Вы находитесь на странице: 1из 84

2G and 3G Training

www.huawei.com

Copyright 2010 Huawei Technologies Co., Ltd. All rights reserved.


The Frequency Spectrum
GSM 900

Uplink Downlink

890 915 935 960MHz

Duplex Separation: 45MHz


Channel Bandwidth: 200KHz

Copyright 2010 Huawei Technologies Co., Ltd. All rights reserved.


The Frequency Spectrum
DCS 1800

Base Station Receive Base Station Transmit

1710 1785 1805 1880MHz

Duplex Separation: 95MHz


Channel Bandwidth: 200KHz

Copyright 2010 Huawei Technologies Co., Ltd. All rights reserved.


Cell Types

Omni
Omni-directional Cell
1

1
120
120 Degree Cell degree 2
3
Copyright 2010 Huawei Technologies Co., Ltd. All rights reserved.
Contents
1. GSM System Overview
2. GSM Network Structure

Copyright 2010 Huawei Technologies Co., Ltd. All rights reserved.


GSM(2G) Network Component

Copyright 2010 Huawei Technologies Co., Ltd. All rights reserved.


UMTS (3G) Network Component
UE UTRAN CN
Uu Iu

Iu-CS
RNC
Iub
Iu-BC
CS
NodeB

Iu-PS

Iur

NodeB PS
Iu-BC

Iub

NodeB
RNC
CBC

Copyright 2010 Huawei Technologies Co., Ltd. All rights reserved.


BTS3900(A) System Overview
Outdoor BTS
Indoor BTS BTS 3900A
BTS 3900

Indoor macro
cabinet

BTS3900 BTS3900A
Copyright 2010 Huawei Technologies Co., Ltd. All rights reserved.
DBS3900 System Overview
DBS3900 components:
BBU3900
Antenna
RRU3908, RRU3804, RRU3008
TMA
RRU3908
RF jumper
Grounding cable
MBSC Feeder

Power cable
RF jumper
CPRI cable

BBU3900
Grounding cable
Trunk cable Power cable

Copyright 2010 Huawei Technologies Co., Ltd. All rights reserved.


Board configuration principles of the BBU3900
BBU3900 board includes: GTMU, WMPTWBBPUBFAUPEU
UEIU UELP UFLPUTRP.
Board Optional/ Maximum Slot
Configuration Limitations
Name Mandatory Number

GTMU Mandatory 1 Slot 5 Slot 6 Configured in slot 5 & 6 .

UBFA Mandatory 1 FAN Only configured in the FAN slot

UPEU Mandatory 2 PWR1 or PWR2 Preferentially configured in the PWR2 slot in the case of a single UPEU

UEIU Optional 1 PWR1 -

UFLP Optional 2 Slot 0 or slot 4 Preferentially configured in slot 4

Typical configuration of the BBU3900

Copyright 2010 Huawei Technologies Co., Ltd. All rights reserved.


GTMU
The GSM transmission, timing, and management unit for BBU (GTMU)
controls and manages the entire BTS. It provides interfaces related to
the reference clock, power supply, OM, and external alarm collection.
The GTMU performs the following functions:
Controls, maintains, and operates the BTS.
Supports fault management, configuration management, performance
management, and security management.
Supports the monitoring of the fan module and power supply module.
Distributes and manages BTS3900 clock signals.
Provides clock input for testing.
Provides port for terminal maintenance.
Supports four E1 inputs.
Provides CPRI ports for communication with the RF modules .

Copyright 2010 Huawei Technologies Co., Ltd. All rights reserved.


GTMU (Cont.)
Connecto
Port Description
r Type

CPRI0 to Ports for the communication between the BBU and the RF module; support
SFP
CPRI5 input and output of the optical and electrical signal.

EXT (GTMUb) SFP Obligate

ETH RJ45 Port for local maintenance and commissioning.


Connects the BBU to a routing device in the equipment room through the
FE0 RJ45
Ethernet cable to transmit network information.
Connects the BBU to a routing device in the equipment room through the
FE1 DLC
optical cable to transmit network information.
USB USB Enables the automatic software upgrade from a USB disk.
TST USB Provides a reference clock for the tester.
DB26 Provides four E1/T1 inputs and outputs between the GTMU and the UELP or
E1/T1
female BSC

Copyright 2010 Huawei Technologies Co., Ltd. All rights reserved.


