SELECTION GUIDE

InfiniiVision Oscilloscope
Probes and Accessories
For 1000 X-, 2000 X-, 3000A/T X-, 4000 X-, 6000 X-,
5000, 6000, and 7000 Series
Introduction
To achieve the best results from your scope, you need the right probes and accessories for your particular application. That is why
Keysight Technologies, Inc. offers a complete family of innovative probes and accessories for InfiniiVision oscilloscopes. For the most
up-to-date and complete information about Keysight’s accessories, please visit our Web site at: www.keysight.com/find/probes

Table of Contents
Introduction���������������������������������������������������������������������������������������������������������������������������������������������������2
Probe Compatibility Table�����������������������������������������������������������������������������������������������������������������������������3
Passive Probes�����������������������������������������������������������������������������������������������������������������������������������������������5
Extreme Temperature Passive Probe������������������������������������������������������������������������������������������������������������9
High-voltage Passive Probes���������������������������������������������������������������������������������������������������������������������� 10
InfiniiMax Active Probes and Accessories��������������������������������������������������������������������������������������������������� 11
InfiniiMode Active Probes and Accessories������������������������������������������������������������������������������������������������ 13
High-voltage Differential Active Probes – DP0001A High-Voltage Differential Probe����������������������������� 15
High-voltage Differential Active Probes����������������������������������������������������������������������������������������������������� 17
Single-ended Active Probes������������������������������������������������������������������������������������������������������������������������21
Mixed Signal Oscilloscope Logic Probes�����������������������������������������������������������������������������������������������������23
Clamp-on Current Probes���������������������������������������������������������������������������������������������������������������������������25
N7040A/41A/42A Rogowski Coil AC Current Probes���������������������������������������������������������������������������������29
High-sensitivity Current Probes������������������������������������������������������������������������������������������������������������������30
Wedge Probe Adapters�������������������������������������������������������������������������������������������������������������������������������32
Miscellaneous Accessories��������������������������������������������������������������������������������������������������������������������������33
T2A Probe Interface Adapter����������������������������������������������������������������������������������������������������������������������35
Recommended Probes for Low-/Mid-speed Bus Measurements��������������������������������������������������������������36

Find us at www.keysight.com Page 2


Probe Compatibility Table
For ordering information when replacing your probe or probe accessory: Refer directly to the page number listed in the Table of
Contents for your probe model.

To assist you in selecting the proper probe for your application: Use our probe compatibility table below to find the probes that
are recommended for use with your 1000 X-, 2000 X-, 3000A/T X-, 4000 X-, 6000 X-, 5000, 6000, and 7000 Series InfiniiVision
oscilloscope.

Probe type Probe model DSO 1000 X 1 MSO/DSO MSO/DSO MSO/DSO


2000 X 1 3000A/T X 4000 X/6000 X 2
Passive probes, N2142A 10:1/1:1 75 MHz (included in 1000 X 50 MHz models) Recommended
page 5 N2140A 10:1/1:1 200 MHz (included in 1000 X 70/100 MHz models) Recommended
N2862B/N2841A 10:1 150 MHz (included in 70/100 MHz models) Recommended Recommended Recommended Recommended
N2863B/N2842A 10:1 300 MHz (included in 200 MHz models) Recommended Recommended Recommended Recommended
N2890A/N2843A 10:1 500 MHz (included in 350/500 MHz/1 GHz Recommended Recommended Recommended Recommended
models)
N2840A 10:1 50 MHz Recommended Recommended Recommended Recommended
N2853A 10:1 350 MHz Recommended Recommended Recommended Recommended
N2894A 10:1 700 MHz (included in 4000 X/6000 X models) Recommended Compatible Compatible Recommended
N2889A 1:1/10:1 350 MHz Recommended Recommended Recommended Recommended
N7007A 10:1 400 MHz Recommended Recommended Recommended Recommended
High-voltage 10076C 100:1, 3.7 kV Recommended Recommended Recommended Recommended
passive probe,
page 10
Differential active 1130B to 1134B 1.5 to 7 GHz Incompatible Incompatible Recommended Recommended
probes, page 11 N2750A to N2752A 1.5 to 6 GHz Incompatible Incompatible Recommended Recommended
N2791A 25 MHz Recommended Recommended Recommended Recommended
N2891A 70 MHz Recommended Recommended Recommended Recommended
N2790A 100 MHz (with AutoProbe) Incompatible Incompatible Recommended Recommended
N2792A 200 MHz Incompatible Incompatible Recommended Recommended
N2818A 200 MHz (with AutoProbe) Incompatible Incompatible Recommended Recommended
DP0001A 400 MHz (with AutoProbe) Incompatible Incompatible Recommended Recommended
N2793A 800 MHz Incompatible Incompatible Recommended Recommended
N2819A 800 MHz (with AutoProbe) Incompatible Incompatible Recommended Recommended
N2804A 300 MHz Incompatible Incompatible Recommended Recommended
N2805A 200 MHz Incompatible Incompatible Recommended Recommended
Single-ended N2795A 1 GHz (with AutoProbe) Incompatible Incompatible Recommended Recommended
active probes, N2796A 2 GHz (with AutoProbe) Incompatible Incompatible Recommended Recommended
page 19
N2797A 1.5 GHz (with AutoProbe) Incompatible Incompatible Recommended Recommended
N7020A 2 GHz Incompatible Incompatible Recommended Recommended
MSO logic 01650-61607 16-channel Incompatible Incompatible Recommended Recommended
probes, page 21 N2755A 8-channel MSO cable (included in 2000 X-Series MSOs) Incompatible Recommended Incompatible Incompatible
N2756A 16-channel MSO cable (included in 3000, 4000, and 6000 Incompatible Incompatible Recommended Recommended
X-Series MSOs)
Current probes, 1146B 100 kHz Recommended Recommended Recommended Recommended
page 23 N2780B 2 MHz (use with N2779A) Compatible Recommended Recommended Recommended
N2781B 10 MHz (use with N2779A) Compatible Recommended Recommended Recommended
N2782B 50 MHz (use with N2779A) Compatible Recommended Recommended Recommended
N2783B 100 MHz (use with N2779A) Compatible Recommended Recommended Recommended
1147B 50 MHz (with AutoProbe) Incompatible Incompatible Recommended Recommended
N2893A 100 MHz (with AutoProbe) Incompatible Incompatible Recommended Recommended
N7026A 150 MHz (with AutoProbe) Incompatible Incompatible Recommended Recommended
N2820A 3 MHz/50 µA high sensitivity, 2 channel (with AutoProbe) Incompatible Incompatible Recommended Recommended
N2821A 3 MHz/50 µA high sensitivity, 1 channel (with AutoProbe) Incompatible Incompatible Recommended Recommended
N7040A/41A/42A Rogowski coil Recommended Recommended Recommended Recommended

1.  The 1000 X, 2000 X-Series does not support AutoProbe interface active probes.
2.  The 4000 X- and 6000 X-Series comes with the Infiniium AutoProbe interface for higher probe power support.

Find us at www.keysight.com Page 3


Probe Compatibility Table (Continued)
Probe type Probe model DSO5000A DSO5000A MSO/DSO6000A 4 MSO/DSO6000A 4
100 MHz 300 to 500 MHz 100 MHz 300 MHz to 1 GHz
MSO/DSO7000A/B
100 MHz to 1 GHz
Passive probes, N2863B 10:1 300 MHz (included in 5000 Recommended Recommended Recommended Compatible
page 5 Series 100/300 MHz)
10070D 1:1 20 MHz Recommended Recommended Recommended Recommended
10073D 10:1 500 MHz (included in Compatible Recommended Compatible Recommended
6000/7000 Series 300 MHz to 1 GHz and
5000 Series 500 MHz)
10074D 10:1 150 MHz (included in 6000 Recommended Compatible Recommended Compatible
Series 100 MHz)
N2873A 10: 1 500 MHz (optional to 7000B) Recommended Recommended Compatible Recommended

N7007A 10:1 400 MHz Recommended Recommended Recommended Recommended


High-voltage 10076C 100:1 3.7 kV Recommended Recommended Recomm ended Recommended
passive probe,
page 10
Differential active 1130B to 1134B 1.5 to 7 GHz 1 Compatible Recommended Incompatible Recommended
probes, page 11 N2750A 1.5 GHz Incompatible Incompatible Incompatible Incompatible
N2791A 25 MHz Recommended Recommended Recommended Recommended
N2891A 70 MHz Recommended Recommended Recommended Recommended
N2790A 100 MHz (with AutoProbe) Recommended Recommended Incompatible Recommended
N2792A 200 MHz Recommended Recommended Incompatible Recommended
N2818A 200 MHz (with AutoProbe) Incompatible Incompatible Incompatible Incompatible
DP0001A 400 MHz (with AutoProbe) Incompatible Incompatible Incompatible Incompatible
N2793A 800 MHz Recommended Recommended Incompatible Recommended
N2819A 800 MHz (with AutoProbe) Incompatible Incompatible Incompatible Incompatible
N2804A 300 MHz Incompatible Incompatible Incompatible Incompatible
N2805A 200 MHz Incompatible Incompatible Incompatible Incompatible
Single-ended active N2795A 1 GHz (with AutoProbe) Recommended Recommended Incompatible Recommended
probes, page 19 N2796A 2 GHz (with AutoProbe) Recommended Recommended Incompatible Recommended
N2797A 1.5 GHz (with AutoProbe) Incompatible Incompatible Incompatible Incompatible
N7020A 2 GHz Incompatible Incompatible Incompatible Incompatible
Mixed signal 01650-61607 16-channel Incompatible Incompatible Recommended Recommended
oscilloscope logic N6450-60001 2x8-channel
probes 2, page 21 (included in MSO6000A, MSO7000A/B)
Current probes, 1146B 100 kHz Recommended Recommended Recommended Recommended
page 23 N2780B 2 MHz (use with N2779A) Recommended Recommended Recommended Recommended
N2781B 10 MHz (use with N2779A) Recommended Recommended Recommended Recommended
N2782B 50 MHz (use with N2779A) Recommended Recommended Recommended Recommended
N2783B 100 MHz (use with N2779A) Recommended Recommended Recommended Recommended
1147B 50 MHz (with AutoProbe) Recommended Recommended Incompatible Recommended
N2893A 100 MHz (with AutoProbe) Recommended Recommended Incompatible Recommended
N7026A 150 MHz (with AutoProbe) Incompatible Incompatible Incompatible Incompatible
N2820A 3 MHz/50 µA high sensitivity, Incompatible Incompatible Incompatible Incompatible
2 channel (with AutoProbe)
N2821A 3 MHz/50 µA high sensitivity, Incompatible Incompatible Incompatible Incompatible
1 channel (with AutoProbe)
N7040A/41A/42A Rogowski coil Recommended Recommended Recommended Recommended

1.  The 1130B probe amplifier supports both single- and differential-ended measurements. Higher bandwidth InfiniiMax probe model 1131B, 1132B, and 1134B
are also supported by 3000 X-, 4000 X-, 6000 X-, 5000, 6000 300 MHz to 1 GHz models and, 7000 Series.
2.  Recommended for InfiniiVision MSOs only.
3.  These Infiniium active probes are not supported by InfiniiVision Series scopes – 1152A, 1153A, 1154A, 1155A, 1159A, 1168A/B, 1169A/B, N2800A, N2801A,
N2802A, N2803A, N2830A, N2831A, N2832A, N7000A, N7001A, N7002A, N7003A, and MX0023A.
4.  MSO/DSO6000A 100-MHz models do not support any Keysight active probes with AutoProbe interface.

