Вы находитесь на странице: 1из 136

PCM30U-OCH

nemec@marconi.2c.cz

PCM30U-OCH
(, , )
PCM30U-OCH 3-




()
TOPONET

(PCM30U-OCH)
Analog
1
POTS A/D
2/4w E&
3w
a,b polarity
tone
2
SIG 4 5
Data 3
V/X <-64kbit/s V110
V/X Nx64kbit/s Bu. X NI
MC OPTO
64kbit/s CODIR Code. E1
Ethernet HDLC
Teleprotecvon
protocol
command
sampling
50Hz phase
Dif.prot. OPTO Code 6

1.
2. (PCM) 1-
3.
4. 1- (RM1) ITU-T G.703
5.
6.
PCM30U-OCH

1. 2.
SA/TJ PW CJAB/RJ1,PBS
DZP
3UST / 3OCH2 SDH
4UOCH
6OCH4/8

MT1 ROK 6OCH3

APS

PCM30U-OCH
SDH
..

- SDH
SNMP
( )
IP

(ISDN, Ethernet)
( ,
)
E1



,

PCM30U
3.
CJA6, SMI (SNMP), SDH,

6AL08 6AE12

3ALC

1AE
PCM30U-OCH -

( 80) , ( 2 )
250 VDC/4 A
, 50
- (7SD523, 7SD61, 7SD512, SEL311.L, REL316, REL551, REL551)
-

LAN
2/4
RS 232, 485, 422, X.21, V.35 ..
Ethernet 10/100/1000
SDH SFP
PDH 220
GPS


GPS


, ,
, ,
PCM30U-OCH -
PCM30U-OCH





(/)

( ) - 220
(64 /)
E1/E2/STM1-4/ (E3)
(,
)
6HU
3HU / 1HU

220

IEC 870
IEC 60834
, , ...

50


(10 -24 )
(< 2 )
/A (240 /4A ..)

(Siemens, ABB, SEL)



Siemens SEL ABB

7SD523 7SD61. 7SD512 SEL311.L REL316 REL551 RED670

SOC DUO SL8 SL13 FX RD8 RD13 820 nm


1310 nm
CJA6
PCM30U.OCH
PCM30U-OCH 3AL


/

/


GW (RJ1
SMI)

48VDC
2 x 6U (, , 20 )
. 6 x 3U (, , )
PCM30U-OCH 6AE12

48VDC

12 x 6U (, , 120 )
. 11 x 3U (, , )
PCM30U-OCH 6AL08

()
PDH

6AL10 1xSDH

6AE12
SDH (
120 )
SDH

RJ1 / SMI

NP110/1

NP110/2
NP110/1

NP110/2

IFU/1

IFU/2
IFU/1

IFU/2

SMI

PCM30U-OCH
PCM30U-OCH
PCM30U-OCH
PCM30U-OCH
21 22 25 23 24 21 22 25 23 24

DXS/1

DXS/2
JRxx/2
JRxx/1

U100, CJA6/2
U100, CJA6/2

CJA6/1
ASDH4

CJA6/1

U234
U234
U234
U234

U234

U100
U100
U100
U100
U234

U234
U234

U234
U234
U234
U234

U100

U100
U234
U234
U234

U234

U234

U100
U100
U100
U100
U234
U234

U234
U234
U234

U100

U100
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20
1 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20

Cable guide
lita pro upevnn kabele

2 SDH - 8x STM-1 4x STM-4


- . STM-1, E1, Ethernet
2x10/100/1000 Base-T 2xGBE/SFP SDH
8 6U (, , 80 )
7 3U (, , )


