Вы находитесь на странице: 1из 18

Part: TCD Code

Di1(Si210) Elevator / Trouble Shooting Ctrl No.: SI-TS-02-2


Page: 49/117
○ Operation CPU
TCD 84 R5SC Relay ON trouble Detection Application Si210
○ Speed CPU

[Meaning] R5SC ON condition lasts for over 540ms after R5SC OFF command signal. [Countermeasures]

1. Verify if the voltage of AB-01 is 48V .


2. Verify NORMAL/STOP in E&I panel is positioned
to NORMAL.
[Explanation]
3. Verify if R5SC relay is properly inserted.
4. The LED(red) of R5SC relay will light on while driving.
SWD_I[VI_R5SC] SWD_O[VO_R5SC] check_out
Verify if contacts are connected during LED lights on and
0x8001 0x8082
disconnected during LED lights off.
SWD_I[VI_R5SC] SWD_O[VO_R5SC] Coil[SV_INV_SW_FAIL] 0x923D 5. Check contacts when relay turns on.
6. Replace R5SC relay(contactor type).
0x8001 0x8082 0x9210 Coil[SW_SS_DSP_WD]

check_out
TMC_Start(R5SC_
ERROR_DETECT_T)

TMC_Check(R5SC_ERROR_
DETECT_T, FINISH_STATE) SWD_I[VI_R5SC]
TCD 84

0x8001
Part: TCD Code
Di1(Si210) Elevator / Trouble Shooting Ctrl No.: SI-TS-02-2
Page: 50/117
○ Operation CPU
TCD 85 R5SC Relay off trouble Detection Application Si210
○ Speed CPU

[Meaning] R5SC OFF condition lasts for over 540ms after R5SC ON command signal [Countermeasures]
1. Verify if the voltage of AB-01 is 48V .
2. Verify NORMAL/STOP in E&I panel is positioned
to NORMAL
[Explanation]
3. Verify if R5SC relay is properly inserted.
SWD_I[VI_R5SC] 4. The LED (red) of R5SC relay will light on while driving.
SWD_O[VO_R5SC] check_out
Verify if contacts are connected during LED lights on and
0x8001 0x8082
disconnected during LED lights off.
SWD_I[VI_R5SC] SWD_O[VO_R5SC] Coil[SV_INV_SW_FAIL] 0x923D 5. Replace R5SC relay (contactor type).

0x8001 0x8082 0x9210 Coil[SW_SS_DSP_WD]

check_out
TMC_Start(R5SC_
ERROR_DETECT_T)

TMC_Check(R5SC_ERROR_
DETECT_T, FINISH_STATE) SWD_I[VI_R5SC]
TCD 85

0x8001
Part: TCD Code
Di1(Si210) Elevator / Trouble Shooting Ctrl No.: SI-TS-02-2
Page: 51/117
○ Operation CPU
TCD 86 C1BR CTT. on trouble Detection Application Si210
○ Speed CPU

[Meaning] Even after 540ms away from C1BR off command, C1BR on is maintained. [Countermeasures]

P48

MC1ST-01 C1BR MC1BR-04 AA-08 AA-08


[Explanation]
13 14
SWD_I[VI_C1BR] SWD_O[VO_C1BR] check_out
3 4 DOC-131
0x8029 0x8080

SWD_I[VI_C1BR] SWD_O[VO_C1BR] Coil[SV_INV_SW_FAIL] 0x923D

0x8080 0x9210
1. Check voltage of AA-08 of DOC-131 from above circuit.
0x8029 Coil[SW_SS_DSP_WD]
• When C1BR driving section is ON : DC 48 V
check_out
• When C1BR driving section is OFF : 0 V
TMC_Start(R5SC_
ERROR_DETECT_T) 2. Check the state of input state indicating row(row 3)
TMC_Check(C1BR_ERROR_ column 10 on LCD of DOA-100.
DETECT_T, FINISH_STATE) SWD_I[VI_C1BR]
TCD 86
• When C1BR driving section is ON : 1
0x8029 • When C1BR driving section is OFF : 0
3. Check C1BR contact point of contactor.

