Академический Документы
Профессиональный Документы
Культура Документы
Course Objectives
Nc
A
BTS PSTN
Mc
BSC
BTS
Inter-PLMN
Gb Nb
Iur-g
MGW GMGW
IuCs
NodeB
RNC IuPs
NodeB
SGSN GGSN
What does "i" stand for?
intelligent integration
intelligent identification of wireless integrates multi-interfaces
access intelligent error E1/STM-1/IP integrates multi
self-correction transmission supported
immensity intensify
large capability intensified design
supports 3072 TRX and 15000 Erl supports FR/EFR/HR/AMR/WB-AMR,
with only two racks innovative NetSpeed wireless
enhanced technology
IP
All-IP platform
supports IP bearer
ZXG10 iBSC Product Features
Based on V3 universal hardware platform
All IP hardware architecture
Large capacity and strong processing
capabilities
Modular design with good scalar
Separation of control streams from media
streams
Supporting Flex A and Flex Gb
Coding scheme: FR/HR/EFR/FR-ARM/HR-
AMR
Transmission interface: E1/T1/FE/STM-1
Easy and smooth upgrade
Flexible networking modes
High integration and low power consumption
Universal All IP Hardware Platform
Universal
Hardware Platform
Totally 16 boards
Smooth
All IP Upgrade
CDMA 2000 NGN Modularity
Modular Design
Boards
Different software can be used to define
different functions for the same board.
AIU, BIU, PCU and TCU are logical units; All
interface units are in the resource shelf.
Logical
No. Link Object Interface Type
Interface
1. A MSC STM-1, E1, FE/GE
Number
Abis Number of Interface Number of
Cabinet of Interface Capacity Interface Capacity
Interface Carriers Capacity Carriers
Carriers
A Single Abis:208 E1(T1) Abis:208 E1(T1) Abis:208 E1(T1)
1024 1024 1024
Cabinet A:188E1(T1) A:4 pairs of STM-1 A:1 pair of GE
E1(T1) Abis
Abis:624 E1(T1) Abis:624 E1(T1) Abis:624 E1(T1)
Dual Cabinets 3072 3072 3072
A:700E1(T1) A:11 pairs of STM-1 A:2 pairs of GE
Abis:3 pairs of
A Single Abis:3 pairs of STM-1 Abis:3 pairs of STM-1
1024 STM-1 1024 1024
Cabinet
A:188E1(T1) A:4 pairs of STM-1 A:1 pair of GE
STM_1 Abis
Abis:9 pairs of
Abis:9 pairs of STM-1 Abis:9 pairs of STM-1
Dual Cabinets 3072 STM-1 1024 3072
A:700E1(T1) A:11 pairs of STM-1 A:2 pairs of GE
Major Interfaces
Abis – IP over E1, E1, IP
A – TDM (E1, STM-1), IP
Gb – TDM (E1), IP
(Ater)
Boards
ZXG10 iBSC Shelves
Control Shelf (BCTC)
System control and management
(BGSN)
Resource Shelf Clock capture and distribution
(BPSN)
Switch Shelf
Switch Shelf (BPSN)
Large-capacity IP switch platform on the user plane
ZXG10 iBSC Boards
Shelf Board Full Name Functions
Universal Interface Module for
UIMC Level 2 switch of control plane signaling
Control plane
Control and management of CS and PS services, processing of
CMP Control Main Processor BSSAP and BSSGP protocols, and resource management of the
system
CHUB Control HUB Switch and convergence of control plane signaling
BCTC
Operation and maintenance, system control, management and
OMP Operation Main Processor
monitoring
SBCX X86 Single Board Computer O&M server
CLKG Clock Generation Clock generation and distribution
ICM Integrated Clock Module Clock generation and distribution (with GPS)
GLI Gigabit Line Interface Level 1 switch, interface with the resource shelf
BPSN Provides bi-directional user plane data switch with a capacity of 40
PSN Packet Switch Network
Gbps on each direction
Signaling processing, interface board (16 E1 lines for A/Gb,
SPB2 Signaling Processing Board
eight E1 lines for Abis)
Level 2 switch between the control plane and the user plane,
GUIM Giga bit User Interface Module
resource shelf management
GUP2 GSM Universal Processing Processing of user plane protocols, such as TC, PCU and RTP
BGSN
DTB Digital Trunk Board Provides 32 E1/T1 trunk interfaces
SDTB2 Sonet Digital Trunk Board 2 Provides two STM-1 interfaces
GIPI GE IP Interface Provides four FE interfaces or one GE interfaces for Abis/A/Gb
EIPI E1 IP Interface provides E1 or T1 based IP connection
Physical and Logical Boards of ZXG10 iBSC
Physical
Logical Board Functions
Board
Completes IP access over the Abis interface, and sever the control
IPBB
plane from the user plane
Completes IP access over the A interface, and sever the control
GIPI IPI
plane from the user plane (signaling from service)
Completes IP access over the Gb interface, and sever the control
IPGB
plane from the user plane
Search 20 ms TRU frames according to the channels and form IP
BIPB2 packets
For IP access over the Abis interface, it also processes RTP.