PCM30U-OCH 6AL08

NP110/1

NP110/2
IFU/1

IFU/2
SMI

PCM30U-OCH
PCM30U-OCH

21 22 25 23 24

DXS/1

DXS/2
U100, CJA6/2
ASDH4

ASDH4

CJA6/1
U234
U234
U234
U234

U234

U100
U100
U100
U100
U234

U234
U234

U100

U100
1 3 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20

6U (80 ) + 1U 6AL08 446R787


Cable guide
6U (100 ) + 1U 6AL10 446Rxxx
6U (120 ) + 1U 6AL12 446Rxxx
EMC-
MC COVER 446K617
(4 ) CJA6 446P540
- 161 DXS 446P747
M IFU 446P583
. RJ1 446P598
SNMP SMI 446P743
NP110 446P585
2 x STM1 ASDH4 HPX-800-DC-24E1DS1
2xRM1 JRM 427P845
, A 50 (PBS)

(6U)
(3U)

EMC



RD
<449

ASDH4 cabling

PBS cabling
Top view

max. 132
Grounding
80 max. min 6mm 2
132

92
(97 se rouby)
430
463

241
298

Front pannels
montn rovina stojanu 57

33
Front cover

19 "
RD
Grounding
Side view
max. 132

max. 132
60 30

Next Equipment

min 1U

PBS
cabling Front
pannels
ASDH4
cabling Front

(Front cover)
6U cover
(265,9)

312
Subscriber
cabling

1U
(45 + kabel)
Cable Cable guide
guide

min 2U
(po dohod s Vackem)

Next Equipment

301
pedn hrana 6AL08

381
-
100 km 1310 nm

PDH


220 km 1550 nm

SDH 15-180 km 1310/1550 nm


(SFP)
S x.1 - 15 km
L x.1 - 45 km
L x.2 - 80 km
L x.2+ - 120 km
L x.2++ - 160 km
L x.2+++ - 180 km
SDH/SFP
Maximum Minimum Maximum Minimum Max. power Min. power
Input Level Input Level Output Level Output Level budget budget
I-1.1 -8 dBm -23 dBm -8 dBm -15,0 dBm 15,0 dBm 8,0 dBm
S-1.1 -8 dBm -28 dBm -8 dBm -15,0 dBm 20,0 dBm 13,0 dBm
L-1.1 -10 dBm -34 dBm 0 dBm -5,0 dBm 34,0 dBm 29,0 dBm
L-1.2 -10 dBm -34 dBm 0 dBm -5,0 dBm 34,0 dBm 29,0 dBm
L-1.2+T -7 dBm -43 dBm 5 dBm 1,0 dBm 48,0 dBm 44,0 dBm
L-1.2+S -10 dBm -45 dBm 5 dBm 1,0 dBm 50,0 dBm 46,0 dBm
L-1.2+SE -10 dBm -45 dBm 8 dBm 5,0 dBm 53,0 dBm 50,0 dBm
I-4.1 -8 dBm -23 dBm -8 dBm -15,0 dBm 15,0 dBm 8,0 dBm
S-4.1 -8 dBm -28 dBm -8 dBm -15,0 dBm 20,0 dBm 13,0 dBm
L-4.1 -8 dBm -28 dBm 2 dBm -3,0 dBm 30,0 dBm 25,0 dBm
L-4.2p -8 dBm -34 dBm 2 dBm -3,0 dBm 36,0 dBm 31,0 dBm

S x.1 - 15 km
L x.1 - 45 km
L x.2 - 80 km
L x.2+ - 120 km
L x.2+SE - 180 km

Fibre a2enuaon (dB/km) 0,22


Output power (dB) -5
Rx sensivity (dB) -34
Power budget (dB) 29

Distance (km) 195


/ Number of km/connector 50
Number of connectors 4
A2enuaon/connector (dB) 0,5
/ Number of km/weld 3
Number of welds 65
Aenuavon/weld (dB) 0,03
. Total bre aenuavon 42,9
. Total connectors aenuavon 2
. Total welds aenuavon 1,95
Reserve (geng older)
. Reserve (general) 3
. Total aenuavon 49,85
PDH

+
ASDH4 (1)

PCM30U-OCH
(, , )
PCM30U-OCH 3.