Find us at www.keysight.com Page 4


Passive Probes
–  Designed for optimal performance with your Keysight InfiniiVision Series oscilloscopes
–  1:1 and 10:1 attenuation ratio
–  20 to 700 MHz

Rugged, high-quality probes at a reasonable price


Keysight 10070-family passive probes are a great choice if you are looking for high quality at
a very reasonable price. These general-purpose probes are designed specifically to give you
optimal performance with your InfiniiVision Series oscilloscopes. Ruggedized for general-
purpose measurements, they feature a durable cable and a solid stainless steel probe body
encased with a hard, fracture-resistant plastic. They are designed and tested to ensure the
probes operate in the toughest of conditions

The N28xxA/B low-cost, general-purpose passive probes provide up to 500 MHz bandwidth
and feature a high input resistance of 10 MΩ for low probe loading. These probes provide a
10:1 attenuation ratio except for the N2889A, which provides a switch in the probe handle for
switching the attenuation ratio between 1:1 and 10:1. The N284xA and N2853A are the new
version of passive probes with improved frequency response over N2862B/63B/90A probes.
These probes can be used in place of existing N2862B/63B/90A for better performance. The
N2853A is a 10:1 passive probe with 2 m cable length for extended cable connection.

The N2873A/N2894A are 500-MHz/700 MHz 10:1 miniature passive probes that can be used
with all InfiniiVision Series. Compact 2.5-mm probe head diameter, low input capacitance,
and various fine-pitch probe tip accessories make the N2873A/N2894A passive probes ideal
for probing densely populated IC components or surface-mount devices used in today’s
high-speed digital applications. The N2894A provides 700 MHz system bandwidth when used
in conjunction with the 4000 X- and 6000 X-Series ≥ 1 GHz models. For more information
about N2870A Series passive probes and accessories, refer to Keysight’s literature number,
5990-3930EN.

The N2140A 200 MHz and N2142A 75 MHz low-cost passive probes are high-impedance
probes with switchable attenuation ratio (1:1 and 10:1). These are compatible with the Keysight
InfiniiVision EDUX1002A/G and DSOX1102A/G oscilloscopes or similar oscilloscopes with
1 Mohm BNC input.

Find us at www.keysight.com Page 5


Passive Probes (Continued)
Accessories available for Accessories available for N2873A/N2894A (and other N287xA
10070D/73D/74D passive Series passive probes)
probes N4829A Probe tip kit (rigid and spring loaded), 10 each
N4848A Probe-tip-to-BNC (m) adapter, N4831A Sprung hook adapter 2.5 mm for N2870A/71A/ 72A/73A/75A, N2894A, qty 2
qty 2 N4837A Ground lead 15 cm, qty 2
5081-7696 Ground lead with 0960-2908 10 self-adhesive copper pads 2x2
alligator clip for 1007x and N4836A Dual lead-adapter, 2.5 mm, 10 cm, qty 2
N2862B/63B/89A/90A 0960-2977 Ground lead 11 cm to Miniclip
N4847A Retractable hook tip for 0960-2978 Ground lead 11 cm to 0.8 mm socket
1007xC/D (not compatible with 0960-2979 Rigid probe tips, qty 5
10076A/B), qty 2 N4838A Ground spring 2.5 mm, qty 2
N4849A Dual-test lead adapter (for 0960-2981 Spring-loaded probe tip, qty 5
10070/3/4x), qty 2 0960-2982 Ground blade 2.5 mm
5081-7690 Replacement parts accessory kit 0960-2983 IC cap 2.5 to 0.5 mm Green
10072A Fine-pitch probing kit includes 0960-2984 IC cap 2.5 to 0.65 mm Blue
10 SMT clips and 2 dual-lead 0960-2985 Insulating cap 2.5 mm
adapters 0960-2986 IC cap 2.5 to 1.27 mm Black
10075A 0.5 mm IC probing kit. 0960-2987 IC cap 2.5 to 1.27 mm Black
Contains 4 0.5 mm IC clips and 2 0960-2988 IC cap 2.5 to 0.8 mm Gray
dual-lead adapters 0960-2989 IC cap 2.5 to 1.0 mm Brown
0960-2990 Adapter 2.5 to 0.8 mm socket
N4863A 2.5 mm probe tip-to-PCB adapter, horizontal
N4864A 2.5 mm probe tip-to-PCB adapter, vertical
Accessories available for
N2140A/N2142A
N2141A Accessory kit for N2140A
Standard accessories that come with each probe
passive probe, 2 sets 10070D/10073C/10074C N2862B/63B/89A/90A and N2873A /N2894A
N2143A Accessory kit for N2142A N2840A/41A/42A/43A/53A
passive probe, 2 sets Retractable hook tip, qty 1 Retractable hook tip, qty 1 Spring loaded probe tips, qty 2
Colored identification tag, Colored identification tag, Rigid probe tips, qty 2
2 each of 4 colors 2 each of 4 colors
Ground bayonet, qty 1 Spring ground, qty 1 Ground blade, qty 1
Accessories available for IC insulation cap, qty 1 IC insulation cap, qty 1 Ground spring, qty 1
N2862B/63B/89A/90A and Adjustment tool, qty 1 Insulation cap, qty 1 Sprung hook, qty 1
Ground lead, qty 1 Adjustment tool, qty 1 (with Ground lead, qty 1
N2840A/41A/42A/43A/53A
N2862B/63B), qty 2 (with
passive probe N2889A/90A)
N2856A Accessory kit (containing all BNC adapter, qty 1 Ground lead, qty 1 Copper pads, qty 2
standard accessories) BNC adapter, qty 1 IC cap to 0.5 mm, 0.65 mm,
N2857A Alligator ground lead, qty 1 0.8 mm, 1 mm, 1.27 mm, qty
N2859A Replaceable probe tip 1 each
N2858A Retractable hook tip, qty 1 Probe tip, qty 1 BNC adapter, qty 1
N4827A PCB socket adapter, qty 2 Insulating cap, qty 1
N4826A Dual-lead adapter for, qty 2 Protection cap, qty 1
N4828A 5 mm ground spring for, qty 2 Trimmer tool, qty 1
1250-3978 BNC adapter Color coded rings, 3x4 colors

Find us at www.keysight.com Page 6


Passive Probes (Continued)
Ordering information for Keysight passive probes
N2142A 10:1/1:1 75 MHz passive probe
N2140A 10:1/1:1 200 MHz passive probe
10070D 1:1 20 MHz passive probe
N2840A 10:1 50 MHz passive probe
N2862B/N2841A 10:1 150 MHz passive probe
N2853A 10:1 350 MHz passive probe (2 m cable)
10074D 10:1 150 MHz passive probe
N2863B/N2842A 10:1 300 MHz passive probe
N2889A 10:1/1:1 350 MHz passive probe
10073D 10:1 500 MHz passive probe
N2890A/N2843A 10:1 500 MHz passive probe
N2873A 10:1 500 MHz miniature passive probe
N2894A 10:1 700 MHz miniature passive probe
N7007A 10:1 400 MHz extreme temperature passive probe (2 m cable)

10073D/74D passive probe N2873A/N2894A passive probe with standard N2140A/42A passive probe
accessories

N2862B/63B/90A passive probe N2889A 10:1/1:1 passive probe N2840A/41A/42A/43A/53A passive probe

Find us at www.keysight.com Page 7


Passive Probes (Continued)
Characteristics for Keysight passive probes
10070D 10073D 10074D
Bandwidth 20 MHz 500 MHz 150 MHz
Risetime (calculated) < 17.5 ns < 700 ps < 2.33 ns
Attenuation ratio 1:1 10:1 10:1
Input resistance 1 MΩ 2.2 MΩ 10 MΩ
Input capacitance Approx 70 pF Approx 12 pF Approx 15 pF
Maximum input (dc + peak ac) 300 Vpk mains isolated 500 Vpk mains isolated 500 Vpk mains isolated
150 Vpk CAT II 400 Vpk CAT II 400 Vpk CAT II
Compensation range None 6 to 15 pF 9 to 17 pF
Probe readout Yes Yes Yes
Cable length 1.5 m 1.5 m 1.5 m

N2862B,41A/ N2889A N2890A/N2843A N2873A/N2894A N2853A N2840A


N2863B,42A
Bandwidth 150 MHz/ 350 MHz (at 10:1), 500 MHz 500 /700 MHz 350 MHz 50 MHz
300 MHz 10 MHz (at 1:1)
Risetime (calculated) < 2.33 ns/ < 1 ns (at 10:1), < 700 ps < 700 ps/ < 1 ns < 7 ns
< 1.16 ns < 35 ns (at 1:1) < 500 ps
Attenuation ratio 10:1 1:1/10:1 switchable 10:1 10:1 10:1 10: 1
Input resistance 10 MΩ 10 MΩ (at 10:1) 10 MΩ 10 MΩ 10 MΩ 10 MΩ
1 MΩ (at 1:1)
Input capacitance Approx 11 pF Approx 11 pF (at 10:1), Approx 11 pF Approx 9.5 pF Approx 11 pF Approx 11 pF
60 pF (at 1:1)
Maximum input 300 V 300 V mains isolated/ 300 V 400 V mains 300 V 300 V
(dc + peak ac) mains isolated/ CAT II (at 10:1), 150 V mains isolated/ isolated2, mains isolated/ mains isolated/
CAT II mains isolated/CAT II CAT II 300 V CAT II CAT II CAT II
(at 1:1)
Compensation range 5 to 30 pF 5 to 30 pF (at 10:1) 5 to 30 pF 10 to 25 pF 5 to 30 pF 5 to 30 pF
Probe readout Yes No Yes Yes Yes No
Cable length 1.2 m 1.3 m 1.3 m 1.2 m 2m 1.2 m

1.  700 MHz BW only available on DSOX/MSOX 4000 X-Series oscilloscopes with 1 GHz or 1.5 GHz bandwidth models.
2.  300 Vrms, 400 V(dc + peak ac) mains isolated; 0 V transient overvoltage with InfiniiVision 6000X.

