Radwin winlink-1000
For E1 Link.
1. Indoor unit
IDU-E (Enterprise unit) or
IDU-C (Carrier class unit)
2. Outdoor unit.
3.Power Adaptor for IDU.
● LED Act (Red indication)-If RED LED glows, means PoE and ODU are communicating
and no problem in the connectivity between PoE and ODU.
Power LED
ODU LED
AIR IF LED
SERVICE LED
Ensure that IDU should be properly grounded to the nearby Earth. (refer page no 13).
Log in to the Winlink Manager and complete the Link installation Wizard.
If SERVICE LED glows RED but AIR IF glows Green, means RF Link is good but there is no
E1 Stream connected to the Trunk port.
• Ensure that E1 stream is connected to the correct trunk port of the IDU.
• Ensure that RJ 45 jack is correctly crimped and connected properly to the Trunk
port.
• Pin no 1 and 2 of the other end of the RJ 45 jack should be connected to the
Receiving port of the MUX.
• Pin no 4 and 5 of the RJ 45 jack should be connected to the transmitting port of the
MUX.
• NO indication in the SERVICE LED – Go to the Winlink 1000 configuration page
and enable Ethernet+E1 and apply the Same.
● If AIR IF glows red, means that internal connectivity are good but there is no
communication between Local Modem and Remote modem. Then follow the
below steps.
1.Ensure that Remote modem is in ON condition
2.Check the local modem configuration by logging in to winlink-1000 Manager.
3.Check the SSID, as both local and remote modem SSID should be the Same.
4.STP cable and shielded RJ45 jack should be used always for installation.Shieled RJ 45 jack must be
soldered well to the external shield of the cat 5e STP Cable.