Basic ControlNet:

I/O for Logix

May 2011

(Confidential – For Internal Use Only)

Copyright © 2009 Rockwell Automation, Inc. All rights reserved.

1
Objective

At the end of this module the student will be able to articulate the
ControlNet product portfolio for I/O.

And more importantly you will learn what I/O is supported by what
controller and scanner.

Terms covered: in-cabinet I/O, on-machine I/O, and chassis-based I/O,


conformal coating

(Confidential – For Internal Use Only) Copyright © 2009 Rockwell Automation, Inc. All rights reserved. 2
Types of categories of ControlNet product

• Media
• Controllers
• I/O
• Drives
• Operator Interface/HMI
• Linking Devices (Bridges)
• Network Services

(Confidential – For Internal Use Only) Copyright © 2009 Rockwell Automation, Inc. All rights reserved. 3
Previously we focused on the Controller &
its Scanner
Local I/O Modules

ControlLogix Controller
1756-CNBR as a
ControlNet Scanner

Now the focus will


be ControlNet
1756-CNBR as a
ControlNet Adapter
remote I/O

Remote I/O Modules

(Confidential – For Internal Use Only) Copyright © 2009 Rockwell Automation, Inc. All rights reserved. 4
ControlNet I/O Platforms

In-Cabinet (IP20)
distributed I/O requires
an enclosure for
environmental
protection.

Shown: Upper Flex I/O


Lower Point I/O

(Confidential – For Internal Use Only) Copyright © 2009 Rockwell Automation, Inc. All rights reserved. 5
In-Cabinet ControlNet I/O

• 1734 POINT I/O


1734-ACNR adapter (redundant)
• 1794 FLEX I/O
1794-ACN15 adapter
1794-ACNR15 adapter (redundant)
1794-ACN15K adapter, conformal coated
1794-ACNR15K adapter (redundant), conformal coated
• 1794 FLEX I/O XT
1794-ACNR15XT adapter (redundant), conformal coated, extreme environ.
• 1797 FLEX Ex Intrinsically Safe I/O
1797-ACNR15 adapter (redundant)
1794-ACN15 adapter (use with 1797-BIC and 1797-CEC to connect to
hazardous areas)
1794-ACNR15 adapter (redundant; use with 1797-BIC and 1797-CEC to
connect to hazardous area)

(Confidential – For Internal Use Only) Copyright © 2009 Rockwell Automation, Inc. All rights reserved. 6
1734 Point I/O – Adapter on left, I/O Modules
on right
Adapter

I/O

I/O
(Confidential – For Internal Use Only) Copyright © 2009 Rockwell Automation, Inc. All rights reserved. 7
1794 Flex I/O – Adapter on left, I/O Modules
on right
Adapter

I/O

(Confidential – For Internal Use Only) Copyright © 2009 Rockwell Automation, Inc. All rights reserved. 8
1797 Flex Ex I/O – Adapter on left, I/O
Modules on right

Adapter

I/O
(Confidential – For Internal Use Only) Copyright © 2009 Rockwell Automation, Inc. All rights reserved. 9
FLEX-XT Product Overview – Note the limited
number of modules are available.

Extreme temperature range


-20 °C to + 70 °C

Terminal Bases and Cables


Meet Logix-XT control platform
requirements.
FLEX-XT Products
1794-ACNR15XT CNET Adapter for FLEX I/O
Standard FLEX-XT Benefits 1794-IB16XT
1794-IE4XOE2XT
24VDC 16 Channel Discrete Input Module
Analog, 4IN/2out, XTEMP (-20C to 70C)
Wiring savings, cost-effectiveness 1794-IB10XOB6XT 24VDC 10 Channel Discrete Input with / 6 Channel
Discrete Output Module
and flexibility in communication, 1794-OB8EPXT 24VDC 8 Channel Discrete Electronically Protected
mounting, and I/O type 1794-OB16PXT
Output Module
24VDC 16 Channel Discrete Output Module
1794-OW8XT 8 Channel Relay Output Module
1794-IE8XT 8 Channel 16 Bit Analog Input Module
1794-IF4IXT 4 Channel 16 Bit Isolated Analog Input Module
1794-IF2XOF2IXT 2 Channel 16 Bit Isolated Analog Input
with 2 Channel 16 Bit Isolated Analog Output Module
1794-OF4IXT 4 Channel 16 Bit Isolated Analog Output Module
1794-IJ2XT 2 Channel Counter Module
1794-IRT8XT 8 Channel RTD/Thermal Couple Input Module
1794-IR8XT ANALOG, RTD 8 INPUT MODULE, XTEMP
1794-OE4XT ANALOG, 12BIT, 4OUT, XTEMP (-20C to 70C)

(Confidential – For Internal Use Only) Copyright © 2009 Rockwell Automation, Inc. All rights reserved. 10
ControlNet I/O Platforms

On-Machine
(IP67)
distributed I/O
does not require
an additional
enclosure,
allowing for
easier
maintenance.

Shown: Yellow cables


attach to Armor I/O
on a rotary filler
machine
(Confidential – For Internal Use Only) Copyright © 2009 Rockwell Automation, Inc. All rights reserved. 11
On-Machine ControlNet I/O

• 1738 ArmorPoint I/O


1738-ACNR adapter with TNC Connector (redundant)

(Confidential – For Internal Use Only) Copyright © 2009 Rockwell Automation, Inc. All rights reserved. 12
1738 Armor Point I/O – Adapter on left, I/O
Modules on right
Adapter I/O

Adapter

Adapter I/O Bases


(Confidential – For Internal Use Only) Copyright © 2009 Rockwell Automation, Inc. All rights reserved. 13
ControlNet I/O Platforms

Chassis-based I/O (IP20) is


specifically designed for a particular
processor, as part of its family.

Chassis-based I/O systems are also


capable of being mounted away
from the controller via networks.

Its IP20 rating means it requires an


enclosure.

(Confidential – For Internal Use Only) Copyright © 2009 Rockwell Automation, Inc. All rights reserved. 14
Chassis-based I/O ControlNet I/O

• 1756 ControlLogix I/O


1756-CN2
1756-CN2R (redundant)
1756-CNB
1756-CNBR (redundant)
The ControlLogix controller has the base catalog number of 1756.

• 1771 PLC-5 I/O ….Can be used with Logix.


1771-ACN15
1771-ACNR15 (redundant)
The PLC-5 has a base catalog number of 1785.

(Confidential – For Internal Use Only) Copyright © 2009 Rockwell Automation, Inc. All rights reserved. 15
1756 I/O – Adapter anywhere, I/O Modules
anywhere

I/O

Removable
Terminal Block
which you can
buy pre-wired!
Adapter
(Confidential – For Internal Use Only) Copyright © 2009 Rockwell Automation, Inc. All rights reserved. 17
1771 I/O – Adapter on the left , I/O to the
right

Adapters

I/O

4 chassis
sizes, much
taller than
1756 or 1746
(Confidential – For Internal Use Only) Copyright © 2009 Rockwell Automation, Inc. All rights reserved. 19
What ControlNet I/O does each controller
support?
PLC-5 on ControlNet; 5/20, 5/40 and 5/80
and
SLC on ControlNet; 5/02, 5/03, 5/04, 5/05
• I/O adapters supported
– 1734, 1738,1747,1771, 1794, 1797
– NO 1756 support
PLC-5 or SLC can not control remote 1756
I/O via ControlNet.

Logix on ControlNet
• I/O adapters supported
– 1734, 1738,1771, 1794, 1797
– NO 1746 I/O support with 1747
adapter Logix can not control remote 1746
I/O via ControlNet.