WMPT
IP transmission on Loading Testing:USB GPS antenna: SMA
Electrical Port :RJ45

LEDs
Commissioning:RJ45 IP transmission
Optical signals: SFP 4E1:DB26

Main Functions
Board number
maximum is 2 for one BBU Providing OM functions
mandatory board Controlling other boards in the system and
working in active and providing the reference clock
standby Providing USB ports for automatic NodeB
upgraded
Providing transmission port for Iub
interface
Providing OM channels
Copyright 2010 Huawei Technologies Co., Ltd. All rights reserved.
WMPT Board
LEDs of running status of WMPT:

Label Color Status Description


RUN Green ON The board has power input, yet the board is faulty.

OFF The board has no power input.

1s ON, 1s OFF The board is running as configured.

0.125s ON, 0.125s OFF The software is being loaded to the board, or the
board is not in use.
ALM Red ON The board is reporting hardware alarms.

OFF The board is running properly.


ACT Green ON The board is in active mode.

OFF The board is in standby mode.

Copyright 2010 Huawei Technologies Co., Ltd. All rights reserved.


WBBP Board
CPRI 0~2 (1.25G-2.5G): SFP LEDs

Board number mandatory board, maximum is 6


Main Functions
Providing the CPRI interface for communication between the BBU and the
WRRU or WRFU
Processing uplink and downlink baseband signals and support HSUPA and
HSDPA function
Supporting 1+1 backup of the CPRI interface
According to the board chip processing capability, WBBP module include
seven specifications. Current WBBP is the A version, called WBBPa.

Copyright 2010 Huawei Technologies Co., Ltd. All rights reserved.


UTRP Board
The UTRP provides ports for eight E1s/T1s and implements transport such as IP
and
ATM between the BBU3900 and the RNC. 4 E1:DB26

Label Color Status Description


RUN Green ON The board has power input, yet the board is faulty.
OFF The board has no power input or is faulty.
1s ON, 1s OFF The board is running properly.

0.125s ON, 0.125s OFF Software is being loaded to the board.


2s ON, 2s OFF The board is under test.
ACT Green ON The board is in active mode.
OFF The board is in standby mode.
ALM Red OFF The board is running properly.
ON The board is reporting alarms and is faulty.

Copyright 2010 Huawei Technologies Co., Ltd. All rights reserved.


UBFA Board

Board number mandatory board, maximum is 1


Main Functions
Controlling the fan speed
Reporting the fan status to the WMPT
Detecting the temperature of the fan board

Label Color Status Description

STATE Green 0.125s ON, The module is not registered, and no


0.125s OFF alarm is reported.

1s ON, 1s OFF The board is running properly.

Red ON The module is reporting alarms.

Copyright 2010 Huawei Technologies Co., Ltd. All rights reserved.


UPEU Board
Panel of the UPEA
Panel of the UPEB

-48V to +12V +24V to +12V

Board number mandatory, maximum is 2, 1+1 backup


Main Functions
Converting -48 V or +24 V DC power input to +12 V DC power that is supported
by boards
Reporting alarms related to input and output under voltage
Providing transmission ports for RS485 signals and 8 dry contact alarm signals

Copyright 2010 Huawei Technologies Co., Ltd. All rights reserved.


UEIU Board
UEIU is the environment interface board of BBU, it can support multi-
route monitoring signal input
UEIU is optional and is only used when more ports are needed

Connector
Label Description
Type
MON0 RJ45 One RS485 signal
MON1 RJ45 One RS485 signal
EXT- Four dry contact
RJ45
ALM0 signals
EXT- Four dry contact
RJ45
ALM1 signals

Copyright 2010 Huawei Technologies Co., Ltd. All rights reserved.


UELP Board
UELP: The universal E1/T1 lightning protection (UELP) unit is a universal E1/T1
The UELP can be optionally installed in the SLPU or the BBU. Each UELP
supports the surge protection of 4-way E1/T1 signals.
DB25 DB26

E1 Connection:

E1
E1

Indoor DDF

Copyright 2010 Huawei Technologies Co., Ltd. All rights reserved.


UFLP Board
UFLP: The universal FE lightning protection (UFLP) board is optionally installed in the
SLPU or BBU. Each UFLP supports 2-way FE surge protection.

IP Cable Connection.
Transmission Equipment
LAN switch or Router

Copyright 2010 Huawei Technologies Co., Ltd. All rights reserved.