N2142A N2140A
Bandwiidth 75 MHz at 10:1 200 MHz at 10:1
6 MHz at 1:1 6 MHz at 1:1
Risetime (calculated) 4.66 nsec at 10:1 1.75 nsec at 10:1
58.3 nsec at 1:1 58.3 nsec at 1:1
Attenuation ratio 1:1/10:1 switchable 1:1/10:1 switchable
Input resistance 10 MΩ at 10:1 10 MΩ at 10:1
1 MΩ at 1:1 1 MΩ at 1:1
Input capacitance 15 pF at 10:1 15 pF at 10:1
100 pF at 1:1 100 pF at 1:1
Maximum input (dc + peak ac) 300 Vrms CAT II at 10:1 300 Vrms CAT II at 10:1
150 Vrms CAT II at 1:1 150 Vrms CAT II at 1:1
Compensation range 15 pF to 40 pF 15 pF to 40 pF
Probe readout No No
Cable length 120 cm 120 cm

Find us at www.keysight.com Page 8


Extreme Temperature Passive Probe
Features and specifications
–  Wide operating temperature range of –40 to +85 °C for extreme temperature
environmental chamber testing
–  400 MHz bandwidth (–3 dB)
–  High impedance (10 MΩ at DC) input
–  Wide input range: 1 kV CAT II, 600 V CAT III
–  Includes hook tip adapters (x2), ground leads (x2) and spring ground tip (x1)

The N7007A 400 MHz passive probe is a low-cost, high impedance passive probe with
rugged probe tips for environmental chamber testing from –40 to +85 °C. Its large
input impedance (10 MΩ at DC) and wide input voltage range (1,000 Vdc + peak AC
CATII) makes the probe ideal for a broad range of general purpose extreme temperature
applications.

N7007A Extreme temperature passive probe

Key characteristics
N7007A
Bandwidth 400 MHz (with spring ground), 70 MHz (with ground lead)
Attenuation ratio 10:1
Input impedance (at DC) 10 MΩ/15.5 pF (when terminated into 1 MΩ)
Oscilloscope compensation range 6 to 18 pF
Operating temperature range –40 to +85 °C
Operating humidity range < 90% at 40 °C
Cable length 2m
Max input range 1 kV CAT II, 600 V CAT III

Ordering information N7006A spring ground


N7007A 10:1 400 MHz extreme temperature passive probe
N7006A Spring ground for N7007A
N7008A Hook tip adapter for N7007A
N7009A Ground lead for N7007A

N7008A hook tip adapter

N7009A ground lead

Find us at www.keysight.com Page 9


High-voltage Passive Probes
–  Ideal for measuring up to 3.7 kV
–  Up to 500 MHz bandwidth
–  100:1 attenuation

10076C high-voltage probe


The Keysight 10076C 3.7 kV 100:1 passive probe gives you the voltage and bandwidth
you need for making high-voltage measurements. Its compact design makes it easier to
probe today’s small power electronics components and its rugged construction means it
can withstand rough handling without breaking.

10076C passive probe


Characteristics 10076C
Bandwidth 500 MHz (–3 dB)
Risetime (calculated) < 0.7 ns
Attenuation ratio 100:1
Input resistance 66.7 MΩ (when terminated into 1 MΩ)
Input capacitance Approx 3 pF
Maximum input 3700 Vpk, 2650 Vrms, 2650 Vdc (mains isolated)
1000 Vpk CAT II (post receptacle mains)
Compensation 6 to 18 pF range
Probe readout Yes
Cable length 1.8 m
Operating temperature 0 °C to 50 °C
N2789A spring ground clip for 10076B/C

Ordering information for Keysight high-voltage probes


10076C High-voltage probe: includes one retractable hook tip, one ground-bayonet, one IC
probing tip, one alligator ground lead, one spring ground tip and a compensation
screwdriver
10077A Accessory kit for 10076A/C: includes one retractable
pincher tip, one ground lead, one insulation cap, two measuring pins, and two
colored tags
N2789A Spring ground tip for 10076B/C 10077A accessory kit for 10076C

10076C derating curve

Find us at www.keysight.com Page 10


InfiniiMax Active Probes and Accessories
1130B-34B InfiniiMax Operating characteristics
high-performance active probe Probe bandwidth (–3 dB) 1134B: > 7 GHz
1132B: > 5 GHz
system
1131B: > 3.5 GHz
–  1.5 to 7 GHz InfiniiMax probe system 1130B: > 1.5 GHz
–  InfiniiMax probe amplifier supports Rise and fall time (10 to 90%) 1134B: 60 ps
both differential- and single-ended 1132B: 86 ps
measurements for a more cost- 1131B: 100 ps
effective solution 1130B: 233 ps
–  Unrivaled InfiniiMax probing Input capacitance Cm = 0.1 pF Cm is between tips
accessories support browsing, Cg = 0.34 pF Cg is ground for each tip
solder-in, and socketed use models at Cdiff = 0.27 pF differential mode capacitance = Cm + Cg/2
the maximum performance available Cse = 0.44 pF single-ended mode capacitance = Cm + Cg
–  Compatible with 3000 X/T-, Input resistance Differential mode resistance = 50 kΩ ± 2%
4000 X-, 6000 X-, 5000, 6000, and Single-ended mode resistance = 25 kΩ ± 2%
7000 Series oscilloscopes (except for Input dynamic range ± 2.5 V
6000 Series 100-MHz models) Input common mode range ± 6.75 Vdc to 100 Hz; ± 1.25 V > 100 Hz
Maximum signal slew rate 18 V/ns when probing a single-ended signal
The InfiniiMax 1130B Series probe 30 V/ns when probing a differential signal
amplifier is a perfect complement to the DC attenuation 10:1 ± 3% before calibration on oscilloscope
InfiniiVision 1 GHz or higher bandwidth 10:1 ± 1% after calibration on oscilloscope
models. Its bandwidth, extremely low Offset range ± 12.0 V when probing single-ended signal
input capacitance (0.32 pF), high common Maximum input voltage 30 Vpeak, mains isolated
mode rejection, and patented resistor ESD tolerance > 8 kV from 100 pF, 300 Ω HBM
probe tip technology provide ultra low Maximum number of probes 2
loading of the DUT and superior signal supported by 3000 X/T-/
fidelity. Keysight’s innovative InfiniiMax 5000/6000/7000 Series
1130B Series differential probe is the Maximum number of probes 4
easiest-to-use, highest performance supported by 4000 X- and 6000
probing system available for high-speed X-Series
digital design, and represents a new
industry standard for accuracy, flexibility,
and reliability. Designers can achieve full
system bandwidth in conjunction with
InfiniiVision Series oscilloscopes even
when manually browsing with the probe
or making hands-off measurements.

Optional solder-in probe heads and


solder-in sockets, as well as browser
configuration provide full bandwidth at
the probe tip.

Keysight 1130B InfiniiMax probe offers you the highest performance available for measuring
differential and single-ended signals

Find us at www.keysight.com Page 11


InfiniiMax Active Probes and Accessories (Continued)
1130B-34B InfiniiMax high-performance active probe system
Ordering information for Keysight InfiniiMax 1130B Series probe and accessories
Probe amplifier
1130B 1.5 GHz InfiniiMax probe amplifier (order one or more probe heads or connectivity kits per amplifier)
1131B 3.5 GHz InfiniiMax probe amplifier (order one or more probe heads or connectivity kits per amplifier)
1132B 5 GHz InfiniiMax probe amplifier (order one or more probe heads or connectivity kits per amplifier)
1134B 7 GHz InfiniiMax probe amplifier (order one or more probe heads or connectivity kits per amplifier)
Connectivity kits
E2669B InfiniiMax connectivity kit for differential/single-ended measurements
E2668B InfiniiMax connectivity kit for single-ended measurements
Individual probe heads
E2675B InfiniiMax differential browser probe head and accessories
E2676B InfiniiMax single-ended browser probe head and accessories
E2677B InfiniiMax differential solder-in probe head and accessories
E2678B InfiniiMax single-ended/differential socketed probe head and accessories
E2679B InfiniiMax single-ended socketed probe head and accessories
N2851A QuickTip probe head for InfiniiMax I/II probe amp
N2849A QuickTip tips for N2851A
N5380B InfiniiMax II differential SMA head
N5425B/N5426A 12-GHz differential ZIF solder-in probe head and ZIF probe tips
N5451A InfiniiMax long-wire ZIF probe tips (for use with N5425B ZIF probe head)
N5450B InfiniiMax extreme temperature extension cable (that allows for probing in environments from —55 to +150 °C)
N2880A InfiniiMax in-line attenuator kit (pairs of 6 dB, 12 dB and 20 dB attenuator in a kit)
N2881A InfiniiMax DC blocking caps (a pair of 30 Vdc blocking cap)

InfiniiMax solder-in probe head with long wires InfiniiMax ZIF tip soldered on board InfiniiMax browser head

For more comprehensive information about the 1130B InfiniiMax probe amplifier and its accessories, refer to the Keysight Infiniium
Osclloscope Probes, Accessories, and Options data sheet with Keysight literature number 5968-7141EN.

Find us at www.keysight.com Page 12


InfiniiMode Active Probes and Accessories
N2750A-52A InfiniiMode probe This, accompanied with superior signal Flexibility in probe use models is also a
fidelity, makes these probes useful vital necessity. The probes come standard
–  1.5 to 6 GHz bandwidth for most digital design and debug with three different types of exchangeable
–  Dual attenuation ratio (2:1/10:1) applications. And with their wide dynamic probe tips that allow for easy connections
–  InfiniiMode probing for making range (10 Vpp) and offset range (± 15 V), to the circuit under test. These probe tips
differential, single-ended and these probes can be used in a wide enable you to access multiple signals
common mode measurements with a variety of analog signal measurements as on anything from header connectors to
single probe well. hard-to-reach, high-density circuitry. The
–  Built-in quick action scope control probes are equipped with a white LED
for quick access to a variety of scope headlight to illuminate the circuit under
functions
InfiniiMode usability
test which will help you see where you are
–  Built-in headlight The N2750A comes with new InfiniiMode probing.
–  Includes solder-in, browser, and operation modes. The InfiniiMode allows
socketed tips standard convenient measurements of differential, This probe is compatible with InfiniiVision
–  AutoProbe interface for auto single-ended, and common mode 3000 X-Series with software ver. 2.2 or
configuration and probe power signals with a single probe tip without above, 4000 X-Series with software ver.
reconnecting the probe to change 3.01 or above, and 6000 X-Series with
the connection. The N2750A probe’s software ver. 6.00.
InfiniiMode provides the following modes
of operation.
Ordering information for
–  A – B (differential),
–  A – ground (single-ended A)
InfiniiMode probes and
–  B – ground (single-ended B) accessories
–  (A+B)/2 – ground (common mode) N2750A 1.5 GHz InfiniiMode differential
probe
Quick action scope control N2751A 3.5 GHz InfiniiMode differential
probe
The N2750A Series InfiniiMode probe N2752A 6 GHz InfiniiMode differential probe
provides convenient and quick access N2776A Differential browser tips (qty 3)
to various functions on the scope. You N2777A InfiniiMode solder-in tips (qty 3)
often have a need to control the scope N2778A InfiniiMode socketed tips (qty 3)
The N2750A Series InfiniiMode differential while you hold a probe in your hand. With N4822A Socketed tip for USB/Ethernet
probe is a new generation of low-cost, the quick action scope control feature application fixtures (qty 1)
differential active probe compatible with built into the probe, you can turn the
InfiniiVision 3000 X-, 4000 X-, 6000 built-in headlight of the probe on and off, Each probe includes two solder-in tips,
X-Series and Infiniium oscilloscope’s or control some frequently used scope two socketed tips and two browser tips.
AutoProbe interface. functions such as RUN/STOP, auto scale,
quick print, and quick save with only a
Measurement versatility button press on the probe. Get control of
your most needed function with a push
The N2750A Series InfiniiMode probe
of the quick action control button on the
offer 2:1 and 10:1 dual attenuation
probe.
settings, allowing them to be used for
a broad range of applications. Dual
attenuation range is automatically
configured depending on the size of the
input signal.

