Академический Документы
Профессиональный Документы
Культура Документы
Eclipse Manual Russian 3.6
Eclipse Manual Russian 3.6
260-668066-022
Eclipse
Eclipse
260-668066-022 018 2006
, Eclipse 3,6.
Copyright 2007 Harris Harris Stratex Networks
. , , ,
, , ,
, , , , ,
, Harris
Stratex Networks. , : techpubs@hstx.com.
, Harris
Stratex Networks, .
.:
:
.:
:
.:
:
.:
:
,
.
.
.
,
.
-
.:
.:
.:
americas_help@hstx.com
emea_help@hstx.com
asia_help@hstx.com
.
Harris Stratex Networks.
. www.harrisstratex.com. ,
.
(WEEE Waste Electrical and Electronic Equipment ( )
RoHS
RoHs ( ) (2002/95/EC) 1 2006 . Eclipse
, .
. R&TTE, 1999/5/EC
0678
Eclipse R&TTE 99/5/EC 2.8.
-, , ,
.
. .
, .
Harris Stratex Networks , (X).
:, ,
R&TTE. .
Eclipse 7/8
Eclipse 11
Eclipse U6
Eclipse L6
X
X
Eclipse 13
Eclipse 15
Eclipse 18
Eclipse 23
Eclipse 26
Eclipse 28
Eclipse 32
Eclipse 38
X
X
X
Eclipse ............................................................................................ xxix
........................................................................................................ xxix
........................................................................ xxix
.................................................................................................. xxx
................................................................................... xxx
...................................................................................iii-xxx
.................................................................... xxxi
1.
.........................................1-2
........................................................1-3
............................................................................................................1-4
- ...........................................................................1-8
II 1
Eclipse
1.
Eclipse.......................................................................................................... 1-1
Eclipse...................................................................................................... 1-2
300........................................................................... 1-3
100........................................................................... 1-6
Eclipse Node.............................................................................................................. 1-7
.................................................................................... 1-9
...................................................................... 1-11
Eclipse ODU............................................................................................................ 1-16
ODU 300 .......................................................................................................... 1-16
ix
2. Eclipse
IDU PDH SDH ......................................................................................................................... 2-1
................................ 2-2
................................................................. 2-5
PDH .................................................................................... 2-5
SDH .................................................................................... 2-5
AIS PRBS ....................... 2-6
............................................................................................. 2-6
/ ................................................................... 2-7
............................................................................................ 2-8
IDU Ethernet .............................................................................................................................. 2-16
Connect ES ..................................................................................... 2-16
Connect ES............................................... 2-17
IDU ES .................................................................................................... 2-20
Ethernet ................................................................................................................ 2-21
Ethernet- .............................................................................. 2-22
...................................................................... 2-23
...................................................................................... 2-24
..................................................................................... 2-24
(Flow Control) ......................................................................... 2-25
(Disable Address Learning) ............................. 2-25
(Maximum Frame Size) ............................................ 2-26
..................................................................................................................... 2-26
Ethernet................................................................................................. 2-27
................................................................................. 2-27
/ ......................... 2-27
IDU ES.......................................................................................................... 2-29
Connect ES.................................................................................. 2-32
..................................................................... 2-32
........................................................ 2-34
Eclipse
............................................................................................. 2-35
IDU................................................................................................................... 2-36
IDU ...................................................................................... 2-36
IDU .................................... 2-38
IDU .......................... 2-43
................................................................. 2-44
300 ........................................................................................... 2-44
100 ........................................................................................... 2-49
..................................................................................... 2-51
Portal................................................................................................ 2-51
DHCP ........................................................... 2-52
....................................................................................................... 2-52
.......................................................................................................... 2-53
................................................................................................. 2-53
............................................................... 2-53
....................................................................... 2-54
............................................................................... 2-55
3. Eclipse
....................................................................................................................3-1
........................................................................................3-2
............................................................................................3-3
- .................................................................................................3-4
: PDH SDH ..........3-6
: Ethernet .................3-7
Fast Ethernet.....................................................................................................3-8
Gigabit Ethernet................................................................................................3-9
...................................................................3-13
RAC/ODU ...........................................................3-13
.........................................................................................................3-16
......................................................................................................3-16
NCC .......................................................................................................................3-19
NCC ...............................................................................................3-19
NCC ..........................................................3-20
FAN .......................................................................................................................3-22
xi
xii
Eclipse
DAC..................................................... 3-127
NCC NPC............................................................................... 3-128
.................................................................................. 3-129
XPIC ................................................................................................................... 3-129
RAC 40 .................................................................. 3-131
..................................... 3-132
, , ATPC........................... 3-133
............................................................................. 3-133
.................................................................................. 3-146
Portal............................................................................................. 3-146
.................................................................................................... 3-147
....................................................................................................... 3-147
4.
ODU .......................................................................................... 4-1
ODU 300ep 5 .............................................................................................. 4-2
ODU ............................................................................................... 4-3
............................................................................... 4-4
5.
Portal ............................................................................................................................... 5-1
Portal................................................................ 5-2
ProVision ........................................................................................................................ 5-5
............................................................................................... 5-5
...................................................................................... 5-6
ProVision ....................................................... 5-6
6. Eclipse
Eclipse.................................................................................................................... 6-1
.............................................................................................................. 6-2
INU........................................................................................................ 6-2
ODU ...................................................................................................... 6-2
....................................................................................... 6-3
................................................................ 6-3
Super PDH ............................................................................................................... 6-3
xiii
-.......................................................................................... 6-3
.................................................................................................................................. 6-4
................................................................................................................... 6-4
Ethernet................................................................................................................................. 6-4
XPIC............................................................................................ 6-6
/ ............................................ 6-6
Eclipse ........................................................................................................................ 6-6
100 ............................................................................................................................. 6-7
300 ............................................................................................................................. 6-7
ODU .......................................................................................................................... 6-8
.................................................................................................................... 6-8
/ ........................ 6-8
.............................................................................................................................. 6-9
ATPC .................................................................................................................................... 6-9
FEC ....................................................................................................................................... 6-9
................................................................................................. 6-9
(Tx) .......................................................................... 6-10
.................................................................................................. 6-10
........................................................................... 6-10
.................................................................................................. 6-11
.............................................................................................................................. 6-12
...................................................................................... 6-12
.......................................................................................... 6-12
.............................................................................................................................. 6-12
.......................................................................................................... 6-13
......................................................................................................... 6-13
/ ......................................................................................... 6-13
Link () ........................................................................................... 6-13
Ring ()................................................................................................... 6-14
Data () .................................................................................................. 6-14
AUX ................................................................................................................. 6-15
.................................................................................................... 6-15
......................................................................................... 6-15
..................................................... 6-16
............................................................. 6-16
xiv
Eclipse
................................................................................................... 6-16
.................................................................................................................. 6-17
........................................................ 6-17
...................................................................................................................... 6-17
: (NBI) 6-18
NBI .................................................................................................. 6-18
NBI ................................................................................. 6-19
NBI .......................................................................................... 6-19
NBI ................................................................................... 6-19
............................................................................................... 6-20
III 1
Eclipse
1.
.................................................................................................................... 1-1
.................................................................. 1-1
................................................................................................................ 1-2
................................................................................................................ 1-3
............................................................................................ 1-3
........................................................................................................ 1-4
2.
........................................................................................................................... 2-1
ODU ................................................................................................................................ 2-2
ODU, ................................................................. 2-3
.................................................................................................................... 2-3
..................................................................................................... 2-5
ODU ............................................ 2-8
ODU, ............................................................................. 2-9
................................................................................ 2-9
........................................................................... 2-11
..................................................................................... 2-12
ODU .....................................................................................................................2-13
xv
.................................................................................................... 2-14
........................................................................................... 2-15
......................................................................... 2-15
.................................... 2-18
ODU ........................................................................... 2-20
........................................................................................... 2-20
.................................................. 2-21
.................................................................................................. 2-22
-.............................................................................................. 2-24
N - ................................................................................. 2-25
................................................................................................ 2-25
......................................................................................... 2-26
.................................................... 2-27
........................................ 2-27
........................... 2-29
ODU ............................................................. 2-29
................ 2-34
............... 2-39
......................................................................... 2-40
.................................................................................................. 2-40
............................................................................................ 2-41
3. INU INUe
INU/INUe........................................................................................................ 3-1
IDC V1 IDC V2...................................................................................................... 3-2
................................................................................. 3-2
........................................................................................................ 3-3
....................................................................................................... 3-4
INU/INUe................................................................................ 3-4
INU ................................................................................................................. 3-5
............................................................................... 3-9
................................................................................... 3-9
4. IDU
IDU ...................................................................................................................... 4-1
xvi
Eclipse
.....................................................................................................4-3
IDU...............................................................................4-4
IDU ......................................................................................................4-6
5.
............................................................................................................5-1
...............................................................................................5-2
RSL ........................................................................5-2
RSSI ODU.................................................5-3
RSL..................................................................5-3
.............................................................................................5-4
............................................................5-5
..................5-6
XPIC CCDP..5-9
.............................................................................5-13
................................................................5-13
.........................................................5-14
IV 1
Portal
1. Portal
Portal ............................................................................................................1-1
Portal .....................................................................................................1-3
Eclipse....................................................1-7
Portal ..........................................................................1-8
Portal Auto Version................................................................................................1-9
2. Portal
Portal ................................................................................2-1
Portal Eclipse .............................................................2-3
Portal Ethernet TCP/IP .....................................2-5
Ethernet ....................................................2-5
TCP/IP ...........................................2-6
xvii
3.
.............................................................................................................. 3-2
Portal................................................................................................................................ 3-5
.................................................................................. 3-8
.............................................................. 3-12
4.
CompactFlash................................................................................................................... 4-2
..................................................................................................................... 4-3
.................................................................................................................... 4-3
Connect ES ......................................................................................................... 4-4
IDU 300 20xV2 .................................................................................................. 4-6
......................................................................................... 4-7
............................................................................................................... 4-9
xviii
Eclipse
5.
Reports .....................................................................................................................5-2
.............................................................................5-3
...............................................................5-3
6.
7.
Plug-ins ....................................................................................................................7-2
............................................................................................7-4
/ ........................................................................7-4
................................................................7-5
XPIC ........................................................7-6
/ ..............................................7-7
..................................................................................................7-13
..................................................................................................7-19
................................................................7-21
ATPC .............................................................................................7-22
DAC/ .........................................................7-27
.........................................................................................................7-28
........................................................................7-28
DAC 16x, DAC 4x IDU E1/DS1 ..7-31
DAC 3xE3/DS3 ..............................................................................7-36
DAC 3xE3/DS3M...........................................................................7-38
DAC 1x155o, 2x155o 2x155e.....................................................7-42
DAC 155oM ...................................................................................7-47
DAC ES IDU ES .....................................................................7-56
DAC GE .........................................................................................7-67
............................................................................7-89
AUX .......................................................................................................7-93
NMS ....................................................................7-93
Data........................................................................................7-95
NMS.......................................................................................7-97
7-98
xix
AUX.......................................................................................................7-100
/ ................................................7-102
8.
...............................................................................................................................8-1
.............................................................................................8-3
........................................................................................8-4
......................................................8-8
1+1............................................8-9
Protection ...................................................................8-13
Protection .........................................................................8-18
.............................................................................8-19
...................................................................................................................8-23
............................................................................8-23
IDU ....................................................................................8-27
9.
- ......................................................................................9-2
- ......................................................................9-3
- ..............................................................9-5
- ..........................................................................9-6
- DAC ES/GE .......................................................................9-7
- ........................................................................9-9
- - ...................................................9-11
"-"...........................................9-15
DAC ES DAC GE................................................9-17
DAC 3xE3/DS3M...................................................9-18
- ................................................................9-18
- ...............................................9-21
10.
..................................................................10-1
Eclipse............................................................10-2
10-3
Networking......................................................................................................................10-5
xx
Eclipse
11. Eclipse
Alarm Actions........................................................................................................ 11-1
12.
13.
..................................................... 13-1
Software Management ........................................................................................... 13-2
................................................................. 13-3
........................................................................ 13-6
14.
Security .................................................................................................................. 14-1
15.
(System Summary).................................................... 15-2
System Summary................................................................................ 15-4
: ................................................................. 15-6
Event Browser.................................................................................................................. 15-8
Event Browser.............................................................................. 15-10
Event Browser .................................................................................. 15-10
Alarms............................................................................................................................ 15-14
Alarms...................................................................................... 15-15
History ........................................................................................................................... 15-18
History / Graph: RAC .................................................................... 15-18
History / Reports: RAC.................................................................. 15-22
xxi
V1
1.
....................................................................................... 1-1
- ........................................................................................ 1-4
BER............................................................................................................................. 1-4
............................................................................. 1-4
BER ................................................................................... 1-5
xxii
Eclipse
........................................................................................... 1-5
.................................................................................. 1-8
................................................................................... 1-9
....................................................1-11
.................................... 1-13
................................. 1-15
.............................................................................. 1-18
.................................................................................... 1-18
DAC ............................................................................................. 1-20
NCC/NPC .................................................................................................. 1-23
........................................................................ 1-25
2. Eclipse
................................................................................................................... 2-1
ProVision Portal .............................................................................................. 2-1
........................................................................... 2-2
................................................................................ 2-2
Harris Stratex Networks ............................ 2-2
.................................................... 2-3
ProVision ................................... 2-3
........................ 2-4
.............................................. 2-5
.......................................................... 2-8
............ 2-9
............................................... 2-9
............................... 2-10
AIS PRBS.......... 2-13
Eclipse................................................................................................ 2-14
INU/INUe................................................................................... 2-16
IDU............................................................................................. 2-20
Portal .................................................................................... 2-23
Eclipse........................................................... 2-23
NCC ........................................ 2-24
RAC ........................................ 2-25
DAC ........................................ 2-28
xxiii
VI 1
A.
.........................................................................................................................A-2
.................................................................A-2
......................................................................A-4
....................................................................................................A-7
............................................................................A-8
....................................................................................................................A-8
.............................................................................................................A-8
.............................................................................................................................A-9
.................................................A-9
Protection......................................................................................................A-10
....................................................................................A-12
..........................................................................................................................A-14
Eclipse
..................................................................................................................................... A-16
................................................................................................................... A-20
/ ............................................................................................................................. A-21
, A-22
................................................................................................... A-22
........................................................ A-23
........................................................................... A-24
................................................... A-24
.................................................................................................................... A-25
(DAC 155oM) ....................................................................... A-25
.................................................................. A-26
............................................................ A-26
B. Eclipse
NCC/IDU ...................................................................................................... B-2
AUX ............................................................................................................ B-52
NPC ............................................................................................................. B-54
DAC ES....................................................................................................... B-58
.......................................................................................................... B-71
C. Eclipse
......................................................................................................................... C-1
.................................................................................................................................. C-2
RAC/IDU......................................................................................... C-2
RAC............................................................................................................. C-3
RAC 40 .......................................................................... C-3
IDU................................................................................. C-4
RAC/IDU ODU .................................................................................................... C-4
....................................................................................... C-5
ODU ............................................................................................................ C-6
............................................................................................................................. C-6
INU, INUe IDU ........................................................................................ C-9
.......................................................................................................... C-9
IDU............................................................................................................ C-12
DAC, IDU......................................................................................................... C-14
xxv
E1/DS1............................................................................................................................C-14
E3/DS3 (Slim Line BNC) ...............................................................................................C-15
STM1/OC3 (SC, ) .......................................................................................C-16
STM1/OC3 (LC, ) .......................................................................................C-17
STM1/OC3 (BNC)..........................................................................................................C-19
Ethernet RJ45..................................................................................................................C-19
...............................................................................................................C-19
D.
