Eaton Hydraulic Screw-in Cartridge Valves (SiCV) E-VLSC-MC001-E6—February 2018 www.eaton.com C-3
ToughCoils™
Information
Where measurements are critical request certified drawings. We reserve the right to change specifications without notice.
C-4 Eaton Hydraulic Screw-in Cartridge Valves (SiCV) E-VLSC-MC001-E6—January 2018 www.eaton.com
ToughCoils
Model code S,P,J and H series coils
1 2 3 4 5 6 7 8
Thermal shock
Environmental protection Connector Ip65 Ip67 Ip69k dunk
Where measurements are critical request certified drawings. We reserve the right to change specifications without notice.
Eaton Hydraulic Screw-in Cartridge Valves (SiCV) E-VLSC-MC001-E6—January 2018 www.eaton.com C-5
ToughCoils
For 8 size solenoid valves
S & P series coils
12 DC 1.67
Voltage Type B
24 DC 0.83
36 DC 0.56
(+) (-)
24 AC 0.93
115 AC 0.19
230 AC 0.10
*Nominal voltage 25°C (77°F).
Where measurements are critical request certified drawings. We reserve the right to change specifications without notice.
C-6 Eaton Hydraulic Screw-in Cartridge Valves (SiCV) E-VLSC-MC001-E6—January 2018 www.eaton.com
ToughCoils
For 10, 12, 16 and 20 size solenoid valves
J & H series coils
G0** Q0 W0 N0 Y0 D0 J0
Voltage Connector Connector Connector Connector Connector Connector Connector
G0** Q0 W0 N0 Y0 D0 J0
Voltage Connector Connector Connector Connector Connector Connector Connector
Where measurements are critical request certified drawings. We reserve the right to change specifications without notice.
Eaton Hydraulic Screw-in Cartridge Valves (SiCV) E-VLSC-MC001-E6—January 2018 www.eaton.com C-7
S and P Series coils
Dimensions
28,0 [1.10]
Q0 W0
Spade connector Leadwire
N0 Y0
Deutsch Male DTO4-2P integrated connector AMP Junior timer integrated connector
29,7 33,9
[1.17] 24,1 [.95] [1.33] 25,4 [1.00]
D0 J0
Metri-Pack 150 Male, integrated connector Metri-Pack 280 Male, integrated connector
Where measurements are critical request certified drawings. We reserve the right to change specifications without notice.
C-8 Eaton Hydraulic Screw-in Cartridge Valves (SiCV) E-VLSC-MC001-E6—January 2018 www.eaton.com
J Series coils
Dimensions
33,5 [1.32]
(.685) 29,5 [1.16]
31,5 [1.24]
C
Ø 38,9 [1.53] 12,9 [.51]
46,5 [1.83]
G0
DIN 43650-A Connector Shown with integrated MetriPack 150 Connector
29,7 [1.17]
31,5 [1.24]
Q0 W0
Spade connector Leadwire
35,3 [1.39]
36,8 1.45] 5,1 [.20]
N0 Y0
Deutsch male DTO4-2P integrated connector AMP Junior timer integrated connector
33,3 37,3
[1.31] 27,7 [1.09] [1.47] 28,9 [1.14]
D0 J0
Metri-Pack 150 Male, integrated connector Metri-Pack 280 Male, integrated connector
Where measurements are critical request certified drawings. We reserve the right to change specifications without notice.
Eaton Hydraulic Screw-in Cartridge Valves (SiCV) E-VLSC-MC001-E6—January 2018 www.eaton.com C-9
H Series coils
Dimensions
33,5 [1.32]
(.685) 29,5 [1.16]
31,5 [1.24]
C 46,5 [1.83]
Ø 38,9 [1.53] 17,6 [.69]
G0
DIN 43650-A Connector Shown with integrated MetriPack 280 Connector
29,7 [1.17]
31,5 [1.24]
Q0 W0
Spade connector Leadwire
35,3 [1.39]
36,8 1.45] 5,1 [.20]
N0 Y0
Deutsch male DTO4-2P integrated connector AMP Junior timer integrated connector
33,3 37,3
[1.31] 27,7 [1.09] [1.47] 28,9 [1.14]
D0 J0
Metri-Pack 150 Male, integrated connector Metri-Pack 280 Male, integrated connector
Where measurements are critical request certified drawings. We reserve the right to change specifications without notice.
