JIF-15A

USER MANUAL
CONTENTS
Safety Notification ……...……..……..………….……….…….……………………………..………..…...2
Feature Introduction …...……..……..………….……….…….……………………………..………..…...3
Chapter 1 Specification …....………...……………………….………………………………………....…4
Chapter 2 Front Panel Specification ……,………………….………………………………………….5~6
Chapter 3 Display size .…..……....……..………………….……………………………………………...7
Chapter 4 Function parameter setting description ….....……………………………….…………..8~13
4-1 GEF Function Parameter Description …..……….…………………………….……………8~9
4-2 RSF Function Parameter Description .....………………...................................……….10~11
4-3 SQ RSF Function Parameter Description ………………………………….…………….12~13
Chapter 5 Calibration parameter setting and process ....……………………………….…………14~23
5-1 Calibration.……………………………………………………..………….................................14
5-1.1 01 CSP Specification setting description .....…………......................................15~17
5-1.2 02 CAL Normal calibration description ………………….………………………….....18
5-1.3 Calibration error message ...….…..……………………….……………………………18
5-1.4 03 CLN Linear Calibration Description ….….…………….………...…………………19
5-1.5 04 CV Digital Calibration Description …………………….……………………………20
5-2 Self-test mode …………………….….…………….………………………………….…........21
5-3 INIT Resume factory setting ...…….……. ……….…………….…………………………….22
5-4 MOD Use monitor as the remote display …..…….………………………………………….23
RS-232 & RS-485 serial output / input interface (build-in) ….…………………………………….24~27
Analog current output interface (OP-02) ………………………………………………………………..28
External signal output / input interface (OP-03) ……………………………………………………29~30
Check Weighing Configuration …..………………... ……………………………………………………31
Chapter 6 Maintenance ……………………….………... ………..………….………………...………...32
Calculation signal output condition …..…………. …………………………………………………..….33
Normal load calculation ..….…………..…………. …………………………………………………..….34
Normal unload calculation ……... .…..…………………………………………………………………...35
Normal compare mode ....………..…..…………………………………………………………………...36
Normal Batching (Built-in Program) ..………………………………...…….……………………………37
Loss-in Weight(Built-in Program) …...……………………………………………………………………38
Attachment 一 APPENDIX I DESCRIPTION OF 7 SEGMENT CHARACTERS .............................39
Attachment 二 MODBUS Data Registers ….……………………..….…………………………………40

1
Safety Notification

 Shut down the power source before assembly/disassembly.

 Do not use directly under sun ray. The ideal operation temperature is -10℃
℃ ~ +40℃

 Grounding is strictly required (grounding impedance <100Ω


Ω). Do not share grounding
with other facility needing excess power.
Missing or wrongful grounding may cause electric shock or malfunctioning.

 The facility applies AC 100V ~ 240V

 When using high resolution scales to weight, the brass net and sensor should be
grounded at assembling the sensor

2
Feature Introduction
JIF-15A Weight
GW-2000 WeightDisplay
DisplayController
Controller
is is
measurement
measurementtool
tool
with
with
high
high
precision
precision and
and
r resolution.
It can display up to six digits and provide multiple control interfaces. It is a robust, powerful
and delicately designed controller for measuring weight. The features include:

 Compact Design
 Standardized dimension of 96×48 mm makes it easy to be embedded on a distribution
power panel or mechanical facilities.
 High performance CPU and A/D Interface
 Apply 32Bits CPU
 0.12µVD high sensitivity and resolution
 Sampling speed: 120 times/second
 Measurement range -0.1 ~ 39 mV

 Intellectual Calibration
 Normal 2 points calibration
 5 points of linear calibration

 Multiple adjustable digits wave filter


It can effectively restrain the surrounding vibration
 Multiple weight control modes cover most of the application
 Flexible calculation modes can complete calculation control process
independently, as well as be connected to PLC to link to complicate
interaction between system, machine, and operator
 Auto replenish
 Manual/auto evacuate waste material
 Adjustable batch number
 Weight and accumulation
 A set of built-in full-duplex RS232C, or semi-duplex RS485 serial interface
 Built-in bi-directional ASCΙΙ and MODBUS RTU
 Application:
 Mechanic weight for package calculation
 Barrel and trough weight management system for chemical factory, and truck scale
management system
 Various product weight filtering control, and pull-push test equipment control
3
Chapter 1 Specification
A/D Specification
♦ Weight stimulated power: DC 5V ±5% , 120mA (with maximum 8 350 Ω weights)
♦ Maximum measured voltage: -1mV ~ 39mV
♦ Input sensitivity: Above: 0.12µV/D
♦ Transfer velocity: about 120 times/ sec (max.)
♦ A/D resolution: Applies△Σ, and the internal resolution is 1/1,000,000
Digital display specification
♦ Primary display: 6digits, 7 red levels display, font height is 0.56˝
♦ Display indication:4 red 3ψ LEDs
♦ Display refresh rate: 50 times/sec
♦ Display range: - 199999 to 999999
♦ Minimum weight scale: 1、2、5、10、20、50
♦ Decimal point: 0、0.0、0.00、0.000
♦ Memory: Calibration parameter and function settings are stored at EEPROM