Rear Board
R R R R R R R R
R R
U U M M C C C C
S S
system clock, manages the V V
I I
M M
P
B
P
B
K K
G G
H
B
H
B
B B
2 3 1 2 1 2
control plane, and responsible
for the switch between the BCTC
Front Board
S S U U C C
Each iBSC must be configured C C
M M
C
M
C
M B B I I
O
M
O
M
I I
C C
H H
C C M M U U
P P P P P P M M
with one control shelf, which is X X C C B B
Rear Board
R R R R R
R R
S D S G G
D S
Processes universal services. P T P U
M
U
M
T P
B B B B B
1 2
Acts as the Level 2 switch
BGSN
center.
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17
The BGSN is configured in
Front Board
G S S G G G D E G S
D P U U
U P U I U P
Shelf 1 and Shelf 3 of the P B
T
B
B P I I
T
B P P B
2 2 2 2 M M I 2 2
main rack. When a single
shelf constitutes an office, it is
configured in Shelf 2.
No. Board Name Number Slot No. Backup
1 GUIM 2 9~10 1+1
2 GIPI - 1-8,11-17 1+1
3 GUP2 - 2-8,11-16 -
4 DTB 0-8 1-8,11-14,17 -
5 SDTB2 - 1-8,11-16 1+1
6 SPB2 - 1-8,11-17 -
7 EIPI - 1-8,11-17 -
BGSN Working Principles
The GUIM board is the
convergence and switch center for BPSN BCTC
various data in the resource shelf. It
completes the information exchange GLI CHUB ICM
between modules.
The GUIM board interconnects with
the GLI board in the packet switch BGSN
shelf to carry out level 1 switch GUP2 GUP2 GUIM
between different resource shelves.
DTBs and SPBs provide E1
interfaces, and SDTBs provide
STM-1 access.
GIPI boards provide FE and GE SDTB 2 DTB SPB2 GIPI
access.
Processes universal services STM-1 E1 E1 FE GE
(conversion from TC and TDM to IP
packets, processing of user plane
protocols).
Introduction to BPSN
Interconnects BGSNs and Packet Switching Shelf
user plane.
Rear Board
R R
U U
I I
Each iBSC should have one M M
2 3
BPSN, which is configured in
BPSN
Shelf 4.
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17
If the iBSC has two BGSNs,
Front Board
G U U
C C C C
then the BPSN is not G
L
G
L
G
L
G G
L L L
P
S
P
S M M M M I
M
I
M
I I I I I I N N P P P P
mandatory. However, this can C C
PWRD PWRD
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17
FAN FAN
G G R R R R
S G D D D G D D S S S G S R R R R R R G R R R
P U U U U D P P P U P S D D D D D U
G D S S S S
T T T T T
B P P I I T B B B P B P T T T T T
U T P P P P
B B B B B M M B M M
2 2 2 2 2 2 2 2 B B B B B B 1 B B B B B
2
R R
D G G D D G D D G G D G D D G G D R R R R R G G R R R R
U U U U U U U U D D D D D U U D D D D
T P P T P T
T P T T I I T P T T P T T T T T M M
T T T T
B 2
2 B B 2 B B M M B 2 B B 2 2 B B B B B B 1 2 B B B B
FAN FAN
R R
S G D D D G D D G G D S S G S R R R R R R R R R R
P U U U U P U P D D D D G G D
T P S D S S S
B P T T T P T T I I B B P B P T T T T T U U T P P P
B M M
2 2 B B B 2 B B M M 2 2 2 2 B B B B B B B B B B
1 2
R R
D G G D D G D D G G G D D G G D R R R R R G G R R R R
D D
U U U U U U U U D D D D D D D D
T P U U
P T T P T T I I T P T T P P T T T T T T
M M
T T T T
B 2
2 B B 2 B B M M B 2 B B 2 2 B B B B B B 1 2
B B B B
FAN FAN
Cabinet Configuration (2)
PWRD PWRD
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17
FAN FAN
G G R R R R
G G G G G G G G G G G R R
BIU U U U U U G G M M
