Preface
Antenna
In the transmit direction: The service signal is transmitted to the main ODU and the standby ODU
after traversing the cross-connect board. Then, the service signal is transmitted to the antenna
through the hybrid coupler. In normal cases, the standby ODU is muted. After the switching, the main
ODU is muted and the standby ODU starts to work.
In the receive direction: The service signal received at the antenna is transmitted to the cross-
connect board through the main ODU and the standby ODU. The cross-connect board selects the
signal transmitted
HUAWEI from theCO.,
TECHNOLOGIES mainLTD.IF board.Huawei Confidential Page 6
1+1 SD Traditional Microwave
Muted
Main
Main ODU IF board
Cross-connect board
Service board
Antenna 1
Antenna 2
Standby
Standby ODU
IF board
Muted
In the case of the IDU 620, the main IF board and the standby IF board must be installed in paired
slots.
In the receive direction: The main IF board and the standby IF board transmit the received service
signal to each other. When a fault occurs on the main channel or the quality of the service on the
main channel declines, the main ODU selects the service signal transmitted from the standby IF
HUAWEI TECHNOLOGIES CO., LTD. Huawei Confidential Page 7
board (HSM switching).
1+1 FD Traditional Microwave
tf1
Main
rf1 Main ODU IF board
Cross-connect board
Service board
Hybrid coupler
Antenna
Compared with the 1+1 SD protection, the 1+1 FD protection uses two frequencies.
The main ODU and the standby ODU both transmit signals.
HSB (Switching on the Equipment Side HSM (Switching on the Channel Side
) )
1+1 HSB
1+1 SD
1+1 FD
Switching The service signal is selected at the cross-connect board. The service signal is selected at the IF board.
position
Switching Automatic switching: hardware fault of the IF board, Automatic switching: loss of microwave signals, loss
condition hardware fault of the ODU, remote fault indication, and of microwave frames, bit errors in microwave frames, and
loss of microwave frames
forced selection of the service signal from the IF board in
Switching triggered by external commands: lockout of
protection, forced switching, manual switching, and clear the paired slot triggered by the HSB switching
switching Switching triggered by external commands:
commands of forcibly selecting the service signal from the
IF board in the paired slot and clearing the forced
selection
Slot The main IF board and the standby IF board need not be In the case of the IDU 620, the main IF board and the standby IF
restriction installed in the paired slots. board must be installed in the paired slots.
Switching < 500 ms The hardware performs the automatic switching action quickly.
time The software and the hardware perform the switching During the switching process, bit errors do not occur.
action.
Revertive The revertive mode and the non-revertive mode are Regardless of whether the switching is set to the revertive mode
switching supported. The wait-to-restore (WTR) time can be set to or the non-revertive mode, the IF board attempts to perform a
5 to 12 minutes. revertive switching action every two minutes after the HSM
switching.
Switching Single-ended switching Single-ended switching
mode
In the case of the 1+1 HSB/SD/FD protection for the IDU 605 2F, the MUX unit of the main IF board multiplexes the
accessed E1 and Ethernet services into Hybrid microwave frames and then transmits the Hybrid microwave frames
to the processing units of the main IF board and the standby IF board. The realization principle is the same as the
relation principle of the 1+1 HSB/SD/FD protection for the traditional microwave of the IDU 605 V100R001. Hence,
details about the realization principle are not provided in this course.
1+1 HSB/SD/FD protection for the IFH2 of the IDU 620
In the case of the TDM service, the cross-connect board performs the dual transmission and selective
receiving of services because the backplane is connected to the cross-connect board.
In the case of the Ethernet services transmitted over the Hybrid microwave, the 1+1 HSB/FD/SD protection
requires the cooperation of the IFH2 board and the EMS6 board because the service that traverses the IFH2
board and the EMS6 board is not dually transmitted and selectively received at the cross-connect board.
The 1+1 HSB/SD/FD protection described in the following slides refers to the 1+1 HSB/SD/FD protection for the
IFH2 board of the IDU 620.
When the GE interface of the standby IF board is disabled, the Ethernet service is transmitted through the
GE interface of the main IF board.
After the 1+1 HSB switching occurs between the main IF board and the standby IF board, the GE
interface of the former working (main) IF board is disabled and the GE interface of the protection (standby)
IF board is enabled. The GE interface of the protection (standby) IF board starts to access the Ethernet
service transmitted from the EMS6 board. Thus, the switching between the main IF board and the standby
IF board is realized.
The IDU 620 supports one to two 1+1 HSB protection groups. One 1+1 HSB protection group uses one
channel and consists of the following items:
Two IFH2 boards: The 1+1 HSB does not require that the IF boards must be installed in paired slots. It is
recommended, however, that you install a pair of the main IF board and the standby IF board in slots 5
and 7 (the IF board in slot 5 functions as the main board), or in slots 6 and 8 (the IF board in slot 6
functions as the main board).