The new differential probe has an input


resistance of 200 kΩ (differential) or
100 kΩ (each input to ground), and an
extremely low input capacitance of 700 fF
to minimize circuit loading.

Find us at www.keysight.com Page 13


InfiniiMode Active Probes and Accessories (Continued)
Characteristics and specifications for N2750A Series InfiniiMode probes
Model number N2750A N2751A N2752A
Probe bandwidth 1 (–3 dB) 1.5 GHz 3.5 GHz 6 GHz
Rise time, probe only (10 to 90%) 233 ps 100 ps 58.3 ps
Input resistance (at DC) 1 200 kΩ ± 2% (differential mode)
100 kΩ ± 2% (single-ended mode)
50 kΩ ± 2% (common mode)
Input capacitance 700 fF (with browser)
Attenuation ratio (at DC) 2:1 / 10:1
Input dynamic range ± 1 V, 2 Vpp (at 2:1) / ± 5 V, 10 Vpp (at 10:1)
Input common mode range ± 15 V (from DC to 100 Hz), ± 2.5 V (for >100 Hz) 3
Offset range ± 15 V
Offset accuracy 2 < 3%
Maximum non-destructive input voltage ± 30 V (DC + peak AC)
Maximum number of probes supported by 3000 X-Series 1
Maximum number of probes supported by 4000 X-, 6000 4
X-Series

1.  Denotes warranted electrical specifications at 2:1 attenuation mode after 20 minute warm-up. All others are typical.
2.  When calibrated on the oscilloscope, these characteristics are determined by the oscilloscope characteristics.
3.  Assumes symmetric differential signals.

N2750A with browser tip N2750A with socketed tip N2750A with solder-in tip

For more information about the N2750A Series InfiniiMode probes, refer to the data sheet with the Keysight literature number,
5991-0560EN.

Find us at www.keysight.com Page 14


High-Voltage Differential Active Probes – DP0001A
High-Voltage Differential Probe
–  High voltage differential probe for high voltage, high speed power device testing
–  Measure up to 2 kV mains isolated, 1 kV CAT III and 400 MHz
–  Unmatched electrical performance - flat frequency response and high CMRR

The DP0001A is a 400 MHz high voltage differential probe with 2 kV mains isolated or 1 kV
CAT III rating designed for making accurate high-voltage power measurements required
for testing today’s WBG power devices, power converters or motor drives. Thanks to
high bandwidth and low loading characteristics, the probe can accurately measure 1 kV
transient pulse with as fast as 1.2 nsec of edge speed in modern switching power supplies.
Also, high CMRR simplifies the measurement challenges found in noisy, high common-
mode power electronics environments.

When used with an InfiniiVision oscilloscope, the probe provides four manually switchable
modes of attenuation to make low noise measurement at high V/div settings. The
differential probes have a differential input resistance of 10 MΩ and low input capacitance
of 2 pF to minimize circuit loading. The DP0001A is compatible with Keysight oscilloscopes
with a 50-Ω AutoProbe interface, which configures the scope for the probe automatically.

When probing differential signals inside of environmental chambers at extreme


temperatures, Keysight offers the N7013A extreme temperature extension kit. The N7013A
is compatible with the DP0001A with a de-rated bandwidth of 70 MHz. The 70 cm long
differential cable set and accessories can operate in temperatures ranging from -40 degC
to +85 degC.

The probe is compatible with InfiniiVision 3000TX, 4000X and 6000X models.

Frequency response of DP0001A

Find us at www.keysight.com Page 15


DP0001A characteristics and specifications
Value measured at the four supported attenuation modes
Characteristic
50:1 100:1 250:1 500:1
Probe bandwidth (-3 dB)
400 MHz 400 MHz 400 MHz 400 MHz
Risetime (10% - 90%)
Input voltage 50 V 1.2 nsec 1.2 nsec 875 psec 875 psec
Input voltage 500 V Not Applicable Not Applicable 1.2 nsec 1.2 nsec
Input voltage 1000 V Not Applicable Not Applicable Not Applicable 1.2 nsec
Maximum rated input voltage
2000 Vrms
Mains isolated *
6000 V Overvoltage Transient

CAT III
† 1000V

Noise (Vrms / spectral density) 180 mV / 9 μV/rt (Hz) 180 mV / 9 μV/rt (Hz) 280 mV / 14 μV/rt (Hz) 300 mV / 15 μV/rt (Hz)
(Referred to the input)
Typical propagation delay 10 ns
Maximum differential input voltage ± 200 V ± 400 V ± 1000 V ± 2000 V
(DC + AC peak)
Common mode voltage ± 2000 Vpk (1400 Vrms)
DC gain accuracy ± 0.7 % ± 0.7 % ± 0.35 % ± 0.35 %
Offset drift ** 150 μV / °C 150 μV / °C 40 μV / °C 40 μV / °C
Input impedance
Each input to ground 5 MΩ || 4pF
Differential Input Impedance 10 MΩ || 2pF
Input coupling of the oscilloscope
†† AutoProbe Interface 50 Ω
Typical CMRR (dB) DC > 80 > 80 > 80 > 80
100 kHz 75 70 65 60
1 MHz 75 70 65 60
10 MHz 70 58 54 32
100 MHz 45 40 35 32
Standard accessories Spring tips (qty 4), contact pins (qty 10), probe tip adapters (qty 2), safety alligator clips (qty 2),
alligator plunger clips (qty 2), spade terminals (qty 2), pincer clips (qty 2), hook tip adapters (qty 2),
coupler f-f (qty 1)
Max number of probes supported 1 (with 3000TX), 4 (with 4000X and 6000X)

* Mains isolated is for measurements performed on circuits not directly connected to a mains supply.
† Measurement category III is for measurements performed in the building installation.
‡ Broadband Noise, Bandwidth 400 MHz.
** Referred to the output of the probe.
†† Must be met to achieve the best performance and to avoid damage to the probe.
‡‡ DC gain and bandwidth are the only warranted specifications. All others are typical.

Ordering information
Model number Description
DP0001A 400 MHz high voltage differential probe
DP0002A Accessory kit for DP0001A
N7013A Extreme temperature probing kit for differential probe, probe BW derated to < 70 MHz with the
extension cable used

Find us at www.keysight.com Page 16


High-voltage Differential Active Probes
–  25 to 800 MHz bandwidth
–  High common mode rejection ratio
–  Measure up to 1,400 V CAT II and 7 kV mains isolated

N2790A/91A and N2891A high voltage differential probes


Oscilloscope users often need to make floating measurements where neither point
of the measurement is at earth ground. Use N2790A, N2791A, or N2891A high
voltage differential probes to make safe and accurate floating measurements with an
oscilloscope. The N2790A, N2791A, and N2891A high voltage differential probes allow
conventional earth-grounded Keysight oscilloscopes to be used for floating signal
measurements.

Each probe offers user-selectable attenuation settings that makes it highly versatile,
allowing it to be used for a broad range of applications. The probe comes with probe tip
accessories for use with small and large components in tight spaces.

The N2791A and N2891A are compatible with any oscilloscope with 1 MΩ BNC input.
The N2791A and N2891A probe power is supplied by included 4x AA batteries or USB
host port of the scope or PC via a supplied USB power cable. The N2790A is compatible
with the Keysight’s AutoProbe interface where the probe power is supplied by the
Keysight oscilloscope’s probe interface.

N2790A N2791A N2891A


Bandwidth 100 MHz 25 MHz 70 MHz
Risetime 3.5 ns 14 ns 5 ns
Attenuation ratio 50:1 / 500:1 10:1 / 100:1 100:1 / 1000:1
CMRR —80 dB at 50/60 Hz —80 dB at 50/60 Hz –80 dB at 50/60 Hz
—50 dB at 1 kHz —40 dB at 1 MHz –60 dB at 20 kHz
—50 dB at 1 MHz
Input impedance 8 MΩ / 3.5 pF 8 MΩ / 8 pF 100 MΩ / 5 pF
(between inputs)
Max input voltage to ± 1000 V (CAT II) ± 700 V at 100:1 ± 7000 V at 1000:1
ground ± 600 V (CAT III) ± 70 V at 10:1 ± 700 V at 100:1
Max input voltage ± 1400 V at 500:1 ± 700 V at 100:1 ± 7000 V at 1000:1
between two inputs ± 140 V at 50:1 ± 70 V at 10:1 ± 700 V at 100:1
Max number of probes 4 4 4
supported by 3000
X-/4000 X-/6000 X-/
5000/6000/7000 Series

Find us at www.keysight.com Page 17


High-voltage Differential Active Probes (Continued)
N7013A extreme temperature extension cable kit
The N7013A is a 70-cm long extreme temperature extension cable kit compatible with
four of Keysight’s medium- and high-voltage differential active probes, including the
DP0001A, N2790A, N2791A, N2792A, and N2818A. These probes are typically used
in power supply testing applications, as well as testing automotive differential buses
including CAN, CAN FD, and FlexRay. With the N7013A extension kit, the main body
of the temperature-sensitive differential active probe can be placed outside of the
environmental chamber, while the extension kit (70-cm long cable pair) and connection
adapters can be extended into the environmental chamber under extreme-temperature
conditions ranging from -40 to +85 °C.

The N7013A kit includes:


–  1 pair of extreme-temperature differential extension cables
N7013A Extreme Temperature Probing Kit
–  1 pair of extreme-temperature hook tip adapters
–  1 pair of extreme-temperature banana-to-socketed tip adapters for connecting to
0.025” square pins

The N7014A accessory includes: 1 pair of banana-to-socketed tip adapters

Key characteristics
Temperature range —40 to +85 °C
Cable length 70 cm
Derated bandwidth DP0001A, N2818A, N2792A, N2790A 70 MHz
Derated bandwidth with N2791A 25 MHz

N7014A Banana-to-socketed tip adapter

Find us at www.keysight.com Page 18


High-voltage Differential Active Probes (Continued)
N2804A/N2805A high-voltage, high-speed differential probes
The N2804A and N2805A differential probes provide the superior general-purpose
differential signal measurements that are required for high-speed power measurements
such as measuring characteristics of switching power devices, DC-DC converters or
class D amplifiers, vehicle bus measurements, and high-speed digital system designs.

