Академический Документы
Профессиональный Документы
Культура Документы
28.04.2014
2014
1. ...................................................................................................................................................... 3
2. DTE/DCE ............................................................................................... 4
2.1. DTE/DCE .................................................................................................... 4
2.2. RS232 RJ45 (Cisco-compatible) ..................................... 5
2.3. RS232 RJ45 (NSG) .......................................................................... 6
2.4. RS232 DBH62f ............................................................. 8
2.5. V.35/V.24 DBH26f ................................... 10
2.6. V.24 sync DBH26f ................................................................... 14
2.7. IMX21, IMX212 .................................................................................................. 16
2.8. IM530 ...................................................................................................................... 18
2.9. V.24/V.35/X.21 DCE DBH26f ..................................................... 20
2.10. IM485, IM4852 .................................................................................................. 21
3. (xDSL) ........................ 24
3.1. xDSL .......................................................................................... 24
3.2. IMMDSL/xxx ........................................................................................................... 25
3.3. IMSRM, IMSRM2 ............................................................................................... 26
3.4. IDSL ............................................................................. 27
3.5. IMSDSL ................................................................................................................... 28
3.6. IMSHDSL ................................................................................................................ 29
3.7. IMxSHDSL/bis ........................................................................................................ 30
3.8. ........................................................................................ 32
4. ................................................................................................. 33
4.1. E1/G.703 ................................................................................................... 33
4.2. E1 . 19992001 . ................................................... 34
4.3. E1 . 2004 . ............................................................. 38
4.4. IM703/64xxx ............................................................................................................ 42
4.5. IM703 IM7032.................................................................................................. 44
4.6. RMBypass2E1 .......................................................................................................................... 45
5. Ethernet ......................................................................................................... 46
5.1. Ethernet 10/100BaseT .......................................................................................... 46
5.2. Ethernet 10BaseT ....................................................... 47
6. .............................................................................................................................. 49
6.1. IMGPRS h/w ver.1, 2 ............................................................................................... 49
6.2. IMGPRS h/w ver.3 ................................................................................................... 51
6.3. IMEDGE h/w ver.1, 2 .............................................................................................. 53
6.4. UIMEDGE h/w ver.3, 3a ......................................................................................... 55
6.5. UIM3G h/w ver.1 ..................................................................................................... 57
6.6. UIMCDMA UIMEVDO h/w ver.2 ..................................................................... 59
6.7. IMCDMA 1x h/w ver.1, ver.3 .................................................................................. 61
6.8. UMEVDO h/w ver.4 UIMEVDO h/w ver.6........................................................ 62
7. IMC1 ....................................................................................................................................................... 64
8. .................................................................................... 65
8.1. - IMDIO, IMDIO2.................................................................... 65
8.2. 1/2 ............................................................. 67
8.3. 1Wire IM1W.................................................................................................................. 68
9. DoC FLEX ............................................................................................................. 69
. ........................................................................ 70
. NSG ...................................................................................... 75
. - RS232 ............................... 77
"-c-" 20032014
NSG "-c-"
c
105187
. , .35
./: (+7495) 7271959 ()
rev.28.04.2014
1.
NSG900, NSG800, NX
300, NSG500, NPS7 ,
.
: NSG 1 2. 1 ( )
( ),
DBH26f . 2 ( )
DBH26f , ,
.
NSG700.
, NSG,
.
.
, , ,
.
NSG.
,
,
/ .
NSG :
,
,
,
NSG
900/maxU, NSG1000,
.
UMxxx,
NSG700, NSG1800, NSG:
M NSG700, NSG1800. .
IM1W NSG, 1Wire,
NSG:
M NSG. .
NSG:
NPS7e, NSG500, NX300, NSG800.
. . 3.
NSG. NSG Linux.
. 2.
NSG. NSG Linux 2.0.
. 2.
CD-ROM, ,
Web- NSG :
http://www.nsg.ru/doc/
ftp://ftp.nsg.net.ru/pub/doc/
rev.28.04.2014
2. DTE/DCE
2.1. DTE/DCE
DTE/DCE
NSG ,
(, ..), ,
, , NSG.
:
V.24/RS232
V.35 , .. DCE DTE ( TTC)
RS485 (- , "-" "")
RS530 , .. TTC DTE
X.21
RS232
, DTE/DCE ( ..
), NSG. (DTE/DCE),
,
. CABV24/D25/FC/A CAB
V24/D9/FC/A ( , ).
rev.28.04.2014
IMV24A
( )
RJ45
RJ45
1
2
3
4
5
6
7
8
DCE
CTS
DCD
RxD
GND
GND
TxD
DTR
RTS
DTE
RTS
DTR
TxD
GND
GND
RxD
DCD
CTS
DCE
RS232 async (Cisco-compatible)
CASV24/D9/FC/A, CASV24/D25/FC/A
NSG700
RJ45
DB9f DB25f
Control In 8
7
4
RTS
Ready In
7
4
20 DTR
Data In
6
3
2
TxD
GND
5
5
7
GND
GND
4
6
6
DSR
Data Out
3
2
3
RxD
Ready Out 2
1
8
DCD
Control Out 1
8
5
CTS
:
IMV24A Cisco Systems NPS
7e, NSG500, NX300, NSG800, NSG900.
DTE
RS232 async (Cisco-compatible)
CASV24/D25/MT/A, CASV24/D9/MT/A
NSG700
RJ45
DB9m DB25m
Control Out 1
7
4
RTS
Ready Out 2
4
20
DTR
Data Out
3
3
2
TxD
GND
4
5
7
GND
GND
5
6
Data In
6
2
3
RxD
Ready In
7
1
8
DCD
Control In 8
8
5
CTS
rev.28.04.2014
NPS7e, NSG5xx
NX300, NSG800
DCE
DTE
DCE
DTE
2
DCD
DTR
DCD ( ON) DTR ( ON)
3
TxD
RxD
TxD
RxD
4
DTR
DCD
5
RxD
TxD
RxD
TxD
6
CTS
RTS
CTS ( ON) RTS ( ON)
7
SG
SG
SG
SG
8
RTS
CTS
.
RS232
DCE
CABV24/D25/FC/A
CABV24/D9/FC/A
NSG
RJ45
DB9f DB25f
Data Out
5
2
3 RxD
Data In
3
3
2 TxD
Control Out 6
8
5 CTS
Control In 8
7
4 RTS
6
6 DSR
Ready Out 2
1
8 DCD
Ready In
4
4
20 DTR
SG
7
5
7
SG
DTE
CABV24/D25/MT/A
NSG
RJ45
DB25m
Data Out
5
2 TxD
Data In
3
3 RxD
Control Out 6
4 RTS
Control In 8
5 CTS
Ready Out
Ready In
SG
2
4
7
20 DTR
8 DCD
7
SG
:
NPS7e, NSG5xx, NSG700
.
NX300, NSG800, NSG900
. DCD, CTS ; DTR, RTS
UP. 9600 /,
.
rev.28.04.2014
NSG,
:
WAN 0 NX300/4Wx, NX300/8Wx
WAN 4 NSG800/4WL, NSG900/4WL
WAN DTE/DCE (.. IMV24, IM
V35x, IM530, IM485x, IMX21x),
:
WAN ;
, .
WAN ;
(2400, 4800, 9600 19200 /).
WAN , .
,
. ,
4 , .
WAN IMDIO2,
19200 /.
19200 /.
IMGPRS, UIMCDMA, UIMEVDO, UIMEDGE
. WAN ,
.
IMBT ( Bluetooth)
115200 /. 4 NSG800/4WL,
NSG900/4WL, 115200 /.
( ,
..),
WAN , .
4 NSG800/4WL, NSG900/4WL, 2 NSG800/WL h/w ver.2,
NSG900/2WL IMET10F, IMWIFI, xDSL Ethernet-over-WAN,
.
WAN , ,
.
,
WAN , , NSG
900/4WL card s4 empty PO:n TY:NOCONF (
), " ".
Telnet, PAD, ..
rev.28.04.2014
DBH62
1
22
44
43
23
45
24
2
25
3
47
46
4
Data Out
Data In
Flow Control Out
Flow Control In
Protective Ground
Signal Ground
Device Ready In
Device Ready Out
Data Out
Data In
Flow Control Out
Flow Control In
Protective Ground
5
26
6
27
49
48
28
50
29
7
30
8
52
51
9
32
10
31
Device Ready In
Device Ready Out
Data Out
Data In
Flow Control Out
Flow Control In
Protective Ground
Signal Ground
Device Ready In
Device Ready Out
Data Out
Data In
Flow Control Out
Flow Control In
Protective Ground
Signal Ground
Device Ready In
Device Ready Out
DBH26f
DBH26f
RJ45
18
CABOCT/ R45/A
CABOCT/D25/MT
-
-
6
TxD
2
TxD
3
RxD
3
RxD
8
RTS
4
RTS
1
CTS
5
CTS
1
1
4
PG
6
5
SG
7
SG
2
DCD
8
DCD
7
DTR
20
DTR
6
TxD
2
TxD
3
RxD
3
RxD
8
RTS
4
RTS
1
CTS
5
CTS
2
2
4
PG
6
5
SG
7
SG
2
DCD
8
DCD
7
DTR
20
DTR
6
TxD
2
TxD
3
RxD
3
RxD
8
RTS
4
RTS
1
CTS
5
CTS
3
3
4
PG
6
5
SG
7
SG
2
DCD
8
DCD
7
DTR
20
DTR
6
TxD
2
TxD
3
RxD
3
RxD
8
RTS
4
RTS
1
CTS
5
CTS
4
4
4
PG
6
5
SG
7
SG
2
DCD
8
DCD
7
DTR
20
DTR
.
rev.28.04.2014
33
11
54
53
12
55
13
34
14
35
57
56
36
58
37
15
38
16
60
59
17
Data Out
Data In
Flow Control Out
Flow Control In
Protective Ground
Signal Ground
Device Ready In
Device Ready Out
Data Out
Data In
Flow Control Out
Flow Control In
Protective Ground
Signal Ground
Device Ready In
Device Ready Out
Data Out
Data In
Flow Control Out
Flow Control In
Protective Ground
18
39
41
19
62
61
20
40
21
42
Device Ready In
Device Ready Out
Data Out
Data In
Flow Control Out
Flow Control In
Protective Ground
Signal Ground
Device Ready In
Device Ready Out
6
3
8
1
4
5
2
7
6
3
8
1
4
5
2
7
6
3
8
1
4
5
2
7
6
3
8
1
4
5
2
7
TxD
RxD
RTS
CTS
PG
SG
DCD
DTR
TxD
RxD
RTS
CTS
PG
SG
DCD
DTR
TxD
RxD
RTS
CTS
PG
SG
DCD
DTR
TxD
RxD
RTS
CTS
PG
SG
DCD
DTR
2
3
4
5
6
7
8
20
2
3
4
5
6
7
8
20
2
3
4
5
6
7
8
20
2
3
4
5
6
7
8
20
TxD
RxD
RTS
CTS
SG
DCD
DTR
TxD
RxD
RTS
CTS
SG
DCD
DTR
TxD
RxD
RTS
CTS
SG
DCD
DTR
TxD
RxD
RTS
CTS
SG
DCD
DTR
. DB25m CABOCT/D25/MT 6 .
DBH62m, DB25m.
CABD25/FDTE, CABD25/MMOD
CABD25/FDTE
CABD25/MMOD
NSG
NSG
RJ45f
DB25f
RJ45f
DB25m
CTS
1
4
RTS
CTS
1
5
CTS
DCD
2
20 DTR
DCD
2
8 DCD
RxD
3
2
TxD
RxD
3
3 RxD
PG
4
7 GND
PG
4
7 GND
SG
5
SG
5
TxD
6
3
RxD
TxD
6
2
TxD
DTR
7
6
DSR
DTR
7
20 DTR
8 DCD
RTS
8
4
RTS
RTS
8
5
CTS
:
CABOCT/D25/MT
DB25. DCE DB9 DTE , , - (. ).
CABOCT/R45/A RJ45
, Cisco Systems.
CABOCT/R45/A DTE DCE, , DB25.
.
RJ45 CABOCT/R45/A RJ
45 NSG700, IMV24
NPS7, NSG500, NX300, NSG800, NSG900.
rev.28.04.2014
10
IMV35 ( )
NSG 1, DBH26f
DB25f*
NSG 1
394215
10
IMV352
NSG 2
DBH26f
NSG700 h/w ver.5 s1
; h/w ver.6 s1
512 /,
s2 ;
NSG 2
396521
25
* NSG500 . .
( )
DBH26f
DBH26f
IMV35
IMV35N
DBH26f
DBH26f
DBH26f
IMV352
IMV35N2
IMV352
. 2003 .
rev.28.04.2014
11
V.24 async: 50*, 75*, 100*, 110*, 134*, 150*, 200, 300, 600, 1200, 1800, 2400, 4800, 9600, 19200,
38400, 57600, 115200, 230400*
V.24 sync:
V.35 sync:
600*, 1200*, 2400, 4800, 9600, 16000, 19200, 48000, 64000, 80000, 128000
600*, 1200*, 2400, 4800, 9600, 16000, 19200, 48000, 80000, 144000, 160000,
400000**, 784000**, 1168000** 640002048000** 64000;
3000000, 4000000, 5000000, 6000000, 7000000, 8000000 TTC*
DCE
,
DTE
:
5, 6, 7, 8
- 1, 1 ( NSG), 2
none, even, odd, mark, space
DBH26f, DB25f
DBH26f DB25f
V.35 sync
V.24 sync
DCE
DTE
DCE
DTE
1
19
SEL
2
3
RxD
TxD
3
2
TxD
RxD
4
5
CTS
RTS
CTS
RTS
5
4
RTS
CTS
RTS
CTS
6
8
DCD
DTR
DCD
DTR
7
7
SG
SG
SG
SG
8
20
DTR
DCD
DTR
DCD
9
1
PG
PG
PG
PG
10, 11
13, 25 TC/TTC (A, B) RC (A, B)
12, 13
12, 24
RC (A, B)
TC (A, B)
15, 14
11, 23
TxD (A, B)
RxD (A, B)
16
7
SG
SG
SG
SG
17
6
DSR
DSR
DSR
DSR
18
TTC
19, 20
10, 22
RxD (A, B)
TxD (A, B)
21, 22
9, 21
RC, TC (A, B) TTC (A, B)
23
14
RC in
TC in
24
16
TC in
RC in
25
15
Sync out
26
17
Sync out
V.24 async
DCE DTE
RxD
TxD
CTS
RTS
DCD
SG
DTR
PG
SG
DSR
Select V.35/V.24
Data Out
Data In
Flow Control Out
Flow Control In
Device Ready Out
Signal Ground
Device Ready In
Protective Ground
Receiver Clock In
Transmitter Clock In
Data In
SG Signal Ground
DSR Data Set Ready
Transmit Clock from DTE
Data Out
Clock Out
Transmitter Clock In
Receiver Clock In
Transmit Clock Out
Receive Clock Out
TxD
RxD
RTS
CTS
DTR
SG
DCD
PG
:
. IMV35N,
IMV35N2 IMV352 . 2003 . ( ) V.24 TTC ;
.
V.35 DCE 21, 22 DBH26f ( 9, 21 DB25f)
; DTE Transmit
Clock from DTE (TTC).
DSR .
rev.28.04.2014
12
DTE V.35
CABV35/M34/MT
M34f
A
PG
B
SG
D
C
H
E
F
CTS
RTS
DTR
DSR
DCD
Y
AA
V
X
P
S
R
T
A
TC
B
A
RC
B
A
TxD
B
A
RxD
B
NSG
DBH26m
PG
9
SEL
1
SG
7
SG
16
Control out 4
Control in 5
Ready in
8
DSR
17
Ready out 6
A 10
Sync in
B 11
A 12
Sync in
B 13
A
B
A
Data out
B
Data in
15
14
19
20
M34m
A
PG
B
C
D
F
E
H
V
X
Y
AA
R
T
P
S
SG
RTS
CTS
DCD
DSR
DTR
A
B
A
B
RC
TC
A
RxD
B
A
TxD
B
RC, TC , DCE,
(1990- ).
**
! CABV35/M34/FC, 2006 . ,
DBH26m 8 17.
. , NSG50 (IDSL)
17 DBH26m;
DTE.
NSG.
V.35 DBH26f (c TTC)
DCE V.35
CABV35/M34/FC/T
NSG
DBH26m
M34f
PG
9
A
PG
SEL
1
SG
7
B
SG
SG
16
Control out 4
D
CTS
Control in
5
C
RTS
Ready in
8
H
DTR
E
DSR
Ready out
6
F
DCD
U A
A 10
Sync in
TTC
B 11
W B
Y A
TC
AA B
V A
A 21
Sync out
RC
B 22
X B
P A
A 15
Data in
TxD
B 14
S B
R A
A 19
Data out
RxD
B 20
T B
DTE V.35
CABV35/M34/MT/T
NSG
DBH26m
M34m
PG
9
A
PG
SEL
1
SG
7
B
SG
SG
16
Control out 4
C
RTS
Control in
5
D
CTS
Ready in
8
F
DCD
Ready out
A
Sync in
B
A
Sync in
B
A
Sync out
B
A
Data in
B
A
Data out
B
rev.28.04.2014
6
10
11
12
13
21
22
15
14
19
20
H
V
X
Y
AA
U
W
R
T
P
S
DTR
A
RC
B
A
TC
B
A
TTC
B
A
RxD
B
A
TxD
B
13
V.35 DB25f ( )
DCE V.35
CA5V35/M34/FC
NSG
DB25m
M34f
PG
1
A
PG
SG
7
B
SG
SEL
19
Control out 5
D
CTS
Control in
4
C
RTS
Ready in
20
H
DTR
Ready out
8
F
DCD
DSR
6
E
DSR
A 9
V A
Clock out
RC
B 21
X B
Y A
TC
AA B
A 11
P A
Data in
TxD
B 23
S B
A 10
R A
Data Out
RxD
B 22
T B
DTE V.35
CA5V35/M34/MT
NSG
DB25m
PG
1
SG
7
SEL
19
Control out 5
Control in
4
Ready in
20
Ready out
8
A
B
A
TC in
B
A
Data in
B
A
Data Out
B
RC in
13
25
12
24
11
23
10
22
M34m
A
PG
B
SG
C
D
F
H
V
X
Y
AA
R
T
P
S
RTS
CTS
DCD
DTR
A
B
A
B
A
B
A
B
RC
TC
RxD
TxD
:
NX300/4Wx, NX300/8Wx 0
:
0 DTE (MODE:EXT).
0 DCE (MODE:INT); (600, 1200, 2400, 4800,
9600 19200 /).
0 ,
, " ".
NSG800/4WL, NSG900/4WL 4.
Transmit Clock from DTE ,
CABV35/M34/xx/T.
CABV35/M34/FC (DCE) MODE:TTC MODE:INT; CAB
V35/M34/MT (DTE) TTC DCE .
2048 / / 15
TTC. IMV35x.
V.24 . IMV24.
- NSG V.35 ( DBH26)
TTC
NSGDCE
NSGDTE
PG
9
9
PG
SEL
1
1
SEL
SG
7
7
SG
SG
16
16
SG
CTS
4
5
CTS
RTS
5
4
RTS
DTR
8
6
DTR
DCD
6
8
DCD
A 10
*
RC
B 11
A 12
12 A
*
TC
TC
B 13
13 B
Sync
A 21
10 A
RC
out
B 22
11 B
A 15
19 A
TxD
TxD
B 14
20 B
A 19
15 A RxD
RxD
B 20
14 B
*
C TTC
NSGDCE
NSGDTE
PG
9
9
PG
SEL
1
1
SEL
SG
7
7
SG
SG
16
16
SG
CTS
4
5
CTS
RTS
5
4
RTS
DTR
8
6
DTR
DCD
6
8
DCD
A 10
21 A
TTC
TTC
B 11
22 B
12 A
TC
13 B
A 21
10 A
Sync out
RC
B 22
11 B
A 15
19 A
TxD
TxD
B 14
20 B
A 19
15 A
RxD
RxD
B 20
14 B
RC, TC , DCE,
rev.28.04.2014
14
DCE
DTE DCE DTE
2
3
RxD
TxD
RxD TxD
3
2
TxD
RxD
TxD RxD
4
5
CTS
RTS
CTS RTS
5
4
RTS
CTS
RTS CTS
6
8
DCD
DTR DCD DTR
7
7
SG
SG
SG
SG
8
20
DTR
DCD DTR DCD
9
1
PG
PG
PG
PG
17
6
DSR
DSR DSR DSR
18
TTC
23
14
RC in
TC in
24
16
TC in
RC in
25
15
Sync out
26
17
Sync out
Data Out
Data In
Flow Control Out
Flow Control In
Device Ready Out
Signal Ground
Device Ready In
Protective Ground
Data Set Ready
Transmit Clock from DTE
Transmitter Clock In
Receiver Clock In
Transmit Clock Out
Receive Clock Out
:
IMV24N TTC .
DSR .
DSR, , .
.
rev.28.04.2014
( )
DBH26f
IMV24
DBH26f
IMV24N
15
V.24 (, ) DBH26f
DCE V.24
CABV24/D25/FC
NSG
DBH26m
DB25f
PG
9
1
PG
Data out
2
3 RxD
Data in
3
2 TxD
Control out 4
5 CTS
Control in 5
4 RTS
Ready out 6
8 DCD
DSR
17
6 DSR
Ready in
8
20 DTR
SG
7
7
SG
Sync in
23
15 TC
Sync out
25
Sync in
24
17 RC
Sync out
26
DTE V.24
CABV24/D25/MT
NSG
DBH26m
PG
9
Data out
2
Data in
3
Control out 4
Control in 5
Ready out 6
DSR
17
Ready in
8
SG
7
Sync in
23
TTC
18
Sync in
24
DB25m
1
PG
2 TxD
3 RxD
4 RTS
5 CTS
20 DTR
6 DSR
8 DCD
7
SG
15 TC
24 TTC
17 RC
V.24 (, ) DB25f ( )
DCE V.24
CA5V24/D25/FC
NSG
DB25m
DB25f
PG
1
1
PG
Data in
2
2 TxD
Data out
3
3 RxD
Control in 4
4 RTS
Control out 5
5 CTS
DSR
6
6 DSR
SG
7
7
SG
Ready out 8
8 DCD
Ready in
20
20 DTR
Sync out
15
15 TC
Sync out
17
17 RC
DTE V.24
CA5V24/D25/MT
NSG
DB25m
PG
Data in
Data out
Control in
Control out
1
2
3
4
5
DB25m
1
PG
3 RxD
2 TxD
5 CTS
4 RTS
SG
Ready out
Ready in
Sync in
Sync in
7
8
20
14
16
7
SG
20 DTR
8 DCD
15 TC
17 RC
:
-
NSG V.24
NX300/4Wx, NX300/8Wx WAN 0
( DBH26)
:
NSGDCE
NSGDTE
0 DTE (MODE:EXT).
PG
9
9
PG
0 DCE (MODE:INT);
RxD
2
3
RxD
(600, 1200, 2400, 4800,
TxD
3
2
TxD
9600 19200 /).
CTS
4
5
CTS
0
RTS
5
4
RTS
.
DCD
6
8
DCD
NSG800/4WL, NSG900/4WL
DTR
8
6
DTR
4.
SG
7
7
SG
RC
23
23
RC
0 ,
Sync out 25
,
TC
24
24
TC
" ".
Sync out 26
,
Eicon ( DTE, DB25f)
, CAxV24/D25/FC ( ), DB25m ("").
CAxV24/D25/FC (--) DB25 "-".
! CABV24/D25/FC, 2006 . , DBH26m 8 17.
. , NSG50 (IDSL)
17 DBH26m;
DTE.
NSG.
rev.28.04.2014
16
IMX212
NSG 1, DBH26f
NSG 2,
DBH26f
NSG700 h/w ver.6 s1, 512 /
NSG 1
NSG 2
394215
406516
10
25
: DTE/DCE NSG
:
X21 ( NSG Linux 1.0 card sN im-x21)
EXT DTE
INT DCE
, ,
(DTE DCE).
600*, 1200*, 2400, 4800, 9600, 16000, 19200, 48000, 80000,
144000, 160000, 400000, 784000, 1168000 640002048000 64000 / ( DCE
, DTE )
600 1200 / NSG500; 512 / NSG700
DBH26f
DCE
DTE
17, 18
RxD (A,B)
TxD (A,B) Data Out
14, 15
TxD (A,B)
RxD (A,B) Data In
12, 13
SIn (A,B) Transmit Clock In
23, 24
SOut (A,B)
Transmit Clock Out
25, 26
C (A,B)
C (A,B)
Control Out
10, 11
I (A,B)
I (A,B)
Indication In
7
SG
SG
Signal Ground
9
PG
PG
Protective Ground
:
.
.
.
