apps over large clusters As low as 2 minute
applications unplanned any distance. Protects against disaster recovery
from downtime If faults are disasters and major Nearly eliminate all
planned and Redesigned detected, site outages, unplanned downtime in
unplanned Serviceguard Serviceguard for regardless of the Linux operating
downtime. Manager for Linux Linux distance environments
provides high level automatically and Reduces downtime
overview of transparently fails to zero during
multiple HP over those apps maintenance and
Serviceguard quickly and upgrades
clusters across a resumes normal
data center from a Ops without
single window compromising
data integrity and
performance.

139
Copyright 2014 Hewlett-Packard Development Company, L.P. The information contained herein is subject to change without notice. Authorised HP Channel
Partners Only
Available

HP Secure Encryption
Description Is What is Does What it Means Customer Associated Quants/Claims
the new, does function value statement,
unique benefit
differentiator
Controller-based Optional for both Encrypts the data Protects data moving Easy to use; no specialized
encryption the Smart Array through the use of in and out of cache as security training or
Controller and encryption keys well as data at rest certificate needed to
Smart HBA Works with all drive administer it
types Data is encrypted with the
Easy to use; no industry standard XTS AES
specialized security 256 bit algorithm.
training or certificate HP ESKM can scale up to
needed to administer 25,000 clients and 2M
it encryption keys.
Scalable from local Minimal impact to
mode to remote mode performance of the controller
HP ESKM provides the
central key
management

140
Copyright 2014 Hewlett-Packard Development Company, L.P. The information contained herein is subject to change without notice. Authorised HP Channel
Partners Only
HP Secure Encryption Controller based
encryption
Enterprise-class encryption solution for data at rest
Ideal Environments Customer Benefits
Financial, Healthcare, Government, Broad Encryption Coverage
Insurance, Travel, e-Commerce (Web 2.0), High Availability and Scalability
HR who need to protect private data Simplified deployment and management
Extra level of protection for sensitive data Meets Compliance Regulations like HIPAA
Compliments DMR, Decommissioning, and and Sarbanes-Oxley
Relocations
HP Secure Encryption
Maximum performance
Maximum performance

HP Secure Encryption is a controller-based data encryption solution for HP ProLiant


Gen9 servers that protects data at rest on any bulk storage attached to Gen9 HP Smart
Array and Smart HBA controllers running in RAID mode.
141
Copyright 2014 Hewlett-Packard Development Company, L.P. The information contained herein is subject to change without notice. Authorised HP Channel
Partners Only
HP Secure Encryption Deployment
Modes
Enterprise-class encryption solution for data at rest
Remote Mode (Automatic Storage /
Remote Mode (Automatic Storage /
Management) One Key Per Drive
Protection
Local Mode (Manual
Storage) One Key Per Controller
Protection
HP Enterprise iLO 4 HP Smart HP Smart Array HP
Secure Key Connectivi Storage Controller Px3x compatibl
Manager 3.1 ty Administrator e
Encryption HDD/SSD
Mgt.
Plain Text Encrypted Text
Servers

2 to 8

iLO
Networ
k
ESKM Cluster / Client License
ProLiant - Per Drive Encryption SKU (Single SKU applies to all drives )
per Server
Copyright 2014 Hewlett-Packard Development Company, L.P. The information contained herein is subject to change without notice. Authorised HP Channel
142

Partners Only
Power & Cooling

Copyright 2014 Hewlett-Packard Development Company, L.P. The information contained herein is subject to change without notice.
Available

HP Flexible Slot (Flex Slot) Power


Supplies
Description Is What is the
new, unique
Does What it
does function
Means Customer Associated Quants/Claims
value statement,
differentiator benefit
New, high New Flexible Slot HP's Flex Slot power Power density, 25% smaller footprint, as
efficiency Flexible form factor that supplies are certified efficiency, and compared to Gen8 Common
Slot Power supports HPs for high-efficiency flexibility Slot design, allowing for
Supplies with portfolio of AC, operation and offer space to add additional
options that DC, and high multiple power server options
provide up voltage output options, 25% improvement in power
to94% (Platinum) (HVAC/HVDC) allowing users to density (from 40 watt/in2 to
and 96% power supply "right-size" a power 50 watt/inch2) that provides
(Titanium) options supply for specific more server power in a
efficiency (1H15) Will also include server smaller space (predicting this
a battery backup configurations. This to be the highest power
(BBU) solution in flexibility helps to density solution in the IT
the Flexible Slot reduce power waste, industry)
form factor lower overall energy Support for highest efficiency
(1H15) costs, and avoid (96% 80+ Titanium)
"trapped" power recognized within the IT
capacity in the data industry
center. Readily available, off-the-
shelf high voltage AC and DC
power supplies considered
a special order with
competitors
The information contained herein is subject to change without notice. Authorised HP Channel
144
Copyright 2014 Hewlett-Packard Development Company, L.P.
Partners Only
HP Gen9 Rack & Tower Power Supply
Overview
Gen9 3xx Series
Focus on power density, efficiency, and flexibility
Moving from Common Slot to Flex Slot form factor
Default power efficiency is 94% , upgrade to 96% (available 1H2015)
Continued support for 48VDC & 380VDC (available 1H2015)
Support for Intelligent Power Discovery on select options

Gen9 1x/1xx Series


Focus on value optimization, balancing features and price
1U ATX form factor
80Plus Silver-certified non-redundant power supply with 89% efficiency
80Plus Gold-certified redundant power supply with 92% efficiency
(available 4Q2014)
100VAC-240VAC supported

145
Copyright 2014 Hewlett-Packard Development Company, L.P. The information contained herein is subject to change without notice. Authorised HP Channel
Partners Only
Flex Slot Power Supply Key Features
and Benefits
HP Flexible Slot Power Supply options provide up to 94% power efficiency
with 80Plus Platinum-certified power supplies that lower server power
requirements and reduce power waste in your data center.
New Flex Slot form factor is 25% smaller than previous generation
Common Slot power supplies, providing more space to add additional
server options and improve your IT performance.
Provides fast, tool-less hot plug access to server power supplies for
greater serviceability.
Supported across all ProLiant DL300 Gen9 series servers, simplifying your
spares strategy and reducing data center costs.

146
Copyright 2014 Hewlett-Packard Development Company, L.P. The information contained herein is subject to change without notice. Authorised HP Channel
Partners Only
Gen9 ProLiant Flex Slot Form Factor
Traditional design, but smaller form factor
25% smaller vs. Gen8 Common Slot
Provides more usable space inside the server
Efficiency
Starting point at 94% - 80Plus Platinum-certified
Upgrade to Titanium (96%) certified option (available
1H2015)
Compatibility
Available on ProLiant Gen9 Performance Series only
Not backward compatible with previous generation
servers

147
Copyright 2014 Hewlett-Packard Development Company, L.P. The information contained herein is subject to change without notice. Authorised HP Channel
Partners Only
Evolution of HP ProLiant Power
Solutions 50W per cubic inch

40W per cubic inch


96%
Power 30W per cubic inch
Density 94%

92%

89%
Power

Gen9
Gen9
Efficiency

Gen
Gen 8
Gen
Gen 7
Gen
Gen 6

Transition to Transition to
common power Flex Slot
7
supply form supply form
factor factor

148
Copyright 2014 Hewlett-Packard Development Company, L.P. The information contained herein is subject to change without notice. Authorised HP Channel
Partners Only
ProLiant Gen8 (E-Series) vs. Gen9 (10 and 100
Series)
Feature/Function Gen8 Gen9
Form Factor ATX & Common Slot 1U ATX & RPS (Dual PFC)
ATX - 550W
ATX - 350W, 460W Upgrade to 900W RPS (rip and
Output Options
Common Slot 460/750/1200W replace 550W ATX, December
2014)
AC Input Voltages 100-240V 100-240V
DC Input Voltages 48VDC Upgrade to P-Series
Gold/Platinum (Common Slot)
Efficiency 80+ (80% - 90%); RPS 94%
80+ (ATX)
Intelligent Power Discovery On all Platinum Plus options Upgrade to P-Series
ATX standard option 1U ATX standard option
Compatibility
Upgrade to Common Slot Upgrade to RPS

149
Copyright 2014 Hewlett-Packard Development Company, L.P. The information contained herein is subject to change without notice. Authorised HP Channel
Partners Only
ProLiant Gen8 (P-Series) vs. Gen9 (300 Series)

Feature/Function Gen8 Gen9


Form Factor Common Slot Flex Slot
Output Options 460W, 750W, 1200W, 1500W 500W, 800W, 1400W

AC Input Voltages 100-240V, 277V 100-240V, 277V

DC Input Voltages 48VDC, 240-380V 48VDC, 240-380V

Efficiency Gold/Platinum/Titanium Platinum/Titanium

Intelligent Power Discovery On all Platinum/Titanium options On select Platinum/Titanium


Support options
Compatibility All P-Series servers All Gen9 300 Series

150
Copyright 2014 Hewlett-Packard Development Company, L.P. The information contained herein is subject to change without notice. Authorised HP Channel
Partners Only
HP ProLiant Gen9 Power strategy

300-Series Performance Servers


Focus on power density, efficiency, and flexibility
New Flex Slot form factor (25% smaller)
80+ Platinum-certified (94%)
500W, 800W, 1400W output options

100-Series Essential Servers


Focus on value optimization, balancing features and
price
1U ATX power supply form factor with 550W output
Non-redundant with 80+ Silver certification (89%)

151
Copyright 2014 Hewlett-Packard Development Company, L.P. The information contained herein is subject to change without notice. Authorised HP Channel
Partners Only
300-series: New Flex Slot Form Factor
Traditional design, but smaller form factor
25% smaller vs. Common Slot
Provides more usable space inside the server
Efficiency
80+ Platinum-certified (94%)
DC Efficienc
Wattage AC Volts IPD
Volts y
500W 100-240V 240VDC 94% No
800W 100-240V 240VDC 94% No
1400W 200-240V 240VDC 94% Yes
Note: 240VDC (China only)

Compatibility
Available on DL360, DL380, and ML350
Not backward compatible with previous server generations

152
Copyright 2014 Hewlett-Packard Development Company, L.P. The information contained herein is subject to change without notice. Authorised HP Channel
Partners Only
100-series: New Entry-Level Power
Supply
1U ATX form factor
Non-redundant, 550W output
Efficiency
80+ Silver-certified (89%)

DC Efficienc
Wattage AC Volts IPD
Volts y
550W 100-240V 240VDC 89% No
Note: 240VDC (China only)
Compatibility
Available on DL160 and DL180
Not backward compatible with previous server generations

153
Copyright 2014 Hewlett-Packard Development Company, L.P. The information contained herein is subject to change without notice. Authorised HP Channel
Partners Only
HP Power Supplies Features/Benefits
High efficiency power options that allow customers to reduce power
consumption and waste without impacting IT performance

Simplicity Efficiency Reliability Agility


Simplified Platinum Support for HP Flexible
spares certified Power Slot Power
strategy 94% Discovery Supply1
reduces data efficient Services design
center costs power improves provides
supply overall 25%
power reduction
managemen in size
t capabilities allowing for
additional
server
1
HP Flexible Slot Power Supplies are supported on the Gen9 options to be
Performance Servers added
Note: 1U ATX Non-RPS solution for Gen9 Essential Servers
Copyright 2014 Hewlett-Packard Development Company, L.P. The information contained herein is subject to change without notice. Authorised HP Channel
154

Partners Only
Available

ASHRAE A3/A4 support


Description Is What is Does What it Means Customer Associated Quants/Claims
the new, does function value statement,
unique benefit
differentiator
The ASHRAE HP ProLiant Gen9 ProLiant Gen9 Reduces Cost of HP ProLiant' s 40C Extended
guidelines for servers now servers can Service Ambient Support exceeds
data center support ASHRAE operate at higher More choices of air ASHRAE A3 relative humidity
operation suggest Class A3/A4 temperatures, cooled solutions standards by up to 10%
thermal ranges of thermal which would reduce Improve efficiency and Up to 20% lower data
operation for IT guidelines. cooling costs lower data center center power & cooling
equipment that Although not power and cooling cost costs with ASHRAE A3, A4
are commonly unique to HP, solutions
accepted by this level of
many data center certification is
administrators new in Gen9,
and facility meeting our
managers. competition.