Optional adaptor
♦ OP-01 RS232 / RS485 /BT
♦ OP-02 16 Bits Analog Electric current output interface (0 ~ 20 mA、0~10V)
♦ OP-03 Control I/O(8I/8O)

Power
♦ Single phase AC voltage 100V ~ 240V or DC voltage 12~24V
♦ Power consumption 5 VA

Others
♦ Operation temperature: -10℃ ~ 40℃ , < 85% RH
♦ Dimension:(mm) 96(W) × 48(H) × 43.5(D)
♦ Weight about 0.2 kg

4
Chapter 2 Front Panel Specification

◎ Panel display description


1: Primary display
◆ Red 6 digits, net/gross weights are displayed at 0.56”
2: Status LED indication
◆ MD : Weight instability indication light
◆ ZERO : zero gross weight indication light
◆ NET: Net weight indication light
◆ GROSS: Gross weight indication light

◎ Panel button description

ESC Key ◆ On / Standby switch

Hold 6 seconds to enter Standby mode


Press to switch from Standby mode to Normal mode
◆ “Cancel” at functional and parameter setting

ZERO Key ◆ Set zero


◆ “Move Left” at functional and parameter setting

TARE key ◆ Tare weight


◆ “Move Right” at functional and parameter setting

5
F1 key ◆ “Increase” at functional and parameter setting

FUNC key ◆ Set weight parameter

◆ “Decrease” at functional and parameter setting

ENTER key ◆ “Confirm” at functional and parameter setting

Special complex function

◆ Hold and to enter build-in function parameter setting (to set 01-GEF, 02-RSF,03-SQ)

◆ Hold and to enter optional parameter setting


(to set OP-01,OP-02,OP-03,OP-04,OP-05,OP-06)

◆ Hold and to enter calibration, self-test mode, and resume factory setting
(01-CSP,02-CAL,03-CLN,04-CV,05-TES,06-INI,07-MOD)

6
Chapter 3 Display size

7
Chapter 4 Function parameter setting description
4-1 GEF Function Parameter Description

Item Function Parameter Setting Description Default

0﹕120 times/Sec
1﹕100 times/Sec
2﹕ 80 times/Sec
3﹕ 65 times/Sec
A/D Sampling 4﹕ 25 times/Sec
GEF-01 4
Frequency 5﹕ 12 times/Sec
6﹕ 6 times/Sec
7﹕ 3 times/Sec
8﹕ 2 times/Sec
9﹕ 1 times/Sec
0 NA
1 Weak
2
Digital Filter I
GEF-02 2
I 3

4
Strong
5

GEF-03 Digital Filter II 0~9 3

Parameter ⇒ Description
0 ⇒ Switch Net Weight/ Gross Weight
1 ⇒ Weight comparison parameter
GEF-04 Set “FUNC” key function 1
setting
2 ⇒ Clear tare value
3 ⇒ Manual communication
4 ⇒ Start calculate
5 ⇒ Stop calculate
6 ⇒ Start weight comparison
7 ⇒ Evacuate material
GEF-05 Set “F1” key function 8 ⇒ Accumulate weight and times 0
9 ⇒ Clear accumulated weight and times
12 ⇒ Gross / Net / Accu V/ Accu C

8
Setting
Item Function Default
Parameter Description
Front panel “ZERO” Parameter ⇒ Description
light 0 ⇒ Zero
GEF-06 0
Display status setting 1 ⇒ MD
(First) 2 ⇒ Gross
3 ⇒ Net
Front panel “MD” light
4 ⇒ Accu. V
GEF-07 Display status setting 1
5 ⇒ Accu. C
(Second)
6 ⇒ SP1
Front panel “GROSS” 7 ⇒ SP2
light 8 ⇒ SP3
GEF-08 2
Display status setting 9 ⇒ Hi
(Third) 10 ⇒ OK
11 ⇒ Lo
12 ⇒ Under
Front panel “NET” light 13 ⇒ Over
3
GEF-09 Display status setting 14 ⇒ Unloading
(Four) 15 ⇒ Running
16 ⇒ Hold

0
Normal hold
Hold
GEF-11 0
Keep the function 1 Peak hold

0 No limit
1 20 times/sec
Rate for display rewrite
GEF-12 2 10 times/sec 0
3 5 times/sec
4 1 times/sec
Normal Correspo
000000 0 (lock disable) nding to
Key – Locked
GEF-13 ↓ keys in 000000
111111 Close front
1 (lock enable)
panel

9
4-2 RSF Function Parameter Description

Function Description Default


Item Parameter
0 As displayed
1 Gross

RSF- 01 2 Net
Transmission 0
format 3 As displayed (simple)

4 Gross(simple)

5 Net(simple)
6 Comparison status + As displayed (simple)
0 Continuous transmitting + command mode

1 Auto transmitting + command mode


RSF- 02 3
2 Manual transmitting + command mode
Transfer mode
3 Command mode

4 MODBUS RTU mode


600
1200
2400
4800
9600
RSF- 03 19200
Transmission 38400 9600
speed
57600
76800
115200

N、8、1 No parity, 8 digits, 1 stop parity


RSF- 04
O、7、1 Odd parity, 7 digits、1 stop parity
Communications E、7、1
protocol E、7、1 Even parity, 7 digits、1 stop parity
N、8、2 No parity、8 digits、2 stop parity