( )
IMX212
DBH26f
IMX21
DBH26f
rev.28.04.2014
17
X.21
DCE X.21
CABX21/D15/FC
NSG
DBH26m
DB15f
A 17
4 A
Data out
RxD
B 18
11 B
A 14
2 A
Data in
TxD
B 15
9 B
A 23
6 A
S-out
S
B 24
13 B
A 25
5 A
C
I
B 26
12 B
A 10
3 A
I
C
B 11
10 B
SG
7
8
SG
PG
9
1
PG
DTE X.21
CABX21/D15/MT
NSG
DBH26m
A 17
Data out
B 18
A 14
Data in
B 15
A 12
Sin
B 13
A 25
C
B 26
A 10
I
B 11
SG
7
PG
9
DB15m
2 A
TxD
9 B
4 A
RxD
11 B
6 A
S
13 B
3 A
C
10 B
5 A
I
12 B
8
SG
1
PG
:
NX300/4Wx, NX300/8Wx WAN 0
:
0 DTE (MODE:EXT).
0 DCE (MODE:INT); (600, 1200, 2400, 4800,
9600 19200 /).
0 ,
, " ".
NSG800/4WL, NSG900/4WL 4.
IMX21 NSG500, 1
DB25f, .
- NSG X.21 ( DBH26)
NSGDCE
A 17
RxD
B 18
A 14
TxD
B 15
A 23
S
B 24
A 25
I
B 26
A 10
C
B 11
SG
7
PG
9
NSGDTE
14 A
RxD
15 B
17 A
TxD
18 B
12 A
S
13 B
10 A
I
11 B
25 A
C
26 B
7
SG
9
PG
rev.28.04.2014
18
2.8. IM530
: TIA/EIA RS530
: NRZ
:
: DTE
DCE
, : NSG 1, DBH26f
:
: NSG 1 DBH26f
: 394319
: 10
: DTE/DCE NSG
:
RS530 ( NSG Linux 1.0 card sN im-530)
EXT DTE
INT DCE
, ,
(DTE DCE).
600*, 1200*, 2400, 4800, 9600, 16000, 19200, 48000, 80000, 144000, 160000, 400000, 784000,
1168000 640002048000 64000 / ( DCE ,
DTE )
* 600 1200 / NX300, NSG800
DBH26f
RS530
DCE
DTE
3, 12
RxD (A,B)
TxD (A,B)
20, 19
TxD (A,B)
RxD (A,B)
5,14
CTS (A,B)
RTS (A,B)
10, 1
RTS (A,B)
CTS (A,B)
4,13
DCD (A,B)
DTR (A,B)
24, 23
DTR (A,B)
DCD (A,B)
26, 25
RC-in (A,B)
22, 21
TC-in (A,B)
17, 8
RC-out (A,B)
11, 2
TC-out (A,B)
TTC (A,B)
7
9
SG
PG
SG
PG
Data Out
Data In
Flow Control Out
Flow Control In
Device Ready Out
Device Ready In
Receive Clock In
Transmit Clock In
Receive Clock Out
Transmit Clock Out/
Transmit Clock from DTE
Signal Ground
Protective Ground
:
DSR .
DSR, ,
.
.
.
DCE 11, 2 Transmit
Clock. V.35 Transmit
Clock from DTE.
.
rev.28.04.2014
( )
DBH26f
J10
J11
J12
J13
J2
J3
J4
12
19
RS530
DCE RS530
CAB530/D25/FC
NSG
DBH26m
DB25f
A 3
3 A
Data out
RxD
B 12
16 B
A 20
2 A
Data in
TxD
B 19
14 B
A 5
5 A
Control out
CTS
B 14
13 B
A 10
4 A
Control in
RTS
B 1
19 B
A 24
20 A
Ready in
DTR
B 23
23 B
A 4
8 A
Ready out
DCD
B 13
10 B
6 A
DSR
22 B
A 17
17 A
RC out
RC
B 8
9 B
A 11
15 A
TC out
TC
B 2
12 B
SG
7
7
SG
PG
9
1
PG
-
NSG
RS530 ( DBH26)
NSGDCE
NSGDTE
A 3
20 A
RxD
RxD
B 12
19 B
A 20
3 A
TxD
TxD
B 19
12 B
A 5
10 A
CTS
CTS
B 14
1 B
A 10
5 A
RTS
RTS
B 1
14 B
A 24
4 A
DTR
DTR
B 23
13 B
A 4
24 A
DCD
DCD
B 13
23 B
A 17
26 A
RC
RC
B 8
25 B
A 11
22 A
TC
TC
B 2
21 B
SG
7
7
SG
PG
9
9
PG
DTE RS530
CAB530/D25/MT
NSG
DBH26m
A
Data out
B
A
Data in
B
A
Control out
B
A
Control in
B
A
Ready in
B
A
Ready out
B
A
RC in
B
A
TC in
B
A
TTC
B
SG
PG
3
12
20
19
5
14
10
1
24
23
4
13
26
25
22
21
11
2
7
9
DB25m
2 A
TxD
14 B
3 A
RxD
16 B
4 A
RTS
19 B
5 A
CTS
13 B
8 A
DCD
10 B
20 A
DTR
23 B
17 A
RC
9 B
15 A
TC
12 B
24 A
TTC
11 B
7
SG
1
PG
:
NX300/4Wx, NX300/8Wx WAN 0
:
0 DTE (MODE:EXT).
0 DCE (MODE:INT);
(600, 1200, 2400, 4800, 9600
19200 /).
0 ,
,
" ".
NSG800/4WL, NSG900/4WL
4.
IM530 NSG500,
1
DB25f, .
IM530 TTC
DTE, .
rev.28.04.2014
20
V.35 DCE
V.24 DCE
X.21 DCE
CTS
RTS
DCD
SG
DTR
PG
RxD
TxD
CTS
RTS
DCD
SG
DTR
PG
TxD (A, B)
SG
SG
SG
PG
C (A,B)
TxD (A,B)
I (A,B)
RxD (A,B)
SOut (A,B)
RxD (A, B)
RC, TC (A, B)
Sync out
Sync out
Select V.35/V.24
Data Out
Data In
Flow Control Out
Flow Control In
Device Ready Out
Signal Ground
Device Ready In
Protective Ground
Control In
Data In
Signal Ground
Indication Out
Data Out
Clock Out
Transmit Clock Out
Receive Clock Out
X.21 DCE
CASX21/D15/FC
NSG50
DBH26m
DB15f
A 19
4 A
Data out
RxD
B 20
11 B
A 15
2 A
Data in
TxD
B 14
9 B
A 21
6 A
S-out
S
B 22
13 B
A 18
5 A
C
I
B 17
12 B
A 11
3 A
I
C
B 10
10 B
SEL
1
SG
7
8
SG
PG
9
1
PG
:
.
. .
rev.28.04.2014
21
10
25
FD.
rev.28.04.2014
22
( ),
IM485. .
.
MASTER
SLAVE. SLAVE MASTER,
SLAVE MASTER;
MASTER, SLAVE.
.
SLAVE , SLAVE "" MASTER.
IM485
DBH26f
HD.
"" ,
,
.
"-"
- .
.
RS485 DBH26f
( )
15, 14
RxD (A, B)
19, 20
TxD (A, B)
24
SG
1, 7
()
5, 6
()
21, 22
()
( )
Receive Data
In
Transmit Data
Out
Signal Ground
(Half Duplex or Slave mode)
(RxD )
(TxD )
:
.
.
.
.
rev.28.04.2014
IM4852
DBH26f
23
RS485
NSG
A
RxD
B
A
TxD
B
SG
15
14
19
20
24
1
HD mode
7
5
RxD-term.
6
21
TxD-term.
22
FD
Master
Slave
A
TxD
B
A
RxD
B
SG
DBH26m
DBH26m
FD
Master
Master
A
TxD
B
A
RxD
B
SG
DBH26m
DBH26m
15
14
19
20
24
1
HD mode
7
5
RxD-term.
6
21
TxD-term.
22
15
14
19
20
24
1
HD mode
7
5
RxD-term.
6
21
TxD-term.
22
NSG
A
RxD
B
A
TxD
B
SG
15
14
19
20
24
1
HD mode
7
5
RxD-term.
6
21
TxD-term.
22
HD
A
RxD/TxD
B
SG
, Half
Duplex, RxD-terminator, TxD-terminator,
IM485.
, ()
DBH26M,
DBH26F
NSG.
,
()
.
DBH26m
DBH26m
15
14
19
20
24
1
HD mode
7
5
RxD-term.
6
21
TxD-term.
22
Master
A
TxD
B
A
RxD
B
SG
HD
HD
NSG
A
RxD
B
A
TxD
B
SG
Slave
A
TxD
B
A
RxD
B
SG
FD
Slave
FD
Slave
NSG
A
RxD
B
A
TxD
B
SG
NSG
A
RxD
B
A
TxD
B
SG
NSG
A
RxD
B
A
TxD
B
SG
15
14
19
20
24
1
HD mode
7
5
RxD-term.
6
21
TxD-term.
22
HD
A
RxD/TxD
B
SG
HD mode RxD-term. TxD-term.
Full Duplex, MASTER
Full Duplex, SLAVE
Full Duplex, MASTER
Half Duplex
Half Duplex
IM485
rev.28.04.2014
24
3. (xDSL)
3.1. xDSL
NSG
(, ..) (xDSL).
:
SRM
Mitel
IDSL
ITUT G.961
MDSL
Level One
SDSL
Conexant
SHDSL
ITUT G.991.2 (Annex A, B)
SHDSL.bis ITUT G.991.2 (Annex A, B, F, G), G.994
V.34/V.92
().
xDSL NSG 2
DBH26f. RJ45 RJ12. (
IMSRM, NSG 1,
DBH26f , DBH26/RJ45).
xDSL .
rev.28.04.2014
3.2. IMMDSL/xxx
: IMMDSL/400, IMMDSL/784, IMMDSL/1168
: Level One
: 2B1Q
: 1
: ,
25
/
0,5 (24 AWG) 0,4 (26 AWG)
IMDSL/400
400
5,4
3,8
IMDSL/784
784
4,4
3,1
IMDSL/1168
1168
3,7
2,6
:
:
: NSG 2, RJ45 .
RJ11 RJ12.
: NSG5xx, NX300/xx2, NSG800/xx, NSG900/xx NSG 2
NX300/xx4 37
( 3 NX300 1 )
:
389327
:
30
/ : 1500
: 230 , 125
:
:
MDSL ( DSL)
MASTER SLAVE; , ,
400000, 784000, 1168000 / ( )
( )
RJ45
RJ45
4, 5
Tip, Ring
:
RJ11 2, 3.
RJ12 3, 4.
J4 ,
.
rev.28.04.2014
26
: Mitel
: Bi-Phase; NSM160 ( )
: 1
: 0,5 (24 AWG) 6,5
0,4 (26 AWG) 4,7
: 80 160 /. .
:
:
IM SRM
NSG 1, DBH26f ;
CABSRM
NSG 1
395324
20
IM SRM 2
NSG 2, RJ45 .
RJ11.
NSG 2,
NSG700
396027
30
/ : 1500
: 230 , 125
: LEC
:
SRM
MASTER SLAVE; , ,
80000 160000 / ( )
( )
DBH26f
J2
J1, J2 :
80 / J1, J2
160 / J1, J2
J3 LEC:
LEC off 12, 34, 67, 910
LEC on 12, 45, 78, 1011
RJ45
J2
J3
J3
J1
J1
IMSRM
IMSRM
DBH26f
2, 3
Tip, Ring
SRM
RJ45
4, 5
Tip, Ring
: RJ11
DBH26m RJ45 :
2
4
RJ114: 2, 3
3
5
RJ116: 3, 4
IMSRM IMSRM2 LEC (Loop Extender
Circuit). LEC SRM 1 ,
. LEC (off)
(on) .
0,4 0,5 .
!
LEC ,
,
,
500 900
80 /
0,4
0,5
LEC
03,8
05,3
LEC
0,654,7 0,96,5
rev.28.04.2014
160 /
0,4
0,5
03,2
04,6
0,54,2 0,655,2
27
3.4. IDSL
: IMIDSL
NSG504/Voice ( )
IM4xIDSL NSG800/maxI ( )
: ITUT G.961. IDSL .
: 2B1Q
: 1
: 0,5 (24 AWG) 8,0
0,4 (26 AWG) 6,0
: 192 /
: IMIDSL B1, B2, D
NSG504/Voice IM4xIDSL B1, B2 ( )
:
IMIDSL 16, 64, 80, 128, 144 /; NSG504/Voice IM4xIDSL 128
64 / ( ).
, .
IMIDSL:
. :
NSG 2, RJ45 . RJ11
RJ12.
NSG5xx, NX300/xx2, NSG800/xx, NSG900/xx NSG 2
NX300/xx4 37 ( 3 NX300
1 )
NSG700 h/w ver.6 , s1
388527
30
/ : 1500
: 230 , 125
: IMIDSL
NSG504/Voice IM4xIDSL 64/128 /
NSG504/Voice IMIDSL IDSL-
"Data Only" (
OFF), / 128 /
:
IDSL
MASTER SLAVE; IM4xIDSL MASTER. ,
, .
