Installation Redline and


Quality Check Standard

www.huawei.com

HUAWEI TECHNOLOGIES CO., LTD. Huawei Confidential


CONTENT

Key Point
Check Antenna Installation
Check ODU Installation
Check IF Cable Installation
Check IDU Installation

HUAWEI TECHNOLOGIES CO., LTD. Huawei Confidential


Key Points
Caution Cause Requirement
1 Properly handle the IF board The field personnel do not know how This point must be imparted
and SCC power switches. to operate the power switches. As a to every field engineer,
result, a large number of boards on especially the personnel of
the existing network are damaged. the partners.

2 Do not reseat IF cables The ODU and IF board are damaged This point must be imparted
when the power is on. by the reseating of IF cables when to every field engineer,
the power is on. especially the personnel of
the partners.

3 Do not tear up the ODU seal If the seal of the ODU is torn up or This point must be imparted
or remove the ODU cover. the cover of the ODU is removed, the to every field engineer,
vendor will refuse to provide warranty especially the personnel of
services. the partners.

4 Do not damage equipment If the damage is caused by artificial This point must be imparted
with improper operations. factors, the vendor will refuse to to every field engineer,
provide warranty services. especially the personnel of
the partners.

HUAWEI TECHNOLOGIES CO., LTD. Huawei Confidential Page 3


Key Points

Properly handle the IF board and SCC power switches.

These boards are damaged due to


improper operations of the personnel.
Note: So many boards are found
damaged in only one project!

HUAWEI TECHNOLOGIES CO., LTD. Huawei Confidential Page 4


Key Points

Do not reseat IF cables when the power is on.

Ensure the power is off before reseating


IF cables or IF boards.
Pull IF cables out of the IF board, IF
jumper, or ODU or plug into them after
the power is off.
IF boards should also be reseated after
the power is off.
Be careful in the use of a multimeter for
testing the IF output voltage to avoid
short circuits.

HUAWEI TECHNOLOGIES CO., LTD. Huawei Confidential Page 5


Key Points

Do not reseat IF cables when the power is on.

Power off the IF board before reseating


IF cables.
Reseating IF cables when the power is on
tends to cause a short circuit between the -
48V power supply and the GND, which will
blow out the protection tube.
The picture shows the short circuit.

HUAWEI TECHNOLOGIES CO., LTD. Huawei Confidential Page 6


Key Points

Do not tear up the ODU seal or remove the ODU cover.

If the seal of the ODU is torn up or the


cover of the ODU is removed without
permission, the vendor will refuse to
provide warranty services.
The seal of the ODU shall not be torn
up.
The ODU cover shall not be removed
without permission.

HUAWEI TECHNOLOGIES CO., LTD. Huawei Confidential Page 7


Key Points
Do not damage equipment with improper operations.

If the damage is caused by artificial


factors, the vendor will refuse to provide
warranty services.
Handle ODUs with care.

Hoist and install ODUs with caution to


avoid collision with the tower.
If the damage is caused by artificial
factors, the vendor will refuse to provide
warranty services.
The ODUs damaged during engineering
operations must be returned as soon as
possible. The vendor shall not provide
warranty services after the warranty
expires.

HUAWEI TECHNOLOGIES CO., LTD. Huawei Confidential Page 8


CONTENT

Key Point
Check Antenna Installation
Check ODU Installation
Check IF Cable Installation
Check IDU Installation

HUAWEI TECHNOLOGIES CO., LTD. Huawei Confidential


Antenna Installation Check List

Check Item Result


1 The matter that is paint break off and distorted can not
appear on antenna. The antenna must be installed in the
right height and position and polarization according to
the design document or customer's instruction.
2 The fixation of antenna and pole are reliable, all screws
should be tightness. For the more than 1.2m antenna,
the side strut must be installed and fixed position is
correct.
3 Antenna identifier: The identifier of each antenna should
be labeled with opposite site name or ID.

HUAWEI TECHNOLOGIES CO., LTD. Huawei Confidential Page 10


Check Antenna Installation

The matter that is paint break off and


distorted can not appear on antenna.

The antenna must be installed in the


right height and position and polarization
according to the design document or
customer's instruction.

HUAWEI TECHNOLOGIES CO., LTD. Huawei Confidential Page 11


Check Antenna Installation
The fixation of antenna and pole are
reliable, all screws should be tightness.

Each screw should be


fastened well.

HUAWEI TECHNOLOGIES CO., LTD. Huawei Confidential Page 12


Check Antenna Installation
For the more than 1.2m antenna, the
side strut must be installed and fixed
position is correct.

1.Usually strengthening rod and hanging


bracket cannot locate at one side of antenna;
2.The height difference of two fixing points for
strengthening rod should be as small as
possible and the angle between strengthening
rod and horizon could not over 25.

HUAWEI TECHNOLOGIES CO., LTD. Huawei Confidential Page 13


Check Antenna Installation
Antenna identifier: The identifier of each
antenna should be labeled with opposite
site name or ID.