10
0 No limit
1 1 times/sec
RSF- 05
Transmission 2 2 times/sec
0
times 3 5 times/sec
4 10 times/sec

0 ⇒ Continue
000000
RSF- 06 transmission
Transmission
000000
1 ⇒ Stop transmission Weight unstable
conditions Overload(OL)

RSF- 07 00~99 00 stands for not applying address 0


address

11
4-3 SQ RSF Function Parameter Description

Setting
Item Function Default
Parameter Description
1 Normal input calculation
2 Normal evacuate calculation
3 Normal compare mode
Compare Mode
SQ- 01 4 build-in programmed input calculation 1
build-in programmed evacuate
5
calculation

Calculation start signal input. After


Start Delay Time 0.0 ~ 25.5 consuming set delay time, build-in
SQ- 02 0.0
(sec) program will start weight comparison
program.
No input material comparison will be
SP2,SP3 0.0 ~ 25.5 made within this set time range.
SQ- 03 0.0
Compare wait time (sec) If setting to 0 (zero), it means no
application for this function.
Calculation completion
0.0 ~ 25.5 After consuming set delay time, output
SQ- 04 signal output 0.5
(sec) calculation completion signal.
Delay time
0 Waiting for weight stabilization
Calculation completion
SQ- 05 No need to waiting for weight 0
signal output status 1
stabilization
The period for maintaining calculation
Calculation completion
0.0 ~ 25.5 completion signal output.
SQ- 06 signal output 1.0
(sec) Setting to 0 (zero) means not to clear
Maintain time
this result until next calculation starts

Compensation Count Setting to 0 (zero) means not to apply


SQ- 07 0 ~ 255 0
this function.
Comp. Open Valve
0.0 ~ 25.5 Need to match up compensation time
SQ- 08 Time 0.1
(sec) (SQ-07)

Comp. Close Valve


0.0 ~ 25.5 Need to match up compensation time
SQ- 09 Time 1.0
(sec) (SQ-07)

12
Setting
Item Function Default
Parameter Description
Start Automatic
0.0 ~ 25.5 Discharge signal is ON when reaching
SQ- 10 discharge 0.0
(sec) delay time.
Delay time
Turn of discharge 0.0 ~ 25.5 Discharge signal is OFF when reaching
SQ- 11 0.0
signal Delay time (sec) delay time.

0 ~ 255 Setting to 0 (zero) means not to apply this


SQ- 12 Discharge time 0
(sec) discharge control function

Restart signal is ON when reaching delay


Delay time to 0.0 ~ 25.5
SQ- 13 time. 1.0
“Restart” (sec)

Batching Count 0 ~ 255 Calculation loop count


SQ- 14 0
(sec) 0 ⇒ Unlimited
Set zero point as 0 Not set
weight completion
SQ- 15 0
value 1 Set

0 Compare anytime
1 Compare after completing calculation
Hi、OK、Lo Compare when there is external input
2
SQ- 16 Action judgment signal 0
Compare when calculation is completed
3
and there is external input judgment signal
4 Automatic compare
Automatic 0 Turn off
SQ- 17 accumulate 0
1 Turn off
weight/time
Source of weight 0 Input from front panel
SQ- 18 0
compare parameter 1 Input from rear panel
weight comparison
0.0 ~ 25.5
SQ- 19 (Judgment) Hi、OK、Lo weight comparison delay time 0.5
(sec)
delay time
0 press Tare key to tare weight
SQ- 20 Automatic tare 0
1 Automatic tare weight
0 Trigger from external or key
SQ- 21 Automatic discharge 0
1 automatic discharge + manual

13
Chapter 5 Calibration parameter setting and process

5-1 Calibration process Hold and

01 CSP 02 CAL 03 CLN 04 CV 05 TES 06 INI


Specification normal linear voltage test mode restore
setting calibration calibration calibration

0 DSP INT-FN
CSP- 01 1P NO ZERO
1 KEY INTALL
CSP- 02 ZERO 2P NO 0.00000
2 ADC INT-ZO
CSP- 03 3P NO SPAN
3 UAR1
CSP- 04 SPAN 4P NO 2.00000
4 UAR2
CSP- 05 5P NO CAP
5 DA
CSP- 06 020000
6 PNT
CSP- 07
7 EEP
CSP- 08
8 I-O
CSP- 09
Use up, down, left
and right keys to
CSP- 10
choose desired
function
CSP- 11
ESC is to exit

ENTER is to confirm

14
5-1.1 Specification setting description

01 - CSP
* Calibration Parameter Description
Press key

CSP - 01 【Unit】
CSP - 01

Key in calibration parameter CSP - 02 【Decimal】


code to be set
CSP - 03 【Minimum scale】
CSP - 05
CSP - 04 【Maximum weight】
Press key
CSP - 05 【Valid set zero range】
000000

