Вы находитесь на странице: 1из 19

1.

,

"BIOSPECT" "BIOSPECT-21"( ). Windows XP SP2 (. .5)
Multiscreening (Ultra),
.
2.
2.1.
.
:
;
, ;

, ;
, , , ;
.
2.2. .

:
,
, , ;
- ();
-, SPA
1

;
, ;
.
3.
/
1.
2.
3.
4.
5.
6.
7.

,
2205
,
505
,
4,9
( ),
min 5000

5
,
,
22016550
,
1,6

: (Safety of
information technology equipment) 60950-2002

26329-84 (.. 1.2.,1.3.)(
35.160, 69)
. - 51318.22-99 ( ).
51318.24-99 ( 24-97) - . .
51317.3.2-99 ( 61000-3-2-95) - . 16 ( ). .
51317.3.3-99 ( 61000-3-3-94) - . ,
16 ( ), . .
2


9.303-84 .
"", .2 15150-69.
23256-86.
4.
1 2.

. 1. .

1. ;
2. ;
3. ;

.2. .

4. ./. ;
5. ;
6. ;
3

7. ;
8. .

Multiscreening Ultra.
USB.
(, ) .

, ,
.
5. ,
.
5.1. .

1. Windows XP SP2.
2. - Pentium IV 1,8 .
Windows Vista/7
6,0 ( : - Windows - ).
3. 1024 M.
4. , 1024768,
32 .
5. ( ).
6. 1 .
7. USB.
8. CD-.
5.2. .

1. -
CD-. setup.exe -.
Windows Vista/7 setup.exe
.
setup.exe
:

, .
2. .
2.1. ( -
-). .
2.2. , :
- Window Update?
, ;
- ;
- .
;
- -
Drivers\Device, ftdibus.inf, ;
2.3.
.
2.4. (
)
USB Serial Converter ( USB):

USB Serial Converter , VCP (. . 3).


5

. 3.
! , , .
(
)
NLS diagnostic device,
, , , - Drivers\Device.
3. . USB. . ,
: (MultiscreenUltraRemove Hasp
Driver MultiscreenUltraInstall Hasp Driver).
4. 1024768, 32 .
5. -100% ( Windows
XP2/Vista , ). : 6

- 100%.

: Windows Vista/7
:
- -
-, , .
, : / FTDI FTD2XX
USB Drivers, . 2.
5.3. .

5.3.1. , Windows, Windows


,
( : Control Panel Regional Settings Language
Advanced Language to use: Russian).
5.3.2. .
5.3.3. .
5.3.4. USB .
5.3.5. USB. .
5.3.6. ( 4).
5.3.7. , , : R , L .
5.3.8. (
Multiscreening Ultra Windows.). Windows Vista/7
(
, 7

). .
:
:
! .
Ok .
! ,
. .2.4.
.
6.
6.1.
, ,
, .
6.2. 10 35 80 % 25 . , .
7.
7.1. , .
7.2.
, .
.
7.3.
42-21-2-85 , 1% 70% .
7.4. :
- ;
- .

, 5962-67.
8

8.
8.1.
, 24
.
.
8.2.
, , ,
,
.
8.3. ,
(, , , ), , , .
8.4. , .
.
8.5.
.
30 . , ,
.
8.6
.

9.
/

1.
Biospect-21
2.

3.


4.
(USB)
5.

6.
- (CD)
7.
HASP HL (USB)
8.

9.

: Biospect-21
: ________________

:___________

___________
..

10

1
1
1
1
1
1
1
1
1

1. INTRODUCTION
This operating instruction applies to the data processing device BIOSPECT of model BIOSPECT-21 (hereinafter device) and is intended for
learning its characteristics, operating principle and service regulations. The
device works only on computers with Operating System Windows XP SP2
or higher (see p.5) and with software Multiscreening (Ultra) developed
by the manufacturer.

2. DESIGNATED PURPOSE
2.1. The device is designed for computer non-linear analyze and modeling
the state of different biological structures. It allows to:
asses the adaptive resources of the investigated systems;
reveal and assess different factors that have an adverse impact on the
development of the system;
simulate interactively the basic methods and tools to facilitate the normalization of the state;
evaluate efficiency of different preparations, nutriceuticals and parapharmaceuticals, herbals and homeopathy;
analyze dynamics of changes in functional state during the recovery
process.
2.2. This device does not belong to the class of medical apparatus and
shall not be registered at the Committee for certification and licensing of
medical activity.
The device has a high adaptability and provides many opportunities to use
in the following areas:
in companies that distribute nutritional supplements, ecological clean
and sports nutrition, hygiene;
in fitness centers;
in cosmetic and SPA salons;
in individual work of psychologists;
in the staff recruitment on specific positions;
in the educational and scientific work in health services.
0

11

3. TECHNICAL PERFORMANCE

1.
2.
3.
4.
5.
6.
7.