The N2804A 300-MHz differential probe offers 100:1 attenuation ratio, allowing it to be
used adequately for high voltage signal measurements. The differential probe has a
differential input resistance of 4 MΩ and low input capacitance of 4 pF to minimize
circuit loading. The probe comes with a pair of extension leads (30 cm long) with a
damping resistor built-in to damp out the in-band resonance and provide flat frequency
response even while using the extension leads and probe tip accessories.

The N2805A is a 200-MHz differential probe designed to provide superior differential


signal measurements with a long cable length (5 m), making it ideal in an environment
where extended cable length is required. This probe comes with an extensive set of
probe tip accessories for use with small and large components in tight spaces.

Characteristics for N2804A and N2805A


N2804A N2805A
Bandwidth 300 MHz (without extension leads) 200 MHz N2804A 300 MHz differential probe
120 MHz (with extension leads)
Attenuation ratio 100:1 50:1
CMRR —80 dB at 50/60 Hz —75 dB at 50/60 Hz
—75 dB at 1 MHz —80 dB at 1 MHz
Input impedance 4 MΩ // 4 pF 4 MΩ // 4 pF
(between inputs)
Max input voltage ± 300 V (DC+ peak AC) and ± 200 V (DC+ peak AC) and
(between two inputs) ± 200 Vrms ± 200 Vrms CAT II
Max input voltage ± 300 V (DC+ peak AC) and ± 500 V (DC+ peak AC) and
± 200 Vrms CATII ± 500 Vrms mains isolated
± 1000 V (DC+ peak AC) and ± 300 V (DC+ peak AC) and
± 1000 Vrms CATI ± 200 Vrms CATII
Cable length 1.2 m 5m
Max number of probes 4 4
supported by InfiniiVision
Series
Compatible InfiniiVision 6000X Series, 4000X Series with software ver. 4.0 or higher, 3000X
oscilloscopes Series with software ver. 2.38 or higher

For more information about the N7020A power rail probe, refer to the Keysight data
sheet with the publication number 5992-0141EN.

N2805A 200 MHz differential probe

Find us at www.keysight.com Page 19


High-voltage Differential Active Probes (Continued)
N2792A/N2818A 200-MHz and N2793A/N2819A 800-MHz
general-purpose differential probe
The N2792A/N2818A 200-MHz and N2793A/N2819A 800-MHz differential probes
provide the superior general-purpose differential signal measurements required for
today’s high-speed power measurements, vehicle bus measurements, and digital system
designs.

The N2792A/N2818A and N2793A/N2819A probes offer a 10:1 attenuation setting, high
input resistance, and low input capacitance to minimize circuit loading.

The N2792A/93A are compatible with any oscilloscope with 50 Ω BNC input. The N2790A 100-MHz, 1.4-kV differential probe
with AutoProbe interface
probe can be powered by any USB port on a scope or computer, or by a 9 V battery.
The N2818A/19A are the AutoProbe interface versions of the N2792A/93A. They are
compatible with the InfiniiVision 3000 X-, 4000 X- and 6000 X-Series only.

Characteristics for N2792A/N2818A and N2793A/N2819A


differential probes
N2792A/N2818A N2793A/N2819A
Bandwidth 200 MHz 800 MHz
Risetime 1.75 ns 437 ps
Attenuation ratio 10:1 10:1
CMRR —80 dB at 50/60 Hz —60 dB at 50/60 Hz N2791A 25-MHz, 700-V differential probe
—50 dB at 10 MHz —15 dB at 500 MHz
Input impedance (between inputs) 1 MΩ // 3.5 pF 200 kΩ // 1 pF
Max input voltage to ground ± 60 V ± 40 V
Max input voltage between two inputs ± 20 V ± 15 V
Max number of probes supported by 4 4
InfiniiVision Series

Ordering information for Keysight high voltage differential probes,


power supplies and accessories
N2790A 100-MHz, 1.4 kV differential probe with AutoProbe interface
N2791A 25-MHz, 700-V differential probe
N2792A 200-MHz, 20-V differential probe
N2818A 200-MHz, 20-V differential probe with AutoProbe interface N2792A 200-MHz, 20-V differential probe
DP0001A 400-MHz, 2,000 V differential probe with AutoProbe interface
N2793A 800-MHz, 15-V differential probe
N2819A 800-MHz, 15-V differential probe with AutoProbe interface
N2891A 70-MHz, 7,000-V differential probe
N4853A Variable pitch browser for N2793A/N2819A, qty 2
N4854A DC blocking capacitor for N2793A/N2819A, qty 2
N2804A 300 MHz high voltage differential probe
N2805A 200 MHz high voltage differential probe with extended cable length
N2816A Probe tip accessory kit for N2804A including 2 alligator clips, 2 pincer clips, and
2 extension leads (30 cm)
N2817A Probe tip accessory kit for N2805A including 2 alligator clips, 2 hook clips, 2 pincer
clips, and 2 browser tips N2793A 800-MHz, 15-V differential probe
DP0002A Probe tip accessory kit for DP0001A
N7013A Extreme temperature extension cable kit for N2790A, N2791A, N2792A, and N2818A

Find us at www.keysight.com Page 20


Single-ended Active Probes
N2795A/96A/97A low-cost The N2795A/96A/97A are equipped
with a white LED headlight to illuminate
single-ended active voltage
the circuit under test. The probes are
powered directly by the InfiniiVision and
Infiniium Autoprobe interface, eliminating
the need for an additional power supply.
The probes also come with a number
of accessories that allow for easy
connections to the circuit under test.

Model number N2795A N2796A N2797A


Probe bandwidth 1 (–3 dB) 1 GHz 2 GHz 1.5 GHz
–  High resistance (1 MΩ) and low Risetime 350 ps 175 ps 233 psec
capacitance (1 pF) input for low System bandwidth 500/600 MHz with 1 GHz with Keysight’s 1 GHz
loading Keysight’s 500/600 InfiniiVision/Infiniium, 1.5 GHz with
–  Wide input dynamic range (± 8 V) and MHz InfiniiVision/ Keysight’s 1.5 GHz InfiniiVision
offset range (± 12 V for N2796A/97A, Infiniium, 1 GHz with 1 GHz 4000 X, 6000 X
InfiniiVision 3000 X, 4000 X
± 8 V for N2795A)
Attenuation ratio (at dc) 10:1 ± 0.5%
–  Built-in headlight Input dynamic range –8 to +8 V (DC or peak AC)
–  Direct connection to AutoProbe Non-destructive input voltage –20 to +20 V
interface (no power supply required) Offset range ±8V ± 12 V
–  N2797A for extreme temperature DC offset error (output zero) ± 1 mV
environmental chamber testing at Low frequency accuracy 0.5% at 70 Hz, 1 Vpp
–40 to +85 °C Input resistance 1 1 MΩ
Input capacitance 1 pF
The N2795A/96A are a new generation of Output impedance 50 Ω
low-cost, 1 to 2 GHz single-ended active Max number of probes 2
probes with the AutoProbe interface supported by InfiniiVision 3000
X-/5000/6000/7000 Series 2
(compatible with Keysight’s InfiniiVision
Max number of probes 4
and Infiniium family of oscilloscopes). supported by InfiniiVision
These probes integrate many of the 4000X, 6000X
characteristics needed for today’s general- 1.  Denotes warranted electrical specifications after 20 minute warm-up, all others are typical.
purpose, high-speed probing–especially in 2.  The N2797A is compatible with 3000 X/T-, 4000 X- and 6000 X-Series only.
digital system design, component design/
characterization, and educational research
Replacement accessories
applications. Its 1 MΩ input resistance N4839A Dual lead socketed adapter, 6 cm, qty 2
and extremely low input capacitance (1 N4840A Dual lead solder-in adapter, 5 cm, qty 2
pF) provide ultra low loading of the DUT. N4841A Dual lead socketed adapter, 9 cm, qty 2
This, accompanied with superior signal N4842A Dual pin PCB header, qty 2
fidelity, makes these probes useful for N4843A Solderable tips, qty 10
most of today’s digital logic voltages. N4844A Right angle ground lead, 5 cm, qty 2
N4845A Ground blade, qty 2
Testing devices over extreme temperature
N4846A Offset ground, qty 2
ranges is quite common these days. The
N2797A 1.5 GHz single-ended active probe
is the industry’s first low-cost high input
impedance active probe with rugged probe
tips for environmental chamber testing
of ICs and devices. It gives the ability
to probe signals at drastic temperature
swings ranging from –40 to +85 °C. The
probe provides a 2 m long cable. Order
N2798A for re-ordering accessories. For more information about N2795A/96A/97A active probe, refer to the Keysight
N2795A/96A/97A active probe data sheet, literature number 5990-6480EN

Find us at www.keysight.com Page 21


Single-ended Active Probes (Continued)
N7020A power rail probe
–  2-GHz single-ended active probe for power rail noise measurement
–  1.1:1 attenuation ratio ensures low noise signal measurement
–  ± 24 V of probe offset range enables effective elimination of DC component of a
power supply.

The N7020A power rail probe is a low noise, large offset range oscilloscope probe that
enables users to measure small signals riding on top of DC power rails.

–  Low noise: The N7020A power rail probe is a 1:1 attenuation ratio active probe. As
a general rule, the higher a probes attenuation ratio, the nosier the signal will be on
the oscilloscope.
–  Large offset range: The N7020A power rail probe provides ± 24 V of probe offset.
This enables users to center the signal on screen while placing the oscilloscope at
its maximum vertical sensitivity and zoom in on the signal.
–  Low DC loading: The N7020A power rail probe has 50 kΩ input impedance at DC,
minimizing the probe’s DC loading of the power rail.
–  Large input dynamic range: The N7020A power rail probe’s ± 850 mV input dynamic N7020A power rail probe
range means that users can measure up to ± 850 mV deviations of their DC
supplies. This is very useful for measuring programmable supplies like those used in
microcontroller power saving modes.
–  Supporting three connection options — pigtail solder head (2 GHz), SMA (2 GHz),
and browser (350 MHz).

Characteristics and specifications


Probe bandwidth (—3 dB) 2 GHz
Attenuation ratio 1.1:1
Offset range ± 24 V
Input impedance at DC 50 kΩ
at > 1 MHz 50 Ω N7023A browser kit (now included in the
N7020A or orderable separately)
Input dynamic range ± 850 mV
Probe noise 10% of oscilloscope noise
Included accessories N7021A coaxial probe head (qty. 3), N7022A SMA main cable,
N7023A browser kit
Max number of probes supported 4
by InfiniiVision
Compatible InfiniiVision 3000X/T-Series with software ver. 2.38 or higher
oscilloscopes 4000 X-Series with software rev. 4.0 or higher
6000 X-Series with software rev. 6.10 or higher

For more information about the N7020A power rail probe, refer to the Keysight data
sheet with the publication number 5992-0141EN.