• Even after 540ms away from OFF command of C1BR output, C1BR contact
does not turns OFF, and C1BR contact point input is ON is detected(driving
section ON failure).
• Even with C1BR contact off, C1BR contact point input on is detected, because
of contact point not being off(contact point melted and adhered).
Part: TCD Code
Di1(Si210) Elevator / Trouble Shooting Ctrl No.: SI-TS-02-2
Page: 52/117
○ Operation CPU
TCD 87 C1BR CTT. OFF trouble Detection Application Si210
○ Speed CPU

[Meaning] Even after 540ms away from C1BR on command, [Countermeasures]


C1BR off is maintained.
P48

MC1ST-01 C1BR MC1BR-04 AA-08 AA-08


[Explanation]
13 14
SWD_I[VI_C1BR] SWD_O[VO_C1BR] check_out 3 4 DOC-131
0x8029 0x8080

SWD_I[VI_C1BR] SWD_O[VO_C1BR] Coil[SV_INV_SW_FAIL] 0x923D

1. Check voltage of AA-08 of DOC-131 from above circuit.


0x8029 0x8080 0x9210 Coil[SW_SS_DSP_WD]
• When C1BR driving section is ON : DC 48 V
check_out • When C1BR driving section is OFF : 0 V
TMC_Start(C1BR_
ERROR_DETECT_T) 2. Check the state of input state indicating row(row 3)
TMC_Check(C1BR_ERROR_ column 10 on LCD of DOA-100.
DETECT_T, FINISH_STATE) SWD_I[VI_C1BR]
TCD 87
• When C1BR driving section is ON : 1
0x8029 • When C1BR driving section is OFF : 0
3. Check C1BR contact point of contactor.
4. Check BS1,BS2 switch
• Even after 540ms away from ON command of C1BR output, C1BR contact
does not become ON, and C1BR contact point input is OFF is detected(driving
section OFF failure).
• Even with C1BR contact on, C1BR contact point input off is detected, because
of contact point not being on(failure of contact point off).
Part: TCD Code
Di1(Si210) Elevator / Trouble Shooting Ctrl No.: SI-TS-02-2
Page: 53/117
○ Operation CPU
TCD 88 C1ST CTT. ON trouble Detection Application Si210
○ Speed CPU

[Meaning] [Countermeasures]
Even after 540ms away from C1ST off command, C1ST on is maintained.

P48

MC1ST-01 C1ST MC1ST-02 AA-07 AA-07


[Explanation]
21 22
Coil[SW_SS_48V_
SWD_I[VI_C1ST] SWD_O[VO_C1ST] DOWN_HOLD]
check_out 31 32 DOC-131
0x802A 0x8081 0x923C

SWD_I[VI_C1ST] SWD_O[VO_C1ST] Coil[SV_INV_SW_FAIL] 0x923D

1. Check voltage of AA-07 of DOC-131 from above circuit.


0x802A 0x8081 0x9210 Coil[SW_SS_DSP_WD]
• When C1ST driving section is ON : 0 V
check_out • When C1ST driving section is OFF : DC 48 V
TMC_Start(C1ST_
ERROR_DETECT_T) 2. Check the state of input state indicating row (row 3)
TMC_Check(C1ST_ERROR_ column 9 on LCD of DOA-100.
DETECT_T, FINISH_STATE) SWD_I[VI_C1ST]
TCD 88
• When C1ST driving section is ON : 1
0x802A • When C1ST driving section is OFF : 0
3. Check C1ST contact point of contactor.

• Even after 540ms away from OFF command of C1ST output, C1ST contact
does not become OFF, and C1ST contact point input is ON is detected.
• Even with C1ST contact off, C1ST contact point input on is detected, because
of contact point not being off.
Part: TCD Code
Di1(Si210) Elevator / Trouble Shooting Ctrl No.: SI-TS-02-2
Page: 54/117
○ Operation CPU
TCD 89 C1ST CTT. OFF trouble Detection Application Si210
○ Speed CPU

[Meaning] Even after 540ms away from C1ST on command, C1ST off is maintained. [Countermeasures]