HUAWEI TECHNOLOGIES CO., LTD. Huawei Confidential Page 14


CONTENT

Key Point
Check Antenna Installation
Check ODU Installation
Check IF Cable Installation
Check IDU Installation

HUAWEI TECHNOLOGIES CO., LTD. Huawei Confidential


ODU Installation Check List

Check Item Result


1 ODU's and hybrid coupler's appearances are properly. The
latches of the ODU and hybrid coupler should tightly
engage on the antenna. The screws should be fastened
tight. The IF connector of ODU should be waterproofed and
face downward.
2 IF redundant: Leave enough slack when connecting cables
to the ODU to facilitate future maintenance.
3 ODU grounding: The ODU grounding cable should be
shortest length as possible and attached to the tower body
by the cable clamp. Before attached grounding cable, must
scrape-off the paint.

HUAWEI TECHNOLOGIES CO., LTD. Huawei Confidential Page 16


Check ODU Installation
The latches of the ODU and hybrid
coupler should tightly engage on the
antenna. The screws should be fastened
tight. The IF connector of ODU should be
waterproofed and face downward.

4 screws should be
fastened.

HUAWEI TECHNOLOGIES CO., LTD. Huawei Confidential Page 17


Check ODU Installation
Whether ODU is assembled with
Antenna directly or with Hybrid Coupler,
the IF connector of ODU must be down-
toward.

IF connector cant be up-toward.

IF connector must be down-toward. For 1+1, main and standby ODUs IF


connectors must be down-toward.

HUAWEI TECHNOLOGIES CO., LTD. Huawei Confidential Page 18


Check ODU Installation
For 1+1 HSB/FD application, hybrid
coupler top side which is attached
label, must be up-toward.

The hybrid coupler top side which is attached label,


must be up-toward.

HUAWEI TECHNOLOGIES CO., LTD. Huawei Confidential Page 19


CONTENT

Key Point
Check Antenna Installation
Check ODU Installation
Check IF Cable Installation
Check IDU Installation

HUAWEI TECHNOLOGIES CO., LTD. Huawei Confidential


Check IF Cable Installation
The ODU grounding cable should be
shortest length as possible and attached
to the tower body by the cable clamp.
Before attached grounding cable, must
scrape-off the paint.

The grounding cable of outdoor unit


should be soundly fastened to
grounding bar nearby.

HUAWEI TECHNOLOGIES CO., LTD. Huawei Confidential Page 21


IF Cable Installation Check List

Check Item Result


1 In general, the IF cable should be grounded to a minimum of
three points. When the IF cable is longer than 60 meters, add
a grounding point for every extra 50 meters. The place about
1 m away from the ODU and 1 m away from the cable entry
are propositional grounding point. All of outdoor connector
should be waterproofed.
2 Porthole: IF cable must be up-tilted or have Waterproof curve
in the entrance of porthole.
3 The IF cable route and position for the cabling should be
designed beforehand and arranged neatly. IF cable turns
should be smooth, and the bending radius should be larger
than 30 cm.
4 The connection between the jumper and the IF cable should
be connected in a correct and reliable way. If the connection
is at outdoor, waterproof the connection.

HUAWEI TECHNOLOGIES CO., LTD. Huawei Confidential Page 22


Check IF Cable Installation
In general, the IF cable should be The 3 grounding kits must
grounded to a minimum of three points. be mounted.
When the IF cable is longer than 60
meters, add a grounding point for every
extra 50 meters.
The place about 1 m away from the
ODU and 1 m away from the cable entry
are propositional grounding point.
All of outdoor connector should be
waterproofed.

1,2,3,4:IF Cable Grounding Point.

HUAWEI TECHNOLOGIES CO., LTD. Huawei Confidential Page 23


Check IF Cable Installation
The angle between IF cable and
grounding cable is the smaller the better.

The angle should <15.

HUAWEI TECHNOLOGIES CO., LTD. Huawei Confidential Page 24


Check IF Cable Installation
You should scrape the paint on the iron
before mounting the grounding kits.

HUAWEI TECHNOLOGIES CO., LTD. Huawei Confidential Page 25


Check IF Cable Installation
The grounding kit screw must be
fastened tightly.

HUAWEI TECHNOLOGIES CO., LTD. Huawei Confidential Page 26


Check IF Cable Installation
Porthole: IF cable must be up-tilted or
have Waterproof curve in the entrance of
porthole.
The IF cable route and position for the
cabling should be designed beforehand
and arranged neatly. IF cable turns
should be smooth, and the bending
radius should be larger than 30 cm.

HUAWEI TECHNOLOGIES CO., LTD. Huawei Confidential Page 27


Check IF Cable Installation
All of outdoor connector should be
waterproofed.

The ODU IF interface should be


waterproofed.

The area for grounding kit


should be waterproof.

HUAWEI TECHNOLOGIES CO., LTD. Huawei Confidential Page 28


Check IF Cable Installation
The operation of waterproof must be
regular.

Wrapping a layer of PVC Wrapping three layers of


tape. waterproof insulation tape.