()
TopoNet

NP110 48VDC
FU1 -

FU2

40 72 VDC
2 x NP110 ( )

CJA6 E1

1 8 (4 )
( IFU)

CJA6 E1
4 x E1 (A ,B, C, D) - A B IFU
1/G.703/120 IFU JR
4 x M1 - M4
(1 2x (JRxx).
CRC4, E1, .
, , E1,
GPS,
(LM )
(FW)

TPR.2
TPR.3 (2 1)
TPR.4
TPR.5 (2 )
TPR.6 (4 1)
TPR.7

TPR.8
TPR.10 / CJA6 DXS
CJA6 a
RM1

2048 /
50.10-6

HDB3
120 W
75 W
ITUT G.703, 10.2
3 / 120 W (2,73 /75 W)

0 0,3 / 120 W (0,237 /75 W)


ITUT G.823, . 3.1.1
2 6 UI
10 100 0,4 UI
CJA6 E1
CJA6 Upgrade

DS2
pack
JRM_xx-yy.eprj
ST M29W010B
SmarProg2
IFU

1 CJA6
2 x E1/G.703 CJA6
GPS
(2M)
MSG ( -
PCM30U-OCH)

IFU
IFU
XC1

1 2 1 .
(Urgent) .
2
3
3 L/R=40
50 . 1 A 0,5 A
4 5 4 .
(Non urgent)
5
6 110 . 0,5 A 0,22 A
6
7
8 220 . 0,3 A 0,1 A
7
8 (Indicative)

9 9 300 . 0,25 A 0,06 A

E1a E1b
ASDH4-1 (2)
SA7 E1a E1b
E1.6
SA6
E1.5
E1 E1

SA1 SA3 SA2 SA4


IFU1 (2)

a1 a2 b1 b2

a b a b

CJA6.1 CJA6.2
IFU
SA1, SA1 A
SA2 E1 E1a
SA2
CJA6. E1b
SA3, SA3 A V.11 +
SA4 E1 E1a
SA4
CJA6.S SA5/1 TIK (RGP)
E1b
SA5/2 DATA (RGP)
SA6, SA6 E1a SA5/3 . .
SA7 E1 5 SA5/4 M
ASDH4 SA7 E1b 120
6 V.11 -

SA5/1 TIK RGP


SA5/2 DATA RGP
SA5/3 2048
SA5/4 M
JRxx -

JRxx
, x :
M E1/G.703/RJ45
O 1310 1550nm, FC/PC, 2.

() CJA6

( 220)1
21 22 25 23 24
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20
JRxx - LT ()

E1 / LT
H.O. (2 4xE1) - ITU-T G.
742
LT
E1 / G.703 / 120 Ohm
E2 / G.703 / 75 Ohm
OPTICAL MM, SM 1310 1550 nm 850 nm (.)
JR
- (FW) +

JRxx

JR JRO JRMO JROO(2) JRM2




2x
2xRM1 OLT OLT OLT OS OLT RM2 RM2

RM1

JR JRO JRMO JROO JRM2


mother board 1xE1 OPTO 2xE1 G.703 2xE1 OPTO 2 x
1xE1 OPTO 4E1/E2 G.703
for OLT or
or
JROO2
2x RM1
JRM 2 x
4E1/E2 OPTO
2x
RM2 OS
RM1 JRM
2xE1 G.703
JRO/L
4096 / 16896 /

MCMI
(
)
1310 / 1550

3
> - 8 / > - 3 > - 6/-5

. BER < 10-10 > -45 > -46

. BER < 10-10 < -3

LD 40 / >48 > 50
FC
FC
SM (ITU-T G.652)

GI (ITU-T G.651) JRO


JRO(L)
4 .
JRO JROL
1 2 3
50

40

30

20

10

[]
10 50 100 150 200 250

1
2
0,5 /, 1310
0,35 /, 1310
JRO: 0 -100
3
0,2 /, 1550 JROL: 45* - 230

0 0
OT OR
1

OR 0 OT
1 1

3 dB
100 %

JRM
JRxx Upgrade

DS2
pack
JRM_xx-yy.eprj
ST M29W010B
SmarProg2
ASDH4 SDH - STM1/4

6AL08 6AL10
( )
4x STM-1 2x STM-4 + 2x STM-1 (SFP)