One EMS6 board: It is recommended that you install the EMS6 board in slot 4.
Two ODUs that are of the same type
One hybrid coupler: The hybrid coupler can be balanced or unbalanced. Generally, the unbalanced
hybrid coupler is used.
One antenna
The IDU 620 supports one to two 1+1 SD protection groups. One 1+1 SD protection group uses one channel
and consists of the following items:
Two IFH2 boards: A pair of the main IF board and the standby IF board must be installed in slots 5 and 7
(the IF board in slot 5 functions as the main board), or in slots 6 and 8 (the IF board in slot 6 functions as
the main board).
One EMS6 board: It is recommended that you install the EMS6 board in slot 4.
Two ODUs that are of the same type
Two antennas
The IDU 620 supports one to two 1+1 FD protection groups. One 1+1 FD protection group uses two channels
and consists of the following items:
Two IFH2 boards: A pair of the main IF board and the standby IF board must be installed in slots 5 and 7
(the IF board in slot 5 functions as the main board), or in slots 6 and 8 (the IF board in slot 6 functions as
the main board).
One EMS6 board: It is recommended that you install the EMS6 board in slot 4.
Two ODUs: The two ODUs can work on different sub-frequency bands. The other information about the
two ODUs, however, must be consistent.
One antenna (with one balanced hybrid coupler), as shown in the figure in the upper left corner; or two
antennas, as shown in the figure in the upper right corner
IDU 605 2F
The IDU 605 2F supports one 1+1 HSB protection group. One 1+1 HSB protection group uses one channel
and consists of the following items:
One IDU 605 2F: In the case of the IDU 605 2F, the main/standby relation between the IF units is fixed
and planning is not required.
Two ODUs that are of the same type
One hybrid coupler: The hybrid coupler can be balanced or unbalanced. Generally, the unbalanced
hybrid coupler is used.
One antenna
The IDU 605 2F supports one 1+1 SD protection group. One 1+1 SD protection group uses one channel and
consists of the following items:
One IDU 605 2F: In the case of the IDU 605 2F, the main/standby relation between the IF units is fixed
and planning is not required.
Two ODUs that are of the same type
Two antennas
The IDU 605 2B/2F supports one 1+1 FD protection group. One 1+1 FD protection group uses two channels
and consists of the following items:
One IDU 605 2F: In the case of the IDU 605 2F, the main/standby relation between the IF units is fixed
and planning is not required.
Two ODUs
One antenna (with one balanced hybrid coupler), as shown in the figure in the upper left corner; or two
antennas, as shown in the figure in the upper right corner
IDU 605 2B
Site C
Site A
IF1B IF1B
IF1B IF1B
PD1
Site A 5-IFH2
EMS
6
Site C
IF1A IFH2
IF1A IFH2
EMS6
In one direction, the services are transmitted over traditional microwave; in the other direction,
the services are transmitted over Hybrid microwave.
IDU 605 2F
Site C
Site A
IFH2 IFH2
IFH2 IFH2
EMS6
In the two directions, the services are transmitted over Hybrid microwave.
7-IFH2
7-IFH2 8-IFH2 5-IFH2
6-IFH2 1+1
IDU 605 1F
5-
IFH2
IFH2 IFH2
5-IFH2
IFH2 IFH2
EMS6
Create an NE to be
logged in
Create the IF 1+1 protection
Difference when the
configuration of Hybrid
microwave is compared
Modify the NE ID
Set the RF parameters with the configuration of
traditional microwave
Add logical
boards Configure the Ethernet port
The three
Configure the Ethernet service procedures are
called
"configuring a
LAG.
Create a LAG
7-IFH2
7-IFH2 8-IFH2 5-IFH2
6-IFH2
5-IFH2
1+1 HSB
IDU 605 2F
Site B Site C
Site A
IFH2 IFH2
IFH2 IFH2
EMS6
In the two directions, the services are transmitted over Hybrid microwave.
board in slot 6.
3. Configure the EPL service from port 2 to port 3 on the EMS6 board.
4. Configure port 1 and port 2 into LAG_1, where port 2 functions as the main port and
Configure port 3 and port 4 into LAG_2, where port 3 functions as the main port and
7-IFH2
7-IFH2 8-IFH2 5-IFH2
6-IFH2 1+1
IDU 605 1F
Site A
5- Site D
IFH2 Site C
IFH2 IFH2
5-IFH2
IFH2 IFH2
EMS6
Site B
3. Configure the EPL service from port 2 to port 3, the EPL service from port 2 to
4. Configure port 1 and port 2 into LAG_1, where port 2 functions as the main port