ProLiant Gen9 However, HP


products support ProLiant' s 40C
A3 and A4 Extended
guidelines Ambient
Support
exceeds
ASHRAE A3
155
Copyright 2014 Hewlett-Packard Development Company, L.P. The information contained herein is subject to change without notice. Authorised HP Channel
relative
Partners Only
Elevated Temperature Support

35C has been the traditional maximum server inlet air temperature
For Gen9, 40C (ASHRAE A3) support available on most platforms with configuration
limitations
For Gen9, 45C (ASHRAE A4) support available in select platforms with configuration
limitations

156
Copyright 2014 Hewlett-Packard Development Company, L.P. The information contained herein is subject to change without notice. Authorised HP Channel
Partners Only
157
Copyright 2014 Hewlett-Packard Development Company, L.P. The information contained herein is subject to change without notice. Authorised HP Channel
http://
Partners Only
Elevated Temperature Support for
DL300 Series
HP server HP Standard ASHRAE
Operating A3
ASHRAE
A4
HP server HP Standard
Operating
ASHRAE A3
compatibility
ASHRAE A4
compatibility
Support compatibilit compatibilit Support
y y HP ProLiant DL380 Gen9
HP ProLiant DL360 Gen9 HP ProLiant Requirements: Options not Options not
HP ProLiant Requirements Requirements Requirements DL380 4LFF High supported: supported:
DL360 Gen9 : High : High : High HP ProLiant Performance Fan 160W 160W
LFF and SFF Performance Performance Performance DL380 8SFF Kit only for Workstation Workstation
Chassis Fan Kit for Fan Kit for all Fan Kit for all HP ProLiant Passive GPUs Processors Processors
note 8SFF 130W -160W configuration configuration DL380 16SFF LR DIMMs LR DIMMs
chassis same Processors s. s. GPUs GPUs
limitations as with LR Options not Options not 10Gb 533FLR- 10Gb 533FLR-
LFF with the DIMMs supported: supported: T FlexLOM T FlexLOM
addition of no 130W+ 130W+
rear HDD Processors Processors HP ProLiant High Not supported Not supported
support LR DIMMs LR DIMMs DL380 12LFF Performance Fan
GPU GPU Kit comes as a
10Gb 10Gb standard option
533FLR- T 533FLR- T in these chassis
FlexLOM FlexLOM

http://www.hp.com/go/proliant/ashrae
158
Copyright 2014 Hewlett-Packard Development Company, L.P. The information contained herein is subject to change without notice. Authorised HP Channel
Partners Only
Available

HP Uninterruptible Power Systems


(UPS)
Description Is What is
the new,
Does What it
does function
Means Customer
value statement,
Associated Quants/Claims

unique benefit
differentiator
Highly efficient HP Provide high Protect your computer Highest wattage per U
power protection Uninterruptable efficiency power equipment and critical space save valuable room in
for every Power Systems protection for all data against damage due the rack
environment. (UPS) provide up environments from to inconsistent and True sine wave output
to 19.9kVA of workstation to data fluctuating power protects valuable
power in a 5U center equipment
rack space one >97% efficiency prevents
of the highest- wasted power
density backup Enhanced Battery
power solutions Management (EBM) up to
available. 2x usable battery life
Hot swappable batteries
save time
3 year warranty standard,
even on the batteries
Pre-failure battery
notification prevents
outages

159
Copyright 2014 Hewlett-Packard Development Company, L.P. The information contained herein is subject to change without notice. Authorised HP Channel
Partners Only
Available

Location Discovery Services


Description Is What is Does What it Means Customer Associated Quants/Claims
the new, does function value statement,
unique benefit
differentiator
Solution that HP Intelligent Optimize Workload optimization Industry 1st location
merges the Series Racks workload Location with intelligence in servers and
physical rack with with the Location placement with workload, thermal and racks
IT equipment to Discovery option servers that self- power data provides
provide installed provide identify and data to place
automated detailed location inventory workloads
location information to Server learns Eliminate manual
awareness of ProLiant to track from rack the errors
installed servers new installations rack ID and Least expensive to
and equipment server U location build, install, and
moves. HP iLO collects operate/maintain no
and passes this active components, no
data on to power, no network,
Insight Control to not another item to
auto populate a manage in the data
server location center
screen

160
Copyright 2014 Hewlett-Packard Development Company, L.P. The information contained herein is subject to change without notice. Authorised HP Channel
Partners Only
Available

HP Rack Mount Power Distribution Units


(PDU)
Description Is What is the
new, unique
Does What it
does function
Means Customer
value statement,
Associated Quants/Claims

differentiator benefit
HP PDUs provide Multiple levels of Provides highly High accuracy Industry leading within 1%
power power accurate and monitoring prevents power monitoring accuracy
distribution and management are flexible power circuit overload errors at the inlet, load segment,
management available, from distribution and Multiple form factors and outlet
within IT racks; Basic to Intelligent; management that provide flexibility Industry leading 3 year
HP supports 4 Support for solutions for IT in mounting locations warranty
separate PDU multiple form racks to ease cable Automatic Care Pack
product lines factors including management coverage save hundreds of
with differing 0U/vertical and Power Discovery dollars on extended
levels of power modular (with Services (PDS) warranties
management support for prevents or eliminates
capabilities. core/stick); HP many of the errors
Power Discovery associated with
Services (PDS) configuring and
supported on the managing power
Intelligent (iPDU) within the data center
product line.

161
Copyright 2014 Hewlett-Packard Development Company, L.P. The information contained herein is subject to change without notice. Authorised HP Channel
Partners Only
Available

Power Discovery Services


Description Is What is Does What it Means Customer Associated Quants/Claims
the new, does function value statement,
unique benefit
differentiator
Power Discovery HP Power When you deploy Automatically Extend the life of your data
Services Discovery new HP ProLiant configure power center by reclaiming up to
combines HP Services is the servers and distribution to speed 3x energy capacity of
Intelligent Power first technology BladeSystem implementation and facilities
Distribution Unit to create an enclosures, HP prevent downtime Prevent 100% of common
(iPDU), HP automated, Power Discovery Capture accurate configuration errors
Platinum power energy-aware Services power data across Eliminate 25% of data
supplies and HP network between automatically racks and rows of center outages
Insight Control IT systems and discovers the new servers to identify and Industry leading within 1%
software to facilities. equipment, maps eliminate areas of power monitoring
automatically them to the power waste accuracy at the inlet, load
track new server This allows your source, verifies segment, and outlet
installation and company to power redundancy Reclaim up to 10% of
provide higher reclaim millions and makes sure stranded power
precision, control, of dollars in everything is Industry leading 3 year
and automation wasted power connected warranty
to power capacity and correctly. Automatic Care Pack
distribution. downtime costs coverage save hundreds on
across data extended warranties
centers.
162
Copyright 2014 Hewlett-Packard Development Company, L.P. The information contained herein is subject to change without notice. Authorised HP Channel
Partners Only
Po
A
D

st
HP Flex Slot 750W Battery Backup
N

La
u nc
(MicroUPS)

h
Description Is What is Does What it Means Customer Associated Quants/Claims
the new, does function value statement,
unique benefit
differentiator
Lithium-Ion based Unique solution Provides backup Eliminates the need to Up to 1 minute of runtime
battery backup in for integrates power for servers, allocate space in the with 750W of power
a Flexible Slot battery-based allowing for up to 1 rack to backup power Eliminate 100% of rack
power supply backup power minute of runtime (typically 6U to 10U of space dedicated to backup
form factor that directly into the in the event of rack space) power
provides up to server as power loss Less cabling Lower backup power costs by
750W of backup opposed to Lower cost backup 50% or more
power and up to providing backup power solution
1 minute of power at either
runtime for HP rack or room
Gen9 300 series level
ProLiant servers

163
Copyright 2014 Hewlett-Packard Development Company, L.P. The information contained herein is subject to change without notice. Authorised HP Channel
Partners Only
Services

Copyright 2014 Hewlett-Packard Development Company, L.P. The information contained herein is subject to change without notice.
Available

HP Technology Services
Description Is What is Does What it Means Customer Associated Quants/Claims
the new, does function value statement,
unique benefit
differentiator
Technology Foundation Provides IT advice Support portfolio is $112K/year potential savings
Consulting Care SKUs and consulting to a simplified and with proactive services when
and Support are greatly transform, deploy standardized products are connected to HP
services that simplified and integrate new portfolio of support Prevent issues before they
can be with no technology plus services across all impact business (up to 66%
purchased legacy flexible ongoing technologies, less downtime)
with new HP foundational support services offered uniformly in Analysis & planning for
servers. support SKUs for organizations all geographies. systems migration,
launched on and government HP remote support consolidation & virtualization
Our services ProLiant Gen9 agencies. technology allows Up to 50% reduction in service
help Products customers to get calls
organizations Proactive connected to HP Get up and running with
and Care for 24x7 coverage, trained workforce and
government Advanced proactive problem minimum risk and disruption
agencies new service, prevention, Deliver workloads and IT as
reduce risk, launched in accurate problem a service your way
realize agility May, diagnosis and Reduce deployment time with
and stability promoted faster problem factory integration & technical
as they blend on ProLiant resolution, as well consultantsOrder to
tomorrows Gen9 Blades as interactive operations in as few as 15 days
innovations for the first support portals and Near 100% diagnostic
Copyright 2014 Hewlett-Packard Development Company, L.P. The information contained herein is subject to change without notice. Authorised HP Channel
165
with todays time tools. accuracy
Partners Only
HP Technology Support Services
Personalized, proactive, simplified

Support for Converged IT Environment


Infrastructure support
Foundation Care Proactive Care Datacenter Care
Keep my converged Prevent issues and get Help me better operate
infrastructure running me to your best what I have today and
experts when there is evolve to Hybrid IT
an issue

Proactive Care
Advanced Dedicated
resources to help
Per Device Device or System/Solution
maximize performance Environment

166
Copyright 2014 Hewlett-Packard Development Company, L.P. The information contained herein is subject to change without notice. Authorised HP Channel
Partners Only
Your partner for the life of your
datacenter
Ensure the right Smooth
solution Advise & Integrat
e deployments
Transformation Experience
Workshops transform HP Migration Services
Platform Migration Strategy HP Implementation Services
Advisory Services HP Education Services
Workload Advisory Services

Gen9
Increase Flex Support Improve stability
agility
Flexible Capacity Proactive Care
Hybrid Support Foundation Care
Datacenter Care

HP Technology Services for HP ProLiant Gen9


167
Copyright 2014 Hewlett-Packard Development Company, L.P. The information contained herein is subject to change without notice. Authorised HP Channel
Partners Only
Get connected and get back to business
Tap into the knowledge of millions of devices and thousands of experts
Solve problems
Prevent Problems Stay informed and
faster
in control

Up to 66% less downtime* Near 100% 1 consolidated view


diagnostic
accuracy
* Based on using Proactive Care. IDC White Paper,
sponsored by HP and Intel, The Business Value of the
HP Proactive Insight Experience, doc #239199, (March
2013).
168
Copyright 2014 Hewlett-Packard Development Company, L.P. The information contained herein is subject to change without notice. Authorised HP Channel
Partners Only
New Foundation Care services for
ProLiant
Simplified servers
portfolio reduces complexity and streamlines support
Consistent support choices across HP
servers, software, storage and networking products
Call to repair Coverage window
4 hour, 24x7 HW 2 hour, 24x7 SW
choices
6 Hour call to repair support
choices support
6 Hour call to repair 2 hour,9x5 SW
HP Foundation 2 hour, 24x7 HW
HP Foundation Care
24 hour call to support support
Care
repair 4 hour, 13x5 HW 24x7 4 hour, 9x5 SW
Call to support support
call to repair + 4 hour, 9x5 HW
Repair Support Plus 24
support HP Foundation Care
Other CTR Next BusinessSupport
NBD hardware support Day Plus
Scheduled onsite
Foundation Care for ProLiant, Apollo and Moonshot includes
collaborative software support
Care Pack Services available for 3,4, or 5 years
169
Copyright 2014 Hewlett-Packard Development Company, L.P. The information contained herein is subject to change without notice. Authorised HP Channel
Partners Only
Available

HP Care Pack Services


Description Is What is the Does What it Means Customer Associated Quants/Claims
new, unique does function value statement,
differentiator benefit
HP Care Pack Provide proactive HP Care Pack Buying and (same as prior page)
Services are support to help Services provide renewing support Greatly simplified support
support prevent system hardware and easy and flexible. decisions reduced SKUs by
packages that downtime for software When you purchase more than 40%
expand and business critical IT. support, an HP product,
extend standard If failures do occur, installation from HP or from a
warranties for provide the level of services, reseller, it's easy to
HP hardware response needed to education find the right
and software. meet the needs of services and support to meet
the business, proactive SLAs and budget.
whenever and services to meet Find exactly the
wherever they the needs of level of support you
need it. business-critical need using
Greatly simplified IT environments. HP Care Pack Centr
Foundation Care al
hardware and
software support,
eases decision-
making
Collaborative
software support
now included as
Copyright 2014 Hewlett-Packard Development Company, L.P. The information contained herein is subject to change without notice. Authorised HP Channel
170
standard
Partners Only
Available

HP Proactive Care Services


Description Is What is the Does What it Means Customer Associated Quants/Claims
new, unique does function value statement,
differentiator benefit
HP Proactive New Proactive Prevents Reduce downtime Up to 66% less downtime
Care services Care Advanced problems by and prevent *with remote support
help prevent service for business using technology problems with technology and proactive
issues and solve critical IT adds local to predict proactive services services
problems faster. assigned account potential failures based on Up to 50% reduction* in
Our innovative manager to and firmware innovative remote time spent resolving service
remote support personalize the issues so they support technology call events by using remote
technology proactive advice can be resolved Solve problems support technology
enables you to and critical event without faster with near Customers saved up to
stay informed management to disrupting the 100% diagnostic $112K annually* in avoided
and in control. quickly address business accuracy and rapid operational costs by using HP
complex issues Provides access to advanced proactive services
Available for all personalized technical experts
Gen9 servers as information Ensures high
part of HP specific to your visibility to resolve
Technology needs device outages
* IDC White Paper, sponsored by HP and Intel,
Services support Brings the right quickly using The Business Value of the HP Proactive Insight
portfolio level of visibility enhanced critical Experience, doc #239199, (March 2013).
and technical incident
resources to management
address critical
issues
171
Copyright 2014 Hewlett-Packard Development Company, L.P. The information contained herein is subject to change without notice. Authorised HP Channel
Partners Only
HP Financial Services
supporting ProLiant
Gen9

