Академический Документы
Профессиональный Документы
Культура Документы
Optimisation
Agenda
Basics
Handover
Intra-frequency Handover
Inter-RAT Handover
OSS Tools
GPEH
WNCS
Counters/stats
Handover
Ec/Io
Assume 39dBm tx power
Assume 43dBm tx power
excl. Pilot power (33dBm)
Cell A
Cell B
120dB pathloss
100dB pathloss
dBm 33 39 42 mW =10^(dBm/10)
pathloss 100 100 120
x -67 -61 -78 -100 SUM (mW) RSSI (dBm)
1.99526E-
10^(x/10) 07 7.94328E-07 1.58489E-08 1E-10 8.10277E-07 -60.9137
Ec/Io -6.086336008
Discuss
RSSI, Io, No
RSCP, Ec
Cell self interference, other cells
Cell breathing
Umbrella cells
Tall sites
SHO
Soft Handover
Softer Handover
Maximal combining
Power control
Handover
Intra-frequency
Inter-frequency
Inter-system (Inter-RAT)
Intra-frequency Handover
Reporting event 1A: A Primary CPICH enters the reporting
range
Reporting event 1B: A primary CPICH leaves the reporting range
Reporting event 1C: A non-active primary CPICH becomes
better than an active primary CPICH
Reporting event 1D: Change of best cell
Reporting event 1E: A Primary CPICH becomes better than an absolute
threshold
Reporting event 1F: A Primary CPICH becomes worse than an absolute
threshold
Reporting event 1J: A Non-active E-DCH but active DCH Primary CPICH
becomes better than an active E-DCH Primary CPICH (FDD only)
More info: 3GPP TS 25.331
SHO Message flow
UE UTRAN
Measurement Report
Measurement Control
Event 1a
Measurement
Quantity
Measurement Report
CPICH2
TimeToTrigger1a
Event 1b
Measurement
Quantity
ReportingRange1b + Hysteresis1b / 2
CPICH1 (AS)
CPICH2 (AS)
Measurement Report
TimeToTrigger1b
Event 1c
Measurement
Quantity
CPICH1 (AS)
CPICH3 (MN)
Measurement Report
TimeToTrigger1c
Event 1d (Hs Cell Change)
Measurement
Quantity
CPICH2 (AS)
Measurement Report
TimeToTrigger1d
Notes
In previous slides, individual cell offsets and hysteresis 1a
and 1b are assumed to be zero for simplicity and easier
illustration
eventResults
EventResults : intraFreqEventResults
intraFreqEventResults
eventID : e1a
cellMeasurementEventResults
CellMeasurementEventResults : fdd
fdd :
[0 ] :
primaryScramblingCode : 95
Measurement Control
intraFreqMeasQuantity
filterCoefficient = fc2
modeSpecificInfo
fdd
intraFreqMeasQuantity_FDD = cpich_Ec_N0
reportCriteria
intraFreqReportingCriteria
eventCriteriaList[0]
event_
e1a
triggeringCondition = detectedSetAndMonitoredSetCells
reportingRange = 6
w=0
reportDeactivationThreshold = t2
reportingAmount = ra_Infinity
reportingInterval = ri1
hysteresis = 0
timeToTrigger = tt320
reportingCellStatus
allActivePlusMonitoredAndOrDetectedSet = viactCellsPlus3
Measurement Control
eventCriteriaList[1]
event_
e1b
triggeringCondition = activeSetCellsOnly
reportingRange = 10
w=0
hysteresis = 0
timeToTrigger = ttt640
reportingCellStatus
withinActiveSet = e3
Measurement Control
eventCriteriaList[2]
event_
e1c
replacementActivationThreshold = t3
reportingAmount = ra_Infinity
reportingInterval = ri1
hysteresis = 2
timeToTrigger = tt320
reportingCellStatus
allActivePlusMonitoredAndOrDetectedSet = viactCellsPlus3
Measurement Control
eventCriteriaList[3]
event_
e1d = NULL
hysteresis = 15
timeToTrigger = ttt2560
reportingCellStatus
allActivePlusMonitoredAndOrDetectedSet = viactCellsPlus1
Ericsson Parameters
releaseConnOffset (120)
maxActiveSet (3)
hysteresis1a, hysteresis1b (0)
hysteresis1c (4), hysteresis1d (15)
measQuantity1 (CPICH_EC_NO)
reportingInterval1a (3(1)), reportingInterval1c (3(1))
reportingRange1a (6), reportingRange1b (10)
timeToTrigger1a (320), timeToTrigger1b (640),
timeToTrigger1c (320), timeToTrigger1d (2560)
hsHysteresis1d (10(1)), hsQualityEstimate
(CPCIH_RSCP), hsTimeToTrigger1d (640)
Corner Effect / Fast Changing RF
Environment
AS MN
AS MN
Individual Cell Offset
individualOffset (UtranCell)
individualOffset (Adjacency)
individualOffset (GSM Adjacency)
Measurement Control
newIntraFreqCellList[2]
intraFreqCellID = 2
cellInfo
cellIndividualOffset = 0
modeSpecificInfo
fdd
primaryCPICH_Info
primaryScramblingCode = 361
Inter-Frequency Neighbours
Active Set
Monitored Set
Detected Set
No one-way neighbours
Intra-frequency Neighbours
Composite Monitored Set
AS Cell A Cell B Cell C A
B
C
A1 B1 C1 A1
B1
A2 B2 C2 C1
A2
A3 B3 C3 B2
C2
C9
A31 B31 C31 A10
B10
Inter-RAT Handover
Compressed mode
Event triggered vs Periodic reporting
Events
Event 2a: Change of best frequency
Event 2b: The estimated quality of the currently used frequency is below a
certain threshold and the estimated quality of a non-used frequency is
above a certain threshold
Event 2c: The estimated quality of a non-used frequency is above a certain
threshold
Event 2d:The estimated quality of the currently used frequency is
below a certain threshold
Event 2e: The estimated quality of a non-used frequency is below a certain
threshold
Event 2 f:The estimated quality of the currently used frequency is
above a certain threshold
Event 2d, 2f (entering and exiting
compressed mode)
Measurement
Quantity
CPICH_BEST
Threshold 2f
Threshold 2d
TimeToTrigger2d TimeToTrigger2f
Measurement Control
freqQualityEstimateQuantity_FDD = cpich_Ec_N0
.......
