Вы находитесь на странице: 1из 38

Internal

OWK100301 NodeB Troubleshooting


ISSUE 3.0
www.huawei.com

HUAWEI TECHNOLOGIES CO., LTD.

All rights reserved

References

RAN Troubleshooting Cases

SUPPORT.HUAWEI.COM

HUAWEI TECHNOLOGIES CO., LTD.

All rights reserved

Page 1

Upon completion of this course, you

will be able to:

Know how to find NodeB faults


Grasp NodeB troubleshooting methods Know how to prevent NodeB faults.

HUAWEI TECHNOLOGIES CO., LTD.

All rights reserved

Page 2

Chapter 1 General Introduction


Chapter 2 Typical Cases Chapter 3 NodeB Fault Prevention

HUAWEI TECHNOLOGIES CO., LTD.

All rights reserved

Page 3

General Introduction
The ways to find faults
Alarm

Alarm console Alarm box OMC Shell


Traffic statistics Drive test Routine inspection Customer complain

HUAWEI TECHNOLOGIES CO., LTD.

All rights reserved

Page 4

General Introduction
Locating faulty equipments

If RNC has fault, usually it will affect some Sites or all of Sites If NodeB has fault, usually it just affect itself and the handover

successful rate of adjacent cells


During implementation or expansion, we can Interchange

NodeB and judge the fault is because of RNC or NodeB


During maintenance, RNC faults dont just affect one NodeB

HUAWEI TECHNOLOGIES CO., LTD.

All rights reserved

Page 5

General Introduction
Common fault types
RAN fault Operation and maintenance

Cell Traffic Link Interconnection Clock Antenna & Feeder transmission

fault

OMC Software Loading


RNO fault

Access
Call drop Congestion

Handover

HUAWEI TECHNOLOGIES CO., LTD.

All rights reserved

Page 6

General Introduction
Basic troubleshooting methods
Analyzing the Alarm Information

Alarm information come from the RAN alarm system, indicated usually through sound, light, LED, and screen output, etc It includes the detailed description of the abnormality, possible causes and restoration suggestions, involves the hardware, link, trunk and CPU loading ratio, etc.. It is a gist for the fault analysis and location
Analyzing the Indicator Status

Indicators can indicate the work status of circuit, link, optical path, node and active/standby mode besides that of the corresponding boards, usually used along with the alarm information generally
HUAWEI TECHNOLOGIES CO., LTD.

Analyzing Traffic Statistics Result

All rights reserved

Page 7

General Introduction
Basic troubleshooting methods
Analyzing Apparatus & Meter Test Result

It reflects the fault nature with the visual and quantified data
Some common Apparatus & Meter Signaling Analyzer, Test phone, Sitemaster, etc.
Tracing the Interface

It is applied in locating the failure causes of subscriber call connection and inter-office signaling cooperation, etc. The trace result can help to find the cause of call failure directly and locate the problem or to get the index for the subsequent analysis
Traffic Test

It is a simple and quick method to judge whether the call processing function and relative modules of the RAN are normal or not
HUAWEI TECHNOLOGIES CO., LTD. All rights reserved Page 8

General Introduction
Basic troubleshooting methods
Comparison/Interchange

Comparison: compare the faulted components or phenomenon with the normal ones, and find the differences so as to find the problem

It is usually used in the situation with simple fault range


Interchange: if the fault can not be located even after the standby components are replaced, you can interchange the normal components (such as board, optical fiber, etc.) with the potential faulted components, and to compare the work status so as to specify the fault range or part It is usually used in the situation with complicated fault range
Switching/Resetting

It can not locate the fault cause accurately, and due to the randomness of software running, the fault may be not able to recur, thus it is difficult to know the real fault and solve the problem This method is just an emergency method, applicable only in the emergent situation Page 9 HUAWEI TECHNOLOGIES CO., LTD. All rights reserved

General Introduction
Basic troubleshooting methods
Contacting the Technical Support Engineers of Huawei Before you call, please collect information as follow

Detailed name of the office or site Linkman and telephone Time of fault occurring Software version of the office or site Detailed description of fault

Alarm files, interface tracing files, traffic statistic result


Actions performed after the faults occurring and the results Problem level and the time you wish to solve the problem

HUAWEI TECHNOLOGIES CO., LTD.

