Вы находитесь на странице: 1из 9

BTS resources.

NSN 3G
Subunits

Subunits (SU) is a hardware part which compute


R99 traffic
(licensed by R99 Channel elements feature)
HSDPA traffic
(licensed by HSDPA processing set features)
HSUPA traffic
(licensed by HSUPA processing set feature)
CCCH traffic
(licensed by CCCH processing set feature)
FSMF system module

FSMF include 5.5 SU:


1.125 SU are dedicated for HSDPA
4.375 SU are dedicated for R99, HSUPA

1 SU compute 96 CE => 420 CE is maximum of WBTS capacity.


But it can be reduced.


1 SU 1 SU 1 SU 1 SU 1 SU
SU

4.375 SU for R99, HSUPA 1.125 SU for


Max CE capacity 420 CE (4.375 SU x 96 CE) HSDPA
FSMF system module

FSMF include 5.5 SU:


1.125 SU are dedicated for HSDPA
3.875 SU are dedicated for R99, HSUPA
plus (for example)
0.5 SU for 1 additional CCCH processing set due to increased cell range


1 SU 1 SU 1 SU 1 SU 1 SU
SU

0.5 SU for 3.875 SU for R99, HSUPA 1.125 SU for


add. CCCH CE capacity 372 CE (3.875 SU x 96 CE) HSDPA
Cell range
WCEL parameter which
blocks call attempts behind its value
reduce max available CE by means of
increasing usage of SU for CCCH processing

Allocation table

Cell range Max # of avail SU # SU for


of WBTS available CE for R99&HSUPA add. CCCH
Example:
0 CRange <192 km 420 4.38 0 WBTS 2/2/2, Cell range = 35 km for each
192 CRange < 224 km 372 3.88 0.5 carrier
224 CRange <256 km 324 3.38 1 Cell range of WBTS = (2+2+2)*35 km
= 210 km
256 CRange <288 km 276 2.88 1.5 Max available CE will be reduced to
288 CRange <320 km 228 2.38 2 372 CE
Routine troubles

Traffic 100% subunit 100% CE utilization


increasing (SU) utilization of HSUPA traffic

Block packet Decreasing of Shortage of CE


traffic attempts DCSR for HSUPA traffic

100% CE utilization Moving high speed HSPA data traffic


of R99 traffic to low speed R99 data traffic
Solution is increasing SU capacity
Submodule FBBA
adds 6 SU to FSMF capacity
maximum is 2 items


FSMF 1 SU 1 SU 1 SU 1 SU 1 SU
SU

FBBA 1 1 SU 1 SU 1 SU 1 SU 1 SU 1 SU

FBBA 2 1 SU 1 SU 1 SU 1 SU 1 SU 1 SU

2 FBBA: 16.375 SU for R99, HSUPA . Max CE capacity up to 1572 CE 1.125 SU for
1 FBBA: 10.375 SU for R99, HSUPA .Max CE capacity up to 996 CE HSDPA
Contacts

Evgeny Degtyarev
RAN engineer

https://linkedin.com/in/edegtyarev
mob.: +7 902 252 59 71 (GMT+2)
Relocation to Europe is welcome =)

Thank you for your attention!

https://linkedin.com/in/edegtyarev

Вам также может понравиться