I I U U I I U U G G
P P P P P P I I P P P E E U U I I
P P
2 2 M M M M N N
I I 2 2 2 I I 2 2 R R
AIU 1 2 C C
R R R R R R R R
C C C C S S U U O O I I C C R R
PCU B I I H H S S U U M M C C C C
M
P
M M M
P P P
B
C C M M M M C
C C P P M
C
M
U U V V I I P
M M
P K
G
K
G
H
B
H
B Abis Interface IP
TCU
X X B B B B 2 3 B B 1 2 1 2
FAN FAN
R R
G G G G G G G G G G G G G G R R R R R R
G G G G
I I U I I U U U U U I I U U G G G G
P P P I P P P E E U U E E
P P P I P P P E E
M M
I I 2 I I 2 M M 2 2 I I 2 2 R R R R R R
1 2
G G G G P P C C U U
I I
R R
U U
A-Interface IP
L L L L S S M M
M M I I
I I I I N N P P M M
C C 2 3
FAN FAN
PWRD PWRD
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17
FAN FAN
G G G G G G R R R
G G G R
I I U U U U U U G G G G
U
P P P P P I I P P E E U U
I 2 2 M M 2 2 R R M M
I 2
1 2
FAN FAN
FAN FAN
Cabinet Configuration (3)
PWRD PWRD
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17
FAN FAN
E D E G D G G SG S G R R R R
D D D S G G G R R R R R G G SR SR R
U U PI PI P U U D D D D U U PG G S
I
BIU P T T I T T U T
I B B U D P
I P P B P P P T T T T T M M BE E P
B B P B B P B 2 2
M M I I B
I I 2 / / 2 2 2 2 B B B B B 1 2 / R /
R B
AIU
R R R R R R R R
C C C C S S U U O I C C R R
PCU
M
P
M M M
P P P
B
C
B
C
I I
M M M
O
M
I
M M
H
C C U
H
U
S
V
S
V
U U M
I I P
M M
M
P
C
K
G
C
K
G
C
H
B
C
H
B
Abis Interface IPoE
TCU X X C C P P B B B B 2 3 B B 1 2 1 2
FAN FAN
G G G G G G R R R R R R R R
G G G G G G G G G
I I I I U U I I G G G G G G G G
U U U U U U U
P P P P I I P P E E E E U U E E
P P P P P P P
M M I I R R R R M M R
I I I I 2 2 2 2 2 2 2 R
1 2
G G G G G G P P C C U U R R A-Interface IP
I I U U
L L L L L L S S M M
M M I I
I I I I I I N N P P M M
C C 2 3
FAN FAN
PWRD PWRD
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17
FAN FAN
G G R R R
E D D E D D G D S S S G G G R R R R R G G
R R
U U P U U D D D D S S S
I T T I T T U T
I I B
P P U D U U P P
B B P P P T T T T T P
P B B P B B P B
M M 2 M M B
I I 2 2 2 2 2 2 B B B B B B B
1 2
E D D E D D G D G S S G G G R R
G R R R R R R R
P P U U U G G
I T T I T T U T U U D D D D D S S
I I B B P P P T U U P P
P B B P B B P B T T T T
M M
I I 2 M M 2 2 2 2 2 B B B B B B B
1 2
FAN FAN
FAN FAN
Contents
CP FE
functions of the
Back Board
RPU? Logic Unit
Power
Management
RS485,RS232 GPS485
PD 485
RS232
RS232
CPU Core RS485 DEBUG1- 232
1. Enables intranet addresses within the
BSC to communicate with each other. HD Disk
OMC1
Ethernet
2. Provides routes for the operation and CP FE
RS485
DEBUG 232
Logic Unit Clock Unit CPU DEBUG FE
Inner Bus
Back Board
CP FE, CP GE CLKIN
Ethernet
Switch Unit
CHUB
The CHUB works together with the UIMC/GUIM to be
responsible for control plane data stream exchange and
convergence in the system.
The control plane data from each shelf is sent to the
Ethernet switching unit of CHUB board through the
Ethernet cables on the control plane.
The data is then sent to UIMC board of the BCTC
through GE for level-2 switch, and then distributed to
each CMP board for processing.
CHUB
The RCHB1 board has three FE buses, on which FE interfaces are grouped as
FE1–8, FE9–16 and FE17–24.
