VSD Workshop

ATV12, ATV21, ATV312, ATV61, ATV71

Schneider Electric Vietnam Vinh Tung Feb 2011 1


Check the connection diagram ATV12

Schneider Electric Vietnam Vinh Tung Feb 2011 2


Check the connection diagram ATV21

Schneider Electric Vietnam Vinh Tung Feb 2011 3


Check the connection diagram ATV312

Schneider Electric Vietnam Vinh Tung Feb 2011 4


Check the connection diagram ATV61/71

Schneider Electric Vietnam Vinh Tung Feb 2011 5


Examine the factory setting of ATV12

Schneider Electric Vietnam Vinh Tung Feb 2011 6


Examine the factory setting of ATV21

Schneider Electric Vietnam Vinh Tung Feb 2011 7


Examine the factory setting of ATV312

Schneider Electric Vietnam Vinh Tung Feb 2011 8


Examine the factory setting of ATV61

Schneider Electric Vietnam Vinh Tung Feb 2011 9


Examine the factory setting of ATV71

Schneider Electric Vietnam Vinh Tung Feb 2011 10


Workshop
1) Return to the factory settings
ATV12: Conf/ FCS = InI (2s)
ATV21: tYP = 3
ATV312: drC/ FCS = InI (2s)
ATV61/71: Factory Settings/ Parameter Group List = All, Goto Factory Settings

2) Start the motor with the HMI at 15Hz


ATV12: Conf/ Fr1 = AIV1
ATV21: CMOd = 1, FMOd = 3
ATV312: CtL/ Fr1 = AIV1
I-O/ tCC = LOC
ATV61/71: Command/ Ref.1 channel = HMI

3) Start the motor with the Terminals at +/-25Hz


ATV12: Conf/ Fr1 = AI1
Conf/ FULL/ Fun/ rrS = L2H
ATV21: CMOd = 0, FMOd = 1
F112 = 3, F311 = 0
ATV312: CtL/ Fr1 = Ai1
I-O/ tCC = 2C, rrS = LI2
ATV61/71: Command/ Ref.1 channel = AI1
Inputs-Outputs Cfg/ Reverse assign. = LI2

Schneider Electric Vietnam Vinh Tung Feb 2011 11


Workshop
4) Set R2 (or LO1 or RY-RC) to Frequency reference reached
ATV12: Conf/ FULL/ I-O/LO1/LO1 = SrA
ATV21: F130 = 6
ATV312: I-O/ r2 = SrA
ATV61/71: Inputs-Outputs Cfg/ R2 configuration/ R2 assignment = Freq.ref.att
5) Set preset speeds with LI
(LI4=0 LI3=0): 50Hz (LI4=1 LI3=0): 10Hz
(LI4=0 LI3=1): 20Hz (LI4=1 LI3=1): 25Hz
ATV12: Conf/ FULL/ Fun/ PSS/ PS2 = L3H, PS4 = L4H
SP2 = 20, SP3 = 10, SP4 = 25
ATV21: F112 = 6, F113 = 7
Sr1 = 20, Sr2 = 10, Sr3 = 25
ATV312: Fun/ PSS/ PS2 = LI3, PS4 = LI4
SP2 = 20, SP3 = 10, SP4 = 25
ATV61/71: Application Funct./ Preset speeds/ 2 preset speeds = LI3, 4 preset speeds = LI4
preset speed 2 = 20 Hz preset speed 3 = 10 Hz preset speed 4 = 25 Hz
6) Run the motor at 80Hz
ATV12: COnF/ FULL/ drC/ tFr = 90Hz
HSP = 80Hz
ATV21: FH = 90, UL = 80, F204 = 80
ATV312: drC/ tFr = 90Hz
Set/ HSP = 80Hz
ATV61/71: Motor Control/ Max frequency = 90Hz
Settings/ High speed = 80Hz

Schneider Electric Vietnam Vinh Tung Feb 2011 12


Workshop

7) Input the motor parameters and make an Autotune


ATV12: COnF/ FULL/ drC/ bFr, nPr, UnS, nCr, FrS, nSP
tUn = YES -> dOnE
ATV21: uL, uLu, F415, F417, THr = F415
F400 =2
ATV312: drC/ bFr, UnS, FrS, nCr, nSP, COS
tUn = YES -> dOnE
Set/ ItH =(nCr)
ATV61/71: Motor Control/ BFR, NPR, UNS, NCR, FRS, NSP
Auto tuning = YES -> DONE
Settings/ Mot. Thermal current = (NCR)

8) Compare the motor current at 10Hz and 50Hz


without load for the different control laws
Change the control law ATV12: COnF/FULL/drC/Ctt
ATV21: Pt
ATV312: drC/Uft
ATV61/71: Motor Control/ Motor control type

ATV12 ATV21 ATV312 ATV61 ATV71 10Hz 50Hz


PErF 3 n SVC V SVC V normal normal
Std 0 L U/F 2pts U/F 2pts normal normal
PUMP 1 P U/F Q - low normal
- 2 nLd En.Sav. - low low

Schneider Electric Vietnam Vinh Tung Feb 2011 13


Workshop

9) Examine the different control laws and the related parameters

ATV12 Ctt Std PUMP PErF


Ufr x x x IR compensation

SLP x x Slip compensation


PFL x Flux profile
STA x Stability
FLG x Gain

ATV312 UFt L P n nLd


Ufr x x x x Voltage boost or IR comp.
SLP x x Slip compensation
STA x x Stability
FLG x x Gain

Schneider Electric Vietnam Vinh Tung Feb 2011 14


Workshop

Examine the different control laws and the related parameters

ATV61 CTT SVCV U/F U/F Q En.Sav.


