Вы находитесь на странице: 1из 36

UNIVERSIDAD NACIONAL DE PIURA

FACULTAD DE INGENIERIA DE MINAS


TEMA : VENTILACION DE LA MINA RAURA
Zambrano Hurtado Gloria Ramos Garca Jose Luis Lpez Ramrez Juan Carlos
Merino Carhuachinchay Jhermain Ojeda Carrin Keber

INTEGRANTES

PROFESOR

: ING. JOSE CHANG VALDIVIEZO.

MINA RAURA: UBICACION

UBICACIN Y ACCESO
UBICACION: Raura Oyn

Cerro de Pasco Distrito: San Miguel de Cauri


Provincia: Lauricocha

Lima

La Oroya

Dpto: Hunuco ALTITUD: 4,700 m.s.n.m. ACCESO: 1- Huacho-Sayn-Oyn-Raura 2- Hunuco-Jess-Cauri-Raura 3- Pasco-Oyn-Raura

CA. MINERA RAURA S.A. RECIBI EN DICIEMBRE DEL 2005 LA CERTIFICACIN INTERNACIONAL EN ISO14001 (AUDITORA INTERNACIONAL BUREAU VERITAS) LA AUDITORIA INTERNACIONAL DE OHSAS SE REALIZARA EN EL MES DE OCTUBRE DEL 2006 SE ASEGURA QUE NUESTROS PROCESOS Y NUESTRAS OPERACIONES CUMPLEN CON LOS ESTNDARES INTERNACIONALES DE SEGURIDAD Y CALIDAD AMBIENTAL

INTRODUCCION
LA UNIDAD MINERA RAURA, DE PROPIEDAD DE LA CA. MINERA RAURA S.A. INICI SUS OPERACIONES EN 1960. ESTAS OPERACIONES SE EJECUTARON MEDIANTE LABORES SUBTERRNEAS CON PRODUCCIN DE MINERAL POLIMETLICO ACTUALMENTE, CA. MINERA RAURA S.A., ES UNA EMPRESA PERUANA DE LA MEDIANA MINERA, DEDICADA A LAS ACTIVIDADES MINERO METALRGICAS DE EXPLOTACIN, BENEFICIO Y COMERCIALIZACIN DE CONCENTRADOS DE MINERALES POLIMETLICOS (ZINC, PLATA, COBRE Y PLOMO).

LOS MTODOS DE EXPLOTACIN SON: SHIRINKAGE, CORTE Y RELLENO ASCENDENTE (BREASTING Y TALADROS INCLINADOS), CMARAS Y PILARES, BLOCK CAVING (TALADROS LARGOS).
COMPAA MINERA RAURA S.A. BUSCA DESARROLLAR UN SISTEMA DE VENTILACIN PTIMO QUE BRINDE UN AMBIENTE SEGURO , SALUDABLE Y CMODO AL PERSONAL EN INTERIOR MINA COMPAA MINERA RAURA S.A. BUSCA LOGRAR AHORROS EN SUS COSTOS DE OPERACIN REFERENTE A VENTILACIN EN UNA MINA COMO RAURA NO SE PUEDE LOGRAR BUENOS RESULTADOS EN VENTILACIN SINO SE CUENTA CON LOS EQUIPOS Y LA INFRAESTRUCTURA ADECUADOS, EL DIRECCIONAMIENTO Y VOLUMEN DE AIRE REQUERIDO SE DEBE LOGRAR CON AYUDA DE VENTILACIN MECNICA

PLANO ISOMETICO - RAURA

CIRCUITO DE VENTILACION PRIMARIO


INGRESO DE AIRE A CATUVA
Nv 300 (SHUCSHAPAJ) INGRESA AIRE Nv 380 (TINQUICOCHA) INGRESA AIRE Nv 590 (HIDRO) INGRESA AIRE Nv 630 (CATUVA) INGRESA AIRE Nv 700 (CATUVA) INGRESA AIRE