Wrapping three layers of


PVC tape over the Using the outdoor bundling
waterproof insulation tape. strap to bind the PVC tape tight
HUAWEI TECHNOLOGIES CO.,ends.
at both LTD. Huawei Confidential Page 29
Check IF Cable Installation
The 2 ends of waterproof area should be
tied with cable tire.

The 2 ends arent The 2 ends arent


tired with cable tire. tired with cable tire.

The 2 ends are tired


with cable tire.
HUAWEI TECHNOLOGIES CO., LTD. Huawei Confidential Page 30
Check IF Cable Installation
The cable tire should keep a spare
length after cutting.

No spare long.

Reserve spare long.

HUAWEI TECHNOLOGIES CO., LTD. Huawei Confidential Page 31


Check IF Cable Installation
The IF cable and GND cable should be
tired with iron tower by cable tire.

HUAWEI TECHNOLOGIES CO., LTD. Huawei Confidential Page 32


Check IF Cable Installation
The reserved IF cables length outside or
indoor should be appropriate (5m),
otherwise, it will affect signal quality and
grounding.
The reserved IF cable should be
arranged tidily.

The IF cables should be lined up tidily


and neatly, and should be no obvious
breakage or distortion, and any exposed
copper is not allowed.
The bending radius of the IF cable
should be equal to or greater than
55mm.

HUAWEI TECHNOLOGIES CO., LTD. Huawei Confidential Page 33


Check IF Cable Installation
The IF cable/Feeder should be
tied/clamped on the vertical cable ladder
rung with 1m to 1.5m interval

<1.5m.

After the IF cable are installed, the


fixing ties with proper tightness and be
directed in the same way. All the root of
the ties should be totally cut off without
leaving any sharp ends.

HUAWEI TECHNOLOGIES CO., LTD. Huawei Confidential Page 34


Check IF Cable Installation
The holes for IF cable should be sealed.

HUAWEI TECHNOLOGIES CO., LTD. Huawei Confidential Page 35


Check IF Cable Installation
The main ODU of hybrid coupler must
connect with the main IF board.

For the assembled Antenna:


Right ODU: main;
Left ODU: Standby.
Standby 1 Main 1

IF cable temporal
Standby 1 Main 1 Label

HUAWEI TECHNOLOGIES CO., LTD. Huawei Confidential Page 36


CONTENT

Key Point
Check Antenna Installation
Check ODU Installation
Check IF Cable Installation
Check IDU Installation

HUAWEI TECHNOLOGIES CO., LTD. Huawei Confidential


IDU Installation Check List

Check Item Result


1 The installation position of IDU accords to the engineering
design document. The matter that is paint break off and scratch
and smear can not appear on IDU. Otherwise the equipment
must be repaint and cleaned.
2 There must be a space of 1 unit at the top and bottom of the
IDU chassis for heat dissipation. If there are multiple IDU, label
opposite site name or ID for each one.
3 Check Power Supply protection circuit breakers values accords
to the engineering design chart.

HUAWEI TECHNOLOGIES CO., LTD. Huawei Confidential Page 38


Check IDU Installation
The installation position of IDU accords
to the engineering design document. The
matter that is paint break off and scratch
and smear can not appear on IDU.
Otherwise the equipment must be repaint
and cleaned.

HUAWEI TECHNOLOGIES CO., LTD. Huawei Confidential Page 39


Check IDU Installation
There must be a space of 1 unit at the
top and bottom of the IDU chassis for
heat dissipation.

Height > 1U

HUAWEI TECHNOLOGIES CO., LTD. Huawei Confidential Page 40


Check IDU Installation
The matter that is paint break off and
scratch and smear can not appear on
Rack. Otherwise the equipment must be
repaint and cleaned.

HUAWEI TECHNOLOGIES CO., LTD. Huawei Confidential Page 41


Check IDU Installation
The cable running should clean and
tidily.

HUAWEI TECHNOLOGIES CO., LTD. Huawei Confidential Page 42


Check IDU Installation
The GND cable is the shorter the better.

HUAWEI TECHNOLOGIES CO., LTD. Huawei Confidential Page 43


Check IDU Installation
The cable running should clean and
tidily.

HUAWEI TECHNOLOGIES CO., LTD. Huawei Confidential Page 44


Check IDU Installation
The equipment room should be cleaned
every day.

1.The packages and boards of equipment


should not be left disorderly in the equipment
room.
2.No residue of the cut-off cable ties or any
other unnecessary articles should be left on
the floor.
3.Nothing unnecessary such as the residue
of the cutoff cable ties or bolts should not be
left in the cabinet.

HUAWEI TECHNOLOGIES CO., LTD. Huawei Confidential Page 45


Check IDU Installation
IF Jumper Label
The screws of board should be fastened
well.
Label for each cable should be clear
and tidily.

Trunk Cable Label

IDU Label

HUAWEI TECHNOLOGIES CO., LTD. Huawei Confidential Page 46


Check IDU Installation
Label for each cable should be clear Power Cable Label
and tidily.

DDF Label DCDB Label

HUAWEI TECHNOLOGIES CO., LTD. Huawei Confidential Page 47


Thank you
www.huawei.com