Introduction to IP LDK-100/300/300E

Digital Key Telephone System

1. System Introduction
2. New Board Description
1. System Introduction
System Overall Configuration

LCOB
VMIB (Voice Announcement Service)

LCOB
LDK-50/100 MB Iss: Rev:

PSTN LCO WTIB


ED 3667 STIB : So RF Base
DECT

LCOB
VoIP DTIB

LCOB
IP

MPB
SLIB
LDK-50/100 MB Iss: Rev:

E1 RS232C G4 Fax
ED 3667 ISDN Phone
PRI
ISDN Video Phone
BRI Printer
Voice PFTU Battery
(ISDN Based)
Voice Mail
Networking(PRI) Ext MOH Billing/PMS Voice
Ext. Paging DKTU SLT

LAN:10M Ethernet
PC Admin Mail
Loud Bell
(Relay)

Remote Services Gateway

PSTN
Internet

PC PC PC CTI/TAPI Billing Voice


Attendant Phone Admin Server /PMS Mail
DKTU SLT PC

WAN
WAN Data Network area
Voice Router Hub (10/100M)
Networking (VoIP)

IP Phone

1/16
1. System Introduction
System Components

CO/Extension Boards
LDK-300/300E
-. LCOB : Analog CO. Interface B/D (4 ports)
-. PRIB : ISDN PRI Board (30 channels)
-. BRIB/BRIBE : ISDN BRI Board (8 channels)
KSU -. STIB/STIBE : ISDN S/T Interface (8 channels)
-. DTIB : Digital KTU Interface B/D(12,24 ports)
-. SLIB24/48 : Single Line Tel Interface B/D(6 ports)
-. KSU : Key Service Unit -. DSIB : 6 Digital KTU and 6 SLT Interface B/D(12 ports)
-. MPB : Main Processor Board -. SLIBII : Single Line Tel Interface B/D(12 ports)
-. MPBE for IP LDK-300E -. WTIB : DECT Interface B/D (4Cell +Opt 4Cell)
-. WTIU : DECT option B/D (4 Cell )
-. PSU : 350W, 250W -. SLIB2E : 12 port SLT Interface B/D
-. PSU-D : 320W -. VOIB/VOIBE : VOIP Interface B/D(8 chs/24 chs)
-. Universal Slot : 9 EA -. CLCOB4/8 : 4/8 ports CO Interface B/D with CID function
-. VMIB/VMIBE : Voice Mail I/F B/D (8 chs, max.10Hr)

Optional boards
-. DTRU : DTMF Receiver Unit(2 chs)
-. CMU : Call Metering Unit(16KHz,12PR,50PR)
-. RGU5 : Ring Generator Unit(External)
-. PFTU : Power Failure Transfer Unit (6 circuits)
-. DTRUII : DTMF Receiver Unit (4 chs)
Terminal -. CPTU A/B : Call Progress Tone detection Unit (2 chs)
-. MODU : Modem Unit (33.6kbps)
-. RGU : Ring Generator Unit ( Int 25Hz)
-. Digital KTU : -. DTRU4 : DTMF receiver unit ( 4 chs)
KD/E, LKD, LDP-7000 Series -. RAU : Relay Alarm Unit
DSS, Phone Box -. CPTU4 : Call Progress Tone detection Unit (4 chs)
-. CMU4 : Call Metering Unit (4 chs)
-. SLT, Fax, Modem -. VOIU/VOIUE : VOIP Interface Unit (2 chs/12 chs)
-. Wireless Terminal -. RPTU : RePeaTer unit for DKTU
GDC-330H,335H,345H -. SDMU32/SDMU_A : SDRAM module
-. CIDU4/8 : Caller ID unit(4/8 chs)-DTMF/FSK Type
-. VCEU/VCEUE : Voice Channel Expansion Unit (4 chs)
-. FMEU2 : Flash Memory Expansion Unit (5 hours)

2/16
1. System Introduction
System Components

LDK-100 CO/Extension Boards

KSU All kinds of CO & Extension card used in LDK-300

-. KSU : Key Service Unit [LDK-100 Only]


-. MPB : Main Processor Board BRIBE : 2 Basic Rate Interface
-. PSU : 120W BRIUE : 2 Basic Rate Interface
-. PSU-D : 320W NPRIB : 1 Primary Rate Interface
-. Universal Slot : 6 EA

Optional boards

Terminal All kinds of option boards used in LDK-300

-. Digital KTU : [LDK-100 Only]


