Вы находитесь на странице: 1из 52

S PTD HP - Power Transmission and Distribution

Power Transmission and Distribution

PGINA: 1 TEORIA E CONCEPO DE DISJUNTORES


S PTD HP - Power Transmission and Distribution
Power Transmission and Distribution
DISJUNTORES: TEORIA E CONCEPO

PGINA: 2 TEORIA E CONCEPO DE DISJUNTORES


S PTD HP - Power Transmission and Distribution
Power Transmission and Distribution
DISJUNTORES TEORIA E CONCEPO

PROGRAMA

1- Conceitos bsicos;
2- Definies;
3- Principais normas aplicveis;
4- Disjuntores - Siemens;
5- Plos / Unidade de Interrupo;
6- Painel de comando / Acionamento;
7- Consideraes gerais;

PGINA: 3 TEORIA E CONCEPO DE DISJUNTORES


S PTD HP - Power Transmission and Distribution
Power Transmission and Distribution
DISJUNTORES TEORIA E CONCEPO

DISJUNTORES
72,5 a 800kV

1- Conceitos
Bsicos.

PGINA: 4 TEORIA E CONCEPO DE DISJUNTORES


S PTD HP - Power Transmission and Distribution
Power Transmission and Distribution
1- CONCEITOS BSICOS

PROJETO DE TRANSMISSO

CONSUMO

TRANSMISSO E
GERAO DISTRIBUIO

PGINA: 5 TEORIA E CONCEPO DE DISJUNTORES


S PTD HP - Power Transmission and Distribution
Power Transmission and Distribution
1- CONCEITOS BSICOS

TRANSMISSO E
DISTRIBUIO

PGINA: 6 TEORIA E CONCEPO DE DISJUNTORES


S PTD HP - Power Transmission and Distribution
Power Transmission and Distribution
1- CONCEITOS BSICOS

TRANSMISSO E
DISTRIBUIO

EQUIPAMENTOS
DE MANOBRA

O QUE SO EQUIPAMENTOS DE MANOBRA ?

PGINA: 7 TEORIA E CONCEPO DE DISJUNTORES


S PTD HP - Power Transmission and Distribution
Power Transmission and Distribution
SECIONADORES TEORIA E CONCEPO

DISJUNTORES
72,5 a 800kV

2- Definies

PGINA: 8 TEORIA E CONCEPO DE DISJUNTORES


S PTD HP - Power Transmission and Distribution
Power Transmission and Distribution
2. Definies

Equipamentos de manobra:
So dispositivos mecnicos, que na posio aberta
asseguram uma distncia de isolamento e na posio
fechada mantm a continuidade do circuito eltrico

DISTNCIA DE
ISOLAMENTO

POSIO ABERTA POSIO FECHADA

PGINA: 9 TEORIA E CONCEPO DE DISJUNTORES


S PTD HP - Power Transmission and Distribution
Power Transmission and Distribution
2. Definies
Equipamentos de manobra:
Disjuntores Secionadores

Disjuntor um dispositivo mecnico de manobra, capaz de


estabelecer, conduzir e interrromper correntes nas condies
normais do circuito, assim como estabelecer, conduzir durante um
tempo especificado e interromper correntes sob condies
anormais especificadas do circuito, tais como as de curto-circuito
PGINA: 10 TEORIA E CONCEPO DE DISJUNTORES
S PTD HP - Power Transmission and Distribution
Power Transmission and Distribution
2. Definies

O Disjuntores de alta tenso, frequentemente denominados


disjuntores de potncia, so os principais elementos de
segurana, bem como os mais eficientes e complexos
aparelhos de manobra em uso nas redes eltricas.

Possuem uma capacidade de fechamento e de ruptura que


deve atender a todos os requisitos preestabelecidos de
manobra sob as condies normais e anormais de operao.