Copyright 2014 Hewlett-Packard Development Company, L.P. The information contained herein is subject to change without notice.
HP technology refresh for compute
Proactive program provides greater flexibility to routinely upgrade
Server Technology
Easier to acquire Easier to manage and refresh
Structure payments to align with IT and financial Greater flexibility, predictability
goals Extend your term, upgrade and expand when you need to
Low monthly usage payments save 10% - 15%
over 3 or 4 years vs. a cash purchase Proactive lifecycle management
Reduce cash outlay, accelerate ROI and payback Transition planning starts 120 days before end of term
Bundle hardware, software and services into a single Returns are easy with our pack and ship services,
payment structure helping your staff be more productive
Be confident in secure data removal with our disk
Dual usage options facilitate easier transition wiping services
and migration Our customer portal gives you greater visibility to
Defer payments up to 90 days manage IT investments
Convert current servers to a monthly payment plan Rest assured that any equipment that we recycle for
Avoid disruption to your computing and budget you will be done in compliance with environmental
plans regulations

Pre-provisioning solution helps avoid tying up


capital
Acquire up to 12 months of planned server capacity
Financing and service offerings available through Hewlett-Packard Financial Services Company and its subsidiaries and affiliates (collectively HPFSC) in certain countries and is subject
upfront, pay as you deploy it
to credit approval and execution of standard HPFSC documentation. Rates and terms are based on customers credit rating, offering types, services and/or equipment type and options.
Not all customers may qualify. Not all services or offers are available in all countries. Other restrictions may apply. HPFSC reserves the right to change or cancel this program at any time
without notice.
173
Copyright 2014 Hewlett-Packard Development Company, L.P. The information contained herein is subject to change without notice. Authorised HP Channel
Partners Only
More than just IT asset removal
HP Asset Recovery Services Recycle

Advantages
Facilitates a technology refresh/upgrade
Helps reduce environmental and data privacy risks Re-market
Potential for cash return on your IT assets

Business needs Solution Benefits

Improved operational Lifecycle Services to manage Simplicity single reconciliation


efficiency the physical, contractual and process for IT assets, globally
Enhanced flexibility and financial aspect of IT assets Flexibility HP and non-HP
agility Global expertise in equipment
Help to reduce environmental and data Efficiency single, disciplined
environmental and data security requirements and best processes for managing IT assets
security risks practices
A trusted, expert advisor Global consistency in solutions
174
Copyright 2014 Hewlett-Packard Development Company, L.P.and
who can simplify IT asset servicecontained herein is subject to change without notice. Authorised HP Channel
The information
Partners Only
Other technologies
supporting ProLiant
Gen9 platforms

Copyright 2014 Hewlett-Packard Development Company, L.P. The information contained herein is subject to change without notice.
Available

HP SmartDrive
Description Is What is the Does What it does Means Associated
new, unique function Customer value Quants/Claims
differentiator statement,
benefit
Hot plug drive Introduced in Enhanced display of Standard across 2.5-inch small form factor
carriers aligned ProLiant Gen8 and self-describing icons ProLiant (SFF) and 3.5-inch large
with HP Gen9 continued on with intuitive and platforms form factor (LFF) hot-plug
Smart Storage ProLiant Gen9 improved LED More reliability carriers
solutions platforms, HP function Optimized for
enable a SmartDrive Animated drive ProLiant servers
balanced technology activity spinner
system includes HP-only Do not remove
architecture design features like indicator reduces
a Do Not Remove logical drive failures
LED that prevents due to accidental
data loss and removal of a drive
reduces downtime. Smart carrier
authentication to
verify that both drive
and carrier are HP-
qualified options
Drive error log NVRAM
with black-box
recorder, for better
failure analysis and
Copyright 2014 Hewlett-Packard Development Company, L.P. The information contained herein is subject to change without notice. Authorised HP Channel
176
resolution
Partners Only
Available

HP Smart Socket guide


Description Is What is the Does What it Means Customer Associated Quants/Claims
new, unique does function value statement,
differentiator benefit
HP Smart Socket Continuation of Gen8 Provides quick, The HP Smart Socket N/A
guide is an technology to Gen9 precise, intelligent guide confidently
assembly that processor allows for quick and
allows you to installation. easy field upgrade of
confidently add processors without
or upgrade the fear of damaging
processors the processor pins
without the fear that could potentially
of bending pins lead to motherboard
that failure.
leads to
motherboard
failure and
replacement.

177
Copyright 2014 Hewlett-Packard Development Company, L.P. The information contained herein is subject to change without notice. Authorised HP Channel
Partners Only
Available
HP Smart Socket Guide
Solving an industry issue with HP innovation

Addresses bent CPU socket pin issue Eliminates 80% of failures


which is the leading cause of system caused by improper installation
board failure in the IT industry of processors
Open ILM and Install
Cove remove cover Processor Close ILM
r

178
Copyright 2014 Hewlett-Packard Development Company, L.P. The information contained herein is subject to change without notice. Authorised HP Channel
Partners Only
Available

Simpler Serviceability
Description Is What is the Does What it Means Customer Associated Quants/Claims
new, unique does function value statement,
differentiator benefit
HP ProLiant Most of the
Gen9 Servers serviceable
continue the components
simple require no tools to
serviceability access
characteristics
introduced in
the ProLiant
Gen8 servers.

179
Copyright 2014 Hewlett-Packard Development Company, L.P. The information contained herein is subject to change without notice. Authorised HP Channel
Partners Only
Available

Simpler serviceability
Tool-less access everywhere greatly reducing time to service

Tool-less access to all


serviceable components
Clear, intuitive labeling
Enhanced graphics and color that clearly
illustrate the step by step instructions for
configuring and servicing the server
Help you find and fix components faster
Clear baffles
Clear see through baffles allowing visibility
to see which processors and memory slots
are populated
Clean and elegant cabling
Flat thin cables route along the sides of the
system and are secured in place with
guides and locking cable guards
180
Copyright 2014 Hewlett-Packard Development Company, L.P. The information contained herein is subject to change without notice. Authorised HP Channel
Partners Only
A closer look at the
ProLiant Gen9 servers
available at launch

Copyright 2014 Hewlett-Packard Development Company, L.P. The information contained herein is subject to change without notice.
HP ProLiant Gen9 Series Available today

HP ProLiantDL160 HP ProLiantDL180 HP ProLiant DL360 HP ProLiant DL380


Gen9 Gen9 Gen9 Gen9
Right sized The new standard for Dense performance for THE no-compromise
performance for growing datacenter multi-workload data center standard
space and budget needs computes in the data for multi-workload
constrained center compute
environments

HP ProLiantML350 HP ProLiant BL460c HP ProLiant XL230a HP ProLiant XL730f


Gen9 Gen9 Server Server
Efficient, high- The worlds leading Apollo 6000 System Apollo 8000 System
performance server server blade, server, density optimized server for high
delivers expandability, performance optimized performance for scale-out performance
manageability and for core IT workloads workloads computing workloads
reliability
182
Copyright 2014 Hewlett-Packard Development Company, L.P. The information contained herein is subject to change without notice. Authorised HP Channel
Partners Only
HP ProLiant DL160 Gen9 Server
Right sized performance and storage density for space and budget constrained
environments
Introducing
Versatile Optimized design, Agile Infrastructure
combination of efficiency and management for
performance and scalability for essential
density Hyperscale administration
Environments

The HP ProLiant DL160 Gen9 Server delivers the right balance of performance, storage,
reliability, manageability and efficiency in a new dense and compact chassis, to meet the
needs of a diverse set of customers and a wide range of workloads - from general purpose IT
to the New Style of IT.

183
Copyright 2014 Hewlett-Packard Development Company, L.P. The information contained herein is subject to change without notice. Authorised HP Channel
Partners Only
For sales & channel

HP ProLiant DL160 Gen9 only

Right sized performance and storage density for space and budget constrained
hp.com/servers/dl160Gen9
environments
Key selling points Ideal for Price
Up to 2 Intel Xeon E5-2600
Essential Combination of Mid level virtualization, positioning
Standard 3-1-1 v3 Series, 4/6/8/10/12 Cores
Performance, IT/ web infrastructure for US ILP* Entry SATA
manageability and SMBs, small enterprises starting@ $1,719 to Base (16) DDR4, (512GB max)
Storage for the IT needs Distributed computing: $2,569 Up to 8 SFF/4 LFF max,
of SMBs compute Breakthrough
nodes, NoSQL
efficiency and scale HDD/SSD
Scalability and Efficiency apps
in a dense design for SALES PLAY : Just Right Standard HP Dynamic Smart
Hyperscale Environments IT Array B140i
Agile Infrastructure Embedded 2 x1GbE,
Management for FLexibleLOM1
Accelerating IT Service
Delivery 3 PCIe 3.0 slots
Key competitive advantages
HP iLO 4 v2.0, UEFI and legacy
Advanced features expanded over Gen8 boot mode
UEFI, higher ambient temp support and
flexibility to offer a lower price up to 94% Efficiency
HP OneView11 for improved manageability (Platinum), 550W multi-
in large environment output, 900W RPS3
Built-in iLO 4 to simplify IT infrastructure
Standard 3-1-1 warranty
mgmt. for customers/partners at 0
incremental cost TPMtext
Blue option
designates new or
FLexibleLOM22 support for networking improved feature over a
flexibility and up to three PCIe slots for IO Replaces
previous DL360eproduct
generation Gen8/ DL160
184
expandability
Copyright 2014 Hewlett-Packard Development Company, L.P. The information Gen8
contained herein is subject to change without notice. Authorised HP Channel
1
HPPartners
OneView support for ProLiant Gen9 in DL and BL servers expected later in 2014. 2Flexible LOM will be supported in Nov 2014 394% 900W*RPS
Only US ILP and subject to change without notice
HP ProLiant DL160 Gen9 to DL360e
Gen8
Right sized compare
performance and storage density for space and budget
constrained environments
ProLiant DL160 Gen9 ProLiant DL360e Gen8
Blue text
designates
new or
Up to 2 Intel Xeon E5-2400/ 2400 v2 Series, 4/6/8/10 improved
Up to 2 Intel Xeon E5-2600 v3 Series, 4/6/8/10/12 Cores
Compute Cores feature
PCIe 3.0, up to 3 available slot(s)
PCIe 3.0, up to 2 available slot(s) over a
Memory HP Smart Memory (16) DDR4, up to 2133MHz (512GB max), HP Smart Memory (12) DDR3, up to 1600MHz (384GB max) previous
Storage Standard HP Dynamic Smart Array B140i HP Dynamic Smart Array B120i generation
FBWC NA NA product

Battery NA NA
HP SmartDrives 8 SFF / 4 LFF max, HDD/SSD 8 SFF / 4 LFF max, HDD/SSD
Networking Embedded 2 x1GbE with optional FlexibleLOM on riser 1GbE NC366i 4ports
VGA/Serial/USB Ports 1 rear video, up to 4 USB 3.0, 1 USB2.0 1 front/ 1 rear video port, 1 serial, 7 USB 2.0
GPU Support NA Supported
Management
On Premise HP OneView and HP iLO Advanced HP OneView and HP Insight Control
On Cloud HP Insight Online with enhanced mobile appl HP Insight Online
On System HP iLO 4, HP SUM, HP RESTful Interface Tool, UEFI HP iLO 4, HP SUM
Power & Cooling up to 94% eff. (Platinum), 550W multi-output, 900W1 RPS up to 96% Efficiency (Titanium), Common Slot FF
Industry Compliance ASHRAE A3 & A4, lower idle power NA
Power Discovery Services NA Supported
Location Discovery
NA Supported
Services
Chassis Depth 23.9 (SFF), 23.9 (LFF) 27.5 (SFF), 29.5 (LFF)

Serviceability
1
94% 900W RPS will be available in Nov 2014
185Easy Install Rails Standard Standard
Copyright 2014 Hewlett-Packard Development Company, L.P. The information contained herein is subject to change without notice. Authorised HP Channel
Warranty 3/1/1 3/1/1
Partners Only
HP ProLiant DL180 Gen9 Server
The new standard for growing datacenter needs
Introducing
Performance & High Availability Agile Infrastructure
scalability to meet and Efficiency for management for
growing data needs dense storage essential
applications administration

The HP ProLiant DL180 Gen9 Server delivers an optimized 2U server, designed with the
right balance of expandability, performance, reliability and manageability all in a new compact
chassis, making it the ideal platform for SMBs and Enterprises running the New Style of IT.