STM-1,
(4 + 24) x E1, 2 x E1 IFU
2 x Ethernet 10/100/1000Base -T + 2 x GBE/SFP
SNCP MSP
VC12 VC4, VC
ALS
1
5
OT 2 OR

3
OR 4
OT

1
2 - LOS OR
3 - OT
4 - LOS OR
5 - OT
1
ALS
DXS (12+4) x E1

12- 1
4- ()
( + )

DXS (12+4) x E1
DXS1/0 16xE1
12 x E1/G.703, 12 .
E1 (G.704)
16 ( )
CRC4 ( )
AIS

.E1
IFU

CJA6
(1+1)
2 DXS

1
SLAVE N x DXS
DXS (12+4) x E1
DXS
( )
. (
K.) , - ,
.
broadcast K .
, - .
- ,
.


.
:






pfg.
Connecter .

:

M1 A1, M17A17, M2A2, M18- A18 M15 A15
M3 B3, M19 B19, M4 B4, M20 B20
M5 C5, M21 C21


M6 M6
M22 M22
Broadcast
M12 A12 A24 M7
M12 A13 A24 M8
M12 A14 A24 M9
PCM30U-OCH
. ........... TS = 64kbit/s M 2Mbit/ E1 2Mbit/ STM1
1 s s 155Mbit/s
2
... Eth. ASDH4

PDH
/

1

30
DXS N x VC12
1
A


, , /

2 1 63x VC12
PDH
... 2 SDH

PDH
B
/
X
1
3
30 4 12 x E1 28 X C





(TS)
1
2

(VC12)
D
31
... 12 x E1
PDH

/
1


30
4 x E1
1 C,D STM4
2 622Mbit/s =
...
PDH

252 x VC12
1

/
30
4 x STM1

PDH SDH
SDH, PDH



(2xMUX)
2xDXS CJA6
2xE1 SYNC 12 x E1 2xE1 SYNC 12 x E1
- - - - - - - - - - - -

IFU IFU


CJA6 DXS CJA6 DXS

SYNC BUS

Force Master
Auto Master
Slave

SMI -
SNMP
SMI
6AL08 6AL10

GW ( SNMP)
RJ1 KJ
2 x 10/100BaseT (RJ45)
IP = 192.168.111.111/24
IP LMS-OCH NE
VLAN (802.1Q)
(802.1p)

SMI

SMI
prava na komunikan desce v pozici
. XJ6 XJ8 XJ4 XJ2 XJ3 XJ37 XJ32 kde je SMI
6OCH5 BP6 S4 (KJ) 1-2 1-2 1-2 1-2 1-2 1-2 1-2
6OCH5 BP6 R (RJ1) 2-3 2-3 - - - 2-3 2-3 c1 GND
6AL08 BP08 S4 (KJ) 1-2 1-2 1-2 1-2 1-2 1-2 1-2
6AL08 BP08 R (RJ1) 2-3 2-3 1-2 1-2 1-2 2-3 2-3
M . ac7,
6OCH4 KOCH4 KJ - - - - - 1-2 1-2 ac8
6OCH4 KOCH4 R (RJ1) 2-3 2-3 - - - 2-3 2-3 c1 GND
M . ac7,
6OCH3 KOCH3R KJ - - - - - 1-2 1-2 ac8
6OCH3 KOCH3R R (RJ1) 2-3 2-3 - - - 2-3 2-3 c1 GND
6AE12
SMI ( )

Reboot:
(
),


.


.
Upgrade:
rmware
. ()
firmware flash firmware
rmware
ash



(

firmware Backup).
Backup:
rmware

PCM30U-OCH
(, , )
PCM30U-OCH 3.