C-10 Eaton Hydraulic Screw-in Cartridge Valves (SiCV) E-VLSC-MC001-E6—January 2018 www.eaton.com
Large Tough Coils
Model Code L and R Series Coils
1 2 3 4 5 6 7 8 9 10
Thermal shock
Environmental protection Connector IP65 IP67 IP69K dunk
Caution
Coils may be hot
to touch if used in
continuous duty applications.
Where measurements are critical request certified drawings. We reserve the right to change specifications without notice.
Eaton Hydraulic Screw-in Cartridge Valves (SiCV) E-VLSC-MC001-E6—January 2018 www.eaton.com C-11
Large Tough Coils
L & R Series Coils
12VDC – – 041A – – –
24VDC – – 042A – – –
For other voltages and connectors contact your Eaton representative.
12 DC 2.35
Voltage Type B
C 24 DC 1.17
(+) (-)
*Nominal voltage 25°C (77°F).
Where measurements are critical request certified drawings. We reserve the right to change specifications without notice.
C-12 Eaton Hydraulic Screw-in Cartridge Valves (SiCV) E-VLSC-MC001-E6—January 2018 www.eaton.com
L Series Large Toughcoils
L Series Large Toughcoils
36.02
[1.418]
REF
Ø 46.28
[1.822]
MAX THIS END
C
Connector designed per deutsch
C
22.1
DT04-2P connector interface 34.11
[.870]
dwg. Rev. N/C [1.343]
REF
REF
43.76
33.60 [1.723]
[1.323] REF NOM
45.85-45.99
Ø
[1.805-1.811] 22.64-22.68
Ø [.891-.893]
17.65-17.71
Ø
[.695-.698]
N0
Deutsch Male DTO4-2P integrated connector
Where measurements are critical request certified drawings. We reserve the right to change specifications without notice.
Where measurements are critical request certified drawings. We reserve the right to change specifications without notice.
EATON Screw-In Cartridge Valves E1-VLSC-MC001-E3 February 2016 C-13.A
Eaton Hydraulic Screw-in Cartridge Valves (SiCV) E-VLSC-MC001-E6—January 2018 www.eaton.com C-13
RR Series LargeToughcoils
Series Large Toughcoils
Dimensions
Ø 46.28
Connector designed per [1.822]
Deutsch DT04-2P connector MAX THIS END 22.10
Interface DWG, rev. N/C [.870] REF
35.93
[1.414] REF
C 43.76
34.02 [1.723]
C 33.61 [1.323] REF
[1.339]
REF
NOM
45.85-46.00
Ø
[1.805-1.811]
23.64-23.71
Ø
[.931-.934]
51.49-52.00
[2.027-2.047]
Label may be located on either side of coil
N0
Deutsch Male DTO4-2P integrated connector
Where
Where measurements
measurementsare critical requestrequest
are critical certified drawings.
certified We reserve the
drawings. Weright to change
reserve the specifications
right to changewithout notice.
specifications without notice.
C-12.A
C-14 EATON Screw-In Cartridge Valves E1-VLSC-MC001-E3 February 2016
Eaton Hydraulic Screw-in Cartridge Valves (SiCV) E-VLSC-MC001-E6—January 2018 www.eaton.com
Legacy R & L Series Coils
For SVx-12-3 and SVx-12-4 solenoid valves
12V 30W
24V 30W
Where measurements are critical request certified drawings. We reserve the right to change specifications without notice.
Eaton Hydraulic Screw-in Cartridge Valves (SiCV) E-VLSC-MC001-E6—January 2018 www.eaton.com C-15
C13 and C16 Series -
coil information
Duty rating
The coil is rated for continuous operation at nominal voltage +/-
10% and an ambient range of -20 to +40.
FPO Electrical
Connection NNote: Coil performance, force produced and power consumed, is affected
by the heat of the coil, performance figures given in this catalogue
are measured under simulated continuous duty conditions at the coil
Bobbin stabilized temperature. It is important to verify the actual conditions the
valve will experience for any given application it should be tested in situ
Encapsulation to confirm valve selection.
-
AC Voltage Connector Circuit Diagram
Where measurements are critical request certified drawings. We reserve the right to change specifications without notice.
C-16 Eaton Hydraulic Screw-in Cartridge Valves (SiCV) E-VLSC-MC001-E6—January 2018 www.eaton.com
C13 and C16 Series -
solenoid coil
1 2 3 4
38.1
(1.50) 50.0
(1.97)
23.9 (0.94)
22.0
(0.87)
36.0
(1.42)
35.5
(1.40)
Where measurements are critical request certified drawings. We reserve the right to change specifications without notice.
