Self-priming multistage pumps 60 Hz
Contents
General data
Application Type key Pumped liquids Operating conditions Technical data Features and benefits Control panel Product range Page Page Page Page Page Page Page Page 4 4 4 4 4 4 5 5
Technical data
Material specification Flooded suction performance curves Dimensions Technical data MQ 3-35 suction lift performance curves MQ 3-45 suction lift performance curves Submittal data sheet Notes Page Page Page Page Page Page Page Page 6 7 7 7 8 9 10 11
Mission
General data
MQ
Application
The MQ pump is designed for water supply and pressure boosting ... homes cabbins, cottages on farms as well as gardens The pump is suitable for pumping of potable water and rain water.
Type Key
Example Pump range Rated flow [m/h] Max. head [m] Code for pump version A: Standard Code for pipework connection B: External thread Code for materials A: Standard Code for shaft seal MQ 3 -35 A - B - A -BVBP
Pumped liquids
Potable water, rain water or other clean, thin, non-aggressive liquids not containing solid particles or fibres.
Operating conditions
System pressure: Inlet pressure: Suction lift: Liquid temperature: Ambient temperature: Max. 109 psi (7.5 bar). Max. 44 psi (3 bar). Max. 26 ft (8 m). 32F to +95F (0C to +35C). 32F to +113F (0C to +45C).
Technical data
Mains voltage: 115 V models: 230 V models: Voltage tolerances: Enclosure class: Insulation class: Sound pressure level: Agency approvals: 1 x 110-120 V, 60 Hz 1 x 220-240 V, 60 Hz. 10%/+6%. IP54. B. 55 dB(A). UL, cUL
General data
MQ
5
TM01 9684 2600
Pos.
1 2
Function
ON/OFF button
Description
The Pump is started and stopped by means of the ON/OFF button. Indicates that the pump is ready for operation (green). Indicates that the pump is on standby (red). Indicates that the pump is running. Indicates that the auto reset function is active. After an alarm, restarting will be attempted every 30 minutes for a period of 24 hours. Indicates that the pump is in alarm state. Manual resetting is possible by pressing the ON/OFF button.
Alarm (red)
Product range
Region Pump Type
MQ 3-35 USA, Canada & Mexico MQ 3-45 MQ 3-35 MQ 3-45
Voltage
1 x 110 - 120 V
Connection
Power Cord w/plug Power Cord w/plug Power Cord w/plug Power Cord w/plug
1 x 220 - 240 V
Technical Data
MQ
Material specification
Pos. 2 4 7 10 14 16 42 49 65 92 100a 101 103 104 Components Motor stool with base plate Chamber Drain and priming plug Self-priming valve Self-priming part Pump sleeve Pressure tank Impeller Non-return valve Clamp Discharge port Suction port Shaft seal: Stationary and rotating part Shaft 150 Motor sleeve 174a 184 Pressure switch Flow sensor O-rings NBR-rubber Material POM + 25% glass fiber PPO + 20% glass fiber POM + 25% glass fiber PP + 30% glass fiber PPE/PS + 20 % glass fiber Stainless steel, DIN W.-Nr. 1.4301, AISI 304 Butyl (diaphragm) PPO + 20% glass fiber-PTFE POM + 25% glass fiber Stainless steel, DIN W.-Nr 1.4301, AISI 304 POM + 25% glass fiber POM + 25% glass fiber Carbon/ceramics/NBR rubber Stainless steel, DIN W.-Nr 1.4005, AISI 416 Stainless steel, DIN W.-Nr 1.4301, AISI 304 POM: Polyoximetylen NR-rubber: Natural Rubber PPO: Polyphenylene Oxides PP: Polypropylene PPE/PS: Polyphenylene Oxides (the same as PPO but from different supplier) NBR-rubber: Nitrile-Butadiene Rubber
Technical Data
MQ
-45
MQ 3
60 Hz
IS O 9906 A nnex A
H [m]
40
120
100
50
-35
40
32
80
30
24
60
40
20
0
20
16
10
0
0
0
4
12
16
20
Q [US GP M]
P1 P1 [hp] [kW]
1.0
1.2
0.8
0.6
0.4
-35 P1
20
15
0.8
Eta
10
5
0.4
0.2
0.0
0.0
12
16
20
Q [US GP M]
*See suction lift performance curves (page 8) for installations with water level below intake.
Dimensions
Technical data
Pump type MQ 3-35 MQ 3-45 MQ 3-35 MQ 3-45 Voltage 1 X 110-120 V 1 X 110-120 V 1 X 220-240 V 1 X 220-240 V In [A] 7.2 9.2 3.7 4.5 Istart [A] 12.5 12.5 8.6 8.6 P2 [W] 580 680 580 680 [hp] 0.79 0.92 0.79 0.92 Net weight [pounds] 29 29 29 29
Technical data
MQ
H [ft] p [psi]
110
45
MQ 3-35 model B
60 Hz
0 Ft
100
3.3 Ft
40
40
90
6.6 Ft
80
35
13.1 Ft
32
70
30
19.7 Ft
23.0 Ft
26.2 Ft
60
25
24
50
20
40
16
15
30
10
20
10
0
0
0
4
12
16
20
Q [US GP M]
Q [m/h]
Technical Data
MQ
H [ft]
140
p [psi]
60
MQ 3-45 model B
60 Hz
0 Ft 3.3 Ft
130
120
50
6.6 Ft
40
110
13.1 Ft
100
40
19.7 Ft
32
23.0 Ft
90
26.2 Ft
80
24
70
30
60
50
20
16
40
30
10
20
10
0
0
0
4
12
16
20
Q [US GP M]
Q [m/h]
MQ
Zip Code:
Example: MQ 3-35 NPSH required at duty point: Performance curve page number: Motor data page number:
10
Notes
MQ
11
Being responsible is our foundation Thinking ahead makes it possible Innovation is the essence
L-MQ-PG-001
7/04
PRINTED IN USA
Subject to alterations.
Canada GRUNDFOS Canada Inc. 2941 Brighton Road Oakville, Ontario L6H 6C9 Phone: (905) 829-9533 Telefax: (905) 829-9512 Mexico Bombas GRUNDFOS de Mexico S.A. de C.V. Boulevard TLC No. 15 Parque Industrial Stiva Aeropuerto C.P. 66600 Apodaca, N.L. Mexico Phone: 011-52-81-8144 4000 Telefax: 011-52-81-8144 4010
U.S.A. GRUNDFOS Pumps Corporation 17100 West 118th Terrace Olathe, Kansas 66061 Phone: (913) 227-3400 Telefax: (913) 227-3500
12
www.grundfos.com