Вы находитесь на странице: 1из 3

4G L1800-L900 Transition

Telkomsel
November, 2015
Idle Mode Transition

Measurement Trigger R Selection Criteria :


IntraFreq Meas = -68 dBm Rn > Rs (Q meas N- qoffset N > Q meas S + qHyst)
sIntrasearch = 62 dB qHyst=3dB
qrxlevminintraF = -130dBm qoffCell=0 dB

6 LTE 1800 LTE 1800 LTE 1800

Measurement Trigger R Selection Criteria : R Selection Criteria :


InterFreq Meas = -105 dBm Rn > Rs (Q meas N- qoffset N > Q meas S + qHyst Measurement Trigger
InterFreq Meas = -110 dBm Rn > Rs (Q meas N- qoffset N > Q meas S + qHyst
sNonIntrsearch = 25 dB qHyst=3dB qHyst=3dB
qrxlevmininterF = -130 dBm qoffCell=0 dB sNonIntrsearch = 20 dB
qrxlevmininterF = -130 dBm qoffCell=0 dB
qoffFrq= 8 (-8 dB) qoffFrq= 21 ( 6 dB)

6 LTE 900 LTE 900

Measurement Trigger R Selection Criteria :


IntraFreq Meas = -68 dBm Rn > Rs (Q meas N- qoffset N > Q meas S + qHyst)
sIntrasearch = 62 dB qHyst=3dB
qrxlevminintraF = -130dBm qoffCell=0 dB
Dedicated Mode Transition
A3 Better Cell Handover: A5 Coverage Handover
N > S + a3Offset threshold3 = 28 ( -112 dBm )
enableBetterCellHo = 1 (True) threshold3a = 29 ( -111 dBm)
Handover Measurement Trigger a3Offset = 6 (3 dB) a5TimeToTrigger = 8 (320 ms)
threshold1= 75 = -65 dBm a3TimeToTrigger = 8 (320 ms) a5ReportInterval = 3 (640 ms)
threshold2a = 45 = -95 dBm a3ReportInterval = 3 (640 ms)

6 LTE 1800 LTE 1800 LTE 1800

Handover Measurement Trigger A3 Better Cell Handover:


actIfHo = 1 ( True) N > S + a3OffsetRsrpInterFreq Handover Measurement Trigger A3 Better Cell Handover:
threshold2InterFreq = 36 (-104 dBm) a3OffsetRsrpInterFreq = -40 = -4 dB actIfHo = 1 ( Enabled) N > S + a3OffsetRsrpInterFreq
a3TimeToTriggerRsrpInterFreq = 8 = 320 ms threshold2InterFreq = 30 (-110 dBm) a3OffsetRsrpInterFreq = 80 = 8 dB
a3ReportIntervalRsrpInterFreq = 1 = 240 ms a3TimeToTriggerRsrpInterFreq = 8 = 320 ms
a3ReportIntervalRsrpInterFreq = 1 = 240 ms

6 LTE 900 LTE 900

A3 Better Cell Handover: A5 Coverage Handover


Handover Measurement Trigger
N > S + a3Offset threshold3 = 28 ( -112 dBm )
threshold1= 75 = -65 dBm
enableBetterCellHo = 1 (True) threshold3a = 29 ( -111 dBm)
threshold2a = 45 = -95 dBm
a3Offset = 6 (3 dB) a5TimeToTrigger = 8 (320 ms)
a3TimeToTrigger = 8 (320 ms) a5ReportInterval = 3 (640 ms)
a3ReportInterval = 3 (640 ms)