Features and Functions of Fan Box
The FAN unit, also called the fan box module, dissipates the
heat in the cabinet. One FAN unit has four independent fans.
Detects the temperature
Communicates with BBU unit to report alarms and the adjusted
rotation speed of the fans to BBU

Copyright 2010 Huawei Technologies Co., Ltd. All rights reserved.


BBU3900 Cable Connection

Copyright 2010 Huawei Technologies Co., Ltd. All rights reserved.


PMU(AC/DC)
The Power and Environment Monitoring Unit (PMU)
provides a comprehensive function of power supply
management, power distribution check, and alarm
reporting.
Communicates with the GTMU through the RS232/RS422 serial port
Manages the power system and the battery charging and
discharging

Detects and reports monitoring signals


1. LEDs
2. Power supply test ports
3. RS232/RS422 ports
4. Battery control switch
5. COM port

Copyright 2010 Huawei Technologies Co., Ltd. All rights reserved.


PSU(AC/DC)
Converting 220 V AC power to -48 V DC power and supplying -48 V DC
power to the DCDU
Monitoring alarms related to module faults (such as output overvoltage,
no output, and fan faults), alarms related to module protection (such as
over temperature protection and input overvoltage/undervoltage
protection), and module out-of-position alarm

1 1 Power running LED


2 2 Protection LED
3 3 Fault LED

Copyright 2010 Huawei Technologies Co., Ltd. All rights reserved.


DCDU
Receiving -48 V DC power input
Distributing the -48 V DC power of 10 outputs for boards and
modules in the cabinet
Providing surge protection of 10 kA in differential mode and 15 kA in
common mode and providing dry contact for surge protection failure

Copyright 2010 Huawei Technologies Co., Ltd. All rights reserved.


Ports on the GRFU
Port Label Function

RF RX port, connecting to the antenna system.


ANT_RXB
RF
ANT_TX/RX RF TX/RX port, connecting to the antenna
A system.

Connecting the BBU or the upper-level


CPRI0
cascaded GRFU.
CPRI
Connecting the BBU or the lower-level
CPRI1
cascaded GRFU.

Inter-GRFU RX_INB Input port for diversity receive.

RF signal RX_OUTA Output port for main receive.

Power Introducing power input.


PWR
supply

Monitoring MON Monitoring and maintaining port.


Copyright 2010 Huawei Technologies Co., Ltd. All rights reserved.
MRFU Ports
Connector
Port Type Label Description
Type
Port for ANT_RXB DIN
Connecting to the antenna
transceiving connector
ANT_TX/RXA subsystem.
RF signals
Connecting to the BBU, or the
CPRI0 upper-level RFU during the
SFP female cascading.
CPRI
connector
Connecting to the lower-level
CPRI1
RFU during the cascading.

Input port of diversity signals


Interconnecti RX_INB in the
on port for antenna channel.
QMA female
RF
connector Output port of diversity
Receive
signals RX_OUTA signals in the
antenna channel.
Power supply 3V3 power
PWR Feeding power.
port connector
Monitoring RJ45 RS485 Monitoring
MON
port connector debugging port.

Copyright 2010 Huawei Technologies Co., Ltd. All rights reserved.


MRFU LED
Label Status Description

The power input is normal, but the module is


ON
faulty.
There is no power input, or the module is
OFF
faulty.
RUN
ON for 1s and OFF for 1s The module is running properly.

ON for 0.125s and OFF The module is loading software or is not


for 0.125s started.
ON The module is in the alarm status.
ALM
OFF No alarm is generated.
The module is functional and is connected to
ON
the BBU.
ACT OFF The module is not connected to the BBU.

ON for 1s and OFF for 1s The module is in the local test status.

Copyright 2010 Huawei Technologies Co., Ltd. All rights reserved.


MRFU LED

Label Status Description

OFF (red) No VSWR alarm is generated.


VSWR
ON (red) A VSWR alarm is generated.
ON (green) The CPRI link is normal.

ON (red) The interface module fails to receive signals.


CPRI0
ON for 1s and OFF for
The CPRI link is out of lock.
1s (red)
ON (green) The CPRI link is normal.

ON (red) The interface module fails to receive signals.


CPRI1
ON for 1s and OFF for
The CPRI link is out of lock.
1s (red)

Copyright 2010 Huawei Technologies Co., Ltd. All rights reserved.