UFR x x IR compensation

SLP x x Slip
PFL x compensation
U0 x x Flux profile
SPG x x Boost
SIT x x Gain
Time integral
ATV71 CTT SVCV U/F SVCI FVC
UFR x x x
SLP x x x IR compensation
U0 x Slip
SPG x x x compensation
SIT x x x Boost
Gain
Schneider Electric Vietnam Vinh Tung Feb 2011 Time integral 15
Workshop ATV12 ATV312

10) Compare the different motor control laws

U
UnS 100 100 100

PFL

FrS F FrS F FrS F Tn T

T T T T

Tn Tn Tn Tn

FrS F FrS F FrS F FrS F

U/F (Std, L) U/F Q (PUMP, P) SVC (PErf, n) Energy Saving (nLd)

Schneider Electric Vietnam Vinh Tung Feb 2011 16


Compatibility of functions for ATV12

Schneider Electric Vietnam Vinh Tung Feb 2011 17


Compatibility of functions for ATV21

Schneider Electric Vietnam Vinh Tung Feb 2011 18


Compatibility of functions for ATV312

Schneider Electric Vietnam Vinh Tung Feb 2011 19


Compatibility of functions for ATV61

Schneider Electric Vietnam Vinh Tung Feb 2011 20


Compatibility of functions for ATV71

Schneider Electric Vietnam Vinh Tung Feb 2011 21


PID function of ATV12

Schneider Electric Vietnam Vinh Tung Feb 2011 22


PID function of ATV21

LI = ICLR (65)
References Integral
Shunt
FMOD
Auto/manu
Terminal VIB Internal
+ reference
Keypad PID Regulator
Ramp
-
gP F362
gI F363 UL ACC
gD F366 F359 PID LL DEC
Activation
PID feedback Time
VIA
0-10V Scaling
0-4-20mA F360 (PID active)
LI = PID (14)

F201
F204

Speed reference active

Schneider Electric Vietnam Vinh Tung Feb 2011 23


PI function of ATV312

Schneider Electric Vietnam Vinh Tung Feb 2011 24


PID function of ATV61/71

Schneider Electric Vietnam Vinh Tung Feb 2011 25


Workshop
11) Set the PID function with
AI1 as feedback, internal reference of 50%
ATV12: COnF/ FULL/ CtL/ Fr1 = AIV1
CHCF = SEP
COnF/ FULL/ Fun/ Pid/ PIF = AI1
PII = yES
rPI = 50.0
ATV21: CMOd = 0 (terminal), FMOd = 3 (HMI)
F360 = 1 (enable PID with VIA)
Set reference = 25Hz (ref PID 50%)

ATV312: FUn/ SAI/ SA2 = nO


Fun/ PSS/ PS2 = nO, PS4 = nO
FUn/ PI/ PIF = AI1
PII = yES
rPI = 50.0

ATV61/71: APPLICATION FUNCT./ PID REGULATOR/


PID feedback ass. = AI1
Max PID feedback = 1000
Acti. Internal PID ref. = Yes
Internal PID ref. = 500
Min PID output = 0Hz
Max PID output = +50Hz
MONITORING/
PID reference, feedback, error, output
Schneider Electric Vietnam Vinh Tung Feb 2011 26
Workshop
12) Set the Sleep function at 25Hz after 10s,
the Wake-up function when feedback<20%
ATV12: COnF/ LSP = 25.0
COnF/ FULL/ Fun/ Pid/
tLS = 10.0
UPP = 20.0
ATV21: LL = 25.0 (low speed)
F256 = 10.0 (time at low speed)
F392 = 15.0 (wake up at PI error 30%)

ATV312: SEt/
LSP = 25.0
tLS = 10.0
rSL = 30.0
ATV61: APPLICATION FUNCT./ SLEEPING WAKE UP/
Low speed time out = 10s
Low speed = 25Hz
PID Wakeup threshold (UPP) = 200
ATV71: SETTINGS/ Low speed = 25Hz
APPLICATION FUNCT./ PID REGULATOR/
Low speed time out = 10s
PID wakeup threshold (RSL) = 30.0

Schneider Electric Vietnam Vinh Tung Feb 2011 27


Workshop

13) Save the current configuration in drive memory


ATV12: Conf/ SCS = Str1
ATV21: tYP = 7
ATV312: drC/ SCS = Str1
ATV61/71: OPEN / SAVE AS/ SAVE AS/ File 1-4

14) Retrieve the backup configuration


ATV12: Conf/ FCS = rEC1
ATV21: tYP = 8
ATV312: drC/ FCS = rEC1
ATV61/71: OPEN / SAVE AS/ OPEN/ File 1-4

Schneider Electric Vietnam Vinh Tung Feb 2011 28


Workshop
15) Set the drive ready for Modbus communication
Address 1, baud rate 19.2kbps, format 8E1 (do a Factory setting first)
ATV12: Conf/ FULL/ COM/ Add = 1
tbr =19.2, tt0 = 8E1
COnf/ Fr1 = Mdb
ATV312: COM/ Add = 1
tbr = 19.2, tf0 = 8E1
CtL/ LAC = L3
Fr1 = Mdb
ATV61/71: COMMUNICATION/ MODBUS NETWORK/
Modbus Address = 1
Modbus baud rate = 19.2 kbps, Modbus format = 8E1
COMMAND/ Ref.1 channel = Modbus

Schneider Electric Vietnam Vinh Tung Feb 2011 29