Name
Supply-line voltage, V
Network frequency, Hz
Generator carrier frequency, HHz
Service life (uninterrupted operation), hour
Maximum sound pressure in headphones
does not exceed, dBA
Dimensions, mm
Max. set weight, kg

Value
2205
505
4,9
min 5000
5
22016550
1,6

The device corresponds to : Safety of information technology equipment 60950-2002


Allowed noise levels of computers and data processing systems correspond to 26329-84 (1.2., 1.3.).
Electromagnetic compatibility. Radiointerference level from equipment of information technology - 51318.22-99 ().
51318.24-99 ( 24-97) Electromagnetic compatibility. Stability of information technology equipment to electromagnetic interference.
51317.3.2-99 ( 61000-3-2-95) Electromagnetic compatibility. Emission of current harmonics by technical equipment with the
consumed current of not more than 16A (single phase). Standards and test
methods.
51317.3.3-99 ( 61000-3-3-94) Electromagnetic compatibility. Voltage fluctuations and flicker caused by technical equipment
with the consumed current of not more than 16A (single phase), connected
to the low voltage power supply systems. Standards and test methods.
Metal and semi-metal coatings comply with GOST 9.303-84 for operation conditions group.
Regarding operation conditions the device belongs to climate version
, location category clause 2 according to GOST 15150-69.
Depending on eventual sequences of operation failure the device belongs to class B according to GOST 2356-86

12

4. DESIGN AND OPERATION PRINCIPLE


The appearance of the Biospect-21 device is presented on Fig.1 and
Fig.2.

Fig. 1. Front panel

1. connect-on indicator of magnetic inductor (headphones);


2. test indicator;
3. power-up indicator;

Fig.2. Rear panel.

4. power on/off button;


5. socket for supply cable connection;
6. socket for personal computer connection;
7. socket for testing glass connection;
8. socket for headphones connection;
13

The device operation is controlled by Multiscreening (Ultra) software. The communication with PC is realized via USB. The device and
corresponding software operate on the basis of mathematical analysis and
comparison of the received signals from headphones and testing glass. The
principle of equipment functioning is based on modern developments in
the field of electronics, computer simulation and using of modern databases.
5. MINIMAL REQUESTS FOR A COMPUTER, PREPARATION
AND PROCEDURE OF OPERATION WITH THE EQUIPMENT
5.1. Minimal requests for a computer.

1. Operational System not less than Windows XP SP2.


2. CPU - Pentium IV not less than 1,8 GHz. For the operational systems Windows Vista/7 it is recommended a processor with an experience index not below than 6.0 (according to your operational system: Control Panel System - Windows Experience Index - Processor)
3. RAM - 1024 Mb;
4. Video card supporting the TrueColor mode 32 bit with 1024x768
resolution;
5. Printer (advisable color);
6. Not less than 1 Gb free space on a hard disk;
7. Two free USB ports;
8. CD-ROM drive.
5.2. The software installation.

1. Insert the installation compact disc into CD-Rom drive. Start the
program Setup.exe from the root folder of the installation CD. Setup.exe
should be run with the rights of Administrator in operational systems Windows Vista/7: click by the right mouse button on the file Setup.exe and in
the appeared menu choose Run as Administrator. During the installation
follow the instructions appearing on the screen.
2. Install device driver.
2.1. Turn on the device (the installation compact disc should be inserted into CD-Rom drive). Windows detects a new hardware and starts
installation of device driver.
14

2.2. The Found New Hardware Wizard may appear on the screen.
Select No, not this time and click Next. Select Install from a list or specific location and click Next. Then specify the driver location: installation
CD\Drivers\Device.
2.3. After successful installation on the screen appears the following
message: The hardware is ready.
2.4. Open the Device Manager (StartControl PanelPerformance
and MaintenanceDevice Manager) and then find in USB Controllers
USB Serial Converter. Click twice on the USB Serial Converter to open its
properties and in the appeared window on the second page uncheck the
loading of VCP (see pic.3).

Pic.3
Attention! In the case of a failed device driver installation, a
correspondent message appears, you must install it manually. Open the
Device Manager (Start Control Panel System and Maintenance
Device Manager) and find the row NLS diagnostic device, double click on
that line and in the properties, on the page Driver, select "Update" and run
the driver installation manually by specifying its location on the
installation CD-ROM - folder Drivers \ Device.