Eaton Hydraulic Screw-in Cartridge Valves (SiCV) E-VLSC-MC001-E6—January 2018 www.eaton.com C-17
EPV Series proportional valve coils
EPV coils
12 DC 1.32 red 16 W
24 DC .66 black 16 W
*Nominal voltage @ 25°C (77°F).
F Q U* W Y
Coil part numbers Voltage Connector Connector Connector Connector Connector
Coil configurations “F”- Weather-Pack ”Q“ - Spade terminal ”U“– DIN 43650
male on leads
Caution
Coils may be hot to touch
if used in continuous duty
applications.
Where measurements are critical request certified drawings. We reserve the right to change specifications without notice.
C-18 Eaton Hydraulic Screw-in Cartridge Valves (SiCV) E-VLSC-MC001-E6—January 2018 www.eaton.com
EFV Series proportional valve coils EFV
M series coils
EHH-AMP-702
(Requires 24 VDC power supply to power plug and 12 VDC coil)
EHH-AMP-712
Power plug options (Requires 12 VDC power supply to power plug and 12 VDC coil)
EHH-PAM-600
DIN Rail Module (Requires 24 VDC power supply and 12VDC)
Specifications
Caution
Standard Voltage Resistance Power
C
Coils may be hot to touch
if used in continuous duty 12 VDC 4.7 Ω 30 W
applications. 24 VDC 19.0 Ω 30 W
1 2 3 4 5 6 7 8
53.3 MCSC012DGE00
54.6 6034440-001
(2.10) (2.15)
MCSC024DGE00 6034440-002
MCSC012DWE00 6034441-001
56,134 MCSC012DCE06 6034442-002
(2.21)
53.3 54.6
(2.10) (2.15)
Ø 44,2
(1.74)
Note: Width all
Ø 20,7 56,134
configurations
(0.815) (2.21)
Eaton Hydraulic Screw-in Cartridge Valves (SiCV) E-VLSC-MC001-E6—January 2018 www.eaton.com C-19
Electronic controls
Proportional valve
control power plugs
1 CAN Shield
2 Supply Positive
3 Supply GND
4 CAN H
5 CAN L
Model code
1 Adjustment range 2 Cable gland
1 2 K - Proportional plug:
4-20 mA with ramp
Operating data C
Electrical
Types D Type K
Connections
1 24V DC
2 Supply GND
3 Positive command signal
4 Negative command signal
18-36V DC including ± 10% maximum ripple
(peak-to-peak)
Power (input) supply 24V DC nominal
Absolute maximum voltage 40V
Max. power consumption including solenoid 35W
Reverse polarity protected Yes
Short circuit protected Yes
Maximum output current 1,6A
Maximum output voltage typical
(1,6A output current) Typically 1,5V below supply voltage
Command signal 0-10V (10 kohms) 4-20 mA (250 ohms)
Deadband triggering 200 mV 4 mA
For output (LED on) 200 mV to 10V 4-20 mA
For no output (LED off) 0 mV to 100 mV 0-4 mA
Deadband adjustment range 100 to 1000 mA
Gain adjustment range 0.02A/V to 0.16A/V 0.01 A/mA to 0.08 A/mA
Dither adjustment range 0 to 500 mA
Ramp time (types D and K only) 50 ms to 5s
PWM frequency 1200 Hz ± 10%
Dither frequency 120 Hz ± 10%
IEC 529: IP67 (when correctly installed with
interface seal in place) Fully short-circuit and
Protection reverse-polarity protected
Isolation to VDE 0110 Group “B”
Electromagnetic compatibility (EMC):
Emission EN 50081-2
Immunity EN 50082-2
Mechanical
Where measurements are critical request certified drawings. We reserve the right to change specifications without notice.
Eaton Hydraulic Screw-in Cartridge Valves (SiCV) E-VLSC-MC001-E6—January 2018 www.eaton.com C-21
Installation data
Input/output
characteristics
Type K and D Type J
Command signalType K and D Command Type J
signal
Type K TypeCommand
D signal voltage U s Command
signal
20 mA 10VType K Type D 10V voltage U s
8V 8V
12 mA 6V 20 mA 10V 6V 10V
4V 8V 4V 8V
2V 12 mA 6V 2V 6V
4 mA 4V Time 4V Time
C 4 mA
2V 2V
Output Ramp OutputTime Time
current setting current
Output Ramp Output
current setting current
USX USX
Gain setting USX Gain setting USX
Deadband Gain setting Deadband Gain setting
compensation compensation
Time
Deadband Time
Deadband
compensation compensation
Time Time
Installation dimensions
mm (inch)
88 (3.52) 3rd angle
22(3.52) projection
88 3rd angle
(0.87) projection
22
(0.87)
39 Solenoid Connections
(1.54)
39 Solenoid Connections
No connection
(1.54) 1 (or 2)
No connection
1 (or 2)
34
(1.34)
34
(1.34)
2
2 (or 1)
38
2
(1.5) 2 (or 1)
38
(1.5)
1
Where measurements are critical request certified drawings. We reserve the right to change specifications without notice.