CIRCUITO PRIMARIO CATUVA

CIRCUITO DE VENTILACION PRIMARIO


SALIDA DE AIRE CATUVA
Nv 630, RB 66 Nv 630, RB 69 Nv 630, RB 70 Nv 630, RB 02 Nv 630, RB 23 Nv 630, RB 10 Nv 700, RB 09

BALANCE DE AIRE PARA MINA CATUVA


NECESIDADES DE AIRE PARA CATUVA
POR LA CANTIDAD DE HOMBRES POR GUARDIA 148 hombres x 6.0 m3/min 888.00 m3/min POR EL USO DE EQUIPO DIESEL 1681.50 HP x 3.0 m3/HP/min 5,044.50 m3/min POR EL USO DE EXPLOSIVOS 25.0 m/min x 8 Nv x 11.11 m2 2,222.00 m3/min
TOTAL 8,154.50 m3/min 287,972.90 CFM

BALANCE DE AIRE PARA MINA CATUVA


INGRESO DE AIRE ( ANTES )
LUGAR DE INGRESO m3/min CFM

Nv 300, Cx 575
Nv 380, Cr 080 SW Nv 380 Nv 590, Cr 070 SW Nv 590 RB Nv 590, Gl 480 Nv 630, Cx 230 SW Nv 700 TOTAL

1,534.91
594.45 199.32 528.96 140.99 86.14 2,062.54 114.94 5,262.25

54,204.73
20,992.78 7,038.91 18,680.01 4,979.00 3,041.99 72,837.77 4,059.06 185,834.25

BALANCE DE AIRE PARA MINA CATUVA


INGRESO DE AIRE ( DESPUES )
LUGAR DE INGRESO Nv 300, Cx 575 Nv 380, Cr 080 SW Nv 380 Nv 590, Cr 070 SW Nv 590 RB Nv 590, Gl 480 Nv 630, Cx 230 SW Nv 700 TOTAL m3/min 2,944.75 594.45 199.32 1,529.11 140.99 86.14 3123.35 114.94 8,733.27 CFM 104,000.50 20,992.78 7,038.91 54,000.00 4,979.00 3,041.99 110,300.00 4,059.06 308,412.24

RESUMEN BALANCE DE AIRE CIRCUITO PRINCIPAL CATUVA


INGRESO DE AIRE CFM NECESIDAD DE AIRE CFM COBERTURA
% ANTES DE INSTALAR VENTILADORES DESPUES DE LA INSTALACION DE VENTILADORES

OBSERVACION

185,834.25

287,972.90

64.50

308,412.24

287,972.90

107.10

- LAS CORRECCIONES HECHAS AL CIRCUITO PRINCIPAL:

INCREMENTO DE CAUDAL DE AIRE DE 185,834.25 CFM A 308,412.24 CFM


- SE LOGRO INSTALANDO 02 VENTILADORES DE 100,000 CFM Y

01 VENTILADOR DE 50,000 CFM, AS COMO EL MEJORAMIENTO DE PUERTAS Y TAPONES DE VENTILACION


- CON ESTA CORRECCION EL SISTEMA DE VENTILACION

CUMPLE CON LA NECESIDAD DE AIRE REQUERIDO EN MINA CATUVA

PUERTA DE VENTILACION

VENTILACION SECUNDARIA

- PARA LOS CIRCUITOS SECUNDARIOS, LUEGO DE LA

EVALUACION SE DETERMINO COMPLETAR LAS PREPARACIONES EN LAS LABORES DE EXPLOTACION


- LA CONSTRUCCION DE DUCTOS METALICOS PARA ELIMINAR

CAIDAS DE PRESION EN LOS CODOS


- EL USO DE MANGAS DE VENTILACION CON LOS DIAMETROS

APROPIADOS
- PARA LABORES MAYORES A 60.0 m DE LONGITUD SE

INSTALAN VENTILADORES EN SERIE GENERALMENTE CADA 100.0 m (DEPENDIENDO DE LA CAPACIDAD DEL VENTILADOR)

VENTILADOR SECUNDARIO

DISTRIBUCION Y COSTO DE VENTILACION ANTERIOR


VENTILADOR MOTOR (Kw) FACTOR (horas) CAPACIDAD (CFM) Kw-h $/Kw-hora $/dia $/ao UBICACIN