186
Copyright 2014 Hewlett-Packard Development Company, L.P. The information contained herein is subject to change without notice. Authorised HP Channel
Partners Only
For sales & channel

HP ProLiant DL180 Gen9 only

The new standard for growing datacenter needs


hp.com/servers/dl180Gen9
Key selling points Ideal for Price
Up to 2 Intel Xeon E5-2600
Scalability and General purpose positioning
US ILP* for Entry 4LFF v3 Series, 4/6/8/10/12 Cores
Performance to Meet the requirements for SMB and NHP starting @ $ 1,829
(16) DDR4, (512 GB max)
New Standard of Growing Budget conscious to Base $ 2,459.
Data Center Needs enterprises Standard 3-1-1 Warranty 16 SFF / 12 LFF max, HDD/SSD
High Availability and Dense Breakthrough
storage at optimal Optimal performance and
efficiency and scale Std. HP Dynamic Smart Array
Efficiency for Dense performance for Web affordability offering
Storage Applications Infrastructure and Service flexible configurations B140i
Agile Infrastructure Providers and scalable options to Embedded 2 x1GbE with
Management for Scalability & expandability meet varied customer optional Flexible LOM on riser
Accelerating IT Service for cloud and virtualization requirements
Delivery requirements 6 PCIe 3.0 slots (3 + 3 FH/HL)
Key competitive advantages HP iLO 4 v2.0, UEFI and legacy
Leading storage capacity and wide variety boot mode
of options to choose from. Up to 94%2 Efficiency, 1U ATX
Supports up to 6 PCIe slots FF
Support for GPU up to one single wide
Active card11 Standard 3-1-1 warranty
Shorter chassis depth TPM option
Replaces DL380e Gen8
Blue text designates new or
improved feature over a
previous generation product
Copyright 2014 Hewlett-Packard Development Company, L.P. The information contained herein is subject to change without notice. Authorised HP Channel
187
Features will be supported in Nov 2014 294% 900W RPS will be available in Nov 2014
1 *US ILP and subject to change without notice
Partners Only
HP ProLiant DL180 Gen9 to DL380e
Gen8
The compare
new standard for growing datacenter needs
Blue text
ProLiant DL180 Gen9 ProLiant DL380e Gen8 designate
Up to 2 Intel Xeon E5-2400/2400 v2, 2/4/6/8/10 s new or
Up to 2 Intel Xeon E5-2600 v3 Series, 4/6/8/10/12 Cores
Compute Cores improved
PCIe 3.0, up to 6 available slot(s)
PCIe 3.0, up to 6 available slot(s) feature
HP Smart Memory (12) DDR3, up to 1600MHz (384GB over a
Memory HP Smart Memory (16) DDR4, up to 2133MHz (512GB max)
max) previous
Storage Standard HP Dynamic Smart Array B140i HP Smart Array B120i generatio
FBWC N/A N/A n product
HP DL/ML/SL 96W Smart Storage Battery to support the
Battery N/A
standup controllers
HP SmartDrives 16 SFF / 12 LFF max, HDD/SSD 27SFF* / 14LFF* max - HDD/SSD
Networking Embedded 2 x1GbE with optional Flexible LOM on riser* 4x1GbE
VGA/Serial/USB Ports/SD Rear VGA or Serial, 4 USB 3.0, 1 USB 2.0, 1 Micro SD 1Serial, 7 USB 2.0
GPU Support Single/Double-Wide Active only* Single-Wide (1)
Management
On Premise HP OneView and HP iLO Advanced HP OneView and HP Insight Control
On Cloud HP Insight Online with enhanced mobile appl HP Insight Online
On System HP iLO 4, HP SUM, HP RESTful Interface Tool, UEFI HP iLO 4, HP SUM
Power & Cooling up to 94% eff. (Platinum), 550W multi-output, 900W RPS* up to 96% Efficiency (Titanium), Common Slot FF
Industry Compliance ASHRAE A3 & A4, lower idle power NA
Power Discovery Services NA Supported
Location Discovery
Optional Standard
Services
Chassis Depth 23.9 (SFF), 23.9 (LFF) 27.5 (SFF), 29.5 (LFF)
* Features will be available in Nov 2014
Copyright 2014 Hewlett-Packard Development Company, L.P. The information contained herein is subject to change without notice. Authorised HP Channel
188
Serviceability
Partners Only
HP ProLiant DL360 Gen9 Server
Dense performance for multi-workload computes in the datacenter
Introducing
Dense and flexible Industry leading Agile Infrastructure
high performance energy efficiency management for
compute for quicker returns accelerating IT
on your investment service delivery
and industry
recognized
benchmarks.

HPs leading server for dense general-purpose computing, the HP ProLiant DL360 Gen9
Server delivers increased performance with the best memory and I/O expandability packed in
a 1U dense rack design. Reliability, serviceability and always on availability, backed by a
comprehensive warranty, make it ideal for the most space constrained server workloads.

189
Copyright 2014 Hewlett-Packard Development Company, L.P. The information contained herein is subject to change without notice. Authorised HP Channel
Partners Only
For sales & channel

HP ProLiant DL360 Gen9 only

Dense performance for multi-workload computes in the data center


Key Selling Points Ideal for Price hp.com/servers/dl360Gen9
Dense and flexible high Dynamic workloads in Positioning
Standard 3-3-3. Up to 2 Intel Xeon E5-2600 v3
performance compute dense virtualized US ILP* Entry SATA Series, 4/6/8/10/12/14 Cores
Industry leading energy environments
Breakthrough (B140i) @ $ 2,799 to high (24) DDR4, (768GB max)
efficiency, for a quicker Compute intensive
efficiency and scale Performance SAS Up to 8+2 SFF/4 LFF max,
return on your applications (P440ar/2GB) @ $ 7,659 HDD/SSD
investment & industry Low latency and Std. HP Dynamic Smart Array
recognized benchmarks. transactional applications B140i
Agile Infrastructure SALES PLAY : Just Right Choice of HP Flexible Smart Array
management for IT or
accelerating IT service HP Smart HBA Controllers for
performance or additional
delivery
features
Key Competitive Advantages Choice of 4x1GbE embedded +
FlexibleLOM
HP Quality 3 PCIe 3.0 slots (UP to 1 FH/FL and
HP Smart Array 2 LP or 2 FH/FL)
HP iLO HP iLO 4 v2.0, UEFI and legacy
HP OneView11 for improved manageability boot mode
in large environment up to 94% Efficiency (Platinum
Plus), smaller Flexible Slot FF
Standard 3-3-3 warranty
1
HP OneView support for ProLiant Gen9 in DL and BL servers expected later in2014. Blue text designates new or improved feature over a previous generation
* US ILP and subject to change without notice product HP Secure Encryption & TPM
Copyright 2014 Hewlett-Packard Development Company, L.P. The information contained herein is subject to change without notice. Authorised HP Channel
190
option
Partners Only Replaces DL360p Gen8
HP ProLiant DL360 Gen9 to DL360p
Gen8
Dense compare
performance for multi-workload computes in the data center
Blue text
ProLiant DL360 Gen9 ProLiant DL360p Gen8 designates
new or
Up to 2 Intel Xeon E5-2600 v3 Series, 4/6/8/10/12/14 /16 / Up to 2 Intel Xeon E5-2600/-2600 v2 Series, improved
Compute 18 Cores 2/4/6/8/10/12 Cores feature
PCIe 3.0, up to 3 available slot(s) PCIe 3.0, up to 2 available slot(s) over a
Memory HP Smart Memory (24) DDR4, up to 2133MHz (768GB max), HP Smart Memory (24) DDR3, up to 1866MHz (768GB max) previous
Standard HP Dynamic Smart Array B140i generation
Storage Choice of HP Flexible Smart Array or HP Smart HBA HP Smart Array P420i product
Controllers for performance or additional features
FBWC 2GB DDR3-1866 MHz, 72-bit wide bus at 14.9 GB/s on P440ar 2GB DDR3-1333 MHz, 72-bit wide bus at 10.6 GB/s
Battery HP DL/ML/SL 96W Smart Storage Battery Super-cap
HP SmartDrives 8 +2SFF / 4 LFF max, HDD/SSD, Optional 2 SFF 10 SFF / 4 LFF max, HDD/SSD
Networking Choice of 4x1GbE embedded + FlexibleLOM Choice of 4x1GbE or 2x10GbE FlexibleLOM
VGA/Serial/USB Ports Front VGA Opt, Rear VGA Std. & Serial Opt., 4 USB 3.0 0 VGA , 1 Serial, 7 USB 2.0
GPU Support 2 Single-Wide and Active to 9.5 NA
Management
On Premise HP OneView and HP iLO Advanced HP OneView and HP Insight Control
On Cloud HP Insight Online with enhanced mobile appl HP Insight Online
On System HP iLO 4, HP SUM, HP RESTful Interface Tool, UEFI HP iLO, HP SUM
Power & Cooling up to 94% eff. (Platinum Plus) w/ Flexible Slot FF up to 96% Efficiency (Titanium), Common Slot FF
Industry Compliance ASHRAE A3 & A4, lower idle power ASHRAE A2
Power Discovery Services Supported Supported
Location Discovery
Optional Standard
Services
Chassis Depth 27.5 (SFF), 29.5 (LFF) 27.5 (SFF), 29.5 (LFF)

Serviceability
191
Copyright 2014 Hewlett-Packard Development Company, L.P. The information contained herein is subject to change without notice. Authorised HP Channel
Partners
Easy Only
Install Rails Standard Optional
HP ProLiant DL380 Gen9 Server
THE no-compromise datacenter standard for multi-workload compute
Introducing
"Future proof" Industry leading Agile Infrastructure
design keeps up energy efficiency management for
with your business for quicker returns accelerating IT
needs on your investment service delivery
and industry
recognized
benchmarks.

The datacenter standard for general-purpose compute, the HP ProLiant DL380 Gen9 Server
delivers the best performance and expandability in the HP 2P rack portfolio. Reliability,
serviceability and always on availability, backed by a comprehensive warranty, make it ideal
for any environment.

192
Copyright 2014 Hewlett-Packard Development Company, L.P. The information contained herein is subject to change without notice. Authorised HP Channel
Partners Only
For sales & channel

HP ProLiant DL380 Gen9 only

THE no-compromise data center standard for multi-workload compute


hp.com/servers/dl380Gen9
Key selling points Ideal for Price
Up to 2 Intel Xeon E5-2600
"Future proof" design Enterprise customers with positioning
Standard 3-3-3 v3 Series,
keeps up with your Workloads / Apps : US ILP* - Entry SATA 4/6/8/10/12/14/16/18 Cores
business needs Virtualization, Big data, starting @ $2,819 to (24) DDR4, (768GB max)
Industry leading energy Storage centric Apps, Data Performance $8,649
efficiency, for a quicker Breakthrough
Warehousing/analytics, Up to 24+2 SFF/12+3 LFF
efficiency and scale max, HDD/SSD
return on your CRM, ERP, VDI, SAP etc.
investment & industry SALES PLAY :
Std. HP Dynamic Smart Array
recognized benchmarks. Virtualization, Productivity B140i
Agile Infrastructure workhorse with the ability Choice of HP Flexible Smart
management for to adapt to any Array or HP Smart HBA
accelerating IT service environment even down to Controllers for performance or
delivery Remote Office/Branch additional features
Office
4x1GbE embedded + Choice of
Key competitive advantages FlexibleLOM + Standup
Embedded NIC + FlexibleLOM
6 PCIe 3.0 slots (FH/FL)
Embedded management stack
Flexible options, like HP Universal Media HP iLO 4 v2.0, UEFI and legacy
Bay boot mode
Performance gains with 12Gb HP Smart
Array and HP Smart Memory DDR4 up to 94% Efficiency (Platinum
Plus), smaller Flexible Slot FF
Standard 3-3-3 warranty
193
Copyright 2014 Hewlett-Packard Development Company, L.P. The information contained herein is subject to change without notice. Authorised HP Channel
Blue text designates new or improved
Partners Only *US ILP and subject to change without notice HP Secure
feature Encryption
over a & TPM
previous generation
HP ProLiant DL380 Gen9 to DL380p
Gen8
THE compare
no-compromise data center standard for multi-workload compute
Blue text
ProLiant DL380 Gen9 ProLiant DL380p Gen8 designate
Up to 2 Intel Xeon E5-2600 v3 Series, 4/6/8/10/12/14/16/18 Up to 2 Intel Xeon E5-2600/-2600 v2 Series, s new or
Compute Cores 2/4/6/8/10/12 Cores improved
PCIe 3.0, up to 6 available slot(s) PCIe 3.0, up to 6 available slot(s) feature
HP Smart Memory (24) DDR3, up to 1866MHz (768GB over a
Memory HP Smart Memory (24) DDR4, up to 2133MHz (768GB max)
max)
previous
Standard HP Dynamic Smart Array B140i
Choice of HP Flexible Smart Array or generatio
Storage Standard HP Smart Array P420i n product
HP Smart HBA Controllers for performance or additional
features
FBWC 2GB DDR3-1866 MHz, 72-bit wide bus at 14.9 GB/s on P440ar 2GB DDR3-1600 MHz, 72-bit wide bus at 10.6 GB/s
Battery HP DL/ML/SL 96W Smart Storage Battery Super-cap
HP SmartDrives 24+2 SFF / 12+3 LFF max, HDD/SSD 25 SFF / 12 LFF max, HDD/SSD
Networking 4x1GbE embedded + Choice of FlexibleLOM + Standup FlexibleLOM 4x1GbE or 2x10GbE + Standup
VGA/Serial/USB Ports/SD Front VGA Opt, Rear VGA & Serial Std, 6 USB 3.0, 1, Micro SD Rear VGA, 1 Serial, 7 USB 2.0, 1 Micro-SD
GPU Support Single/Double-Wide & Active/Passive up to 10.5 (3) Single Wide/Double graphic cards (2)
Management
On Premise HP OneView and HP iLO Advanced HP OneView and HP Insight Control
On Cloud HP Insight Online with enhanced mobile appl HP Insight Online
On System HP iLO 4, HP SUM, HP RESTful Interface Tool, UEFI HP iLO 4, HP SUM
Power & Cooling up to 94% eff. (Platinum Plus) w/ Flexible Slot FF up to 96% eff. (Titanium), Common Slot FF
Industry Compliance ASHRAE A3 & A4, lower idle power, Energy Star Energy Star
Power Discovery Services Supported Supported
Location Discovery
Optional Optional
Services
Chassis Depth 26.75 (SFF), 28.75 (LFF) 27.5 (SFF), 29.5 (LFF)

Serviceability
194
Copyright 2014 Hewlett-Packard Development Company, L.P. The information contained herein is subject to change without notice. Authorised HP Channel
Partners
Easy Only
Install Rails Standard Optional
HP ProLiant ML350 Gen9 Server
THE no-compromise datacenter standard for multi-workload compute
Introducing
Performance with Availability, Agile Infrastructure
unmatched expandability and management for
capacity and serviceability a essential
reliability winning administration
combination

The HP ProLiant ML350 Gen9 Server delivers a class-leading combination of performance,


availability, expandability, manageability, reliability and serviceability making it the choice for
remote offices, growing businesses and data centers.