The RCHB2 board has three FE buses, on which FE interfaces are grouped as
FE25–32, FE33–40 and FE41–46.
DEBUG FE/232
Logic Unit CPU
Inner Bus
Back Board
CP GE
Ethernet Ethernet
Switch Switch
Ethernet
Switch Unit
RS232
CPU
RS485
Inner Bus
SBCX
The SBCX board is the server board. It mounts the server
on the rack.
It provides the keyboard, the mouse and the VGA interface.
Uses Sossaman dual-path dual-core CPU with a frequency
of 2G Hz.
Supports multiple operating systems, including Windows
XP/2000/2003, Linux and Solaris.
Provides three FE interfaces, two GE interfaces and one
RS232 serial port.
Provides four universal USB interfaces.
Supports boot from hard disk and boot from USB drive.
SBCX
OMC1(eth3) is set to an external network address to communicate with
NetNumen M31 server.
OMP1(eth6) is set to an intranet address to communicate with the
OMP. VGA
USB
CPU Outside Mouse(MS)
Dual Core Interface
KeyBoard(KB)
OMC1
OMC2
Outside OMP1
Interface
RS232
USB
SAS HD1
SAS
Controller
SAS HD2
DTB
Provides 32 E1/T1 links for external connections.
Supports extraction of 8K synchronization clock from the
lines, which is transferred to the ICM board through the
cable as clock reference.
Supports 120/75 Ω impedance selection for E1 cables,
and supports coaxial cables and twisted-pair cables.
Supports 100 Ω twisted-pair T1 cables.
DTB
8KOUT/DEBUG-232
CP FE ,RS232,RS 485
CPU
Clock
Clock Unit
Back Board
Logic Unit
E1/T1 1~32
Circuit Switch HW
Interface Unit
Unit
DTP DIP Switches
S1
ON
S2
ON
S3
ON
S4
ON
S5
ON
ON S6
S7
ON ON
S8
ON S9
S10
ON ON
S11
S12
ON
X23
DTP DIP Switches
DIP Switch Configuration Default Location
Purpose
Switch Mode 1 2 3 4 1 2 3 4
SHORT
ON ON ON ON
Used for reporting the HAUL
S10 long/short wire status
ON ON ON ON
S11 of each E1 chip to the
CPU. LONG
OFF OFF OFF OFF
HAUL
RDTB Jumpers
On the RDTB, the E1 cable
works in the 75 Ω unbalanced
coaxial transmission mode by
default.
If the E1 line uses 120 Ω
balanced transmission mode,
the short-circuit block at X9–
X16 on the RDTB needs to be
removed.
The sending end is grounded
through the jumper. The
receiving end is connected to
a capacitor and then grounded
through the jumper. Jumpers
X9–X16 are used to complete
such settings.
RDTB Jumpers
X9-X16 Pin Connection Definitions
8KOUT/DEBUG-232
CP FE ,RS232,RS 485
CPU
Clock
Clock Unit
Back Board
Logic Unit
STM-1
Circuit Switch HW
Interface Unit
STM-1 Unit
SPB2
According to its functions, the SPB2 board can be classified into the
LAPD processing board (LAPD2), the signaling processing board
(SPB2) and the Gb interface processing board (GIPB2).
The LAPD2 board processes LAPD signaling. LAPD signaling data
from the BTS are received by the DTB/SPB/SPB2 board, and then
switched to the LAPD2 board through the circuit switching net on the
UIM board in the local resource shelf or the GUIM board in the local
Gigabit resource shelf. The LAPD2 completes the processing of
LAPD signaling data.
The SPB2 board processes MTP2 and X.25 protocols. It supports
extraction of 8 K synchronization clock from the lines, which is
transferred to the ICM board through the cable as clock reference.
The GIPB2 board processes the FR, NS and partial BSSGP protocols
for the GPRS, and provides Gb interfaces.
SPB2
CPU4-RS232
CPU 4
CPU3-RS232 CP FE
CPU 3
Ethernet
Switch Unit UP FE
CPU2-RS232
CPU 2
8KOUT/CPU1-RS232
CPU 1
Back Board
RS232,RS 485
Clock
Clock Unit
Logic Unit
E1/T1 1~16
Circuit Switch HW
Interface Unit
Unit
SPB2
Interface unit, which connects with the switching unit and
provides E1 interfaces.
Circuit switch unit, which implements the switching
between interface unit circuits and backplane circuits.