Monitor will display previous CSP - 06 【zero point track time】


parameter.
Key in parameter to be set, CSP - 07 【zero point track range】

and press key


CSP - 08 【Stable detection time】
CSP - 06
CSP - 09 【Stable detection range】

CSP - 10 【set zero and tare when


weight is not stable】

You can continue to set other functions,


CSP - 11 【Tare when gross weight
is negative】
or press key to exit

15
Setting
Item Function Default
Parameter Description
0 NA
1 g
CSP-01 Unit 2 kg 2
3 t
4 lb
0 NA
1 decimal point one
CSP-02 Decimal 0
2 decimal point two
3 decimal point three
1
2
5
CSP-03 Minimum scale Minimum scare to display weight 1
10
20
50
999999
Maximum Maximum weight to be displayed
CSP-04 ↓ 999999
weight
000000
0 ⇒ full range
Valid set zero 1 ~ 30 ⇒ ±1% ~ ±30%
CSP-05 0 ~ 30 0
range Valid set zero range=calibration zero
point±(Maximum weight × setting%)
Zero point track time needs to be applied
zero point 0.0 ~ 5.0
CSP-06 with zero point track range,Setting to 0.0 will 1.0
track time (sec)
turn off the zero point track time
Zero point track range=(Setting×½)D,
D=minimum scale,
zero point
CSP-07 0~9 Zero point track time needs to be applied 2
track range
with zero point track range, Setting to 0 will
turn off the zero point track function
Stable detection time needs to be applied
Stable 0.0 ~ 5.0
CSP-08 with stable detection range, 1.0
detection time (sec)
Setting to 0.0 will turn off the stable detection
Stable detection time needs to be applied
Stable detection with stable detection range,
CSP-09 0~9 2
range Setting to 0 will turn off the stable detection

16
set zero and 0 Active
tare when
CSP-10 0
weight is not 1 Not Active
stable
Tare when 0 Active
CSP-11 gross weight is 0
1 Not Active
negative

17
5-1.2 Normal calibration description
Choose
ZERO

Zero point calibration


Confirm there’s nothing on the weighting platform or barrel.

------ Under zero point calibration

SPAN

Press key

030000

Weight calibration
Put a sample that is known by its weight on the weight platform or barrel, and key in the weight
by the front panel. After system is stabilized

------ SPAN under calibration

Countdown will be displayed after calibration

5-1.3 Calibration error message


. ⇒ Load Cell output voltage < - 0.1mV/V or > 4mV/V

. ⇒ Weight setting ≤ previous setting

. ⇒ Measured weight ≤ previous figure

. ⇒ Setting is 0

. ⇒ mV/V setting > measurement range

. ⇒ mV/V setting is too small ( SPAN – Zero < 0 mV/V )

. ⇒ Calibration resolution exceeds 0.12µVD

18
5-1.4 Linear Calibration Description

1P NO

Press key

001566

When LED flicks, weight is displayed

Press key

001600

Key in correct weight, and press key

2P NO

5P NO

Follow this procedure to implement calibration. After completion, press key to exit.

Use up, down, left, and


right keys to key in figure

Press ESC to exit

Press ENTER to confirm

19
5-1.5 Digital Calibration Description

04 CV
Method 一 key in zero point
press keys voltage mV/V press key

Method 二

ZERO 0.00000 auto zero point calibration press key


keep weight platform clean

0.00000 display zero point


voltage mV/V

key in cross range


SPAN 0.00000 press key
voltage mV/V

key in cross press key


CAP 000000
range weight

20
5-2 Self-test mode

Hold and keys to enter self-test mode and resume factory setting

Test mode (05-TEST)


Item Display Test item

0 7 modes of display and LED indication test

1 Keyboard test

2 AD internal value display test

Build-in RS-232 serial input/output


3
interface

4 RS-232 serial input/output interface

5 OP-02 Analog current input/output interface

6 Under construction

7 EEPROM Memory test

8 Control I/O interface test

21
5-3 INIT Resume factory setting

Hold and keys to select

Set the function parameter setting as factory default

1 FUNC Hold Enter for 3 seconds until PASS is displayed

Clear zero point compensation value

2 ZERO Hold Enter for 3 seconds until PASS is displayed

Restore all parameter setting as factory default

3 ALL Hold Enter for 3 seconds until PASS is displayed

Description: Choose the desired option, and then hold the key until PASS is displayed.
This indicates the successful restoration. If you want to cancel this action,
just release the key.

22
5-4 MOD Use monitor as the remote display

Hold and keys choose

07 MOD MOD_01 000000

press key press key

Setting Function description Remark


0 Used as Weight controller (factory setting) Refer to GW-2000
1 Used as remote display to receive/transmit two-way ASCII Refer to **1
2 Used as remote display to receive/transmit two-way Modbus RT You can set GW-2000

**1
Receive ASCΙΙ

Net S T , G S , + 0 1 2 3 4 5 6 k g
Gross S T , N T , + 1 2 3 4 . 5 6 g
Tare S T , T R , + 0 1 2 3 4 5 6 t
Positive
O L , G S , + SP SP SP SP SP SP SP SP SP CR LF
overload
Negative
O L , G S , - SP SP SP SP SP SP SP SP SP
overload
Unstable U S , G S , + 1 2 3 4 . 5 6 k g
Transmit ASCΙΙ

Zero:MZ Tare: MT Tare reset: CT

07 MOD MOD_02 000000

Press key press key

Setting Function description Remark


0 Receive USART2 communication mode I
1 Receive USART2 communication mode I I Optimized UART setting is
2 Receive USART2 communication mode I I I MOD-02

23
RS-232 & RS-485 serial output/input

interface(build-in)