195
Copyright 2014 Hewlett-Packard Development Company, L.P. The information contained herein is subject to change without notice. Authorised HP Channel
Partners Only
For sales & channel
HP ProLiant ML350 Gen9 only

Efficient, high-performance server delivers expandability, manageability


and
Key reliability
selling points Ideal for Price hp.com/servers/ml350Gen9
Performance with SMBs, remote offices of positioning
Standard 3-3-3 Up to 2 Intel Xeon E5-2600 v3
larger businesses or data US ILP* starting @ $ Series, 4/6/8/10/12/14/16/18 Cores
unmatched capacity and
reliability centers Workloads / Apps : 2,109 to E-Star $ 6,339 (24) DDR4, (768GB max)
CRM/ERP, Demanding
Availability, Breakthrough
workloads where storage Up to 48 SFF/24 LFF max,
expandability and efficiency and scale
performance, CPU and RAM
HDD/SSD
serviceability a size are at a premium. Standard HP Dynamic Smart Array
winning combination Sales Play: B140i. Choice of HP Flexible
Smart Array or HP Smart HBA
Agile Infrastructure Just
Just Right
Right IT
IT Controllers for performance or
Management for Remote Office and Branch
additional features
Office
Office
Essential Administration
4x1GbE embedded + Standup

8 PCIe 3.0 slots, 1 PCIe 2.0 slot


Key competitive advantages (FH/FL)
Greater Expansion with 24 LFF/48 SFF HP iLO 4, HP SUM, HP RESTful
Greater I/O Expansion with 9 PCIe / 8 USB interface tool, UEFI
ports up to 94 Efficiency (Platinum Plus)
Embedded 4 ports NIC Flexible Slot
Embedded management stack
Performance gains with 12Gb HP Smart Standard 3-3-3 warranty
Array and HP Smart Memory DDR4 Blue text designates new or
HP Secure
improved Encryption
feature over a & TPM option
previous generation product
196
Copyright 2014 Hewlett-Packard Development Company, L.P. The information contained herein is subject to change without notice.
ReplacesHP
Authorised ML350p Gen8 / ML350
Channel
G6
Partners Only *US ILP and subject to change without notice
HP ProLiant ML350 Gen9 to ML350p
Gen8 high-performance
Efficient, compare server delivers expandability, manageability
and reliability ProLiant ML350 Gen9 ProLiant ML350p Gen8 Blue text
designates
Up to 2 Intel Xeon E5-2600 v3 Series, 4/6/8/10/12/14 /16 /18 Up to 2 Intel Xeon E5-2600/-2600 v2 Series, new or
Compute Cores 2/4/6/8/10/12 Cores
improved
PCIe 3.0, up to 9 available slot(s) PCIe 3.0, up to 9 available slot(s)
feature
HP Smart Memory (24) DDR3, up to 1866MHz (768GB
Memory HP Smart Memory (24) DDR4, up to 2133MHz (768GB max), over a
max)
Standard HP Dynamic Smart Array B140i previous
Storage Choice of HP Flexible Smart Array or Smart HBA Controllers for Standard HP Smart Array P420i generation
performance or additional features product
FBWC 2GB DDR3-1866 MHz, 72-bit wide bus at 14.9 GB/s on P440ar 2GB DDR3-1600 MHz, 72-bit wide bus at 10.6 GB/s
Battery HP DL/ML/SL 96W Smart Storage Battery Super-cap
HP SmartDrives 48 SFF / 24 LFF max, HDD/SSD 24 SFF / 12 LFF max, HDD/SSD
Networking 4x1GbE embedded + Standup 4x1GbE embedded + Standup
VGA/Serial/USB Ports/SD Front VGA Opt, Rear VGA & Serial Std, 9 USB 3.0, 1 Micro SD 0 VGA, 1 Serial, 7 USB 2.0, 1 Micro-SD
GPU Support Single/Double-Wide & Active/Passive up to 10.5 (4) Single Wide/Double graphic cards (3)
Management
On Premise HP Insight Control and HP iLO Advanced HP Insight Control and HP iLO Advanced
On Cloud HP Insight Online with enhanced mobile appl HP Insight Online
On System HP iLO 4, HP SUM, HP RESTful interface tool, UEFI HP iLO 4, HP SUM
Power & Cooling up to 94% eff. (Platinum Plus) w/ Flexible Slot FF up to 96% eff. (Titanium), Common Slot FF
Industry Compliance ASHRAE A3 & A4, lower idle power, Energy Star Energy Star
Power Discovery Services Supported Supported
Location Discovery
Optional Optional
Services
Chassis Depth 28.5 (SFF), 28.5 (LFF) 27.5 (SFF), 27.5 (LFF)

Serviceability
197
Copyright 2014 Hewlett-Packard Development Company, L.P. The information contained herein is subject to change without notice.
Easy Install Rails Optional
Authorised
Optional
HP Channel
Partners Only
Warranty 3/3/3 3/3/3
For sales &

HP ProLiant BL460c Gen9 Blade Server


channel only

The worlds leading blade server


hp.com/servers/bl460c-Gen9
Key selling points Ideal for Price Up to 2 Intel Xeon E5-2600
Flexible embedded storage Enterprise customers with positioning
Standard 3-3-3
v3 Series, 4/6/8/10/12/14 /16 /
18 Cores
controller strategy for an Workloads / Apps : Not to Exceed Entry
ideal balance of Virtualization, IT and Web starting@ $3,619 to (16) DDR4, (512GB max),
performance & price infrastructure, Performance SKUs support for NVDIMM
Breakthrough
collaborative systems, and starting at $8,419
Up to 50% performance efficiency and scale 2 SFF max, HDD/SSD, 12Gb
increase with the new HPC
SAS support
Intel Xeon E5-2600 v3
processors SALES PLAY : Std. HP Dynamic Smart Array
Virtualization, Productivity B140i
Agile Infrastructure workhorse with the ability Choice of HP Smart HBA
management for essential to adapt to any blades H244br or
simplicity and automation environment HP Smart Array P244br for
performance or additional
Key competitive advantages features
HP Quality Choice of 2x10GbE, FlexFabric
Flexible embedded controller strategy 10Gb, FlexFabric 10/20Gb
20Gb Virtual Connect
Performance gains with 12Gb SAS and HP 2 PCIe 3.0 mezzanine slots
Smart Memory HP OneView, HP iLO, HP
HP OneView & Next generation iLO RESTful Interface Tool, UEFI
technologies
Future support for NVDIMMs, optional Standard 3-3-3 warranty
Blue text designates new or
redundant mSD, and M.2 improved feature over a
198 HP Secure
Copyright 2014 Hewlett-Packard Development Company, L.P. The information contained herein is subject to change without notice. Authorised
previous HP Encryption
product &
Channel
generation TPM
option
Partners Only
Blue text designates improved
feature between platforms

HP ProLiant DL Gen9 2S 1U Comparison


ProLiant DL360 Gen9 (Sep14) ProLiant DL160 Gen9 (Sep14)
Up to 2 Intel Xeon E5-2600 v3 Series,
Up to 2 Intel Xeon E5-2600 v3 Series, (12C)
Compute (18C)
PCIe 3.0, up to 3 available slot(s)
PCIe 3.0, up to 3 available slot(s)
HP Smart Memory (24) DDR4, up to 2133MHz HP Smart Memory (16) DDR4, up to 2133MHz
Memory
(768GB max) (384GB max)
Embedded HP Dynamic Smart Array B140i,
Embedded HP Dynamic Smart Array B140i,
Storage Choice of HP Flexible Smart Array or HP
optional HP Smart Array via PCI-e Standup Card
Smart HBA Controllers
HP SmartDrives 8+2 SFF / 4 LFF max, HDD/SSD 8SFF / 4 LFF / 4 LFF NHP max, HDD/SSD
4x1GbE embedded + Choice of FlexibleLOM 2 x 1Gb embedded NIC +Choice of
Networking
+ Standup FlexibleLOM1
VGA/Serial/USB Front VGA Opt, Rear VGA Std., Serial Opt, 1 rear video, 4 USB 3.0, 1 USB2.0, internal
Ports/SD 4 USB 3.0, internal Micro SD Micro SD
Up to 2 Single-Wide & Active/Passive up
GPU Support Not Supported
to 9.5 (2)

Management

HP iLO 4GB NAND includes: HP iLO 2GB NAND includes:


1GB Embedded User Partition 0GB Embedded User Partition
On System
Embedded iLO Physical Port Optional iLO Physical Port
768MB Active Health System tracking 512MB Active Health System tracking
Power & Cooling up to 96% eff. (Titanium) w/ Flexible Slot FF 550W multi output std, 2900W RPS (94% Eff.)
Industry
ASHRAE A3 & A4, lower idle power, Energy Star ASHRAE A3 & A4, Energy Star
Compliance
Power Discovery
Supported Not Supported
Services
Location Discovery
Optional Not Supported
Services
Chassis Depth 27.5 (SFF), 29.5 (LFF) 23.9 1
Flexible LOM will be supported in Nov 2014
199
Copyright 2014 Hewlett-Packard Development Company, L.P. The information contained herein is subject to change without notice. Authorised HP Channel
2
900W RPS will be supported in Nov 2014
Partners
Serviceability Only
Blue text designates improved
feature between platforms

HP ProLiant DL Gen9 2S 2U Comparison


ProLiant DL380 Gen9 (Sep14) ProLiant DL180 Gen9 (Sep14)
Up to 2 Intel Xeon E5-2600 v3 Series, (18C) Up to 2 Intel Xeon E5-2600 v3 Series, (10C)
Compute
PCIe 3.0, up to 3 available slot(s) PCIe 3.0, up to 2 available slot(s)
HP Smart Memory (24) DDR4, up to 2133MHz HP Smart Memory (16) DDR4, up to 2133MHz
Memory
(768GB max) (512 max)
Embedded HP Dynamic Smart Array B140i, Choice
Embedded HP Dynamic Smart Array B140i,
Storage of HP Flexible Smart Array or HP Smart HBA
optional HP Smart Array via PCI-e Standup Card
Controllers
HP SmartDrives 24+2 SFF / 12+3 LFF max, HDD/SSD Up to 16SFF / 12LFF max, HDD
4x1GbE embedded + Choice of FlexibleLOM + 2 x 1Gb embedded NIC +Choice of 1FlexibleLOM
Networking
Standup on riser +Standup
VGA/Serial/USB Rear VGA, Front VGA Opt, Rear Serial Opt, 6
Rear VGA, 4 USB 3.0, 1 USB2.0, 1-Micro SD
Ports/SD USB 3.0, 1-Micro SD
Up to 2 Single/Double-Wide & Active/Passive up
GPU Support Single-Wide Active only 1
to 10.5 (3)

Management 2

HP iLO 4GB NAND includes: HP iLO 2GB NAND includes:


1GB Embedded User Partition 0GB Embedded User Partition
On System
Embedded iLO Physical Port Optional iLO Physical Port
768MB Active Health System tracking 512MB Active Health System tracking
Power & Cooling up to 94% eff. (Platinum Plus) w/ Flexible Slot FF 550W multi output std, 1900W RPS (94% Eff.)
Industry
ASHRAE A3 & A4, lower idle power, Energy Star ASHRAE A3 & A4, Energy Star
Compliance
Power Discovery
Supported Not Supported
Services
Location Discovery
Optional Not Supported
Services
Chassis Depth 26.75 (SFF), 28.75 (LFF) 23.9 (SFF & LFF)
2
For full Management stack please see
Copyright 2014 Hewlett-Packard Development Company, L.P. The information contained herein is subject to change without notice. Authorised HP Channel
200
Serviceability backup

Partners Only
HP ProLiant ML350 Gen9 to ML350p
HPs best all-in-one server with expandability, serviceability and
Gen8
reliability
compare Blue text
ProLiant ML350 Gen9 ProLiant ML350p Gen8 designate
s new or
Up to 2 Intel Xeon E5-2600 v3 Series, Up to 2 Intel Xeon E5-2600/-2600 v2 improved
Compute (18C) Series, (12C) feature
PCIe 3.0, up to 9 available slot(s) PCIe 3.0, up to 9 available slot(s) over a
HP Smart Memory (24) DDR4, HP Smart Memory (24) DDR3, up to previous
Memory generatio
up to 2133MHz (768GB max) 1866MHz (768GB max)
Standard HP Dynamic Smart Array B140i n product
Choice of HP Flexible Smart Array or
Storage Standard HP Smart Array P420i
Smart HBA Controllers for performance or
additional features
HP SmartDrives 48 SFF / 24 LFF max, HDD/SSD 24 SFF / 18 LFF max, HDD/SSD
Networking 4x1GbE embedded + Standup 4x1GbE embedded + Standup
VGA/Serial/USB Front VGA Opt, Rear VGA & Serial Std, 6
VGA, 1 Serial, 7 USB 2.0, 1 Micro-SD
Ports/SD USB 3.0, 1 Micro SD
Single/Double-Wide & Active/Passive up to Single Wide/Double graphic cards
GPU Support
10.5 (4) (3)
Management
HP Insight Control and HP iLO
On Premise HP Insight Control and HP iLO Advanced
Advanced
HP Insight Online with enhanced mobile
On Cloud HP Insight Online
appl
HP iLO 4, HP SUM, HP RESTful interface
On System HP iLO 4 and HP SUM
tool, UEFI
up to 94% eff. (Platinum Plus) w/ Flexible
Power & Cooling up to 96% eff. (Titanium), Common Slot FF
Slot FF
Industry ASHRAE A3 & A4, lower idle power, Energy
Energy Star
Compliance Star
201 Power Discovery
Copyright 2014 Hewlett-Packard Development Company, L.P. The information contained herein
Supported is subject to change without notice.
Supported Authorised HP Channel
Services
Partners Only
Decision Flow

