Вы находитесь на странице: 1из 24

Contents

M6000-3S Overview
M6000-3S Board Introduction
M6000-3S Power Heat Dissipation System
Internal use only▲

Overview
ZXR10 M6000-S is a carrier-class router. It is used for M6000-18S
MAN of operators, WLAN, IDC and backbone
convergence network of the Government & Enterprise
Network, providing 200G/400G solution scheme, and M6000-8S Plus
granted with 1T evolution capability so as to meet the
demand of service bearing and network evolution for
Government & Enterprise Network clients. M6000-8S

M6000-5S
M6000-3S

Height: 4U (DC)/ 5U (AC) Height: 7U (DC)/ 8U Height: 14U (DC) Height: 22U (DC/AC) Height: 41U (DC/AC)
Number of service slots: 3 (AC) Number of service Number of service Number of service
Switch system: Full mesh Number of service slots: 8 slots: 8 slots: 18
Power supply: AC/DC, 1+1 slots: 5 Switch system: 3+1 Switch system: 3+1 Switch system: 6+2
Switch system: 1+1 Power supply: DC, 2+2 Power supply: AC/DC, Power supply: AC/DC
Power supply: AC/DC, 4+4/5+1 8+8/11+1
1+1
Internal use only▲

Networking Location

Terminal/Access Layer Convergence Layer Backbone Network Service Layer

DHCP/ BSS/
NMS AAA
BRAS DNS OSS

OAM
HG SW/ONU OLT/Agg SW ISPA ISPB
SR/MSE
SW/OLT CR
VAS IP
FTTB/C Public Plane Internet
MGCF/IM-MGW
Traffic Analysis System
P IGW IMS
PE
VIP
IP RAN/Metro IPTV
PE
BS MPLS IDC
Telecom Plane
AG
PDSN/GGSN
Internal use only▲

ZXR10 M6000-3S
Power AC
DC
module HVDC
Single-
Port capacity 600Gbps
module
2650W 2675W
output
Slot throughout
power 200G
Power
capacity
redundan 1+1 1+1
cy
Service slot 3
Variable rate fan
Fan shelf x 3 175 ×442 ×738
2 dual-fans/module
Outline 4RU (DC shelf)
dimension
Service line card
mm H×W×D 219.4 ×442 ×738
PFU x 3
5RU (AC shelf)

Main control switch Non area-based


MFU x 2
power supply
power supply
Main control 1 + 1 mode
redundancy DC/AC/HV DC
Switch load sharing
Internal use only▲
Introduction to Cabinet

Parameters
Standard IEC60297-2
220mm*600mm*800mm(
Dimension height*width*depth)
Capacity 47U
Height 124kg
Capability 19-inch standard device

•Noise isolation
•Anti dust
•Anti mouse
Contents
M6000-3S Overview
M6000-3S Board Introduction
M6000-3S Power Heat Dissipation System
内部公开▲ Internal use only▲

M6KS-MPU-A Main Control Board

7
M6KS-MPU-A Main Control Board 内部公开▲ Internal use only▲

Panel Flag Interface Type Remarks

MGMT ETH RJ45 interface This interface is used to download version


and monitor network ports.
CONSOLE RJ45 interface It is used to connect background
management terminal. On the background
management terminal, you can use
associated tools such as hyper terminal to
operate and maintain ZXR10
M6000-S.
AUX RJ45 interface It is connected to Modem, being used for
remote management.
USB USB interface Slot interface of the USB storage device
GPS IN RJ45 interface It is used for external GPS clock input.
GPS OUT RJ45 interface It is used for external GPS clock output.
CLK1 SMB It is used for external 2.048 MHz or 2.048
Mbit/s clock input/output.
CLK2 SMB It is used for external 2.048 MHz or 2.048
Mbit/s clock input/output.

8
M6KS-MPU-A Main Control Board 内部公开▲ Internal use only▲

Module Indicator Indicator Remarks


color
System operation state RUN Green It is the system running indicator. It flashes when the system is running
properly.

ALM Red It is the system alarm indicator. When a fault occurs, it lights up. It dims
out when the system is in normal state.

ACT Green System active indicator. It is on when the board is active and off when
the board is standby.

OFL Red Indicates whether hot swapping is allowed.

Off: The board is operating properly and hot swapping is disallowed.

Constantly on: Hot swapping is allowed.


Gigabit electrical port ACT Yellow The ACT indicator for the first gigabit electrical interface. It flashes when
there are packets being sent and received.

LINK Green The link indicator for the first gigabit electrical interface. It is turned on
when the link is normal. .

9
内部公开▲ Internal use only▲

M6KS-MPU-A Main Control Board

Button Function Description

FUN Function button. It is used to collect the system operation state and configuration. Press this button for more than 6
seconds.
RST It is used to reset the whole board.

EXCH/OFL Active/standby changeover button. It is used to change over between the active board and the standby board
manually. When the board is a standby board, this button is a hot swapping button.

