Академический Документы
Профессиональный Документы
Культура Документы
STEAM GENERATOR
Generate steam at desired rate at desired pr and temp by burning fuel in furnace. Controlled circulation with Rifled Tubing, Dry bottom, Radiant Reheat, Single drum,Top Supported, Balanced draft furnace & Tilting tangential firing Designation : 19177 16115 291-51 CC + 245-51
Consists furnace, superheater, reheater, water tubes or evaporators, economiser and air-preheater.
Consists of various auxilliaries such as Feeders, bunkers, Pulverizers, burners, ESP, Fans, ash-handling equipments and chimney.
Steam power plants operate on modified Rankine Cycle, DM water as working fluid. Sensible heat is added in economiser +furnace Steam generation takes place in waterwall. Superheating takes place at superheaters. Heat transfer in furnace and enclosed superheater takes place thru radiation.
RH IPT
LPT LPH
CEP
condenser
BOILER COMPONENTS
Economizers Boiler drum Water wall Superheaters (LTSH, DPSH, Platen) Re-heaters Safety Valves Wind Box & Air Dampers: SADC, FAD Etc. Burners Air pre-heaters Boiler Supporting Structures
M.S
C.R.H
H. R. H
500mw
FROM F.R.S BOTTOM RNG HDR & Z-PANEL 1ST PASS W.W O/L HDRS 1ST PASS W.W
ROOF I/L HEADER 2nd PASS LOWER C-HDRS LTSH O/L HEADER D.P.O/L HEADER R.H.HEADER ECONOMISER
2ND PASS UPPER C-HDR LTSH I/L HEADER D.P.I/L HEADER S.H. HEADER 2ND PASS ROOF O/L HDR(REAR
DPSH
LTSH
364C
1300-1400
ECO
323C
251.8C
1400C
APH
ID fan
ESP
FLOW OF AIR
TOTAL AIR
SA 60-70%
PA 30-40%
COLD SA
APH HOT SA
COLD PA
MILL
LTSH
ECO
CHIMNEY
1400C
SAPH (2)
Fuel+Air
PAPH (2)
ESP
ID FAN
1118C
1016C
837C
538C
1300-1400
332C
ECO
O2 = 3.6%
1400C
APH
131-136C ID fan
ESP
HEAT DISTRIBUTION
Heat gained by Boiling water 38% Heat gained by Superheater& Reheater 38%
Loss due to moisture in air. Loss due to moisture in fuel. Loss due to combustion generated moisture. Dry Exhaust Gas Losses~ 4.5%
Furnace
Hot gas
Flue gas
BOILER EFFICIENCY
Direct method
Steam Output
Flue Gas
Boiler
Efficiency =
Steam flow rate *(steam enthalpy-feed water enthalpy) Boiler Efficiency= +steam flow rate in RH*Heat added in RH *100 Fuel firing rate*Gross calorific value
Water
Indirect method
Steam Output
6. Surface loss
1. Dry Flue gas loss 2. H2 loss 3. Moisture in fuel 4. Moisture in air 5. CO loss
Boiler
Air
7. Bottom ash loss
EFFICIENCY
Dry Gas : 4.163 %
Moisture in fuel
H2 in fuel H2O in Air Unburnt Carbon Radiation Sensible heat losses Unaccounted
: 2.656 %
: 5.635 % : 0.108 % : 1.50 % : 0.110 % : 0.585 % : 0.176 %
Efficiency = 85.47%
291-51 CC + 245-51
Fuel Heat input: 1224.8 x 106 KCal/hr. Main Steam pr & temp: 177.5kg/cm2 & 540C Reheat Steam pr & temp: 41.09kg/cm2 & 568C
CONTD
Total air flow Total heating surface area Superheater Reheater Economiser : 2013 t/h :12083 m2 : 9250 m2 : 9000 m2
Minimum load at which steam generator can be : 30% BMCR operated continuously with complete flame stability without oil support Minimum load at which steam generator can be : 20% BMCR operated continuously with complete flame stability with oil support when firing coal Maximum continous output with one FD fan and one ID fan in operation : 60% BMCR