1.
1.2 , .
1.3 19
1.4 220\50
.
1.5

Flatpack Power System Outdoor 8 kW/20U


:
(TRM) -
GSM/CDMA
(PBX)
()

2.
2.1
2.2
2.3
2.4
2.5 .
2.7 .
3.

, ,
(, ) ,
.

www.eltekvalere.com

Flatpack-2 Power System 8kW 20U Outdoor Cabinet,


.

1.1 M

()

800 x 865

120

20U


- RAL 7035

ST-M,

(120o)

1500,220VAC 50, IP55,

44.

EIA

19 18U

IEC 60950, UL 60950*, CAN CSA-C22.2 No. 60950-1-03

ETSI EN 300 386 V.1.3.1, EN 61000-6-3, EN 61000-6-2

ETS 300 019, Ingress Protection: EN 60529 IP55

341x556x558 (), 300

9 (1*50+1*35+7*25)

(heater)

400, 2 heater

1.3

1.2 : 53 -


580 x 456

4 (10)


(4)

14

www.eltekvalere.com

Type 2 20U Power Cabinet


Air Condition.

Free cooling.


Eltek Valeres Air Condition,


Eltek Valeres Free cooling

(ACU), ,

..

.
,

,

.

2000 BTU/HR
1500 WATTS

2000

EC15HDC1F/230VAC / 58 / IP55

R134a


48 Vdc / 100 / IP44

35 C

44

F5 (EN 779):
- , 0,352
- , 4,22 5,82
- , 4,22
( F5):
, 0,222

9.3 15.4

H x W x D: H x W x D: 20" (508) x 10" (254) x 9.90"


(251)08) x 10" (254) x 9.90" (251)

1100

W x D: 430 x 195

53


( )

UL,


- RAL 7035


( )
,

()

: 1 2

: ,

IEC 60950, UL 60950*, CAN CSA-C22.2 No. 60950-1-03

ETSI EN 300 386 V.1.3.1, EN 61000-6-3, EN 61000-6-2

ETS 300 019, Ingress Protection: EN 60529 IP55

www.eltekvalere.com
Headquarters:
Eltek Valere AS
Grterudveien 8, 3036 Drammen, Norway
Phone: +47-32203200
Fax: +47-32203210

Type 2 Power Cabinet

Cabinet/fan 20U (t=-50)


20

temperature

15
temperature at bottom
temperature in the middle
10

temperature at the top

0
0

500

1000
heat release(Wt)

1500

cabinet/aircondition 20U(t=-50)

23
22,5
22

temperature

21,5
temperature at bottom
21

temperature in the middle


temperature at the top

20,5
20
19,5
19
0

500

1000
heat release(Wt)

1500


50

www.eltekvalere.com
Headquarters:
Eltek Valere AS
Grterudveien 8, 3036 Drammen, Norway
Phone: +47-32203200
Fax: +47-32203210

Cabinet/fan 20U(t=+45)
54
52

heat release(Wt)

50
temperature at bottom

48

temperature in the middle


temperature at the top

46
44
42
40
0

45

500

temperature

1000

1500

Cabinet/aircondition 20U(t=+45)

temperature

40

35

temperature at bottom
temperature in the middle
temperature at the top

30

25

20
0

200

400

600
800
heat release(Wt)

1000

1200


45

www.eltekvalere.com
Headquarters:
Eltek Valere AS
Grterudveien 8, 3036 Drammen, Norway
Phone: +47-32203200
Fax: +47-32203210

200

Cabinet/fan 20U(t=+45)

180

power (Wt\h))

160
140
120

power (Wt\h)

100
80
60
40
0

1600

500

1000
heat release(Wt)

1500

Cabinet/aircondition 20U(t=+45)

1500
1400

power (Wt\h)

1300
1200
power (Wt\h)

1100
1000
900
800
700
0

200

400

600
800
heat release(Wt)

1000

1200


45

www.eltekvalere.com
Headquarters:
Eltek Valere AS
Grterudveien 8, 3036 Drammen, Norway
Phone: +47-32203200
Fax: +47-32203210

Cabinet/fan 20U(t=-50)
1050
950
850

power (Wt\h)

750
650

power (Wt\h)

550
450
350
250
150
0

1550

500

1000
heat release(Wt)

1500

Cabinet/aircondition 20U(t=-50)

1350

power (Wt\h)

1150
950
power (Wt\h)
750
550
350
150
0

500

1000
heat release(Wt)

1500


50

www.eltekvalere.com
Headquarters:
Eltek Valere AS
Grterudveien 8, 3036 Drammen, Norway
Phone: +47-32203200
Fax: +47-32203210

Cabinet 20U
35
30

Temperature

25
20
temperature at bottom
15

temperature in the middle


temperature at the top

10
5
0
0

50

100

150

200

250

Time (min)


40

www.eltekvalere.com
Headquarters: