USER MANUAL
CONTENTS
Safety Notification ……...……..……..………….……….…….……………………………..………..…...2
Feature Introduction …...……..……..………….……….…….……………………………..………..…...3
Chapter 1 Specification …....………...……………………….………………………………………....…4
Chapter 2 Front Panel Specification ……,………………….………………………………………….5~6
Chapter 3 Display size .…..……....……..………………….……………………………………………...7
Chapter 4 Function parameter setting description ….....……………………………….…………..8~13
4-1 GEF Function Parameter Description …..……….…………………………….……………8~9
4-2 RSF Function Parameter Description .....………………...................................……….10~11
4-3 SQ RSF Function Parameter Description ………………………………….…………….12~13
Chapter 5 Calibration parameter setting and process ....……………………………….…………14~23
5-1 Calibration.……………………………………………………..………….................................14
5-1.1 01 CSP Specification setting description .....…………......................................15~17
5-1.2 02 CAL Normal calibration description ………………….………………………….....18
5-1.3 Calibration error message ...….…..……………………….……………………………18
5-1.4 03 CLN Linear Calibration Description ….….…………….………...…………………19
5-1.5 04 CV Digital Calibration Description …………………….……………………………20
5-2 Self-test mode …………………….….…………….………………………………….…........21
5-3 INIT Resume factory setting ...…….……. ……….…………….…………………………….22
5-4 MOD Use monitor as the remote display …..…….………………………………………….23
RS-232 & RS-485 serial output / input interface (build-in) ….…………………………………….24~27
Analog current output interface (OP-02) ………………………………………………………………..28
External signal output / input interface (OP-03) ……………………………………………………29~30
Check Weighing Configuration …..………………... ……………………………………………………31
Chapter 6 Maintenance ……………………….………... ………..………….………………...………...32
Calculation signal output condition …..…………. …………………………………………………..….33
Normal load calculation ..….…………..…………. …………………………………………………..….34
Normal unload calculation ……... .…..…………………………………………………………………...35
Normal compare mode ....………..…..…………………………………………………………………...36
Normal Batching (Built-in Program) ..………………………………...…….……………………………37
Loss-in Weight(Built-in Program) …...……………………………………………………………………38
Attachment 一 APPENDIX I DESCRIPTION OF 7 SEGMENT CHARACTERS .............................39
Attachment 二 MODBUS Data Registers ….……………………..….…………………………………40
1
Safety Notification
Do not use directly under sun ray. The ideal operation temperature is -10℃
℃ ~ +40℃
℃
When using high resolution scales to weight, the brass net and sensor should be
grounded at assembling the sensor
2
Feature Introduction
JIF-15A Weight
GW-2000 WeightDisplay
DisplayController
Controller
is is
measurement
measurementtool
tool
with
with
high
high
precision
precision and
and
r resolution.
It can display up to six digits and provide multiple control interfaces. It is a robust, powerful
and delicately designed controller for measuring weight. The features include:
Compact Design
Standardized dimension of 96×48 mm makes it easy to be embedded on a distribution
power panel or mechanical facilities.
High performance CPU and A/D Interface
Apply 32Bits CPU
0.12µVD high sensitivity and resolution
Sampling speed: 120 times/second
Measurement range -0.1 ~ 39 mV
Intellectual Calibration
Normal 2 points calibration