IMIDSL 16000, 64000, 80000, 128000, 144000 / ( )
NSG504/Voice IM4xIDSL 128 000 /
IMIDSL
JM1 B1, B2, D:
( )
RJ45
J8 ,
,
/
16
64
80
JM1
128
144
RJ
12
D
B1
B2
B1+D
B2+D
B1+B2
B1+B2+D
JM1
D
B1, B2
B1
B2, D
B2
B1, D
B1, D
B2
B2, D
B1
B1, B2
B1, B2, D
.
64 80 /
-
B1
B2.
RJ45
J8
: RJ11
4, 5
Tip, Ring 2, 3, RJ12 3,4
rev.28.04.2014
28
3.5. IMSDSL
: Conexant
: h/w ver.1 ( -), ver2. h/w ver.2
h/w ver.1 , , Ethernet-over-SDSL.
.
: NSG200/V35C ( -) 192 / ;
Conexant,
ATM-over-SDSL, E1-over-SDSL ..;
NSG50 SDSL Ethernet h/w ver.2
: NSG700/4AU, NSG700/8A, NSG700/12A 1,
NSG800, NSG900 ( ), NX300/4W4 0, NX300/2WL 1
: 2B1Q
: 1
: 1442320 / ( 8 /)
:
:
,
144
7,2
6,0
272
6,9
5,2
400
6,2
4,7
, /
528
784 1040 1168 1552
5,7
5,4
5,0
4,8
4,4
4,5
4,2
4,0
3,9
3,7
1808
4,0
3,5
2064
3,8
3,0
2320
3,2
2,7
:
: NSG 2, RJ12 ( RJ11)
: NSG5xx, NX300/xx2, NSG800/xx, NSG900/xx NSG 2
NX300/xx4 37 ( 3 1
)
NSG700/4AU, NSG700/8A, NSG700/12A s1 (h/w ver.5
Ethernet; h/w ver.6 HDLC, .512 /; h/w ver.6m, 6u )
:
388626
:
25
/ : 1500
( )
: 230 , 125
RJ12
:
2B1Q (/)
BER-
:
:
SDSL
MASTER SLAVE
:
2B1Q (, )
2B1Q_S (, )
144000 2320000 /, 8000 /
( )
, ,
,
.
:
SERVICE
SDSL
MASTER SLAVE
:
ALTERA EPM7032S h/w ver.1
2B1Q ( , )
ALTERA EPM7064S h/w ver.2
2B1Q_S ( , )
144000 2320000 /, 8000 /
( )
RJ12
:
FLB (Far LoopBack)
3.6. IMSHDSL
29
264
6,7
456
6,6
, /
584
712
904
968 1224 1672 1864
6,4
6,2
6,1
5,5
5,4
5,3
5,2
2056
4,9
2312
4,6
. .
, , ,
,
, .
:
: NSG 2, RJ12 ( RJ11)
: NSG5xx, NX300/xx2, NSG800/xx, NSG900/xx NSG 2
NX300/xx4 37
( 3 NX300 1 )
:
389929
:
30
/ : 1500
: 230 , 125
:
( )
RJ12
:
:
SHDSL
COE CPE
2002312 2082320 / ( 64 /)
( )
(Annex A/B) _A _B
, ,
, .
:
SERVICE
SHDSL
COE CPE
2002312 2082320 / ( 64 /)
( )
(Annex A/B) _A _B
: FLB (Far LoopBack)
, ,
, .
BER .
RJ12
3, 4
Tip, Ring
. RJ11
2, 3.
:
, .
NX300, (
IV . 2004 .) .
rev.28.04.2014
30
3.7. IMxSHDSL/bis
: IMSHDSL/bis, IM2SHDSL/bis
: ITUT G.991.2 (Annex A, B, F, G), G.994
c
:
TDM
TDM
Ethernet-over-HDLC
: TCPAM 32, TCPAM 16 (
)
: 1 2
: 1925696 / ( 64 /)
:
: ,
: NSG 2, () RJ12
( RJ11)
:
NSG900/8WL
3, 4, A31, A41
NSG900/4WL, NSG800/4WL
3, 4
NSG900/16A, NSG800/16A
1, 2
NSG900/2WL, NSG800/WL h/w ver.2.2 12, 2
NSG800/WL h/w ver.2.1
12 23
1
2
3
.
unframed Ethernet-over-HDLC.
TDM.
:
389929
:
30
/ : 1500
: 230 , 125
:
:
RJ12
. RJ11
3, 4
Tip, Ring 2, 3.
rev.28.04.2014
RJ12
RJ12
IM_SHDSL3
,
, TCPAM 16 TCPAM 32 TCPAM 16 TCPAM 32
/
@0,4 2
@0,4 2
@0,5 2
@0,5 2
5696
2,4
3,0
5120
2,8
3,5
4608
3,3
4,1
4096
3,7
4,6
3848
3,9
4,7
3584
4,0
5,0
3072
4,3
5,4
2560
4,6
5,8
2304
5,1
6,4
2048
5,3
5,1
6,6
6,4
1792
5,4
6,8
1536
5,6
7,0
1280
5,8
7,3
1024
6,1
5,8
7,6
7,3
768
6,9
6,0
8,6
7,5
512
7,3
9,1
384
7,6
9,5
256
>8
>10
192
>8
>10
IM2SHDSL/bis
( )
J1
J1
,
.
IMSHDSL/bis
(
) .
:
:
DSL-.
rev.28.04.2014
31
32
3.8.
: IMV92 ( ), IMV34
:
: ITUT V.92*, V.34, V.32bis, V.32, V.23, V.22bis, V.22, V.21;
Lucent Technologies & Rockwell Semiconductor Systems K56Flex*; Bell 212, 103
: ITUT V.44, V.42bis
: ITUT V.42; Microcom MNP 5, MNP 10
:
:
: NSG 2, RJ12 ( RJ11)
: NSG5xx, NX300/xx2, NSG800/xx, NSG900/xx NSG 2;
NSG7xx s1; NX300/xx4 37
( 3 NX300 1 )
:
Bell 103
Bell 212
V.21
V.22
V.22 bis
V.23
V.32
V.32 bis
V.34
56K*
V.90* ""
V.92* ""
V.92* "-"
, /
300
1200/75 75/1200
300
1200
2400, 1200
1200
9600, 4800
14400, 12000, 9600, 7200, or 4800
33600, 31200, 28800, 26400, 24000, 21600, 19200, 16800, 14400, 12000, 9600, 7200, 4800, 2400
56000, 54000, 52000, 50000, 48000, 46000, 44000, 42000, 40000, 38000, 36000, 34000, 32000
56000, 54667, 53333, 52000, 50667, 49333, 48000, 46667, 45333, 44000, 42667, 41333, 40000,
38667, 37333, 36000, 34667, 33333, 32000, 30667, 29333, 28000
56000, 54667, 53333, 52000, 50667, 49333, 48000, 46667, 45333, 44000, 42667, 41333, 40000,
38667, 37333, 36000, 34667, 33333, 32000, 30667, 29333, 28000
48000, 46667, 45333, 44000, 42667, 41333, 40000, 38667, 37333, 36000, 34667, 33333, 32000,
30667, 29333, 28000, 26667, 25333, 24000
* IMV92.
( )
:
:
/ : 1500
: 230 , 125
: 369021
: 25
:
J1
DTR ( ) NSG
( DTR
)
( / )
:
V24 ( NSG), im-v24 (NSG Linux 1.0),
rs-232 (NSG Linux 2.0)
300, 1200, 2400, 4800, 9600, 19200, 38400, 57600,
115200, 230400 / ( )
: 1 , ( DCD ).
RJ12
. 2-
3- :
3, 4
Tip, Ring
B/O XL34 IMV34
. RJ11
B/O XL92 IMV92
2, 3.
IM_V.34
RJ12
J1
: 23
.
-. . , .
rev.28.04.2014
33
4.
4.1. E1/G.703
(PDH)
NSG .
NPS7e, NSG500, NX300, NSG700, NSG800, NSG900
PDH:
E0* (64 /, G.703.1, DS0)
E12* (2048 / unframed, G.703.6)
E1, (Fractional E1)
E1,
(Channelized E1)
Fractional E1 drop-and-insert
.
PDH NSG 2, RJ45
DBH26f.
E1 2,
NSG.
( IM703, NSG 1,
DBH26f , DBH26/RJ45).
.
rev.28.04.2014
34
4.2. E1
. 19992001 .
rev.28.04.2014
35
NX300/3WL2
NX300/4W2
NX300/7WL4
2
NX300/8W4
NX300/3WLMH2
NSG800/4WL2 h/w v.1
3L, 4
NSG900/4WL2 h/w v.1
NSG800/16A h/w v.1.2
1L, 2
NSG900/16A h/w v.2
NSG800/WL h/w v.1
1
NSG800/maxI16
2
NX300/3WL2
NX300/4W2
1+2
NX300/3WLMH2
NSG800/4WL2 h/w v.1
3+4
NSG900/4WL2 h/w v.1
NSG800/16A h/w v.1.2
1+2
NSG900/16A h/w v.2
NX300/3WLMH2
2 ()
NSG800/4WL2 h/w v.1
3
NSG900/4WL2 h/w v.1
NSG800/16A h/w v.1.2
1
NSG900/16A h/w v.2
IME1
IME1SS
IM2E1
IMCE1
NSG520
, ,
WAN
IF:0 PO:2
4118727
40
4014827
35
7818727
75
4118727
40
IF:0 PO:4
IF:0 PO:2
IF:0 PO:1
IF:0 PO:2
IF:0 PO:1
IF:1 PO:2
IF:0 PO:3
IF:1 PO:4
IF:0 PO:1
IF:1 PO:2
IF:0 PO:316
IF:0 PO:434
IF:0 PO:232
IF:1 PO:1
IF:2 PO:2
NSG
E1. NSG Linux (L) IM
E1 IME1 IMCE1 .
IM2E1 .
,
. NX300 ;
NSG800 3.
.
0
CPU
board
MC68
EN360
NX300
NSG800/4WL
NX300/3WLMH2 ,
IMCE1 ,
2 ( ). 14 . ( ).
NX300/3WL.
IM2E1 NSG800/4WL2, III . 2003 .
, IME1SS NSG800/WL h/w ver.1 ( )
.
.
NSG mailto:support@nsg.net.ru ,
.
rev.28.04.2014
36
IMxE1 ( )
IF:0
IF:0
IF:1
IF:0
RJ45
RJ45
RJ45
RJ45
J5
IME1, IMCE1
IM2E1
IME1SS
:
J1, J2 ( IM2E1) RMBypass2E1. RM
Bypass2E1 .
J3, J4 ( IM2E1) RMBypass2E1. RM
Bypass2E1 .
J5 , .
RJ45 ( ISO/IEC 8877)
3, 6
RCV (tip, ring) Receive Data in
4, 5
XMT (tip, ring) Transmit Data out
rev.28.04.2014
. .
.
37
, E1
,
. NSG
.
NX300/3WL2
NX300/4W2
NX300/7WL4
NX300/8W4
NX300/3WLMH2
NSG800/4WL2 h/w v1
NSG900/4WL2 h/w v1
NSG800/WL h/w v1
NSG800/maxI16
NSG800/16A h/w v.1.2
NSG900/16A h/w v.1
(16- .)
NSG800/16A h/w v1.2
NSG900/16A h/w v.1
(8- .)
E1
IME1 (IME1SS)
IM2E1
IMCE1
NX300_3wl.bin
NX300_4w.bin
NX300_7wl.bin
NX300_8w.bin
NX300_3wl.bin
NX300_3wl_1e.bin
NX300_4w_1e.bin
NX300_7wl_1e.bin
NX300_8w_1e.bin
NX300_3wl_1e.bin
NX300_3wl_2e.bin
NX300_4w_2e.bin
NX300_3wl_2e.bin
NX300_3wl_ce1.bin
NSG800_4wl.bin
NSG800_4wl_1e.bin
NSG800_4wl_2e.bin
NSG800_4wl_1ce.bin
NSG800_wl.bin
NSG800_wl_1e.bin
NSG800_MaxI16.bin NSG800_MaxI16_1e.bin
NSG800_16am.bin
NSG800_16am_1e.bin
NSG800_16am_2e.bin NSG800_16am_1ce.bin
NSG800_8am.bin
NSG800_8am_1e.bin
NSG800_8am_2e.bin
NSG800_8am_1ce.bin
. TFTP, ,
, E1, .
IMxE1 ,
. RJ45 .
IM2E1 NSG520 .
L2
NSG520 E1
IF:1 L1
IF:2
unframed. ,
DOWN. :
(LOS, loss of signal)
NSG520
FAS/NFAS (LOF, loss of frame)
CAS MFAS (CAS
LOMF, loss of CAS multiframe)
CRC4 (CRC4 LOMF, loss of CRC4 multiframe).
