Академический Документы
Профессиональный Документы
Культура Документы
HUAWEI BTS3900A
Hardware Structure
ISSUE4.1
www.huawei.com
HUAWEI Confidential
The BTS3900A developed by Huawei is an outdoor macro
BTS that performs the same tasks as the BTS3900. The
BTS3900A mainly consists of the BBU and DRFUs. Compared
with traditional BTSs, the BTS3900A features simpler structure
and higher integration.
PSTN
MS TUP,ISUP ISDN
BTS3900A PSPDN
BSC
A Interface
MS MSC/VLR
MAP
BTS3900A
BTS HLR/AUC/EIR
SMC/VM
MS
BTS3900A OMC
MS: Mobile Station BTS: Base Transceiver Station BSC: Base Station Controller
HLR: Home Location Register AUC: Authentication Center EIR: Equipment Identity Register
MSC: Mobile Switching Center VLR: Visitor Location Register SMC: Short Message Center
VM: Voice Mailbox OMC: Operation and Maintenance Center DBS:Distributed Base Station
(1) RF cabinet (2) Double radio filter unit (3) Fan module
1 2
SW1 ON ON The E1 impedance is set to 75 Ω.
ON OFF ON OFF The E1 link of the Level 2 cascaded BTS can be bypassed.
OFF OFF ON OFF The E1 link of the Level 3 cascaded BTS can be bypassed.
ON ON OFF OFF The E1 link of the Level 4 cascaded BTS can be bypassed.
OFF ON OFF OFF The E1 link of the Level 5 cascaded BTS can be bypassed.
EXT-ALM0 RJ45
MON0 RJ45
EXT-ALM0 RJ45
MON0 RJ45
INSIDE DB25 male E1 transfer cable Transfers the four E1/T1 signals between the UELP
connector of the BBU and the GTMU
OUTSIDE DB26 male E1/T1 cables of Provides the input and output of the four E1/T1
connector the BBU signals between the BBU and the BSC
The UELP has one DIP switch, which is used to set the impedance on the
E1/T1 port. There are four DIP bits on the DIP switch.
DIP Switch DIP Status Description
1 2 3 4
S1 ON ON ON ON The E1 impedance is set to 75 ohms. The E1
is grounded (unbalanced mode).
OFF OFF OFF OFF Other modes
PMU (Power and Environment Monitoring Unit) module manages the power
supply and batteries. The DPMU is the core of the power monitoring system.
PSU (Power Supply Unit) module Converts the 220 V AC power into the -48 V
DC power.
Wiring unit is used to connect with 220VAC power input cable and connects the
cable from DCDU module.
Ports Function
RS232/RS422 Used in communication with the central processing unit.
port
Battery switch The battery switch has two control ports ON and OFF, which are used for
switching on and switching off the battery.
Press and hold the port ON for 5-10 seconds to switch on the battery.
Press and hold the port OFF for 5-10 seconds to switch off the battery.
Power supply Two power supply test holes -48V and 0V are available for measurement
test port through an ordinary multi-meter.
COM port Used in connection to the external signal transfer board.
(1) PMU Module (2) PSU Module (AC/DC) (3) Wiring Unit
SN Port Function
1 ALM Connecting the monitoring signal
cable between the AFMU and the
APMI
2 DC Connecting the DC power cable
INPUT of the AFMU
COM2 RJ45 connector Providing the extended RS485 port to be cascaded with other devices
Power RFU0-RFU5, RFU0-RFU2 control the DC outputs to three DRFUs on the left of
switch FMUA, and the cabinet. RFU3-RFU5 control the DC outputs to three DRFUs
Spare on the right of the cabinet. FMUA controls the DC output to the
FMUA. Spare controls the DC output of the Spare.
Power RFU0-RFU5, RFU0-RFU2 supply power to three DRFUs on the left of the
output port FMUA, and cabinet. RFU3-RFU5 supply power to three 3 DRFUs on the right
Spare of the cabinet. FMUA supplies power to the FMUA. Spare is
reserved.
Boolean The first group Dry contact connectors Extended Boolean ports
port (from left to right)
The second group Dry contact connectors
The third group Dry contact connectors Smoke sensor port, door status sensor port
The fourth group Dry contact connectors Water sensor ports
Processing Unit
Interface
ANT1
DUP
CPRI0
ANT2
CPRI1
DUP
Transmit Combining
Processing Unit
Interface
ANT1
DUP
CPRI0
ANT2
CPRI1
DUP
ANT1
DUP
CPRI0
ANT2
CPRI1
DUP
ANT1
DUP
CPRI0
ANT2
CPRI1
DUP
ANT1
DUP From RX-in, TRX
can also use the
channel A of the
other DRFU, so
CPRI0 channel B of the
DUP
ANT2 two DRFUs are
canceled
CPRI1
RX-IN
RX_OUT
2 channels
from the other
Processing
Interface
ANT1
DRFU
CPRI0
CPRI1
ANT2
DUP
RX-IN
RX_OUT
Processing
Interface
ANT1
CPRI0
ANT2
CPRI1
DUP
RX-IN
RX_OUT
DRFU Topology
The BBU and DRFUs support multiple network topologies such as star, chain, and
ring topologies.
Only optical fiber can be used between DRFU and BBU.