All rights reserved

Page 10

Summary
General Procedures of Troubleshooting

Finding fault>Judging Fault>locating fault>Removing Fault


Basic Methods of Fault Judgement and Location

For simple fault Analyzing the Alarm Information and the Indicator status

Comparison/Interchange
For complex fault Analyzing Traffic Statistics Result Analyzing Apparatus and Meter Test Result Tracing the Interface, Traffic Test For restoring system Switching/Resetting
HUAWEI TECHNOLOGIES CO., LTD. All rights reserved Page 11

Chapter 1 General Introduction


Chapter 2 Typical Cases Chapter 3 NodeB Fault Prevention

HUAWEI TECHNOLOGIES CO., LTD.

All rights reserved

Page 12

Chapter 2 Typical Cases 2.1 Transmission Faults 2.2 Operation and Maintenance Faults 2.3 Cell Faults

HUAWEI TECHNOLOGIES CO., LTD.

All rights reserved

Page 13

Transmission Faults
RAN Transport Network

HUAWEI TECHNOLOGIES CO., LTD.

All rights reserved

Page 14

Transmission Faults
Phenomena and Causes
Transmission Broken Transmission device, board or E1 is faulty More transmission device, more fault Transmission code is different (use CRC4 or not) High BER (bit error rate) Microwave, HDSL transmission, especially in rainy weather

E1 connection quality is bad


It will cause bad quality, even transmission broken The grounding system is faulty

HUAWEI TECHNOLOGIES CO., LTD.

All rights reserved

Page 15

Transmission Faults
Case1: E1 Broken (to be continued )
Description

E1 broken,E1 having alarm Troubleshooting methods This could be due to interface board faulty, E1 port faulty or E1 cable faulty 1. Check for alarm on the board and E1 port DSP BRD DSP E1T1 If board is faulty, then replace board 2. Board not faulty, but E1 port having alarm. Perform loop back test on local end SET E1T1LOP ( Loopback Type = LOCAL ) LOP E1T1RNC DSP E1T1NodeB SET E1T1LOP ( Loopback Type = NOLOOP) If E1 port is faulty, then replace board
HUAWEI TECHNOLOGIES CO., LTD. All rights reserved Page 16

Transmission Faults
Case1: E1 Broken (continued)

Troubleshooting methods

3. Board not faulty, E1 port not fault ,but alarm being in existence then perform loop back on far end and monitor at RNC SET E1T1LOP (Loop type=remote) Step 1: Check Board and ports Step 1: Check Board and ports >> DSP BRD DSP E1T1RNC >> DSP BRD >> DSP E1T1 >> DSP E1T1 If transport network is fault, then examine cable and device Step 2: Local Loop Back Step 2: Local Loop Back >> SET E1T1LOP (Loop type=local) >> SET E1T1LOP (Loop type=local) >> LOP E1T1 (Activate loop) >> DSP E1T1 >> SET E1T1LOP (Loop type=noloop)

Transport network

TX

RX TX

RNC

RX

NodeB

Step 3: Remote Loopback >> DSP E1T1


HUAWEI TECHNOLOGIES CO., LTD. All rights reserved

Step 3: Remote Loopback >> SET E1T1LOP (Loop type=remote)


Page 17

Chapter 2 Typical Cases 2.1 Transmission Faults 2.2 Operation and Maintenance Faults 2.3 Cell Faults

HUAWEI TECHNOLOGIES CO., LTD.

