INTRODUCTION
Group D – Assembly Buildings

• Include any building or part of a building, where not less than 50 persons
congregate or gather.
• Purposes of amusement, recreation, social, religious, patriotic, civil, travel
and so on.

• Examples:- Theatres, motion picture houses, assembly halls , auditoria ,


gymnasiums, restaurants ,places of worship, dance halls, club rooms,
passenger stations and stadia.
3
ASSEMBLY BUILDINGS
Buildings under Group D shall be further subdivided as follows:

• Subdivision D-1:-Buildings having a theatrical or motion picture


accomodating over 1000 persons.
• Subdivision D-2:-Buildings having a theatrical or motion picture
accomodating up to 1000 persons.
• Subdivision D-3:- Buildings without a permanent stage
accommodating 300 or more persons.

4
ASSEMBLY BUILDINGS
• Subdivision D-4:-Buildings without a permanent stage
accommodating less than 300 persons.

• Subdivision D-5:-All other structures not covered by D-1 to D-4.

• Subdivision D-6:-Mixed occupancies of assembly and mercantile.

• Subdivision D-7:-Underground and elevated mass rapid transit system

5
DETAILS OF SITE
• Location :- College Playground , College of Engineering,
Sreekaryam , Trivandrum -16.

• Area of site :- 3000 square metres (approximately)

6
LOCATION MAP

7
SITE PLAN

8
SETBACKS REQUIRED

• Floor area of the building exceeds 800 sq. metres,

• Open yard spaces required to be left out as per Kerala Municipal


Building Code (KMBC) :

 Front yard : 6 metres (minimum)


 Side yard (each side ) : 1.5 metres (minimum)
 Rear yard : 1.5 metres (minimum)
9
NBC REQUIREMENTS
• Main entrance to plot is of adequate width – 6 metres.
• Facilitates easy access to the fire engine.
• Entrance gate shall fold back against the compound wall.
(Ensures conformation with Part 3 clause 4.6 (d) of NBC)

• The building is grouped under subdivision D-2 as per the


specifications of NBC.

10
USER REQUIREMENTS
• Box office
• Viewing room ( seating capacity – 700 people)
• Projector room
• Toilet – Gents
• Toilet – Handicapped
• Toilet – Ladies

11
USER REQUIREMENTS
• Office room
• Service room
• Food Counter
• Stairs
• Ramp
• Parking
• Lobby

12
THEATRE SEATING
• Total – 700 seats.
• Number of rows – 19
• Seats in each row – 41
• Thickness of a seat – 20 cm
• Width of a seat – 65 cm
• Length of seat – 50 cm
• Seat clearance – 50 cm
• Screen size – 22*9 m

13
LAYOUT OF THE THEATRE

14
OTHER REQUIREMENTS
Drinking water supply
• Requirement – 15 litres /seat/day
• Total requirement – 10,500 litres / day

Parking space
• Population of Trivandrum city – 9.58 lakhs (2011 survey)
• Parking space required for 28 cars
• Additional 25 to 50 % area for two wheelers

15
OTHER REQUIREMENTS
Toilets
Public Strength No.of water No.of No.of wash Ablution
closets urinals basins taps
Male 467 5 18 3 5
Female 233 5 2 4

Staff Strength No.of water No.of No.of Wash Ablution


closets urinals basins taps
Male 15 2 2 2 2
Female 12 2 2 2

16
TENTATIVE LAYOUT OF THE BUILDING

17
FIRE SAFETY MEASURES
Portable fire extinguisher
• 1 per 100 seats.
• Total – 7 extinguishers
• Gap between each – 15 m.

Rackets on wall
• 1.2 m from floor level
• Placards printed above them

18
FIRE SAFETY MEASURES
Automatic fire alarm system
• Enabled at auditorium , corridor , canteen and storage spaces.

Fire fighting tank


• Storage tank – 50,000 litres
• Replenishment system – 1000 lit/min pipe
• Suitable no. of manholes

19
CONCLUSION
• User requirements have been identified
• Building site has been identified
• The required setbacks and access have been found.
• Tentative plan of the theatre was drawn.

20
REFERENCES
• National Building Code,2016
• Kerala Municipal Building Rules,1999
• IS – 4878-1986 ,Byelaws for construction of cinema buildings
• Dolby.com