RRU Module
The RRU module has a bottom
panel, a cabling cavity panel,
and an area attached with
LEDs.

Provides - 48VDC power


supply.

1 Bottom panel

2 Cabling cavity panel

3 LEDs

Copyright 2010 Huawei Technologies Co., Ltd. All rights reserved.


RRU Ports
Item Label Description
RX_IN/OUT Interconnection ports for RF signals
RET RET antenna port
Bottom panel
ANT_TX/RXA RF TX/RX port A
ANT_TX/RXB RF TX/RX port B
RTN+
Power wire post
NEG-

TX RX CPRI_E Eastern optical port

TX RX CPRI_W Western optical port


Cabling cavity
panel
EXT_ALM Alarm Port
RST Hardware reset button
TST VSWR Test button for VSWR alarms

TST CPRI Test button for the CPRI port

Copyright 2010 Huawei Technologies Co., Ltd. All rights reserved.


RRU LEDs
LED Color Status Description
ON The RRU is faulty.
OFF No power input is available.
RUN Green 1s ON,1s OFF The RRU runs properly.
ON for 0.25s
The software is being loaded.
OFF for 0.25s
ON or Blinking
The RRU is faulty and reporting alarms.
ALM Red (1s ON, 1s OFF)
OFF No alarm is generated.
ON The RRU runs properly.
ACT Green
OFF The connection to the BBU is not established.
OFF No VSWR alarm is generated.
1s ON
A VSWR alarm is generated on the ANT_TX/RXB port.
VSWR 1s OFF
Red
TX_ACT ON A VSWR alarm is generated on the ANT_TX/RXA port.
0.125s ON A VSWR alarm is generated on the ANT_TX/RXA and
0.125s OFF ANT_TX/RXB ports.

Copyright 2010 Huawei Technologies Co., Ltd. All rights reserved.


RRU LEDs
Green The CPRI link is functional.

The reception of the optical module is


Red
CPRI_W abnormal and an alarm is generated.
Red or
(westward
green Blinking red
CPRI LED) The CPRI link has a loss-of-lock error.
0.25s ON, 0.25s OFF

The SFP module is not in position or the


OFF
optical module is powered off.
Green The CPRI link is functional.
The reception of the optical module is
Red
abnormal and an alarm is generated.
CPRI_E
Red or
(eastward CPRI Blinking red
green The CPRI link has a loss-of-lock error.
LED) 0.25s ON, 0.25s OFF

The SFP module is not in position or the


OFF
optical module is powered off.

Copyright 2010 Huawei Technologies Co., Ltd. All rights reserved.


Transmission E1/T1 Cable Connection

Figure 1 Figure 2

If... Then...
The co- Link the DB26 male connector of the E1/T1 cable to
transmission the port labeled E1/T1 on the GTMU, and then
mode is used tighten the screws, as shown in Figure 1.
The separate Link the DB26 male connectors of two E1/T1 cables
transmission to the ports labeled E1/T1 on the GTMU and on the
mode is used WMPT respectively, as shown in Figure 2.
Copyright 2010 Huawei Technologies Co., Ltd. All rights reserved.
Transmission FE/GE Cable Connection

If... Then...
The separate Connect one FE/GE cable to the port labeled FE0 on
transmission mode the WMPT/LMPT and another FE/GE cable to the
is used port labeled FE0 on the GTMU.

Copyright 2010 Huawei Technologies Co., Ltd. All rights reserved.


Transmission FE/GE Cable Connection

If... Then...
The co-transmission mode Connect the FE/GE cable to the port
over the electrical port is used labeled FE0 on the WMPT/LMPT.
Connect the two ends of the
interconnection cable between the FE
optical ports to the ports labeled FE1 on
the GTMU and on the WMPT/LMPT
respectively.
Copyright 2010 Huawei Technologies Co., Ltd. All rights reserved.
Transmission FE/GE Cable Connection

If... Then...
The co- Connect the FE/GE optical cable to the port labeled FE1 on
transmission the WMPT/LMPT.
mode over the Connect the two ends of the interconnection cable between
optical port is the FE electrical ports to the ports labeled FE0 on the GTMU
used and on the WMPT/LMPT respectively
NOTE:
The FE/GE optical cable should be wrapped a winding pipe,

Copyright 2010 Huawei Technologies Co., Ltd. All rights reserved.