CPU, which implements signaling processing, board
management and internal connection control.
Ethernet Switch Unit, which implements control plane and
user plane data switch and provides FE interfaces.
Clock Unit, which extracts line clock signals and sends
them to the ICM board.
Each SPB2 board contains four CPUs.
Each SPBs board provides 16 E1/T1 interfaces.
GIPI
The GIPI board provides IP interfaces between iBSC and
the BTS, the SGSN and the MSC/MGW.
Implements Layer 3 protocol interface processing,
separates control plane data from user plane data, and
sends the data respectively to the Ethernet interfaces on
the internal control plane and user plane.
According to functions, GIPI can be classified into four
functional boards:
Abis interface Gigabit IP interface board(IPBB)
A interface Gigabit IP interface board IPAB(Signaling)
A interface Gigabit IP interface board IPI (signaling and service)
Gb interface Gigabit IP interface board(IPGB)
GIPI
The Interface Unit receives data and sends it to the service processing unit,
which separates user plane data from control plane data. User plane data is
then sent to the GUP2 through the user plane switch network, and control
plane data is sent to the CMP through the control plane switch network.
The GIPI board can choose RGER (providing one GE interface) or RMINIC
(providing four FE interfaces) as its rear board.
GE2
RS232 DEBUG1-232
Back Board
CPU Interface
Unit DEBUG2-232
Logic Unit
CP FE, UP GE
EIPI
The EIPI board provides E1 or T1 based IP connection and
works together with the DTB. It has no external interface
and no rear board. One EIPI works together with two DTBs
to provide up to 64 E1 or T1 ports.
EIPI
The interface unit receives HW data and sends it to the HPS daughter
card. The data is then processed according to the HDLC protocol and
then sent to the service processing unit. It sends user plane data
through the user plane switch network to the GUP2 for processing, and
sends control plane data through the control plane switch network to
the CMP for processing.
HW
HPS Subcard
Processing Unit
Interface
Back Board
Unit
RS232
CPU
Logic Unit
CP FE, UP GE, HW
GUIM
The GUIM performs Ethernet Level 2 switching between the control
plane and the user plane in the Gigabit resource shelf, the CS field
timeslot multiplexing slot switching and Gigabit resource shelf
management. It also provides external interfaces for the Gigabit
resource shelf.
It has the capability of 16 K circuit switching, and provides an internal
circuit switching network for the GE resource shelf.
It provides the clock drive in the resource shelf. It inputsPP2S, 8K
and 16M signals, which are sent to different slots in the resource
shelf after phase lockup to provide 16M, 8 K and PP2S clocks for
resource modules in this shelf.
The UGIM board performs Gigabit resource shelf management and
provides RS485 management interfaces in the Gigabit resource shelf;
It also provides board resetting and in-slot signal collection functions.
GUIM
Circuit
Switch Unit
HW
Inner Bus
RS485
DEBUG 232
Logic Unit Clock Unit CPU
Inner Bus
Back Board
CP FE
CLKIN
Switch Unit
CP FE 1~6
User Plane Control Plane
Switch Switch
GUP2
According to functions, GUP2 boards are classified into five functional
boards: Abis interface processing board BIPB2, A interface
processing board AIPB, user plane processing board UPPB2, dual
rate transfer board DRTB2 and Ater interface processing board TIPB2.
Over the STM-1 or E1 Abis interface, CS and PS services from the BTS
are switched to the BIPB2 board through the UIM board in the local
resource shelf or the GUIM board in the local Gigabit resource shelf. The
BIPB2 board searches 20ms TRU frames or PCU frames and form them
into IP packets, which are sent to the TCU or the UPU for processing.
Over the IP Abis interface, the BIPB2 board is also used to process RTP.
The DRTB2 implements code conversion, finishes TRAU frame conversion
and rate adaptation, and provides FR/EFR/HR/AMR/TFO function.
The AIPB board processes RTP and forms data into IP packets over the A
interface.
The UPPB2 processes user plane protocols such as BSSGP, PDCP and
GTP_U under the A/Gb mode.
GUP2
Each GUP2 board has 15 DSPs.
HW
DSP Unit
Back Board
DSP
CPU P UP GE
Ethernet
Switch Unit
…
DSP
P
CP FE
GUP2
CPU: responsible for board management, and provides
control plane FE interfaces for external connection.
DSP: processes universal services, including functions of
BIPB2, AIPB, DRTB2, UPPB2 and TIPB2.
Circuit Switch Unit: connects the serial ports of multiple-
chip DSP with the circuit switching network.