5 points of linear calibration
Optional adaptor
♦ OP-01 RS232 / RS485 /BT
♦ OP-02 16 Bits Analog Electric current output interface (0 ~ 20 mA、0~10V)
♦ OP-03 Control I/O(8I/8O)
Power
♦ Single phase AC voltage 100V ~ 240V or DC voltage 12~24V
♦ Power consumption 5 VA
Others
♦ Operation temperature: -10℃ ~ 40℃ , < 85% RH
♦ Dimension:(mm) 96(W) × 48(H) × 43.5(D)
♦ Weight about 0.2 kg
4
Chapter 2 Front Panel Specification
5
F1 key ◆ “Increase” at functional and parameter setting
◆ Hold and to enter build-in function parameter setting (to set 01-GEF, 02-RSF,03-SQ)
◆ Hold and to enter calibration, self-test mode, and resume factory setting
(01-CSP,02-CAL,03-CLN,04-CV,05-TES,06-INI,07-MOD)
6
Chapter 3 Display size
7
Chapter 4 Function parameter setting description
4-1 GEF Function Parameter Description
0﹕120 times/Sec
1﹕100 times/Sec
2﹕ 80 times/Sec
3﹕ 65 times/Sec
A/D Sampling 4﹕ 25 times/Sec
GEF-01 4
Frequency 5﹕ 12 times/Sec
6﹕ 6 times/Sec
7﹕ 3 times/Sec
8﹕ 2 times/Sec
9﹕ 1 times/Sec
0 NA
1 Weak
2
Digital Filter I
GEF-02 2
I 3
4
Strong
5
Parameter ⇒ Description
0 ⇒ Switch Net Weight/ Gross Weight
1 ⇒ Weight comparison parameter
GEF-04 Set “FUNC” key function 1
setting
2 ⇒ Clear tare value
3 ⇒ Manual communication
4 ⇒ Start calculate
5 ⇒ Stop calculate
6 ⇒ Start weight comparison
7 ⇒ Evacuate material
GEF-05 Set “F1” key function 8 ⇒ Accumulate weight and times 0
9 ⇒ Clear accumulated weight and times
12 ⇒ Gross / Net / Accu V/ Accu C
8
Setting
Item Function Default
Parameter Description
Front panel “ZERO” Parameter ⇒ Description
light 0 ⇒ Zero
GEF-06 0
Display status setting 1 ⇒ MD
(First) 2 ⇒ Gross
3 ⇒ Net
Front panel “MD” light
4 ⇒ Accu. V
GEF-07 Display status setting 1
5 ⇒ Accu. C
(Second)
6 ⇒ SP1
Front panel “GROSS” 7 ⇒ SP2
light 8 ⇒ SP3
GEF-08 2
Display status setting 9 ⇒ Hi
(Third) 10 ⇒ OK
11 ⇒ Lo
12 ⇒ Under
Front panel “NET” light 13 ⇒ Over
3
GEF-09 Display status setting 14 ⇒ Unloading
(Four) 15 ⇒ Running
16 ⇒ Hold
0
Normal hold
Hold
GEF-11 0
Keep the function 1 Peak hold
0 No limit
1 20 times/sec
Rate for display rewrite
GEF-12 2 10 times/sec 0
3 5 times/sec
4 1 times/sec
Normal Correspo
000000 0 (lock disable) nding to
Key – Locked
GEF-13 ↓ keys in 000000
111111 Close front
1 (lock enable)
panel
9
4-2 RSF Function Parameter Description
RSF- 01 2 Net
Transmission 0
format 3 As displayed (simple)
4 Gross(simple)
5 Net(simple)
6 Comparison status + As displayed (simple)
0 Continuous transmitting + command mode
10
0 No limit
1 1 times/sec
RSF- 05
Transmission 2 2 times/sec
0
times 3 5 times/sec
4 10 times/sec
0 ⇒ Continue
000000
RSF- 06 transmission
Transmission
000000
1 ⇒ Stop transmission Weight unstable
conditions Overload(OL)
11
4-3 SQ RSF Function Parameter Description
Setting
Item Function Default
Parameter Description
1 Normal input calculation
2 Normal evacuate calculation
3 Normal compare mode
Compare Mode
SQ- 01 4 build-in programmed input calculation 1
build-in programmed evacuate
5
calculation
12
Setting
Item Function Default
Parameter Description
Start Automatic
0.0 ~ 25.5 Discharge signal is ON when reaching
SQ- 10 discharge 0.0
(sec) delay time.
Delay time
Turn of discharge 0.0 ~ 25.5 Discharge signal is OFF when reaching
SQ- 11 0.0
signal Delay time (sec) delay time.