PGINA: 11 TEORIA E CONCEPO DE DISJUNTORES


S PTD HP - Power Transmission and Distribution
Power Transmission and Distribution
2. Definies

No estado ligado (fechado) o disjuntor deve suportar a


corrente nominal de linha sem que venha a se aquecer alm
de limites permissveis

No estado desligado (aberto) a distncia de isolamento entre


contatos deve suportar a tenso de operao, bem como
sobretenses internas, devido a surto de manobras ou
descargas atmosfricas

PGINA: 12 TEORIA E CONCEPO DE DISJUNTORES


S PTD HP - Power Transmission and Distribution
Power Transmission and Distribution
2. Definies

PORTANTO, uma confiabilidade total exigida do disjuntor


de potncia e esta confiabilidade deve ser conseqncia de:
Projeto racional

Controle de qualidade
Escolha da matria prima
Reviso de entrada
Controle dos processos de fabricao
Ensaios subconjuntos e finais

PGINA: 13 TEORIA E CONCEPO DE DISJUNTORES


S PTD HP - Power Transmission and Distribution
Power Transmission and Distribution
DISJUNTORES TEORIA E CONCEPO

DISJUNTORES
72,5 a 800kV

3- Normas
aplicveis

PGINA: 14 TEORIA E CONCEPO DE DISJUNTORES


S PTD HP - Power Transmission and Distribution
Power Transmission and Distribution
3. Principais Normas Aplicveis
As Normas Tcnicas tem por finalidade definir parmetros e mtodos padronizados
para verificar e garantir as caractersticas funcionais e de aplicaes dos Equipamentos.

ABNT-NBR-7118 - Disjuntores de Alta Tenso - Especificao


ABNT-NBR-5389 - Tcnicas de Ensaios Eltricos de Alta Tenso -
Mtodo de Ensaio
ABNT-NBR-6936 - Tcnicas de Ensaios Eltricos de Alta Tenso -
Procedimento
ABNT-NBR-5034 - Buchas para Equipamento Eltrico de Tenso
Superior a 1 kV - Especificao
ABNT-NBR-5051 - Buchas para Equipamento Eltrico de Tenso
Superior a 1 kV - Mtodo de Ensaio
ABNT-NBR-6939 - Coordenao de Isolamento - Procedimento
ABNT-NBR-7038 - Guia para Ensaios de Disjuntor em Condies de
Discordncia de Fases - Procedimento.

PGINA: 15 TEORIA E CONCEPO DE DISJUNTORES


S PTD HP - Power Transmission and Distribution
Power Transmission and Distribution
3. Principais Normas Aplicveis

Tipos principais de disjuntores

Disjuntora sopro magntico


Disjuntor a leo
Grande volume de leo
Pequeno volume de leo
Disjuntores a vcuo
Disjuntores a ar comprimido
Disjuntores a SF6

PGINA: 16 TEORIA E CONCEPO DE DISJUNTORES


S PTD HP - Power Transmission and Distribution
Power Transmission and Distribution
DISJUNTORES TEORIA E CONCEPO

DISJUNTORES
72,5 a 800kV

4- Disjuntores
Siemens

PGINA: 17 TEORIA E CONCEPO DE DISJUNTORES


S PTD HP - Power Transmission and Distribution
Power Transmission and Distribution
4. Disjuntores - Siemens
Desenvolvimento dos disjuntores de AT a SF6 na Siemens

1952 A Siemens comea a pesquisar os princpios de extino do arco voltaico em


gs SF6 no departamento de Fsica do Plasma de seu Laboratrio de Pesquisa

1956 A Siemens constri um prottipo do disjuntor a SF6

1957/58 Construo de um disjuntor de mdia tenso (36 kV) a SF6 com princpio de
dupla presso

1962 Incio do desenvolvimento do disjuntor de alta tenso a SF6 para 123 kV

1964/65 Primeiro disjuntor a SF6 para 242 kV, 2 cmaras de interrupo por plo,
sistema de dupla presso e acionamento a ar comprimido

PGINA: 18 TEORIA E CONCEPO DE DISJUNTORES


S PTD HP - Power Transmission and Distribution
Power Transmission and Distribution
4. Disjuntores - Siemens
Desenvolvimento dos disjuntores de AT a SF6 na Siemens
(continuao)

1965 Incio do fornecimento dos disjuntores a SF6 para kV e 40 kA

1966 5 dias de experincias de interrupo com as maiores potncias de curto--


circuito possveis na poca na rede da maior concessionria Alem, a RWE.
O disjuntor a SF6 de 245 kV, interrompeu correntes de at 40 kA de forma
totalmente satisfatria.