Ethernet Switch Unit: implements the Ethernet
connections for multiple-chip DSP and provides the user
plane FE interface for external devices.
Clock Unit: provides necessary clock signals for the units
on the board.
GLI
The GB Line Interface (GLI) board is located at level 1
switching subsystem of iBSC. It finishes physical layer
adaptation, IP package query, segmentation, forwarding,
and flow management functions, processes bi-directional
2.5Gbps forwarding, and implements the interfaces to
different resource shelves and external interface functions.
GLI
Interface Unit: provides GE optical interface and supports physical
backup. SD1–SD2, SD3–SD4, SD5–SD6 and SD7–SD8 are backup
groups.
Processing Unit: implements bi-directional IP packet table look-up,
fragmenting, forwarding and traffic management.
Queue Management Unit: implements bi-directional queue
management.
The GE optical interface receives user plane data from the GUIM and
sends it through the backplane to the PSN board for user plane data
exchange.
SD1~SD8 (GE Optical)
Optical&Ethernet Queue Management
Back Board
Processing Unit
Interface Unit Unit
CP FE
Logic Unit CPU
PSN
Provides bi-directional Inner bus
user plane data switch CP FE
CPU
with a capacity of 40
Gbps on each direction
The data from each GLI
Back Board
LVDS
board is sent to the Matrix
Switching Unit through
the high-speed serial
links on the backplane. It
is switched and then sent Logic Unit
to the destination GLI
board.
Matrix Switch Unit
Peripheral Monitor Unit (PMU)
Includes the PWRD board and the alarm box
PWRD is responsible for collecting some
peripheral and environment board information
within the cabinet, including the power distributor
and fan status as well as some environment
alarms like temperature/humidity, smog, water and
infrared alarms. Each cabinet has one PWRD
board.
The Alarm Box (ALB) can report system alarms at
different levels according to system fault grades to
facilitate timely interference and handling by
equipment management personnel.
Board Summary 1
Board Summary 2
Board Summary 3
Control Plane and User Plane Interconnection
BPSN BCTC
SBCX
PSN UIMC UIMC OMP HUB
BGSN BGSN
GUIM GUIM
UIMU( UIM_2) UIMU( UIM_2)
User Control User Control
Circuit Circuit
plane plane plane plane
DTB
GUP2 SPB2 GUP2 GIPI
SDTB2
E1 STM-1 IP
Control Plane
CHUB UIMC
User Plane
CHUB UIMC
CMPU
UPU
Access Switch
TC Unit
BTS Unit Unit
O& M Unit
MSC PMU
Pow er a nd Fa ns
SGSN
iBSC External Physical Interfaces
FE
E1
MSC/ MGW SGSN
STM -- 1
A Gb
iBSC
Abis Ater
E1 Abis
E1 borne TDM link
IP Abis
FE/GE borne IP link
IPoE Abis
E1 borne IP link
BIU - E1 Abis
The interface board can be the DTB or SDTB2 board. The access
capacity of SDTB2 is four times that of the DTB.
E 1 Abis
to TCU or UPU
BIPB2
BIU
User Plane
GUP2
Switching
1 Network
GUIM
DTB
2
T to CMP
32
SPB2
LAPD2
Internal
E1/ T1 Ethernet HW
BIU - IP Abis
IP Abis
BIU
IPBB BIPB2
TCU
GUP2
GIPI
GUP2
UDP
User Plane
Switching
SCTP
Network
GUP2
to CMP UPU
External Internal
Ethernet Ethernet HW
BIU - IPoE Abis
IPoE Abis
BIU
BIPB2
1 TCU
2
GUP2
DTB
EIPI
RTP RTP
GUP2
32
c UDP c UDP
ML/MC -PPP
PPP UDP
HDLC
User Plane
SCTP Switching
IP Network
GUP2
UDP
to CMP
UPU
Control Plane Switching Network
Internal
E1/T1 Ethernet HW
Access Unit- A Interface Unit (AIU)
E1 A
E1 borne TDM link
IP A
FE/GE borne IP link
AIU - E1 A
E 1A
AIU
1
TCU 2
DTB
User Plane 32
GUP2
GUIM
Switching
Network
1
SPB2
2
16
Control Plane Switching Network MTP2
Internal
E1/ T1 Ethernet HW STM -1
AIU - IP A
IP A
AIU
IPI AIPB
GUP2
GIPI
RTP RTP
UDP UDP
BIPB2
GUP2
Switching
SCTP Network
to CMP
External Internal
Ethernet Ethernet HW
Access Unit–Gb Interface Unit (GIU)
E1 Gb
E1 borne TDM link
IP Gb
FE/GE borne IP link
GIU - E1 Gb
E 1 Gb
UPPB2 GIU
GUP2
1
SPB2
2
User Plane 16
Switching
UDP
Network 1
SPB2
2
16
Control Plane Switching Network
