Title 1
ADMINISTRATIVE
Chapter 1.01
GENERAL PROVISIONS
SECTION 1.01.02: Declaration of Policy
(b) Railings. Railings shall be built substantially and should be at least 1.00
meter (3 feet, 3 inches) in height.
(c) Fence. Fences shall be built of an approved material, not less than 2.40
meters (8 feet) in height above grade, and to be placed on the side of the
walkway nearest to the building site. Fences shall enclose entirely the building
site. Openings in such fences shall be provided with doors which shall be kept
closed at all times.
(d) Canopies. The protective canopy shall have a clear height of 2.40 meters (8
feet) above the walkway, and shall be constructed structurally safe. Every
canopy shall have a solid fence built along its entire length on the construction
side. If materials are stored or work is done on top of the canopy, the edge
along the street shall be adopted by a tight curb board not less than 30
centimeters (1 foot) high and a railing not less than 1.00 meters (3 feet, 3
inches) high shall be provided. The entire structure shall be designed to carry
the loads imposed upon it: Provided, That the live load shall be not less than
633 kilograms per square meter (150 pounds per square foot).
TITLE 7 - ENGINEERING
REGULATIONS
Chapter 7.01 - GENERAL
DESIGN REQUIREMENTS
SECTION 7.01.01: Scope
(a) The design and construction of all
buildings and structures shall be in
compliance with the provisions of the
National Structural Code for Buildings,
latest edition, adopted and promulgated
by the Board of examiners of civil
engineers pursuant to Republic Act
Numbered 544, as amended, otherwise
known as the "Civil Engineering Law".
TITLE 8 - DETAILED
REGULATIONS
Chapter 8.01 - GENERAL
REQUIREMENTS
SECTION 8.01.02: Excavations,
Foundations, and Retaining Walls
Excavation or fills for any building structure and
excavations or fills accessory thereto shall be so
constructed or protected that they do not
endanger life and property.
Whenever or wherever there exists in the site of
the construction on abrupt change in the ground
levels or levels of the foundation such that
instability of the soil could result, retaining walls
shall be provided and such shall be of adequate
design and type of construction in accordance
with generally accepted standards and principles
of engineering.
SECTION 8.01.07: Stairs, Exits,
and Occupant Loads
Exit Requirements. Exit requirements of a building or portion
thereof used for different purposes shall be determined by the
occupant load which gives the largest number of persons. No
obstruction shall be placed the required width of an exit except
projections permitted by this code.
Number of Exits. Every building or usable portion thereof shall
have at least one exit. In all occupancies, floors above the first
story having an occupant load of more than 10 shall have not less
than two exits. Every story or portion thereof, having an occupant
load of 500 to 999 shall have not less than three exits. Every story
or portions thereof, having an occupant load of 1000 or more shall
have not less than four exits.
Width. The total width of exists in meters shall be not less than the
total occupant load served divided by 165 (in feet, by 50). Such
width of exits shall be divided approximately equally among the
separate exits.
Chapter 10.06 - SIGNS
SECTION 10.06.01: General
(a) No signs or signboards shall be erected
in such a manner as to confuse or obstruct
the view or interpretation of any official
traffic sign signal or device.
(b) No signboards shall be constructed as
to unduly obstruct the natural view of the
landscape, distract or obstruct the view of
the public as to constitute a traffic hazard,
or otherwise defile, debase, or offend the
aesthetic and cultural values and
traditions of the Filipino people.