IMxE1x .
IF:1
IF:0
DCD,
L0
E1 , , L1
. :
DOWN (. )
IM2E1
TESTING,
(remote loopback)
, drop-and-insert E1
( IDLE) .
NSG Reset W S PO:A
E1 , E1.
W S IF:<>, .
NSG Linux .
E12 NSG520 hardware v1,
hardware v2, firmware v1.
RMBypass2E1 NSG520 hardware v1 v2,
IM2E1 firmware v11.
hardware firmware Display Version (D V).
RMBypass2E1 4.6.
IMCE1S NSG.
NSG800/WL h/w ver.2.0 NSG800/16A h/w ver.1.1 IMxE1.
rev.28.04.2014
38
4.3. E1 . 2004 .
: IME1S, IM2E1S, IMCE1S
NSG520 hardware version 4 ( )
:
E1
E1.
. 1999 .,
RJ45.
IME1S
(.. ).
IM2E1S IME1
drop-and-insert. RMBypass2E1
E1 .
IMCE1S , 31 (..
31 ) .
NSG520 h/w ver.4 E1.
IM2E1S, RMBypass2E1.
()
(-) .
E12* unframed.
, 2004 , 1:
IME1S, IM2E1S, IMCE1S
.2004 .
NSG520, NSG800/WL
NX300, NSG800/maxI
NSG800 NSG900 19" 1U 2
rev.28.04.2014
39
():
WAN :
E1
EXT
64000 2048000 / ( ).
( framed E1) 2048 / (
unframed E12).
IME1S
IM2E1S
IMCE1S
NSG520
WAN ( )
, ,
IF:0 PO:1
IF:0 PO:1
IF:0 PO:4
3914227
35
8014227
65
3914227
35
IF:0 PO:2
PO:1
PO:2
PO:3
PO:4
PO:1
PO:2
IF:0 PO:131
IF:0
IF:1
IF:0
IF:1
IF:0
IF:1
IF:0 PO:232
IF:0 PO:434
IF:0 PO:232
IF:1 PO:1
IF:2 PO:2
NSG
E1. NSG Linux (L) E1
, .. IMCE1S .
NSG900/8WL ( L2).
. NSG900/4WL.
IMCE1S NSG.
IM2E1S .
NSG .
NSG800/WL h/w v.2.1
NSG800/WL h/w v.2.2
NSG900/2WL
NSG800/4WL h/w v.2
NSG900/4WL h/w v.2
NSG800/16A h/w v.2
NSG900/16A h/w v.2
(16- .)
NSG800/16A h/w v.2
NSG900/16A h/w v.2
(8- .)
E1
IME1S
IM2E1S
IMCE1S
NSG800_wl.bin
NSG800_wl_1e.bin
NSG800_wl_1e.bin
NSG800_2wl.bin
NSG800_2wl_1e.bin
NSG800_2wl_2e.bin
NSG800_2wl_1ce.bin
NSG800_4wl.bin
NSG800_4wl_1e.bin
NSG800_4wl_2e.bin
NSG800_4wl_1ce.bin
NSG800_16am.bin
NSG800_16am_1e.bin
NSG800_16am_2e.bin NSG800_16am_1ce.bin
NSG800_8am.bin
NSG800_8am_1e.bin
NSG800_8am_2e.bin
rev.28.04.2014
NSG800_8am_1ce.bin
40
NSG 8.2.1
. , E1
,
.
. TFTP, ,
, E1, .
NSG Linux ,
E1 .
RJ45
IMxE1S ( )
RJ45
J5
J4
J1
J5
RJ45
J2
RJ45
J3
J5
:
J1, J2 ( IM2E1S) RMBypass2E1. RM
Bypass2E1 .
J3, J4 ( IM2E1S) RMBypass2E1. RM
Bypass2E1 .
J5 , .
rev.28.04.2014
41
XMT tip
XMT ring
XMT shield
RCV tip
RCV ring
RCV shield
Transmit Data out
.
.
.
Receive Data in
IMxE1S ,
. RJ45 .
DCD, E1 , ,
. :
DOWN :
(LOS, loss of signal)
FAS/NFAS (LOF, loss of frame)
CAS MFAS (CAS
LOMF, loss of CAS multiframe)
CRC4 (CRC4 LOMF, loss of CRC4 multiframe).
TESTING, (remote loopback)
, drop-and-insert E1
( Idle) .
NSG Reset W S PO:A
E1 , E1.
W S IF:<>, .
NSG Linux .
RMBypass2E1 4.6.
rev.28.04.2014
42
4.4. IM703/64xxx
( )
IM703/64CND
IM703/64CD
RJ45
RJ45
RJ45
3, 6
RCV (tip, ring)
4, 5
XMT (tip, ring)
1, 2
RCVT (tip, ring)
7, 8
XMTT (tip, ring)
Receive Data in
Transmit Data out
Receive Timing in
Transmit Timing in
rev.28.04.2014
43
E0
E0 .
(codirectional) ,
.
E0 .
Data
IF:G703_1
MODE:LOCAL
Timing
IF:G703_1
MODE:LOOP
Timing
Data
.
,
. PDH
, , .
NSG MODE:LOOP.
(contradirectional) , ,
,
(controlling equipment) (controlled subordinate equipment)
. E0 .
Data
E0
Controlling
Equipment
Timing
Timing
E0
Controlled
Equipment
Data
IM703/64CND
. , PDH
.
:
.
.
rev.28.04.2014
44
balanced
IM703 ( )
NSG 1, DBH26f ;
CAB703
NSG 1, NSG5xx DB25f
384224
15
IM7032
NSG 2,
RJ45
NSG 2
386027
25
:
/ : 1500
: .
, ,
.
, , LOOP.
:
( )
703
IM703
IM7032
LOCAL LOOP ( )
2048000 / ( )
RJ45
J1
:
LOCAL 1 2 (
)
LOOP 2 3
:
( )
,
.
RJ45
3, 6
RCV (tip, ring) Receive Data in
4, 5
XMT (tip, ring) Transmit Data out
DBH26f
10, 11
RCV (tip, ring) Receive Data in
12, 13
XMT (tip, ring) Transmit Data out
G.703
DBH26f
10
11
12
13
RJ45
3
6
4
5
.
.
rev.28.04.2014
45
4.6. RMBypass2E1
: E1
NSG
:
: NSG520, IM2E1
:
8
0,05
3
100 .
1 A 30 V DC 200 .
: 373323
:
5
( )
:
J3
J4
:
:
RMBypass2E1
drop-and-insert.
E1
NSG.
RMBypass2E1
E1 ,
NSG
J1, J2
.
RMBypass2E1
.
.
3. (. ).
4. RMBypass2E1: J11 J14 J21 J24,
RJ45 E1.
8 2 J3, J4,
NSG520 IM2E1. ,
.
,
.
J3
J4
.
5.
, RMBypass2E1
,
/ .
2 E1
1 E1
LED
rev.28.04.2014
J24
J21
J14
J11
1.
2.
46
5. Ethernet
5.1. Ethernet 10/100BaseT
: IEEE 802.3
:
: 10 /,
10 /,
100 /,
/ : 1500
:
:
- Fast Ethernet .
, 00.09.56.xx.xx.xx
NSG:
TP
10000000 100000000 / ( )
HALF, FULL, AUTO
:
PWR .
LNK Ethernet. / .
100
100 /.
Fdx
Full Duplex. Ethernet.
1
RJ45
1
TX+
Transmit Data +
2
TX
Transmit Data
3
RX+
Receive Data +
6
RX
Receive Data
8
100 Pwr
Fdx Lnk
1 8
:
RJ45 ,
( NSG).
, , ,
( xDSL, , )
( NSG).
"Ethernet RJ45 crossover"
()
,
NSG
..
TxD+ 1
3 RxD+
TxD 2
6 RxD
RxD+ 3
1 TxD+
RxD 6
2 TxD
rev.28.04.2014
47
15
/ : 1500
:
:
TP
10000000 / ( )
HALF FULL (. )
- 00.09.56.xx.xx.xx
:
Rx, Tx
, ,
.
FDX/Cln , Full Duplex ,
Half Duplex
Ethernet.
TP
( NX300 IMET10, IMET10F.)
,
Ethernet.
TP Rx
FDX/Cln Tx 1
RJ45
1
TX+
Transmit Data +
2
TX
Transmit Data
3
RX+
Receive Data +
6
RX
Receive Data
1 8
IMET10, IMET10F
:
RJ45 ,
( NSG).
, , ,
( xDSL, , )
( NSG).
"Ethernet RJ45 crossover" ()
,
NSG
..
TxD+ 1
3 RxD+
TxD 2
6 RxD
RxD+ 3
1 TxD+
RxD 6
2 TxD
rev.28.04.2014
48
rev.28.04.2014
49
6.
6.1. IMGPRS h/w ver.1, 2
IMGPRS
GSM/GPRS CSD (Circuit Switched Data) GPRS (General Packet Radio Service).
:
CSD "-" () GSM
CSD "-" GSM
CSD "-" ,
CSD "-" NSG
GPRS "-" NSG
:
hardware version 1 Wavecom Q2406B Q24Plus
hardware version 2 FLYFOT M260
: ETSI GSM Phase 2+, 900/1800
GPRS 10 ( 4 , 2, 5)
:
GSM 4 (2 @ 900 ) 1 (1 @ 1800 )
: V.21, V.22, V.22bis, V.23, V.26ter, V.32, V.34, V.110
: MNP2, V.42bis, V.42
CSD: 300 / 9600 / ( GSM )
. 14400 / ( ISDN GSM, )
:
: NSG 2, SMAf ,
SIM-
: 377623
: 20
: , , 2,5
: NSG800 NSG900 19" 1U 2
NSG900/8WL 2,
NSG700/4AU h/w ver.5 1
NSG7xx
NSG5xx, NX300/xx2, NSG800/WL, NSG900/2WL 1 .
NSG 2
NX300/7WL4, NX300/8W4 1 . 37
(.: NX300/xxx 3
1 )
: SIM-
( )
J1
DTR ( ) NSG
12 ( DTR
) ( / )
DTR Low Functionality
23
( AT+CFUN=0, AT+CPOF)
WAVECOM
: ,
GSM.
:
NSG
-
RS232 . ,
IMGPRS,
:
(NSG Linux 2.0/1.0) rs-232 / im-v24 ( V24)
8N1
300, 600, 1200, 2400, 4800, 9600, 19200, 38400, 57600, 115200 /.
Wavecom Q24Plus
AT+IPR=xxx;&W
J1 1 2 3
rev.28.04.2014
50
GPRS/EDGE/HSDPA
CSD
SMS-
ppp
ppp
sms-handler
raw-access
ppp
ppp, slip, pad, telnet, reverse-telnet
sms-handler
reverse-telnet
ASYNC_PPP
ASYNC_PPP, SLIP, PAD, ASYNC
ASYNC, PAD
-, ETSI GSM 07.05, ETSI GSM 07.07 ITUT
V.25ter. IMGPRS h/w ver.1 CSD GPRS
NSG:
GSM/GPRS, EDGE 3G NSG.
:
GPRS/EDGE/HSDPA ( .. ,
IP-over-PPP, , ..)
.
GSM CSD ,
, . (..
"".)
J1 ,
( ). / DTR
.
DTR
.
6.40 ( 6.41 ).
ATI3 .
NSG .
(
).
( -)
. .
,
(1025 .) .
DTR ( Wavecom Q24Plus)
. J1
, .
V.110
.
IMGPRS h/w ver.1 Wavecom 6.41 ( I 2006 .
) SIM-, ,
.
2030 . SIM , NSG
( 6.55 ). .
6.55
rev.28.04.2014
51
IMGPRS
GSM/GPRS CSD (Circuit Switched
Data) GPRS (General Packet Radio Service).
:
CSD "-" () GSM
CSD "-" GSM
CSD "-" ,
CSD "-" NSG
GPRS "-" NSG
2 SIM-
( NSG Linux 1.0 build 3 )
: ETSI GSM Phase 2+, 900/1800
GPRS 10 ( 4 , 2, 5)
:
GSM 4 (2 @ 900 ) 1 (1 @ 1800 )
: V.21, V.22, V.22bis, V.23, V.26ter, V.32, V.34
: MNP2, V.42bis, V.42
CSD: 300 / 9600 / ( GSM )
. 14400 / ( ISDN GSM, )
:
: NSG 2, SMAf , 2
SIM-
: 4011623
: 25
: , , 2,5
: NSG800 NSG900 19" 1U 2
NSG900/8WL 3 4 (
3 4 )
NSG800/WL, NSG900/2WL 1 .