HELP for choosing the


right platform

Copyright 2014 Hewlett-Packard Development Company, L.P. The information contained herein is subject to change without notice.
Drive capability Rack Gen9 Platforms

203
Copyright 2014 Hewlett-Packard Development Company, L.P. The information contained herein is subject to change without notice. Authorised HP Channel
Partners Only
CPU / Memory capability Rack Gen9
Platforms

204
Copyright 2014 Hewlett-Packard Development Company, L.P. The information contained herein is subject to change without notice. Authorised HP Channel
Partners Only
Platform

Features Sets

Copyright 2014 Hewlett-Packard Development Company, L.P. The information contained herein is subject to change without notice.
DL380 Gen9
Value Prop: THE no compromise datacenter
standard

206
Copyright 2014 Hewlett-Packard Development Company, L.P. The information contained herein is subject to change without notice. Authorised HP Channel
Partners Only
HP ProLiant DL380 Gen9
Launch

Operating
System
Processor Up to (2) E5-2600 v3 up to 145W (P0) 160W (P1) (18C)
Power Supply 94%, FlexSlot PS
Single/Double-Wide & Active/Passive up to 10.5 (1/2)
GPU Support
NVIDIA Quadro, Tesla, Grid
Memory
24xDDR4 up to 2133 MHz, support for 8/16/32 GB
Subsystem
Storage Standard 10 ports of Intel SATA RAID (B140i) and AROC
Controller (x8 PCIe 3.0) for SAS + Smart Storage Battery
Networking 4x1GbE embedded + FlexibleLOM
Storage Embedded SATA (up to 10 ports), 12G SAS via optional
Controller AROC
SAS/SATA
LFF (SAS/ SATA): 4LFF, 12LFF + 3 LFF (rear) or 2SFF
Drives
(rear)
(12G SAS, 6G
SFF (SAS/ SATA): up to 24 SFF (8+8+8) + 2 SFF (rear)
SATA)
NVMe Support
(Non Volatile
Memory
Express)
Management iLO4 v2.0
207
Copyright 2014 Hewlett-Packard Development Company, L.P. The information contained herein is subject to change without notice. Authorised HP Channel
Value Add Only
Partners SMP, IP, SUM, SPP, STK, Restful API Tool, UEFI * Please see speaker notes
DL380 Gen9 optioned up example - 768900-B21
UID
SFF USB 3.0
Power
ILO Tab
SID
768884-B21 768857-B21 719067-B21
Option kit DS HP DL380 Gen9 HP DL380 Gen9
Ear 8SFF 8SFF
Bay2 Cage Bay1 Cage

UID
USB
724865-B21
3.0
HP DL380 Gen9
Power
Optical Media
724864-B21 HP DL380 Gen9 2SFF Kit ILO
Cage Kit
783008-B21 HP DL380 Gen9 2SFF Front SAS Cable Kit Tab

208
Copyright 2014 Hewlett-Packard Development Company, L.P. The information contained herein is subject to change without notice. Authorised HP Channel
Partners Only
Option: The 2SFF rear only supported in
the 24SFF/12LFF total build up chassis,

DL380 Gen9 SFF - Rear


HP DL380 Gen9 Serial Cable Kit
you do not loose your additional
expansion bay (I/O).

Option Kit PN: 768896-B21

2nd CPU Riser Options


1 CPU Riser Options
st
Option Kit Std. 3 Slot PN: 719073-B21 Bay: 2SFF drive cage kit
Option Kit GPU PN: 719079-B21
Option Kit GPU PN: 719082-B21 / Option Kit PN: 724864-
724865-B21 B21

COM
1st PCI Riser Secondary PCI 2SFF Drive Slot
FlexLOM Blank
Slot
3 Slot Riser Blank 2nd Power Supply Blank
719070-B21 Blank
209
Copyright 2014 Hewlett-Packard Development Company, L.P. The information contained herein is subject to change without notice. Authorised HP Channel
Partners Only
DL380 Gen9 optioned up example -
4LFF
Option kit
DS Ear

opening for cable


routing on DS Ear
Field upgrade
Left Ear Installation LFF
and SFF.
210
Copyright 2014 Hewlett-Packard Development Company, L.P. The information contained herein is subject to change without notice. Authorised HP Channel
Partners Only
DL380 Gen9 optioned up example -
12LFF
Option kit
DS Ear

Left Ear

211
Copyright 2014 Hewlett-Packard Development Company, L.P. The information contained herein is subject to change without notice. Authorised HP Channel
Partners Only
DL380 Gen9 Bay: 3LFF drive cage kit
Option Kit PN: 768856-B21
The 3LFF rear drives will be supported on the 12LFF chassis
only. Note you loose the additional PCI expansion and Serial
port with this configuration

3 LFF Drive Slot


Blank

212
Copyright 2014 Hewlett-Packard Development Company, L.P. The information contained herein is subject to change without notice. Authorised HP Channel
Partners Only
PCI Riser with Smart Array - Smart
Storage Battery power connector
GPU Power Connector

3x Smart Array Power Connector


213
Copyright 2014 Hewlett-Packard Development Company, L.P. The information contained herein is subject to change without notice. Authorised HP Channel
Partners Only
P440ar / B140i DL380 Gen9

B140i

P440ar
214
Copyright 2014 Hewlett-Packard Development Company, L.P. The information contained herein is subject to change without notice. Authorised HP Channel
Partners Only
DL380 Gen9 / 8-24SFF + 2SFF rear Capacity
#= bay standard 768857- standard 724864- 719067- 768857- standard
B21 B21 B21 B21

3 2 3 1 2 3

included All the cables required for specified server will be included All the cables required for specified server will be included
SSB* in the Expander kit in the Expander kit

2 x4 2 x4 9 x4 2 x4 9 x4
AROC AROC Exp AROC Exp
HP Smart Array HP Smart Array HP Smart Array HP Smart Array HP Smart Array
P440ar P440ar SAS P440ar SAS
SAS Daughter Card SAS Daughter Card Expander Card SAS Daughter Card Expander Card
726736-B21 726736-B21 727250-B21 726736-B21 727250-B21

215 * Smart
Copyright 2014 Hewlett-Packard Development Company, L.P. The information contained herein is subject to change without Storage
notice. Battery 96WHP
Authorised onlyChannel
needed once per
server
Partners Only
DL380 Gen9 / 8-24SFF Performance
#= bay standard 768857- standard 719067- 768857- standard
B21 B21 B21

3 2 3 1 2 3

Cable included Includes Mini Cable included Includes Mini Includes Mini Cable included
SAS SAS SAS
1x68p/2x36p 1x68p/2x36p 1x68p/2x36p
cable in 2nd bay cable in 1nd bay cable in 2nd bay
cage cage cage
SSB* 2 x4 2 x8 2 x4 2 x8 2 x4
AROC SA PCI AROC SA PCI AROC
HP Smart Array HP Smart Array
HP Smart Array HP Smart Array HP Smart Array
P840 P840
P440ar P440ar P440ar
SAS Card SAS Card
SAS Daughter Card SAS Daughter Card SAS Daughter Card
726736-B21 726897-B21 726736-B21 726897-B21 726736-B21

216 * Smart
Copyright 2014 Hewlett-Packard Development Company, L.P. The information contained herein is subject to change without Storage
notice. Battery 96WHP
Authorised onlyChannel
needed once per
server
Partners Only
High
DL380 Gen9 / 8-24SFF Performance
#= bay standard 768857- standard 719067- 768857- standard
B21 B21 B21

3 2 3 1 2 3

Includes Mini Includes Mini Includes Mini


Cable included SAS Cable included SAS SAS Cable included
1x68p/2x36p 1x68p/2x36p 1x68p/2x36p
cable in 2nd bay cable in 1nd bay cable in 2nd bay
cage cage cage
SSB* 2 x4 2 x8 2 x4 2 x8 2 x8 2 x4
AROC SA PCI AROC SA PCI SA PCI AROC
HP Smart Array HP Smart Array HP Smart Array HP Smart Array HP Smart Array HP Smart Array
P440ar P440 P440ar P440 P440 P440ar
SAS Daughter Card SAS Card SAS Daughter Card SAS Card SAS Card SAS Daughter Card
726736-B21 726821-B21 726736-B21 726821-B21 726821-B21 726736-B21

217 * Smart
Copyright 2014 Hewlett-Packard Development Company, L.P. The information contained herein is subject to change without Storage
notice. Battery 96WHP
Authorised onlyChannel
needed once per
server
Partners Only
DL380 Gen9 / 16+2 SFF front Performance
#= bay 724864- 768857- standard 724864- 768857- standard
B21 B21 B21 B21

2 3 2 3
Includes Mini Includes Mini
SAS SAS
1x68p/2x36p 1x68p/2x36p
cable in 2nd bay cable in 2nd bay
cage cage

Included in 2SFF 783009-B21 HP Included in 2SFF 783009-B21 HP


SSB* Cage DL380 Gen9 (SFF Cage DL380 Gen9 8SFF
SAS Cable Kit SAS Cable Kit
SATA only (1x68p/2x36p) SATA only
(1x68p/2x36p)

2 x4 2 x8 2 x4 2 x8
SA PCI AROC SA PCI
HP B140i HP Smart Array HP Smart Array HP Smart Array
SATA P840 P440ar P840
Controller SAS Card SAS Daughter Card SAS Card
726897-B21 726736-B21 726897-B21

218 * Smart
Copyright 2014 Hewlett-Packard Development Company, L.P. The information contained herein is subject to change without Storage
notice. Battery 96WHP
Authorised onlyChannel
needed once per
server
Partners Only
DL380 Gen9 | 4-LFF Model-X | SATA/SAS
ENTRY

config shows max 4 LFF drives

Empty no backplane
HP Smart Array 6GB SATA
B140i
Onboard Controller Cable included

HP Smart Array P440ar


12GB SAS Empty no backplane
or
HP H240ar Smart HBA
Cable included

SSB* for
P-controller
No Drive Cage upgrade possible

219 * Smart
Copyright 2014 Hewlett-Packard Development Company, L.P. The information contained herein is subject to change without Storage
notice. Battery 96WHP
Authorised onlyChannel
needed once per
server
Partners Only
DL380 Gen9 | 12-LFF Model-X | SATA/SAS
Capacity

config shows max 12 LFF / 12LFF+3LFF

HP 12Gb SAS
Expander Card

HP Smart Array P440ar

SSB* for
P-controller 727250-B21 HP 12Gb SAS Expander Card for DL380 Gen9
All the cables required for specified server will be included
in the kit

OR

3LFF rear drive cage 2SFF rear drive cage


loosing one I/O riser expansion

220 * Smart
Copyright 2014 Hewlett-Packard Development Company, L.P. The information contained herein is subject to change without Storage
notice. Battery 96WHP
Authorised onlyChannel
needed once per
server
Partners Only
DL380 Gen9 | 12-LFF Model-X | SATA/SAS
Performance

config shows max 12 LFF

1x 785991-B21 HP DL380 Gen9 12LFF SAS Cable


Kit
726897-B21 (1x Mini SAS 1x/68p to 2x/36p cable and 1x/68p to
SSB* for HP Smart Array 1x/36p )
P-controller B140i P840

221 * Smart
Copyright 2014 Hewlett-Packard Development Company, L.P. The information contained herein is subject to change without Storage
notice. Battery 96WHP
Authorised onlyChannel
needed once per
server
Partners Only
DL380 Gen9 | 12-LFF Model-X | SATA/SAS
Performance

config shows max 12 LFF / 12LFF+3LFF


726897-B21 1x 785991-B21 HP DL380 Gen9 12LFF SAS Cable
Kit
SSB* for HP Smart Array(1x Mini SAS 1x/68p to 2x/36p cable and 1x/68p to
P-controller B140i P840 1x/36p )

768856-B21 HP DL380 Gen9 3LFF Rear SAS/SATA Kit


Includes 1x Mini SAS 1x/68p to 2x/36p cable

OR

3LFF rear drive cage 2SFF rear drive cage


loosing one I/O riser expansion

222 * Smart
Copyright 2014 Hewlett-Packard Development Company, L.P. The information contained herein is subject to change without Storage
notice. Battery 96WHP
Authorised onlyChannel
needed once per
server
Partners Only
DL360 Gen9
Value Prop: Performance driven compute and
storage density

Copyright 2014 Hewlett-Packard Development Company, L.P. The information contained herein is subject to change without notice.
HP ProLiant DL360 Gen9
Launch