0 Compare anytime
1 Compare after completing calculation
Hi、OK、Lo Compare when there is external input
2
SQ- 16 Action judgment signal 0
Compare when calculation is completed
3
and there is external input judgment signal
4 Automatic compare
Automatic 0 Turn off
SQ- 17 accumulate 0
1 Turn off
weight/time
Source of weight 0 Input from front panel
SQ- 18 0
compare parameter 1 Input from rear panel
weight comparison
0.0 ~ 25.5
SQ- 19 (Judgment) Hi、OK、Lo weight comparison delay time 0.5
(sec)
delay time
0 press Tare key to tare weight
SQ- 20 Automatic tare 0
1 Automatic tare weight
0 Trigger from external or key
SQ- 21 Automatic discharge 0
1 automatic discharge + manual
13
Chapter 5 Calibration parameter setting and process
0 DSP INT-FN
CSP- 01 1P NO ZERO
1 KEY INTALL
CSP- 02 ZERO 2P NO 0.00000
2 ADC INT-ZO
CSP- 03 3P NO SPAN
3 UAR1
CSP- 04 SPAN 4P NO 2.00000
4 UAR2
CSP- 05 5P NO CAP
5 DA
CSP- 06 020000
6 PNT
CSP- 07
7 EEP
CSP- 08
8 I-O
CSP- 09
Use up, down, left
and right keys to
CSP- 10
choose desired
function
CSP- 11
ESC is to exit
ENTER is to confirm
14
5-1.1 Specification setting description
01 - CSP
* Calibration Parameter Description
Press key
CSP - 01 【Unit】
CSP - 01
15
Setting
Item Function Default
Parameter Description
0 NA
1 g
CSP-01 Unit 2 kg 2
3 t
4 lb
0 NA
1 decimal point one
CSP-02 Decimal 0
2 decimal point two
3 decimal point three
1
2
5
CSP-03 Minimum scale Minimum scare to display weight 1
10
20
50
999999
Maximum Maximum weight to be displayed
CSP-04 ↓ 999999
weight
000000
0 ⇒ full range
Valid set zero 1 ~ 30 ⇒ ±1% ~ ±30%
CSP-05 0 ~ 30 0
range Valid set zero range=calibration zero
point±(Maximum weight × setting%)
Zero point track time needs to be applied
zero point 0.0 ~ 5.0
CSP-06 with zero point track range,Setting to 0.0 will 1.0
track time (sec)
turn off the zero point track time
Zero point track range=(Setting×½)D,
D=minimum scale,
zero point
CSP-07 0~9 Zero point track time needs to be applied 2
track range
with zero point track range, Setting to 0 will
turn off the zero point track function
Stable detection time needs to be applied
Stable 0.0 ~ 5.0
CSP-08 with stable detection range, 1.0
detection time (sec)
Setting to 0.0 will turn off the stable detection
Stable detection time needs to be applied
Stable detection with stable detection range,
CSP-09 0~9 2
range Setting to 0 will turn off the stable detection
16
set zero and 0 Active
tare when
CSP-10 0
weight is not 1 Not Active
stable
Tare when 0 Active
CSP-11 gross weight is 0
1 Not Active
negative
17
5-1.2 Normal calibration description
Choose
ZERO
SPAN
Press key
030000
Weight calibration
Put a sample that is known by its weight on the weight platform or barrel, and key in the weight
by the front panel. After system is stabilized
. ⇒ Setting is 0
18
5-1.4 Linear Calibration Description
1P NO
Press key
001566
Press key
001600
2P NO
5P NO
Follow this procedure to implement calibration. After completion, press key to exit.
19
5-1.5 Digital Calibration Description
04 CV
Method 一 key in zero point
press keys voltage mV/V press key
Method 二
20
5-2 Self-test mode
Hold and keys to enter self-test mode and resume factory setting
1 Keyboard test
6 Under construction
21
5-3 INIT Resume factory setting
Description: Choose the desired option, and then hold the key until PASS is displayed.
This indicates the successful restoration. If you want to cancel this action,
just release the key.
22
5-4 MOD Use monitor as the remote display
**1
Receive ASCΙΙ
Net S T , G S , + 0 1 2 3 4 5 6 k g
Gross S T , N T , + 1 2 3 4 . 5 6 g
Tare S T , T R , + 0 1 2 3 4 5 6 t
Positive
O L , G S , + SP SP SP SP SP SP SP SP SP CR LF
overload
Negative
O L , G S , - SP SP SP SP SP SP SP SP SP
overload
Unstable U S , G S , + 1 2 3 4 . 5 6 k g
Transmit ASCΙΙ
23
RS-232 & RS-485 serial output/input
interface(build-in)
PIN Function
4 TXD / DA +
5 RXD / DA -
6 SG
1. Normal format
Net S T , G S , + 0 1 2 3 4 5 6 k g
Gross S T , N T , + 1 2 3 4 . 5 6 g
Tare S T , T R , + 0 1 2 3 4 5 6 t
Positive
O L , G S , + SP SP SP SP SP SP SP SP SP CR LF
overload
Negative
O L , G S , - SP SP SP SP SP SP SP SP SP
overload
Unstable U S , G S , + 1 2 3 4 . 5 6 k g
2. Simple format
GW/NW or both + 1 2 3 4 5 6 7
Positive overload + SP SP SP SP SP SP SP CR LF
Negative overload - SP SP SP SP SP SP SP
24
RS-485 / 232 command format table
1. Command format A
Host Command
Slave Command
2. Command format B
Host Command
Slave Data
25
3. Command format C
Error message
E1:command format error
E2:set parameter is out of range
E3:condition mismatch
Addressing mode
When RSF-07 address is set as 0, local machine will execute the command after receiving
command.
