Академический Документы
Профессиональный Документы
Культура Документы
XTR
pressure, flow
XTR – 2-wire transmitter
Transmit control 2-Wire
XTR112
signals from a °T
control station
out to a remote
device.
– Valve, actuator, heater
– 3-wire transmitter
4-20mA Overview
0 to 100% 4 to 20mA
Signal Signal
Receiver
Sensor Transmitter 1V to 5V
250Ω
T
Why Is Signal Conditioning Required?
• Linearity errors on most
Bridge
sensors creates an
unacceptable error.
Output
Ideal
Output
1.2
Linearity (%)
1
0.8
0.6
0.4
0.2
0
0 200 400 -50 50 100
Temperature (°C)
Temperature (°C)
Transmitter Type Diagrams
> 1000 feet
50-60 Hz
Noise +8 V to +40V
+24 V typical
+VS VLOOP
2-Wire Transmitter XTR -
I OUT 4-20mA RL VOUT
250typ 1V-5 V typ
>1000 feet
50 - 60 Hz
+7V to +44V
Noise
+24V Typical
IOUT 4-20mA +
3-Wire Transmitter +VS XTR RL VOUT
250typ 1V-5V typ
-
2-Wire vs. 3-Wire Transmitter
• Application-specific parameters determine which
transmitter type should be used
– Accessibility and location
– System power requirements
– Sensor input or voltage/current input
2-Wire vs. 3-Wire Transmitter
• 2-Wire Transmitter (Loop powered)
– Transmitter and sensor remotely located
– Local power supply not practical
– Input circuitry floats with respect to loop supply ground
• 2-Wire Transmitter
RL
– Submersible temperature sensor
– Remote location prevents local
3-Wire
XTR111
power supply
– Sends data back to control
XTR
station
XTR
2-Wire
XTR112
• 3-Wire Transmitter
°T – Sends control signal to element
at remote location
– Local power supply is available
2-Wire Transmitters
2-Wire Typical Input Scaling
• 4-20mA span is 16mA XTR117
Current
100
125kΩ
40uA
– Input span is 160µA
IIN +
IIN
• Offset current needed if 0 to 160μA
2
- A1
R1
2.475 kΩ
IO = 100 * IIN
2-Wire Typical Input Interface
VREG XTR117
8
IIN
IOUT DAC
2
REF3140
VREG XTR117
8
IRET
3
Input IIN
Circuitry 2
VREG XTR117
8
IRET
3
IIN
VOUT DAC
2
IRET
3
Typical 2-Wire Transmitter
• IRET is not GND
XTR117 +5V
•
VREG V+
Current Input Regulator
B
• Current Output 1kΩ
E
• Regulator and input RLIM
100Ω
circuitry floats at IRET IRET
potential R1 R2
2.475 kΩ 25Ω
IO
2-Wire Transmitter Common Abuse
RIn
IIN
V+
VLoop
VIn XTR117
IOUT
IRET RL
Grounded Loop Supply with
Floating Input Source
XTR117
5V Regulator
R3 125k
40uA V1 25
5
3
+ + 1
R7 250
IIN 160u - 2
4
A I LOOP 20mA
R1 2.475k
R4 100
R2 25
+
Internal Current Paths
XTR117
5V Regulator
IOFFSET
R3 125k
40uA V1 25
5
+ 1
3 +
R7 250
2.475k
IIN 160u - 2
R1 4
R3 125k
40uA
Virtual Short
5
+
+ 3 + 1
R1
I IN 160u - 2
- 4
Equal
+ R 4 100
R2
VR1 = VR2
-
IR1 200uA IR2 19.8mA
I LOOP 20m
Calculating IRET Level
XTR117 XTR117
5V Regulator 5V Regulator
R3 125k
R3 125k
40uA V1 25 40uA V1 25
5 5
+ +
RL 250
3 + 1 3 + 1
RL 250
2.475k 2.475k
I IN 160u - 2 - 2
R1 4 I IN 0 R1 4
IRET IRET
R2 25
R2 25
R4 100 R4 100
R3 125k
R3 125k
VLoop VLOOP
25V 25V
5 5
+ + 1
3 + 1 3 +
R7 250
R7 250
2.475k 2.475k
I IN - 2 I IN - 2
160u R1 4 160u R1 4
R2 25
R2 25
V IRET 0V
V IRET 5.495V
V Float 5V V Float 4.45mV
IR1 200uA IR2 19.8mA IR1 196.08uA IR2
ILOOP 20mA -178.25uA ILOOP 17.82uA
+
EF
REG
S
• Voltage Input -
Current
Mirror IS
+
• Current Output 3V ISET
-
• Current gain set by VIN VIN
+
VG
and RSET -
A1
VSP
+5V
XTR111 OD
REG F EF
470nF
2kΩ
Short-Circuit
Current Protection
+
REG S Mirror IS
REF3140
3kΩ +
- 15Ω
3V ISET
- Q1
μC VG
+
VOUT DAC
VIN Q2
A1
-
10nF
GND 15Ω
RSET 2kΩ
LOAD
4-20mA Product Family
XTR101 I_IN to I_OUT Converter, Current Excitation
XTR115 I_IN to I_OUT Converter, 5V Regulator, 2.5V Reference
2-Wire General Purpose
XTR116 I_IN to I_OUT Converter, 5V Regulator, 4.096V Reference
3-Wire General Purpose XTR111 Configurable Input/Output Ranges, Voltage to Current Converter