Вы находитесь на странице: 1из 19

Paging in idle mode

Danny
2003/5/5
Agenda
Page behavior (UE)
Timing among PICH, P-CCPCH and SCCPCH
Receive parameters via SIB1 and SIB5
Paging Channel selection
Compute and get selected SCCPCH and PICH info.
Compute Paging Occasion
Get and Parse Page Indicator
Get Page message and Process

Value VIA Teamwork
Timing among PICH, P-CCPCH
and SCCPCH
Value VIA Teamwork

k:th S-CCPCH
AICH access
slots
Secondary
SCH
Primary
SCH
t
S-CCPCH,k
10 ms

t
PICH
#0 #1 #2 #3 #14 #13 #12 #11 #10 #9 #8 #7 #6 #5 #4
Radio frame with (SFN modulo 2) = 0 Radio frame with (SFN modulo 2) = 1



t
DPCH,n

P-CCPCH
Any CPICH
PICH for k:th
S-CCPCH
Any PDSCH
n:th DPCH
10 ms


Timing among PICH, P-CCPCH
and SCCPCH
The S-CCPCH timing may be different for different S-
CCPCHs, but the offset from the P-CCPCH frame timing
is a multiple of 256 chips, i.e. t
S-CCPCH,k
= T
k
256 chip,
T
k
e {0, 1, , 149}. [Extra ref 25.331 10.3.6.71]
The PICH timing is t
PICH
= 7680 chips prior to its
corresponding S-CCPCH frame timing, i.e. the timing of
the S-CCPCH carrying the PCH transport channel with the
corresponding paging information.
A paging indicator set in a PICH frame means that the
paging message is transmitted on the PCH in the S-
CCPCH frame starting t
PICH
chips after the transmitted
PICH frame.

Value VIA Teamwork
Page Channel Selection
After camping normally or camp on any cell, the
UE will select and monitor the indicated PICH
and PCH of the cell.
The UE get the indicated PICH and PCH
information via SIB5.

Value VIA Teamwork
Receive parameters via SIB1
and SIB5
SIB 1 procedure.
Get IEDRX cycle length coefficient
store the value of the IE "CN domain specific DRX
cycle length coefficient" for use in connected mode
SIB 5 procedure.
Select a S-CCPCH as specified in 25.304 and in
8.5.19, and start to receive PICH associated with the
PCH by the selected S-CCPCH using the parameters
given by the IE "PICH info"

Value VIA Teamwork
Index of selected SCCPCH (IDLE
mode)
The UE shall select a SCCPCH from the ones listed in
SIB 5 based on IMSI as follows:

"Index of selected SCCPCH" = IMSI mod K,

where K is equal to the number of listed SCCPCHs which
carry a PCH (i.e. SCCPCHs carrying FACH only shall not be
counted). These SCCPCHs shall be indexed in the order of their
occurrence in SIB 5 from 0 to K-1.


Value VIA Teamwork
Index of selected SCCPCH
(Connected mode)
When entering Connected mode from Idle mode by
sending an RRC CONNECTION REQUEST message, the
UE shall select the S-CCPCH which carries an FACH to
be used for reception of the RRC CONNECTION SETUP
message according to the following rule:

- the UE shall select an SCCPCH from the SCCPCHs listed in
System Information Block type 5 (SIB 5) based on "Initial UE
Identity" as follows:
"Index of selected SCCPCH" = "Initial UE Identity" mod K,

where K is equal to the number of listed SCCPCHs which carry a
FACH (i.e. SCCPCHs carrying PCH only shall not be counted ).
Value VIA Teamwork
Index of selected SCCPCH
If the UE has no IMSI, for instance when making an
emergency call without USIM, the UE shall use as
default number IMSI = 0.
Value VIA Teamwork
Compute Paging Occasion-
DRX
The UE may use Discontinuous Reception (DRX) in
idle mode in order to reduce power consumption.
When DRX is used the UE needs only to monitor one
Page Indicator, PI, in one Paging Occasion per DRX
cycle.
UE may attached to different CN domains. But UE
shall store all different DRX cycle length and uses
shortest of them.
The DRX cycle length shall be MAX(2
k
, PBP) frames,
where k is an integer and PBP is the Paging Block
Periodicity. PBP is only applicable for TDD and is equal to
the PICH repetition period that is broadcast in system
information. For FDD, PBP=1.

Value VIA Teamwork
Compute Paging Occasion
In FDD the UE shall monitor its paging indicator in
PICH frame with SFN given by the Paging Occasion.
The value of the Paging Occasion is determined as
follows:

Paging Occasion= {(IMSI div K) mod (DRX cycle length div
PBP)} * PBP + n * DRX cycle length + Frame Offset

Where n = 0,1,2 as long as SFN is below its maximum
value.
Value VIA Teamwork
Compute Paging Occasion
Value VIA Teamwork
.
.
.
1, k+1, 2k+1,...
2, k+2, 2k+2, ...
3, k+3, 2k+3, ...
k, 2k, 3k, ...
k
DRX Cycle
Compute Paging Occasion-PI
The actual Page Indicator within a Paging Occasion that
the UE shall read is similarly determined based on IMSI.
The page indicator to use is calculated by using
following formula:

PI = DRX Index mod Np
where DRX Index = IMSI div 8192
Np (for FDD, Np is the number of page indicators within a frame )

Ps. DRX Index = (IMSI div K) div (DRX cycle length div PBP)
Value VIA Teamwork

Get and Parse Page Indicator
-PICH format
Value VIA Teamwork
b
1
b
0
288 bits for paging indication
12 bits (transmission
off)
One radio frame (10 ms)
b
287
b
288
b
299
Number of paging indicators per frame
(Np)
Pq = 1 Pq = 0
Np=18 {b16q, , b16q+15} = {-1,-1,,-1} {b16q, , b16q+15} = {+1,+1,,+1}
Np=36 {b8q, , b8q+7} = {-1,-1,,-1} {b8q, , b8q+7} = {+1,+1,,+1}
Np=72 {b4q, , b4q+3} = {-1, -1,,-1} {b4q, , b4q+3} = {+1, +1,,+1}
Np=144 {b2q, b2q+1} = {-1,-1} {b2q, b2q+1} = {+1,+1}

Get and Parse Page Indicator
The PI calculated by higher layers for use for a certain UE,
is associated to the paging indicator P
q
, where q is
computed as a function of the PI computed by higher
layers, the SFN of the P-CCPCH radio frame during which
the start of the PICH radio frame occurs, and the number
of paging indicators per frame (Np):

Value VIA Teamwork

( ) ( ) ( ) Np
Np
SFN SFN SFN SFN PI q mod
144
144 mod 512 / 64 / 8 / 18
|
|
.
|

\
|
(

+ + + + =
Get and Parse Page Indicator
-Pq (DRX = 64)
Value VIA Teamwork
Get and Parse Page Indicator
-Pq (DRX = 128)
Value VIA Teamwork

Get Page message and Process

After receiving page message from SCCPCH, UE shall
If UE in idle mode, paging occasions are computed by IECN
domain specific DRX cycle length coefficient
If UE in CELL_PCH state or URA_PCH state, the paging
occasions are computed by IE UTRAN DRX cycle length
coefficient and IERRC State Indicator.
And process the Reception of a PAGING TYPE1 message by
UE procedure.
Value VIA Teamwork

Q & A
Value VIA Teamwork

Вам также может понравиться