CPRI Cable Connections
GSM only

Star topology Chain topology


Copyright 2010 Huawei Technologies Co., Ltd. All rights reserved.
CPRI Cable Connections
GSM + LTE

Dual-star topology over CPRI cable connections


CPRI ports in co-cabinet mode
Copyright 2010 Huawei Technologies Co., Ltd. All rights reserved.
CPRI Cable Connections
GSM + UMTS

Dual-star topology CPRI cable connections in a co-cabinet


over CPRI ports base station with WRFUs and DRFUs/GRFUs
Copyright 2010 Huawei Technologies Co., Ltd. All rights reserved.
CPRI Cable Connections
GSM + UMTS + LTE
Example: GU + LO

CPRI cable connections for a base station configured with


six GSM+UMTS RFUs, three UMTS only RFUs, and three LTE only RFUs

Copyright 2010 Huawei Technologies Co., Ltd. All rights reserved.


Local maintenance 2G (GSM)
Connect the maintenance terminal computer with the ETH port on
TMU by crossed cable.

Setting ip in your laptop, for example 192.168.0.14/24

Copyright 2010 Huawei Technologies Co., Ltd. All rights reserved.


Login Site Maintenance Terminal

Copyright 2010 Huawei Technologies Co., Ltd. All rights reserved.


Site Maintenance Terminal
Navigation Pane
View Pane

Status Pane

Copyright 2010 Huawei Technologies Co., Ltd. All rights reserved.


Upgrading Software through SMT
In the left pane of the Site
Maintenance Terminal System
window, select Board. In the right
pane of the window, double-click
Board Management

Copyright 2010 Huawei Technologies Co., Ltd. All rights reserved.


Querying Board Information
query the board running state, software version, board alarm count,
current clock state, board in-position information, and clock
master/backup state.

Copyright 2010 Huawei Technologies Co., Ltd. All rights reserved.


Checking the Boards Software
Version
Right-click MRFU0,and GTMU and then click Board Information. The
query is successful. The Board Information dialog box is displayed

Copyright 2010 Huawei Technologies Co., Ltd. All rights reserved.


Download all boards one by one

Copyright 2010 Huawei Technologies Co., Ltd. All rights reserved.


Activate all boards one by one

Copyright 2010 Huawei Technologies Co., Ltd. All rights reserved.


Reset a board
initialize the parameters associated with a board

Copyright 2010 Huawei Technologies Co., Ltd. All rights reserved.


Test a Board
check whether the hardware of the board is damaged

Copyright 2010 Huawei Technologies Co., Ltd. All rights reserved.


Query Port Attributes
query the availability status, management status, active/standby status,
and physical property of ports.

Copyright 2010 Huawei Technologies Co., Ltd. All rights reserved.


Manage Cells
The cell management involves
managing cell attributes and cell
extended attributes, testing all the
BTs and RCs of a cell so that they
can be locked or unlocked, and
checking whether the BTs and RCs
are functional.

Copyright 2010 Huawei Technologies Co., Ltd. All rights reserved.


Change the Cell Management
State
Lock or Unlock the BTs and RCs of a cell.

Copyright 2010 Huawei Technologies Co., Ltd. All rights reserved.


Manage BTs
The BT management involves locking
or unlocking a BT, resetting a BT,
performing the RC self-test, view the
status of the channels on a specified
BT, and enabling a specified RC to
transmit signals at a predefined power
level.

Copyright 2010 Huawei Technologies Co., Ltd. All rights reserved.


Change the BT Management State
Lock or Unlock a BT.

Copyright 2010 Huawei Technologies Co., Ltd. All rights reserved.


View the Channel Status
Query the status of all the channels on a BT.

Copyright 2010 Huawei Technologies Co., Ltd. All rights reserved.


Managing Channels
The channel management involves
viewing and setting channel
attributes, locking or unlocking a
channel, and checking the quality
of a channel by testing the
parameters such as the bit error
ratio (BER) and transmit power.

Copyright 2010 Huawei Technologies Co., Ltd. All rights reserved.


Managing RCs
The RC management involves
setting the attributes and
extended attributes of an RC,
locking or unlocking an RC,
resetting an RC, and adjusting
power of an RC automatically.

Copyright 2010 Huawei Technologies Co., Ltd. All rights reserved.