KD/E, LKD, LDP-7000 Series SIU :1 Serial port
DSS, Phone Box LANU : 10 Base-T Ethernet port
-. SLT, Fax, Modem, TAD SMEMU : 2Mbytes SRAM Expansion
-. Wireless Terminal: DMEMU : Software Download
GDC-330H,335H,345H PLLU : for ISDN Board

3/16
1. System Introduction
System Max. Call Capacity

-. Medium / Large Size Digital KTS


-. Maximum Capacity
Max. Port (Number of Boards)
Extension Network Side
SYSTEM KSU
So DKTU SLT PRI BRI LCO
(STIB) (DTIB24) (SLIB II) (PRIB) (BRIB) (LCOB8)
1st KSU 48(2) 48(4)
LDK-100 40(5) 40(2) 40(5) 40(5)
1st KSU+2nd 96(4) 96(8)
1st KSU 56(7) 96(4) 96(8) 120(4) 56(7) 64(8)
LDK-300 1st KSU+2nd 112(14) 192(8) 192(16) 180(6) 112(14) 128(16)
1st KSU+2nd+3rd 152(19) 288(12) 288(24) 180(6) 152(19) 192(24)
1st KSU+2nd+3rd+4th 384(16) 384(32) 256(32)
LDK-300E 1st KSU+2nd+3rd+4th+5th 152(19) 396(17) 480(40) 180(6) 152(19) 320(40)
1st KSU+2nd+3rd+4th+5th+6th 396(17) 576(48) 384(48)

-. VMIB
LDK-100 : Max. 16 Channels, 20 Hours(2)
LDK-300/300E : Max. 24 Channels, 30 Hours(3)
-. WTIB
LDK-100 : Max 16 Cells(2)
LDK-300/300E : Max 24 Cells(3)

4/16
1. System Introduction
System Resources & Capacity

Capacity
Description
LDK-100 LDK-300 LDK-300E
1st KSU 144 144
144
Time Slots 2nd KSU 144 144
3rd KSU 96 96
KSU 2 3 6
Serial Port(RS-232C) 2(MPBE:1, SIU:1) 4(MPB:2, MISB:2) 4(MPB:2, MISB:2)
Alarm/Door Bell Input 2(MPBE:1, MISB:1) 3(RAU:2, MISB:1) 3(RAU:2, MISB:1)
External Control Contact 6(MPBE:2, MISB:4) 7(RAU:3, MISB:4) 7(RAU:3, MISB:4)
Music Source Inputs 3(MPBE:1, MISB:2) 3(MPB:1, MISB:2) 3(LMUE:1, MISB:2)
DTMF Receivers 32 80 112(Master:80, Expansion:32)
Power Fail Circuit 40 90(30/KSU) 180(30/KSU)
Intercom Group 5 15 15
External 3(MPBE:1, MISB:2) 3(MPB:1, MISB:2) 3(LMUE:1, MISB:2)
Paging Zone
Internal 15 35 35
System Speed Dial 1500(24Digits) 3000(24Digits) 5000(24Digits)
Station Speed Dial 100(24Digits) Per Station 100(24Digits) Per Station 100(24Digits) Per Station
Last Number Redial 10 10 10
Save Number Redial 1 1 1
DSS/DLS Console 3 7 7
SMDR 2000 5000 10000
CO Line Group 24 72 72
Hunt/UCD Group 15 48 48

5/16
2. New Board Description

New Board/Unit

Board Unit
CLCOB 4/8 CIDU 4/8
VOIBE VOIUE
VMIBE / AAIBE VCEUE
MPBE PMUE
LMUE
PSU-D

6/16
2. New Board Description
CLCOB4/8
Description
•CLCOB4 provides 4 Loop start CO line interface.
•CLCOB8 provides 8 Loop start CO line interface.
•CLCOB4/8 can be installed on the universal slot No.1-9 of any KSU.
•Maximum 200 analog lines limit Analog CO interface ports.
•Pulse Dial function is not applicable in CLCOB8.
•CLCOB4/8 are implemented to accommodate CIDU4/8 option board.
•Add-on boards :
-.CLCOB4 : DTRU4, CPTU4-C, CIDU4(CID + CMU-50PR)
-.CLCOB8 : DTRU4, CPTU4-C, CIDU8(CIDU + CMU-50PR)
Switching Functions
SW Function Remark
Mode selection switch
SW1 ON : Country mode 1), 2)
OFF : CTR21 mode
Upper Side – Normal Operation(short loop)
SW2 3), 4)
Lower – Service Position(long loop)