to CMP
Internal
E1/ T1 Ethernet
GIU - IP Gb
IP Gb
GIU
IPGB UPPB 2
GUP2
GIPI
UDP UDP
BIPB 2
GUP2
Switching
Network
to CMP
Control Plane Switching Network
External Internal
Ethernet Ethernet HW
O&M Unit
OMP Board
System operation and maintenance;
Connects to the iOMCR;
System management and monitoring
Switching Unit
OMPP
HH
OMP UU LMT -R
OMP
BB
SBCX
SVB
100 M Ethernet
Operation and Maintenance Networking
The networking mode of SBCX is as follows: iBSC and
SBCX(OMP1) form a subnetwork, and
SBCX(OMC1)+NetNumen for a subnetwork. The local
OMM usually consists of the SBCX and the SBCX client
(LMT).Usually, LMT and the OMM client are installed on
the same PC. The PC is then put in a different equipment
room. The network interfaces of SBCX are connected to
the switches of each iBSC, and then connected to the
router. Then the cables are connected to the remote
NetNument using WAN connection.
When the iBSC needs to manage SDR BTSs, the OMCB
server manages all SDR configurations (physical,
transmission and radio configurations), links, alarms and
versions. The OMCB program is installed on the SBCX
and a pair of GIPI boards must be configured.
Operation and Maintenance Networking
Processing Units & Monitoring Units
2*GE FE
nd nd
2 Switch Subsystem 2 Switch Subsystem
GE
FE
BGSN 1 BGSN N
IP Switch Unit (PSU)
If there are only two resource shelves, the Level-1 switch subsystem is
not needed on the user plane. The two resource shelves can be
directly interconnected using Gigabit optical interfaces.
Control
nd
2 Switch Subsystem
FE
nd nd
2 Switch Subsystem 2 Switch Subsystem
2*GE
GE
FE
BGSN 1 BGSN 2
Contents
Gb Interface
Control plane GIU
switch network
CMP OMP
User Plane Signal Flow in the PS Domain
The BIU severs CPU frames from all frames and sends them to the
UPU(UPPB2) through the user plane switching network. The UPU then
separates PS field user plane data from CPU frames received for
further processing. After data processing is complete, the data is sent
to the GUI through the user plane switching network.
UPU TCU
CMP OMP
Control Plane Signal Flow in the CS Domain
Abis interface signal flow Abis interface unit (BIU) sends signaling in the
LAPD channel to the CMP board as control plane data. The CMP
processes such data and sends some of it directly back to the BIU (flow
direction: 1→1). Some signaling data will be sent to the AIU in the form of
A-interface signaling flow (flow direction: 1→2).
A-interface signal flow: The AIU processes the MTP2 part of A-interface
signaling, and then sends it to the CMP to complete the processing of
MTP3 and layers above. Some global processes need the participation
of the OMP. The data flow direction is 2→3→3→2 or 2→2.
UPU TCU
Gb Interface
1 Control plane GIU
Switching network
CMP OMP
Control Plane Signal Flow in the PS Domain
For some control plane signaling in the PS field, the system requests
resources from the CMP board, and then sends the signaling to the
UPPB2 for processing.
When the MS is processing PS services, control plane signaling should
be separated from UPPB2 and then sent to the CMP for processing.
UPU TCU
CMP OMP
Control Plane Signal Flow in the PS Domain
Abis interface signaling flow
The Abis interface unit (BIU) sends control plane data in
the LAPD channel to the CMP board. The CMP
processes such data and sends some of it directly back
to the BIU (flow direction: 1→1). Some data, such as
packet assignment messages, is sent to the UPU,
which processes the data and then sends it to the BIU
through the user plane switch network (flow direction:
1→3→2).
Data from the Abis interface unit is sent to the UPU
through the user plane switch network. The UPU
processes the data and separates control signaling
packets, which are sent to the control plane processing
board (CMP).The data flow direction is: 2→3→3→2.