ODU
............................................................................................................D-1
Belden 9913 ......................................................................................................................D-1
Hansen RG-8/U ................................................................................................................D-2
Cinta CNT-400 .................................................................................................................D-2
Cinta CNT-300 .................................................................................................................D-3
Andrew BR-400C .............................................................................................................D-3
: ...............................................D-4
Andrew CNT 300 CNT 400 .......................................................D-4
N- Beldon Kai Jack ................................................................................D-6
: N-........................................................................................D-6
Andrew BR-400 ................................................................................................D-7
Andrew GK-400 .............................................................D-9
E. INU/INUe IDU
DAC IDU ........................................................ E-1
DAC 16x, ........................................................................................... E-2
Mini RJ-21 BNC DAC 16x .............................................. E-2
- Mini RJ-21 RJ-45 DAC 16x ............... E-4
Mini RJ-21 DAC 16x ................. E-8
Mini RJ-21 DAC 16x ...................................................... E-10
DAC 4x IDU................................................................................................................ E-14
RJ-45 BNC DAC 4x IDU............................................ E-15
RJ-45 RJ-45 DAC 4x IDU ............................................... E-16
- RJ-45 RJ-45 DAC 4x IDU.................................................. E-17
RJ-45 DAC 4x IDU............... E-18
xxvi
Eclipse
F. NMS Eclipse
.................................................................................................................... F-1
, ........................................................................................... F-2
....................................................................................... F-7
......................................................................................................................... F-8
.................................................................................................... F-9
.............................................................................. F-10
.............................. F-12
xxvii
................................................................................................................F-17
..............................................................................................................F-23
G.
(1+0) INU/INUe ................................................................. G-1
NCC ................................................................................................................................. G-3
................................................................................................. G-4
TDM- ...................................................................................................................... G-4
RAC 30 ............................................................................................................................ G-4
RAC 10 ............................................................................................................................ G-6
RAC 40 ............................................................................................................................ G-8
, ODU............................................................................. G-9
Rx Tx (Rx/Tx Diversity Bus) ...................................................... G-10
DAC ............................................................................................................................... G-10
ODU 300ep ........................................................................................................................... G-11
.................................. G-13
............................................................................................................. G-15
.................................................................................... G-16
.................................................................................................. G-16
........................................................................................................ G-19
H.
........................................................................... H-1
............................................................................................................ H-2
........................................................................................................... H-5
-........................................................... H-6
-............................................................ H-7
1
i
xxviii
Eclipse
Eclipse Eclipse
Eclipse.
, ,
, .
Eclipse PDH, SDH /
Ethernet
5 38 .
Eclipse
, .
Eclipse.
PDH, SDH Ethernet
5 38 .
,
Eclipse.
.
.
. Harris Stratex
xxix
Networks
Eclipse.
Eclipse
:
.
PDH SDH
.
Ethernet / SDH ,
Eclipse.
Windows.
, ,
,
Eclipse:
xxx
Eclipse
Stratex Networks
(PN 260-668029-001).
.
Stratex Networks
.
:
caution
, .
warning .
note ,
.
xxxi
:
Eclipse,
.
Eclipse
, " IEC
60950".
. I
.
,
.
,
, .
I-1-1
Eclipse.
,
.
Eclipse
" "
(SELV), 48 , 60 .
. .
I-1-2
Eclipse
,
Eclipse.
,
,
.
.
Eclipse I IEC60825-1 /
21CFR1040-1 .
:
.
, , , ,
, .
.
.
/
.
.
.
ODU
. ODU 10 (22 ).
100 (220 ),
.
-: Eclipse
Eclipse , ,
-. ,
-,
.
,
.
I-1-3
,
Eclipse.
Harris Stratex Networks
Harris Stratex Networks.
,
, Eclipse,
. Eclipse,
,
50 (2 )
, .
Eclipse, ,
.
Eclipse
.
,
.
Eclipse
Eclipse
, ,
.
ESD
ESD ( )
.
, ESD ,
.
ESD
,
.
ESD ESD
INU. , ,
.
INU ,
INU, INU
ESD.
I-1-4
Eclipse
,
:
,
- . "
" -.
-
.
" "
-.
,
, .
,
, /
-.
,
-, .
ODU,
.
.
.
.
/
.
Eclipse.
ODU,
ODU, .
ODU Eclipse
().
, , ,
NMS- Eclipse
.
,
.
I-1-5
(Tmra)
Eclipse
+45 C (113 F), +55 C (131 F) ODU.
, ,
. ,
.
, ,
. ,
Eclipse
.
Eclipse
, .
-48 . ;
.
Eclipse.
,
Eclipse.
Eclipse
,
.
(Tmra) +45
Eclipse, ,
,
.
Eclipse
.
, ,
,
. ODU/
I-1-6
Eclipse
: :
Eclipse 110-26 110-27
2002 National Electrical Code ANSI/NFPA 70 (
ANSI/NFPA 70
2002 ).
I-1-7
-
MPE ( )
EN 50383/EN 50385.
.
"" : " ,
, , ,
, ,
".
. 0-1. MPE
()
30.5
30.5
0.5
0.5
()
30.5
30.5
0.5
0.5
()
30.5
I-1-8
5 (4,4 - 5,0 )
()
(,
)
39.3
8.77
32.6
4.06
39.3
0.28
32.6
0.13
L6/U6 (5,25 - 7,11 )
()
(,
)
41.5
11.30
31.2
3.45
41.5
0.36
31.2
0.11
7/8 (7,125 - 8,5 )
()
(,
)
42.9
13.28
()
3.91
1.81
0.12
0.06
()
5.03
1.54
0.16
0.05
()
5.91
Eclipse
30.5
5.0
5.0
()
26.0
26.0
-4.0
-4.0
()
25.0
25.0
2.5
2.5
()
28.0
28.0
0.0
0.00
0.00
30.24
42.9
30.4
3.15
0.71
0.17
10 (10,0 - 10,68 )
()
(,
)
34.3
2.94
33.7
2.74
34.3
0.09
33.7
0.09
11 (10,7 - 11,7 )
()
(,
)
46.2
10.31
27.7
1.23
46.2
0.77
27.7
0.09
13 (12,75 - 13,25 )
()
(,
)
47.3
16.53
29.6
2.15
47.3
0.66
47.3
0.66
29.6
0.09
15 (14,4 - 15,35 )
1.40
0.31
0.07
()
1.31
1.22
0.04
0.04
()
4.59
0.55
0.34
0.04
()
7.36
0.96
0.29
0.29
0.04
I-1-9
()
27.0
27.0
-1.0
-1.0
()
21.5
21.5
-3.0
-3.0
()
21.5
21.5
-3.0
-3.0
()
15.5
15.5
I-1-10
()
(,
)
46.4
13.28
30.8
2.20
46.4
0.53
30.8
0.09
18 (17,7 -19,7 )
()
(,
)
48.0
8.48
32.8
1.47
48.0
0.50
32.8
0.09
23 (21,2 -23,632 )
()
(,
)
49.2
9.73
34.4
1.77
49.2
0.58
34.4
0.11
26 (24,52 - 26,483 )
()
(,
)
46.0
3.37
35.9
1.05
()
5.91
0.98
0.24
0.04
()
3.77
0.66
0.22
0.04
()
4.33
0.79
0.26
0.05
()
1.50
0.47
Eclipse
-4.5
-4.5
()
15.0
15.0
-5.0
-5.0
()
17.5
17.5
-5.0
-5.0
()
17.5
17.5
-5.0
-5.0
46.0
35.9
0.34
0.11
28 (27,5- 29,5 )
()
(,
)
48.1
4.06
36.5
1.07
48.1
0.41
36.5
0.11
32 (31,8 - 33,4 )
()
(,
)
43.5
3.19
37.5
1.60
43.5
0.24
37.5
0.12
38 (37,0 - 39,46 )
()
(,
)
48.1
5.41
39.3
1.96
48.1
0.41
39.3
0.15
0.15
0.05
()
1.81
0.48
0.18
0.05
()
1.42
0.71
0.11
0.05
()
2.41
0.87
0.18
0.07
I-1-11
II
Eclipse
1.
Eclipse.
:
Eclipse . 1-1
. 1-18
. 1-18
. 1-19
. 1-1 .
1-1.
...
...
Eclipse
2.
Eclipse
3.
ODU Eclipse
4.
Eclipse
5.
Eclipse
6.
Eclipse
Eclipse - .
,
. :
Eclipse . 1-2
II-1-1
1.
Eclipse
Eclipse
, IDU
ODU.
IDU: IDU 300 IDU 100.
ODU,
IDU 300 IDU 100.
, IDU
-
.
.
Eclipse, IDU sp,
.
:
300 . 1-3
100 . 1-6
1-1. Eclipse
II-1-2
Eclipse
300
IDU 300 PDH, SDH
Ethernet- ETSI ANSI . . . 1-2.
1-2. IDU 300
E1/DS1
IDU 300 8x
QPSK
16QAM
QPSK
16QAM
QPSK
128QAM
IDUsp 4x
4xE1
QPSK
IDUsp 16x
QPSK
STM1/OC3
IDU 155o
STM1/OC3
16/64/128QAM
Ethernet
IDU ES
10/100Base-T 200 /
8xE1/DS1
QPSK
128QAM
ODU,
5 38 :
5 23 ODU 300ep.
7 38 ODU 300hp ODU
300sp.
IDU 300
IDU 300 20x IDU 300 8x
IDU 300 20x : 4x, 5x, 8x,
10x, 16x, 20xE1/DS1, QPSK 16QAM.
IDU 300 8x :4x, 5x,
8xE1/DS1, QPSK 16QAM.
1-2. IDU 300 20x
RJ-45
E1 DS1.
II-1-3
1.
/
/ .
IDU-
1+1, (Tx)
(Rx) Y-. Tx Rx
.
ODU 300ep, ODU 300hp ODU 300sp.
IDU300 20xV2
IDU 300 20xV2 20
RJ-45 E1 DS1, 128QAM
40xE1 32xDS1.
:
20xE1/DS1
.
40xE1/DS1
.
/ IDU
.
20xE1 / 16xDS1,
IDU, , Y-
.
IDU, IDU,
40xE1 32xDS1 .
(PSU), RAC/ODU
.
(Tx) .
() (Rx) (
).
1-3. IDU 300 20xV2
II-1-4
Eclipse
/
/ .
ODU 300ep, ODU 300hp ODU 300sp.
IDUsp 16x IDUsp 4x
IDU /
E1:
IDUsp 4x: 4xE1 QPSK.
IDUsp 16x: 4x, 8x, 16xE1 QPSK.
1-4. IDUsp 16x
IDU-
. Y-
(Tx) (Rx).
(Tx) .
II-1-5
1.
() (Rx) ( ).
/
/ .
ODU 300ep ODU 300hp.
IDU ES
IDU ES Fast Ethernet 200 /,
. 2-
10/100base-T,
, VLAN QoS.
, 20
200 /, 7 56
16 128 QAM.
Ethernet Ethernet
8 E1/DS1.
.
50 /,
200 /
,
.
1-6. IDU ES
100
IDU 100 . IDU 100
ODU 100 QPSK
II-1-6
Eclipse
ETSI 7 38 .
IDU 8x 4x 8xE1
IDU 16x 4x, 8x 16xE1
IDU 20x 4x, 5x, 8x, 10x, 16x 20xE1 (
ODU 100v2)
RJ-45.
IDU 8x IDU 16 1+0. IDU 20x
1+1,
(Tx) (Rx)
.
/
/ .
1-7. IDU 16x IDU 20x
Eclipse 2.
Eclipse Node
Eclipse
(-)
. Eclipse
5 38 .
,
.
. 1-9 Eclipse, INU (
), ODU.
II-1-7
1.
41
751 4DS1 100xDS1,
SDH-.
II-1-8
Eclipse
:
3 DS3, 8xE3 6xDS3 .
1xSTM1/OC3 2xSTM1/OC3.
Fast Ethernet, TDM-.
Gigabit Ethernet, TDM-.
300 / 600 /
.
:
, ,
.
:
XPIC.
:
. 1-9
. 1-11
INU INUe ( INU).
INU 1U, INUe - 2U.
: NCC ( )
FAN ( ). RAC
( ), DAC ( ), AUX
( ) NPC ( ).
INU
INU NCC FAN,
.
ODU
, /
. ODU
RAC .
II-1-9
1.
1-10. INU
INUe
INUe NCC FAN,
.
ODU
/ .
1-11. INUe
II-1-10
Eclipse
INU/INUe.
3.
NCC
NCC INU/INUe.
, -48
.
-,
.
1-12. NCC
FAN
FAN . FAN
INU, - INUe. FAN
, .
/ 2007 FAN 2U
INUe.
1-13. FAN
RAC 30
RAC 30 ODU 300,
30 :
5x 75xE1
4x 100xDS1
1x 4xE3
1x 3xDS3
1xSTM1/OC3
II-1-11
1.
1-14. RAC 30
RAC 3X
RAC 3X ODU 300,
40 56 :
64/75xE1
32/70/84/100xDS1
5/6/7/8xE3
3/4/5/6xDS3
1/2xSTM1/OC3
1-15. RAC 3X
RAC 40
RAC 40 ODU 300,
XPIC :
64/75xE1
70/84/100xDS1
STM1
1-16. RAC 40
RAC 10
RAC 10 ODU 100,
4x 20xE1.
1-17. RAC 10
DAC 4x
DAC 4X 4xE1 DS1
RJ-45.
II-1-12
Eclipse
1-18. DAC 4x
DAC 16X
DAC 16X 16xE1 DS1
Mini RJ-21.
1-19. DAC 16x
DAC 3xE3/DS3
DAC 3xE3/DS3 BNC
E3 DS3.
1-20. DAC 3xE3/DS3
DAC 3xE3/DS3M
DAC 3xE3/DS3M :
E3/DS3 (
DAC 3xE3/DS3)
E13.
E3 NxE1 .
E3 34 /
(MPEG).
E3 34xE1 .
1-21. DAC 3xE3/DS3M
DAC 2x155e
DAC 2x155e BNC
STM1.
1-22. DAC 2x155e
II-1-13
1.
DAC 1x155o
DAC 1x155o
STM1/OC3 SC-.
1-23. DAC 1x155o
DAC 2x155o
DAC 2x155o
STM1/OC3 SC-.
1-24. DAC 2x155o
DAC 155oM
DAC 155oM
SDH/OC3 NxE1 NxDS1 ..
1-25. DAC 155oM
DAC ES
DAC ES Ethernet- 10/100Base-T
/
. :
QoS.
, VLAN .
100 / .
.
Ethernet
Ethernet E1/DS1
.
DAC GE.
1-26. DAC ES
II-1-14
Eclipse
DAC GE
DAC GE Ethernet- 10/100/
1000Base-T 1000Base-LX
. :
QoS.
, VLAN .
, RSTP
(L1) (L2).
VLAN.
300 / .
.
Ethernet
Ethernet E1/DS1
.
DAC ES.
1-27. DAC GE
AUX
AUX
, NMS,
. 64 /,
19,2 /.
1-28.
NPC
NPC NCC
TDM- .
1-29. NPC
Eclipse 3.
II-1-15
1.
Eclipse ODU
ODU.
() (Tx)
. ODU 300ep,
5 .
(Tx) ,
,
7/16 female DIN .
ODU 6 38
, .
ODU 300ep 5
.
:
ODU 300 . 1-16
ODU 100 . 1-17
ODU 300
ODU 300: ODU 300ep, ODU 300hp, ODU 300sp.
ODU 300 ODU 300ep. .
ODU 23 ,
,
ODU 300ep.
3,5 56
ODU,
/.
ODU 300ep ODU 300hp
. ODU 300sp
ODU 300sp.