C-22 Eaton Hydraulic Screw-in Cartridge Valves (SiCV) E-VLSC-MC001-E6—January 2018 www.eaton.com
3 – M12 5 pin connector • Available with CANOpen communications
Features and Benefits
• Integral amplifier provides essential functions for control Application
Installation data
of proportional valves. • Designed for the control of direct-operated, non-feed-
back, proportional valves where the cost of more com-
• Adjustable ramp time, gain, dead band compensation
plex electronic controls can be avoided.
through potentiometer or RS232/CAN communication (via
software).
Adjustments Terminal 1: Power Supply
• Ease of installation, with reduced cost. DC, positive.
18-36V
Ramp time: Turn clockwise
• to increase
Fully ramp time
short-circuit Terminal
and reverse-polarity 2: Power Supply 0V.
protected.
(Only types D/K).
• Terminal
Differential voltage command signal. 3: Command
Gain: Turn clockwise to signal positive
• increase with
Options (see ”Operating Data“).
gain. RS232 and CAN communication.
Deadband compensation: Terminal 4: Command
• Peak and Hold Functionality.
Turn clockwise to increase signal negative
• deadband
PG9, cable clamp and M12(see
M16 compensation ”Operating
connector Data“).
options.
current. C
• Adjustable
Dither: Turndither.
clockwise to
increase the dither current.
Wiring
Wiring
Set-up Diagrams
Diagrams
his product has been designed and tested to meet specific standards outlined in the European Electromagnetic Compatibility
Procedure
irective (EMC) 89/336/EEC, amended by 91/263/EEC, 92/31/EEC and 93/68/EEC, article 5. For instructions on installation
equirements to achieve effective protection levels, see this leaflet and the Installation Wiring Practices for Vickers Electronic
roductsThisleaflet 2468. Wiring
procedure describespractices relevanton
the adjustments tothe
this Directive
Power Plug areband.
indicated by Electromagnetic
Adjusting Compatibility
the power plug allows (EMC).
the dead-band to be
for setting the dead-band, gain and ramp rate on a non-feed- electronically eliminated (dead-band Compensation) by mak-
back proportional valve. Proportional valves with over-lapped ing the spool jump across the dead-band when a small input
spoolsInstallation wiring
have a range options
of spool travel where there is no flow signal is applied to the power plug.
from the valve. This range of spool motion is called dead-
The gain of the valve is the ratio of the opening of the valve • Ensure that sealing grommet is present and installed
(or flow rate from it) to the applied voltage input to the power correctly. It must be forced over the outer jacket of the
plug. The ramp rate is the rate at which the power plug allows cable.
the valve to open (or close) when a step voltage input is ap- • Ensure that all the gaskets are present and properly
plied to the power plug. In many applications this ramp would seated.
be used to gradually accelerate or decelerate an actuator.
• Ensure that the plastic cover seats firmly and correctly on
Installation precautions to eliminate leaks into the power the center body post.
plug:
• Use only cables with circular cross-sections and diameter
between 5–10 mm (.2” - .4”)
Warning
2 Electromagnetic Compatibility
EATON DPPP (EMC)
Catalog October - Screened
2011
cables should be used and particular attention paid
to the grounding of the screens as shown in the
above diagrams.
ConnectionWhere measurements
diagram are critical
for CAN version request certified drawings. We reserve the right to change specifications without notice.
(EHH-AMP-702-N-C-N-3-30)
Warning:
Warning: Electromagnetic
Electromagnetic Compatibility
(EMC)(EMC)
EatonCompatibility
Hydraulic Screw-in Cartridge Valves (SiCV) E-VLSC-MC001-E6—January 2018 www.eaton.com C-23
Screened cables should be used and particular
Screened cables should be used and particular attention
attention paid paid
to thetogrounding
the grounding
of theofscreens
the screens as shown
as shown in theinabove
the above diagrams.
diagrams.