1968/69 Disjuntor a SF6 para 245 kV com 2 cmaras de extino por plo.
Substituio do acionamento pneumtico pelo j aprovado acionamento
eletro-hidrulico. Disjuntor SF6 para 420 kV, com 4 em vez de 6 cmaras de
extino por plo.

1974 Entrega dos primeiros disjuntores 3AS4 para 420 kV, 63 kA

PGINA: 19 TEORIA E CONCEPO DE DISJUNTORES


S PTD HP - Power Transmission and Distribution
Power Transmission and Distribution
4. Disjuntores - Siemens
Desenvolvimento dos disjuntores de AT a SF6 na Siemens
(continuao)

06/77 Concorrncia CDI para fabricao de disjuntores de alta tenso a SF6 no


Brasil.

12/77 Entrega do projeto de nacionalizao da Siemens S.A ao CDI.

06/78 Aprovao do projeto de nacionalizao dos seguintes concorrentes:


SIEMENS S.A, DELLE ALSTHOM, posteriormente BBC.

02/80 Incio da fabricao dos disjuntores a SF6 no Brasil (3AS1/145 kV).

05/82 Constituio da empresa INSAT atravs do Joint Venture da Siemens e


Mendes Jr.

PGINA: 20 TEORIA E CONCEPO DE DISJUNTORES


S PTD HP - Power Transmission and Distribution
Power Transmission and Distribution
4. Disjuntores - Siemens
Desenvolvimento dos disjuntores de AT a SF6 na Siemens
(continuao)

10/83 Incio da fabricao de disjuntores a SF6 em prdio prprio. Aps o estudo de


vrias alternativas foi escolhido o parque industrial da Lapa, tempo em vista a
infra-estrutura j existente.

10/84 Fornecimento dos primeiros disjuntores 3AT2 - 460 kV (Eletropaulo).

06/87 Fornecimento do disjuntor de numero 250.

02/90 Final do Projeto CDI. Com isso terminam todas as obrigaes junto ao CDI,
inclusive a Joint Venture. Sada da empresa Mendes Jr.

10/90 A INSAT torna-se novamente Siemens S.A

06/95 Fornecimento do primeiro disjuntor 550 kV, 63 kA para Chesf - Brasil, de


fabricao Brasileira

PGINA: 21 TEORIA E CONCEPO DE DISJUNTORES


S PTD HP - Power Transmission and Distribution
Power Transmission and Distribution
4. Disjuntores - Siemens
Desenvolvimento dos disjuntores de AT a SF6 na Siemens
(continuao)

01/04 Mudana da PTD HP LAPA para o site de Jundia

10/04 Aquisio da empresa Lorenzetti Alta Tenso - Secionadores

01/05 Fabricao de secionadores de Alta Tenso na PTD HP Jundia

06/05 Aquisio mundial das empresa Trench (TIs)

11/05 Aquisio mundial da empresas Vatech (disjuntores)

08/06 Fabricao de disjuntores Vatech na PTD HP Jundia

05/07 Ampliao do site de Jundia (Presidente Luis Incio LULA da Silva)

PGINA: 22 TEORIA E CONCEPO DE DISJUNTORES


S PTD HP - Power Transmission and Distribution
Power Transmission and Distribution
4. Tipos de Disjuntores - Siemens
Brasil PTD HP

Fabricao de disjuntores de alta tenso de 72,5 kV at 800 kV


Fabricao de secionadores de 15 kV at 800 kV

Comercializao de pra-raios de 12kV at 800 kV


Comercializao de TPCs de 72,5kV at 800 kV

PGINA: 23 TEORIA E CONCEPO DE DISJUNTORES


S PTD HP - Power Transmission and Distribution
Power Transmission and Distribution
4. Disjuntores - Siemens
Tipos de disjuntores