ODU 300ep :
5 23
4x 75x E1 4x 100x DS1
1x 8x E3 1x 6x DS3
1/2x STM1/OC3
300 / Ethernet
QPSK 256QAM
RAC 30, RAC 40, RAC 3X, IDU 300 IDUsp
II-1-16
Eclipse
ODU 300hp :
7 38
4x 75x E1 4x 100xDS1
1x 8x E3 1x 6xDS3
1/2x STM1/OC3
300 / Ethernet
QPSK 256QAM
RAC 30, RAC 40, RAC 3X, IDU 300
ODU 300sp :
7 38
4x 40x E1 4x 32xDS1
80 / Ethernet
QPSK 16 QAM
RAC 30, IDU 300 IDU 155o
ODU 100
ODU 100v21 RAC 10 IDU 100
:
4x, 5x, 8x, 10x, 16xE1 20xE1
QPSK
7 28
7 38
ODU Eclipse 4.
II-1-17
Eclipse - ,
.
Portal ProVision.
Portal
Eclipse.
ProVision Harris Stratex
Networks.
Portal Eclipse.
,
, ,
, Portal
.
Portal
Windows,
.
Portal INU/INUe/IDU, Ethernet V.24
.
ProVision Eclipse,
XP4, DXR, ADR, Altium Spectrum.
ProVision Windows, Solaris,
, ,
LAN/WAN IP- .
IP-.
Portal ProVision 5.
Eclipse ODU
0,3 (1 ) 1,8 (6 ),
.
Eclipse
( ODU) .
.
.
115 (4,5 inch).
ODU Eclipse
.
Eclipse -48
( ),
-40,5 60 .
UL IEC -48 (60 ).
II-1-19
1.
II-1-20
2. Eclipse
Eclipse.
:
IDU PDH SDH . 2-1
IDU Ethernet . 2-16
IDU . 2-36
. 2-44
. 2-51
ODU Eclipse 4.
IDU 300 8x
IDUsp 4x
4xE1
IDUsp16x
IDU 155o
STM1/OC3
II-2-1
2. Eclipse
1.
IDU 100
IDU
IDU 8x
4x, 8xE1
IDU 16x
IDU 20x
:
. 2-2
. 2-5
. 2-8
IDUsp IDU 155o
Connect, ,
IDU
ODU 300 .
ODU
-.
IDU/ODU /
, QPSK, 16QAM, 32QAM, 64QAM,
128QAM:
QPSK IDU PDH 100 300.
16QAM IDU 300 8x, IDU 300 20x, IDU 300
20xV2.
QAM ( 128 QAM) IDU 300
20xV2, IDU 155o ( ODU 300ep ODU 300hp).
. 2-1 . 2-3
( ETSI), IDU
PDH ETSI.
II-2-2
Eclipse
. 2-2 . 2-4 ,
IDU PDH
(ANSI) .
. 2-3 . 2-4
ETSI ANSI ,
IDU 155o.
55/56 ETSI, ,
18 .
50 ANSI ,
, 18 .
QPSK
8xE1
13.75 / 14
QPSK
10xE1
13.75 / 14
QPSK
16xE1
27,5 / 28
QPSK
20xE1
27,5 / 28
QPSK
4xE1
3,5
16QAM
5xE1
3,5
16QAM
8xE1
16QAM
10xE1
16QAM
16xE1
13.75 / 14
16 QAM
16xE1
64 QAM
20xE1
13.75 / 14
16 QAM
32xE1
13.75 / 14
64 QAM
40xE1
27,5 / 28
16 QAM
X
X
IDU 20x
5xE1
IDU 16x
QPSK
IDU 8x
IDUsp 16x
4xE1
IDUsp 4x
IDU 300 8x
X
X
X
X
X
X
II-2-3
2. Eclipse
IDU 300 8x
4xDS1
2.5
16 QAM
8xDS1
10
QPSK
8xDS1
16 QAM
8xDS1
3,75
32 QAM
16xDS1
20
QPSK
16xDS1
10
16 QAM
16xDS1
128 QAM
28xDS1
30
QPSK
28xDS1
20
16 QAM
28xDS1
10
64 QAM
32xDS1
20
16 QAM
II-2-4
STM1/OC3
27,5
128 QAM
STM1/OC3
40
64 QAM
STM1
55
16 QAM
Eclipse
:
PDH . 2-5
SDH . 2-5
. 2-6
IDU Ethernet . 2-16
PDH
IDU PDH 100 300
RJ-45.
(75 )
(120 ) E1 .
DS1
AMI, B8ZS. 100 ,
.
:
RJ-45 2xBNC.
RJ-45 RJ-45 -
RJ-45.
- RJ-45 RJ-45 IDU
.
RJ-45 .
Y-c,
" ".
E.
SDH
IDU 155o STM1/OC3
. SC
- SC, FC LC .
-31 ( ) -7
( ). -15
-8 .
Y-, SC SC, FC LC .
II-2-5
2. Eclipse
AIS
PRBS
RAC,
(AIS PRBS15)
. (
).
E1 DS1 AIS.
STM1/OC3 PRBS15
(15- ).
,
.
AIS/PRBS15
, System Control ( ).
IDU IDUsp
. IDUsp
. DB-9
female.
64/
TIA/EIA-422 / V.11 c
.
(
) ( ).
,
(
).
TIA/EIA-562 /
V.24 ( RS-232/V.24).
: 1200, 2400, 4800, 9600, 19200 /,
.
II-2-6
Eclipse
NMS.
:
DB-9 .
DB-9 .
DB-9 DB-9 -.
C DB-9 DB-9 -.
E.
/
IDU, IDUsp,
. (IDUsp
/ ).
/ TTL-
Form C. HD-15
female.
:
AUX
.
.
IP-
, , Eclispse,
IP-
AUX.
/ HD-15
.
E.
TTL- ,
, .
, , ,
. 1 .
.
ID
().
II-2-7
2. Eclipse
.
TTL- : 2 , 0,8 - .
( )
48.
.
(- -)
/ .
:
250
2 ( 30 )
60
: ,
,
.
60 ,
SELV.
IDU 16x, IDUsp, IDU 300 20x IDU 155o.
. 2-1 IDU 16x ( 100).
. 2-2 IDU 16x.
. 2-3 IDU 300 20x,
IDU 300 20xV2.
. 2-4 IDU 155o.
. 2-4.
. 2-1. IDU 16x
II-2-8
10
11
Eclipse
12
17 8
13
5 12
13
12
16
II-2-9
2. Eclipse
. 2-4.
IDU .
IDU. IDU
,
.
-48 .
5 ON/OFF. ON
,
OFF - 0.
To ODU
N- female -
,
.
Maint V.24
RJ-45 Portal
V.24. IP-
, IP- .
Aux Data
HD-15
TTL Form C.
Portal.
ODU
II-2-10
IDU
,
/
,
Tx Mute ( ).
Eclipse
IDU
(
)
IDU
,
/
,
.
(
): LOS ( )
SW/HW (/
)
II-2-11
2. Eclipse
NMS 10/100Base-T
RJ-45
Ethernet:
IDU, V.24
DHCP, Portal
IP- TCP/IP
Portal.
IDU, V.24
DHCP, Portal DHCP
Obtain an IP address automatically ( IP-
) TCP/IP Portal.
IDU, V.24,
DHCP Portal Ethernet.
IDU
RJ-45 NMS -,
Portal.
,
Harris Stratex
.
Ethernet-. IDU,
:
IDU
()
()
IDU 155o
IDUsp
IDU 16x / 8x
, Ethernet
.
.
, Ethernet-.
( ), .
( ,
).
II-2-12
Eclipse
10, 11
RJ-45 ;
RJ-45 E1.
- Portal.
BNC ,
RJ-45 .
(IDU PDH 300 E1 DS1, Portal)
II-2-13
2. Eclipse
12
/
.
:
IDU 20x
IDU300 8x
IDU300 20x
IDU 300 20xV2
IDUsp 16x
IDU 155o
RJ-45.
IDU 20x, IDU300 8x, IDU300 20x IDUsp 16x
, 1+1 " ".
.
IDU 300 20xV2 IDU 155o
IDU
. (Tx)
, () (Rx)
.
IDU 20xV2 (),
20xE1 / 16xDS1. IDU
IDU 40xE1
32xDS1 .
(PSU), RAC/ODU .
IDU, IDUsp 16x, (Tx)/
(Rx) "/"
:
(online LED)
Tx() / Rx(). (
IDU (Tx) (Rx)).
(online LED) ,
IDU (IDU
(Rx)). ( IDU 300 20xV2 IDU 155o ).
(Primary LED) ,
IDU. ( IDU
(Tx) (Rx)).
(Primary LED) ,
IDU.
IDUsp 16x ,
, -
1"/"
II-2-14
Eclipse
13
RJ-45 ;
RJ-45 E1 (IDU 20x) E1/DS1 (IDU300 20x / 20xV2).
E1
Portal. DS1 100
AMI B8ZS .
BNC ,
RJ-45 .
16
Optical 1
SC-
.
-31 ( )
-7 dBm ( ). -15
-8 .
SC, FC LC .
IDU Y-,
(Tx) (Rx).
17
( ) ,
:
Ethernet DHCP. ,
IDU ( IP-).
IDU; IDU
.
. 2-55.
1.
Eclipse,
IDU .
II-2-15
2. Eclipse
IDU Ethernet
IDU ES Eclipse Connect ES .
:
Connect ES . 2-16
Connect ES . 2-17
IDU ES . 2-20
Ethernet . 2-21
. 2-27
/
. 2-27
IDU ES . 2-29
Connect ES . 2-32
. 2-35
Connect ES
, IDU ES ODU 300 -,
Connect ES,
, IDU ES
ODU 300,
.
ODU
-.
Ethernet,
,
(Tx), Connect ES ODU 300ep, hp
sp.
IDU ES 2-
10/100base-T,
, VLAN QoS.
ODU ,
, ,
QPSK 128QAM.
Ethernet- Ethernet-
8xE1 8xDS1 .
, ,
II-2-16
Eclipse
.
Connect ES . 2-17
,
Ethernet
.
Connect ES . 4-3, IV,
.
Connect ES
,
Eclipse, INU RAC 30v3 RAC 3x, ODU 300 DAC
ES. , E1/DS1, INU
DAC4x DAC 16x. ,
AUX,
.
Connect
ES
ESTI . 2-5 . 2-5.
ANSI . 2-6 . 2-6.
's' Connect ES
ODU 300sp. s ODU 300ep ODU
300hp.
Connect ES ODU 300ep ODU 300hp
Connect ES 50 ( 65 /).
Connect ES 100, Connect ES 150 Connect ES 200.
Connect ES ODU 300sp Connect ES 40s
( 41 /). Connect ES
80s.
Connect ES ,
. :
Connect ES 50
ETSI
; 10xE1 20 /
201 40 /.
Connect ES 40s ETSI
10xE1,
20 /.
Connect ES 40s ETSI
40xE1,
82 /.
II-2-17
Connect
ES Ethernet-,
Ethernet E1/DS1-. ,
Ethernet,
Ethernet 2 / (2,048 /)
1, 1,5 / (1,544/)
DS1, 8xE1/DS1
.
Connect 200 Ethernet
96x1
127xDS1 Ethernet, 196,6
/ 196 / . Connect 200
ETSI 217 /
,
Ethernet; Connect 200 ETSI
Ethernet 196,6 /
8xE1 .
. 2-5. Connect ES ETSI c ODU 300ep/hp.
Eclipse
4/8xE1
Ethernet (), /
NxE1
+ 4xE1
+ 8xE1
Connect ES 40s
16 QAM
10
20.5
12.3
4.1
Connect ES 40s
27.5
QPSK
20
41
32.8
24.6
Connect ES 50
16 QAM
10
20.5
12.3
4.1
Connect ES 50
27.5
QPSK
20
41
32.8
24.6
Connect ES 50
27.5
16 QAM
32
65.5
57.3
49.2
Connect ES 80s
27.5
16 QAM
40
82
73.7
65.5
Connect ES 100
27.5
16 QAM
40
82
73.7
65.5
Connect ES 100
27.5
32 QAM
52
106.5
98.3
90.1
Connect ES 150
27.5
128 QAM
75
153.6
145.4
137.2
Connect ES 150
55
16 QAM
75
153.6
145.4
137.2
Connect ES 200
56
64 QAM
106
196.6
196.6
196.6
. 2-6. Connect ES
ANSI
II-2-19
2. Eclipse
4/8xDS1
Ethernet (), /
Connect ES
NxDS1
+ 4xDS1
+ 8xDS1
Connect ES 50
10
64 QAM
28
43.2
37
30.8
Connect ES 501
20
16 QAM
32
49.4
43.2
37
Connect ES 501
40
QPSK
32
49.4
43.2
37
Connect ES 100
20
128 QAM
70
108.1
102
95.7
Connect ES
1001
30
32 QAM
70
108.1
101.9
95.7
Connect ES
1001
40
16 QAM
70
108.1
102
95.7
Connect ES 150
30
128 QAM
100
154.4
148.2
142
Connect ES 150
40
32 QAM
100
154.4
148.2
142
Connect ES 150
50
16 QAM
100
154.4
148.2
142
Connect ES 200
40
128 QAM
127
196.1
189.9
183.7
Connect ES 200
50
64 QAM
127
196.1
189.9
183.7
1.
FCC ,
6 11 .
IDU ES
IDU ES INU/INUe,
RAC 30v3 RAC 3X.
. 2-7
ETSI; . 2-8 ANSI.
, Harris Stratex
Networks .
INU/INUe:
Ethernet- DAC ES DAC GE.
E1/DS1- DAC 16 DAC 4.
/ /
AUX.
II-2-20
Eclipse
Ethernet
(E1)
20 /
10xE1
40 /c
RAC30v3
RAC3X
IDU300ES+8E1
16QAM
20xE1
QPSK
28
80 /
40xE1
16QAM
28
100 /
52xE1
32QAM
28
150 /
75xE1
16QAM
58
150 /
75xE1
128QAM
28
Ethernet
(DS1)
RAC30v3
RAC3X
IDU300ES+8E1
50 /
32xDS1
QPSK
40
50 /
32xDS1
QPSK
20
100 /
70xDS1
16QAM
40
100 /
70xDS1
32QAM
30
150 /
100xDS1
16QAM
50
150 /
100xDS1
32QAM
40
Ethernet
Ethernet 2+,
,
C1 C2.
Ethernet- ,
2 3 .
/ .
- 4096 .
Fast Ethernet 10/100Base-T
, VLAN .
E1 DS1,
, E1
2.048 /, DS1 - 1.544 /.
II-2-21
2. Eclipse
48xE1- 64xDS1-
98 /. , ,
196 /.
:
Ethernet- . 2-22
. 2-23
. 2-24
. 2-24
(Flow Control) . 2-25
(Disable Address Learning) . 2-25
(Maximum Frame Size) . 2-26
. 2-26
Ethernet . 2-27
Ethernet-
Eclipse Connect ES Portal,
Eclipse.
( Ethernet), , QoS
.
,
LAN- . :
"", "VLAN" "":
, ;
.
( 1 4)
(C1, C2).
. 2-7.
VLAN
VLAN
II-2-22
Eclipse
LAN-. 1 1, 2 4
2,
LAN- (VLAN 2, 3 4). VLAN
2.
.
. 2-8. VLAN
LAN .
1 1.
() ,
2, 3 4 2. ,
,
, 1 1.
. 2-9.
:
E1 DS1,
48xE1 64xDS1
Ethernet 98,3 98,8 /.
,
Ethernet 196 /c (98xE1 127xDS1)
Connect 200.
VLAN- fast Ethernet ,
.
II-2-23
2. Eclipse
:
, ,
10 / 100 /.
, IDU ES ,
.
; Mdi MdiX ( -
). ,
,
.
: , , .
,
.
8:4:2:1,
8
.
. .
Port Default ( )
(
- " " ).
VLAN 802.1p
DiffServ IP.
802.1p ,
VLAN 802.1p.
(2- ) .
, Port Default
.
II-2-24
Eclipse
DiffServ ,
Type of Service DiffServ IP.
63 (2- )
. ,
Port Default .
802.1p-then-DiffServ (802.1p--DiffServ)
, VLAN 802.1p,
Type of Service DiffServ. ,
Port Default .
DiffServ-then-802.1p (DiffServ--802.1p)
, Type of Service DiffServ
IP, VLAN 802.1p. ,
Port Default .
(Flow Control)
Flow Control ( )
. PAUSE
IEEE 802.3x,
, ,
.
,
, ,
. ,
, , ,
IDU ES
(flow control).
(Disable Address
Learning)
Address Learning ( )
Ethernet- .
(Address Learning)
,
Ethernet- RSTP-.
,
IDU ES, RSTP-
, IDU ES .
, Ethernet,
Ethernet-
, IDU ES /
,
/ , 5
.
II-2-25
2. Eclipse
, ,
. IP-
(VoIP)
-; , .
200
.
; Intranet 5
, , ,
,
.
, Eclipse,
, , VoIP
, IP-,
. ,
.
. 2-9
Connect ES 100 / ( )
. 2-9.
100 /.
II-2-26
64
240
72 /
128
250
83 /
256
270
88 /
512
300
93 /
1024
390
95 /
1518
460
95,5 /
Eclipse
Ethernet
Portal
Ethernet . IDU ES
:
/.
(Rx)
(Tx) .
(Rx)
(Tx), .
.
RMON .
.
IV, 15:
8xE1 8xDS1
.
RJ-45.
E1: 75
120 .
DS1 AMI B8ZS
. 100 .
AIS, PRBS
BER .
.
/
,
TTL- , :
II-2-27
2. Eclipse
DB-9
,
NMS (
):
64/
TIA/EIA-422 / V.11 c
.
( Connect ES)
( ).
,
(
).
TIA/EIA-562 /
V.24 ( V.24).
: 1200, 2400, 4800, 9600, 19200 /,
.
NMS.
/
/ HD-15
TTL Form C.
Eclipse. ,
.
. IP-
, ,
Eclispse, IP-,
AUX.
TTL- ,
, .
, , ,
. 1 .
.
( ). ,
II-2-28
Eclipse
(- -)
/ .
TTL
,
/ . 2-7.
IDU ES
. 2-10 IDU
ES.
. 2-10. IDU ES.
14
15
IDU .
IDU. IDU
,
.
-48 .
5 ON/OFF. ON
,
OFF - 0.
To ODU
N- female -
,
.
Maint V.24
RJ-45 Portal
V.24. IP-
, IP- .
Aux Data
DB-9
. (64
/c) ( 19,2 /c)
Portal.
II-2-29
2. Eclipse
HD-15
TTL Form C.
Portal.
ODU
IDU
NMS 10/100Base-T
IDU
,
/
,
Tx Mute ( ).
(
)
IDU
,
/
, ,
.
(
)
RJ-45
Ethernet: DHCP , Portal
IP- .
, NMS
Harris Stratex
.
,
Ethernet- .
.
,
Ethernet-. ( ),
. ( ,
).
II-2-30
Eclipse
14
15
RJ-45
; RJ-45 E1/DS1. E1
Portal. DS1 100
AMI B8ZS .
BNC ,
RJ-45, .
II-2-31
2. Eclipse
Connect ES
Connect ES
.
:
. 2-32.
. 2-34
. 2-11 , IDU ES
4 ,
LAN VLAN- VLAN,
C1 2.
. 2-11. Connect ES
E1/DS1
IDU ES
1- 4 10/100Base-T
LAN-
C1/C2
C1/C2
IDU ES
E1/DS1
1- 4 10/100Base-T
LAN-
, Connect ES
Ethernet 98 /. ,
Connect ES LAN-
Ethernet-
196 / ( Connect 200).
Ethernet-
E1 DS1, 8
1xE1/DS1. , ,
106 /
( Connect 100 ETSI),
:
Ethernet- 106 /,
, E1.
(LAN) 53/53 / 98/8
/.
Ethernet- 104 / 1, 90 /
Ethernet- 8xE1.
II-2-32
Eclipse
LAN-, 1 2,
,
IP-.
, IDU ES
,
,
, ,
LAN
( ).
2
, . 2-12.
. 2-12. Connect ES :
E1/DS1
IDU ES
C1
C1
P1
Nx LAN
10/100Base-T
IDU ES
P1
Nx LAN
10/100Base-T
L2
E1/DS1
L2
, LAN QoS
,
IDU ES.
(C1 C2),
Ethernet 98 /.
Connect
100.
Connect ES 150 (~150
/) Connect ES 200 (~200 /),
, IDU ES ,
. 2-13. IDU ES "
" LAN-/VLAN-
1 2, -
.
. 2-13. onnect ES :
E1/DS1
IDU ES
Nx VLAN1
10/100Base-T
C1 & C2
C1 & C2
P2
P1
L2
Nx VLAN2
10/100Base-T
Nx VLAN1
10/100Base-T
E1/DS1
IDU ES
P2
P1
L2
Nx VLAN2
10/100Base-T
II-2-33
2. Eclipse
Connect ES ,
. . 2-14
IDU
ES B.
2 ,
LAN : , .
D . ,
, IDU ES
.
, E1/DS1.
NMS IDU ES
NMS Ethernet . IDU ES
NMS Ethernet, ,
, B,
.
. 2-14. Connect ES,
A
E1/DS1
B
IDU ES
P1
Nx LAN
10/100Base-T
L2
C1
C1
C
IDU ES
IDU ES
L2
C1
P1
P1
C1
P1
P1
IDU ES
IDU ES
L2
C1
C1
IDU ES
P1
P4
Connect ES 1+0;
. Connect ES
,
Ethernet-, RSTP-.
, . 2-15,
98 /.
, 1 2,
, 98 /.
II-2-34
Eclipse
, ,
,
LAN-.
NMS , IDU ES
NMS Ethernet.
E1/DS1
- ( ).
. 2-15. Connect ES
A
RSTP
IDU ES
IDU ES
C1
C1
B
C1
IDU ES
C1
RSTP
IDU ES
IDU ES
C1
RSTP
IDU ES
Ethernet
C1
C
C1
IDU ES
C1
C1
C1
IDU ES
IDU ES
RSTP
IDU ES
RSTP
Connect ES IDU ES:
" " . 4-1, IV.
""
. 7-1, IV.
Harris Stratex Networks Connect ES Product
Description ( Connect ES).
Harris Stratex Networks
.
II-2-35
2. Eclipse
IDU
IDU :
IDU
IDUsp 16x
IDU 300 8x
IDU 155o
(Rx) (Tx)
, IDU 300 20xV2 IDU 155o,
(Rx) ( )
.
:
IDU . 2-36
IDU . 2-38
IDU . 2-43
IDU
IDU 1
ODU, RJ-45 NMS-. Y-
/ .
. 2-16 .
IDU
IDU 300 20xV2 20xE1 / 16xDS1:
IDU / , ,
,
, 8- IDU 300 8x IDU
300 20x.
II-2-36
Eclipse
20xE1 / 16x DS1;
Y-.
IDU, IDU,
40xE1 32xDS1 .
(PSU), RAC/ODU .
. 2-16. IDU
1
3
4
5
Tx Rx
.
IDU INU.
IDU,
.
NMS
Y-
100/120 .
:
- RJ-45 RJ-45
RJ-45 RJ-45
RJ-45
II-2-37
2. Eclipse
:
3,5
IDU.
1,6 6,4
.
.:
IDU
IDU
IDU
(Rx) (Tx) ,
(Tx),
(Rx) (Tx),
(Tx) (Rx)
IDU. ,
(Rx)2.
( IDU
(Tx) (Rx)).
(Tx) , .
(Rx) ,
(Rx)
(Rx) .
IDU .
:
: IDU IDU 300 20xV2
IDU 155o
: IDU 300 20xV2 IDU 155o
(Tx): IDU.
(Rx) ,
(Rx) - IDU, IDU (Rx).
II-2-38
Eclipse
(Rx): IDU
IDU 300 20xV2 IDU 155o
(Rx): IDU 300 20xV2 IDU 155o
,
3. .
,
.
. ,
.
,
:
( )
,
( ).
,
.
,
(Tx), - (Rx).
5
320 (5 26 ).
.
: IDU IDU 300 20xV2
IDU 155o
Tx Rx .
, ,
(Tx) (Rx)
System/Controls (/ ).
( ) (Rx).
II-2-39
2. Eclipse
(Tx),
(Rx),
(Tx),
,
System/Controls.
(Rx), (Tx),
.
(Rx),
(Tx) , , IDU
, - .
(Rx) .
,
(Tx) (Rx),
Portal.
. /
.
.
: IDU 300 20xV2 IDU 155o
.
(Tx) .
(Rx)
( )
(Rx).
IDU, , IDU
(Rx)
. ( ).
IDU (Rx)
(Rx) ( (Rx))
IDU (Tx)
( IDU
(Tx) (Rx)).
(Rx)
(Rx) ( (Rx)
IDU 300 20xV2 IDU
155o).
II-2-40
Eclipse
(Tx),
(Rx),
(Tx),
,
System/Controls.
(Rx), (Tx),
.
(Rx),
(Tx) , , IDU
, - .
(Rx)
(Rx) Systems/Controls.
.
(Tx) (Rx).
(Tx): IDU.
(Tx)
:
(Tx):
(Tx)
(Tx)
(Tx)
ODU ( 100)
(Tx)
( 300)
(Tx) ODU
( 300)
ODU
LIU
LOS n ( LOS
n - IDU). ,
LOS IDU 300 20xV2,
20xE1 / 16xDS1.
. ,
II-2-41
2. Eclipse
IDU (
),
4.
(Rx): IDU
IDU 300 20xV2 IDU 155o
(Rx)
:
(Rx)5:
(Rx)
IDU
ODU
(Rx) ( IDU
300)
ODU
LIU
(Rx): IDU 300 20xV2 IDU 155o
.
(Rx) (Rx)
:
LIU
( IDU 300 20xV2)
- - ,
. "
(Tx)"
, ,
(Tx) () .
5 , - IDU
.
II-2-42
Eclipse
IDU
:
IDU:
200 (Tx)
: IDU 20x.
200 (Tx)
: IDUsp 16x, IDU 300 8x, IDU 300 20x, IDU 300 20xV2
IDU 155o.
20 (Tx).
IDU, IDU 20x:
200 c
(Rx), LIU.
1,2 . IDU
,
, .
, 200 ,
.
IDU, IDUsp 16x, IDU 300 8x IDU 300 20x:
200 c
(Rx), LIU.
1,2 . IDU
,
, .
, 200 ,
.
IDU, IDU 300 20xV2 IDU 155o:
(Rx) ( )
(Rx).
(Rx),
200 . ( (Rx)
- .
IDU
-, ).
II-2-43
2. Eclipse
,
:
300 . 2-44
100 . 2-49
300
. 2-10 300 :
.
ODU.
.
. 2-11 . 2-47 IDU/ODU
.
. 2-10. 300
IDU
IDU 300sp 4x
ODU 300sp/hp
QPSK
Eclipse
(
)
ODU 300sp/hp
QPSK
Eclipse
(
)
II-2-44
Eclipse
IDU
ODU 300ep/hp/sp
QPSK 16QAM 4 20x E1/DS1
Eclipse (ODU 300,
RAC 30v1/v2,
DAC 4/16x, AUX)
/
ODU 300ep/hp/sp
QPSK 128QAM 5 40xE1,
4x 32xDS1
, ,
,
Eclipse (ODU 300,
RAC 30v3, DAC 4/16x, AUX)
/
IDU 155o
ODU 300ep/hp
16/64/128/QAM 1xSTM1/OC3
, ,
Eclipse (ODU 300,
RAC 30v3,
RAC 3X,
DAC 155o, AUX)
/
II-2-45
2. Eclipse
IDU
IDU ES
ODU 300ep/hp/sp
QPSK 128QAM
Ethernet 200 /c 8xE1/DS1
II-2-46
Eclipse
ODU
IDUsp 4x
ODU 300sp/hp
4xE1
QPSK
IDUsp 16x
7 38
Eclipse
(
)
IDUsp
16x
ODU 300sp/hp
QPSK
IDUsp 4x
7 38
Eclipse
(
)
IDU300
8x
ODU 300ep/hp/sp
5 38
4
8E1/DS1
QPSK
16 QAM
Eclipse (ODU
300, RAC 30v1/v2,
DAC 4/16x, AUX)
/
IDU300
20x
ODU 300ep/hp/sp
5 38 2
4
20E1/DS1
QPSK
16 QAM
IDU 300 8x
INU, RAC 30v1/v2
Eclipse (ODU
300, RAC 30v1/v2,
DAC 4/16x, AUX)
/
II-2-47
2. Eclipse
IDU
ODU
IDU 300
20xV2
ODU 300ep/hp/sp
5 38
51
401
4xDS1
32xDS1
QPSK
128 QAM
20xE1/DS1)
IDU 155o
ODU 300ep/hp
5 38
1xSTM1/
OC3
Eclipse (ODU
300, RAC 30v3,
DAC 4/16x, AUX)
/
16/64/
128QAM
Eclipse (ODU
300, RAC 30v3,
RAC 3X, DAC
155o, AUX)
/
IDU ES
ODU 300ep/hp/sp
5 38
196
/
Ethernet
8xE1/DS1
QPSK
128 QAM
Ethernet 200
/c 8xE1/
DS1
Eclipse (ODU
300, RAC 30v3,
RAC 3X
DAC ES, DAC 4/
16x, AUX)
/
1.
2.
3.
/ INU/INUe.
E1/DS1 IDU
DAC 4x DAC 16x INU. , IDU,
AUX INU/INUe.
ODU 300ep hp; ODU 300sp ODU 300sp.
5 23 ODU 300ep, 7 38 ODU 300hp/sp.
RAC 30v3 STM1/OC3, 128 QAM ( 27,5-30 MHz).
II-2-48
Eclipse
100
. 2-12 100 :
.
ODU.
.
. 2-13 IDU/ODU
.
. 2-12. 100
IDU
ODU 100
QPSK 8x/16x E1
Eclipse (ODU 100,
RAC 10,
DAC 4/16x, AUX)
/
IDU 20x
ODU 100
QPSK 20 E1
Eclipse (ODU 100,
RAC 10,
DAC 4/16x, AUX)
/
IDU 8x
ODU1
ODU 100
8E1
QPSK
7 38
IDU 16x
ODU 100
2
IDU 16x, IDU 20x
INU, RAC 10, ODU 100
16xE1
QPSK
7 38
II-2-49
2. Eclipse
IDU
ODU1
ODU 100
20xE1
QPSK
7 38
1.
2.
II-2-50
Eclipse
Portal,
IDU/ODU.
:
Portal . 2-51
. 2-52
. 2-53
. 2-53
. 2-55
5.
Portal
IDU, IDUsp, (NMS) Ethernet
V.24 Portal. IDUsp Ethernet-.
Ethernet. Ethernet:
.
TCP/IP
LAN . IP-
. Ethernet
V.24
IDU,
V.24.
DHCP-, IDU
IP- Portal.
IDUsp
IDU. IP-
.
V.24. V.24 IP-
. IDU, V.24,
V.24.
II-2-51
2. Eclipse
Portal IV, 2.