Find us at www.keysight.com Page 22


Mixed Signal Oscilloscope Logic Probes
–  Compatible with all 40-pin logic Characteristics for Keysight Ordering information for
probes
54620-68701, N6450-60001, Keysight logic probes
–  Flying leads offer flexibility and
convenience N6459-60001 logic probes N2756A 16 ch 4 x 4 MSO cable kit
Input impedance 100 kΩ for 3000, 4000, and 6000
X Series MSO. Includes
MSO probes offer great value Input capacitance 8 pF
18 grabbers, 5 right
and performance angle grounds, and 5 ground
The 01650-61607 is the 40-pin (F) to
These logic probes for the InfiniiVision extension leads
40-pin (F) logic probe cable for Keysight’s
mixed signal oscilloscopes (MSOs) N2755A 8 ch 2 x 4 MSO cable kit
InfiniiVision and 54600 Series MSOs.
are the same ones used with Keysight for 2000 X Series MSO.
This cable gives the MSO the standard
industry- leading high-performance Includes 9 grabbers, 3 right
40-pin female input connector that many
logic analyzers. This means we can offer angle grounds, and 3 ground
Keysight logic analyzers have. With this
the best performance, great value, and extension leads
cable, a user can connect a wide variety
access to the industry’s broadest range of 01650-61607 40-pin (F) to 40-pin (F) logic
of logic analyzer probes such as Mictor,
logic probing accessories. probe cable
Samtec, and Soft Touch probes. Please
note that the 01650-61607 logic probe
The N2756A 4 x 4 signal logic probes are
cable is no longer available for purchase.
divided into four sets of four channels
Without the 01650-61607, 40-pin to
so you can probe pins that are far apart
40-pin cable, 40-pin Mictor, Samtec or
and work conveniently with only one set
Soft Touch probes you may already own
if that’s all you require. For optimal signal
cannot be used with InfiniiVision MSOs.
fidelity, connect ground at each logic
probe, in addition to taking a common
ground to all four signals via a separate Characteristics for Keysight
ground connector on the probe pod. The 01650-61607 logic probe
N2756A probe is included with 3000, Input impedance 100 kΩ
4000, and 6000 X-Series MSOs. Input capacitance 12 pF

The N2755A is an 8-channel MSO logic


probe designed to work with the 2000
X-Series MSOs. N2756A 16-ch MSO cable kit

01650-61607 logic probe

N2755A 8-ch MSO cable kit

Find us at www.keysight.com Page 23


Mixed Signal Oscilloscope Logic Probes (Continued)
The InfiniiVision MSO digital channels were designed to be compatible with a wide
variety of probing accessories developed over 20 years for logic analyzers. There is a
good chance that the logic analyzer accessories you already own work with your MSO.
With the addition of an optional 40-pin cable, 01650-61607, the MSO accepts numerous
logic analyzer accessories:

–  E5346A 34-channel Mictor connector probe


–  E5385A 34-channel Samtec connector
–  E5383A 16-channel flying lead set
–  01650-63203 16-channel termination adaptor (also available as a bundle of both
the termination adapter and the 40-pin cable with PN 10085-68701)
–  E5404A 34-channel soft touch pro connectorless probe
–  E5394A 34-channel soft touch connectorless probe
–  E5396A 16-channel soft touch connectorless probe
–  Any other accessory that connects to a logic analyzer via a 40-pin cable

For logic accessories of greater channel width than MSO digital channels
(> 16 channels), there are two use models.

E5396A 16-channel soft touch connectorless


–  Route up to 16 signals to the probe and do not use the additional probe channels.
probe
–  Route up to 32 signals to the probe and measure half of them at a time. Simply plug
the 40-pin cable to the other side of the probe to see the other half of the signals.

E5346A 34-channel Mictor connector probe E5385A 34-channel Samtec connector probe

Find us at www.keysight.com Page 24


Clamp-on Current Probes
–  Up to 150 MHz bandwidth and 1147B/N2893A/N7026A N2780B/81B/82B/83B/83L
500 Arms current measurement range
50-MHz/100-MHz/150-MHz 2‑MHz/10-MHz/50-MHz/100-
–  Hybrid technology to measure ac and
dc current probe with AutoProbe MHz current probes
–  Compatible with 1 MΩ scope input interface The N2780B Series current probes are
The 1147B/N2893A/N7026A have high bandwidth, active current probes,
Accurate current measurements wide bandwidth ranges, from DC to featuring flat bandwidth, low noise
without breaking the circuit 50-MHz/100-MHz/150-MHz. The probes (2.5 mArms) and low circuit insertion
offer flat frequency response across the loss. In conjunction with the power supply
Compatible with any scope or voltage
entire bandwidth range, low noise (2.5 (model N2779A), these probes can be
measuring instruments with BNC input, the
mArms for 1147B/N2893A, 250 µArms for used with any oscilloscope having a high-
1146B and N2780B Series current probes
N7026A) and low circuit insertion loss. impedance BNC input. The companion
offer accurate and reliable solutions
power supply N2779A (3 x 12 Vdc output)
for measuring dc and ac currents. The
These three current probes are lets you connect up to any three N2780B-
probes use a hybrid technology that
compatible with the AutoProbe interface, 83B current probes to a single power
includes a Hall effect sensor that senses
which completely configures the supply.
the dc current, and a current transformer
oscilloscope for the probe. AutoProbe can
that senses the ac current, making
be found on the InfiniiVision 3000T X-, The N2783L 80 MHz current probe
it unnecessary to make an electrical
4000 X-, and 6000 X-Series. Probe power offers a 5-m long cable, which allows
connection to the circuit.
is provided by the scope. The N2893A you to reach DUTs over long distances
and N7026A uniquely provide auto very easily. Other than the bandwidth
1146B 100 kHz current probe demagnetization and offset elimination performance, the N2783A and N2783L
The 1146B ac/dc current probe provides feature when used in conjunction with have the same electrical performance.
accurate display and measurement of InfiniiVision or Infiniium oscilloscopes. The N2783L also requires the N2779A
currents from 100 mA to 100 Arms, dc to power supply to power the probe. The
100 kHz, without breaking into the circuit. N2779A is UL listed.
A battery level indicator and overload
indicator help ensure proper readings. It
connects directly to the scope through a
2-m coaxial cable with an insulated BNC.

1147B 50-MHz current probe with AutoProbe N2893A 100-MHz current probe with N7026A 150-MHz high sensitivity current
interface AutoProbe interface probe with AutoProbe interface

1146B 100-kHz current probe N2780B Series current probes with N2779A
power supply

Find us at www.keysight.com Page 25


Clamp-on Current Probes (Continued)
N7026A high sensitivity clamp-
on current probe
1 mA/div sensitivity
The N7026A is the Keysight’s highest
sensitivity clamp-on current probe. It
has up to 5x lower noise than our other
clamp-on current probes with 0.1V/A
output voltage rate. This enables you to
measure down to 1 mA/div with much
higher accuracy. The N7026A, when
used with an InfiniiVision or Infiniium
oscilloscope, provides highly-accurate,
low current waveforms for improved
debug and analysis.

Wide input range


It also has a wide input range, up to 30
Arms or 40 Apk. To achieve the widest
input range, you must use the external
AC power adapter that comes with Improved noise floor of the N7026A (yellow trace) over the N2893A (green trace)
the probe. Without the external power
adapter, you can achieve up to a 5 Arms
or 5 Apeak input range. The oscilloscope
will automatically synchronize with
the corresponding power source when
inserting or removing the AC adapter.
In either case, a degauss operation will
occur.

Degaussing made easy


For accurate measurement with a clamp-on
current probe, degaussing and eliminating
the offset error is critical. A degauss button
is included in the design of this probe. One
push of the button will perform a degauss
operation. Pushing and holding the button for
> 2 sec will perform a degauss and autozero
the DC offset. Whenever you are using the
degauss button, the current sensor should be
locked with no current flowing. Alternatively, N7026A current probe
the same operation can be performed from the
oscilloscope GUI.

Find us at www.keysight.com Page 26


Clamp-on Current Probes (Continued)
Characteristics of the 1146B Characteristics of N2780B Ordering information for
current probe Series current probes Keysight current probes
Bandwidth 1 dc to 100 kHz (–3 dB) Bandwidth (–3 dB) dc to 2 MHz (N2780B) 1146B 100-kHz current probe
Current range 1 100 mV/A:100 mA to dc to 10 MHz (N2781B) 1147B 50-MHz current probe with
10 A peak dc to 50 MHz (N2782B) AutoProbe interface
10 mV/A:1 to 100 A dc to 80 MHz (N2783L) N2893A 100-MHz current probe with
peak dc to 100 MHz AutoProbe interface
Output signal 1000 mV peak max (N2783A) N7026A 150-MHz high sensitivity current
AC current accuracy 1 Maximum current 500 A (N2780B) probe with AutoProbe interface
Range 100 mV/A (continuous) 150 A (N2781B) N2780B 2-MHz current probe
(50 mA to 10 A peak) 30 A N2781B 10-MHz current probe
Accuracy 3% of reading ± 50 mA (N2782B/83B/83L) N2782B 50-MHz current probe
Range 10 mV/A Maximum peak 700 A peak (N2780B) N2783L 80-MHz current probe with
(500 mA to 40 A peak) current (non- 300 A peak (N2781B) 5-m long cable
Accuracy 4% of reading ± 50 mA continuous) 50 A peak N2783B 100-MHz current probe
Range 10 mV/A (N2782B/83B/83L) N2779A 3-channel power supply for
(40 A to 100 A peak) Maximum input 300 V mains isolated N2780B/81B/82B/83B/83L
Accuracy (40 A to 100 A peak) voltage (N2782B/83B/83L)
15% max at 100 A 300 V CAT III, 600 V
Noise Range 10 mV/A: CAT II (N2780B/81B)
Output voltage rate 0.01 V/A (N2780B/81B) For more information about the
480 μV
0.1 V/A N2780B Series current probes, refer
Range 100 mV/A: 3 mV
(N2782B/83B/83L) to the Keysight N2780B Series current
Insertion impedance 0.01 Ω (50/60 Hz)
Amplitude accuracy ± 1.0 % rdg ± 500 mA probe data sheet, literature number
Maximum working 600 Vrms CAT II or 5989-6432EN.
voltage 300 Vrms CAT III (N2780B)
Maximum common 600 Vrms CAT II or ± 1.0 % rdg ± 100 mA
mode voltage 300 Vrms CAT III (N2781B)
± 1.0 % rdg ± 10 mA
Influence of < 0.2 mA/A AC
(N2782B)
adjacent conductor
± 1.0 % rdg ± 10 mA
Influence of < 0.2 mA/A AC
(N2783B/83L)
conductor position
Battery 9 V alkaline (NEDA
1604A, IEC 6LR61)
Low battery Green LED on when
≤ 6.5 V
Battery life 55 hours typical

Note: Reference conditions 23 ± 5 °C, (73.4


± 41 °C) 20 to 75% relative humidity, dc to 1 kHz,
probe zeroed, 1-minute warmup, batteries at
9 V + 0.1 V, external magnetic field < 40 A/m,
no dc component, no external current carrying
conductor, 1 MΩ/100 pF load, conductor
centered in jaw.