VMR-12 VMR-13 VMR-14

75.00 11.25 95.25

1.0 1.0 0.8

50,000 8,000 50,000

1800.00 270.00 1714.50

0.045 0.045 0.045

81.00 12.15 77.15

29160.00 4374.00 27774.90

Nv 300 Nv 300, Tj 835 Nv 300,Cx 035

VMR-11
VMR-10 VMR-09 VMR-05 VMR-06 VMR-08 VMR-03 VMR-04 VMR-01

22.50
24.00 11.25 37.50 15.00 15.00 41.25 34.50 191.25

1.0
1.0 1.0 0.8 0.8 1.0 0.8 0.8 1.0

20,000
20,000 15,000 18,000 15,000 15,000 20,000 20,000 120,000

540.00
576.00 270.00 675.00 270.00 360.00 742.50 621.00 4590.00

0.045
0.045 0.045 0.045 0.045 0.045 0.045 0.045 0.045

24.30
25.92 12.15 30.38 12.15 16.20 33.41 27.95 206.5

8748.00
9331.20 4374.00 10935.00 4374.00 5832.00 12028.50 10060.20 74358.00

Nv 340, Rp 895
Nv 380, Cx 100 Nv 380, Cx 315 Nv 490, Cx 943 Nv 490, Cx 943 Nv 490 Nv 590, Cx 112 Nv 540, Tj 082 Nv 630

VMR-02
VMR-15 VMR-16 VMR-27

150.00
24.00 24.00 40.73

1.0
0.8 0.8 1.0

100,000
15,000 20,000 20,000

3600.00
432.00 432.00 977.40

0.045
0.045 0.045 0.045

162.0
19.44 19.44 43.98

58320.00
6998.40 6998.40 15833.88

Nv 630
Nv 630, Tj 990 Nv 740, Tj 130 Nv 440, COBRI

TOTAL

812.48

17870.4

804.1

255966.4

DISTRIBUCION Y COSTO DE VENTILACION ACTUAL


VENTILADOR MOTOR (Kw) FACTOR (horas) CAPACIDAD (CFM) Kw-h $/Kw-hora $/dia $/ao UBICACIN

VMR-12 VMR-13 VMR-09

75.00 11.25 11.25

1.0 1.0 1.0

50,000 8,000 15,000

1800.00 270.00 270.00

0.045 0.045 0.045

81.00 12.15 12.15

29160.00 4374.00 4374.00

Nv 300 Nv 300, Tj 835 Nv 380, Cx 315

VMR-06
VMR-08 VMR-03

15.00
15.00 41.25

0.8
1.0 0.8

15,000
15,000 20,000

270.00
360.00 742.50

0.045
0.045 0.045

12.15
16.20 33.41

4374.00
5832.00 12028.50

Nv 490, Cx 943
Nv 490 Nv 590, Cx 112

VMR-01
VMR-02 VMR-15 TOTAL

191.25
150.00 24.00 534.00

1.0
1.0 0.8

120,000
100,000 15,000

4590.00
3600.00 432.00 12334.50

0.045
0.045 0.045

206.55
162.00 19.44 555.05

74358.00
58320.00 6998.40

Nv 630
Nv 630 Nv 630, Tj 990

166284.90

VENTAJAS LOGRADAS
- SE REDUJO EL NUMERO DE VENTILADORES INSTALADOS DE

16 A 09, CON EL CONSIGUIENTE AHORRO DE ENERGIA


- SE DA MAS EFICIENCIA A LAS OPERACIONES DEBIDO A QUE

LOS TIEMPOS PARA VENTILACION SON MENORES


- DEBIDO A QUE SE CONSTRUYERON CHIMENEAS DE

VENTILACION EN LAS LABORES SE HACE POSIBLE EL USO DE ANFO


- EL AHORRO EN VENTILACION CALCULADO SOLO PARA

CATUVA ES: 89,681.58 US$/AO

VENTILACION SECUNDARIA RB-83 Y RB 79 NV 540 A 300 B BALILLA


NV-540 NV-490 RB-83
RB-79

NV-380

NV-300

PLANTA RB-83 NV 540 A 300 B. BALILLA


NV-300

NV-380

RB-83

NV-490

NV-540

SECCION RB-83 NV 540 A 300 B BALILLA


NV-540

NV-490

RB-83 LONGITUD =238.00 MTS CUERPO DE MINERAL


INCLINACION =-79

SUBNIVEL
NV-380

NV-300

VENTILACION SECUNDARIA

VENTILACION SECUNDARIA

CALIDAD DEL AIRE


- UN BUEN SISTEMA DE VENTILACIN REQUIERE TAMBIN EL

MONITOREO CONSTANTE DE VEHCULOS QUE INGRESAN A INTERIOR MINA, QUE LA EMISION DE GASES DE ESTOS VEHICULOS ESTE CONTROLADA
- LA CANTIDAD DE AIRE NO DEBE SER MENOR A 3.0 m3/min