Portal
() IDU, V.24
, V.24.
IP-,
Ethernet. DHCP.
, V.24
, IDUsp, Portal
Ethernet, , DHCP (Dynamic Host
Communications Protocol).
Ethernet,
V.24-. Ethernet
.
DHCP
, V.24,
DHCP c Portal ,
DHCP .
, V.24
DHCP-. DHCP-
,
DHCP- , DHCP- Portal.
IP- , c
Portal c LAN
IP- Portal.
, IDU
.
. 2-55.
DHCP-
DHCP- . 10-17, IV, 10.
II-2-52
Eclipse
IDU
. 3-8
IV.
IV.
.
:
( - - ),
; Helpdesk Data File (
)
II-2-53
2. Eclipse
IDUsp.
DHCP-
, .
IDU ,
IDUsp :
IP-:
169.254.1.1
255.255.0.0
DHCP:
169.254.2.1
169.254.254.255 255.255.0.0
:
.
, RIP OSPF
: /
, , .
. 2-55.
II-2-54
Eclipse
. 2-14 ,
IDU, V.24.
. 2-14.
IDU
ODU
IDU
:
IDU/
.
.
5
, 10
ODU
IDU
.
5
.
10
ODU
IDU
.
DHCP-.
DHCP-
. 2-24, IV,
2.
IDU
.
5
.
II-2-55
2. Eclipse
II-2-56
3.
Eclipse
INU INUe,
ODU. :
. 3-1
. 3-16
. 3-92
. 3-129
. 3-146
ODU Eclipse 4.
INU INUe
, -,
RAC/ODU. :
. 3-2
. 3-3
- . 3-4
: PDH SDH
. 3-6
: Ethernet
. 3-7
. 3-13
RAC/ODU . 3-13
II-3-1
3. Eclipse
INU INUe :
/
,
ODU
. 3-1. INU INUe
INU
3 1
/ 1
1 4
:
1
NCC
Fan
NPC
4
INUe
6 :
1 / 4
NCC
10
2 / 2
Fan
Fan
3 /
1 9
:
E1/DS1, E3/DS3, STM1/OC3, Ethernet
/
10 NPC
II-3-2
Eclipse
ODU
. 3-2 INU INUe.
. 3-2. INU INUe
INU/INUe
INU
1,2,3, 4 :
RAC, DAC AUX
1
NCC
Fan
4 NPC
: NP RAC, DAC, AUX
FAN NCC
, RAC
RAC/DAC 155oM
II-3-3
3. Eclipse
INU/INUe
INUe
1,2,3, 4,5,6 :
RAC, DAC AUX
NCC
Fan
1
4
Fan
7,8,9
: DAC AUX (
DAC 155oM AUX*)
10 :
NPC
FAN NCC
RAC
RAC/DAC 155oM
,
( )
NMS 1
6. DAC 155oM
AUX 7 9,
NMS.
-
,
TDM- -
, , NMS
.
TDM-
NxE1, NxDS1, NxE3, NxDS3 NxSTM1/
OC3. , Eclipse
NxE1, NxDS1, NxE3, NxDS3 NxSTM1/OC3.
:
100 x E1
128 x DS1
8 x E3
6 x DS3
2xSTM1/OC3
, , NxE1 STM1/
OC3, DAC STM1/OC3
E1 . , E1 STM1/
OC3 INU
II-3-4
Eclipse
SDH.
. 3-1
- ,
NCC. NPC
NCC TDM- .
. 3-1.
INU
RAC
RAC
DAC
AUX
RAC
NCC
II-3-5
3. Eclipse
: PDH SDH
INU INUe Eclipse ODU 300
( )
75xE1, 100xDS1, 8xE3, 6xDS3, 2xSTM1/OC3.
. 3-2
, , ODU 300
RAC 30/3X. . 3-3 . 3-7 .
ODU 100 QPSK, 4/
5xE1, 8/10xE1 16/20xE1 7, 14
28 .
. 13 .
. 3-2. RAC ODU 300 Eclipse
ODU 300 & RAC 30
4xE1
75xE1
4xDS1
100xDS1
E3
DS3
: QPSK
.: 3,5
4 xE3
4xE3
8xE3
3xDS3
3xDS3
6xDS3
STM1
STM1
2xSTM1
128QAM
30
QPSK
256QAM
40 / 50 / 55 / 56
II-3-6
Eclipse
- . 3-4,
" " . 3-3. RAC
30 30 ; RAC 3X 30 .
RAC
/
. 3-16.
, H. .
, ,
INU/NUe
,
.
. 3-3. PDH SDH
E11
100x
DS-1
128x
E3
8x
DS-3
6x
STM1/OC-3
1x, 2x
2x
1.
: Ethernet
Fast Ethernet- Eclipse (DAC ES)
E1 DS1.
Gigabit Ethernet- Eclipse (DAC GE)
E1, DS1 STM1/OC3.
Eclipse
.
II-3-7
3. Eclipse
:
Fast Ethernet . 3-8
Gigabit Ethernet . 3-9
Fast Ethernet
DAS ES, E1 DS1
Ethernet- 10/
100Base-T 150 /
( - ), 100 /
(100 / ).
, Ethernet-
() TDM-.
Ethernet- TDM-
.
NxE1, E1
(2,048 /) 150 / (75xE1 = 153.6 /) ,
130 / (63xE1 = 129 /) (DAC
155oM) .
NxDS1,
DS1 (1,544 /) 150 / (100xDS1 = 154,4 /)
, 130 / (84xDS1 = 129,7 /)
(DAC 155oM) .
. 3-3
NxE1, ,
,
Ethernet- PDH-.
. 3-4 NxDS1.
II-3-8
Eclipse
. 3-3. Ethernet
: NxE1
. 3-4. Ethernet
: NxDS1
Gigabit Ethernet
DAC GE, E1, DS1 STM/OC3
Ethernet 200 / (
E1/DS1), 300 / ( STM1/OC3).
II-3-9
3. Eclipse
II-3-10
Eclipse
. -
STM1/OC3. Ethernet 150 600 /c
. 300 / INU.
INU.
. 3-5. Ethernet 150
600 /
II-3-11
3. Eclipse
. 3-4 . 3-5
- 150 / (STM1) 300
/c (2xSTM1), RAC. RAC
30 30 ; RAC 3X -
40 56 .
. 3-4. , RAC - ETSI
RAC
150 /
27,5 / 28
128 QAM
RAC 30
40
64 QAM
RAC 3X
55 / 56
16 QAM
RAC 3X
55 / 56
128 QAM
RAC 3X
300 /
RAC
150 /
30
128 QAM
RAC 30
40
64 QAM
RAC 3X
50
16 QAM
RAC 3X
50
256 QAM
RAC 3X
300 /
DAC GE . 3-70.
II-3-12
Eclipse
RAC.
compact flash, NCC.
-
.
compact flash,
.
ETSI 10xE1, 6
RAC-.
16xDS1, 6 RAC-.
RAC.
.
, IV, 4.
RAC/ODU
. 3-6 ODU/RAC :
ODU: ODU 300ep, ODU 300hp, ODU 300sp ODU 100.
RAC: RAC 30, RAC 3X, RAC 40, RAC 10.
(Tx) ODU.
.
.
.
.
II-3-13
3. Eclipse
ODU 300ep
5 23
(Tx)
RAC1
RAC 303
41 751
4xDS1
100xDS1
QPSK
256 QAM
3,5 30
QPSK
256 QAM
40 56
QPSK
128 QAM
7 30
QPSK
256 QAM
40 56
QPSK
16 QAM
7 40
ODU 300sp
QPSK
7 28
ODU 100
ODU2
1/2/3/4xE3
1/2/3xDS3
1xSTM1/OC3
RAC 3X
64/75xE1
32/70/84/100xDS1
5/6/7/8xE3
3/4/5/6xDS3
1/2xSTM1/OC3
ODU 300hp
RAC 30
7 38
41 751
4xDS1
100xDS1
1/2/3/4xE3
1/2/3xDS3
1xSTM1/OC3
RAC 3X
64/75xE1
32/70/84/100xDS1
5/6/7/8xE3
3/4/5/6xDS3
1/2xSTM1/OC3
ODU 300sp
7 38
ODU 1004
7 38
1.
2.
3.
4.
RAC 303
RAC 10
4xE1 40xE1
4xDS1
32xDS1
4/5/8/10/16/20xE1
II-3-14
Eclipse
: PDH SDH . 3-6,
: Ethernet . 3-7.
II-3-15
3. Eclipse
,
.
:
. 3-16
NCC . 3-19
FAN . 3-22
RAC . 3-23
DAC . 3-45
AUX . 3-84
NPC . 3-90
. 3-7 .
.
. 3-7. Eclipse INU
NCC
NCC
INU/INUe.
, -48
. -,
.
FAN
FAN
FAN
INU - INUe, / 2007 FAN
2U FAN- 1U INU.
FAN ,
.
II-3-16
RAC
DAC
DAC
E1, E3, DS1, DS3, STM1/OC3 Ethernet:
DAC 4 41 DS1 .
DAC 16 161 DS1 .
DAC 3xE3/DS3 E3 DS3
.
DAC 3xE3/DS3M E3/DS3
( DAC 3xE3/DS3) 213
E3 234 /
(MPEG).
DAC 1x155o
STM1/OC3.
DAC 2x155o
STM1/OC3.
3. Eclipse
AUX
AUX
, NMS,
.
64 /c 19,2 /c.
NPC
NPC NCC
TDM- .
Eclipse
ODU INU, NCC, FAN, RAC DAC.
II-3-18
Eclipse
NCC
NCC INU/INUe. NCC
, ,
NPC. :
NCC . 3-19
NCC . 3-20
. 3-6. NCC
NCC
NCC :
TDM-
DC/DC
() -
-
II-3-19
3. Eclipse
NCC
. 3-7 NCC
. 3-8 . 3-20 .
PCB NCC :
25 ,
-48 Vdc.
CompactFlash PCB.
. 3-7. NCC
-48VDC
4 5
. 3-8. NCC
(2).
-48 .
NMS 10/100Base-T
RJ-45 Ethernet- .
Portal IP- INU/
INUe.
NMS INU/INUe Eclipse,
Harris Stratex
.
-.
Ethernet
NCCv2 .
- ,
- .
(
NMS RJ-45)
NCCv1 .
Ethernet
NCCv2 ,
Ethernet-.
( ), . ( ,
).
(
NMS RJ-45)
NCCv1 .
II-3-20
Eclipse
Maint V.24
RJ-45 Portal
V.24. IP-
, IP- NU/INUe .
(Test LED)
(Status LED)
INU/INUe.
INU/INUe /
, , .
(Status LED) :
INU/INUe
II-3-21
3. Eclipse
FAN
FAN INU, INUe, / 2007
FAN- 2U INU. FAN
.
.
- FAN .
FAN NCC
. ,
, .
.
( ) .
FAN.
/ 2007 IDCe ( 002)
(001) IDCe. IDCe ( INUe)
FAN 2U, FAN 1U.
. 3-8. FAN 1U
II-3-22
Eclipse
RAC
RAC
2STM1/OC3.
RAC 30, RAC 3X, RAC 10 RAC 40.
INU RAC,
- INUe.
RAC/ODU
.
RC .
.
INU/INUe
RAC (RAC 30, RAC 10, RAC 40)
:
RAC 30 RAC 3X . 3-23
RAC 10 . 3-40
RAC 40 . 3-41
RAC 30 RAC 3X
RAC 30 30 , RAC 3X
30 56 .
RAC 30
RAC 30 ODU 300.
ODU 300ep/hp RAC 30
751, 100DS1 1STM1/OC3
27,5/30 .
ODU 300sp RAC 30
401, 32DS1 27,5/30 .
RAC FEC1
.
RAC 30.
. 3-9.
, RAC 30 ,
RAC 30: RAC 30v3,
RAC 30 V2 RAC 30 V1.
RAC 30 FEC -. ,
/ ,
.
II-3-23
3. Eclipse
RAC 30
V1
V1, V2
;
2004.
001.
V2
002.
V3
V3, V21
RAC
30v3 003
.
1.
. RAC 30
RAC 30
RAC 30v3 RAC 30 V2
3.5 .
ETSI, . 3-10.
. 3-10. RAC 30v3 / RAC 30 V2
II-3-24
5xE1
QPSK
10xE1
QPSK 16QAM
20xE1
QPSK 16QAM
Eclipse
32xE1
64QAM
40xE1
16QAM
52xE1
32QAM
64xE1
64QAM
75xE1
128QAM
STM1
128QAM
RAC 30 V2
RAC 30 V2 / RAC 30v3
ETSI , .
3.5 RAC 30V2
, RAC
,
( Portal ).
RAC 30 V2 RAC 30 V1: RAC 30 V2
RAC 30.
RAC 30 V2 RAC 30 V2: RAC 30 V2
RAC 30.
II-3-25
3. Eclipse
RAC 30 V2,
PDH, RAC 30v3,
PDH.
RAC 30v3
PDH,
.
II-3-26
Eclipse
RAC 30 V2
PDH, RAC
30v3, 3.5 .
RAC 30 V2 RAC 30v3
PDH-
, . .
/ Portal
RAC 30 V2 RAC 30v3 ,
RAC 30 V2.
Portal lug-ins RAC 30v3
,
, .
, (
ETSI)
PDH,
(RAC 30 V2
PDH, RAC
30v3).
RAC 30v3
RAC
30v3
4xE1
QPSK
8xE1
QPSK 16QAM
16xE1
QPSK 16QAM
32xE1
16QAM
48xE1
32QAM
64xE1
128QAM
RAC 30v3 RAC 30 V2,
Harris Stratex Networks
3.5 .
,
, RAC 30v3,
, RAC 30v3, , RAC 30v3
. ,
RAC 30 V2, RAC 30v3,
II-3-27
3. Eclipse
3.5
, .
. V1-V2 V2-V2
.
RAC 30 V2
-
:
3.4,
.
10- () ,
3.3 .
RAC 30,
, RAC 30
.
RAC 30 V2 .
RAC 30 V2, RAC 30v3 INU/INUe,
RAC 30v3.
RAC 30v3
, RAC 30 V2
RAC 30v3.
RAC :
RAC 30 V1 RAC 30v3.
RAC 30 V1 RAC 30 V2 ,
RAC 30v3, RAC 30 V2, RAC 30v3,
RAC 30v3.
RAC
Portal,
RAC:
RAC
RAC 30 V1 V2
RAC 30v3,
RAC 30 V1 ( ), , Portal
"Local and remote modem profiles do not
match" ( ).
II-3-28
Eclipse
RAC
,
, RAC ,
, .
RAC RAC 30 V1 IDU 300 20x V1,
,
, .
"Unsupported configuration"
( ) "This RAC may be
incompatible with the RAC at the other end of the link" ( RAC
RAC ).
Event Browser.
RAC
RAC 30 V1 ( IDU 300 20x V1)
RAC 30v3 .
, RAC
, Portal
"Local and remote modem profiles do not match"
( ).
RAC 30 V1 IDU 300 20x V1 ,
,
"Unsupported configuration" ( )
"This RAC may be incompatible with the RAC at the other end
of the link" ( RAC RAC
).
RAC 30v3 ( IDU 300 20x V2, IDU ES IDU 155o)
, - .
RAC 30v3 RAC 30 V2 Plug-ins,
Portal>Edit>Preferences
,
RAC 30 V2 RAC
30 RAC 30v3.
/.
RAC 30 V2,
RAC 30v3,
, ,
RAC 30v3.
II-3-29
3. Eclipse
RAC 3X
RAC 3X c RAC 30
ODU 300
40 56 , :
64/75xE1, 5/6/7/8xE3, 1/2xSTM1
32/70/84/100xDS1, 3/4/5/6xDS3, 1/2xOC3
RAC 3X FEC - ,
.