reportCriteria
interFreqReportingCriteria
interFreqEventList[0]
event2d
usedFreqThreshold = -10
usedFreqW = 0
hysteresis = 0
timeToTrigger = tt320
interFreqEventList[1]
event2f
usedFreqThreshold = -8
usedFreqW = 0
hysteresis = 0
timeToTrigger = ttt1280
…….
periodicalOrEventTrigger = eventTrigger
Measurement Control
freqQualityEstimateQuantity_FDD = cpich_RSCP
……
reportCriteria
interFreqReportingCriteria
interFreqEventList[0]
event2d
usedFreqThreshold = -90
usedFreqW = 0
hysteresis = 0
timeToTrigger = tt320
interFreqEventList[1]
event2f
usedFreqThreshold = -87
usedFreqW = 0
hysteresis = 0
timeToTrigger = ttt1280
Event-triggered Reporting
Event 3a:The estimated quality of the currently
used UTRAN frequency is below a certain
threshold and the estimated quality of the other
system is above a certain threshold
Event 3b: The estimated quality of other system is below a
certain threshold
Event 3c: The estimated quality of other system is above a
certain threshold
Event 3d: Change of best cell in other system
Event 3a
Measurement GSM
Quantity
CPICH
Threshold 3a
GsmThresh 3a
Measurement Report
TimeToTrigger3a
Event 3a
Measurement Control
newInterRATCellList[2]
interRATCellID = 29
technologySpecificInfo
gsm
interRATCellIndividualOffset = 0
bsic
ncc = 0
bcc = 6
reportCriteria
interRATReportingCriteria
interRATEventList[0]
event3a
thresholdOwnSystem = -12
w=0
thresholdOtherSystem = -95
hysteresis = 0
timeToTrigger = ttt100
reportingCellStatus
UE Tx Power
Reporting event 6A: The UE Tx power becomes larger than an absolute threshold
Reporting event 6B:The UE Tx power becomes less than an absolute
threshold
Reporting event 6C: The UE Tx power reaches its minimum value
Reporting event 6D:The UE Tx power reaches its maximum value
Reporting event 6E: The UE RSSI reaches the UE's dynamic receiver range
Reporting event 6F (FDD): The UE Rx-Tx time difference for a RL included in the
active set becomes larger than an absolute threshold
Reporting event 6F (1.28 Mcps TDD): The time difference indicated by TADV
becomes larger than an absolute threshold
Reporting event 6G: The UE Rx-Tx time difference for a RL included in the active
set becomes less than an absolute threshold
Event 6d, 6b
Measurement
Quantity
Max UE Tx Power
Threshold 6b
TimeToTrigger6d
TimeToTrigger6b
Measurement Control
reportCriteria
ue_InternalReportingCriteria
ue_InternalEventParamList[0]
event6d = tt320
ue_InternalEventParamList[1]
event6b
timeToTrigger = ttt1280
transmittedPowerThreshold = 18
measurementReportingMode
measurementReportTransferMode =
acknowledgedModeRLC
periodicalOrEventTrigger = eventTrigger
Ericsson Inter-RAT Parameters
txPowerConnQualMonEnabled (UE Tx monitoring switch)
hysteresis2d , hysteresis2f (0)
serviceOffset2dEcno, serviceOffset2dRscp (0)
timeToTrigger2dEcno , timeToTrigger2dRscp, timeTrigg6d (320)
timeToTrigger2fEcno, timeToTrigger2fRscps, timeTrigg6b (1280)
usedFreqThresh2dEcno (-12)
usedFreqThresh2dRscp (-97)
ueTxPowerThresh6b (18)
usedFreqRelThresh2fEcno (1), usedFreqRelThresh2fRscp (3)
utranRelThreshRscp (5)
gsmThresh3a (-95)
Event 3a Threshold
Ec/No Triggered:
usedFreqThresh2dEcno+ serviceOffset2dEcno+
utranRelThresh3aEcno
Rscp Triggered:
usedFreqThresh2dRscp+ serviceOffset2dRscp+
utranRelThresh3aRscp
UeTx triggered:
usedFreqThresh2dRscp+ serviceOffset2dRscp+
utranRelThresh3aRscp+ utranRelThreshRscp
Switches
FddGsmHoSupp true/false (enable or disable IRAT)
hoType (GSM_PREFFERED, IFHO_PREFERRED, NONE)
Cell versus RNC level parameters
Cell Level
usedFreqThresh2dEcno
usedFreqThresh2dRscp
Neighbour List IRAT
Max number of Neighbours 32
Limit the number of neighbours
Recommended < 15
Downlink CE utilisation:
pmSumDlCredits/pmSamplesDlCredits
Uplink CE utilisation:
pmSumUlCredits/pmSamplesUlCredits
Good Reading
ALEX
3GPP TS25.331 (www.3gpp.org)
Other 3GPP documents