When RSF-07 address is set as 1~99, local machine will compare the address in front of the
command, and execute command after confirming correctness,
For example: If the host would like to read the current weight of address #2 GW-2000, it can
send the command @02RW<CR><LF>
Final Wt
26
RS-485 Connection figure
Transmission Line:
Twisted pair with outer mask covered is necessary, The quality of transmission line impacts the
signal a lot. Twisted pair with poor quality will cause great lose of signals transmitted at high speed.
The transmission distance will also be greatly decreased, and the ability of anti-noise is lower. So,
please apply high quality twisted pair when it comes to the high transmission speed, long distance,
or heavy noise.
Terminal impedance:
Each signal transmission circuit has it ‘s own characterized impedance. When the signal is
transmitted to the terminal through transmission line, if the terminal impedance is different from the
characterized impedance, reflection will be made and thus result in distortion of the signal wave.
The distortion is not obvious at a short distance, however, with the increasing length of transmission
line, distortion will get more obvious. Under this circumstance, the intermediate impedance is
needed. (Terminal impedance is about 120Ω)
27
Analog current output interface (OP-02)
PIN Function
C1 Common point
X0 IN PUT (set zero)
V+ Voltage output
A+ Current output
02- 03 low weight 000000 ~ 999999 When the weight reaches the set 0
value of AnL-03, current/voltage
02- 04 low current 0.0 mA ~ 20.0 mA output will be the set value of AnL-04 4.0
02- 05 high weigh 000000 ~ 999999 When the weight reaches the set 30000
value of AnL-05, current/voltage
02- 06 high current 0.0 Ma ~ 20.0 Ma output will be the set value of AnL-06 20.0
28
External signal output/input interface (OP-03)
IN - 01 Input 1(X0) 0 ⇒ NA 1
1 ⇒ Zero
IN - 02 Input 2(X1) 2 ⇒ Tare 2
3 ⇒ Tare reset
IN - 03 Input 3(X2) 4 ⇒ Start (L 3
5 ⇒ Stop (L)
IN - 04 Input 4(X3) 6 ⇒ Unload Command 4
7 ⇒ Hold
IN - 05 Input 5(X4) 8 ⇒ Hold display & I/O reset 5
9 ⇒ Accu. Command
IN - 06 Input 6(X5) 10 ⇒ Accu. Clear 6
11 ⇒ Clear previous accumulated value
IN - 07 Input 7(X6) 12 ⇒ Judgment start weight compare 7
13 ⇒ Print manual output streaming and serial data
IN - 08 Input 8(X7) 14 ⇒ Net/Gross 8
29
Hold and keys to enter optional parameter setting OP3-OU
Setting
Item Function Default
Parameter ⇒ Description
OUT- 01 Output 1 1
0 ⇒ NA
OUT- 02 Output 2 1 ⇒ Zero band 2
2 ⇒ SP1
3 ⇒ SP2
OUT- 03 Output 3 4 ⇒ SP3 3
5 ⇒ Batch finish
6 ⇒ Unloading
OUT- 04 Output 4 7 ⇒ Peak ready 4
8 ⇒ Stable
9 ⇒ Internal batching process running
OUT- 05 Output 5 10 ⇒ Under 5
11 ⇒ Over
12 ⇒ Hi
OUT- 06 Output 6 13 ⇒ OK 6
14 ⇒ Lo
15 ⇒ Hi Hi
OUT- 07 Output 7 16 ⇒ Lo Lo 7
17 ⇒ Final
OUT- 08 Output 8 8
30
Check Weighing Configuration
Press key
Display previous set SP1 value, Display previous set Zero Band,
Key in data as requested,, Key in data as requested,Press
SP2 key
press key Final
,
Display previous set SP3 value,
Key in data as requested,
Over
press key
31
Chapter 6 Maintenance
setting screen.
Select 05.TEST to enter detection mode.
◆ DSPDetection
7 level display and LEDs will all light up for 1 second, and all off for 1 second.
Then, 7 level display will display 0~9 and . separately with interval of 1 second. Led will light up
from left hand side to right hand side.
◆ KEY Detection
Turn calibration switch and press keys at front panel. The relative bits should display from i -> I.
