Академический Документы
Профессиональный Документы
Культура Документы
by Daniel Brassel
(CTS - TPT)
Flow Control
Reliability
Build-ups
Vibrations
Erosion
Fan Selection
Kiln ID Fan
Raw Mill Fan energy
3
V p 10
N kW
V p 115 6000 10 3
N1 920 kW
1 0.75
V p 115 6000 10 3
N2 812 kW
2 0.85
Definitions:
Fan static pressure
Fan power
System resistance curve
n2
Volume Flow V2 V1
n1
2
n2
Static Pressure p St 2 p St 1
n1
3
n2
Power Requirement N2 N1
n1
p St 1 1 T2
p St 2 2 T1
T in degree Kelvin !
Outlet damper
Speed control
Fan changes
increase fan speed
increase wheel diameter
replace rotor
build-ups wear
vibrations
reliability
26 TPT/Bra - 30/07/2018 Main Fans
Example of build-ups
Burning Conditions
High Temperatures
Steam injection
Sand blasting
Dynamic balancing
30 TPT/Bra - 30/07/2018 Main Fans
Acoustic Cleaning Devices
acoustic horn
acoustic horn
compressed air
water
steam
compressed air
water
steam
Blade erosion
Direct protection
Increased thickness of wear parts
Direct hard surfacing
Glued-on ceramics
Deflector plates
36 TPT/Bra - 30/07/2018 Main Fans
Wear Protection by Particle Deflection
without with
Deflector
Continuous operation
vibrations
build-ups
wear
Fan efficiency
mechanical design
type of regulation
Equipment cost