Installation data
Assembly showing
wiring connection points
Warning
Ensure cable clamp nut is
adequately tightened to secure
cable. Do not connect, or
disconnect, the plug while
Assemblies
power is on. Do not mount,
or dismount, the plug while
power is on.
C
*All seals must be fitted correctly at plug installation to provide protection to IP67 (IEC 529).
Warning:
• Ensure cable clamp nut is adequately tightened to secure the cable.
• Do not connect, or disconnect, the plug while power is on.
• Doarenot
Where measurements mount,
critical or dismount,
request the plug
certified drawings. We while
reservepower
the rightistoon.
change specifications without notice.
C-24 Eaton Hydraulic Screw-in Cartridge Valves (SiCV) E-VLSC-MC001-E6—January 2018 www.eaton.com
Installation data
Where measurements are critical request certified drawings. We reserve the right to change specifications without notice.
Eaton Hydraulic Screw-in Cartridge Valves (SiCV) E-VLSC-MC001-E6—January 2018 www.eaton.com C-25
Electronic controls
“Soft Switch” power plugs
For use with valve types: hydraulic solenoid operated offer adjustable, ramped on/off
directional and pressure switching times through the Features and benefits
EPV**-12D-1* control valves where control of use of an integral amplifier. • Integral amplifier provides
EFV1-**-012DE* valve response time can The switching time range control from on/off logic
significantly reduce shocks in is 50 ms to 5 seconds. command signal
ERV1/2**-12D-1* the hydraulic system.
The soft switch plug is rated • Adjustable ramp time
EPRV1/3**-12D-1* Best results in reducing for 24V DC nominal and • Deadband compensation
ESV1**-12D-1* hydraulic shocks will only be controlled by a 24V logic
C IRV**-012D-1*
obtained by using valves with signal. Applying an “on” signal
• Adjustable output level
the right “low shock”, or “ • Adjustable dither
causes the output current to
PFR21* proportional” features. • EMC to latest European
ramp up to, and stay at, an
PFR24* adjustable maximum while the standards
PDR21A* “on” signal is maintained. At • Improved switching time
“switch-off” the output repeatability
PPD22**-012D-1* current is ramped down to • Fully short-circuit and
zero and will remain at zero reverse-polarity protected
until the next “on” signal.
• Protection to IP67
Ramp times (switching times)
can be adjusted by an
in-built potentiometer.
Where measurements are critical request certified drawings. We reserve the right to change specifications without notice.
C-26 Eaton Hydraulic Screw-in Cartridge Valves (SiCV) E-VLSC-MC001-E6—January 2018 www.eaton.com
Model code/
operating data
Model code
EHH - AMP - 702 - C - *
Operating data C
Electrical
Connections
1 24V DC
2 OV (power and signal)
3 Positive command signal
4 Negative command signal
18 - 36V DC including ± 10% maximum ripple
ripple (peak-to-peak)
Power (input) supply 24V DC nominal
Absolute maximum voltage 40V
Max. power consumption including solenoid 35W
Reverse polarity protected Yes
Short circuit protected Yes
Maximum output current 1,6A
Maximum output voltage typical
(1,6A output current) Typically 1,5V below supply voltage
Command signal
For output (LED on) 11 to 24V
For no output (LED off) 0V to 5V
Input impedance 10 KOhm ohms
Deadband adjustment range <100 - 1000 mA
Gain adjustment range 0.02A to 1,6A (maximum)
Dither adjustment range 0 to 500 mA
Ramp time 50 ms to 5s
PWM frequency 1200 Hz ± 10%
Dither frequency 120 Hz ± 10%
IEC 529: IP67 (when correctly installed
with interface seal in place)
Protection Fully short-circuit and reverse-polarity protected
Isolation to VDE 0110 Group “B”
Electromagnetic compatibility (EMC):
Emission EN 50081-2
Immunity EN 50082-2
Mechanical
Where measurements are critical request certified drawings. We reserve the right to change specifications without notice.
Eaton Hydraulic Screw-in Cartridge Valves (SiCV) E-VLSC-MC001-E6—January 2018 www.eaton.com C-27
Installation data
Deadband compensation
Time
Installation dimensions
mm (inch)
39 Solenoid Connections
(1.54)
No connection
1 (or 2)
34
(1.34)
2
2 (or 1)
38
(1.5)
1
Where measurements are critical request certified drawings. We reserve the right to change specifications without notice.