Operating System

Up to (2) Intel Xeon E5-2600 v3 up to


Processor
145W (P0) 160W (P1) (18C)
Power Supply 94%, Flexible Slot PS
GPU Support 2 Single-Wide and Active to 9.5
HP Smart Memory 24xDDR4 up to 2133 MHz,
Memory Subsystem
support for 8(SR)/16/32
Standard HP Dynamic Smart Array B140i (10
port SATA)
Storage Controller Choice of HP Flexible Smart Array or HP Smart
HBA Controllers for performance or additional
features and Smart Storage Battery
Networking 4x1GbE embedded + FlexibleLOM
SAS/SATA Drives LFF (SAS/ SATA): 4LFF
(12G SAS, 6G SATA) SFF (SAS/ SATA): up to 10 SFF (8+2)
NVMe Support
(Non Volatile
Memory Express)
Management iLO 4 v2.0 + OneView
1
64GB Memory will be available in Nov 2014
2 HP2014
iLO4 v2.1 will be available in Nov SMP, HP Intelligent Provisioning v2.0, HP
Value Add SUM 7.0, HP SPP, HP STK, HP RESTful Interface
The information contained herein is subject to change without notice. Authorised HP Channel
224
Tool
Copyright 2014 Hewlett-Packard Development Company, L.P.
Partners Only * Please see speaker notes
DL360 Gen9 options SFF Bay: DVD-RW,VGA/USB 2.0
Option Kit PN: 764632-B21
Bay: 2x SFF Slots Bay: USB 2.0/VGA
Option Kit PN: 764634-B21 SID MOD, Power,
Option Kit PN: 764630-
USB 3.0, UID
B21
Option Kit PN:
Option kit 764640-B21
DS Ear: 764757-B21

Power switch,
Pull-Tab
Left Ear Universal Media Bay USB 3.0/UID
Blank
225
Copyright 2014 Hewlett-Packard Development Company, L.P. The information contained herein is subject to change without notice. Authorised HP Channel
Partners Only
DL360 Gen9 options LFF Power/USB 3.0/UID+SID Kit
Option kit USB 2.0/VGA Kit LFF Option kit PN: 764640-B21
DS Ear: 764757-B21 Option Kit PN: 764638-B21
Option kit:
DVD or DVD-RW drive and
766203-B21
HP DL360 Gen9 LFF Optical Cable

ODD-Blank Pull-Tab Blank Power switch


Left Ear USB 3.0/UID

226
Copyright 2014 Hewlett-Packard Development Company, L.P. The information contained herein is subject to change without notice. Authorised HP Channel
Partners Only
DL360 Gen9 Rear
Option Kit PN: 764642-B21
HP DL360 Gen9 2P LP PCIe Slot CPU2 Kit
HP DL360 Gen9 Serial or
Cable Kit Option Kit PN: 764644-B21
Option Kit PN: 764646- HP DL360 Gen9 2P FH PCIe CPU2/GPU Kit
B21

1st PCI Riser


FlexLOM Secondary PCI
1 Slot
Slot Riser Blank 2nd Power Supply 1st Power Supply
iL Onboard
O 4x1GbE

227
Copyright 2014 Hewlett-Packard Development Company, L.P. The information contained herein is subject to change without notice. Authorised HP Channel
Partners Only
DL360 Gen9 default cable in Model-X /
CTO Server
SAS Cable included in the
755258-B21 HP DL360 Gen9 8SFF CTO Server for P440ar/H240ar

SATA Cable included in the


755259-B21 HP DL360 Gen9 4LFF CTO Server for B140i

228
Copyright 2014 Hewlett-Packard Development Company, L.P. The information contained herein is subject to change without notice. Authorised HP Channel
Partners Only
DL360 Gen9 and GPU Support
RISER rules for CPU2

764644-B21 HP DL360 Gen9 2P FH PCIe Slot CPU2 Kit

This riser includes:


1x Gen3 PCIe x16 FH and GPU Cable Kits

If the Riser Kit 764644-B21 is in the order, you need the 726740-
B21 HP DL360 Gen9 P440ar for 2 GPU Configs' only this AROC
controller is allowed because it has a special heatsink for GPU
support

The Following AROC controllers cannot be selected


- HP Smart Array P440ar/2G FIO Controller
- HP H240ar FIO Smart HBA
229
Copyright 2014 Hewlett-Packard Development Company, L.P. The information contained herein is subject to change without notice. Authorised HP Channel
Partners Only
DL360 Gen9 | 8-SFF Model-X | SATA/SAS
config shows max 8 SFF
HP Smart Array 6GB SATA only
B140i
Onboard
Controller

766207-B21 HP DL360 Gen9 SFF Embed


SATA Cable
P440ar
H240ar 12GB SAS

SSB* for
P-controller
Cable included

HP Smart Array
P840 12GB SAS

766205-B21 HP DL360 Gen9 P840 Card w/


Cable Kit
230 * Smart
Copyright 2014 Hewlett-Packard Development Company, L.P. The information contained herein is subject to change without Storage
notice. Battery 96WHP
Authorised onlyChannel
needed once per
server
Partners Only
DL360 Gen9 | 8-SFF Model-X | SATA/SAS
config shows max 8 SFF + 2 SFF
HP Smart Array
SSB* for P840 12GB SAS / 6GB SATA
P-controller

766205-B21 HP DL360 Gen9 P840 Card w/


Cable Kit
P440ar 12GB SAS P440
SSB* for 12GB SAS
H240ar H240 (SNAP1 FF)
P-controller

Cable included 775927-B21 HP DL360 Gen9 SFF P440/H240


SAS Cbl
HP Smart Array 6GB SATA only
B140i SATA cable incl. in
Onboard the 2 SFF cage Kit
Controller for B140i

766207-B21 HP DL360 Gen9 SFF Embed


SATA Cable
231 * Smart
Copyright 2014 Hewlett-Packard Development Company, L.P. The information contained herein is subject to change without Storage
notice. Battery 96WHP
Authorised onlyChannel
needed once per
server
Partners Only
DL360 Gen9 | 4-LFF Model-X | SATA/SAS
config shows max 4 LFF drives
B140i
Onboard 6GB SATA only
Controller

Cable included
P440ar
H240ar
12GB SAS
SSB* for
P-controller
766211-B21 HP DL360 Gen9 LFF P440ar/H240ar
SAS Cbl

P440
12GB SAS

775929-B21 HP DL360 Gen9 LFF P440/H240 SAS


Cables
232 * Smart
Copyright 2014 Hewlett-Packard Development Company, L.P. The information contained herein is subject to change without Storage
notice. Battery 96WHP
Authorised onlyChannel
needed once per
server
Partners Only
DL180 Gen9
Value Prop: Feature optimized for essential
datacenter needs

Copyright 2014 Hewlett-Packard Development Company, L.P. The information contained herein is subject to change without notice.
HP ProLiant DL180 Gen9
Launch

Operating System

Up to (2) Intel Xeon E5-2600 v3 up to 105W


Processor
(P0) (12C)
Power Supply 85%, 550 W Multi output non-redundant

GPU Support

HP SmartMemory 16xDDR4 up to 2133 MHz,


Memory Subsystem
support for 8/16/32 GB
Standard HP Dynamic Smart Array B140i (10
Storage Controller port SATA)
and stand up PCIe SAS controllers (H240/P440)
Networking 2x1GbE embedded
SAS/SATA Drives LFF (SAS/ SATA): 4LFF/8LFF NHP , 8LFF, 12LFF
(12G SAS, 6G SATA) SFF (SAS/ SATA): up to 16 SFF (8+8)

NVMe Support

Management HP iLO 4 v2.0 + HP OneView


1
64GB Memory will be available in Nov 2014
HP SUM 7.0, HP SPP, HP STK, HP RESTful
Value
2
Add
iLO4 v2.1 will be available in Nov 2014
InterfaceTool, HP Intelligent Provisioning v2.0
234
Copyright 2014 Hewlett-Packard Development Company, L.P. The information contained herein is subject to change without notice. Authorised HP Channel
Compliance
Partners Only * Please see speaker notes
DL180 Gen9 4LFF and 8LFF / None Hot
Plug
HP DL180 Gen9 NHP LFF CTO Chassis 754525-B
This is same chassis as 8LFF NHP, only the backplane
(sheet metal) is different

FIO Ear Options:


Thumbscrew Ear [default]
Field Field
Latch Ears [option]
Upgrade Downgrade Drive Cage Option:
NO NO No
ODD Option:
No

HP DL180 Gen9 NHP LFF CTO Chassis 754525-B

235
Copyright 2014 Hewlett-Packard Development Company, L.P. The information contained herein is subject to change without notice. Authorised HP Channel
Partners Only
DL180 Gen9 - LFF

HP DL180 Gen9 HP 8LFF CTO Chassis 754524-B21


FIO Ear Options:
Latch Ears (no thumbscrew ear option)
Drive Cage Option:
+ 4LFF
ODD Option:
No
Field
Upgrade
YES HP DL180 Gen9 HP 12LFF CTO Chassis 775506-B21
FIO Ear Options:
Latch Ears (no thumbscrew ear option)
Drive Cage Option:
No
ODD Option:
No

236
Copyright 2014 Hewlett-Packard Development Company, L.P. The information contained herein is subject to change without notice. Authorised HP Channel
Partners Only
DL180 Gen9 SFF Hot Plug
HP DL180 Gen9 HP 8SFF CTO
Chassis 754523-B21
FIO Ear Options:
Thumbscrew Ear [default]
Latch Ears
Drive Cage Option:
8SFF
ODD Option:
ODD enablement kit Possible with 8+8
PN: 725582-B21
SFF FPIO cage

HP DL180 Gen9 HP 8SFF CTO


Chassis 754523-B21
FIO Ear Options:
Thumbscrew Ear
Latch Ears [showing]
Drive Cage Option:
8SFF
ODD Option:
Possible with 8+8
SFF FPIO cage
only w/tap
237
Copyright 2014 Hewlett-Packard Development Company, L.P. The information contained herein is subject to change without notice. Authorised HP Channel
Partners Only
DL180 Gen9 SFF Hot Plug
8 SFF HDD cage kit
Front ODD enablement kit PN: 725572-B21
PN: 725582-B21

2nd Drive Cage Blank SFF FPIO cage

238
Copyright 2014 Hewlett-Packard Development Company, L.P. The information contained herein is subject to change without notice. Authorised HP Channel
Partners Only
DL180 Gen9 - Rear
2nd PCI Riser Cage
PN: 725569-B21 3x PCIe x8
PN: 725570-B21 1x PCIe x8 / 1x PCIe x16
Dedicated iLO Port
PN: 725581-B21

1st PCI Riser


PN: 725569-B21 3x PCIe x8 2x 1GbE and
Shared iLO 500W PowerSupply
PN: 725570-B21 1x PCIe x8 / 1x
PCIe x16 port

239
Copyright 2014 Hewlett-Packard Development Company, L.P. The information contained herein is subject to change without notice. Authorised HP Channel
Partners Only
DL180 Gen9 - Power Supply Option

Power Supply 500W


Non Red.
PN: 730941-B21

Field Field
Upgrade Upgrade
YES NO
R&R

Power Supply Option kit


Redundant and Hot-Plug
2x PN: 744689-B21, PSU 900W
1x PN: 745813-B21, Backplan

Avail. December 2014

240
Copyright 2014 Hewlett-Packard Development Company, L.P. The information contained herein is subject to change without notice. Authorised HP Channel
Partners Only
DL180 Gen9 4LFF / None Hot Plug ENTRY

config shows max 4 LFF drives

HP Smart Array 6GB SATA only


B140i
Onboard Controller
776447-B21 FIO HP DL180 Gen9 4LFF NHP Cable Kit

12GB SAS
HP H240 Smart HBA

776447-B21 FIO HP DL180 Gen9 4LFF NHP Cable Kit

No Drive Cage upgrade possible


Only B140i and H240 supported

241 * Smart
Copyright 2014 Hewlett-Packard Development Company, L.P. The information contained herein is subject to change without Storage
notice. Battery 96WHP
Authorised onlyChannel
needed once per
server
Partners Only
DL180 Gen9 8LFF / None Hot Plug ENTRY

config shows max 8 LFF drives

HP Smart Array 6GB SATA only


B140i
Onboard Controller
774869-B21 FIO HP DL180 Gen9 8LFF NHP Cable Kit

12GB SAS
HP H240 Smart HBA

774869-B21 FIO HP DL180 Gen9 8LFF NHP Cable Kit

No Drive Cage upgrade possible


Only B140i and H240 supported

242 * Smart
Copyright 2014 Hewlett-Packard Development Company, L.P. The information contained herein is subject to change without Storage
notice. Battery 96WHP
Authorised onlyChannel
needed once per
server
Partners Only
DL180 Gen9 8LFF Hot Plug
config shows max 8 LFF drives
HP Smart Array 6GB SATA only
B140i
Onboard Controller
774868-B21 FIO HP DL180 Gen9 8LFF Hot Plug Cable Kit

12GB SAS

HP H240 Smart HBA

774868-B21 FIO HP DL180 Gen9 8LFF Hot Plug Cable Kit

12GB SAS
HP Smart Array P440/P840

725577-B21 HP DL180 Gen9 8LFF Smart Array Cable Kit

SSB* for Default Thumbscrew


P-controller
243 * Smart
Copyright 2014 Hewlett-Packard Development Company, L.P. The information contained herein is subject to change without Storage
notice. Battery 96WHP
Authorised onlyChannel
needed once per
server
Partners Only
DL180 Gen9 8LFF Hot Plug w/after
market
config shows 12LFF
max 12LFF upg.
drives

HP Smart Array 12GB SAS


P840

SSB* for 725577-B21 HP DL180 Gen9 8LFF Smart Array Cable Kit
P-controller

725574-B21 HP DL180 Gen9 12LFF Enablement Kit


Includes cable (1x36p/1x36p) and (1x36p/1x68p)