POR CADA HP QUE DESARROLLEN LOS EQUIPOS


- LA CALIDAD DEL AIRE ESTA EN FUNCIN AL CONTENIDO DE

O2 (MAYOR A 19.5% VOLUMEN)


- PARA EL USO DE ANFO LA VELOCIDAD NO DEBER SER

MENOR A 25 m3/min
- LA EVALUACIN DEL CIRCUITO DE VENTILACIN SE

REALIZARA EN UN PERIODO MENOR A 06 MESES

CALIDAD DEL AIRE

MONITOREO SEMANAL DE CO

CONCLUSIONES:
- EL NUMERO DE PERSONAL EN CATUVA ES: EE OPEMISS SRL : 65 hombres EE MICONG SRL : 55 hombres AESA MINING : 13 hombres OTROS : 15 hombres HACEN UN TOTAL DE 148 hombres, REQUIRIENDO UN TOTAL DE

888.00 m3/min DE AIRE


- EN MINA CATUVA SE TIENEN EN OPERACIN EN INTERIOR MINA EN SIMULTANEO DURANTE EL TURNO:

SCOOPTRAMS : 06 und C BAJO PERFIL: 02 und CAMIONETAS : 13 und CAMIONES : 06 und VOLQUETES : 08 und EQ SERVICIOS : 02 und HACIENDO UN TOTAL DE 1681.50 HP Y REQUIRIENDO UN CAUDAL DE 5,044.50 m3/min DE AIRE

- EL PROBLE MA DE LA VENTILACION SE AGUDIZA DEBIDO A QUE LAS LABORES SE POLARIZAN - EL CIRCUITO PRIMARIO DE VENTILACION EN CATUVA ESTA

DISEADO PARA SUMINISTRAR AIRE A CADA LABOR DE LA MINA, PARA ELLO ES NECESARIO ORGANIZAR LA VENTILACION SECUNDARIA
- LAS LABORES DEBEN CUMPLIR SUS ETAPAS HASTA QUEDAR APTAS PARA SU EXPLOTACION, UNA BUENA PLANIFICACION DE LABORES AYUDARA A EVITAR FUTUROS PROBLEMAS DE VENTILACION - LAS CHIMENEAS DE VENTILACION QUE SON PARTE DEL CIRCUITO PRINCIPAL DE VENTILACION TAMBIEN PUEDEN SER USADAS COMO

CHIMENEAS DE SERVICIOS PARA LINEA ELECTRICA, TUBERIA DE RH. AGUA, AIRE COMPRIMIDO, ETC, Y DEBEN SER INDEPENDIENTES DE LAS LABORES QUE VENTILAN LOS TAJEOS

- EL CIRCUITO PRINCIPAL DE VENTILACION EN CATUVA SE

ALIMENTA DE AIRE LIMPIO POR 05 NIVELES DE LA MINA EL CUAL SE CONDUCE A LAS LABORES EN OPERACIN
- 02 NIVELES ALIMENTAN AIRE EN DESCENSO Y 03 NIVELES

ALIMENTAN AIRE ASCENDENTE


- TODO ESTE AIRE SE HACE LLEGAR AL Nv 540 DE LA MINA QUE

SE CONVIERTE EN EL CENTRO DEL SISTEMA DE VENTILACION Y DESDE ALLI SE EXTRAE CON 02 VENTILADORES DE 100,000 CFM A TRAVES DE RBs A SUPERFICIE
-

SE DEBE MANEJAR EL CONCEPTO DE INSTALAR VENTILADORES SECUNDARIOS SOLO EN LABORES DE AVANCE

BIBLIOGRAFIA

www.todoexpertos.com

www.arqhys.com/ventilacion-minas.
www.derenatura.com/elrinconminero

www.raura.com