Clinical Diagnosis
Total Solutions for Clinical Diagnosis 1
HbA1c Clinical Significance, Disease Diagnosis and Principle
Features Benefits
Greater Sensitivity of 3.3% with advanced • Its Liquid stable, ready to
Immuno Turbidimetric Method. use and supplied along with
4X Longer Shelf Life ( 24 months @ 2-8Deg.C & 1 calibrators .
Month on Board) • The Kit is equivalent to
5X Longer Calibration Stability ( 30 days) Gold Standard HPLC
99 % Correlation with HPLC method.
Linearity of 15.7 % as per Industry Standards. • It is adaptable to all open
Standardised to IFCC reference Fully auto Analyzers and
method.Convenient Pack Size Semiauto Analyzers.
The normal range for Non Diabetics : 4-6%; Target of Therapy < 7 %; Change of
Therapy - > 8%
3
Disease Diagnosis :It is used to screen for early renal disease in diabetic patients.
Principle :The principle of this test is a based upon Immuno Turbidimetric method.
Features Benefits
• Quantitative estimation of Microalbumin
• Calibrator included
• Small and Big pack size • Ready to use R1 and R2
• Wide measuring range of 0- 400 mg/L Reagents,hence there is no
• No Hook effect up to 6000 mg/L need of reagent
• Additional Quality Controls available preparation
• No interference from Triglycerides up to 2500 • The Kit is Adaptable to Fully
mg/dl, Bilirubin up to 15 mg/dl and Semi Auto Analyzers.
• Longer shelf life of 24 months
Normal range of Micro Albumin is from 0–25 mg/l (IFCC)
Disease Diagnosis : Measuring the ASO antibodies are useful for the diagnosis of
Rheumatoid Fever, Streptococcal infections etc .
Principle : The principle of this test is a based upon Immuno Turbidimetric method.
Features Benefits
• Quantitative estimation of ASO
• Calibrator included • Ready to use R1 and R2
• XL-System Pack Kits and T-LTX Reagents provided along with
Liquixx Kits the Kit
• Measuring range from 20 IU/ml - • XL-System Pack Kits for Fully
800 IU/ml Auto Analyzers and T-LTX Kits
• Additional Quality Controls for Semi Auto Analyzer to suit
• Longer shelf life of 24 months all type of customers.
ASO ASO
Make Linearity Method
10
11
Features Benefits
• Quantitative estimation of RF
• Calibrator included • It contains ready to use R1
• XL-System Pack Kits and T-LTX Liquixx Kits and R2 Reagents
• Measuring range from 6 IU/ml - 160 IU/ml • XL-System Pack Kits for
• Additional Quality Controls Fully Auto Analyzers and
• Longer shelf life of 24 months T-LTX Kits for Semi Auto
Analyzers to suit all type
of customers.
Normal range up to 20 IU/mL
12
RF RF RF
Make Linearity Method
TbM provides 24 Months Shelf Life of the RF which is higher than Competitors
13
14
Features Benefits
• Quantitative estimation of CRP • Ready to use R1 and R2
• Calibrator is included Reagents
• XL-System Pack Kits and T-LTX Liquixx Kits • XL-System Pack Kits for Fully
• Measuring range from 2 mg/L -65 mg/L Auto Analyzers and T-LTX
• Additional Quality Controls Kits for Semi Auto Analyzer
• Longer shelf life of 24 months to suit all type of customers.
15
16
Principle :The Principle of the Kit is modified PVS (polyvinyl sulfonic acid) &
PEGME(polyethyleneglycol methyl ether) Plus Selective detergent method.
Features Benefits
• Quantitative estimation of Direct HDL Cholesterol
• Calibrator included • No Precipitation required.
• Measuring range from 1.9 mg/dl – 193 mg/dl • True Direct HDL value
• 24 months shelf life without any interferences.
• Ready to use R1 and R2
Reagents
• XL-System Pack Kits for Fully
Auto Analyzers and Liquixx
Kits for Semi Auto Analyzers
The normal range for Adults male: 35.3 mg/dl –
79.5 mg/dl; Adults female: 42.0 mg/dl – 88.0 mg/dl
18
Clinical Significance : Direct Low Density Lipoproteins (LDL) are synthesized in the liver by the
action of various lipolytic enzymes on triglyceride-rich Very Low Density Lipoproteins (VLDLs).
Disease Diagnosis : Direct LDL cholesterol is a key factor in the pathogenesis of atherosclerosis
and Coronary Artery Disease (CAD)
Principle :The Principle of the Kit is modified PVS(polyvinyl sulfonic acid) &
PEGME(polyethyleneglycol methyl ether) Plus Selective detergent method.
Usage : Direct LDL Kit is tested in Hospital Laboratories, Laboratory Chains, Individual
Laboratories,Cardiac Hospitals and Clinics ,Nursing Homes, etc.
20
Features Benefits
• Quantitative estimation of Direct LDL Cholesterol • No calculation required.
• Calibrator included • True Direct LDL value
• Measuring range from 2.60 mg/dl – 263 mg/dl without any
• 24 months shelf life interferences.
• Ready to use R1 and R2
Reagents
• XL-System Pack Kits for
Normal range of Direct LDL Cholesterol is Less than 100 Fully Auto Analyzers and
mg/dl – optimal;100 – 129 mg/dl – near/above optimal; Liquixx Kits for Semi Auto
130 – 159 mg/dl – borderline high; 160 – 189 mg/dl – high; Analyzer to suit all type
≥190 mg/dl – very high of customers.
21
22
23