2 Nokia Siemens Networks Presentation / Author / Date
For internal use Backup time 5-10 minutesBackup time 2.5 hours Backup time 3.6 hours !ower and backup soIution exampIes for 2G/3G Nokia FIexi BTS Sites Nokia Flexi power module Micro BBU with 3 kW rectifier and 62 Ah battery capacity Wall and pole mountable Nokia Flexi outdoor cabinet Nokia Flexi outdoor cabinet with MIBBU with MIBBU Nokia Flexi power Nokia Flexi power module module Micro BBU Micro BBU 3 Nokia Siemens Networks Presentation / Author / Date For internal use FIexi !ower ModuIe F!MA Example configuration from FPMA with: 3 Flexi Power AC/DC sub-modules FPAA (230VAC -> 48VDC) 1 Flexi Power Battery FPBA + - 48VDC output to BTS AC input cabling to FPMA AC feed to FPAA (3pcs) 4 Nokia Siemens Networks Presentation / Author / Date For internal use FIexi !ower Battery sub-moduIe F!BA Features Light weight / small size System Compatibility High Reliability sub-module No Periodical Maintenance No hazardous material for Environment Long life cycle Excellent discharge rate characteristics Advantage Space saving Less construction cost Easy handling and high safety Environment friendly High operational reliability Excellent battery performance Usable with any indoor/outdoor BTS Site Option to FIexi !ower ModuIe F!MA for WCDMA HSPA BTS GSM/EDGE BTS WiMax BTS any 48 VDC equipment 5 Nokia Siemens Networks Presentation / Author / Date For internal use OptionaI FIexi AC !ower ModuIe F!MA FPMA is AC/DC Power Module frame with 4 sub-module slots for rectifiers and batteries RF Module RF Module System module Power Module AC in DC Sector 2 Sector 3 FPMA with FPAA FPBA AC in DC A C Flexi Power AC/DC rectifier FPAA 1 kW DC power per FPAA B Optional Flexi Power Battery FPBA 5-10 minutes for 2+2+2 (1*FPBA) B A C Example configuration for 2+2+2 2 x FPAA (AC/DC rectifiers) 2 x FPBA (Lithium-on batteries) About 15 minutes back up FPAA supports voltage range 184 . 276 VAC FPAA supports voltage range 0 . 276 VAC with FPBA FPF System ModuIe * RF Module Sector 1 6 Nokia Siemens Networks Presentation / Author / Date For internal use FIexi AC !ower ModuIe usage aIternative x Big back up time: -No additional cabinet - Space, constructions, time, crane, work etc savings Back up solution for Remote RF-heads use, if hours are needed also for long distance RF heads RF Module RF Module RF Module System module Power Module RF Module RF Module RF Module AC in DC A C A C B System ModuIe B Power Module B B B B Locally sourced connection box P55 box needed if outdoors 7 Nokia Siemens Networks Presentation / Author / Date For internal use To System Module DC input Locally sourced DC cable connection and optional Fuses P55 box needed if outdoors FSEC can/may re-used if new type of inlets can be found. Anyway with four screw terminals this can be done FPAA FPAA FPBA 230 VAC 48 VDC 48 VDC 48 VDC + + - - FPMA #1 FPMA #2 FPMA #3 FPBA FPBA FPBAFPBAFPBA FPBA FPBAFPBAFPBA FIexi AC !ower ModuIe usage aIternative 5 when more battery back-up time is needed 8 Nokia Siemens Networks Presentation / Author / Date For internal use ong-term Integrated Battery Back-up Options FCSA FRMx 6000 + batteries (new) Requires aIways a cabinet I!20 rectifier => FCSA needed in Outdoor cabinet instaIIation MiBBU New rectifier moduIe fitting both cabinet and moduIe instaIIations 3 * 2000W With the I!54 rectifier variant, no need for extra I! protection Fast and easy instaIIation Nokia Siemens Networks Presentation / Author / Date For internal use FRMx FIexi Rectifier ModuIe 6000 (New) FRMx is going to be available in two different HW variants P20 based solution for indoor applications P55 based solution for outdoor applications x= B/C; code for OEM manufacture Supplier1/Supplier2 as in MBBU FRMx is meant to be a common solution for all Flexi 2G and 3G platforms Aim to replace current MBBU in Flexi applications FRMx will be equal to Flexi module in terms of dimensions and weight supporting Flexi platform modularity Same fixing points Same mounting options Wall, pole, stack FRMx brings some new possibilities for Flexi applications FRMx outside FCSA => more LTE space inside FCSA FRMx inside FCOA => more space for Flexi modules inside the cabinet 10 Nokia Siemens Networks Presentation / Author / Date For internal use FRMx TechnicaI Content FRMx have a scalable output power up to 6kW Max 3pcs of 2kW rectifiers AC connection either single or three phase Operating temperature range -35 to +55C Wide operating voltage range from 85 to 310VAC FRMx includes DC connection points for Max 2 BTS's Max 3 battery strings No space for batteries inside FRMx Battery banks reside in- or outside of the BTS cabinet or beside the stack 11 Nokia Siemens Networks Presentation / Author / Date For internal use Targeted FRMx AppIications FCSA Any 3 rd party 19" rack WaII/!oIe instaIIation with FIexi Stack instaIIation with FIexi FIexi OD cabinet (in/outside FCSA) FIexi ID or 3 rd party cabinet 12 Nokia Siemens Networks Presentation / Author / Date For internal use