P48

MC1ST-01 C1ST MC1ST-02 AA-07 AA-07


[Explanation]
21 22
Coil[SW_SS_48V_
SWD_I[VI_C1ST] SWD_O[VO_C1ST] DOWN_HOLD]
check_out 31 32 DOC-131

0x802A 0x8081 0x923C

SWD_I[VI_C1ST] SWD_O[VO_C1ST] Coil[SV_INV_SW_FAIL] 0x923D

1. Check voltage of AA-07 of DOC-131 from above circuit.


0x802A 0x8081 0x9210 Coil[SW_SS_DSP_WD]
• When C1ST driving section is ON : 0 V
check_out • When C1ST driving section is OFF : DC 48 V
TMC_Start(C1ST_
ERROR_DETECT_T) 2. Check the state of input state indicating row(row 3)
TMC_Check(C1ST_ERROR_ column 9 on LCD of DOA-100.
DETECT_T, FINISH_STATE) SWD_I[VI_C1ST]
TCD 89 • When C1ST driving section is ON : 1
0x802A • When C1ST driving section is OFF : 0
3. Check C1ST contact point of contactor.
4. Check if rope compensation function is applied.
• Even after 540ms away from ON command of C1ST output, C1ST contact - Data in address 0016 is ‘01’ or ‘FF’, even If the function is
does not become ON, and C1ST contact point input is OFF is detected. not applied. Change the data to ‘00’.
• Even with C1ST contact on, C1st contact point input off is detected, because of 5. If rope compensation function is applied, check R1ML Relay.
contact point not being on.
Part: TCD Code
Di1(Si210) Elevator / Trouble Shooting Ctrl No.: SI-TS-02-2
Page: 55/117
○ Operation CPU
TCD 90 SUPRESS ON trouble Detection Application Si210
○ Speed CPU

[Meaning] Even after 360ms away from driving OFF command from operation side [Countermeasures]
to speed side,ON feedback is maintained.
1. Check flickering condition of WDT LED(green) of DPC-122.
2. Check connection condition of communication cable(64P)
[Explanation] between operation and speed.
Coil[SV_INV_
Coil[RS_SUPPRESS_ON] RUN_STOP_FB] SWD_I[VI_C1ST] 3. Check flickering condition of SYS2 LED(green) of DOC-131.

0x91C3 0x9207
0x802A
Coil[SV_INV_
Coil[RS_SUPPRESS_ON] RUN_STOP_FB]

0x9207
0x91C3

SWD_O[VO_C1ST] SWD_I[VI_R5SC] Coil[SV_INV_SW_FAIL] check_out

0x8081 0x8001 0x9210

check_out
TMC_Start(SUPRS_
ON_OFF_DETECT_T)

TMC_Check(SUPRS_ON_OFF_
DETECT_T, FINISH_STATE) Coil[RS_SUPPRESS_ON]
TCD 90

0x91C3

Even suppress OFF command of operation control side is maintained for 360ms,
the suppress command which is a feedback from speed control side does not
become OFF, and maintain continuously ON.

[Symptom]

Sudden stop during running.


Part: TCD Code
Di1(Si210) Elevator / Trouble Shooting Ctrl No.: SI-TS-02-2
Page: 56/117
○ Operation CPU
TCD 91 SUPRESS OFF trouble Detection Application Si210
○ Speed CPU

[Meaning] Even after 360ms away from driving ON command from operation side [Countermeasures]
to speed side,OFF feedback is maintained.
•1. Check flickering condition of WDT LED(green) of DPC-122.
•2. Check connection condition of communication cable(64P)
[Explanation] between operation and speed.
Coil[SV_INV_ • Check flickering condition of SYS2 LED(green) of DOC-131.
Coil[RS_SUPPRESS_ON] RUN_STOP_FB] SWD_I[VI_C1ST]

0x91C3 0x9207
0x48082
Coil[SV_INV_
Coil[RS_SUPPRESS_ON] RUN_STOP_FB]

0x91C3 0x9207

SWD_O[VO_C1ST] SWD_I[VI_R5SC] Coil[SV_INV_SW_FAIL] check_out

0x8081 0x8001 0x9210

check_out
TMC_Start(SUPRS_
ON_OFF_DETECT_T)

TMC_Check(SUPRS_ON_OFF_
DETECT_T, FINISH_STATE) Coil[RS_SUPPRESS_ON]
TCD 91

0x91C3

Even suppress ON command of run control side is maintained for 300ms,


the suppress command which is a feedback from speed control side does
not become ON, and maintain continuously OFF.
[Symptom]

Sudden stop during running.


