Академический Документы
Профессиональный Документы
Культура Документы
Pressure meter
Borehole Instrumented
testing at 8 Foundation
investigation – pile load test at 4
locations – 32 recommendation
200 No’s locations
tests
Stage 1: Investigation Stage 2: Pile lengths Stage 3: Validation of Stage 4: Final say to go pile
completed optimization through in- design parameters & lengths at all support
Pile lengths arrived based situ testing to derive the construction methodology locations with geological
on lab, field SPT & shear parameters for pile foundation profile;
interpreted shear Final records for WMS, QA
parameters & QC during construction
of piles.
9/30/2018 1
Geotechnical - Soil profile/pile length
Start of project
Katni Murwara
End of project
Katni river
Junction
Overburden/Transported soil Residual soil followed by Overburden/Transported soil
followed by Residual soil –(A1) Limestone/Shale/Bauxite followed by Residual soil- (A3)
rock – (A2)
Stage 1 Investigation: Pile length for 1.2m diameter , 450MT based on Borehole investigation
9/30/2018 2
Geotechnical – PMT & Pile length Optimization
Why Pressure meter test (PMT)
From borehole investigation (SPT N), the shear strength (Cu) is varying along & across the project stretch. Hence
confirmation of this parameter is required through In-situ testing by conducting pressure meter test along the
project stretch at different depth within the expected pile length
PMT testing
9/30/2018 3
Geotechnical – Value Engineering
Quantity saving through value engineering
9/30/2018 4