PIN Function
4 TXD / DA +
5 RXD / DA -
6 SG

RS-232/RS-485 transmission data description

1. Normal format
Net S T , G S , + 0 1 2 3 4 5 6 k g
Gross S T , N T , + 1 2 3 4 . 5 6 g
Tare S T , T R , + 0 1 2 3 4 5 6 t
Positive
O L , G S , + SP SP SP SP SP SP SP SP SP CR LF
overload
Negative
O L , G S , - SP SP SP SP SP SP SP SP SP
overload
Unstable U S , G S , + 1 2 3 4 . 5 6 k g

2. Simple format
GW/NW or both + 1 2 3 4 5 6 7
Positive overload + SP SP SP SP SP SP SP CR LF
Negative overload - SP SP SP SP SP SP SP

3. Compare status (1) + simple mode (GW/NW or both)


+ 1 2 3 4 5 6 CR LF

bit 7 bit 6 bit 5 bit 4 bit 3 bit 2 bit 1 bit 0

bit 0 : Zero Band


bit 1 : Over
bit 2 : Under / Hi
bit 3 : SP1 / Go
bit 4 : SP2 / Lo
bit 5 : SP3
bit 6 : Unloading
bit 7 : Batch finish

24
RS-485 / 232 command format table
1. Command format A
Host Command
Slave Command

MZ set zero CZ clear zero point compensation value


MT tare weight CT clear tare weight
MG display GW MN display NW
AT accumulate current weight and plus one time
ST deduct previous accumulated value and minus one time
DT clear accumulated value and time
BB star calculation (single time) HB stop calculation
BD start evacuation
SC Set as continuous transmission mode SA Set as auto transmission mode
SM Set as manual transmission mode SO Set as command mode
% Stop continuous transmission mode and enter command mode

2. Command format B
Host Command
Slave Data

RW Read current weight RT read tare weight


RG read GW RN read NW
RB Read current weight (simple) RH read GW (simple)
RI read NW (simple)
RJ read compare status + current weight (simple)
RK read compare status + GW (simple)
RL read compare status + NW (simple)
RO Read compare status(二)
RF Read previous completed weight value RA read accumulated value (including counts)
Note : add % in front of a command can proceed with continuous reading
Read weight compare setting RS□□ □□ : setting item
FW read following target setting S1 read SP1 setting
S2 read SP2 setting S3 read SP3 setting
UD Read Under setting LO read LO setting
ZB Read Zero Band setting HI read HI setting
Read peak condition setting Read peak
PR condition setting OV read OVER setting

Example: Command : RSFW<CR><LF> EX:GW2000 Ans : RSFW□□□□□□

25
3. Command format C

Host Command + Data


Slave Command + Data

Write weight compare setting WS□□XXXXXX


□□ :Setting Item XXXXXX :Setting value(6 bytes)
FW Write supply material target setting S1 Write SP1 setting
S2 Write SP2 setting S3 Write SP3 setting
UD Write Under setting LO Write LO setting
ZB Write Zero Band setting HI Write HI setting
PR Write peak condition setting OV Write OVER setting
BC Write SQ14 setting PT Write OUT setting
(key in 0-255 decimal)
Note: WSPTxxxxxx( )transfers BIT value to showOUT(1 – 8)
ON,OFFstatus
Example: key in WSPT000010 means BIT value = 00001010 (OUT 2,4 = ON)
(OUT1,3,5,6,7,8 = OFF)

 Error message
E1:command format error
E2:set parameter is out of range
E3:condition mismatch

 Addressing mode
When RSF-07 address is set as 0, local machine will execute the command after receiving
command.
When RSF-07 address is set as 1~99, local machine will compare the address in front of the
command, and execute command after confirming correctness,
For example: If the host would like to read the current weight of address #2 GW-2000, it can
send the command @02RW<CR><LF>

Final Wt

26
RS-485 Connection figure

Transmission Line:
Twisted pair with outer mask covered is necessary, The quality of transmission line impacts the
signal a lot. Twisted pair with poor quality will cause great lose of signals transmitted at high speed.
The transmission distance will also be greatly decreased, and the ability of anti-noise is lower. So,
please apply high quality twisted pair when it comes to the high transmission speed, long distance,
or heavy noise.

Terminal impedance:
Each signal transmission circuit has it ‘s own characterized impedance. When the signal is
transmitted to the terminal through transmission line, if the terminal impedance is different from the
characterized impedance, reflection will be made and thus result in distortion of the signal wave.
The distortion is not obvious at a short distance, however, with the increasing length of transmission
line, distortion will get more obvious. Under this circumstance, the intermediate impedance is
needed. (Terminal impedance is about 120Ω)

27
Analog current output interface (OP-02)

Hold and keys to enter optional parameter setting OP-2

PIN Function
C1 Common point
X0 IN PUT (set zero)
V+ Voltage output
A+ Current output

Item Function Setting Default


Parameter Description
0 as displayed
02- 01 data mode 1 Gross 0
2 Net

02- 02 output signal 0 Current output 0

02- 03 low weight 000000 ~ 999999 When the weight reaches the set 0
value of AnL-03, current/voltage
02- 04 low current 0.0 mA ~ 20.0 mA output will be the set value of AnL-04 4.0

02- 05 high weigh 000000 ~ 999999 When the weight reaches the set 30000
value of AnL-05, current/voltage
02- 06 high current 0.0 Ma ~ 20.0 Ma output will be the set value of AnL-06 20.0

DA zero point Adjust DA analog output zero point


02-07 A0.000
fine-tune value.
DA SPAN Adjust DA analog output SPAN
02-08 A0.000
fine-tune value.