Local maintenance 3G (UMTS)
Setting Laptop IP : 17.21.2.33 / 255.255.255.0

User : admin

Password : NodeB

IP :17.21.2.15

Copyright 2010 Huawei Technologies Co., Ltd. All rights reserved.


MML Command

Fill the Command :


REQ CMCTRL
LST SOFTWARE
Main Area V200R013C00SPC339 Available 2012-03-30 00:22:57
Standby Area V200R012C00SPC411 Available NULL

Copyright 2010 Huawei Technologies Co., Ltd. All rights reserved.


LST SOFTWARE:;

Copyright 2010 Huawei Technologies Co., Ltd. All rights reserved.


LST VER:;

Copyright 2010 Huawei Technologies Co., Ltd. All rights reserved.


Download Software and Script
Maintenance Software Update Upgrade NodeB
Software

Copyright 2010 Huawei Technologies Co., Ltd. All rights reserved.


Check list parameter

Copyright 2010 Huawei Technologies Co., Ltd. All rights reserved.


Save backup script to your PC

Copyright 2010 Huawei Technologies Co., Ltd. All rights reserved.


Download Script from your PC

Copyright 2010 Huawei Technologies Co., Ltd. All rights reserved.


Download NodeB Software from your PC

Copyright 2010 Huawei Technologies Co., Ltd. All rights reserved.


Steps after commisioning
MML Command :
DSP E1T1
LST IUBCP
Port Type = CCP Port
CP Port No. = 0
Belong Flag = MASTER
Transport Channel Flag = Master
Bearer Type = IPV4
Link No. = 1
(Number of results = 1)

LST SCTPLNK
LST ALMAF
DSP VSWR

Copyright 2010 Huawei Technologies Co., Ltd. All rights reserved.


Step 1: Check the transmission status

DSP E1T1:
If the status isnt Normal , please refer to the NodeB trouble shooting.
Copyright 2010 Huawei Technologies Co., Ltd. All rights reserved.
Step 2: Check the transmission status

DSP IMAGRP:;
If the status isnt Normal , please refer to the NodeB trouble shooting.
Copyright 2010 Huawei Technologies Co., Ltd. All rights reserved.
Step 3: commissioning the transmission
Check the status of NBAP by DSP IUBP:;

If the status isnt Normal , please refer to the NodeB trouble shooting.

Copyright 2010 Huawei Technologies Co., Ltd. All rights reserved.


Check the status of ALCAP by DSP AAL2NODE:;

If the status isnt Normal , please refer to the NodeB trouble shooting.

Copyright 2010 Huawei Technologies Co., Ltd. All rights reserved.


Check the status of AAL2PATH by DSP AAL2PATH:;

If the status isnt Normal , please refer to the NodeB trouble shooting.

Copyright 2010 Huawei Technologies Co., Ltd. All rights reserved.


Step 3: Check the local cell status

IF local status unavailable or have faults please refer to the NodeB trouble
shooting.
Copyright 2010 Huawei Technologies Co., Ltd. All rights reserved.
Step 4: Check the VSWR Value

Note: The value must be less than 1.5, normally it should be 1.3 or less.
Others please refer to the NodeB trouble shooting.

Copyright 2010 Huawei Technologies Co., Ltd. All rights reserved.


Do Basic Service Verification
Send and Receive SMS

Outgoing and Incoming Voice Call

Outgoing and Incoming Video Call

Browsing Internet

View Board RTWP and Cell Service Resource Query


Normal RTWP Value (-100dBm until -110 dBM)

Copyright 2010 Huawei Technologies Co., Ltd. All rights reserved.


Page 78
Sample of Normal RTWP Value

Copyright 2010 Huawei Technologies Co., Ltd. All rights reserved.


Page 79
Copyright 2010 Huawei Technologies Co., Ltd. All rights reserved.
Page 80
Cell Service Resource Query

Copyright 2010 Huawei Technologies Co., Ltd. All rights reserved.


Page 81
NOTES:

If the upper items are not available, check the lower layer
status

Check the ATM layer negotiating parameters

Check the physical lower parameters

All the command parameters please get help from the


online help information

Copyright 2010 Huawei Technologies Co., Ltd. All rights reserved.


Summary
This course describes the local maintenance of the BTS,
including tools, checking the hardware and the replacing of
hardware and software. A routine maintenance list is
included as well.

Copyright 2010 Huawei Technologies Co., Ltd. All rights reserved.


Thank you
www.huawei.com

Вам также может понравиться