Tipo 3AP1/3AQ1 3AP2/3AQ2 3AT2/3 3AT4/5


Tenso nominal [kV] 72,5 123 145 170 245 300 362 420 245 300 362 420 550 362 420 550 800

Tenso nominal a 140 230 275 325 460 460 520 610 460 460 520 610 800 520 610 800 1150
frequncia industrial
[kV]
Tensode impulso 325 550 650 750 1050 1050 1175 1425 1050 1050 1175 1425 1550 1175 1425 1550 2100
atmosfrico [kV]

Tenso de impulso de - - - - - 850 950 1050 - 850 950 1050 1175 950 1050 1175 1425
manobra [kV]

Corrente nominal, at 4000 4000 4000 4000 4000 4000 4000 4000 4000 4000 4000 4000 4000 4000 4000 4000 4000
[A]
Corrente de curto 40 40 40 40 40 40 50 50 80 63 63 63 63 80 80 63 63
circuito at [kA]

PGINA: 24 TEORIA E CONCEPO DE DISJUNTORES


S PTD HP - Power Transmission and Distribution
Power Transmission and Distribution
4. Disjuntores - Siemens
Disjuntores com acionamento a mola

3AP1 FG 3AP1 FI 3AP2/3


PGINA: 25 TEORIA E CONCEPO DE DISJUNTORES
S PTD HP - Power Transmission and Distribution
Power Transmission and Distribution
4. Disjuntores - Siemens
Disjuntores com acionamento hidrulico

3AT 2/3 3AT 4/5

PGINA: 26 TEORIA E CONCEPO DE DISJUNTORES


S PTD HP - Power Transmission and Distribution
Power Transmission and Distribution
4. Disjuntores - Siemens

Cm Tenso Corr. Mecanismo Religam


TIPO Base Plo Nominal Nominal ento
kV A Tipo Quant.

3AP1 Comum 1 72,5 / at 4000 FA2,3 1 Tripolar


FG 145 / Ex. 013
245

3AP1 FI Indivi- 1 145 / at FA2,4 3 Mono-


dual 245 4000 Ex. 017 polar

3AP2/3 Indivi- 2 72,5 at FA5 3 Mono-


dual 4000 polar

3AT2/3 Indivi- 2 245 a at 3 Mono-


dual 500 kV 5000 A Hidru- polar
lico

3AT4/5 Indivi- 2 345 a at 3 Mono-


dual 800 kV 5000 A Hidru- polar
lico
PGINA: 27 TEORIA E CONCEPO DE DISJUNTORES
S PTD HP - Power Transmission and Distribution
Power Transmission and Distribution
DISJUNTORES TEORIA E CONCEPO

DISJUNTORES
72,5 a 800kV

5- Plos /
Unidade de
Interrupo

PGINA: 28 TEORIA E CONCEPO DE DISJUNTORES


S PTD HP - Power Transmission and Distribution
Power Transmission and Distribution
5. Plos / Unidade de Interrupo

Plos / Unidade

PGINA: 29 TEORIA E CONCEPO DE DISJUNTORES


S PTD HP - Power Transmission and Distribution
Power Transmission and Distribution
5. Plos / Unidade de Interrupo - Siemens

3AP1 FI
PGINA: 30 TEORIA E CONCEPO DE DISJUNTORES
S PTD HP - Power Transmission and Distribution
Power Transmission and Distribution
5. Plos / Unidade de Interrupo - Siemens

3AP1 FI
PGINA: 31 TEORIA E CONCEPO DE DISJUNTORES
S PTD HP - Power Transmission and Distribution
Power Transmission and Distribution
5. Plos / Unidade de Interrupo - Siemens

Contato de arco fixo


Bocal de extino
Dedos de contato
Contato de arco
mvel
Cilindro de
aquecimento
Vlvula de reteno
Vlvula de
aquecimento

FECHADO ABERTO
PGINA: 32 TEORIA E CONCEPO DE DISJUNTORES
S PTD HP - Power Transmission and Distribution
Power Transmission and Distribution
5. Plos / Unidade de Interrupo - Siemens