LED Indications-CLCOB4/8
LED Function Remark
LED1 The status of line 1, ON: in use, Green CLCOB4/8
LED2 The status of line 1, ON: in use, Green CLCOB4/8
LED3 The status of line 1, ON: in use, Green CLCOB4/8
LED4 The status of line 1, ON: in use, Green CLCOB4/8
LED5 The status of line 1, ON: in use, Green CLCOB8
LED6 The status of line 1, ON: in use, Green CLCOB8
LED7 The status of line 1, ON: in use, Green CLCOB8
LED8 The status of line 1, ON: in use, Green CLCOB8

7/16
2. New Board Description
CIDU4/8

Description
•There are two types of CIDU4/8, FSK-CIDU4/8 and DTMF-CIDU4/8.
•FSK/DTMF CIDU4/8 detects Caller ID signal that are supplied from the CO line interface.
•FSK/DTMF CIDU4/8 interface contains Microprocessor, CID Unit in the Memory,
Call Metering Unit (CMU-50PR).
•FSK/DTMF CIDU4/8 is used as an Option Board in CLCOB4/8 and cannot be used alone.
•Only when CIDU4/8 is inserted to CLOB4/8, the MPB recognizes CLOB4/8 board
as IPP board.
•FSK-CIDU4/8 enables CID function in case of On-hook(Type I) and Off-hook(Type II).
•DTMF-CIDU4/8 enables only for On-hook(Type I).

Switching Function
Switch Function Remark
SW1 CIDU Reset button

LED Indications
LED Function Remark
LED1 Flickering : CIDU in use (Green)
LED2 Reserved

8/16
2. New Board Description
VOIBE/VOIUE
Description
•The VOIBE/VOIUE card can be installed in LDK-300 and LDK-100.
•Its main job is to provide the Ethernet interface for S/W applications and VOIP feature with
optional VOIUE daughter.
•VOIB is installed on the universal slot No. 1-9 of KSU except the slot No. 9 of 1st KSU.
•The number of ports are expanded to 24 channel comparing with the existing VOIB.
•VOIBE has twelve(12) ports basically and VOIUE has additional twelve(12)
ports.
Switching Functions
Switch Number Functions Remark
SW 1 Hardware Reset Switch for CPU(S32500C)
SW 2 Watch dog enable Switch Default : Off
Pole 1 Reserved
Pole 2 Boot Mode(Off), Application Mode(On) Default : On
SW 4
Pole 3 Reserved
Pole 4 Reserved

LED Indications
LED Number Functions Remark
LD 1 to LD 4 Channel Status LED (ON : Busy, Off : Idle)
LD5 VOIBE DSP Status (ON : Busy, Off: idle)
LD6 VOIUE DSP Status (ON : Busy, Off: idle)
LD7 to LD8 Reserved
LD9 Operation
Collision Status LED
LD12,LD16
(ON : Collision, OFF : Normal operation)
Full-Duplex Status LED
LD11,LD15
(ON : Half-Duplex, OFF : Full-Duplex)
Speed Status LED Seen in
LD13,LD17
(ON : 100Mbps operation, OFF : 10Mbps) MJ1, MJ2
Link Status LED Seen in
LD10,LD14
(ON : Link OK, OFF : No Link) MJ1, MJ2

9/16
2. New Board Description
VMIBE/AAIBE
Description
•VMIBE/AAIBE provides system announcement, ACD/UCD announcement, and User Greeting.
•Voice quality has been improved comparing with VMIB/VMIB2/AAIB.
•Enhanced features are implemented
(Message forwarding and message rewinding while listening message)
•Add-on boards:
-. VMIBE : VCEUE, FMEU2
-.Item
AAIBEChannel
: VCEUE.System Greeting User Greeting Maximum Capacity
Basic : 4 ch Basic : 300 min
VMIBE 30 min 24 ch, 3boards / System
Option : 4 ch Option : 300 min
Basic : 4 ch
AAIBE 10 min 3 min 20 sec 8 ch, 1board / System
Option : 4 ch

Switching Functions
Switch Function Remark
SW1 SRAM back-up when power interruption or failure Should be ON
SW3 JTAG reset enable for DSP Don’t care. Development purpose
SW4 VMIBE reset button Development purpose

LED Indications
Status
No Description Remark
ON OFF
LED1 The status of channel 1 In use Idle
LED2 The status of channel 2 In use Idle
LED3 The status of channel 3 In use Idle
LED4 The status of channel 4 In use Idle
LED5 The status of channel 5 In use Idle
LED6 The status of channel 6 In use Idle
LED7 The status of channel 7 In use Idle
LED8 The status of channel 8 In use Idle
LED9 The status of CPU running In use Idle Only VMIBE