()
(DORIS, TOPONET)

PBS/4PBS /10/4

(. ): 24, 48,110, 250 VDC ()


24 VDC
: 4x 250VDC/4A + 6x 250VDC/1A


-
PBS PBS

24220 Vdc 14 4x 4A /250Vdc

24220 Vdc 610 6x 1A /250Vdc


kvitovn

- + 1. alarm
24 V
2. alarm

- ERR1 ERR2
GPS
1-4
OPTO coupler/EM relay 1-4
11-


-


0,60,7

IN OUT

A A A

&
B BQ BQ

&
A AB AB

A B
A B
A

B B
A B
A

50 s Default
1 24 ms

PBS PBS
Command

1 24 ms 1 24 ms
PBS PBS
Command

Limit
100 10 000 ms

PBS PBS
Command
PBS GPS

GPS GPS

RGP RGP

V.11 IFU IFU

PBS PBS
00.001 00.003
GPS

(Tts)
( )
1x() 2x 4x
64 / 2 4 8
128 / 1 2 4
256 / 0,5 1 2
512 / 0,25 0,5 1

(Ta)

14 1 4
5 10 1 1

1 1
BUS BUS
A KI KI A
A

10
10
BUS BUS
KI KI

- (A B) ,
(M1, M2) KI
(A, B) , ()

. 2KI (128 /) ~ 5 .
PBS 2- 4PBS

PBS 4PBS.
PBS. ,
.

PBS1 PBS2

IN 1
IN 10



OUT 1 2 /
(128 /)
OUT 10


PBS ,
. (
), .
TEST 500. ,
.
LED TEST. 500,
,
.
PBS (3)
X21
X21
RO4 50

. 1,5
+/- 3VAC


50 - 16

160 samples 320 samples


2 x 64 kbps

0 ms 20 ms

10 50 Hz
samples
RO4 4
2 x , 50 Hz
E1 / 4 x 64 kbit/s (4 x TS)

4 .




breaker HV line breaker

PCM30U-OCH PCM30U-OCH
RO4
2Mbit/s RO4
transmission
2x 2x
RO4
PCM
50Hz 50Hz

16 (1,5 %)
max 65/112,5 V AC / 2 or 5 kOhm
max 57 V AC / 2 or 5 kOhm
max 100 V AC / 1,2 kOhm

5 W

5 10
(
)
cca 0,3 ms
0 24 ( 0,5)

LOS ( )
LOS 2 Mbit/s


PCM30U-OCH
(, , )
PCM30U-OCH 3.




()
(DORIS, TOPONET)

DCE
(DU8, DU2P, SD4, XB2U, BRI8, BRI2)

PCM30U-OCH



DU8, DU2P, SD4, DU8, DU2P, SD4,
XB2U, BRI8, BRI2
XB2U, BRI8, BRI2

TxD E1 TxD
RxD RxD
TxC TxC
DTE RxC DCE DCE RxC DTE

Handshake Handshake

(TS1-15,17-31)
handshake TS16
TS16
PCM30U-OCH ( ) =
DTE
DU8
( 8 )

( 512 /) ( 38,4/)
hand-shake K
- (PTP PTMP)
DU2P
( 2 )
DU8 .
.
: RS232/V.28, RS422/V.11(X.21), RS485-4,
RS485-2, V.35, RS449,V.36, RS530
/
:
600, 1200, 2400, 4800, 9600, 19200, 38400 /
:
: 600, 1200, 2400, 4800, 9600, 19200, 38400, 48000, 56000,
64000, 128000, 256000, 512000 /
5 8 ,
: , 1-2
: 102, 103, 104, 105, 107, 108, 109, 114, 115

DX21, DV24. DX21 DV24 KI16. DU8


+ 64 kbit/s. Hand-shake .
1.
KI16. .
DU8 / 2
1 x TS

( ITU V.110)
N x TS N x
64/

(RS232/V.28, RS422/V.11, RS485-4w,
RS485-2w, V.35, RS449, V.36, RS530)
,
tester 215

1-4 RTS, DCD, DSR, DTR.


5-8
RxD, TxD, RxC, TxC.