3AP1 FG
PGINA: 33 TEORIA E CONCEPO DE DISJUNTORES
S PTD HP - Power Transmission and Distribution
Power Transmission and Distribution
DISJUNTORES TEORIA E CONCEPO

DISJUNTORES
72,5 a 800kV

6- Painel de
Comando /
Acionamento

PGINA: 34 TEORIA E CONCEPO DE DISJUNTORES


S PTD HP - Power Transmission and Distribution
Power Transmission and Distribution
6. Painel de Comando / Acionamento

Painel de Comando

PGINA: 35 TEORIA E CONCEPO DE DISJUNTORES


S PTD HP - Power Transmission and Distribution
Power Transmission and Distribution
6. Painel de Comando / Acionamento

Acionamento
Por mola, tipo FA 2
Peso
130 kg
Tenso do motor
60 a 250 V CC
Potncia motor
800 W
Tenso de controle
60 a 250 V CC
Potncia bobina
300 W
Carga manual da mola
30 voltas

PGINA: 36 TEORIA E CONCEPO DE DISJUNTORES


S PTD HP - Power Transmission and Distribution
Power Transmission and Distribution
6. Painel de Comando / Acionamento

Acionamento a Mola

PGINA: 37 TEORIA E CONCEPO DE DISJUNTORES


S PTD HP - Power Transmission and Distribution
Power Transmission and Distribution
6. Painel de Comando / Acionamento

Cuidados na manobra
- No manobrar o mecanismo a mola sem estar
acoplado no disjuntor.

-No manobrar o disjuntor sem que esteja com


a presso mnima para operao mecnica.

- Perigo de quebra.

PGINA: 38 TEORIA E CONCEPO DE DISJUNTORES


S PTD HP - Power Transmission and Distribution
Power Transmission and Distribution
DISJUNTORES TEORIA E CONCEPO

DISJUNTORES
72,5 a 800kV

7-
Consideraes
Gerais

PGINA: 39 TEORIA E CONCEPO DE DISJUNTORES


S PTD HP - Power Transmission and Distribution
Power Transmission and Distribution
7. Consideraes Gerais

Denominao dos disjuntores de alta tenso - Siemens


3A (a) (b) (c) (d)

3A - disjuntor tripolar

(a) tipo do disjuntor


P Disjuntor com cmara tipo auto extino
Q Disjuntor com cmara tipo pisto insuflador (puffer type)
T Disjuntor com cmara tipo pisto insuflador (2 ciclos)

(b) - nmero de cmaras por plo


1 uma cmara por plo
2 duas cmaras por plo
3 duas cmaras por plo com resistor de pr-insero
4 quatro cmaras por plo
5 quatro cmaras por plo com resistor de pr-insero
PGINA: 40 TEORIA E CONCEPO DE DISJUNTORES
S PTD HP - Power Transmission and Distribution
Power Transmission and Distribution
7. Consideraes Gerais

Denominao dos disjuntores de alta tenso - Siemens


3A (a) (b) (c) (d)

(c) Acionamento
E mecanismo de acionamento hidrulico
F mecanismo de acionamento a mola

(d) disposio dos plos


G base nica
I base individual

Exemplo: 3AP1 FG 145kV


Disjuntor tripolar utilizando como meio de isolante e de extino o gs
SF6 (hexafluoreto de enxofre), acionamento a mola, com ploes
sobre uma mesma base (somente religamento tripolar), para
sistemas em 145kV
PGINA: 41 TEORIA E CONCEPO DE DISJUNTORES
S PTD HP - Power Transmission and Distribution
Power Transmission and Distribution
7. Consideraes Gerais
Representao da Documentao
Contatos dos densmetros esto representados em estado sem presso
Todos os contatos esto representados em estado desenergizado
Chaves auxiliares representadas na posio aberta dos disjuntores

Documentao dos esquemas eltricos consistem nos


seguintes tpicos:
Caractersticas Gerais
Disposio dos componentes
Esquema eltrico
Lista de componentes
Lista de bornes

PGINA: 42 TEORIA E CONCEPO DE DISJUNTORES


S PTD HP - Power Transmission and Distribution
Power Transmission and Distribution
7. Consideraes Gerais

Estrutura Geral
Centralizao de todos os componentes em um nico armrio de comando.