◆ ADC Detection
Display range: n0~524287(-1mV ~ 39mV)
◆ UART1 Detection
System send out ASCII 0~9
◆ UART2 Detection
ASCII 0~9。 System send out ASCII 0~9
◆ DA Detection
Press Up or Down to switch between DA output value, 0:LO (zero point value) and 1:HI (full load
value)
◆ PNT Detection (under construction)
◆ EEP Detection
PASS means normal, and FAIL means malfunctioning.
◆ INPUT/OUTPUT Detection
Input port signal ON/OFF corresponds the display digits as i -> I
32
Calculation signal output condition
★ Load calculation signal output condition
Signal Output condition
SP1 Net ≥ Final - SP1
SP2 Net ≥ Final - SP2
SP3 Net ≥ Final - F.Fall
Under Net < Final - Under
Over Net > Final + Over
Zero Band Gross ≤ Zero Band
33
Normal load calculation
Start
tare weight
SP1 output
Stability judgment
<SQ05>
Reaching calculation
completion maintaining
time
34
Normal unload calculation
Start
Batch start
Tare
NET ≥ Finall-SP2
≤ NET<HI
LO≤ weight reaching delay calculation calculation
OK output stabilized time compare compare
signal output signal output
delay time delay time
≤ NET<HI
LO≤ ≤ NET<HI
LO≤ NET < LO NET < LO
OK output OK output LO output LO output
NET ≥ HI NET ≥ HI
HI output HI output
36
Normal Batching (Built-in Program)
Start B C
A
Y SQ5 = 0
SQ14 = 0 Y
Y stabilized
Unloading SQ14 = 1
Unloading unloading
SQ20 = 0 N N continuously
continuously
TARE auto Tare manual Waiting control once
open Comparison delay W eight stabilized control
(SQ20) ( SQ14 )
time arrived SQ14 = 2~255
Unloading
SQ20 = 1 continuously
TARE auto Y
control
SQ21 = 0
N Discharge
Doscharge
Start batch delay Batch finish setting auto manual C
time arrived output signal ( SQ21 ) Unloading control -
delay time to activate delay
start(SQ4) SQ21 = 1 Discharge time arrived
auto
Y
To activate
SP1 , SP2 , discharge on
N delay time
SP3 output ON Reach batch finish ( SQ10 ) start over
output signal delay time
N Y N
NET ≧ SQ7 = 0 not
Discharge delay
To activate supplementar
Final-SP1 supplementar time arrived.
y loading
y loading B
( SQ7 )
Y SQ7 = 1 ~ 255 Y
supplementary
open
SP1 output Discharge signal
OFF output ON
NET < UNDER
Y
A Supplementar Y
y loading gate
closed time Discharge signal
start( SQ9 ) output OFF
N
Time of C
supplementary
loading gate arrived
N To reach times of Y
supplementary B
loading
37
Loss-in Weight(Built-in Program)
S ta r t A B
SQ 15 = 0
Z e ro B a n d n o t s e tt in g W a itin g B a tc h fin is h SQ 5 = 1
< = F in a l W t. c o m p a r is o n n o t s ta b iliz e d
(S Q 1 5 設 定 ) o u tp u t i s
d e a l y tim e s ta b iliz e d o r
s ta rt( S Q 3 ) n ot (S Q 5)
S Q 1 5 = 1 s e ttin g
Y SQ 5 = 0
S ta b iliz e d
N S u p p ly in g b i n w e ig h t C h e c k s u p p ly in g b in is
N
is r e a c h in g z e r o r a n g e e n o u g h f o r n e x t b a tc h W a it in g
or not o f u n lo a d in g W e ig h t s ta b iliz e d
c o m p a ris o n d e la y or not
tim e a r riv e d
Y
Y
Y
S u p p ly in g b in N
g a te o p e n N B a tc h fin i s h
-N E T ≧ s ig n a l o u tp u t
F in a l-F .F a ll
N
B a tc h fin is h
G R O SS≧ SP1 Y o u tp u t s ig n a l
tim e s ta rt
S P 3 o u tp u t ( SQ6 )
Y O FF
SQ 14 = 0
U n l o a d in g S Q 14 = 1
c o n tin u o u s ly U n lo a d in g U n lo a d in g
S P 1 o u tp u t B a tc h f in is h , c o n tr o l c o n tin u o u sl y s in g le
s ig n a l o u tp u t c o n tro l
