Вы находитесь на странице: 1из 9

VSTPS Unit 11Warm Start Up on 12.09.

2017
Trip Date/Time 10th Sept2017 at 18:11Hrs

Capacity 500 MW

Reason of tripping/outage BTL

Time Till Start up 31Hrs

HP Casing Temp PI Tag showing straight line

Start Up Curve Warm Start-up (Turbine startup after 36Hrs)

Time taken As per Curve Actual

Light-up to synchronization 65mins 220mins

Syn. to 500 MW 100mins 255mins

Rolling Parameters

MS/HRH Pressure 100/12 80/-


MS/HRH Temperature 450/415 461/417
Oil Consumption(As per EEMG) 69 KL
VSTPS Unit 11Warm Start Up on 12.09.2017
Time
Activities Deviation / Remarks

Boiler light-up 01:30Hrs FG temp increased from 50 to 150 degree C in 59mins.


FG Temp. at APH I/L 226C, Hot SA temp 200C &
First Mill Cut-in 03:52Hrs Drum press 57ksc

Turbine Speed, HRH Pressure & HP Casing Temp PI Tag


Turbine Rolling 360rpm showing constant value.

Turbine Rolling 3000rpm

Unit synchronization 05:10Hrs


Total time taken from light-up to
475mins 500 MW
reach Full load/Stabilized load
Drum Level Drum level almost with in the limit.

Spray before Unit synchronization No

Steam Parameters Rolled at lower MS Pressure.

Chemical Parameters Boiler Water pH was almost with in the limit.

MDBFP Running 1Hr 45mins


VSTPS Unit11Warm Start Up on 12.09.2017
S.No. Startup deviations Reasons

1 Turbine rolled at lower MS Pressure.

2 Turbine Speed, HRH Pressure & HP Casing Temp PI


Tag showing constant value.
VSTPS Unit -11Warm Start Up on 12.09.2017

Drum Level HI + 250 mm

Coal flow

Load
Drum Level

Turbine Speed
SH Spray

1st Mill Cut in at 03:52hrs (FG Temp.


at APH I/L 226C hot SA temp 200C &
drum press 57ksc

Drum Level LO -375 mm


RH Spray
Unit sync
at 05:10hrs
VSTPS Unit 11 Start Up Steam Parameters

Actual
As per Curve

Load

Turbine Speed

HRH Pressure
VSTPS Unit 11Start Up Steam Temperatures
VSTPS Unit 11 Start Up FW Temperatures

FW Temp at Eco O/L is 30 degree C


more than Saturation Temp

Load

ECO O/L FW Temp


VSTPS Unit 11 Start Up Chemical Parameters

Boiler Water pH HI

Boiler Water pH
Boiler Water pH LO
Load

Вам также может понравиться