VENT LINE ON DERRICK -

VENT LINE TO TOP OF DERRICK -

GALVANISED -
SIPHON BREAKER LINE
VENT
FLANGE -
INSP.PORT -
FLANGE -
OF PIPE-
OF PIPE-
MUD GAS SEPARATOR -
DISCHARGE -
FLANGE -
DRAIN- (VICTAULIC) ()
MANWAY - -
FLANGE -
DRAIN
MANIFOLD OUTLET
HALF COUPLING -
PLUG -
MANIFOLD CLEAN OUT
BLIND FLANGE -
MANIFOLD INLET-
API FLANGE-
SEE NOTE- .
CONC. RED. (TYP) - ()

CHOKE MANIFOLD -
BUFFER CHAMBER -
SWACO SUPER CHOKE- SWACO Super
ADJUSTABLE CHOKE -
HAMMER UNION -
OVERBOARD DISCHARGE LINE -
TOP OF DRILL FLOOR
ROTARY HOSE -
STAND PIPE MANIFOLD -
HAMMER UNION-
BLEED OFF LINE-
KILL LINE-
CHOKE LINE -
HIGH PRESSURE COFLEX HOSE TO BOP -
TO CEMENTING HEAD
TO STANDPIPE-
HP MUD LINE
FLEXIBLE HOSE -
DISCHARGE IN PIT
FRESH WATER -
DRILLING FLUID -
SEA WATER-
FUNNEL -
MAKEUP -
PREVENTOR ASSEMBLY -
MUD DITCH -

IN FLEXIBLE HOSE
HAMMER UNION FEMALE -
SOUR GAS SERVICE -
HAMMER UNION FULL SET -
CEMENTING UNIT-
CEMENT SUPPLY -
BOP STACK -
HAMMER UNION FULL -
POP OFF VALVE -
BLEED OFF LINE -
MUD PUMP-
TO MUD PIT-
TO LEG JETTING
IN DITCH DITCH
MAKEUP-
DISCHARGE PS -
DISCHARGE SB-

LEGEND-
BUTTERFLY VALVE -
FLEXIBLE HOSE-
STUDED TEE STUDED
PRESSURE RELIEF VALVE-
HYDRAULIC CONTROL VALVE-
CHECK VALVE-
LOW TORC PLUG VALVE - Lo-torc
GATE VALVE -

CONCENTRIC REDUCER-
PRESSURE GAUGE-
PRESSURE TRANSMITTER-
HAMMER UNION-
DVR -
DIVERTER-
WELL HEAD-
ANNULAR PREVENTER -
DOUBLE RAM PREVENTER -
SINGLE RAM PREVENTER -
TOP DRIVE VIREO - VIREO
BALL VALVE HYDRAULIC
BALL VALVE MANUAL-
DRILLING MUD (MANIFOLD) LINES ()
CHOKE MANIFOLD LINES
CEMENTING LINES-
Position of valves during normal drilling process
:
- in piping of BOP stack are open valves no 2 and 3. The rest of valves are closed.
- 2,3.

;
- in piping of drilling mud manifolds are open valves no 27,29,31,33,37,41 (or no
23,28,30,35,39,43). The rest of valves are closed.
- 27,29,31,33,37,41
( 23,28,30,35,39,43). ;
- in the piping of choke manifold are open valves no 8,16,17,20,21. The rest of
valves are closed.

- 8,16,17,20,21.
;
Position of valves at direct circulation killing:
:
- in piping of BOP stack are open valves no 2, 3, 4. The rest of valves are closed
- 2, 3, 4.
;
- in piping of drilling mud manifolds are open valves no 27,29,31,33,37,41 (or no
23,28,30,35,39,43). The rest of valves are closed.
- 27,29,31,33,37,41(
23,28,30,35,39,43). ;
- in the piping of choke manifold are open valves no 8,16,17,20,21, SSC 2. The rest
of valves are closed.
Position of valves at reverse circulation
:
- in piping of BOP stack are open valves no 1,2, 3. The rest of valves are closed
- 1,2, 3.
;
If using mud pumps:
:
- in piping of drilling mud manifolds are open valves no 35(or no 39, or no
43),23,25,28. The rest of valves are closed. To discharge install circulating head on
top of drilling string;
- 35 ( 39,
43) ,23,25,28. ;
;
- in the piping of choke manifold are open valves no 6,7,9,10,13. The rest of valves
are closed.
- 6,7,9,10,13.
;
If using cementing unit:

:
- in the piping of choke manifold are open valves no 5,6,13. The rest of valves are
closed.
- 5,6,13.
;
- in piping of drilling mud manifolds are open valves no 26,29,31 to discharge. The
rest of valves are closed.
- 26,29,31 .
;
Position of valves when using a diverter to discharge reservoir fluid:

:
- Open valves no 44 (or 46). The rest of valves are closed.
- 44 ( 46). ;
Characteristic of BOP stack:
:
Diverter:-
Annular preventer:
Ram preventer-
Rams pipe ram top, blind ram bottom ,

Annular preventer -
Double ram preventer -
Rams top, shear/blind ram bottom ,

Single ram preventer -
Ram pipe ram -
Choke and kill lines valves (on BOP)

hydraulic actuated
Diverter piping valves
hydraulic actuated-
Enumeration and characterization of the choke manifold valves:
:
Swaco super choke adjustable choke with hydraulic control - Swaco super
-
Adjustable choke - adjustable choke with manual control -
-
Enumeration and characterization of the drilling mud manifold valves:

Gate valve-
Plug valve-
Cementing unit manifold valves

Manual valve-
Butterfly valve (below main deck)- ( )