10
内部公开▲
Internal use only▲

Network Processing Board (M6KS-PFU-101-H2)

Indicator Indicator Remarks


color
RUN/ALM Green/red System operation state indicator/alarm indicator. When the system is
operating properly, it flashes in green. The cycle is 1 second. In other
situations, it is constantly on in red. .

11
内部公开▲
Internal use only▲

Line Interface Daughter Card (RPH-06XGE-SFP+-S )

Interface: RPH-06XGE-SFP+-S uses SFP+ optical modules


Button : RPH-06XGE-SFP+-S provides an OFL button.
The card is requested for hot-swapping when the button is pressed for a long time.
The button is used together with the OFL indicator.

12
内部公开▲
Internal use only▲

Line Interface Daughter Card (RPH-06XGE-SFP+-S )

There are 6 SFP+ interfaces on the RPH-06XGE-SFP+-S panel. One ACT


indicator and one LNK indicator are provided for each interface

Indicator Indicator Remarks


color
ACT Green Data receiving and sending indicator. When data is being sent or received,
it flashes at a fixed frequency.
LNK Green Physical connection indicator. After the system is started properly, if there
is a physical connection, it is on. If there is no physical connection, it is off.

13
内部公开▲
Internal use only▲

Line Interface Daughter Card (RPH-06XGE-SFP+-S )

STATUS indicator

State Green Red Description

Power-on initialization On for 0.5 s On for 0.5 s The indicator can be used normally.
It is lit green at first and then turns to red

Off Off Power-on failed

Device initialization Flashing at 1 Hz Off The device is being initialized.

Off Flashing at 1 Device initialization failed.


Hz
The card starts normally On Off The card is operating properly.

Off Flashing at 1 There is an exception on this card.


Hz
Off On This card can be removed.

14
内部公开▲
Internal use only▲

Line Interface Daughter Card (RPH-06XGE-SFP+-S )

OFL indicator

State Description

Solid on The daughter card is hot-swappable.

Off The daughter card receives no hot-swapping instruction or it is not hot-


swappable.

Flashing at 2 Hz The daughter card is receiving a hot-swapping instruction.

15
内部公开▲
Internal use only▲

Line Interface Daughter Card (RPH-12GE-SFP-S )

Interface: RPH-12GE-SFP-S uses SFP optical modules


Button : RPH-12GE-SFP-S provides an OFL button.
The card is requested for hot-swapping when the button is pressed for a long time.
The button is used together with the OFL indicator.

16
内部公开▲
Internal use only▲

Line Interface Daughter Card (RPH-12GE-SFP-S )

There are 12 SFP interfaces on the RPH-12GE-SFP-S panel. One ACT


indicator and one LNK indicator are provided for each interface

Indicator Indicator Remarks


color
ACT Green Indicates the status of data flow on the port:
Off: No data is received or sent through the port.
Flashing: Data is being received or sent through the port.
LNK Green Indicates the link status on the port:
Off: The link on the port is not connected.
Solid on: The link on the port is connected..
17
内部公开▲
Internal use only▲

Line Interface Daughter Card (RPH-12GE-SFP-S )

STATUS indicator

State Green Red Description

Power-on initialization On for 0.5 s On for 0.5 s The indicator can be used normally.
It is lit green at first and then turns to red

Off Off Power-on failed

Device initialization Flashing at 1 Hz Off The device is being initialized.

Off Flashing at 1 Device initialization failed.


Hz
The card starts normally On Off The card is operating properly.

Off Flashing at 1 There is an exception on this card.


Hz
Off On This card can be removed.

18
内部公开▲
Internal use only▲

Line Interface Daughter Card (RPH-12GE-SFP-S )

OFL indicator

State Description

Solid on The daughter card is hot-swappable.

Off The daughter card receives no hot-swapping instruction or it is not hot-


swappable.

Flashing at 2 Hz The daughter card is receiving a hot-swapping instruction.

19
Contents
M6000-3S Overview
M6000-3S Board Introduction
M6000-3S Power Heat Dissipation System
Internal use only▲

M6000-3S AC Power

1 Switch

2 Handle

3 Power supply input connector

4 Setscrew

Indicator Indicator color Remarks

RUN GREEN working normal

ALM RED when a fault occurs, it


lights up
Internal use only▲

Heat Dissipation System

The heat dissipation system of M6000-2S consists of the following components.


※two fan modules
※temperature sensor
※system ducts
※air filter
The fans used in this system are dual-reverse fans. There are two rotors in each
fan. The fan modules can automatically adjust their rotation speeds in
accordance with the real-time temperature. When a rotor fails, the other rotor
and other fans will operate. When a single fan fails, the heat dissipation system
can ensure the device to operate below the temperature of 40°C for a short
term
Internal use only▲

Heat Dissipation System

In a DC power supply module,


the air enters the module from
the right side and leaves the
module from the rear side. The
air inlets are on the right rear
side. The air outlets are the
same as those of the system
air duct. The two air ducts use
the same group of fans.
Thank you!

Вам также может понравиться