:
RAC
. 3-9. RAC 30V2
II-3-30
Eclipse
. 3-10. RAC 3X
/
QPSK, 16QAM, 32QAM, 64QAM, 128QAM
256QAM.
. 3-11 . 3-31
ETSI, RAC 30 RAC 3X.
. 3-12 . 3-33
(ANSI)
. 3-11. ETSI RAC 30 RAC 3X
4xE1 1
QPSK
5xE1
QPSK
8xE1 1
13.75 / 14
QPSK
10xE1
13.75 / 14
QPSK
16xE1 1, 1xE3
27,5 / 28
QPSK
II-3-31
3. Eclipse
20xE1
27,5 / 28
QPSK
4xE1 1
3,5
16QAM
5xE1
3,5
16QAM
8xE1 1
16QAM
10xE1
16QAM
16xE1 1, 1xE3
13.75 / 14
16 QAM
16xE1 1, 1xE3
64 QAM
20xE1
13.75 / 14
16 QAM
32xE1 1, 2xE3
27,5 / 28
16 QAM
32xE1, 2xE3
13.75 / 14
64 QAM
40xE1
27,5 / 28
16 QAM
48xE1 1, 3xE3
27,5 / 28
32 QAM
52xE1
27,5 / 28
32 QAM
64xE1
27,5 / 28
64 QAM
55 / 56
16 QAM
40
64 QAM
27,5 / 28
128 QAM
8xE3, 2xSTM1 2
55 / 56
128 QAM
1.
2.
3.
II-3-32
RAC 30v3.
/ RAC 3X
/ RAC 30 RAC
3X. STM1.
Eclipse
. 3-12. ANSI
RAC 30 RAC 3X
4xDS1
2.5
16 QAM
8xDS1
10
QPSK
8xDS1
16 QAM
8xDS1
3,75
32 QAM
16xDS1
20
QPSK
16xDS1
10
16 QAM
16xDS1
128 QAM
28xDS1/1xDS3
30
QPSK
28xDS1/1xDS3
20
16 QAM
28xDS1/1xDS3
10
64 QAM
32xDS1 1
40
QPSK
32xDS1
20
16 QAM
56xDS1/2xDS3
20
64 QAM
70xDS1 1
40
16 QAM
70xDS1
30
32 QAM
50
16 QAM
84xDS1/3xDS3 1
40
32 QAM
84xDS1/3xDS3
84xDS1/3xDS3
30
64 QAM
50
16 QAM
100xDS1 1
40
32 QAM
100xDS1
100xDS1
30
128 QAM
40
64 QAM
5xDS3 1
50
64 QAM
6xDS3 1
50
256 QAM
4xDS3
II-3-33
3. Eclipse
1xOC3 1
50
16 QAM
1xOC3 1
40
64 QAM
1xOC3 2
30
128 QAM
2xOC3 1
50
256 QAM
1.
2.
II-3-34
/ RAC 3X
/ RAC 30 RAC
3X. STM1.
Eclipse
.
. 3-13. RAC 30 V2: ETSI
RAC 30 V2
4E1,7M,QPSK
1.66
4E1,3.5M,16Q
1.66
5E1,7M,QPSK
1.4
5E1,3.5M,16Q
1.41
8E1,14M,QPSK
1.39
8E1,7M,16Q
1.4
10E1,14M,QPSK
1.15
10E1,7M,16Q
1.15
16E1,28M,QPSK
0.79
16E1,14M,16Q
0.79
16E1,7M,64Q
0.58
20E1,28M,QPSK
0.68
20E1,14M,16Q
0.68
32E1,28M,16Q
0.5
32E1,14M,64Q
0.39
40E1,28M,16Q
0.44
48E1,28M,32Q
0.39
52E1,28M,32Q
0.38
64E1,28M,64Q
0.29
64E1,28M,128Q
0.35
75E1,28M,128Q
0.32
1E3,28M,QPSK
0.4
1E3,14M,16Q
0.4
II-3-35
3. Eclipse
RAC 30 V2
2E3,28M,16Q
0.32
3E3,28M,32Q
0.23
4E3,28M,128Q
0.18
1STM1,28M,128Q
0.19
RAC 30v3
5E1,7M,QPSK
1.06
10E1,14M,QPSK
0.63
10E1,7M,16Q
0.63
20E1,28M,QPSK
0.41
20E1,14M,16Q
0.42
40E1,28M,16Q
0.3
52E1,28M,32Q
0.27
64E1,28M,64Q
0.26
75E1,28M,128Q
0.25
1STM-1,28M,128Q
0.125
II-3-36
RAC 3X
64E1,56M,16Q
0.34
75E1,56M,16Q
0.31
1STM-1,56M,16Q
0.19
1STM-1,40M,64Q
0.19
1STM-1,28M,128Q
0.19
2STM-1,56M,128Q
0.125
2STM-1,50M,256Q
0.125
Eclipse
RAC 30 V2
4DS1,5M,QPSK
2.2
4DS1,2.5M,16Q
2.2
8DS1,10M,QPSK
1.85
8DS1,5M,16Q
1.85
8DS1,3.75M,32Q
1.85
16DS1,20M,QPSK
1.1
16DS1,10M,16Q
1.1
16DS1,5M,128Q
1.1
28DS1,30M,QPSK
0.75
28DS1,20M,16Q
0.55
28DS1,10M,64Q
0.55
32DS1,20M,16Q
0.55
56DS1,30M,32Q
0.4
56DS1,20M,64Q
0.4
70DS1,30M,32Q
0.45
84DS1,30M,64Q
0.35
100DS1,30M,128Q
0.4
1DS3,30M,QPSK
0.3
1DS3,20M,16Q
0.31
1DS3,10M,64Q
0.31
*2DS3,20M,64Q
0.17
3DS3,30M,64Q
0.12
1OC3,30M,128Q
0.19
II-3-37
3. Eclipse
II-3-38
RAC 3X
32DS1,40M,QPSK
0.65
70DS1,40M,16Q
0.45
84DS1,50M,16Q
0.45
84DS1,40M,32Q
0.45
100DS1,50M,16Q
0.4
100DS1,40M,32Q
0.4
1OC3,50M,16Q
0.19
1OC3,40M,64Q
0.19
1OC3,30M,128Q
0.19
2OC3,50M,256Q
0.125
Eclipse
RAC
. 3-11 . . 3-18
.
. 3-11. RAC 30 (RAC 30v2)
II-3-39
3. Eclipse
(2).
(Online LED)
INU
ODU
RAC ,
"". RAC ,
, ,
.
(Status
LED)
3
1.
2.
3.
ODU
RAC
1
ODU
INU
/ 2
3 RAC ODU
- SMA- ODU
, ,
RAC , - .
, ,
/ .
, ,
.
RAC 10
RAC 10 , RAC 30.
RAC 10 ODU 1002,
4x, 5x, 8x, 10x, 16x, 20xE1,
II-3-40
Eclipse
QPSK.
. 3-19.
RAC 10
4x, 5xE1
8x, 10xE1
13.75 / 14
16x, 20xE1
27,5 / 28
RAC 40
XPIC
/ , RAC 40 RAC 30.
RAC 40 ODU 300ep ODU 300hp
27,5/28 (ETSI) 30 (ANSI)
:
64x, 75xE1
70x, 84x, 100xDS1
STM1/OC3
:
II-3-41
3. Eclipse
. 3-13 . . 3-20
.
II-3-42
Eclipse
. 3-13. RAC 40
. 3-20. RAC 40
(2).
(Online LED)
INU
ODU
RAC , "".
RAC ,
,
,
.
(Status
LED)
RAC 1
ODU
INU
/ 2
3 RAC ODU
/
XPIC.
SMB- - XPIC
ODU
- SMA- ODU
II-3-43
3. Eclipse
1.
2.
3.
, ,
RAC , - .
, ,
/ .
, ,
.
II-3-44
Eclipse
DAC
DAC
.
DAC
. :
DAC 4x . 3-46
DAC 16x . 3-47
DAC 3xE3/DS3 . 3-49
DAC 3xE3/DS3M . 3-51
DAC 1x155o DAC 2x155o . 3-53
DAC 155oM . 3-56
DAC 2x155e . 3-59
DAC ES . 3-61
DAC GE . 3-70
DAC
INU INUe, c c INUe.
DC .
DAC .
DAC 3xE3/DS3, DAC 3xE3/DS3M, DAC 1x155o, DAC 2x155o,
DAC 155oM, DAC 2x155e.
: DAC 4x, DAC 16x DAC Ethernet-.
DAC :
/DAC . 3-115
, IV, 8.
C. .
E.
.
DAC IV,
15.
PRBS- BER-
PRBS IV, 15.
AIS/PRBS15 LOS
( )
AIS PRBS IV, 15.
II-3-45
3. Eclipse
DAC 4x
DAC 4 41 DS1 .
75 120
E1.
DS1 AMI,
B8ZS. 100 .
RJ-45, :
RJ-45 - BNC male.
, -, RJ-45 - RJ-45.
, RJ-45 - .
. 3-14 . . 3-21
.
. 3-14. DAC 4x
1
DAC 4x
Status
Trib 1-4
. 3-21. DAC 4x
(2).
(Status LED)
II-3-46
INU
/
1
:
/ LOS
Eclipse
4 RJ-45
1.
, ,
/ .
DAC 16x
DAC 16 161 16xDS1 .
75 120
E1 .
DS1
AMI, B8ZS. 100 .
Mini RJ-21 ,
:
Mini RJ-21 BNC le, .
.
Mini RJ-21 RJ-45, , -.
.
, Mini RJ-21 .
.
II-3-47
3. Eclipse
(2).
(Status LED)
II-3-48
INU
Eclipse
3, 4
1.
/
1
:
/ LOS
RJ-21
, ,
/ .
DAC 3xE3/DS3
DAC 3xE3/DS3 E3 DS3
. INU/INUe
E3 DS3 .
75 , ,
mini BNC female.
:
Mini BNC male mini BNC male; .
Mini BNC male BNC male; .
DAC 3xE3/DS3 INU/
INUe.
, DAC ( ),
DAC 3xE3/DS3 Y-
BNC male.
II-3-49
3. Eclipse
(2).
(Status LED)
II-3-50
INU
Eclipse
/
1
:
/ LOS
1.
, ,
/ .
DAC 3xE3/DS3M
DAC 3xE3/DS3M :
3xE3/DS3.
E13
1x/2x E3 / o 1.
( M13 Eclipse).
(unframed) 1x/2xE3 34 /.
:
DAC 3xE3/DS.
3E1/DS1 DAC 3xE3/DS3.
o E3 DS3.
E13,
E3 (Tx/Rx 1 Tx/Rx 2) E1
, 16xE1, G.703,
G.742 G.751.
E13 , ,
E3 E13
.
E1 Eclipse.
II-3-51
3. Eclipse
M13,
DS3 (Tx/Rx 1 Tx/Rx 2) DS1
, 28xDS1, T1.102
T1.107. M13
, , DS3
M13 .
DS1
Eclipse.
E3- ATM (, MPEG2)
E3. E3 (Tx/Rx 1 Tx/Rx
2) 34,368 /,
171 NxE1 Eclipse.
E1 Eclipse.
Super-PDH Eclipse
DAC 3xE3/DS3M E13 M13.
NMS 64 /
(Tx) (Rx) NMS 128
/c.
AUX.
E3 DS3
75 , mini BNC
female.
:
Mini BNC male mini BNC male; .
Mini BNC male BNC male; .
DAC 3xE3/DS3M INU/
INUe. ( INUe , NMS
, 1 6).
, DAC ( ),
DAC 3xE3/DS3M Y-
BNC male.
. 3-19 DAC 3xE3/DS3.
. 3-24 .
. 3-19. DAC 3xE3/DS3M
II-3-52
Eclipse
(2).
(Online LED)
(Status LED)
INU
DAC
INU
/ 1
:
/ LOS
1.
, ,
/ .
II-3-53
3. Eclipse
.
SDH SONET:
, ;
/
. ADM-ADM,
AMD
.
- (
) DAC 1x155o DAC 2x155o,
2 Eclipse (
DAC-DAC).
(RAC-RAC)
DAC.
DAC 1x155o DAC 2x 155o
STM1/OC3.
SC-, - SC, FC .
SC-SC.
-31 ( ) -7
( ).
: . -15 . -8 .
SDH Binary Scrambled NRZ
( NRZ ( ) ).
, DAC ( ),
DAC 3xE3/DS3 Y-
(Tx) (Rx) SC-.
II-3-54
Eclipse
(2).
(Status LED)
INU
/
1
II-3-55
3. Eclipse
3
1.
:
/ LOS
SC-
, ,
/ .
DAC 155oM
DAC155oM ;
SDH/SONET
SDH SONET.
DAC 155oM STM1/OC3,
155 /c f/ o Eclipse,
NxE1 NxDS1.
VC3 VC4 STM1.
SONET .
SDH VC3: VC3 STM1
, 21xVC12 28xVC11.
VC12 1xE1, VC11 - 1DS1.
SDH VC4: VC4
63xVC12 84xDS1 STM1. VC12
1xE1, VC11 - 1DS1.
SONET STS1: STS1
SONET, 28xVT1 21xVT2.
VT1 1xDS1, VT2 - 1E1.
(TVT).
, ,
Ethernet-, TVT.
.
NMS Eclipse MSOH RSOH,
o INU.
:
Eclipse Super-PDH .
II-3-56
Eclipse
LC SFP
( -),
- SC FC .
LC-LC.
, DAC ( ),
DAC 1x155oM Y-
(Tx) (Rx) LC-.
INUe, NMS DAC
155oM, 1 6.
NMS ( NMS DAC 155oM), DAC 155oM
7 9.
. 3-23 DAC 1x155oM.
. 3-26 .
II-3-57
3. Eclipse
(2).
(Online LED)
(Status
LED)
3
1.
INU
DAC
INU
/ 1
: /
LOS
LC-
, ,
/ .
, ,
LC . ; Short
Range Long Range.
1 (Class 1).
II-3-58
Eclipse
DAC 2x155e
DAC 2x155e STM1 155 /c
.
, 75 , BNC female.
SDH SONET:
, ;
/
. ADM-ADM, AMD
.
- (
) DAC 2x155e,
2 Eclipse (
DAC-DAC).
(RAC-RAC)
DAC.
BNC male
BNC male; .
II-3-59
3. Eclipse
II-3-60
Eclipse
(2).
(Status LED)
3
1.
INU
/
1
:
/ LOS
, ,
/ .
DAC ES
DAC ES - Fast Ethernet.
:
DAC ES . 3-62
. 3-64
. 3-66
. 3-66
Priority Mapping ( ) . 3-67
Flow Control ( ) . 3-68
Disable Address Learning ( ) . 3-68
Maximum Frame Size ( ) . 3-69
II-3-61
3. Eclipse
DAC ES
DAC ES Fast Ethernet .
10/100Base-T
Eclipse,
1,5 /c 2 /
100 / .
DAC ES:
;
:
, VLAN () ;
Nx1,5 /c Nx2 /c;
;
Ethernet E1/DS1 PDH,
Ethernet.
QoS
(802.1p);
- 802.3;
1536 ;
, RMON ;
DAC GE ( 3.6).
II-3-62
Eclipse
. 3-27. DAC ES
1
Ethernet
2
3
Port 4
C1
Ethernet
L2+-
(
C2
QoS)
FPGA
. 3-28. - DAC ES
RJ-45
. 3-28
DAC ES - DAC ES 100 / (48xE1)
RAC 30V2.
II-3-63
3. Eclipse
. 3-28.
100 /.