All rights reserved

Page 18

Operation and Maintenance System Faults


Fundamental Knowledge
NodeB provides two modes of operation and maintenance Near end operation and maintenance Far end operation and maintenance
NMPT Ethernet Port IP address IPoA Peer IP Subnet 4 RNC BAM IP IPoA local IP SNTP Server Subnet 1 Subnet 2 Subnet 3 Subnet 5

RNC M2000 BTS3812E LMT1 LMT 2

HUAWEI TECHNOLOGIES CO., LTD.

All rights reserved

Page 19

Operation and Maintenance System Faults


Case1: Downloading Software Package Lasts Too Long, Sometimes Software Downloading Fails

Description

In the course of software upgrading, it takes several hours to download the software package, and sometimes, the software downloading procedure fails

HUAWEI TECHNOLOGIES CO., LTD.

All rights reserved

Page 20

Operation and Maintenance System Faults


Case1: Downloading Software Package Lasts Too Long, Sometimes Software Downloading Fails
Troubleshooting methods

For maintenance over IPoA through RNC, check whether the IPoA bandwidth on RNC Operation and Maintenance system is too narrow Increase the IPoA bandwidth to speed up software downloading progress based on the actual situation.

HUAWEI TECHNOLOGIES CO., LTD.

All rights reserved

Page 21

Operation and Maintenance System Faults


Case2: Fail to Log in to NodeB by Near End Mode
Description

In near end maintenance mode, the Operation and Maintenance system can log in to NodeB normally before downloading data configuration file. When NodeB restarts after the data configuration file downloading procedure finishes, the Operation and Maintenance system cannot log in to NodeB by near end mode, but can log in to it over IPoA. In this case, board indicators are normal.

HUAWEI TECHNOLOGIES CO., LTD.

All rights reserved

Page 22

Operation and Maintenance System Faults


Case2: Fail to Log in to NodeB by Near End Mode
Troubleshooting methods

The reason for this fault may be incorrect setting of IP address of near end maintenance channel Step 1: Log in to NodeB over IPoA link through Operation and Maintenance system, configure IP for near end maintenance channel by using the MML command SET IP. Query whether the setting is successful by using the MML command LST IP.

Step 2: Open the data configuration file on the configuration management system to modify the NodeB property. Modify the local IP address as the value demanded, download the data configuration file again, and then restart the NodeB.

HUAWEI TECHNOLOGIES CO., LTD.

All rights reserved

Page 23

Chapter 2 Typical Cases 2.1 Transmission Faults 2.2 Operation and Maintenance Faults 2.3 Cell Faults

HUAWEI TECHNOLOGIES CO., LTD.

All rights reserved

Page 24

Cell Faults
Fundamental Knowledge
NodeB
NBAP_AUDIT_REQ NBAP_AUDIT_RSP NBAP_CELL_SETUP_REQ NBAP_CELL_SETUP_RSP NBAP_COMM_TRANSP_CH_SETUP_REQ NBAP_COMM_TRANSP_CH_SETUP_RSP NBAP_SYS_INFO_UPDATE_REQ NBAP_SYS_INFO_UPDATE_RSP

RNC

HUAWEI TECHNOLOGIES CO., LTD.

All rights reserved

Page 25

Cell Faults
Case1: No CELL SETUP REQUEST Message from RNC While NodeB in Normal State
Description

The logical cell cannot be setup. When you perform query with MML command on NodeB Operation and Maintenance system, the local cell resources are available, and both NCP and CCP states are normal. Upon receipt the request of resource audit from NodeB Operation and Maintenance system by MML command ADT RES, RNC delivers only a resource audit command but no CELL SETUP REQUEST message

HUAWEI TECHNOLOGIES CO., LTD.

All rights reserved

Page 26

Cell Faults
Case1: No CELL SETUP REQUEST Message from RNC While NodeB in Normal State
Troubleshooting methods

Check whether the maximum downlink power reported by NodeB in the audit message is smaller than the value configured by RNC. On NodeB Operation and Maintenance system, use the MML command DSP CELL to view whether the local cell ID is consistent with that specified in RNC

HUAWEI TECHNOLOGIES CO., LTD.