28
External signal output/input interface (OP-03)

Hold and keys to enter optional parameter setting OP3-IN

Item Function Setting Default


Parameter ⇒ Description

IN - 01 Input 1(X0) 0 ⇒ NA 1
1 ⇒ Zero
IN - 02 Input 2(X1) 2 ⇒ Tare 2
3 ⇒ Tare reset
IN - 03 Input 3(X2) 4 ⇒ Start (L 3
5 ⇒ Stop (L)
IN - 04 Input 4(X3) 6 ⇒ Unload Command 4
7 ⇒ Hold
IN - 05 Input 5(X4) 8 ⇒ Hold display & I/O reset 5
9 ⇒ Accu. Command
IN - 06 Input 6(X5) 10 ⇒ Accu. Clear 6
11 ⇒ Clear previous accumulated value
IN - 07 Input 7(X6) 12 ⇒ Judgment start weight compare 7
13 ⇒ Print manual output streaming and serial data
IN - 08 Input 8(X7) 14 ⇒ Net/Gross 8

29
Hold and keys to enter optional parameter setting OP3-OU

Setting
Item Function Default
Parameter ⇒ Description

OUT- 01 Output 1 1
0 ⇒ NA
OUT- 02 Output 2 1 ⇒ Zero band 2
2 ⇒ SP1
3 ⇒ SP2
OUT- 03 Output 3 4 ⇒ SP3 3
5 ⇒ Batch finish
6 ⇒ Unloading
OUT- 04 Output 4 7 ⇒ Peak ready 4
8 ⇒ Stable
9 ⇒ Internal batching process running
OUT- 05 Output 5 10 ⇒ Under 5
11 ⇒ Over
12 ⇒ Hi
OUT- 06 Output 6 13 ⇒ OK 6
14 ⇒ Lo
15 ⇒ Hi Hi
OUT- 07 Output 7 16 ⇒ Lo Lo 7
17 ⇒ Final

OUT- 08 Output 8 8

The output logic of 0000 ⇒ positive Logic


OUT- 09 0000
OUT-04~OUT-01 1111 ⇒ negative Logic
The output logic of 0000 ⇒ positive Logic
OUT- 10 0000
OUT-08~OUT-05 1111 ⇒ negative Logic

30
Check Weighing Configuration

Under normal status, Final

Press key

Display previous set Undervalue,


Display previous set Final value Key in data as requested,Press
Key in data as requested, key
SP1 Z.Band
Press key

Display previous set SP1 value, Display previous set Zero Band,
Key in data as requested,, Key in data as requested,Press
SP2 key
press key Final

Display previous set SP2 value,


Key in data as requested,
SP3
press key


Display previous set SP3 value,
Key in data as requested,
Over
press key

Display previous set Over value,


Key in data as requested,

press key Under

31
Chapter 6 Maintenance

◆Under normal status, press and keys,simultaneously to enter function parameter

setting screen.
Select 05.TEST to enter detection mode.
◆ DSPDetection
7 level display and LEDs will all light up for 1 second, and all off for 1 second.
Then, 7 level display will display 0~9 and . separately with interval of 1 second. Led will light up
from left hand side to right hand side.
◆ KEY Detection
Turn calibration switch and press keys at front panel. The relative bits should display from i -> I.
◆ ADC Detection
Display range: n0~524287(-1mV ~ 39mV)
◆ UART1 Detection
System send out ASCII 0~9
◆ UART2 Detection
ASCII 0~9。 System send out ASCII 0~9
◆ DA Detection
Press Up or Down to switch between DA output value, 0:LO (zero point value) and 1:HI (full load
value)
◆ PNT Detection (under construction)
◆ EEP Detection
PASS means normal, and FAIL means malfunctioning.
◆ INPUT/OUTPUT Detection
Input port signal ON/OFF corresponds the display digits as i -> I

Press Up or Down to switch output single port ON/OFF

32
Calculation signal output condition
★ Load calculation signal output condition
Signal Output condition
SP1 Net ≥ Final - SP1
SP2 Net ≥ Final - SP2
SP3 Net ≥ Final - F.Fall
Under Net < Final - Under
Over Net > Final + Over
Zero Band Gross ≤ Zero Band

★★ Unload calculation signal output condition


Signal Output condition
SP1 Gross ≥ SP1
SP2 - Net ≥ Final - SP2
SP3 - Net ≥ Final - F.Fall
Under - Net < Final - Under
Over - Net > Final + Over
Zero Band Gross ≤ Zero Band

33
Normal load calculation
Start

tare weight

Net ≥ Final - SP1

SP1 output

Net ≥ Final – SP2


SP2

SP2 output Signal Output status Out Put LED

SP1 NET ≥ Final-SP1 ON ON


Net ≥ Final – SP3
SP3 SP2 NET ≥ Final-SP2 ON ON
SP3 NET ≥ Final-SP3 ON ON
Zero.Band GR0SS≤ Zero.Band ON ON
SP3 output