4 ,
8 .
SD4 64 / -
CODIR (G.703)

4 x E0 (64/ CODIR (G.703)


,

SD4 -
: 64 / 100
(100 ppm)
3,9
: 120
1
0 0,1
ITU -T G.703
XB2U
Ethernet 10/100 BaseT

EoPDH (HDLC) n x 64 / (n = 0 30)


2 x Ethernet 10/100 BaseT (RJ45) ()
64 1533
K16
( ) ( )

XB2U
2
LAN

Ethernet
,


Ethernet- 64 1533
100BaseTX
autonegotiation
CSMA/CD SN ISO/IEC
8802-3
bridge SN ISO/IEC 8802-1
- HDLC
SN ISO/IEC 8802-3
- n x 64 / (n = 0 30)

2 x RJ45
100 /
LED- Ethernet-
HDLC
10M / 100M
. 2
BRI8, BRI2
ISDN S0

BRI8 ( 8 ) - 6U, BRI2 ( 2 ) 3U


2B+D, ITU-T I. 430
LT-T LT-S
, 215
BRI8, BRI2

ISDN S0 (2B+D)
8

192 /
144 /
B B1, B2 2 x 64 /
D 16 /
48
4

- 40 ( -34 - 42 )
. 120 mA
ITU -T I.430

8 . 500
BRI8, BRI2

< 500 m
< 100 - 200 m
< 25 - 50 m
TE1 TR BRI8

BRI8 TR BRI8
TR
< 1000 m < 10 m < 10 m

TE Terminal Equipment TE1 TE2 TE3 TE4


TR Terminal Rezistor (100 ) TE1 TE2 TE3 TE4

PCM30U-OCH
(, , )
PCM30U-OCH 3.




()
(DORIS, TOPONET)

EMW10 2- / 4- .
E&M

EMW10 ( 10- ) - 6U
215 .
- Master/Slave
Omnibus ( DIK)
EMW4 2- / 4- .
E&M

EMW4 ( 4- ) - 3U
215 .
- Master/Slave
Omnibus ( DIK)
EMW10/4
/
10
600 300 3400 20%
G.711 /
/ 14 / 17 4
/ +4 / 17 4
0,5
E&M
. 130

. 100 .

U ( 48 )

. 5
(. )
( ) . 2
4

EMW10/4
a c
32a, 32c
16 GND . M 4.
31a, 31c E, M 10-
30a, 30c E, M 9- 15 ERR E 4.
29a, 29c E, M 8-
28a, 28c E, M 7- 14 b / (2.) 4. b 4.
27a, 27c E, M 6-
26a, 26c E, M 5- 13 a / (2.) 4. a 4.
25a, 25c E, M 4-
12 M 3.
24a, 24c E, M 3-
23a, 23c E, M 2- 11 E 3.
22a, 22c E, M 1-
21a, 21c / (2.) 10- 10 b / (2.) 3. b 3.
20a, 20c 10-
19a, 19c / (2.) 9- 9 a / (2.) 3. a 3.
18a, 18c vstup 9-
17a, 17c / (2.) 8- 8 GND . M 2.
16a, 16c 8-
15a, 15c / (2.) 7-
14a, 14c 7- 7 E 2.
13a, 13c / (2.) 6- b / (2.) 2.
12a, 12c 6- kanlu 6 b 2.

11a, 11c / (2.) 5. a / (2.) 2.
10a, 10c 5. 5 a 2.

9a, 9c / (2.) 4-
8a, 8c 4- 4 M 1.
7a, 7c / (2.) 3-
6a, 6c 3- 3 E 1.
5a, 5c / (2.) 2-
4a, 4c 2- b / (2.) 1.
2 b 1.
3a, 3c / (2.) 1-
2a, 2c 1-
1a 1 a / (2dr.) 1. a 1.
1c
UII10/4
FXS

UII10 ( 10- ) - 6U, UII40 ( 4- ) - 3U


: , 600
. /
. 6U 6xFXS/FXO/LB UNIV (2.Q.2012)
215 .
. ( UT)
PCM30U-OCH +

PCM30U
PCM30U
PCM30U
PCM30U


-OCH -OCH -OCH -OCH
UI10
FX

UI10 ( 10- ) - 6U
: , 600
. /
. 6U 6xFXS/FXO/LB UNIV (2.Q.2012)
215 .
. ( UT)
UI10/UII10

10

( ) 600 20% 300 - 3400
G.711 / A

/ -3 / -7 3

/ -4 / -8 1

0,5
ITU-T Q.552
>1 M

< 300
6 10
. 10 A / . 100

. 8 k
25-50
20
25 - 50
. 75
8 12

/ 1,4 1,8 /1
. 2
BIN . (8x In / 4x Out)
BIN . (8x./ 4x.)