1.  Characteristics marked with asterisks are


specified performance. Others are typical
characteristics.

Find us at www.keysight.com Page 27


Clamp-on Current Probes (Continued)
Characteristics of the 1147B/N2893A/N7026A current probes
1147B/N2893A N7026A
Bandwidth (–3 dB) DC to 50 MHz (1147B) DC to 150 MHz
DC to 100 MHz (N2893A)
Rise time (calculated, 10% to 90%) 7 nsec (Tr = 0.35/BW) 2.67 nsec (Tr = 0.4/BW)
Maximum current (continuous) 15 Apeak, 15 ADC, 10 Arms 30 ADC, 30 Arms (with external power adapter)
30 Apeak, 30 ADC, 24 Arms (when one 5 ADC, 5 Arms (without external power adapter)
probe is used with InfiniiVision 3000XT,
5000/6000/7000 scope)
Maximum peak current (non-continuous) (for 30 Apeak 40 Apeak (when using external AC power adapter)
pulse-widths ≤ 10 µs) 32 Apeak (when one probe is used with 15 Apeak (without using external power adapter)
InfiniiVision 3000XT, 5000/6000/7000 scope)
Output voltage rate 0.1 V/A 1 V/A and 0.2 V/A, automatically switched by the
oscilloscope
Minimum oscilloscope vertical scale 10 mA/div 1 mA/div
Amplitude accuracy ± 1% rdg, ± 10 mA (DC or 45 to 66 Hz, rated ± 1% rdg. ± 5 mA to 30 Arms (including calibration
current) scale factor of oscilloscope measured at DC or 45
to 66 Hz)
Noise ≤ 2.5 mArms (for 20 MHz bandwidth measuring ≤ 250 µArms (for 20 MHz bandwidth measuring
instrument) instrument)
Temperature coefficient for sensitivity ± 2% or less (within a range of 0 to 40 °C or 32 to 104 °F)
Effect of external magnetic fields Equivalent to a maximum of 20 mA (in a DC to 60 Hz, 400 A/m magnetic field)
Maximum rated power 3 VA (with rated current)
Maximum input voltage 300 V mains isolated
Diameter of measurable conductors 5 mm dia. (0.2 in dia.)
Probe interface AutoProbe interface (1 MΩ terminated)
Cable lengths Appox. 1.5 m (59.0 in)
Maximum number of probes supported 2 (3000XT, 5000/6000/7000) 2 (3000XT, 5000/6000/7000 without external
power adapter)
4 (4000X, 6000X) 4 (3000XT, 5000/6000/7000 with external power
adapter)
4 (4000X, 6000X)

Find us at www.keysight.com Page 28


N7040A/41A/42A Rogowski Coil AC Current Probes
–  Easy-to-use clip-around coil enabling current measurement in confined space
–  Measure AC current up to 3,000 Apk (with N7040A)
–  Up to 30 MHz bandwidth (with N7041A/42A)

The N7040A Series Rogowski coil current probes are designed for measuring AC
currents ranging from a few 100 milliamps to 3,000 A from 3 Hz to > 30 MHz.

The probes have a thin, lightweight, flexible and simple-to-use clip-around Rogowski
coil that enables current measurement in the most difficult-to-reach parts and confined
spaces of a circuit under test and can measure large AC current without increase in
transducer size.

The N7040A Series is ideal for measuring AC current in the presence of large DC current
and can be used to design, debug and troubleshoot power semiconductor circuits,
power supplies, inverters and motor drives.

These probes come with an AC power adapter and 4x AA batteries to power the probe
and can be used with any oscilloscope with 1 Mohm BNC interface.

N7040A N7041A N7042A


HF bandwidth (—3 dB) 23 MHz 30 MHz 30 MHz
LF bandwidth (—3 dB) 3 Hz 12 Hz 9.2 Hz
Peak current (Apk) 3,000 Apk 600 Apk 300 Apk
Sensitivity 2 mV/A (500:1) 10 mV/A (100:1) 20 mV/A (50:1)
Max noise (mVpp) 8 mVpp 10 mVpp 15 mVpp
Droop (%/msec) 2.8%/msec 11%/msec 9%/msec
Peak di/dt (kA/usec) 80 kA/µsec 40 kA/µsec 20 kA/µsec
Absolute max peak di/dt (kA/µsec) 100 kA/µsec 100 kA/µsec 70 kA/µsec
Absolute max rms di/dt (kA/µsec) 1.2 kA/µsec 1.2 kA/µsec 1.2 kA/µsec
Accuracy Calibrated to ± 0.2% of reading with conductor central in the coil loop
Variation in conductor position ± 2% of reading
Linearity 0.05% of reading
DC offset ± 3 mV max at 25 ºC
Temperature range Coil and cable at —40 to +125 ºC
Coil voltage 5 kV peak 5 kV peak 1.2 kV peak
Coil length (circumference) 200 mm 100 mm 80 mm
Coil cross-section (diameter) 4.5 mm 4.5 mm 1.7 mm
Cable length 4 m (connecting cable coil to 2.5 m (connecting cable coil to integrator box)
integrator box)
Total cable length 4.5 m (4 m input cable + 0.5 m BNC 3 m (2.5 m input cable + 0.5 m BNC cable to scope)
cable to scope)
Probe output Terminated into 1 MΩ BNC input of oscilloscope
Probe power 4x AA batteries and AC power adapter (included)

Find us at www.keysight.com Page 29


High-sensitivity Current Probes
–  Measure AC/DC currents as low as Use an area-under-the-curve
50 µA measurement (Charge) on InfiniiVision
–  Ideal for capturing and analyzing oscilloscopes to easily calculate the
low level current flow in the DUT to integrated current consumptions over
characterize sub-circuits or measure time in Ah.
current consumption of battery-
powered devices or integrated The N2820A/21A high-sensitivity current
circuits probes are compatible with InfiniiVision
–  Simultaneous high- and low-gain 3000 X-, 4000 X- and 6000 X-Series
views of the current waveform for oscilloscopes.
more precise wide dynamic range
measurement (with N2820A)

As modern battery-powered devices and


integrated circuits become more green
and energy efficient, there is a growing
need to make high-sensitivity, low-level
current measurements to ensure the
current consumption of these devices
is in acceptable limits. The N2820A
high-sensitivity probe is engineered
to make high-dynamic-range, high-
sensitivity measurements to meet today’s
challenging current measurement needs.

The ultra-sensitive N2820A AC/DC


current probe can support measurements
from 50 µA to 5 A on Keysight
oscilloscopes. The N2820A interface uses
a make-before-break (MBB) connector,
allowing you to quickly probe multiple
locations on your DUT without having to
solder or unsolder the leads. The N2820A
2-channel current probe connects to
two oscilloscope channels to provide
simultaneous low-and high-gain views for
wider dynamic range measurement, while
The N2820A 2-channel current probe connects to two oscilloscope channels to provide
the N2821A 1-channel current probe simultaneous low- and high-gain views for wider dynamic range measurement
provides one user-selectable view at a
time.

Find us at www.keysight.com Page 30


High-sensitivity Current Probes (Continued)
Probe characteristics and specification
Bandwidth (–3 dB) Zoom-out channel: DC to 3 MHz
Zoom-in channel: DC to 500 kHz
Risetime (Tr = 0.35/bandwidth, 10 to 90%) Zoom-out channel: < 0.116 μs
Zoom-in channel: < 0.7 μsec
Minimum measurable current 1 250 μA (with N2822A 20 mΩ, 500 mW)
50 μA (with N2824A 100 mΩ, 500 mW)
5 mA (with N2825A user-defined 1 mΩ, 500 mW)
50 μA (with N2825A user-defined 1 kΩ, 500 mW)
Maximum measurable current 5 A (with N2822A 20 mΩ, 500 mW)
2.2 A (with N2824A 100 mΩ, 500 mW)
5 A 2 (with N2825A user-defined 1 mΩ, 500 mW)
1.2 mA 2 (with N2825A user-defined 1 kΩ, 500 mW)
DC amplitude accuracy ± 3% or 10 μA (whichever is greater)
Gain 3 Zoom-in channel: 300 ± 3%
Zoom-out channel: 1.97 ± 3%
Max input voltage ± 12 V
Output impedance 1 MΩ
Standard accessories 1 each 20 mΩ resistor sensor head
1 each 100 mΩ resistor sensor head
1 each user-defined resistor sensor head
5 each twisted leads (22 AWG) with sockets
5 each twisted leads (22 AWG) without sockets
5 each MBB headers
5 each MBB receptacles
1 each ground lead
1 each screw driver
1 each passive cable (with N2820A only)
1 each user guide manual (English)
Compatible InfiniiVision oscilloscopes InfiniiVision 3000 X-Series (with software version 2.30 or higher)
InfiniiVision 4000 X-Series (with software version 3.10 or higher)
InfiniiVision 6000 X-Series (with software version 6.00 or higher)
Max number of probes supported by 3000 X-Series Two N2820A probes using both pods or two N2821A probes
Max number of probes supported by 4000 X-Series Two N2820A probes using both pods, four N2820A probes using only the primary pod, or four
N2821A probes

1.  Vsupply is equal to 5 V, solder attached.


2.  Max current varies with max resistor power rating. The examples in the table assume 500 mW power rating.
3.  Denotes warrantied specification after 20-minute warm up. All others entries in the table are characteristics.