Stability judgment
<SQ05>

Output delay time


Setting<SQ04>

Reaching output delay


Closed batch finish signal
time

Calculation completion indicator is on Finish

Calculation completion indicator maintaining


time setting<SQ06>

Reaching calculation
completion maintaining
time
34
Normal unload calculation
Start

Check supplying hopper


enough for this batch of loading

Batch start

SP1 gate open

Tare

NET ≥ Finall-SP2

SP2 gate output


Signal Output status Out Put LED

NET ≥ Finall-SP3 SP1 GROSS ≤ SP1 ON ON


SP2 NET ≥ Final-SP2 ON ON
SP3 NET ≥ Final-SP3 ON ON
SP3 gate output
Zero.Band GR0SS≤ Zero.Band ON ON

Batch finish condition,


stabilized or not <SQ05>

Output delay time


Setting <SQ04>
Reaching calculation completion
maintaining time
Reaching output delay
time
Closed batch finish signal

Calculation completion indicator output


Finish

Calculation completion indicator


maintaining time setting <SQ06>
35
Normal compare mode

Dynamic auto compare after trigger signal calculation


compare compare calculation compare signal competed
signal completed mode + trigger signal

NET < LO NET>Z.Band calculation trigger calculation


LO output compare signal signal signal competed
output delay time + trigger signal

≤ NET<HI
LO≤ weight reaching delay calculation calculation
OK output stabilized time compare compare
signal output signal output
delay time delay time

NET ≥ HI NET < LO NET < LO reaching delay reaching


HI output LO output LO output time delay time

≤ NET<HI
LO≤ ≤ NET<HI
LO≤ NET < LO NET < LO
OK output OK output LO output LO output

NET ≥ HI NET ≥ HI ≤ NET<HI


LO≤ ≤ NET<HI
LO≤
HI output HI output OK output OK output

NET ≥ HI NET ≥ HI
HI output HI output

36
Normal Batching (Built-in Program)

Start B C
A

N Batch finish SQ5 = 1


N
Waiting time
condition, not stabilized ZERO BAND
Start batch comparison signal output ON
start( SQ3 ) stabilized or
Signal input not (SQ5)

Y SQ5 = 0
SQ14 = 0 Y
Y stabilized
Unloading SQ14 = 1
Unloading unloading
SQ20 = 0 N N continuously
continuously
TARE auto Tare manual Waiting control once
open Comparison delay W eight stabilized control
(SQ20) ( SQ14 )
time arrived SQ14 = 2~255
Unloading
SQ20 = 1 continuously
TARE auto Y
control

N Batch finish Unloading times Y


TARE
NET ≧ output signal arrived
Final-SP3
N
Start batch Batch finish
signal delay
Y output signal Unloading
time start control - to
time (SQ2)
activate delay
SP3 output ( SQ6 )
time start
OFF ( SQ13)

SQ21 = 0
N Discharge
Doscharge
Start batch delay Batch finish setting auto manual C
time arrived output signal ( SQ21 ) Unloading control -
delay time to activate delay
start(SQ4) SQ21 = 1 Discharge time arrived
auto
Y
To activate
SP1 , SP2 , discharge on
N delay time
SP3 output ON Reach batch finish ( SQ10 ) start over
output signal delay time

N Y N
NET ≧ SQ7 = 0 not
Discharge delay
To activate supplementar
Final-SP1 supplementar time arrived.
y loading
y loading B
( SQ7 )
Y SQ7 = 1 ~ 255 Y
supplementary
open
SP1 output Discharge signal
OFF output ON
NET < UNDER

Waiting time To activate


comparison discharge tim e
( SQ3 ) ( SQ12 )
Time of
Supplementar
y gate open
N
(SQ8 )
N
To reach waiting Discharge time N ZERO BAND
time comparison SP3 signal arrived signal output ON
output ON
N Y
Y Y
N To activate
NET ≧ Supplementary N discharge of
Final-SP2 loading gate open NET < UNDER delay time
( SQ11 )
arrived
N
Y Y Y
SP2 output SP3 signal Discharge of delay N ZERO BAND
OFF output OFF time arrived signal output ON

Y
A Supplementar Y
y loading gate
closed time Discharge signal
start( SQ9 ) output OFF