NSG 2
( )
NSG700/4AU h/w ver.5 1
NSG7xx
NSG500, NSG500/C 1
NX300/3WL2, NX300/4WL2 1 . 0, 1, 2
NX300/7WLx, NX300/7WLx 1 . 4, 5
: SIM-()
J1
DTR ( ) NSG
DTR
( / )
J2 SIM-
SIM- MAIN
SIM- ,
chat-script virtual-template
:
NSG -
RS232 . ,
IMGPRS, :
(NSG Linux 2.0/1.0) gsm-2sim / im-v24
( V24)
300, 600, 1200, 2400, 4800, 9600, 19200, 38400, 57600, 115200 /.
AT+IPR=xxxx;&W. 115200 /.
8N1
rev.28.04.2014
J1
J2
FLYFOT
M260
52
GPRS/EDGE/HSDPA
CSD
SMS-
ppp
ppp
sms-handler
raw-access
ppp
ppp, slip, pad, telnet, reverse-telnet
sms-handler
reverse-telnet
ASYNC_PPP
ASYNC_PPP, SLIP, PAD, ASYNC
ASYNC, PAD
-, ETSI GSM 07.05, ETSI GSM 07.07 ITUT
V.25ter. IMGPRS h/w ver.3 CSD GPRS
NSG:
GSM/GPRS, EDGE 3G NSG.
: .
:
GPRS/EDGE/HSDPA ( .. ,
IP-over-PPP, , ..)
.
GSM CSD ,
, . (..
"".)
( -)
. .
,
(1025 .) .
DTR .
J1 ,
.
V.110 .
PPP SMS- .
DCD
ppp options local PO:n CD:NO ( ).
rev.28.04.2014
53
IMEDGE
GSM CSD (Circuit Switched Data),
GPRS (General Packet Radio Service) EDGE (Enhanced Data rates for
Global Eolution). :
CSD "-" GSM
CSD "-" GSM
CSD "-" ,
CSD "-" NSG
GPRS "-" NSG
EDGE "-" NSG
: h/w ver.1 1 SIM- ( );
h/w ver.2 2 SIM-
(
NSG Linux 1.0 build 3 )
: ETSI GSM Phase 2+, 900/1800/1900
GPRS/EGPRS Multi-slot Class 8, 10, 12 ( 4,
5), 236,8 /
:
GSM 4 (2 @ 900 ) 1 (1 @ 1800 )
EGSM E2 (0,5 @ 900 , 0,4 @ 1800/1900 )
: V.21, V.22, V.22bis, V.23, V.26ter, V.32, V.34, V.110
: MNP2, V.42bis, V.42
CSD: 300 / 9600 / ( GSM )
. 14400 / ( ISDN GSM, )
:
: NSG 2, SMAf ,
SIM- (1 2 )
: NSG800 NSG900 19" 1U 2
NSG900/8WL 3 4 ( 3 4 )
NSG800/WL, NSG900/2WL 1 . NSG 2
NSG700/4AU h/w ver.5 1
NSG7xx
NSG500, NSG500/C 1
NX300/3WL2, NX300/4WL2 1 . 0, 1, 2
NX300/7WLx, NX300/7WLx 1 . 4, 5
: 4012023
: 25
: , , 2,5
: SIM-()
J1
DTR ( ) NSG
DTR
( / )
J2 SIM-
( IMGPRS h/w ver.3, UIM3G)
SIM- MAIN
SIM- ,
chat-script virtual-template
:
NSG
- RS232 . ,
IMEDGE, :
IMEDGE v1 (NSG Linux 2.0/1.0) rs-232 / im-v24 ( V24)
IMEDGE v2 (NSG Linux 2.0/1.0) gsm-2sim / im-v24 ( V24)
8N1
rev.28.04.2014
54
GPRS/EDGE/HSDPA
CSD
SMS-
ppp
ppp
sms-handler
raw-access
ppp
ppp, slip, pad, telnet, reverse-telnet
sms-handler
reverse-telnet
ASYNC_PPP
ASYNC_PPP, SLIP, PAD, ASYNC
ASYNC, PAD
-, ETSI GSM 07.05, ETSI GSM 07.07 ITUT
V.25ter. IMEDGE
NSG:
GSM/GPRS, EDGE 3G NSG.
: .
:
GPRS/EDGE/HSDPA ( .. ,
IP-over-PPP, , ..)
.
GSM CSD ,
, . (..
"".)
( -)
. .
,
(2035 .) .
IMGPRS,
IMEDGE h/w ver.1
GPRS-
( )
IMEDGE h/w ver.2
,
( )
.
CSD
DCD.
ppp options local PO:n
CD:NO (
).
J1
J2
J1
SIM600
rev.28.04.2014
SIM600
55
DTR
( / )
J2 SIM-
SIM- MAIN
SIM- ,
chat-script virtual-template
h/w ver.3 3a
.
NSG Linux 1.0 card sN uim-edge
uim-edge-3a, ; NSG Linux 2.0
.
SIM700D ( ):
ver.3 MP061044xxxxxxx , MP061139xxxxxx
ver.3a MP061047xxxxxxx, MP061105xxxxxxx
rev.28.04.2014
J2
J1
SIM700
56
:
) USB ( NSG700, NSG1800, NSG1000)
NSG Linux 2.0 edge.
USB ( NSG700, NSG1000)
NSG Linux 2.0 uim-edge uim-edge-3a, .
) , NSG,
- .
, UIMEDGE h/w ver.3,
.
(NSG Linux 1.0) im-v24 ( V24)
8N1
300, 600, 1200, 2400, 4800, 9600, 19200, 38400, 57600, 115200, 230400 /. (230400
NSG5xx.)
AT+IPR=xxxx;&W. 115200 /.
AT&F 460800 /,
, .
(NSG Linux) ( )
GPRS/EDGE/HSDPA
CSD
SMS-
ppp
ppp
sms-handler
raw-access
ppp
ppp, slip, pad, telnet, reverse-telnet
sms-handler
reverse-telnet
ASYNC_PPP
ASYNC_PPP, SLIP, PAD, ASYNC
ASYNC, PAD
-, ETSI GSM 07.05, ETSI GSM 07.07 ITUT
V.25ter. UIM3G
NSG:
GSM/GPRS, EDGE 3G NSG.
: .
:
GPRS/EDGE/HSDPA ( .. ,
IP-over-PPP, , ..)
.
GSM CSD ,
, . (..
"".)
( -)
. .
,
(2035 .) .
USB (, SIM-)
DTR, RTS ,
. s2 NSG
700/4AU h/w ver.5 . serialover-USB, , .
rev.28.04.2014
57
( / )
J2 SIM-
SIM- MAIN
SIM- ,
chat-script virtual-template
rev.28.04.2014
58
:
) USB ( NSG700, NSG1800 NSG1000)
NSG Linux 2.0 3g; NSG Linux 1.0 uim-3g.
) , NSG, - . , UIM3G, .
(NSG Linux 1.0) im-v24 ( V24)
8N1
300, 600, 1200, 2400, 4800, 9600, 19200, 38400, 57600, 115200, 230400 /. (230400
NSG5xx.)
AT+IPR=xxxx;&W. 115200 /.
(NSG Linux) ( )
GPRS/EDGE/HSDPA
CSD
SMS-
ppp
ppp
sms-handler
raw-access
ppp
ppp, slip, pad, telnet, reverse-telnet
sms-handler
reverse-telnet
ASYNC_PPP
ASYNC_PPP, SLIP, PAD, ASYNC
ASYNC, PAD
-, ETSI GSM 07.05, ETSI GSM 07.07 ITUT
V.25ter. UIM3G
NSG:
GSM/GPRS, EDGE 3G NSG.
: .
:
GPRS/EDGE/HSDPA ( .. ,
IP-over-PPP, , ..)
.
GSM CSD ,
, . (..
"".)
( -)
. .
,
(2035 .) .
DTR .
J1 ,
.
USB (, SIM-)
DTR, RTS ,
. s2 NSG
700/4AU h/w ver.5 . serialover-USB, , .
rev.28.04.2014
59
CDMA 1x EV-DO
CDMA 1x EV-DO Rev.0.
CDMA-:
UIMCDMA h/w ver.2
CMOTech CNE510 CNE602
UIMEVDO h/w ver.2
CMOTech CNE550, 1x EV-DO
: CDMA 1x MC RTT (IS2000)
CDMA 1xEV-DO (IS856) UIMEVDO
450 ( 462,5467,475 ,
452,5457,475 )
. 0,20,3
CDMA: TIA/EIA IS98D, IS707A Data, IS127
/ : CDMA EV-DO (-) 2,4 /
CDMA EV-DO (-), CDMA 1x 153 /
:
USB ()
: NSG 2, SMAf ,
RUIM
: NSG800 NSG900 19" , NSG1800, NSG700 2
NSG500, NSG500/C, NSG520, NX300, NSG800/WL, NSG900/2WL 1 .
NSG 2
NSG510, NSG510/C IMCDMA h/w ver.1, 0
, :
NSG5xx 115,2 /
230,4 /
USB .
: 388020
: 20
: , , 2,5
( )
: RUIM
J1
DTR ( ) NSG
( DTR
)
( / )
! USB J1
.
:
) USB ( NSG700, NSG1000)
NSG Linux UIMCDMA, UIM
EVDO card sN uim-cdma.
) , NSG,
-
RS232 . ,
J1
UIMCDMA UIMEVDO,
.
(NSG Linux 1.0) im-v24 ( V24)
:
300, 600, 1200, 2400, 4800, 9600, 19200, 38400, 57600, 115200
230400 /. (230400 NSG5xx.)
CNE510 CNE602
IMCDMA
UIMCDMA
AT+IPR=xxxx;&W. 115200 /.
CNE550
,
UIMEVDO
NSG.
8N1
ppp ( reverse-telnet
NSG Linux 1.0); ASYNC_PPP ASYNC, .
rev.28.04.2014
60
-
IS707, Qualcomm CMOTech. ,
IMCDMA, NSG:
CDMA EV-DO NSG.
:
DCD, ..
CDMA- ;
.
USB (NSG700, NSG1000) .
:
. -.
. (3035 .) .
USB .
.
rev.28.04.2014
61
CDMA 1x
CDMA. CDMA-:
IMCDMA h/w ver. 1 AnyDATA.NET DTG450
IMCDMA h/w ver. 3 AnyDATA.NET DTU450X
: CDMA 1x MC RTT (IS2000)
450 (
462,5 467,475 , 452,5457,475 )
( )
0,20,3
CDMA: TIA/EIA IS98D, IS707A Data, IS127
/ : 153 /
:
: NSG 2, SMAf
, RUIM
IMCDMA h/w ver.1
IMCDMA h/w ver.3
:
AnyDATA
NSG900/8WL
2
3 4*
NSG500, NSG500/C,
1 .
1 .
Model name: DTG450
NSG520, NX300
2
2
NSG510, NSG510/C
0
* 3 4
J1
hardware version 1
J1
rev.28.04.2014
AnyDATA
:
NSG
-
RS232 . ,
IMCDMA,
:
(NSG Linux 2.0/1.0) rs-232 / im-v24 ( V24)
8N1
300, 600, 1200, 2400, 4800, 9600, 19200, 38400, 57600, 115200, 230400
/. (230400 NSG5xx.)
AT+IPR=xxxx;&W. 115200 /.
ppp ( reverse-telnet
NSG Linux 1.0); ASYNC_PPP
ASYNC, .
- IS707, Qualcomm
AnyDATA.NET. , IM
CDMA, NSG:
CDMA EV-DO NSG.
( IMCDMA h/w ver.1)
hardware version 3
:
. -.
. (3035 .) .
62
EV-DO
CDMA EV-DO Rev.0, CDMA 1x.
CDMA- DTM300A. .
NSG.
: CDMA 1x MC RTT (IS2000)
CDMA 1xEV-DO (IS856)
450 ( 462,5467,475 ,
452,5457,475 )
. 0,20,3
CDMA: TIA/EIA IS98D, IS707A Data, IS127
/ : CDMA EV-DO (-) 2,4 /
CDMA EV-DO (-), CDMA 1x 153 /
:
UMEVDO h/w ver.4 ( ) USB
UIMEVDO h/w ver.6 USB ()
: NSG 2, SMAf ,
RUIM
: NSG800 NSG900 19" , NSG700/40AR UIMEVDO h/w ver.6,
2
NSG1800, NSG700
NSG800/WL, NSG900/2WL UIMEVDO h/w ver.6, 1 .
NSG 2
NSG500, NSG500/C, NX300 UIMEVDO h/w ver.6, 1 .
NSG 2
, :
NSG5xx 115,2 /
230,4 /
USB .