64
260
72 /
128
270
82 /
256
290
88 /
512
330
93 /
1024
405
95 /
1518
480
95,5 /
DAC ES : ,
VLAN:
, ;
.
( 1 4)
(C1, C2).
. 3-29.
C1 C2
. C1 C2
,
RAC ( RAC / DAC 155oM).
, Eclipse,
, - .
, P1-C1
P1.
/ P1, P2, P3
C2.
II-3-64
Eclipse
. 3-30.
. , ,
Ethernet,
RSTP .
VLAN
VLAN -
. VLAN 1 , ,
1
. 2, 3 4 C2
VLAN- (VLAN- 2, 3 4) VLAN ,
.
. 3-31. VLAN
II-3-65
3. Eclipse
(1, 2) :
NxE1 NxDS1,
.
,
E1 DS1, C1 / C2:
NxE1,
48xE1 Ethernet 98,3 /.
INU/INUe ,
3 (48xE1 48xE1
).
,
RAC 30/40 751 (150 /c).
NxDS1,
64DS1, Ethernet
98,8 / (64 x 1,544 /c).
DAC ES 112,
NxDS1 56DS1 (86,4 /c); 56DS1 56DS1
.
,
RAC 30/40 100DS1 (154 /c).
:
Enabled ()
.
Name ()
.
Connection Type and Speed ( )
, ,
3
/ ,
RSTP.
II-3-66
Eclipse
10 / 100 /.
, DAC ES ,
.
Interface Cable Type ( )
; Mdi MdiX ( -
).
Priority ()
: ,
, .
, .
8:4:2:1,
8 .
Port Up ( )
, Ethernet.
.
Resolved ()
, DAC ES
Ethernet- , ,
, / Mdi/MdiX.
, .
Priority Mapping ( )
. .
Port Default ( )
(
- " " ).
VLAN 802.1p
DiffServ IP.
802.1p ,
VLAN 802.1p.
(2- ) .
, Port Default
.
II-3-67
3. Eclipse
DiffServ ,
Type of Service DiffServ IP.
63 (2- )
. ,
Port Default .
802.1p-then-DiffServ (802.1p--DiffServ)
, VLAN 802.1p,
Type of Service DiffServ. ,
Port Default .
DiffServ-then-802.1p (DiffServ--802.1p)
, Type of Service DiffServ
IP, VLAN 802.1p. ,
Port Default .
Flow Control ( )
Flow Control ( )
. PAUSE
IEEE 802.3x,
, ,
.
,
,
, .
, (flow control)
, ,
, DAC ES
(flow control).
Disable Address Learning ( )
Address Learning ( )
Ethernet- .
Address Learning
, Ethernet-
RSTP-;
Eclipse.
, DAC ES,
RSTP- ,
DAC ES . ,
Ethernet,
Ethernet- , DAC ES
/ ,
/
II-3-68
Eclipse
, 5 .
Maximum Frame Size ( )
Maximum Frame Size ( )
,
,
().
- 64 , - 1536 .
Portal
Ethernet . DAC ES
:
/.
(Rx)
(Tx) .
(Rx)
(Tx), .
.
RMON .
.
IV, 15:
DAC ES
Status
II-3-69
3. Eclipse
(2).
(Status
LED)
1.
2.
INU
/
1
RJ-45
RJ-45 Ports 1 to 4
10/100Base-T. ,
Ethernet /. RJ-45
(Activity LED) (Connection LED):
Ethernet
. ,
Ethernet-.
.
Ethernet
(Activity LED). ,
Ethernet-. ( ),
. ( ,
).
, ,
/ .
, - .
DAC GE
DAC GE Gig-Ethernet-.
:
DAC GE . 3-71
DAC GE . 3-73
DAC GE . 3-76
DAC GE . 3-77
II-3-70
Eclipse
DAC GE . 3-78
DAC GE . 3-78
Address Learning DAC GE . 3-78
DAC GE . 3-79
. 3-79
RWPR . 3-80
VLAN. . 3-81
Ethernet . 3-82
DAC GE. . 3-82
DAC GE
Harris Stratex Networks': DAC GE.
, 2006
DAC GE ( 3.6)
E1 DS1,
L1 .
DAC GE
DAC GE LAN Gigabit
Ethernet. 10/100/1000Base-T
SFP 1000Base-LX
Eclipse.
DAC GE:
, 360
2000 ;
:
, VLAN () ;
Nx1.5 /, Nx2 /
Nx150 /;
;
Ethernet-
E1/DS1 PDH,
Ethernet-.
QoS
(802.1p);
VLAN ( VID).
QinQ (802.3ac);
II-3-71
3. Eclipse
II-3-72
Eclipse
Ethernet-
MAC-
/, .
( ),
QoS, VLAN.
Ethernet,
, :
E1 DS1 :
100 / (1 2), 200 /
, .
1,5 / 2 /.
STM1 :
150 / 1 2
300 / 1 2
150 / 1, 2
1
RJ-45
10/100/1000Base-T
2
3
SFP
1000Base-LX
. 3-34. DAC GE
Ethernet
C1
QoS
RSTP
C2
FPGA
uP
:
/. , 150 / 300 /
1518 152
308 / .
DAC GE
DAC GE , ,
VLAN, - -
L2.
RWPR - RSTP, ,
VLAN-,
.
II-3-73
3. Eclipse
(layer
2), .
(Layer 2)
(Layer 1) . 3-79.
, .
.
LAN- ( 1 4)
(C1, C2).
. 3-35.
C1 C2 . C1 C2
, DAC GE
,
.
1 2
1 2
P1 P4
.
XPOL
(2xRAC 30) XPIC (2xRAC 40).
. 3-36. 1 2
1, 2 1
1 2 P1
P2 P4.
,
II-3-74
Eclipse
( ). ,
, P2,
P3 P4 .
. 3-37. 1, 2 1
1, 2 4
,
.
1 2 P4
P1 P3.
,
( ). ,
LAN, P1,
P2 P3 .
. 3-38. 1, 2 4
, P1-C1
1.
P1, P2, P3 C2 .
. 3-39.
, ,
II-3-75
3. Eclipse
, 1 , C2 - .
VLAN
VLAN . LAN 1
, , 1
. 2, 3 4,
() (VLAN 2, 3 4) C2,
,
.
. 3-40. VLAN
, ,
, 1 , C2 - .
DAC GE
(C1, C2):
.
4
:
4
RAC DAC 155oM,
L1
( ) .
II-3-76
Eclipse
.
Name ()
.
Connection Type and Speed ( )
. , DAC GE
, .
Interface Cable Type ( )
; Mdi MdiX (
- ).
Priority ()
: , -, - .
,
. , ,
,
, - .
Port Up ( )
, Ethernet-.
.
Resolved ()
, DAC GE
Ethernet- , ,
5
DS1, 128DS1.
II-3-77
3. Eclipse
, / Mdi/MdiX.
, .
DAC GE
. .
Port default ( ).
.
DAC GE .
802.1p ,
VLAN 802.1p.
(2- ) .
.
DiffServ ,
Type of Service DiffServ IP.
63 (2- )
. .
No priority ( ). .
DAC GE
PAUSE
IEEE 802.3x,
, ,
.
,
,
, .
,
, , ,
, DAC GE ,
.
Address Learning DAC GE
Address Learning ( )
Ethernet-
. Address Learning
,
Ethernet- RSTP.
,
DAC GE, RSTP
, DAC GE .
II-3-78
Eclipse
, Ethernet
Ethernet-
, DAC GE
/ ,
/ ,
5 .
DAC GE
Maximum Frame Size ( )
,
,
(). DAC GE
9600 ; 64 9600 .
,
.
.
,
. ,
,
,
.
DAC GE Eclipse
, 2 (L2) 1 (L1):
L2 MAC-
/ MAC/LLC
Ethernet,
.
, , ,
, .
, MAC- /
, ,
, ( 10)
, ,
.
,
600+ /.
(L2)
DAC GE Operational Mode ( DAC GE).
II-3-79
3. Eclipse
L1 -
INU/INUe,
DAC GE
.
Ethernet
( ), ,
Ethernet
.
.
L2,
,
. ,
, ,
,
.
,
.
DAC GE
L1.
L1 L2 .
, DAC GE
, L1
,
L2 DAC GE.
,
, L1,
( )
.
L2.
. 7-88, IV, 7.
RWPR
DAC GE RSTP RWPR RSTP.
RWPRTM (Resilient Wireless Packet Ring)
(RFD),
Harris Stratex Networks, DAC
GE RSTP. RFD ,
RSTP- / Ethernet,
2 5
II-3-80
Eclipse
, 50 .
/ - RSTP,
, ,
RSTP ,
.
RWPR DAC GE,
IV, 7.
RWPR
Harris Stratex Networks: DAC GE.
VLAN.
DAC GE 802.1q :
Do Nothing ( ).
ID VLAN.
802.1p Q in Q (Q 802.1p Q Q). VLAN
, . VLAN
; .
Tag and Remove ( ).
VLAN; .
VLAN; ,
, .
Add Tag ( ).
VLAN QoS,
. VLAN
ID .
Tag and Remove All ( ).
VLAN;
. ID VLAN.
Drop Non-VLAN Frames ( VLAN ).
VLAN . , ,
VLAN, .
II-3-81
3. Eclipse
Ethernet
Portal
Ethernet . DAC GE
:
/.
(Rx)
(Tx), .
(Rx) (Tx),
.
.
RMON .
.
IV, 15:
Performance DAC GE
History: Ethernet
DAC GE.
. 3-32 DAC GE. . 3-29
.
. 3-41. DAC GE.
. 3-30. DAC GE
(2).
(Status
LED)
II-3-82
Eclipse
4
1.
2.
INU
/
1
RJ-45
RJ-45 Ports 1 to 3
10/100Base-T. ,
Ethernet /. RJ-45
(Activity LED) (Connection LED):
Ethernet
(Activity LED). ,
Ethernet-. ( ),
. ( ,
).
Ethernet
. ,
Ethernet-.
.
SFP
-
1000Base-LX. LC.
, ,
/ .
, - .
II-3-83
3. Eclipse
AUX
AUX /
(I/O) .
* AUX INU; - INUe.
INUe, AUX 1 6,
NMS. NMS AUX ,
AUX 7 9.
:
. 3-84
/ . 3-86
AUX . 3-89
. 3-42. AUX
.
Portal 64 /
19 /.
II-3-84
Eclipse
64/
TIA/EIA-422 / V.11 c
.
(
) ( ).
,
(
).
TIA/
EIA-562 ( RS-232 / V.24, DB-15,
DB-9)
: 1200, 2400, 4800,
9600, 19200 / - :
1 , 7 , 1 , 2
1 , 8 , 1 , 1
1 , 8 , , 2
1 , 9 , , 1
1 , 7 , 1 , 1
1 , 7 , , 2
1 , 8 , , 1
:
. 3-85
NMS . 3-85
. 3-86
:
NMS ( )
Eclipse.
NMS Eclipse
Eclipse.
NMS
,
NMS:
Data ()
II-3-85
3. Eclipse
() 64 /
(RAC DAC 155oM).
V.24/RS-232,
V.11/RS-422 .
INU-INU NMS .
,
RA DAC 155oM. ( AUX
).
,
AUX.
NMS
NMS Eclipse
/ Eclipse,
AUX.
V.11/RS-422, 64
/.
RAC 30, RAC 3X RAC 40,
512 /, 128
/c NMS.
384 /c (6x64 /c) .
NMS. ,
NMS; , NMS 448 /c;
- 384 /c NMS, , 128 /c.
RAC 10,
192 /c, ,
.
DAC 155oM,
512 /c, , NMS
MSOH (Multiplexer Section Overhead). NMS
RSOH (Regenerator Section Overhead), 192 /
c, ,
.
/
AUX 6 TTL- 4
C. :
II-3-86
Eclipse
2 TTL- 4
4 TTL- 2
6 TTL- ( )
:
. 3-87
. 3-87
. 3-88
TTL- ,
, .
, , ,
. 1 .
.
.
TTL- : 2 , 0,8 - .
( )
48.
.
,
/.
.
:
250
60
: ,
,
.
60 ,
II-3-87
3. Eclipse
SELV.
30
:
AUX
.
.
IP-
, AUX.
II-3-88
Eclipse
AUX
. 3-43. AUX
. 3-31. AUX
(2).
(Status
LED)
INU
/
1
DSUB 15 /
E.
DSUB 26 AUX
E.
1.
2.
, ,
/ .
, .
II-3-89
3. Eclipse
NPC
NPC NCC
TDM- ( )
. INU/INUe NPC.
NPC . /
TDM-
. 100 ,
.
.
NCC , NPC
. .
NCC,
TDM- NPC,
NCC .
NCC / NPC,
System/Controls.
NCC. NPC,
NPC ,
NCC.
. 3-44. NPC
II-3-90
Eclipse
NPC ( ,
NCC). 4 INU 10
INUe.
INU/INUe
NCC; NPC , .
. 3-45
. 3-32
. 3-45. NPC
Protect
NPC
-48VDC
Status
. 3-32. NPC
(2).
(Protect LED)
(Status LED)
-48 . .
(
TDM-)
INU/INUe
2-
II-3-91
3. Eclipse
.
:
. 3-92
. 3-95
. 3-96
. 3-98
Super PDH . 3-98
Super PDH . 3-100
1+1 . 3-105
XPIC . 3-108
Ethernet- . 3-108
/DAC . 3-115
. 3-117
NCC NPC . 3-128
G.
Eclipse ,
, NCC.
RAC ODU
, ,
.
,
,
.
()
() .
/ ,
.
II-3-92
Eclipse
.
. .
.
, ,
, ,
.
.
Eclipse ,
- ,
.
Eclipse:
6
. 3-96
RAC / ODU
RAC 30 RAC 3X:
. (Rx)
; (Tx)
.
.
.
RAC 40:
(
). (Rx) .
(Tx) .
(
), V .
.
RAC 107:
- .
Harris Stratex Networks
.
7 RAC 10 V2 V1; V1 . V1 001;
V2 - 002.
II-3-93
3. Eclipse
2x (RAC 30 / RAC 3X +
ODU 300)
2x (RAC 40 / RAC 3X +
ODU 300)
(
XPIC)
(
XPIC)
1.
RAC 30v3
5xE1, 4xDS1 8xDS1.
DAC E3/DS3 STM1/OC3
.
DAC:
2xDAC 3xE3/DS3
2xDAC 3xE3/DS3M
2xDAC 155o
2xDAC 2x155o
2xDAC 2x155e
2xDAC 155oM
II-3-94
Eclipse
.
DAC 155oM, (Tx) (Rx)
.
, (Tx) (Rx)
, (Tx) (Rx),
, .
NCC
NPC NCC:
.
.
NPC NPC
. 3-90.
INU ,
. INUe
.
RAC ODU
. ,
ODU ,
.
.
()
RAC 30, RAC 3X, RAC 40
RAC 10v2. RAC 10v1
,
.
" "
. .
. 3-118.
,
:
3,5/3,5
.
1,6/6,4 .
II-3-95
3. Eclipse
. 7-20, IV, 7.
-
,
.
Eclipse:
. 3-34 ;
- .
RAC (RAC 30 RAC 3X) INUe.
,
,
.
. 3-34.
. 3-46 -
,
.
F1/F1 F2/F28.
.
II-3-96
Eclipse
INUe.
- ,
INUe;
- (
) .
. 3-46. ( )
(Tx) (Rx)
,
.
(-).
RAC (RAC 30 RAC
3X),
RAC,
RAC 30, RAC 3X RAC 10.
; / .
,
INUe .
-
.
( /
/ )
.
-
(Rx) ,
(Tx) .
II-3-97
3. Eclipse
-
.