N
Time of C
supplementary
loading gate arrived

N To reach times of Y
supplementary B
loading

37
Loss-in Weight(Built-in Program)

S ta r t A B

SQ 15 = 0
Z e ro B a n d n o t s e tt in g W a itin g B a tc h fin is h SQ 5 = 1
< = F in a l W t. c o m p a r is o n n o t s ta b iliz e d
(S Q 1 5 設 定 ) o u tp u t i s
d e a l y tim e s ta b iliz e d o r
s ta rt( S Q 3 ) n ot (S Q 5)
S Q 1 5 = 1 s e ttin g
Y SQ 5 = 0
S ta b iliz e d
N S u p p ly in g b i n w e ig h t C h e c k s u p p ly in g b in is
N
is r e a c h in g z e r o r a n g e e n o u g h f o r n e x t b a tc h W a it in g
or not o f u n lo a d in g W e ig h t s ta b iliz e d
c o m p a ris o n d e la y or not
tim e a r riv e d
Y
Y
Y
S u p p ly in g b in N
g a te o p e n N B a tc h fin i s h
-N E T ≧ s ig n a l o u tp u t
F in a l-F .F a ll
N
B a tc h fin is h
G R O SS≧ SP1 Y o u tp u t s ig n a l
tim e s ta rt
S P 3 o u tp u t ( SQ6 )
Y O FF
SQ 14 = 0
U n l o a d in g S Q 14 = 1
c o n tin u o u s ly U n lo a d in g U n lo a d in g
S P 1 o u tp u t B a tc h f in is h , c o n tr o l c o n tin u o u sl y s in g le
s ig n a l o u tp u t c o n tro l
d e la y tim e ( SQ 14 )
sta r t(S Q 4 ) S Q 14 = 2~255
U n lo a d in g
S u p p ly in g b in c o n tin u o u s ly
c o n tro l
g a te c lo s e d
N T o re a c h u n lo a d in g
B a tc h fin is h , s ig n a l
o u tp u t d e la y tim e
tim e s
N a r riv e d

B a tc h s ta r t s ig n a l Y
in p u t Y
SQ 7 = 0 not U n lo a d in g
T o a c tiv a te s u p p le m e n ta r c o n tr o l - to
s u p p le m e n t a r a c tiv e d e a ly
y lo a d in g
y lo a d in g B tim e s ta rt
Y ( SQ7 ) ( SQ 13 )
SQ 20 = 0 SQ 7 = 1 ~ 255
T o a c tiv a te TARE T o a c tiv a te
TAR E m anual s u p p le m e n ta ry
f u n c tio n lo a d in g
(S Q 2 0 ) U n lo a d in g c o n tro l -
SQ 20 = 1 N ET < UNDER to a c tiv a te d e la y
T A R E a u to tim e a rriv e d

TARE

S u p p le m e n ta r S ta rt over
y lo a d in g g a te
B a tc h s ta rt o p e n tim e
s ig n a l d e la y s ta r t( S Q 8 )
tim e ( S Q 2 )

S P 3 si g n a l
o u tp u t O N
N N
B a tc h s ta r t d e la y
tim e a rriv e d
S u p p le m e n ta ry N
lo a d in g g a te o p e n N ET < U N D ER
Y tim e a r riv e d
SP2 , SP3
o u tp u t O N Y Y
S P 3 si g n a l
o u tp u t O F F

-N E T ≧
F in a l- S P 2
S u p p le m e n ta r
y g a te c lo s e d
Y tim e s ta rt
( SQ9 )
S P 2 o u tp u t
O FF
N
S u p p le m e n ta ry
l o a d in g g a te c lo s e d
tim e a r riv e d
A
Y

N T im e s o f Y
s u p p le m e n ta ry B
lo a d in g a rriv e d

38
APPENDIX I DESCRIPTION OF 7 SEGMENT CHARACTERS (Attachment 一)
number Display Alphabet Display Alphabet Display

0 A N

1 B O

2 C P

3 D Q

4 E R

5 F S

6 G T

7 H U

8 I V

9 J W

K X

L Y

M Z

39
MODBUS Data Registers
Location Function Status Location Function Status
40001~ 2 As display value R 40003 ~ 4 Gross weight R
40005 ~ 6 Net weight R 40007 ~ 8 Tare value R
40019 ~ 20 Totalised value R 40021 ~ 22 Totalised times R
40023 ~ 24 Totalised times of HI value R 40025 ~ 26 Totalised times of LO value R
40027 ~ 28 Totalised times of OK value
41003 ~ 4 Zero band value R/W 41005 ~ 6 Target value R/W
41007 ~ 8 SP1 value R/W 41009 ~ 10 SP2 value R/W
41011 ~12 SP3 value R/W 41013 ~ 14 LO_LO value R/W
41015 ~16 LO value R/W 41017 ~ 18 HI_HI value R/W
41019 ~20 HI value R/W 41021 ~ 22 Under value R/W
41023 ~24 Over value R/W 41101~ 2 SPAN value R/W
Bit I/O
Location Function Status Location Function Status
00001 Stable status R 00002 Zero status R
00003 Gross R 00004 Net R
00051 Zero Band R 00052 Sp1 R
00053 Sp2 R 00054 Sp3 R
00055 Batch Finish R 00056 Under R
00057 Over R 00058 Discharging R
00059 Hi-Hi R 00060 Hi R
00061 Ok R 00062 Lo R
00063 Lo-Lo R 00064 Peak ready R
00065 Running R 00066 ZERO calibration R
00067 SPAN calibration R 00068 Calibrate ERR0 R
00069 Calibrate ERR2 R 00070 Calibrate ERR6 R
01001 Zero R/W 01002 Clear zero compensation R/W
01003 Tare R/W 01004 Clear tare R/W
01005 Clear pre-tare R/W 01006 Display the gross weight R/W
Totalised the current net weight
01007 Display the net weight R/W 01051 and add 1 to the totalised times R/W

Deduct the last totalised value and Clear the totalised value and
01052 deduct 1 to the totalised times R/W 01053 times R/W
01054 Running R/W 01055 Stop R/W
01056 Discharge starts R/W 01057 Hold mode ON/OFF R/W
01058 Release "Hold value" R/W 01059 Output judgement R/W
01060 ZERO calibration R/W 01061 SPAN calibration R/W
01062 Save to EEP R/W
40