Part: TCD Code
Di1(Si210) Elevator / Trouble Shooting Ctrl No.: SI-TS-02-2
Page: 57/117
○ Operation CPU
TCD 92 R.E disconnected Detection Application Si210
○ Speed CPU

[Meaning] Disconnection of Rotary Encoder both phases (A, B) is detected [Symptom]

Sudden stop during running.

[Explanation] [Countermeasures]

ALM LED (Red color) on DOC-131 is turned on: Operation unable condition
1. Voltage check of AD connector in DOC-131 in stop.
With speed command is more than 1m/min and C1ST & C1BR is on PIN 1 : 15 V ± 5% (power supply of R/E)
1. In rope compensation operation, if the pulse of R/E doesn’t change for 4.86 seconds, PIN 2 : 0 V ± 0.5 V (GND)
the trouble occurs. PIN 3 : 0 V ± 0.5 V or 15 V ± 5%
2. In other operation (not rope compensation), if the pulse of R/E doesn’t change for PIN 4 : 0 V ± 0.5 V or 15 V ± 5%
1.62 seconds, the trouble occurs.
2. Check voltage of AD connector in DOC-140 during running.
Coil[RS_RUNNING] SWD_O[VO_C1BR] SWD_I[VI_C1BR] SWD_I[VI_C1ST]
PIN 1 : 15 V ± 5%
PIN 2 : 0 V ± 0.5 V
0x91C3 0x9207 0x9207 0x48082
PIN 3 : 7.5 V ± 5% (measuring DC by DMM)
PIN 4 : 7.5 V ± 5% (measuring DC by DMM)
SWD_O[VO_C1ST] Coil[IS_CMD_V_1]
check_out
0x91C3 0x91C3

check_out enco_diff == 0
TMC_Start(ENCODER_
DISCON_DETECT_T
TMC_Check(ENCODER_DISCON_ Coil[RS_ROPE_
DETECT_T,FINISH_STATE) COMPEN_REQUEST]
enco_input_er_cnt++
0x8081

enco_input_er_cnt > 2 TCD 92

TCD 92
Part: TCD Code
Di1(Si210) Elevator / Trouble Shooting Ctrl No.: SI-TS-02-2
Page: 58/117
○ Operation CPU
TCD 93 R.E pulse counter read trouble Detection Application Si210
○ Speed CPU

[Meaning] The difference is more than 1mm in reading the value of R.E twice. [Symptom]

Sudden stop during running.

[Explanation]

In case the difference that is more than 1mm in reading the value of R.E twice, occurs
more than 10 times, TCD is detected.
[Countermeasures]

See the countermeasures of TCD 92.


Part: TCD Code
Di1(Si210) Elevator / Trouble Shooting Ctrl No.: SI-TS-02-2
Page: 59/117
○ Operation CPU
TCD 94 R.E pulse counter trouble Detection Application Si210
○ Speed CPU

[Meaning] In case that the case of changed value between R.E counter value read [Countermeasures]
in current cycle and in the previous cycle exceeds 3 times, and
1. Check SPEC data from address 0100H ~ 0112H of control
this exceeded value is continued for 150ms, the trouble is detected.
SPEC.
2. Check if R.E is out of function. (Refer to TCD 92)
[Explanation]

• This can be generated when SPEC input is abnormal.


• This will be detected, if specs, such as T/M, gear, and speed does not match.
Part: TCD Code
Di1(Si210) Elevator / Trouble Shooting Ctrl No.: SI-TS-02-2
Page: 60/117
○ Operation CPU
TCD 95 R5SX OFF trouble (Safety line) Detection Application Si210
○ Speed CPU

[Meaning] [Countermeasures]
Off detected from hoist way and safety circuit.
1.Enter A21E in KEYPAD of DOA-100, to check address 8011
and verify the data if it is x01.
[Explanation] 2. Check voltage of each connector.