C-28 Eaton Hydraulic Screw-in Cartridge Valves (SiCV) E-VLSC-MC001-E6—January 2018 www.eaton.com
Installation data
e – Cable connection option • EMC to latest European standards.
1 – PG9 cable clamp
• Protection to IP67
2 – M16 cable clamp
3 – M12 5 pin connector • Terminal
Available with CANOpen communications
Adjustments Ramp time: Turn clockwise 1: Power Supply
Features and Benefits to increase ramp time. 18 - 36V DC, positive.
• Turn clockwise
Gain:functions
Integral amplifier provides essential to
for control Application
Terminal 2: Power Supply 0V.
of proportional valves. increase gain. • Terminal
Designed for thecommand
3: Switch control of direct-operated, non-feed-
Deadband compensation: back,
signal proportional valves where the cost of more com-
positive.
• Adjustable ramp time, gain, dead band
Turn compensation
clockwise to increase plex electronic
Terminal controls can be avoided.
4: Not connected
through potentiometer or RS232/CAN
deadbandcommunication
compensation (via
software). current.
• Ease of installation, with reduced cost. Turn clockwise to
Dither:
increase the dither current. C
• Fully short-circuit and reverse-polarity protected.
• Differential voltage command signal.
• Options with RS232 and CAN communication.
• Peak and Hold Functionality.
• PG9, M16 cable clamp and M12 connector options.
• Adjustable dither.
his product has been designed and tested to meet specific standards outlined in the European Electromagnetic Compatibility
Set-up Procedure
irective (EMC)Installation wiringamended by 91/263/EEC, 92/31/EEC and 93/68/EEC, article 5. For instructions on installation
89/336/EEC,
equirements to achieve effective protection levels, see this leaflet and the Installation Wiring Practices for Vickers Electronic
roductsThisleaflet 2468. Wiring
procedure practices
describes relevant
the adjustments tothe
on
24V this Directive
Power Plug areband.
indicated by Electromagnetic
Adjusting Compatibility
the power plug allows (EMC).
the dead-band to be
4 3 2 1
0V
for setting the dead-band, gain and ramp rate on a non-feed- electronically eliminated (dead-band Compensation) by mak-
back proportional >11 V
Warning valve. Proportional valves with over-lapped ing the spool jump across the dead-band when a small input
spoolsElectromagnetic
have a range Compatibility
of spool travel where there is no flow signal is applied to the power plug.
from (EMC) - Screened cables
the valve. This range of spool motion is called dead-Protective ground connection
should be used and particular
attention paid to the grounding
of the screens as shown in the
above diagram.
The gain of the valve is the ratio of the opening of the valve • Ensure that sealing grommet is present and installed
(or flow rate from it) to the applied voltage input to the power correctly. It must be forced over the outer jacket of the
plug. The ramp rate is the rate at which the power plug allows cable.
the valve to open (or close) when a step voltage input is ap- • Ensure that all the gaskets are present and properly
plied to the power plug. In many applications this ramp would seated.
be used to gradually accelerate or decelerate an actuator.
• Ensure that the plastic cover seats firmly and correctly on
Installation precautions to eliminate leaks into the power the center body post.
plug:
• Use only cables with circular cross-sections and diameter
between 5–10 mm (.2” - .4”)
Where measurements are critical request certified drawings. We reserve the right to change specifications without notice.
Eaton Hydraulic Screw-in Cartridge Valves (SiCV) E-VLSC-MC001-E6—January 2018 www.eaton.com C-29
Installation data
Assemblies
Assembly showing
wiring connection
points
Warning
Ensure cable clamp nut is
adequately tightened to secure
cable. Do not connect, or
disconnect, the plug while
power is on. Do not mount,
C or dismount, the plug while
power is on.
*All seals must be fitted correctly at plug installation to provide protection to IP67 (IEC 529).
Warning:
• Ensure cable clamp nut is adequately tightened to secure the cable.
• Do not connect, or disconnect, the plug while power is on.
• Do not mount, or dismount, the plug while power is on.
Where measurements are critical request certified drawings. We reserve the right to change specifications without notice.
C-30 Eaton Hydraulic Screw-in Cartridge Valves (SiCV) E-VLSC-MC001-E6—January 2018 www.eaton.com
Installation data
c. D
ecrease voltage: the LED An LED malfunction now
should go off when the indicates a short circuit at
voltage is less than 5V. the load.
• uccessful completion of
S
these checks means that
the plug and load are ready
for use.
Where measurements are critical request certified drawings. We reserve the right to change specifications without notice.