All rights reserved

Page 27

Cell Faults
Case2: Cell Deleted and Setup Repeatedly, RNC Multi-Frame Out-of-Synchronization Alarm Occurs, Cell Setup Fails
Description

From the message traced by Iub interface, cell is deleted and setup repeatedly. At the same time, there are multi-frame out-ofsynchronization alarms unable to be cleared in RNC. But E1 cable state is available when queried by the MML command DSP E1T1 on NodeB Operation and Maintenance system

HUAWEI TECHNOLOGIES CO., LTD.

All rights reserved

Page 28

Cell Faults
Case2: Cell Deleted and Setup Repeatedly, RNC Multi-Frame Out-of-Synchronization Alarm Occurs, Cell Setup Fails

Troubleshooting methods

The most possible cause for this fault is that E1 working mode for NodeB is not consistent with that for RNC: dualframe for NodeB, and multi-frame for RNC.

HUAWEI TECHNOLOGIES CO., LTD.

All rights reserved

Page 29

Cell Faults
Case3: Only One Cell Can Be Setup due to Modification of Cell Radius

Description

Originally, cell 0 and cell 2 can be setup normally. After the radius of both cell 0 and cell 2 is modified from 256*78 m to 1536*78 m, cell 2 is failed to setup. The local cell is unavailable due to lack of baseband resources according to the query result with the corresponding MML command.

HUAWEI TECHNOLOGIES CO., LTD.

All rights reserved

Page 30

Cell Faults
Case3: Only One Cell Can Be Setup due to Modification of Cell Radius
Troubleshooting methods

The fault must be caused by lack of access resources. A set of access resources includes an access ASIC and an access DSP. When the cell radius is smaller than or equal to 384*78 m, a set of access resources can support three cells. When the cell radius is greater than 384*78 m, it can support only one cell.

HUAWEI TECHNOLOGIES CO., LTD.

All rights reserved

Page 31

Cell Faults
Case4: RNC Deletes Cell after NodeB Responds with Cell and Common Transport Channel Setup
Description

RNC sends a CELL SETUP REQUEST message to NodeB, and NodeB reports a CELL SETUP RESPONSE message to RNC. Then RNC sends two COMMON TRANSPORT CHANNEL SETUP REQUEST messages. Upon receipt of the two COMMON TRANSPORT CHANNEL SETUP RESPONSE messages from NodeB, the RNC sends a CELL DELETION REQUEST message instead of a SYSTEM INFORMATION UPDATE REQUEST message. There is no alarm in NodeB or RNC

HUAWEI TECHNOLOGIES CO., LTD.

All rights reserved

Page 32

Cell Faults
Case4: RNC Deletes Cell after NodeB Responds with Cell and Common Transport Channel Setup

Troubleshooting methods

The fault may be relative to Iub interface user plane. In this case, it is necessary to check the user plane of NodeB and RNC in data configuration and hardware connection to see whether they are consistent.

HUAWEI TECHNOLOGIES CO., LTD.

All rights reserved

Page 33

Chapter 1 General Introduction


Chapter 2 Typical Cases Chapter 3 NodeB Fault Prevention

HUAWEI TECHNOLOGIES CO., LTD.

All rights reserved

Page 34

NodeB Fault Prevention

HUAWEI TECHNOLOGIES CO., LTD.

All rights reserved

Page 35

NodeB Fault Prevention


Hardware: installation specifications are most important

Pay more attention to E1 connector Pay more attention to feeder connector Pay more attention to the waterproofer of antenna and feeder system Confirm the grounding and lightning protection
Checking Running status

NodeB maintenance console First, do multi-site fault query, Then, try to remove the fault according to the alarm description and suggestion If you cannot remove the fault provisionally, confirm the Page 36 reason of every fault at least HUAWEI TECHNOLOGIES CO., LTD. All rights reserved

Thank You