Bloqueio geral
- No caso de insuficincia de presso impede a abertura ou fechamento do
disjuntor
- O bloqueio geral afetar os trs plos, por se tratar de um acionamento comum

PGINA: 43 TEORIA E CONCEPO DE DISJUNTORES


S PTD HP - Power Transmission and Distribution
Power Transmission and Distribution
7. Consideraes Gerais

Bloqueio de Fechamento
- Presso de SF6 baixa a valores inadmissveis
- Comando de fechamento no desligado


Bloqueio de Abertura
Presso de SF6 baixa a valores inadmissveis ( reao a B4 K10 )

PGINA: 44 TEORIA E CONCEPO DE DISJUNTORES


S PTD HP - Power Transmission and Distribution
Power Transmission and Distribution
7. Consideraes Gerais

CIRCUITO DE FECHAMENTO

S8 - Chave local remoto


S9 Botoeira ( fechamento local )
S1 - Chave auxiliar
S16 - Chave carregamento da mola
Y1 Disparador de fechamento
K75 - Contator ( antibombeamento )
K10 Bloqueio geral
K111 Superv. Bobina Fechamento

PGINA: 45 TEORIA E CONCEPO DE DISJUNTORES


S PTD HP - Power Transmission and Distribution
Power Transmission and Distribution
7. Consideraes Gerais

CIRCUITO DE ABERTURA

S8 Chave local remoto


S3 Botoeira ( Abertura local )
S1 - Chave auxiliar
K10 Bloqueio Geral
K112 Supervisor de bobina
Y3 Disparador de abertura

PGINA: 46 TEORIA E CONCEPO DE DISJUNTORES


S PTD HP - Power Transmission and Distribution
Power Transmission and Distribution
7. Consideraes Gerais

CIRCUITO DE COMANDO

B4 - Densmetro ( contatos 21, 22, 23 )


K10 - Bloqueio geral
S1 - Chave auxiliar ( contato passante )
P1 - Contador de operaes

PGINA: 47 TEORIA E CONCEPO DE DISJUNTORES


S PTD HP - Power Transmission and Distribution
Power Transmission and Distribution
7. Consideraes Gerais

COMANDO MOTOR DO ACIONAMENTO

F1 Disjuntor de proteo do motor


S16 Chave auxiliar carregamento da mola
M1 motor do acionamento

PGINA: 48 TEORIA E CONCEPO DE DISJUNTORES


S PTD HP - Power Transmission and Distribution
Power Transmission and Distribution
7. Consideraes Gerais
ALARME E SINALIZAO

B4 - Densmetro ( contatos 11, 12, 13) / 5,2-0,2 bar


K10 Bloqueio geral
S16 Bloqueio mecanismo de fechamento
S8 Chave local
S16 Mola de fechamento descarregada
K111/112/113 Superv. de bobinas

PGINA: 49 TEORIA E CONCEPO DE DISJUNTORES


S PTD HP - Power Transmission and Distribution
Power Transmission and Distribution
7. Consideraes Gerais

AQUECIMENTO / ILUMINAO /
TOMADA

R1 a R6 - Resistores de aquecimento
E1 - Lmpada
S10 - Chave fim de curso
X106 Tomada
S10 e S11 Chave Fim de curso

PGINA: 50 TEORIA E CONCEPO DE DISJUNTORES


S PTD HP - Power Transmission and Distribution
Power Transmission and Distribution
7. Consideraes Gerais

CONTATOS AUXILIARES RESERVAS

S1 - Chave auxiliar disjuntor

PGINA: 51 TEORIA E CONCEPO DE DISJUNTORES


S PTD HP - Power Transmission and Distribution
Power Transmission and Distribution
7. Consideraes Gerais

OBRIGADO !

lucas.vasconcellos@siemens.com

PGINA: 52 TEORIA E CONCEPO DE DISJUNTORES

Вам также может понравиться