10/16
2. New Board Description
VCEUE/FMEU2

Description
•VCEUE: Provides additional 4 VMIBE channels.
•FMEU2: Provides additional 5 hours recording time of VMIB2 and VMIBE.
•The voice recording capacity of VMIBE and AAIBE
1. VMIBE
5 hours (System greeting : 30 minutes, User greeting : 4 hours and 30 minutes)
2. VMIBE with FMEU2
10 hours (System greeting : 30 minutes, User greeting : 9 hours and 30 minutes)
3. AAIBE
13 minutes (System greeting : 10 minutes, User greeting : 3 minutes)

Compatibility of VMIB/VMIB2/VMIBE with optional boards


/ AAIBE

VCEU FMEU FMEU2 VCEUE

VMIB OK OK NG NG

VMIB2 OK NG OK NG

VMIBE NG NG OK OK

11/16
2. New Board Description
MPBE/PMUE

Description
•The 32MB SDRAM is used for software downloading and additional features.
•Before installing the MPBE, you must install the PMUE.
•The MPBE must be used for expanding from LDK-300 system(300 ports) to LDK-300
Expansion system(600 ports) and installed on the MPB slot of the 1st KSU.
•To operate LDK-300 Expansion system, connect the CN 1 of MPBE to the CN1 of LMUE
with Link cable attaching ferrite core.
•MPBE doesn’t have one external page port and one external MOH port comparing with MPB
•The LMUE has one external page port and one external MOH port.

•Add-on Boards: PMUE, MODU

Description
•The PMUE has a program for system control, administration, and call processing.
•The PMUE is mounted on the MPBE.
•The PMUE has 8M bytes of four 70ns 16Mbit flash ROMs which is available of software
downloading by BDM(Board Debug Module) tool, ISDN line or LAN port.

12/16
2. New Board Description
MPBE/PMUE
Various switches and connector Functions
Switch/Connector Functions Remark
SW1 System Reset button
SW2 Memory backup switch Database back-up
CN1 Connection between Master system and Expansion system For expansion
CN2 and CN3 MODU connection
CN4 and CN5 RS-232C Serial Interface System Access
CN6 BDM connection For Debug Mode
CN7 Card Edge connection
CN8 JTAG port for CPLD For Programming
CN9 and CN10 PMUE connection

Function of SW3
Switch Function OFF ON
1 Administration Programming Access Disable Enable
2 CTS (Clear to Send) of RS-232C Enable Disable
3 Command/Event Trace (The purpose of testing software) Enable Disable
4 Not used - -
5 SMDI (Simplified Message Desk Control –Voice Mail ) SMDI ON SMDI OFF
6 Not used - -
7 Power up status trace of board Enable Disable
8 Database default on power up Disable Enable

LED Indications
LED No Status
LED1 ON - PLL circuit activation by external synchronous clock of ISDN board
(Red) OFF - PLL circuit activation by internal clock
LED2 Not used
LED3 Timer, Flashing every 100msec
LED4 Dial Processing, Flashing every 100msec
LED5 SLT Ring Processing, Flashing every 200msec
LED6 LCD active updating, Flashing every 300msec
LED7 Call Event Processing
LED8 RS-232C Tasking
LED9 Interrupt Processing
LED10 Collision detection for Ethernet port
LED11 Data transmission for Ethernet port
LED12 Data reception for Ethernet port
LED13 Data link for Ethernet port

13/16
2. New Board Description
LMUE

Description
•The LMUE is used to connect master system to expansion system for IP LDK-300E
•The LMUE has one external page port and one external MOH port.
•The LMUE is installed on the MPB slot of the 4th KSU.
•To operate LDK-300 Expansion system, connect the CN 1 of MPBE
to CN 1 of LMUE by Link Cable having ferrite core.

Switches and connectors Function


Switch /
Function Remark
Connector
Connection between Master system and
CN1 For expansion
Expansion system
PJ1(RED)
External paging and MOH connection
PJ2(BLUE)

14/16
2. New Board Description
LMUE

15/16
2. New Board Description
PSU-D

Description
•LDK-300 PSU-D is installed on the left first and second slot of the mother board.
•Two PSU-D can be inserted
•In case two PSU-D are inserted, the power is provided by the method of load sharing.
•If one is failed, another one supplies the power with the system.

PSU-D Specification
Item Specification
DC Voltage Input -48(-42 ~ -60) Volt DC
DC Power 320 W
DC Input Fuse 12.5 amp @ 48 Volt DC
DC Output Voltage +5, -5, +30 Volt DC

Power Supply Capacity


PSU +5V -5V +30V Battery Back Up Remark
PSU 10A 1.5A 8.4A 1A / 27.3V 350W
PSU3 5A 1A 7A 0.5A / 27.3V 250W
PSU-D 10A 1.5A 7.5A - 320W

16/16
Thank you