d e la y tim e ( SQ 14 )
sta r t(S Q 4 ) S Q 14 = 2~255
U n lo a d in g
S u p p ly in g b in c o n tin u o u s ly
c o n tro l
g a te c lo s e d
N T o re a c h u n lo a d in g
B a tc h fin is h , s ig n a l
o u tp u t d e la y tim e
tim e s
N a r riv e d
B a tc h s ta r t s ig n a l Y
in p u t Y
SQ 7 = 0 not U n lo a d in g
T o a c tiv a te s u p p le m e n ta r c o n tr o l - to
s u p p le m e n t a r a c tiv e d e a ly
y lo a d in g
y lo a d in g B tim e s ta rt
Y ( SQ7 ) ( SQ 13 )
SQ 20 = 0 SQ 7 = 1 ~ 255
T o a c tiv a te TARE T o a c tiv a te
TAR E m anual s u p p le m e n ta ry
f u n c tio n lo a d in g
(S Q 2 0 ) U n lo a d in g c o n tro l -
SQ 20 = 1 N ET < UNDER to a c tiv a te d e la y
T A R E a u to tim e a rriv e d
TARE
S u p p le m e n ta r S ta rt over
y lo a d in g g a te
B a tc h s ta rt o p e n tim e
s ig n a l d e la y s ta r t( S Q 8 )
tim e ( S Q 2 )
S P 3 si g n a l
o u tp u t O N
N N
B a tc h s ta r t d e la y
tim e a rriv e d
S u p p le m e n ta ry N
lo a d in g g a te o p e n N ET < U N D ER
Y tim e a r riv e d
SP2 , SP3
o u tp u t O N Y Y
S P 3 si g n a l
o u tp u t O F F
-N E T ≧
F in a l- S P 2
S u p p le m e n ta r
y g a te c lo s e d
Y tim e s ta rt
( SQ9 )
S P 2 o u tp u t
O FF
N
S u p p le m e n ta ry
l o a d in g g a te c lo s e d
tim e a r riv e d
A
Y
N T im e s o f Y
s u p p le m e n ta ry B
lo a d in g a rriv e d
38
APPENDIX I DESCRIPTION OF 7 SEGMENT CHARACTERS (Attachment 一)
number Display Alphabet Display Alphabet Display
0 A N
1 B O
2 C P
3 D Q
4 E R
5 F S
6 G T
7 H U
8 I V
9 J W
K X
L Y
M Z
39
MODBUS Data Registers
Location Function Status Location Function Status
40001~ 2 As display value R 40003 ~ 4 Gross weight R
40005 ~ 6 Net weight R 40007 ~ 8 Tare value R
40019 ~ 20 Totalised value R 40021 ~ 22 Totalised times R
40023 ~ 24 Totalised times of HI value R 40025 ~ 26 Totalised times of LO value R
40027 ~ 28 Totalised times of OK value
41003 ~ 4 Zero band value R/W 41005 ~ 6 Target value R/W
41007 ~ 8 SP1 value R/W 41009 ~ 10 SP2 value R/W
41011 ~12 SP3 value R/W 41013 ~ 14 LO_LO value R/W
41015 ~16 LO value R/W 41017 ~ 18 HI_HI value R/W
41019 ~20 HI value R/W 41021 ~ 22 Under value R/W
41023 ~24 Over value R/W 41101~ 2 SPAN value R/W
Bit I/O
Location Function Status Location Function Status
00001 Stable status R 00002 Zero status R
00003 Gross R 00004 Net R
00051 Zero Band R 00052 Sp1 R
00053 Sp2 R 00054 Sp3 R
00055 Batch Finish R 00056 Under R
00057 Over R 00058 Discharging R
00059 Hi-Hi R 00060 Hi R
00061 Ok R 00062 Lo R
00063 Lo-Lo R 00064 Peak ready R
00065 Running R 00066 ZERO calibration R
00067 SPAN calibration R 00068 Calibrate ERR0 R
00069 Calibrate ERR2 R 00070 Calibrate ERR6 R
01001 Zero R/W 01002 Clear zero compensation R/W
01003 Tare R/W 01004 Clear tare R/W
01005 Clear pre-tare R/W 01006 Display the gross weight R/W
Totalised the current net weight
01007 Display the net weight R/W 01051 and add 1 to the totalised times R/W
Deduct the last totalised value and Clear the totalised value and
01052 deduct 1 to the totalised times R/W 01053 times R/W
01054 Running R/W 01055 Stop R/W
01056 Discharge starts R/W 01057 Hold mode ON/OFF R/W
01058 Release "Hold value" R/W 01059 Output judgement R/W
01060 ZERO calibration R/W 01061 SPAN calibration R/W
01062 Save to EEP R/W
40