Вы находитесь на странице: 1из 22

TRAYS

Column Internals

• Column internals are


installed in distillation • They promote an intimate
columns to provide better contact between both
mass and heat transfers phases.
between the liquid and • The type of internals
vapour phases in the selected would determine
column. the height and diameter
• These include trays, of a column for a
packings, distributors and specified duty because
redistributors, baffles and different designs have
etc. various capacities and
efficiencies
Tray Column

• Tray Columns utilize a • The vapour must overcome


pressure and this liquid head to move up
the column.
temperature differential
• On the tray the vapour and
to separate the products.
liquid are contacted
• For most tray columns, becomes bubble or froth
the weir holds a liquid where the mass transfer
level of each tray takes place and then above
the tray they are separated
• Liquid enters from the where froth flows over the
down-comer of the tray outlet weir and vapour with
above. the light volatile compound
is disengaged
• The trays are used to bring the rising vapour
and falling liquid into intimate contact.
• Tray towers do the same job as packed towers
but they are very much more efficient in the
separation process than packed towers and,
they are also more costly
Types of Tray

• Each tray should be designed so as to give as efficient a


contact between the vapour and liquid as possible,
within reasonable economic limits
• There are various types of tray in use and the type
selected depends upon the degree of product purity
required, the type of fluids, fluid velocity and other
process parameters of the system
 Valve tray
 Sieve tray
 Bubble cap tray
Valve tray

• In valve trays, perforations are covered by liftable


caps.
• Vapour flows lifts the caps, thus self creating a
flow area for the passage of vapour.
• The lifting cap directs the vapour to flow
horizontally into the liquid, thus providing better
mixing
Advantages
• Excellent liquid/ vapour
contacting.
• Higher capacity.
• Can handle higher
loadings.
• Low-pressure drop than
bubble cap
Sieve tray

Is simply a metal plate • Advantages:


containing drilled holes • Simple construction Low
through which the rising entrainment,
vapour can pass into the
liquid flowing across the tray • Low maintenance cost
• Low fouling tendency

o They have comparable


capacity as valve trays Disadvantage
Less-flexible to varying loads than
other two types
Because of their efficiency, wide operating range, ease of
maintenance and cost factors, sieve and valve trays have
replaced the once highly thought of bubble cap trays in
many applications
Bubble cap tray
• A bubble cap tray has riser or chimney fitted
over each hole, and a cap that covers the riser.
• The cap is mounted so that there is a space
between riser and cap to allow the passage of
vapour.
• Vapour rises through the chimney and is
directed downward by the cap, finally
discharging through slots in the cap, and
finally bubbling through the liquid on the tray.
Advantages Disadvantages
• Moderate capacity • High entrainment
• Can provide • High fouling
excellent turndown tendency
• High cost
• High pressure drop
Comparison between Common Conventional Trays

S.No Factors Sieve Tray Valve Tray Bubble-Cap Tray

1
Capacity High High Moderately High
2
Efficiency High High Moderately High
3
Entrainment Moderate Moderate High
4
Pressure Drop Moderate Moderate High
5 20-50% more than
Cost Low sieve tray High
6 Low Low to moderate High: Tends to
Fouling tendency collect solids
• Each tray has 2 conduits, one on each side, called
‘downcomers’.
• Liquid falls through the downcomers by gravity from
one tray to the one below it.
• A weir on the tray ensures that there is always some
liquid (holdup) on the tray and is designed such that
the holdup is at a suitable height
• Being lighter, vapour flows up the column
and is forced to pass through the liquid, via
the openings on each tray.
• The area allowed for the passage of vapour
on each tray is called the active tray area
• As the hotter vapour passes through the
liquid on the tray above, it transfers heat to
the liquid. In doing so, some of the vapour
condenses adding to the liquid on the tray
Packings versus Trays

A tray column that is facing throughput problems may


be de-bottlenecked by replacing a section of trays with
packings. This is because
Packings provide extra inter-
facial area for liquid-vapuor Packed columns are called
contact continuous-contact columns
efficiency of separation is while trayed columns are called
increased for the same column staged-contact columns because
height of the manner in which vapour
packed columns are shorter than and liquid are contacted
trayed columns
Pressure drop

• Capacity of tray depend on • There are two main


pressure gradient through components to the pressure
the column, otherwise the drop:
vapour would not flow. 1. The "dry tray" drop caused
• This gradient is normally by restrictions to vapour
expressed in terms of flow imposed by the holes
pressure drop. and slots in the trays and
• Pressure drop controlled 2. The head of the liquid that
the path of vapor through the vapour must flow
the tray above and liquid through
flow
Height of weir

• The height of weir is • The weir height is


responsible for the determined by the
pressure drop and the requirement of the liquid
separation efficiency of depth on the tray which
a tray. is controlled by the depth
• The height of weir of seal over the vapor
depends on kind of tray. passage.
Downcomer

• The downcomer is a • If the downcomer can


vertical channel that not handle the liquid
connects a tray with the loading, downcomer
next tray below which flooding can be
carries froth and creates achieved that can reduce
residence time which efficiency.
helps the vapour • There are several type
disengage from the froth of down comer
• Downcomer assist the
froth generation
improve efficiency

Вам также может понравиться