15

3. Install dongle driver. Insert the dongle into USB-port. On the dongle the red indicator should light up, otherwise it is necessary to reinstall
the dongle driver. (StartProgramsMultiscreenUltraRemove Hasp
Driver and StartPrograms MultiscreenUltraInstall Hasp Driver).
4. Set the screen resolution 1024768, mode 32 bit.
5. Set the font size - Small 100% (for OS Windows XP2/Vista this
parameter is called the scale, you must install the standard scale). Do the
following: Start Control Panel Appearance and Personalization
Fonts Change the font size, select in the list - Small 100%.
The program is installed and ready to run.
Note for Windows Vista/7:
If the following message appears Insert the installation compact
disk (it is already inserted). It means there is the old driver version presented and it is necessary to remove it: Start Control Panel
Add/Remove Programs FTDI FTD2XX USB Drivers, click Remove.
Then begin from the point 2.
5.3. Preparation and procedure of operation with the equipment.

1. In case of not Russian version of operating system, its necessary


to set the Russian language as current language for programs not
supporting Unicode (Control Panel Regional Settings Language Advanced Language to use: Russian);
2. In the operating system setting disable sleep mode and turn off all
screen savers.
3. Connect all peripheral units to the device.
4. Connect the device to the computer using the USB-cable supplied.
5. Insert the dongle into USB-port. On the dongle the red indicator
should light up.
6. Turn on the device (button 4).
7. Before beginning of a test put on the headphones in accordance
with marking.
8. Start the program (click an icon on the Windows desktop). In the
operational systems Windows Vista/7 start of the program should be executed with the rights of Administrator (click by the right mouse button on
the program icon and in the appeared menu choose Run as Administrator). Further operation stages are described in user manual in details.
16

Note! If when you start the program with turned on device a message
appear.
No signal! The program will be closed.
Click Ok button and start the program again.
Attention! When you see this message again, please check the
correctness of the device driver installation - see p.2.4. from the section
"The software installation".
6. TRANSPORT AND STORAGE
6.1. The device can be transported by all transport means, except
for non-heated sectors of airplanes according to cargo regulations valid
for the appropriate kind of vehicle.
6.2. While short-term storage the device shall be stored in a closed
room at the temperature of 10 350C and relative humidity of 80% at
250C. The air in this room shall be free of inclusions causing corrosion.
7. TECHNICAL MAINTENANCE
7.1. The device is sent to the customer carefully checked and shall
provide no-failure operation for a long time, provided that the equipment is
maintained clean and protected against mechanical defects.
7.2. It is recommended to remove the dust from the surface of the
device first with a wet napkin, then with a dry one. Use of synthetic
cleaners and organic solvents is forbidden.
7.3. According to OST 42-21-2-85 the internal surface of headphones
shall be disinfected twice before installation with coarse calico or gauze
napkin wetted with 1% chlorine solution or 70% alcohol solution.
7.4. While maintenance the following shall be checked:
- the quality of network cable insulation;
- cleanness of connectors of peripheral units.
If required, the connectors can be cleaned with soft brush wetted
with ethyl rectified spirit GOST 5962-67.
8. WARRANTY OF THE MANUFACTURER
8.1. Warranty period is considered 24 months from the date of
putting the equipment into operation, provided that the customer has observed all operation, storage and transport conditions.
17

Within the warranty period the manufacturer shall repair the


equipment free of charge.
8.2. The manufacturer shall feel free to reject the guarantee repair
in the event of mechanical damages, broken or damaged guarantee seals,
binding bonds of the housing, traces of breaking up on the internal surface
of the device, unauthorized repair or charge of the internal communication.
8.3. This warranty shall lose force at lost vendibility of the article,
casual damages (those caused by client, animals, hexapods), damages
caused by water and other liquids, as well as unstable electrical network or
a natural disaster.
8.4. The requirements of this warranty do not provide for any periodic service, repair or replacement of parts in case of violation of operating
standards. In all such cases the parts can be repaired or replaced for a separate charge.
8.5. The out-of-order equipment should be transported to the workshop by means of the client.
The term of the repair service shall be at most 30 working days.
Replacement of the devices, not subject to repair, shall be effected subject
to the original packaging of the device present.
8.6. The manufacturer is not answerable for improper use of the device and interpretation of the results.

18

9. COMPLETE SET OF DELIVERY


Item
Name
1.
Device Biospect-21
2.
Headphones
3.
Testing glass
Tools and accessories
4.
Interface computer cable (USB)
5.
Power supply cable
6.
Software (CD)
7.
Dongle HASP HL (USB)
8.
Packing bag
Documentation
9.
Certificate

Quantity (pcs.)
1
1
1

Name of model: Biospect-21


Serail number: ________________________

Date of sale: _____________

Signature___________

19

1
1
1
1
1
1

Вам также может понравиться