: 3911720
: 25
( )
: , , 2,5
: RUIM
J1
DTR ( ) NSG
( DTR
)
( / )
AnyDATA
rev.28.04.2014
J1
:
) USB ( NSG700, NSG1000)
NSG Linux 1.0
card sN uim-3g ().
) , NSG,
UIMEVDO h/w ver.6 -
RS232 .
.
im-v24 ( V24)
300, 600, 1200, 2400, 4800, 9600, 19200, 38400, 57600, 115200
230400 /. (230400 NSG5xx.)
IMCDMA
AT+IPR=xxxx;&W. 115200 /.
,
NSG.
8N1
ppp ( reverse-telnet
NSG Linux 1.0);
ASYNC_PPP ASYNC, .
- IS707, Qualcomm
63
AnyDATA.NET. , IMCDMA,
NSG:
CDMA EV-DO NSG.
:
. -.
. (3035 .) .
USB DTR
, .
s2 NSG700/4AU h/w ver.5 .
serial-over-USB,
, .
rev.28.04.2014
64
7. IMC1
: NSG 1.
: IM1/9K6, IM1/256, IM1/2048
: 2723287
:
: 2
:
IM1/9K6
6009600 /
IM1/256
48256 /
IM1/2048 2562048 /
:
:
: NSG 1, DBH26f
: NX300/xx, NSG800/xx, NSG900/xx NSG 1
:
404229
:
50
/ : 1500
:
:
C1_9K6, C1_256 C1_2048, ( C, K )
FM0
IF:C1_9K6: 600, 1200, 1800, 2400, 4800, 9600 /
IF:C1_256: 48000, 64000, 80000, 128000, 192000, 256000 /
IF:C1_2048: 256000 2048000 / 64000 / ( )
, , .
( )
DBH26f
DBH26f
10, 11
RCV (tip, ring) Receive Data in
12, 13
XMT (tip, ring) Transmit Data out
7, 16
GND
Signal Ground
:
.
RCV XMT . .
rev.28.04.2014
65
8.
8.1. - IMDIO, IMDIO2
: / ()
/ ()
: IMDIO/8i4o, IMDIO2/8i4o 8 , 4
:
: 8
: 7 B
: 5
: 15
: 10
: 4
: 60
: 250
: 5
( )
: 10
IMDIO ( )
NSG 1,
DBH26f
NSG 1 DBH26f
IMDIO2
NSG 2,
DBH26f
NSG700 1;
NSG 2
399421
35
397115
20
: 19200 /
/ : 1500
:
:
DBH26f
/
IMDIO/8i4o
( )
IMDIO
IMDIO2
DBH26f
DBH26f
. 100 mA
rev.28.04.2014
66
NSG Linux
im-dio
NSG:
SERVICE
DIO
:
SV:ssss (s=0|1)
TR:bbbbbbbb , TRAP ( b=0|1)
OA:ssss ( s=0|1)
On:s n (s=0|1)
. , SV, ,
W S PO:n. W S PO:A
Reset .
:
SNMP.
MIB IMDIO SNMP nsg-gs.mib nsg-ss.mib.
.
220.
RH
+
(IN)
5V
I=10 mA
(OUT)
Imax=250 mA
~ 60 V
" "
330
+
(IN)
I=510 mA
(OUT)
5V
+
TTL-
(OUT)
"Reset"
rev.28.04.2014
8.2.
1/2
67
: NSG,
- IMDIO IMDIO2.
: , .
: 1
: 240
: 2
: < 8
: 1020
: 954738
: 0,2
:
6
:
NSGxxx
IMDIO(2)
RJ12
1/2
~220B
1/2
1
2
3
5
4
+5
5
6
RJ11
( 2, 3)
:
1 IMDIO/8i4o
DBH26m
RJ12
RJ11
21
4
3
7, 9 16
3
2
22
8
2 IMDIO/8i4o
DBH26m
RJ12
RJ11
10
4
3
7, 9 16
3
2
11
8
3 IMDIO/8i4o
DBH26m
RJ12
RJ11
19
4
3
7, 9 16
3
2
20
8
4 IMDIO/8i4o
DBH26m
RJ12
RJ11
1
4
3
7, 9 16
3
2
2
8
rev.28.04.2014
68
A232
: NSG 1Wire .
:
: NSG 2, 2 RJ11
:
NSG800, NSG900 ( NSG900/maxU)
IM1W
NSG700 , s2
NSG700/4AU h/w ver.5
RJ12
RJ12
NSG1000
: 593615
: 15 .
:
: 10 , . 125
:
IM1W:
card sN im1w card sN imv24
port sN
encapsulation one-wire
one-wire
IM1W
12
NSG
~220B
(
>100 )
NSG ( Reset)
.
1Wire NSG OEM- . :
1Wire .
.
rev.28.04.2014
69
9. DoC FLEX
: NSG800, NSG900
NSG Linux.
: . .
: NSG800/WL, NSG800/4WL, NSG800/16A,
NSG900/2WL, NSG900/4WL, NSG900/16A
DoC
32512
697813
35
:
:
FLEX
128
377613
15
DoC FLEX
1.
2.
3.
4.
5.
6.
7.
8.
.
.
(. ).
, ,
Fast Ethernet .
, "DOC" "FLEX" (
).
.
, .
.
.
:
NSG Linux ver.1.0 NSG800 4 ,
NSG Linux ver.1.0 NSG900
8 .
NSG800/maxU, NSG900/8WL Disc-on-Chip
, .
DoC NSG800,
( , ).
DoC (Disk-on-Chip) .
( ..) FLEX (FLash
EXtension).
( )
DOC
FLEX
rev.28.04.2014
70
.
, , ,
NSG
.
DTE/DCE
IMV352
IM485 IMV352
IMV24
(async)
IM530
(sync)
IMV35
IMV24A
IMX21 IMX212
IM4852
1
2
NPS7e/3W
0, 1, 2
NPS7e/3WL
Eth
0, 1, 2
NPS7e/7WL
Eth, 4RS232
0, 1, 2
NPS7e/14W
8RS232
A0, 1, 2; B0, 1, 2
NSG500
Eth, RS-232
0, 1
NSG500/C
RS232
0, 1
NSG510
Eth, RS-232
1
11
0
1
NSG510/C
RS232
1
1
0
NSG504/Voice
IDSL, FXS/FXO, Eth, RS232
1
NSG504/Voice/C
IDSL, FXS/FXO, RS232
1
NSG520
2E1, Eth, RS232
0
NX300/3WL
Eth, Con
1, 2, 3
NX300/3WL2
Eth, Con
1, 2, 3?
NX300/3WLMH2
Eth, Con
1, 3
NX300/4W
Con
0, 1, 2, 3
NX300/4W2
Con
0, 1, 2, 3?
NX300/7WL
Eth, Con
17
NX300/7WL2
Eth, Con
1, 2, 3
4, 5, 6, 7
NX300/7WL4
Eth, Con
17
NX300/8W
Con
07
NX300/8W2
Con
0, 1, 2, 3
4, 5, 6, 7
NX300/8W4
Con
0 7
NX300/8A
Eth, Con, 8RS232
1, 2
NSG800/WL h/w v.1, 2.0, 2.1, 2.3, 2.4
Fast Eth, Con
1
NSG800/WL h/w v.2.2
Fast Eth, Con
1, 2
NSG800/4WL h/w v.1
Fast Eth, Con
1, 2, 3, 4
NSG800/4WL2 h/w v.1
Fast Eth, Con
12, 22, 32, 42
NSG800/4WL h/w v.2
NSG800/16A h/w v.1.1, 1.2, 2.1
Fast Eth, Con, 16(8)RS232
1, 2
NSG900/2WL
Fast Eth, Con
1, 2
NSG900/4WL h/w v.1
Fast Eth, Con
1, 2, 3, 4
NSG900/4WL2 h/w v.1
Fast Eth, Con
1, 2, 3, 4
NSG900/4WL h/w v.2
NSG900/8WL (
Fast Eth (TP+MMF/SMF)
14
14
8- )
Con
A1A4
NSG900/16A h/w v.1, 2
Fast Eth, Con, 16(8)RS232
1, 2
.
( 2003 .) NX300, WAN 3 1, NSG5xx
DB25f.
NSG800 2 IMET10F / IMV352
2048 / .
rev.28.04.2014
71
NPS7e/3W
NPS7e/3WL
NPS7e/7WL
NPS7e/14W
NSG500
NSG500/C
NSG510
NSG510/C
NSG504/Voice
NSG504/Voice/C
NSG520
NX300/3WL
NX300/3WL2
NX300/3WLMH2
NX300/4W
NX300/4W2
NX300/7WL
NX300/7WL2
NX300/7WL4
NX300/8W
NX300/8W2
NX300/8W4
NX300/8A
NSG800/WL
h/w v.1, 2.0, 2.1, 2.3, 2.4
NSG800/WL h/w v.2.2
NSG800/4WL h/w v.1
NSG800/4WL2 h/w v.1
NSG800/4WL h/w v.2
NSG800/16A
h/w v.1.1, 1.2, 2.1
NSG900/2WL
NSG900/4WL h/w v.1
NSG900/4WL2 h/w v.1
NSG900/4WL h/w v.2
NSG900/8WL (
8- )
NSG900/16A h/w v.1, 2
IMIDSL
IMSRM2
IMSHDSL
IMSDSL
IMMDSL/xxx
IMSHDSL/bis
IM2SHDSL/bis
IMSRM
( 1)
IMV92
IMV34
xDSL, , 1 Ethernet
IMSDSL v.2
IM1 IMET10
( 1) IMET10F
Eth-over-SDSL
0, 1, 2
0, 1, 2
0, 1, 2
A0, 1, 2
B0, 1, 2
11
11
0, 1
0, 1
0
0
1
1
0
1, 2, 3
1, 2, 3
1, 22, 31
1, 3
04
04
0, 1, 2, 3
0, 1, 2, 3
0, 12, 22, 31
17
1, 2, 3
07
0, 1, 2, 3
0
17
1, 2, 3
4, 52, 62, 7
1,2
3 , 4, 52, 62, 7
07
0, 1, 2, 3
4, 52, 62, 7
1,2
3 , 4, 52, 62, 7
04
1, 2
1,2
1
1
3
*
1, 2, 3, 4
1, 23
1, 2
1, 2
1, 2
1, 2, 3, 4
3, 4
1, 2, 3, 43
15, 25,
35,44,5
1, 2
1, 2
1, 2
1, 2
1, 2
1, 2
1, 2
*
1, 2, 3, 4
1, 23
1, 2, 3, 4
3, 4
1, 2, 3, 43
1, 2, 3, 43
3, 4
1, 2
1, 2
1, 2, 3, 4
1, 2, 3, 4
14
A1A4
14
1, 2
1, 2, 3, 43
*
1, 2
.
( 2003 .) NX300, WAN 3 1, NSG5xx
DB25f.
2
IMSHDSL , .
3
IMET10, IMET10F, IMSDSL Ethernet-over-SDSL .
4
IMET10(F) NX300/3WL, NX300/7WL,
. IMET10F v8.2.2 ; .
5
NSG800 2 IMET10F / IMV352
2048 / .
* 1 ( ).
1
rev.28.04.2014
72
PDH
NX300/3WL2
NX300/3WLMH2
NX300/4W2
NX300/7WL4
NX300/8W4
NSG800/maxI
NSG800/WL h/w ver.1
h/w ver.2.0
h/w ver.2.1, 2.3, 2.4
h/w ver.2.2
NSG800/4WL2 h/w ver.1
NSG800/4WL h/w ver.2
NSG800/16A
h/w ver.1.1
h/w ver.1.2
h/w ver.2
NSG900/2WL
NSG900/4WL2 h/w ver.1
NSG900/4WL h/w ver.2
Fractional E1
2E1 drop-and-insert
Channelized E1
IME1 IME1S IME1SS IM2E11 IM2E1S1 IMCE1 IMCE1S
22
1+22
20
1+20
20
2
2
2
1+2
22
22
X1
1
14
1, 23
NSG900/16A
h/w ver.1
h/w ver.2
1+2
3 3, 4
32
3+4
3
3,4
3+4
1 3, 2
1+2
3
1
13, 2
1, 23
1+2
1+2
3 3, 4
3+4
33, 4
33, 4
A33,5, A45
NSG900/8WL
24
2
1 3, 2
3
3+4
3+4
A3+A45
1+2
13, 2
IM703 IM7032 IM703/64
0, 1, 2
NPS7e/14W
A0,1,2
B0,1,2
NSG500, NSG500/C
0, 1
0, 1
NSG510, NSG510/C
1
0
0
NSG520
0
0
NX300/3WL
1, 2, 3
NX300/3WL2
1, 2, 3?
1, 2, 3?
NX300/4W
0, 1, 2, 3
NX300/4W2
0, 1, 2, 3? 0, 1, 2, 3?