HP Smart Array 12GB SAS


P840

244 * Smart
Copyright 2014 Hewlett-Packard Development Company, L.P. The information contained herein is subject to change without Storage
notice. Battery 96WHP
Authorised onlyChannel
needed once per
server
Partners Only
DL180 Gen9 12LFF Hot Plug
config shows max 12 LFF drives

12GB SAS / 6GB SATA

HP Smart Array
P840

All Cable Kits are included in the 12-LFF hot plug


CTO chassis

SSB* for
P-controller

245 * Smart
Copyright 2014 Hewlett-Packard Development Company, L.P. The information contained herein is subject to change without Storage
notice. Battery 96WHP
Authorised onlyChannel
needed once per
server
Partners Only
Low Start
DL180 Gen9 / 8-16SFF Point
Capacity
#= bay standard

SSB*
2 x4
1 x2
HP Smart Array
B140i
Onboard Controller
6G SATA only

246 * Smart
Copyright 2014 Hewlett-Packard Development Company, L.P. The information contained herein is subject to change without Storage
notice. Battery 96WHP
Authorised onlyChannel
needed once per
server
Partners Only
DL180 Gen9 / 8-16SFF Performance
#= bay standard
725572- standard 725572- standard
B21 B21

3 2 3 2 3

725578-B21
HP DL180 Gen9 8SFF
774870-B21 725578-B21
HP DL180 Gen9 8SFFHP DL180 Gen9 8SFF
2x 725578-B21
HP DL180 Gen9 8SFF
SSB*
Smart Array Cable Kit H240 FIO Cable KitSmart Array Cable Kit Smart Array Cable Kit
(1x68p/2x36p) (2x36p/2x36p) (1x68p/2x36p) (1x68p/2x36p)

1 x8 2 x4 1 x8 2 x8
SA PCI SA PCI SA PCI SA PCI
HP Smart Array HP H240 HP Smart Array HP Smart Array
P440 Smart HBA P440 P840
SAS Card Card SAS Card SAS Card
726736-B21 726907-B21 726736-B21 726897-B21

247 * Smart
Copyright 2014 Hewlett-Packard Development Company, L.P. The information contained herein is subject to change without Storage
notice. Battery 96WHP
Authorised onlyChannel
needed once per
server
Partners Only
DL160 Gen9
Value Prop: Built-in essentials, upgradable to
enterprise class

Copyright 2014 Hewlett-Packard Development Company, L.P. The information contained herein is subject to change without notice.
HP ProLiant DL160 Gen9
Launch

Operating
System
Up to 2 Intel Xeon E5-2600 v3 Series, 4/6/8/10/12
Processor
Cores
Power Supply 550W multi-output

GPU Support

Memory HP Smart Memory (16) DDR4, up to 2133MHz (512GB


Subsystem max)
Standard HP Dynamic Smart Array B140i (10 port
Storage
SATA), 12G SAS via optional HP Flexible Smart Array
Controller
Controller
Networking 2x1GbE embedded
SAS/SATA
LFF (SATA): 4LFF NHP, LFF (SAS/ SATA): 4LFF HP
Drives
SFF (SAS/ SATA): up to 8SFF
(12G SAS, 6G
8 SFF / 4 LFF max, HDD/SSD
SATA)

SCSIe Support
1
64GB Memory will be available in Nov 2014
Management
2
iLO4 v2.1 will be available in Nov 2014 HP iLO 4 v2.0 + HP OneView
HP SUM 7.0, HP SPP, HP STK, HP RESTful InterfaceTool,
249
Value Add 2014 Hewlett-Packard Development Company, L.P. The information contained herein is subject to change without notice.
Copyright Authorised HP Channel
HP Intelligent Provisioning v2.0 * Please see speaker notes
Partners Only
DL160 Gen9 options LFF / Non Hot Plug
726536-B21 HP 9.5mm SATA DVD-ROM Jb Gen9 Kit
726537-B21 HP 9.5mm SATA DVD-RW Jb Gen9 Kit
Quick Release Ear FIO Kit
PN: 774609-B21
ODD

ODD-Blank USB 2.0


Pull-Tab
Default
Thumbscrew ears

250
Copyright 2014 Hewlett-Packard Development Company, L.P. The information contained herein is subject to change without notice. Authorised HP Channel
Partners Only
DL160 Gen9 options LFF / Hot Plug
726536-B21 HP 9.5mm SATA DVD-ROM Jb Gen9 Kit
Quick Release Ear FIO Kit 726537-B21 HP 9.5mm SATA DVD-RW Jb Gen9 Kit
PN: 774609-B21 ODD

ODD-Blank USB 2.0


Pull-Tab
Default
Thumbscrew ears

251
Copyright 2014 Hewlett-Packard Development Company, L.P. The information contained herein is subject to change without notice. Authorised HP Channel
Partners Only
DL160 Gen9 options SFF
Front USB 3.0 enablement 726536-B21 HP 9.5mm SATA DVD-ROM Jb Gen9 Kit
726537-B21 HP 9.5mm SATA DVD-RW Jb Gen9 Kit
kit FIO PN: 725582-B21
ODD
Quick Release Ear FIO Kit
PN: 774609-B21

Pull-Tab
ODD-Blank
Default USB 2.0
Thumbscrew ears

252
Copyright 2014 Hewlett-Packard Development Company, L.P. The information contained herein is subject to change without notice. Authorised HP Channel
Partners Only
DL160 Gen9 options Rear
HP Dedicated iLO Management Port Kit
PN: 725581-B21 PCI Slot 2
LP or FlexLOM Slot PCI Slot 3
(Dec.) LP

PCI Slot 1
FH/HL

2x 1GbE 900W Red. PSU


Avail. Dec14

253
Copyright 2014 Hewlett-Packard Development Company, L.P. The information contained herein is subject to change without notice. Authorised HP Channel
Partners Only
Low Start
Point
DL160 Gen9 | 4-LFF NHP Model-X Capacity
config shows max 4 LFF drives only B140i supported

HP Smart Array 6GB SATA only


B140i
Onboard Controller Cable included in CTO Server
754522-B21 HP ProLiant DL160 Gen9 Non
Hot-Plug 4LFF Configure-to-order Server

254 * Smart
Copyright 2014 Hewlett-Packard Development Company, L.P. The information contained herein is subject to change without Storage
notice. Battery 96WHP
Authorised onlyChannel
needed once per
server
Partners Only
DL160 Gen9 | 4-LFF Hot Plug Model-XCapacity
config shows max 4 LFF drives

HP Smart Array 6GB SATA only


B140i
Onboard Controller Need Cable Kit
HP DL160 Gen9 4LFF HP cable FIO kit
(768775-B21)

12GB SAS
HP H240 Smart HBA

Need Cable Kit


HP DL160 Gen9 4LFF w/ H240 Cbl Kit
(725590-B21)

12GB SAS
HP Smart Array P440

Need Cable Kit


HP DL160 Gen9 4LFF w/ P440 Cbl Kit (725593-
B21)

SSB* for
P-controller
255 * Smart
Copyright 2014 Hewlett-Packard Development Company, L.P. The information contained herein is subject to change without Storage
notice. Battery 96WHP
Authorised onlyChannel
needed once per
server
Partners Only
DL160 Gen9 | 8-SFF Hot Plug Model-X
Performance

config shows max 8 SFF drives

HP Smart Array 6GB SATA only


B140i
Onboard Controller Need Cable Kit
HP DL160 Gen9 8SFF HP cable FIO kit
(774611-B21)

HP H240 Smart HBA 12GB SAS

Need Cable Kit


HP DL160 Gen9 8SFF w/ H240 Cbl Kit
(774621-B21)

12GB SAS
HP Smart Array P440

Need Cable Kit


HP DL160 Gen9 8SFF w/ P440 Cbl Kit (774619-
B21)

SSB* for
P-controller
256 * Smart
Copyright 2014 Hewlett-Packard Development Company, L.P. The information contained herein is subject to change without Storage
notice. Battery 96WHP
Authorised onlyChannel
needed once per
server
Partners Only
ML350 Gen9
Value Prop: HPs best all-in-one server with maximum expandability, serviceability and
reliability

Copyright 2014 Hewlett-Packard Development Company, L.P. The information contained herein is subject to change without notice.
D
HP ProLiant ML350 Gen9
N

Launch

Operating System

Processor Up to (2) E5-2600 v3 up to 145W (P0) (18C)


Power Supply 94-96%, FlexSlot PS
Single/Double-Wide & Active/Passive up to
GPU Support
10.5 (4) NVIDIA Quadro
HP SmartMemory 24xDDR4 up to 2133 MHz,
Memory Subsystem
support for 8/16/32
Standard HP Dynamic Smart Array B140i
Choice of HP Flexible Smart Array or HP
Storage Controller
Smart HBA Controllers for performance or
additional features
Networking 4x1GbE embedded
LFF (SAS/ SATA): 24 LFF (8+8+8)
SAS/SATA Drives
SFF (SAS/ SATA): up to 48 SFF
(12G SAS, 6G SATA)
(8+8+8+8+8+8)
NVMe Support
(Non Volatile Memory
Express)
1
iLO4 v2.1 will be available in Nov 2014
Management HP iLO 4 v2.0
HP SUM 7.0, HP SPP, HP STK, HP RESTful
258
Value Add 2014 Hewlett-Packard Development Company, L.P. The information contained herein is subject to change without notice. Authorised HP Channel
Copyright
InterfaceTool, HP Intelligent Provisioning v2.0 * Please see speaker notes
Partners Only
ML350 Gen9 options SFF
Option kit: Option kit:
DVD or DVD-RW drive and SID kit
Cable 726563-B21
Option kit:
SFF media
cage
726545-B21

Option kit:
8SFF drive
cage
778157-B21

259
Copyright 2014 Hewlett-Packard Development Company, L.P. The information contained herein is subject to change without notice. Authorised HP Channel
Partners Only
ML350 Gen9 options LFF

Option kit:
LFF media
cage
726561-B21

Option kit:
8LFF drive kit
726547-B21

260
Copyright 2014 Hewlett-Packard Development Company, L.P. The information contained herein is subject to change without notice. Authorised HP Channel
Partners Only
ML350 Gen9 Rear

2nd power
supply

3rd power
supply
4th power
supply

261
Copyright 2014 Hewlett-Packard Development Company, L.P. The information contained herein is subject to change without notice. Authorised HP Channel
Partners Only
Option kit 725878-B21:
redundant fan / PCIe baffle

262
Copyright 2014 Hewlett-Packard Development Company, L.P. The information contained herein is subject to change without notice. Authorised HP Channel
Partners Only
Max config on Launch 48 SFF / 24 LFF

max config SFF (48) max config LFF (24)


B140 P440 P440a
P840 P440 B140i P840 P440
i ar r

Option 1 1 5 Option 1 1 2

Option 2 5 1 Option 2 2 1

Option 3 6 Option 3 3

Option 4 2 1 1 Option 4 1 1
Option 5 2

Storage Expander will be supported later


263
Copyright 2014 Hewlett-Packard Development Company, L.P. The information contained herein is subject to change without notice. Authorised HP Channel
Partners Only
ML350 Gen9 | 8-SFF Model-X | SATA/SAS
config shows max 16 SFF
B140i
6GB SATA only
Onboard
Controller

765654-B21 HP ML350 Gen9 Mini SAS cable Kit (incl.


2 x4 cable)
SSB* for P440ar
12GB SAS
P-controller H240ar

765652-B21 HP ML350 Gen9 AROC cable Kit (incl. 2 x4 cable)


SSB* for
12GB SAS
P-controller
P840

765650-B21 HP ML350 Gen9 SA cable Kit (incl. 2 Y-cable


x8 x4) * Smart Storage Battery 96WHP
onlyChannel
needed once per
264
Copyright 2014 Hewlett-Packard Development Company, L.P. The information contained herein is subject to change without notice. Authorised
server
Partners Only
ML350 Gen9 | 8-LFF Model-X | SATA/SAS
config shows max 16 LFF drives
B140i
Onboard 6GB SATA only
Controller

765654-B21 HP ML350 Gen9 Mini SAS cable Kit (incl. 2 x4


cable)
SSB* for P440ar
P-controller H240ar
12GB SAS / 6GB SATA

765652-B21 HP ML350 Gen9 AROC cable Kit (incl. 2 x4


cable)

SSB* for 12GB SAS / 6GB SATA


P840
P-controller

765650-B21 HP ML350 Gen9 SA cable Kit (incl. 2 Y-


cable x8 x4)
265 * Smart
Copyright 2014 Hewlett-Packard Development Company, L.P. The information contained herein is subject to change without Storage
notice. Battery 96WHP
Authorised onlyChannel
needed once per
server
Partners Only
ML350 Gen9 | 8-LFF Model-X | SATA/SAS
config shows max 24 LFF drives
HP Smart Array
HP Smart Array P440
P440ar

HP Smart Array
HP Smart Array P440
P440ar

266
Copyright 2014 Hewlett-Packard Development Company, L.P. The information contained herein is subject to change without notice. Authorised HP Channel
Partners Only
ML350 Gen9 | 8-LFF Model-X | SATA/SAS
config shows max 24 LFF drives
HP Smart Array
HP Smart Array P440
P440

HP Smart Array
HP Smart Array P440
P440

267
Copyright 2014 Hewlett-Packard Development Company, L.P. The information contained herein is subject to change without notice. Authorised HP Channel
Partners Only
Thank you

Copyright 2014 Hewlett-Packard Development Company, L.P. The information contained herein is subject to change without notice.

Вам также может понравиться