OFF detected when R5SX off is maintained more than 540msec. - CA-15 (DC 48V)
- GRS-01~02(GTC) , GRS-04~05(OS) , GRS-07,08(OBS)
- LSU-01~02(FLU) , LSD-01~02(FLD) ,Y1-02~Y1-01(SCS)
- Check voltage in sequence of Y1-02 ~ Y1-01 (SCS) AB-16,
to verify if voltage is DC 48V ± 5%, and if there are no
SWD_O[VO_
SWD_I[VI_V48] ROPE_GRIPPER] SWD_I[VI_R5SX]
check_out voltage detected, check the state of each switch.

TMC_Check(POWER_ 0x8094 0x8011 3. In step 2, if 48V is detected in AB-16, but the data of address
0x8010 Coil[SW_SS_48V_
READY_T, FINISH_STATE) DOWN_HOLD] 8011 is x00, input circuit is abnormal.
check_out r5sx_err_count > 3 4. Replace fuse resistor (R13) with spare.
TCD 95
5. Replace DOC-131 PCB

+1 r5sx_err_count Fuse resistor (R13)


Part: TCD Code
Di1(Si210) Elevator / Trouble Shooting Ctrl No.: SI-TS-02-2
Page: 61/117
○ Operation CPU
TCD 96 Operation mode input trouble Detection Application Si210
○ Speed CPU

[Meaning] [Countermeasures]
In case of ERO(E&I Panel) switch signal and ON_CAR TOCI switch
signal having input concurrent time, or no signal of operation being P48V DCL-243
inputted at the same time.
NORMAL CIN-02 RHIGH

[Explanation] $82AD

TMC_Check(POWER_ MAINT(INSPECTION) ONC-02 RONCAR


READY_T,FINISH_STATE) TCD 200 TCD 202 check_out
$82AF
CIN-03 RINCAR

check_out CND_F_Op[CN_HIGH] CND_F_Op[CN_IN_CAR] $82AE


input_err T.O.C.I BOX

0x82AE
0x82AD P48V [ In case of applying IN CAR Switch ] DCL-243
CND_F_Op[CN_ON_CAR]

0x82AF 2 1 OFF 2 3 NORMAL CIN-02 RHIGH


CND_F_Op[CN_IN_CAR] CND_F_Op[CN_ON_CAR] $82AD
3 1 MAINT CIN-03 RINCAR
0x82AE 0x82AF
$82AE
CND_F_Op[CN_HIGH] 0x82AE CND_F_Op[CN_ON_CAR] 5 6 ON 5 4 MAINT ONC-02 RONCAR
empty_err
$82AF
0x82AD 0x82AF
CND_F_Op[CN_IN_CAR] 4 6

input_err
990 msec ON CAR SW IN CAR
TMC_Start(OP_MODE_ MAINT SW
ERROR_DETECT_T)
1. Enter A21E in DOA-100 KEYPAD, and check data of
empty_err
3060 msec address 82AD,82AE and 82AF for each electric diagram.
TMC_Start(MODE_INPUT_
ERROR_DETECT_T)
2.Only one from above 3 input ports should be recognized as “H”.
TMC_Check(OP_MODE_ERROR_
TCD 96
3. 2. If there is no “H”, verify if ON CAR switch is positioned on
DETECT_T, FINISH_STATE)
ONCAR position and INCAR MAINT switch is not positioned on
MAINT.
TMC_Check(MODE_INPUT_ERROR_
DETECT_T, FINISH_STATE) 4. If there are two or more “H”, check the connection and voltage
of each phase.
Part: TCD Code
Di1(Si210) Elevator / Trouble Shooting Ctrl No.: SI-TS-02-2
Page: 62/117
○ Operation CPU
TCD 97 CDS trouble Detection Application Si210
○ Speed CPU

