31 2006 Internal
Data Configuration
Note: The only difference between the two configuration modes is the
process that the configuration data takes effect
Level Authority
Guests Guests can only view the data.
Users In addition to the authority of guests, users can also perform
system maintenance, such as equipment maintenance, alarm
management, and performance management.
One GDPUC board can handle 968 voice channel, GDPUC board take N+1
configuration mode, all TC resource is shared in resource pool mode
In fact, all the boards can be configured in all slots except GTNU and
GSCU, but considering engineering, LMT give us a standardization
configuration:
GSCU fixed to occupy slot 6 and 7 in GMPS/GEPS/GTCS frame
Choose Start > Programs > HUAWEI Local Maintenance Terminal >
BSC6000V900R001Cxx > BSC6000 Local Maintenance Terminal to
start the BSC6000 Local Maintenance Terminal :
After the BSC properties are configured, they take effect in the entire
BSC. Do not modify these properties unless necessary.
After the BSC properties are configured, they take effect in the entire
BSC. Do not modify these properties unless necessary.
Line clock
For a remote subrack, the line clock extracted form the A interface
serves as the reference clock.
For a local subrack, the line clock extracted form the A interface serves
as the reference clock or system clock
Add a cabinet
The BSC device configuration refers to
the addition, deletion, property Add a subrack
Add a board
The cabinet where the power distribution box is located has at least one
subrack configured
The subrack that controls the power distribution box is already configured
The GGCU, GTNU, and GSCU can be deleted only when their
subracks are deleted
Each GXPUM and GXPUC has four CPUs, ranging from 0 to 3. Each
of the other boards has only one CPU
The entire BSC requires an active and a standby Ater OMLs. These
two Ater OMLs are configured in the GMPS
Adding a BTS
Moving a BTS
The number of cells under a BTS cannot exceed 12. A cell supports a
maximum of 24 TRXs
The maximum number of TRXs that a BTS supports varies with the BTS
type
The active TMU boards and the TRX boards cannot be added in this
operation
You cannot delete active TMU boards or TRX boards in this operation
Add a cell
To add a cell
If the added cell has adjacent cells, modify the cell handover
parameters to configure the cell adjacent relationship after adding
the cell
Adding TRXs may cause the lack of timeslots and the need of adding
subracks and boards
You must type a file name during the backup of GBAM data
In the Back up data of GBAM dialog box, select a file, and then select
Obtain file from GBAM
To check whether the data of a board in the LMT and that in the
GBAM is consistent
Ensure that the extensions of the result files are .xml
LMT GBAM
Loading