Control Plane Signal Flow in the PS Domain
Gb interface signaling flow
The GIU sends BVC channel data as control plane data to the
active CMP. The CMP processes the data and sends some of it
(such as PTP BVC restart) to other CMPs and some (such as
signaling BVC restart) to the OMP. The CMP or the OMP
processes the data and some signaling generates the Abis
signaling traffic, such as paging messages in the PS or CS field,
whose data flow is 5→1 or 5→3→2; other signaling, such as PTP
BVC restart acknowledgement and signaling BVC restart
acknowledgement, is sent to the Gb interface through the GUI, with
the data flow as 5→5 or 6→6.
The GUI routes data from other BVC channels to the user plane
processing unit, which separates control plane data and sends it to
the CMP. The CMP processes the data and some signaling, such
as PTP paging messages, is sent to the Gb interface through the
GIU with the data flow as 4→3→5; some signaling generates the
Abis signaling flow, such as location messages, with the data flow
as 4→3→1.
User Plane Board Signal Flow in the CS Domain
E1 Abis, E1 A
E1 Abis E1 A
A iOMCR Client
Control Plane Board Signal Flow in the CS Domain
E1 Abis, E1 A
E1 Abis E1 A
iOMCR Client
User Plane Board Signal Flow in the CS Domain
IP Abis, IP A
BPSN BCTC
The BIU severs user SBCX
plane data from control PSN UIMC UIMC OMP HUB
plane data, and then
sends user plane data
CMP
to the TCU, which GLI GLI CHUB
AIU. GUIM
UIMU ( UIM _ 2 )
GUIM
UIMU ( UIM _ 2 )
IP Abis IP A
iOMCR Client
Control Plane Board Signal Flow in the CS Domain
IP Abis, IP A
BPSN BCTC
The Abis interface unit SBCX
(BIU) sends signaling in PSN UIMC UIMC OMP HUB
the LAPD channel to the
CMP board as control
plane data. The CMP GLI GLI CHUB CMP
IP Abis IP A
iOMCR Client
User Plane Board Signal Flow in the PS Domain
E1 Abis, E1 Gb
BPSN BCTC
The BIU severs CPU SBCX
frames from all frames PSN UIMC UIMC OMP HUB
and sends them to the
UPU(UPPB) through the
user plane switching GLI GLI CHUB CMP
some signaling
generates the Abis BGSN BGSN
signaling flow, such as GUIM GUIM
UIMU ( UIM _ 2 ) UIMU ( UIM _ 2 )
paging messages in the
UP CP Circuit UP CP Circuit
CS field
Signal flow 5→3→2.
BIPB2 LAPD2 DTB UPPB2 GIPB2
E1 Abis E1 Gb
iOMCR Client
User Plane Board Signal Flow in the PS Domain
IP Abis, IP Gb
some signaling
generates the Abis BGSN BGSN
PS or CS field
Signal flow 5→3→2.
BIPB2 IPBB UPPB2 IPGB
IP Abis IP Gb
iOMCR Client
IP over E1 Signal Flow
IPoE User Plane Signal Flow IPoE Control Plane Signal Flow
BGSN BGSN
GUIM GUIM
UIMU ( UIM _ 2 ) UIMU ( UIM _ 2 )
UP CP Circuit UP CP Circuit
OMP OMC-R
P I S G D G S G C C G P U
W C P I T U D U M H L S I
R M B P B P T I P U I N M
D I B M B C
RS485 Ethernet
Internal Communications Management
BPSN BCTC in 1# Rack
UIMC OMP
485 Signal
GLI UIMC CHUB CLKG
PWRD
in Each
User
Control Rack
Plane GUIM
Ethernet Plane CLKG
Ethernet
BGSN1
User Plane Ethernet UIMC
GUIM
Circuit Switch
BGSN2 Shelf
System Clock Capture and Distribution Principles
board
DTB, SDTB2 and SPB2 can be DTB EIPI GIPI GLI GLI
used to extract line reference
The BPSN does not need a clock
reference
Intra-shelf Cable Connection
Clock extraction and distribution cables;
Control plane and Ethernet interconnection cables;
User plane optical cable connection;
Monitoring cable.
Clock Extraction and Distribution Cables
The clock extraction cable
connects the 8KOUT Power distribution subrack
interface on the DTB rear Fan subrack
board to the 8KIN interface G
on the ICM. BGSN
U
I
M
The ICM can also extract
U O I C
GPS signals as the clock BCTC I M C H
M U
reference. C P M
B
each shelf.
Control Plane and Ethernet Interconnection Cables
access status. G
U
I
BPSN L
M
The PWRD board reports I
C