[Meaning] [Countermeasures]
When CDS is inputted after DOLS operation, the trouble is detected.
1. If 0V±0.5V is detected when measuring voltage of
Y2-03, CA-07 with DOLS, external condition is normal.
2. In case of 1, if LCD row 3 column 15 of DOA-100 is displayed
[Explanation] 1, input section of DOC-131 is normal.
3. After checking of 2, if LCD row 3 column 13 of DOA-100 is
Coil[SW_ Coil[SW_FS_ CND_F_Op[CN_ CND_F_Op[CN_ displayed 0, it is normal. If row 3 column 13 is 1, check
GS_IS_STOP] MAINT] IN_CAR] ON_CAR] SWD_I[VI_RDMC]
voltage of CA-08(CDS). After DOLS, CDS switch is opened, so
0x925D 0x929A 0x82AE 0x82AF 0x8060
0V must be displayed to be normal.
4. Check CDS switch of car if voltage of CA-08 level is 48V.
Coil[SW_SV_ Coil[SW_GS_ Coil[DC_
1ST_FIRE] DOOR_ZONE] CLOSE_CMD] TCD 188 TCD 171

0x9274 0x9250 0x908E

SWD_O
[VO_R2OP] SWD_I[VI_LDS]
check_out

0x8083 0x802C

SWD_I[VI_DOLS] SWD_I[VI_CDS]

0x802D
TMC_Check(R2CD_R2LD_ 0x802B
ERROR_DETECT_T,RUN_STATE)

check_out
990 msec TMC_Start(R2CD_R2LD_
ERROR_DETECT_T)
TMC_Check(R2CD_R2LD_
ERROR_DETECT_T,
FINISH_STATE) Coil[DC_DOLS] SWD_I[VI_CDS] TCD 97

0x90A6 0x802B
Part: TCD Code
Di1(Si210) Elevator / Trouble Shooting Ctrl No.: SI-TS-02-2
Page: 63/117
○ Operation CPU
TCD 98 LDS trouble Detection Application Si210
○ Speed CPU

[Meaning] When LDS is inputted after DOLS operation, the trouble is detected. [Countermeasures]

1.If 0V±0.5V is detected when measuring voltage of


Y2-03, CA-07 with DOLS, external condition is normal.
2.In case of 1, if LCD row 3 column 15 of DOA-100 is displayed
[Explanation] 1, input section of DOC-131 is normal.
3.After checking of 2, if LCD row 3 column 5 of DOA-100 is
Coil[SW_ Coil[SW_FS_ CND_F_Op[CN_ CND_F_Op[CN_ displayed into 0, it is normal. If row 3 column 5 is 1, check
GS_IS_STOP] MAINT] IN_CAR] ON_CAR] SWD_I[VI_RDMC] voltage of AB-15(LDS). After DOLS, LDS switch is
opened, so 0V must be displayed to be normal.
0x925D 0x929A 0x82AE 0x82AF 0x8060
4. Check LDS switch of hall if voltage of AB-15 level is 48V.
Coil[SW_SV_ Coil[SW_GS_ Coil[DC_
1ST_FIRE] DOOR_ZONE] CLOSE_CMD] TCD 188 TCD 171

0x9274 0x9250 0x908E

SWD_O
[VO_R2OP] SWD_I[VI_LDS]
check_out

0x8083 0x802C

SWD_I[VI_DOLS] SWD_I[VI_CDS]

0x802D
TMC_Check(R2CD_R2LD_ 0x802B
ERROR_DETECT_T,RUN_STATE)

check_out
990 msec TMC_Start(R2CD_R2LD_
ERROR_DETECT_T)
TMC_Check(R2CD_R2LD_
ERROR_DETECT_T,
FINISH_STATE) Coil[DC_DOLS] SWD_I[VI_LDS] TCD 98

0x90A6 0x802C
Part: TCD Code
Di1(Si210) Elevator / Trouble Shooting Ctrl No.: SI-TS-02-2
Page: 64/117
○ Operation CPU
TCD 99 Dual input signal trouble Detection Application Si210
○ Speed CPU

[Meaning] Different contact states of the same inputs between operation CPU and [Countermeasures]
speed CPU exceeds for 300ms. 1. Check trace data of TCD 99 by means of ‘A42E’ trace mode.
2. The meaning of each bit is as left table, in case that ‘1’ is set
at one of bit, meaning of the bit is the reason of trouble.
[Explanation]