NX300/7WL
17
NX300/7WL2
1, 2, 3
4, 5, 6, 7
4, 5, 6, 7
?
NX300/7WL4
17
3 , 4, 5, 6, 7
NX300/8W
07
NX300/8W2
0, 1, 2, 3 4, 5, 6, 7
4, 5, 6, 7
NX300/8W4
07
3?, 4, 5, 6, 7
NX300/8A
1, 2
NSG800/WL h/w ver.1, 2.0, 2.1, 2.3, 2,4
1
1
rev.28.04.2014
3
3
A35
1
1+2
NPS7e/3W
NPS7e/3WL
NPS7e/7WL
1
2
1, 23
.
NX300/3WLMH2
IMCE1
,
2.
IM2E1, IM2E1S
.
(
).
NSG
Linux.
1 2.
.
73
2 IMxxx UIMxxx
NSG500
NSG500/C
NSG504/Voice
NSG504/Voice/C
NSG510
NSG510/C
NSG520
NX300/3WL2
NX300/3WLMH2
NX300/4W2
NX300/7WL2
NX300/7WL4
NX300/8W2
NX300/8W4
NSG800/WL
h/w v.1, 2.0, 2.1, 2.3, 2.4
NSG800/WL h/w v.2.2
NSG800/4WL2 h/w v.1
NSG800/4WL h/w v.2
NSG800/16A
h/w v.1.1, 1.2, 2.1
NSG900/2WL
NSG900/4WL2 h/w v.1
NSG900/4WL h/w v.2
NSG900/8WL
NSG900/16A h/w v.1, 2
UIMCDMA v2
IMCDMA v3 UIMEVDO v6
IMCDMA IMGPRS v1
UIMEVDO v2
IMGPRS v3
UIMEDGE
v1
IMGPRS v2
UIM3G
IMEDGE v1,2
v3, 3a
0, 1
0, 1
0, 1
1
1
0, 1
0, 1
0, 1
1
1
1
1
1
1
1
1
1
1
1
1
3
0
0
0
03
0
0
3
0
0
0
1, 2, 31
1, 2, 31
1, 2, 31
1, 2
1, 2
1, 3
1, 3
1, 3
1
1
0, 1, 2, 31
0, 1, 2, 31
0, 1, 2, 31
0, 1, 2
0, 1, 2
4, 5, 6, 7
4, 5, 6, 7
4, 5, 6, 7
4, 5
4, 5
31, 4, 5, 6, 7
17
31, 4, 5, 6, 7
4, 5
4, 5
4, 5, 6, 7
4, 5, 6, 7
4, 5, 6, 7
4, 5
4, 5
31, 4, 5, 6, 7
07
31, 4, 5, 6, 7
4, 5
4, 5
1
1, 2
1, 2
1, 2
1, 2, 3, 4
1, 2, 3, 4
1, 2, 3, 4
1, 2, 3, 4
1, 2, 3, 4
1, 2
1, 2
1, 2
1, 2
1, 2
1, 2
1, 2
1, 2
1, 2, 3, 4
1, 2, 3, 4
1, 2, 3, 4
1, 2, 3, 4
1, 2, 3, 4
1, 2, 3, 4
1, 2
1, 2, 3, 4
1, 2
1, 2, 3, 4
1, 2
3, 4
1, 2
3, 4
1, 2
.
( 2003 .) NX300, WAN 3 1, NSG5xx
DB25f.
NSG500, NX300, NSG800/WL, NSG900/2WL 1 .
: NSG5xx 115,2 /;
NX300, NSG800, NSG900, NSG700/40AR 230,4 /.
UIMCDMA v2, UIMEVDO v2.
NSG700/4AU
h/w v.2, 3, 5
h/w v.6
h/w v.6m, 6u
NSG700/8A,
NSG700/12A
NSG700/40AR
NSG709 PCI
NSG709e PCI
NSG1800
1
IMV352 (async)
IMSDSL v.2
UIM3G
IMV352
UIMCDMA
IM4852, IMV34
UIMEVDO
(sync)
v2
IMV24A, IMV92
Ethv6
IMX212
UIMEVDO
IMCDMA v1 , 3
over- HDLC
UIMEDGE
IMIDSL
v2
IMGPRS v1, 2, 3
SDSL
v3, 3a
IM703/64
IMEDGE v1 ,2
3Fast Eth
3RS232
3Fast Eth
7(11)RS232
Fast Eth
1741RS232
Fast Eth
V.24/V.35 (sync)
2Fast Eth
RS232 (async)
1+4Fast Eth
RS232 (async)
1, 2
1, 2
1, 2
1, 22
1, 2
1, 2
1
1, 2
1, 2
1, 2
1, 2
1
11
11
1
1
(, SIM-).
rev.28.04.2014
74
IM1W*
NPS7e/3W
NPS7e/3WL
NPS7e/7WL
NPS7e/14W
NSG500
NSG500/C
NSG510
NSG510/C
NSG504/Voice
NSG504/Voice/C
NSG520
NX300/3WL
NX300/3WL2
NX300/3WLMH2
NX300/4W
NX300/4W2
NX300/7WL
NX300/7WL2
NX300/7WL4
NX300/8W
NX300/8W2
NX300/8W4
NX300/8A
NSG700/4AU h/w v.2, 3, 5
NSG700/4AU h/w v.6, 6m, 6u
NSG700/8A, NSG700/12A
NSG700/40AR
NSG709 PCI, NSG709e PCI
NSG800/WL h/w v.1, 2.0, 2.1, 2.3, 2.4
NSG800/WL h/w v.2.2
NSG800/4WL h/w v.1
NSG800/4WL2 h/w v.1
NSG800/4WL h/w v.2
NSG800/16A h/w v.1.1, 1.2, 2.1
NSG900/2WL
NSG900/4WL h/w v.1
NSG900/4WL2 h/w v.1
NSG900/4WL h/w v.2
NSG900/8WL (
8- )
NSG900/16A h/w v.1, 2
IMDIO
( 1)
0, 1, 2
0, 1, 2
0, 1, 2
A0, 1, 2
B0, 1, 2
IMDIO2
0, 1
0, 1
0
0
1
1
0
11
11
1, 2, 31
1, 2, 31
1, 3
0, 1, 2, 31
0, 1, 2, 31
1
3 , 47
2, 31
31, 47
2, 31
4, 5, 6, 7
31, 4, 5, 6, 7
4, 5, 6, 7
3 , 4, 5, 6, 7
1
1
1
1, 2, .
1
1
1
1
1, 2
1
1, 2
1
1
1
1
1, 2
1, 2, 3, 4
1, 2, 3, 4
1, 2, 3, 4
1, 2
1, 2
1, 2
1, 2
1, 2, 3, 4
1, 2, 3, 4
1, 2, 3, 4
1, 2, 3, 4
1, 2, 3, 4
1, 2
1, 2
.
NSG Linux
rev.28.04.2014
75
. NSG
DTE/DCE NSG
DTE, DCE.
.
2 DTE DCE.
(MODE:EXT|INT|TTC) .
, NSG ( , DBH26m),
, , .
"" .
DTE DTE DCE
, . (male, "") .
DCE DCE DTE
, . (female, "") .
TTC ( DCE DTE), , DCE, DTE.
(DTE DCE), "" .
NSG ,
.
(male/female),
, ,
DBH26 (
NSG).
(gender changer, , DB25m/DB25m )
RS232.
,
NSG :
MVHSI UMHDLC
CAB V24 / DVI / MT
1
,
CAB V24 / D25 / MT / A
1 NSG:
CAB DBH26, DBH62, DVI, RJ45
CA5 DB25 ( )
CAS
2 :
V24 V.24/RS232
X21 X.21
V35 V.35
530 RS530
V36 V.36/RS449
530A RS530A
OCT - 8 RS232
3 , :
D9 DB9
M34 M34
D15 DB15
R45 RJ45
D25 DB25
MMOD RJ45f/DB25m CABOCT/R45/A
FDTE RJ45f/DB25f CABOCT/R45/A DTE
4 "" :
MT Male (""), DTE
FC Female (""), DCE
5 :
RS232 RJ45.
, ( )
, RS232 (V.24).
T V.35 TTC. , DCE
MODE:TTC MODE:INT, DTE TTC
DCE .
rev.28.04.2014
76
NSG
DTE
DCE
DCE
DTE
DBH26
V.35
DBH26
RS530
X.21
DBH26
DBH26
RJ45
(NSG)
RS232 async
DB62C
CABV24/D25/MT
CABV35/M34/MT
CABV35/M34/MT/T
CAB530/D25/MT
CABX21/D15/MT
CABV24/D25/MT/A
CABOCT/D25/MT
CABOCT/R45/A +
CABD25/MMOD
DB25m
M34m
DB25m
DB15m
DB25m
8 DB25m
8 RJ45m
RJ45f/DB25m
CABV24/D25/FC
CABV35/M34/FC
CABV35/M34/FC/T
CAB530/D25/FC
CABX21/D15/FC
CABV24/D25/FC/A
CABV24/D9/FC/A
CABOCT/R45/A +
CABD25/FDTE
DB25f
M34f
DB25f
DB15f
DB25f
DB9f
8 RJ45m
RJ45f/DB25f
NSG5xx DB25f
V.24
V.35
DB25
DB25
CA5V24/D25/MT
CA5V35/M34/MT
DB25m
M34m
CA5V24/D25/FC
CA5V35/M34/FC
DB25f
M34f
DBH26
DBH26
DBH26
RJ45C
CASV24/D25/MT/A
DB25m
CABxx/xx/FC
(. )
CASX21/D15/FC
DB15f
CASV24/D25/FC/A
DB25f
CASV24/D9/FC/A
DB9f
RS232
.
RS232
DVI
CABV24/DVI/MT
DB25m
CABV24/DVI/FC
DB25f
DVI
CABV35/DVI/MT
M34m
CABV35/DVI/FC
M34f
DVI
DVI
DVI
DVI
CABV36/DVI/MT
CAB530/DVI/MT
CAB530A/DVI/MT
CABX21/DVI/MT
DB37m
DB25m
DB25m
DB15m
CABV36/DVI/FC
CAB530/DVI/FC
CAB530A/DVI/FC
CABX21/DVI/FC
DB37f
DB25f
DB25f
DB15f
DB9
CAV232/D9/FC/A
DB9f
CAV232/D9/MT/A
DB9m
. CABV35/M34/xx TTC.
Cisco Systems.
NSG ( NPS7e, NSG509, NSG50 IDSL, NSG50 SDSL)
:
NSG5xx, NX300, NSG800, NSG900
NSG1000
CABV24/D9/FC/A ( CABV24/D25/FC/A)
CAVV24/D9/FC/A
IM485, IM4852 .
rev.28.04.2014
77
.
- RS232
RS232 ,
NSG, -,
DB25/DB9 - ( gender changer).
-
DB25f/DB25m
DB25
TxD 2
RxD 3
RTS 4
CTS 5
DSR 6
GND 7
DCD 8
DTR 20
- -
DB25f/DB25f DB25m/DB25m
DB25
2
3
4
5
6
7
8
20
DB25
TxD
RxD
RTS
CTS
DSR
GND
DCD
DTR
TxD 2
RxD 3
RTS 4
CTS 5
DSR 6
GND 7
DCD 8
DTR 20
-
DB25f/DB9m DB25m/DB9f
DB25
TxD 2
RxD 3
RTS 4
CTS 5
DSR 6
GND 7
DCD 8
DTR 20
TxD
RxD
RTS
CTS
DSR
GND
DCD
DTR
-
DB9f/DB9m
DB9
TxD
RxD
RTS
CTS
DSR
GND
DCD
DTR
3
2
7
8
6
5
1
4
TxD
RxD
RTS
CTS
DSR
GND
DCD
DTR
DB25
DB9
TxD 2
RxD 3
RTS 4
CTS 5
DSR 6
GND 7
DCD 8
DTR 20
3 TxD
2 RxD
7 RTS
8 CTS
6 DSR
5 GND
1 DCD
4 DTR
- -
DB9f/DB9f DB9m/DB9m
DB9
3
2
7
8
6
5
1
4
2
3
4
5
6
7
8
20
- -
DB25f/DB9f DB25m/DB9m
DB9
3
2
7
8
6
5
1
4
DB25
DB9
TxD
RxD
RTS
CTS
DSR
GND
DCD
DTR
TxD
RxD
RTS
CTS
DSR
GND
DCD
DTR
3
2
7
8
6
5
1
4
DB9
3 TxD
2 RxD
7 RTS
8 CTS
6 DSR
5 GND
1 DCD
4 DTR
,
, ,
DB25 DB9 . NSG
.
.
rev.28.04.2014
78
rev.28.04.2014