Ordering information for Keysight current probes


Model numbers Descriptions
N2820A High-sensitivity 2-ch current probe
N2821A High-sensitivity 1-ch current probe
Replacement part numbers
N2822A 20 mΩ resistor tips
N2824A 100 mΩ resistor tips
N2825A User-defined resistor tips
N2826A Replacement wires (15.5 cm, 22 AWG bare wires) (qty 5)
N2827A Passive cable (for N2820A secondary channel)
N2828A Replacement MBB (make before break) headers (qty 5)
N2829A Replacement MBB (make before break) receptacles and 15.5 cm, AWG 22 socketed wires (qty 5 each)

Find us at www.keysight.com Page 31


Wedge Probe Adapters
–  Easy connection to surface mount IC clip kits Ordering information
ICs E2613A 0.5 mm Wedge probe adapter,
–  Safe, with no chance of shorting An inexpensive solution for probing
fine-pitch ICs, the 10072A SMT kit 3 signal, qty 1
–  Mechanically non-invasive contact E2614A 0.5 mm Wedge probe adapter,
–  3-, 8-, and 16-signal versions includes 10 IC clips and 2 dual-lead
adapters that connect the clips directly to 8 signal, qty 1
–  Supports 0.5 and 0.65-mm E2643A 0.5 mm Wedge probe adapter,
–  TQFP and PQFP packages 10070-family probes.
16 signal, qty 1
The 10075A 0.5-mm IC clip kit is ideal E2615A 0.65 mm Wedge probe adapter,
Problem-free probing for connecting to ICs as fine as 0.5 mm. 3 signal, qty 1
The Keysight wedge probe adapter The clip body allows many clips to be E2616A 0.65 mm Wedge probe adapter,
eliminates many of the frustrations mounted side-by-side. The kit includes 8 signal, qty 1
associated with probing surface mount four 0.5-mm IC clips and two dual-lead E2644A 0.65 mm Wedge probe adapter,
components. If you have ever accidentally adapters that connect the IC clips directly 16 signal, qty 1
shorted IC pins together, experienced to 10070-family probes. 10072A SMT kit for 10070 probe family
electrical and/or mechanical problems 10075A 0.5 mm IC clip kit
with soldering small wires onto leads, or Keysight Wedge electrical
gotten frustrated juggling multiple probes characteristics
while you are trying to operate your
Operating < 40 Vdc + peak ac
scope, the Wedge was designed with you
voltage
in mind.
Operating 0.5 A maximum
current
Make the inaccessible Capacitance 2 pF typical (all except
accessible between Keysight-E2643A/44A)
contacts 4.33 pF typical at 1 MHz
When you use the Wedge, you do not
(Keysight-E2643A/44A)
have to worry about shorting IC pins
Self-inductance 15 nH typical (all except
together on a delicate component–or on
Keysight E2643A/44A)
an irreplaceable prototype. The Wedge
37 nH typical at 1 MHz
is easy to insert and it stays put. There is
(Keysight E2642A/44A)
no need to solder small wires onto leads.
Cross coupling –31 dB typical at 100 MHz
The Wedge is mechanically non-invasive,
(Keysight E2643A/44A)
so you will not damage the legs of the
Contact < 0.1 Ω
IC. Instead, you will have easy access to
resistance
hard-to-reach components.

Electrical reliability
The Wedge makes two contact points
with each leg of the IC. This redundant
physical connection increases the
electrical reliability of the connection. The
Wedge’s low capacitance and inductance
provides superior performance to many
other alternatives.

The Wedge probe adapter connects


directly to 1145A/1155A active probes
and the dual lead adapter provided with
the 1160A-65A passive probe family and
N2877A/N2879A accessory kits for use
with N287xA Series passive probes.

Find us at www.keysight.com Page 32


Miscellaneous Accessories
Testmobile Carrying cases Rackmount kit
The sturdy Keysight 1180CZ Testmobile The Keysight N6457A soft carrying case The Keysight N2916B rackmount kit
for use with 6000 Series oscilloscopes makes transporting and shipping your positions your 5000 and 6000 Series
makes sharing your scope easy. Its large 2000 X- and 3000 X-Series oscilloscope scope in the center of the rack. Each kit
wheels make it easy to roll from place safe and simple. An oscilloscope and includes a custom shelf with rails, six
to place. For use with the Keysight 6000 other accessories fit neatly inside the BNC pass-throughs and all necessary
Series scope, the 1180CZ Testmobile padded shell for shipment. For use with screws. For mounting the 7000 Series in
scope cart with the N2919A bracket the 7000, 4000 X-, and 6000 X-Series, the rack, order N2732A. For mounting
provides convenient mobility and secure order N2733B soft carrying case. all 2000 X- and 3000 X-Series in a rack,
mounting of your scope. order N6456A. For mounting any 4000
X-Series in a rack, order N2763A. For
mounting a 6000 X-Series in a rack, order
Specifications for the Keysight
the N2111A.
Testmobiles
1180CZ Ordering information
Total load 59 kg (130 lbs)
1180CZ Testmobile for 6000 Series
capacity
N2919A Bracket for 1180CZ Testmobile and
Tilt tray 45.7 cm wide x 45.7 cm deep
6000 Series scope
(18 in wide x 18 in deep)
N2917B Hard carrying case for 5000 and
6000 Series
N6457A Soft carrying case for 2000 X- and
3000 X-Series
N2760A soft carrying case for the 5000 Series N2733B Soft carrying case for 7000, 4000
X- and 6000 X-Series
N2760A Soft carrying case for 5000 Series
N2916B Rackmount kit for 5000 and 6000
Series
N2732A Rackmount kit for 7000 Series
N6456A Rackmount kit for 2000 and 3000
X-Series
N2763A Rackmount kit for 4000 X- Series
N2111A Rack mount kit for 6000 X-Series

N2733B soft carrying case for 7000, 4000 X-,


and 6000 X-Series

N2916B rackmount kit for 5000/6000 Series

Find us at www.keysight.com Page 33


Miscellaneous Accessories (Continued)
Probe positioners Ordering information
–  Easy-to-manipulate probe arms for Product number Description
hands-free browsing N2784A 1 1-arm probe positioner
–  One- or two-articulated arms with N2785A 1 2-arm probe positioner
stable high-mass base (N2784A and N2786A 2-leg probe positioner
N2785A) N2787A 3D probe positioner
–  Quick and stable XY positioning
1.  Includes 3x magnifying glass, arm strap,
(N2786A) cable tie, probe rest, and manual.
–  Stable 3D probe positioning for
hard-to-reach XYZ access (N2787A
–  Compatible with most scope probes
–  Applications: Hands-free browsing for
electronic components on PC board

The N2784A and N2785A probe


positioners provide quick and stable X-Y
positioning for PC boards and devices
that require hands-free probing.

Unlike other probe positioners that


require multiple adjustments to lock the
probe holder into position, the N2784A
and N2785A need only the “lift and
drop” motion to put the probe in place.
The weight stabilization technique used
in these probe holders keeps constant
pressure at the probing point so the probe
tip stays in position even when the target
board is bumped.
N2784A one-arm probe positioner
The N2786A is a low cost, easy-to-use
X-Y axis probe holder for general purpose
probing applications. The two-legged
positioner is designed to be easy to
use–the positioner itself has no controls
to position it in place.

The N2787A is a 3D probe positioner


with a flexible, articulating arm that
can be quickly positioned in a variety of
configurations.

For more information about Keysight’s N2786A 2-leg probe positioner N2787A 3D probe positioner
probe positioners, refer to literature
number 5989-9131EN.

Find us at www.keysight.com Page 34


T2A Probe Interface Adapter
–  Enables Tektronix TekProbe-BNC
level 2 probes to connect to
Keysight’s AutoProbe interface
on InfiniiVision 3000 X-, 4000 X-,
6000 X-, 5000, 6000, and 7000
oscilloscopes
–  An easy-to-use plug-on adapter
to the Keysight oscilloscope’s
AutoProbe interface
–  Provides necessary probe power,
calibration, and offset control as
needed to the attached TekProbe
probe
Single-ended active probes Keysight scope compatibility
The N2744A T2A interface adapter P6243 Single-ended active probe, 1 GHz, –  Keysight InfiniiVision 6000 X-Series
enables selected TekProbe interface 10:1 without offset control with software version 6.00 or higher
level 2 probes to be used with Keysight P6245 Single-ended active probe, –  Keysight InfiniiVision 3000 X-/4000
oscilloscopes with the AutoProbe 1.5 GHz, 10:1 with offset control X-Series with software version 1.10
interface. Existing TekProbe-BNC probe P6205 Single-ended active probe, or higher
types can simply be plugged into the T2A 750 MHz, 10:1 without offset –  Keysight InfiniiVision 5000, 6000,
adapter, which is then plugged directly control and 7000 Series and future revisions
into any AutoProbe input channel on an P6241 Single-ended active probe, 4 GHz, (except 6000 100-MHz) with
InfiniiVision or Infiniium oscilloscope. 10:1 with offset control software version 06.16 or higher
Select the probe model in the scope P6249 Single-ended active probe, 4 GHz,
menu and the Keysight oscilloscope sets 5:1 with offset control
up the attenuation factor and the probe Optical-to-Electrical Converters
type automatically. The T2A interface (works with InfiniiVision 5000,
adapter supplies the necessary probe Differential active probes
power, calibration (for selected models P5205 or Differential probe, 100 MHz, 6000 and 7000 with version
only), and offset control as used by the P5205A 50:1/500:1 with offset control 6.16 software only)
connected TekProbe probe. The adapter P5210 or Differential probe, 50 MHz, P6701B 1 GHz optical-to-electrical
is targeted for customers using both Tek P5210A 100:1/1000:1 with offset control converter with FC/PC connector
active probes with TekProbe-BNC level P6246 400 MHz, 10:1/1:1 with offset P6703B 1.2 GHz optical-to-electrical
2 interfaces and Keysight oscilloscopes control converter with FC/PC connector
with the AutoProbe interface. P6247 1 GHz, 10:1/1:1 with offset control P6711 250 MHz optical-to-electrical
P6248 1.5 GHz, 10:1/1:1 with offset converter
Tek probe compatibility control P6713 300 MHz optical-to-electrical
P6250 500 MHz, 50:1/5:1 with offset converter
The N2744A T2A adapter supports control
only the probes listed with TekProbe P6251 1 GHz, 50:1/5:1 with offset control
interfaces. Ordering information
N2744A T2A probe interface adapter
AC/DC current probe
TCP202 50-MHz AC/DC current probe

Find us at www.keysight.com Page 35


Recommended Probes for Low-/Mid-speed Bus Measurements
Applications Speed and signal type Recommended probe Required probe bandwidth
LIN 625 kbps, Single-ended SE passive (high Z) >50 MHz
ARINC 425 100 kbps, Differential N2792A/N2818A 200 MHz
CAN 2.0 5 Mbps, Differential N2792A/N2818A 200 MHz
CAN FD 10 Mbps, Differential N2792A/N2818A 200 MHz
MIL Std 1553 1 Mbps, Differential SE passive > 100 MHz
+/-25Vpp N2792A/N2818A 200 MHz > 100 MHz
I2S (audio) ~2.8 MHz, Single-ended SE passive (high Z) >100 MHz
I2C/SMbus <4 MHz, Single-ended SE passive (high Z) >100 MHz
RS232/UART <10 Mbps, Single-ended SE passive (high Z) >100 MHz
RS422/485 10 Mbps, Differential N2792A/N2818A 200 MHz
Flexray 10 Mbps, Differential N2792A/N2818A 200 MHz
SPI 1 – 100MHz, Single-ended SE passive (high Z) or N2795A >100 MHz passive or 1 GHz active
MOST 150 Mbps, Differential N2750A 1.5 GHz
USB2.0 480 Mbps, Differential N2750A 1.5 GHz
USB power delivery 300 kbps, Single-ended SE passive (high Z) >50 MHz

Find us at www.keysight.com Page 36


Keysight Oscilloscopes
Multiple form factors from 20 MHz to > 90 GHz | Industry leading specs | Powerful applications

Learn more at: www.keysight.com


For more information on Keysight Technologies’ products, applications or services,
please contact your local Keysight office. The complete list is available at:
www.keysight.com/find/contactus

Find us at www.keysight.com Page 37


This information is subject to change without notice. © Keysight Technologies, 2019 - 2020, Published in USA , July 10, 2020, 5968-8153EN