PCM30U-OCH

BIN8 BIN8




BIN8


BIN


8xI / 4xO 2 (4xI/2xO)
, (-24)
Mx
GER8 Fast Ethernet
2 10/100/1000 Mbit/s
6 10/100 Mbit/s
16 TDM 1.Q. 2012
L2 / L3
M1-4 TDM PCM30U-OCH

PCM30U-OCH
(, , )
PCM30U-OCH 3.




()
TOPONET
PCM30U-OCH
,





(
)


BER 2 Mbit/s

P ERR = 4 p 4

30U-OCH 30U-OCH
PBS LOG LOG PBS

Command
PCM30U-OCH

- Path-protecon
(
drop/insert )

Full-protecon -
PCM30U-OCH
path PCM30U-OCH
protection


PCM30U-OCH PCM30U-OCH

full
protection

PCM30U-OCH PCM30U-OCH


6AL08 2xCJA6
( )
STM ASDH4 STM

E1/G.703

IFU

KJ
KJ
CJA6 CJA6 KJ

BUS


CJA6 1+1 STM1(4) Transit STM1(4)

ASDH4 ASDH4

E1/G.703 E1/G.703

IFU IFU

KJ
KJ
CJA6 CJA6 KJ

BUS
6AL08
DXS

STM1(4) STM1(4)

ASDH4 ASDH4

12xE1 12xE1

12xE1 12xE1

KJ
KJ
DXS DXS KJ

BUS Mx
2Mb

PBS CJA6 CJA6 PBS



SDH

PBS CJA6 ASDH4 ASDH4 CJA6 PBS



PBS KI

PBS CJA6 CJA6 PBS


SDH

PBS CJA6 ASDH4 ASDH4 CJA6 PBS


ASDH4 ASDH4

PCM30U-OCH
(, , )
PCM30U-OCH 3.




()
TOPONET
DORIS-TopoNet
(discovery, alarms,
DB)

Alarms

Conguravon
Performance
TopoNet SNMP
HP Server / Linux - plaorm
Terminal
Terminal
Terminal
Main Server

Backup Server

TCP/IP DCN network


TOPNET managed systems
S
M PCM30U-OCH
I

S
PCL42-OCH
M
I
Gen. PC

S
Comm.system KONOS
N
M

S

P
N

DCN M
P

Server / Client
TopoNet


(TOPONET)

SNMP


WEB
HW/FW
SMI
o MIB (SNMP )
o WEB


SNMP
PCM30U-OCH
TOPONET

SDH
STM/SFP STM/SFP STM/SFP

STM/SFP

ASDH4 ASDH4


P2 P2

(DIN)
M SMI

PCM30U-OCH ()


SNOM

LAN

ASDH4-1 ASDH4-3 ASDH4-1 ASDH4-3 ASDH4-1 ASDH4-3


ID 10.22.100.102 0 10.22.100.100 10.22.100.101 10.22.100.103 0

C D D C C D D C C D D C

P2 P2 P2 P2 P2 P2
LAN LAN LAN LAN LAN LAN
10.22.100.233/29 0 10.22.3.10/24 10.22.3.36/24 10.22.100.241/29 GW.241 0

SMI SMI SMI


10.22.100.234/29 GW.233 10.22.3.37/24 GW.1 10.22.100.242/29 GW.241

10.22.100.235/29 GW.233 10.22.3.38/24 GW.1 10.22.100.243/29 GW.241



PC notebook (Windows)
LMS-OCH (RS232 Ethernet)
HPX View (USB Ethernet)
NE IP

LMS-OCH / HPX View

RS232
USB
Ethernet
RD
RD -
RD -
RD
RD
RD -
RD -
RD
!

Вам также может понравиться