Вы находитесь на странице: 1из 13

Final Project Presentation

• On Monday, same classroom at noon

• PowerPoint (5 minutes presentation)


• Upload the file before the class

• Approximately 6-7 slides (a minute per slide)


• Problem introduction
• Model development - specific problem
• Results
• Results
• Discussion
• Conclusions
Manufacturer data
• http://www.titus-hvac.com/ecatalog/subcategory.aspx?refid=37&subref=130
• http://www.mestek.com/company-directory.asp#.U1_bi1dkW1c
• http://www.price-hvac.com/Catalog/Section_F1/CatalogData.aspx
• http://www.krueger-hvac.com/
• http://www.trane.com/commercial/north-america/canada/en/products-systems/equi
pment/air-handlers/packaged-climate-changer-LPC.html
• http://www.johnsoncontrols.com/content/us/en/products/building_efficiency/produ
cts-and-systems/integrated_hvac_systems/Industrial___Commercial_HVAC_Equip
ment/airside_products/york_custom_ahus.html
• http://www.lennoxcommercial.com/products/packaged-rooftop-units/

• …….
VAV repeaters:
http://www.nailor.com/onlineCatalog09/CAT-06/CATBSD.pdf ETL models
http://www.dhtcoils.com/?gclid=CPus9rO8wMkCFRCGaQodfqUCXw
Objectives
Learn about

1) Control for HVAC systems


- Economizers (Psychrometrics) and control
- Heat recovery systems (Psychrometrics)

2) Some advance HVAC systems


desiccant, enthalpy, sensible wheel
Economizer
Economizer (fresh air volume flow rate control)

Controlled device is damper

fresh
damper
air
- Damper for the air

- Valve for the CC


mixing

recirc.

air

T & RH sensors
Economizer – cooling regime
How to control the fresh air volume flow rate?
If TOA < Tset-point → Supply more fresh air than the minimum required

% fresh air
The question is how much?

100%

Open the damper for the fresh air

Minimum for
and compare the Troom with the Tset-point .
ventilation

Open till you get the Troom = Tset-point

If you have 100% fresh air and your

still need cooling use cooling coil.


Sensible and Enthalpy and
Desiccant wheels
Sensible and Enthalpy Wheels
Heat recovery system in
NMS building at UT
Sensible Enthalpy
Desiccant wheel

»Figure 3 – A desiccant-based cooling system combined with regenerative heat exchanger, vapor compression cooling, and evaporative
humidifier (hybrid system).
Commercial HVAC Systems

Single zone Multi zone

All Hydroinic
VAV CAV
CAV VAV
that relay on

infiltration

With and
With and Dual
Dual
without With DOAS with
without duct
duct
humidity reheaters fan coils
reheaters
control
DOAS with

fan coils

This is not the complete list ! or radiant


Residential System
Residential vs. Commercial systems
• Course focus was on HVAC equipment that is
used in both: residential and commercial
systems

• Emphasize on the application in commercial


systems
Course objectives
• Apply fundamental physical principles to HVAC
design
• Describe and size each component in an HVAC
system
• Design HVAC systems based on manufacturer’s
datasheets
• Contrast residential systems with commercial
systems and use appropriate design techniques for
each type of system
• Solve HVAC design problems with high-quality
references