Bit of operation CPU input main_in

Bit of speed CPU input inv_in

main_in inv_in ICD_Dual_Input_Error


0x8106

ICD_Dual_Input_Error err_count >= 7


TCD 99
0x8106

err_count ++

Trace Data Format


b15 b14 b13 b12 b11 b10 b9 b8
HIGH M/R
Maint

b7 b6 b5 b4 b3 b2 b1 b0

SD1D SD1U LDC DOLS R2LD C1BR C1ST R5SC


Part: TCD Code
Di1(Si210) Elevator / Trouble Shooting Ctrl No.: SI-TS-02-2
Page: 65/117
○ Operation CPU
TCD 100 SD1D ON trouble Detection Application Si210
○ Speed CPU

[Meaning] [Countermeasures]
SD1D does not operate from bottom floor.
1.Check the value of address 8023 from MEMORY READ
MODE, when car is not in bottom floor. If it is x00, it is normal.
If it is x01, check voltage of LSD-05, LSD-06 and HA-02. They
[Explanation] must have DC 48V.
DC48V is normal, if not, check wiring and connection.
It is detected when SD1D input does not enter when car is in bottom floor.
2. Check the value of address 8023 from MEMORY READ
TCD 77 TCD 78 TCD 114 ERD_Digi_Fl_Err MODE when car is in bottom floor. If it is x01, it is normal. If it
is x01, check voltage of LSD-06 and HA-02, and They must
have DC 0V.
Coil[SV_ Coil[SW_SS_48V_ Coil[AC_OP_ Coil[AC_OP_FHM_
FORCE_DECEL] DOWN_HOLD] FHM_MODE] START_MODE] 3. Check if SDS switches works normally.
0x921D 0x923C 0x9031 0x9032
4. Check assembly condition of SDS1D
Coil[SW_GS_
OPEN_ZONE] Coil[AC_OP_MAINT_MODE] SWD_I[VI_LDC]
check_out
0x9256 0x9030 0x8025

Coil[IS_ZERO_V]

0x91F2

FTD_Current_Fl ==
check_out SPD_Floor_Spec.Bottom SWD_I[VI_SD1D]
TCD 100

0x8023
Part: TCD Code
Di1(Si210) Elevator / Trouble Shooting Ctrl No.: SI-TS-02-2
Page: 66/117
○ Operation CPU
TCD 101 SD2D ON trouble Detection Application Si210
○ Speed CPU

[Meaning] [Countermeasures]
SD2D does not operate from bottom floor.
1.Check the value of address 8024 from MEMORY READ
MODE, when car is not in bottom floor. If it is x00, it is normal.
If it is x01, check voltage of LSD-07, LSD-08 and HA-03. They
[Explanation] must have DC 48V.
DC48V is abnormal, check wiring and connection.
Detected only when the rated speed is 90m/min or more.
Detected when SD2D input does not enter when car is on the bottom floor. 2. Check the value of address 8024 from MEMORY READ
MODE when car is in bottom floor. If it is x01, it is normal. If it
is x01, check voltage of LSD-08 and HA-03, and They must
TCD 77 ERD_Digi_Fl_Err
have DC 0V.
TCD 78 TCD 114

3. Check if SDS switches works normally.


Coil[SV_ Coil[SW_SS_48V_ Coil[AC_OP_ Coil[AC_OP_FHM_
FORCE_DECEL] DOWN_HOLD] FHM_MODE] START_MODE] 4. Check assembly condition of SDS2D

0x921D 0x923C 0x9031 0x9032

Coil[SW_GS_
OPEN_ZONE] Coil[AC_OP_MAINT_MODE] SWD_I[VI_LDC]
check_out
0x9256 0x9030 0x8025

Coil[IS_ZERO_V]

0x91F2

FTD_Current_Fl ==
check_out SPD_Floor_Spec.Bottom SWD_I[VI_SD2D] TCD 101

SPD_Control_Spec. 0x8024
Contract_Velocity >= 90

Вам также может понравиться