()
(Rx) ,
-
. .
.
:
IV Portal,
8.
Harris Stratex Networks:
Eclipse.
Eclipse NxE1
NxDS1.
Eclipse E3/DS3 STM1/OC3. ,
,
/.
Eclipse RSTP Ethernet-
, DAC GE GigE.
:
Super PDH . 3-98
Super PDH . 3-100
1+1 . 3-105
XPIC . 3-108
Ethernet- . 3-108
H. .
Super PDH
Eclipse PDH
75E1 100DS1,
INU/INUe.
(INU/INUe) RAC ODU,
/. ,
, .
" " (North Gateway)
II-3-98
Eclipse
, , ,
.
, ,
. ( ).
, DAC 155oM.
,
(, ).
/
;
.
II-3-99
3. Eclipse
Super PDH
:
. 3-100
. 3-102
. 3-102
-. . 3-104
. 3-104
. 3-105
Ethernet Ethernet-
. 3-108
. 3-47 ,
super-PDH. 64xE1,
. ,
E1, .
,
.
. 3-47.
Rx Tx
Rx Tx
A
64xE1
84xDS1
( )
Rx
Tx
Tx
Rx
II-3-100
Eclipse
,
E1, ''
,
. . . 3-48.
.
. 3-48.
Rx Tx
Rx Tx
A
()
Tx
Rx
Rx
Tx
,
D
, ,
, .
,
. , (),
, ,
( ).
,
,
- Error-Free Timer ( 5 ),
- Delay Ring Unwrap
Timer, (
).
. 3-126.
: .
II-3-101
3. Eclipse
. 3-124 .
, , .
,
;
,
. . . 3-35.
, Eclipse,
.
. 3-35. RAC 30
16xE1
32xE1
75xE1
0,7
0,35
0,17
16
11,2
5,6
2,8
, , (
), ,
.
, "" (
), ,
,
. . . 3-49.
:
A .
, / , .
, E, .
:
B D.
, B D, .
, / , .
II-3-102
Eclipse
. 3-49.
A
II-3-103
3. Eclipse
-.
"-" . 3-50.
, ,
, .
.
. 3-50.
"-"
32xE1
G
B
32xE1 :
64xE1 :
64xE1
32xE1 .
32xE1 -
1
-
D
C, D E
- 321,
321.
INUe, .
II-3-104
Eclipse
. 3-51.
32xE1
64xE1
Eclipse
A
B
TDM- Eclipse
1001 128xDS1,
.
. 3-51,
321, - 641,
961,
/ . . H.
, DAC 155oM. 63E1
100xDS1 TDM- STM1/OC3,
SDH/SONET.
DAC 155oM SFP ()
15
40 .
1+1
Super-PDH Eclipse
1+1.
1+1
, . ,
(SD) /
1+19.
9
, ,
. , 1+1
, Portal
.
II-3-105
3. Eclipse
,
1+1.
Eclipse ( / )
1+1.
1+1
.
RAC 40,
,
/ ,
V H .
, 1+1
, (V H) .
RAC 40, 1+1,
. 3-129.
:
1+1,
.
,
10 BER 10-6. .
. 3-125.
1+1
(Rx) / (Tx). .
. 3-118.
1+1 "
" RAC.
,
, , .
. . 3-126.
1+1
1+0. .
. 3-126.
Event Browser
() .
. 3-52 , ,
.
10
1+1,
BER 10-6 .
II-3-106
Eclipse
. 3-53 ,
, - 1+0.
. 3-52. :
SD+SD
RAC
RAC
RAC
RAC
. 3-53. : SD +
1+0
RAC
RAC
RAC
, ,
, ,
(Tx) (Rx)
,
" ".
11 ,
,
5 .
, ()
(), ,
(Tx).
11
,
.
II-3-107
3. Eclipse
(Tx),
(Tx)
( RAC ).
,
"-",
( ,
1+0).
NMS 1+1 (
, 1+0).
1+1.
1+1
1+1.
XPIC
RAC 40
(CCDP),
Super-PDH
.
RAC 40
.
PDH RAC 40: 64x, 75xE1 70x,
84x, 100xDS1. (
),
,
64xE1 70x, 84x DS1.
INU.
RAC 40 , RAC 40 .
RAC 40 CCDP
. 3-129.
Ethernet-
Eclipse
Ethernet- :
, NxE1/DS1,
Ethernet-,
super-PDH. . . 3-109.
II-3-108
Eclipse
Ethernet,
Rapid Spanning Tree Protocol (RSTP),
. . Ethernet- . 3-110
,
Eternet .
(spanning tree) .
:
Eclipse DAC ES Fast Ethernet.
Ethernet-. Ethernet-,
RSTP-.
Eclipse DAC GE Gig-Ethernet.
Ethernet-, DAC GE
RSTP; RWPRTM (Resilient Wireless Packet Ring).
RSTP- .
Connect ES Eclipse Fast Ethernet.
Ethernet-,
RSTP-.
. 3-113.
Ethernet
( ) Ethernet-
Ethernet . E1
( DS1), Ethernet- DAC ES
, " ",
. ,
Ethernet-;
Ethernet,
(spanning tree). . . 3-54 . 3-110.
II-3-109
3. Eclipse
. 3-54. Ethernet-
DAC ES
. 2
6xE1 .
25 30
Ethernet
Ethernet
. 1
DAC ES
. 2
DAC ES
. 1
6xE1 .
19 24
6xE1
1
NxE1
. 2
. 1
DAC ES
DAC ES
. 1
. 2
6xE1 .
7 12
6xE1 .
13 18
D
. 1
. 2
DAC ES
, DAC ES
,
NxE1 ( NxDS1).
, ,
DAC ES 61.
, 1 DAC ES 2
, 61,
Ethernet -,
301.
Ethernet-
Ethernet
(rapid spanning-tree),
RSTP12 .
,
Ethernet-,
RSTP, "",
,
.
- ,
12
(Layer 2 )
(rapid spanning-tree protocol).
II-3-110
Eclipse
RSTP
.
RSTP IEEE 802.1D-2004
(STP).
DAC ES Connect ES RSTP.
DAC GE RSTP- RWPRTM,
, RSTP.
RSTP,
, ,
, RWPR
(FLD)
,
RWPR-, .
50 .
, Ethernet-
"-" . .
-. . 3-104.
" " RSTP
1 5 . ,
(STP) 50 .
RWPR ,
50 , 100
.
Ethernet
Eclipse Fast Ethernet Gigibit
Ethernet:
Eclipse c DAC ES Ethernet 100 /c.
DAC ES
, RAC, ,
RSTP.
E1/DS1- ,
- ()
.
Eclipse DAC GE Gig-Ethernet 150
/c. DAC GE
, RAC, -
. RSTP- .
II-3-111
3. Eclipse
300 /c
. 300 /c
300 /c
(2xSTM1/OC3), , ,
150 /c (1xSTM1/OC3).
600 /c
,
300 /c,
150 /c.
. 3-55 Ethernet- Eclipse/DAC ES
"-".
, E1,
Ethernet- (1-16),
, .
. 3-55. Ethernet-
RSTP
DAC ES
16xE1
-
1 16
. 2
LAN
Ethernet
. 1
16xE1
-
1 16
. 2
RSTP
. 1
DAC ES
. 1
RSTP
16xE1
- 1 16
NxE1
NxE1 -
. 2
. 1
DAC ES
DAC ES
RSTP
. 1
E
LAN
. 2
LAN
DAC ES
. 2
LAN
16xE1
-
1 16
RSTP
LAN
16xE1
- 1 16
16xE1
- 1 16
D
DAC ES
. 2
RSTP
. 1
LAN
Ethernet 16xE1,
-,
.
II-3-112
Eclipse
:
, E1
.
Ethernet- RSTP
Ethernet-.
RSTP :
DAC ES ,
( )
(C1 2).
DAC ES . C1
2, DAC ES
.
, DAC ES DAC GE,
Harris Stratex Networks, DAC ES
DAC GE.
, ,
. IP-
(VoIP)
-; , .
( ).
, 200 ,
.
; Intranet 5
, , ,
,
.
Ethernet ,
(, 64 )
;
, . ,
FEC/,
,
. ,
, RAC 30
DAC ES. . . 3-35 . 3-102
.
, Eclipse,
, , VoIP
II-3-113
3. Eclipse
, IP-,
. ,
.
II-3-114
Eclipse
/DAC
DAC E3/DS3 STM1/OC3
.
DAC:
DAC 3xE3/DS3
DAC 3xE3/DS3M
DAC 1x155o
DAC 2x155o
DAC 155oM
DAC 2x155e
: " "
" ".
DAC
Y-.
(Rx) ( ) DAC
, DAC (Rx)
TDM-.
(Tx) (Tx) DAC
,
(Tx) .
" "
DAC
.
(Rx) ( ) DAC
, DAC (Rx)
TDM-.
DAC
,
" "
.
" " , INU/
INUe Eclipse ,
DAC.
DAC .
- DAC (Tx) (Rx).
II-3-115
3. Eclipse
DAC 155oM,
(Rx) (Tx), , ,
DAC (Tx), -
(Rx).
, (Tx) / (Rx)
-. . DAC
. 3-127.
II-3-116
Eclipse
. :
. 3-117
. 3-118
. 3-123
. 3-124
DAC . 3-127
,
13 .
.
.
. ,
.
,
:
( )
,
( ).
,
.
, (Tx), -
(Rx).
5
320 (5 26 ).
.
13
( ) (Rx) .
II-3-117
3. Eclipse
(Tx) (Rx) .
RAC RAC
10v1. :
: RAC . 3-118
: RAC RAC 10v1
. 3-120
: RAC 10v1 . 3-122
. 3-122
RAC 10v1 001; RAC 10v2 - 002.
: RAC
;
200 .
,
(Tx) RAC .
(Tx)
RAC. ,
(Tx) RAC.
/
,
(Tx) RAC, (Rx)
RAC.
(Tx) " "
.
, (Tx)
. (Tx)
.
, ,
RAC
,
. ,
, ODU RAC, .
II-3-118
Eclipse
,
. RAC, , (
(Tx) )
.
,
/ :
RAC RAC c (Tx) .
(Tx)
, (Tx)
RAC, RAC;
RAC
/. (Tx) RAC
(Tx) RAC.
,
(Tx) , RAC/
ODU, .
,
.
(Tx) ,
200 .
,
:
:
RAC (RAC plug-in is missing)
RAC (RAC software
load failure)
,
:
(Tx synthesizer not locked)
(Tx transceiver
failure)
(Tx power failure)
ODU (Tx ODU IF
synthesizer not locked)
RAC (Tx RAC IF
synthesizer not locked)
II-3-119
3. Eclipse
RAC - ,
.
(Tx)
, .
II-3-120
Eclipse
(Rx) RAC.
RAC, RA /
, RAC, . .
. G-13, G.
RAC/ODU:
RAC/ODU ( ),
, ,
, RAC,
, TDM-.
RAC/ODU ( ),
, ,
,
(Rx) RAC ( ODU
(Rx) RAC).
RAC/ODU ( ),
,
( (Rx) RAC TDM-)
, () RAC/ODU
, RAC.
, RAC ,
RAC, Portal
Provision, .
RAC (Rx)
, RAC (Rx) , RAC
(Rx) .
, , ODU
RAC, .
(Rx) TDM-. , f
.
( ), RAC.
,
( ,
CompactFlash NCC), ,
.
II-3-121
3. Eclipse
RAC 10v1
RAC RAC
:
(Plug-in missing or incorrect)
RAC EEPROM (RAC software load
failure or EEPROM failure)
(Tx path failure):
(Rx synthesizer not locked)
(Rx IF
synthesizer not locked)
(Demodulator not locked)
ODU (ODU Tx cable IF
synthesizer not locked)
, RAC 10V1
.
,
, RAC,
Portal
.
(,
II-3-122
Eclipse
) :
RAC
200
20
20 ,
,
, .
- , ,
(Rx) ( );
( ).
.:
. 3-124.
, -
RAC
:
II-3-123
3. Eclipse
RAC
RAC:
RAC (RAC
software load failure)
EEPROM
(Tx path failure):
(Rx synthesizer not locked)
(Rx IF
synthesizer not locked)
(Demodulator not locked)
ODU (ODU Tx cable IF
synthesizer not locked)
,
, ,
,
.
- , :
200 .
-.
, -
(Tx);
.
(RAC/ODU) (DAC 155oM).
:
. 3-125
(DAC 155oM)
. 3-125
II-3-124
Eclipse
. 3-126
. 3-126
/
;
.
, :
(Tx path failure):
(Tx synthesizer not locked)
(Tx transceiver
failure)
(Tx power failure)
ODU (Tx ODU IF
synthesizer not locked)
RAC (Tx ODU IF
synthesizer not locked)
(Modulator not locked)
(Rx path failure):
(Rx synthesizer not locked)
(Rx IF
synthesizer not locked)
(Demodulator not locked)
ODU (ODU Tx cable IF
synthesizer not locked)
10-6 BER ( /
)
RAC (RAC plug-in is missing)
RAC (RAC software
load failure)
(DAC 155oM)
, :
SDH/SONET (Loss of SDH/SONET frame)
DAC 155oM (DAC 155oM plug-in is missing)
II-3-125
3. Eclipse
II-3-126
Eclipse
System/Controls ,
. Error-free Timer,
Delay Ring Unwrap Timer. ( ).
DAC
(Tx) (Rx)
, DAC 155oM.
.
200
(Tx) (Rx) .
DAC,
E3/DS3 STM1/OC3, DAC 155oM.
DAC.
:
(Tx) . 3-127
(Rx) . 3-127
(Tx)
DAC:
/ :
(Plug-in missing or incorrect)
FPGA (FPGA software load failure)
C LIU (LIU failure)
(Rx)
DAC:
/ :
(Plug-in missing or incorrect)
FPGA (FPGA software load failure)
C LIU (LIU failure)
(Clock generator failure)
LOS (Tributary LOS)
II-3-127
3. Eclipse
NCC NPC
NPC TDM- (
) NCC. INU/INUe
NPC.
;
/ .
TDM-; 200 ,
.
.
NCC , NPC
. .
NCC,
TDM- NPC,
NCC .
NCC / NPC,
System/Controls.
II-3-128
Eclipse
(CCDP) -
(XPIC).
, ,
, -
. ,
(
), (
DP) .
RAC 40 ODU 300.
:
XPIC . 3-129
RAC 40 . 3-131
XPIC
CCDP XPI,
- ,
.
- (XPD) 30 ,
40 .
, XPD
XPD .
XPIC CCDP . 5-9, III, 5.
XPIC 20+ XPD,
, .
XPIC RAC 40 G.
II-3-129
3. Eclipse
.
56
28
ACAP
CCDP
RAC 40
.
. 3-57 RAC 40 INU.
RAC 40 (
), RAC,
RAC.
II-3-130
Eclipse
. 3-57. RAC 40
STM1
INU
RAC
RAC
40
RAC
40
NCC
/ XPIC
DAC
RAC 40
RAC 40 :
STM1/OC3
64/75xE1
70, 84 100DS1
,
,
RAC 30;
751, 100DS1 STM1/OC3.
:
. 3-132
, , ATPC . 3-133
II-3-131
3. Eclipse
. 3-133
RAC 40 RAC 40 . 3-41
INU/INUe
100E1, 128xDS1 2xSTM1/OC3, ,
STM1/OC3. . . 3-58 . 3-134.
INU/INUe STM1/OC3,
.
INUe STM1/OC3 ,
( /
).
INU/INUe
64/75xE1, 70/84/100xDS1 STM1/
OC3.
RAC 40
INU/INUe, . 3-59.
H.
II-3-132
Eclipse
, , ATPC
RAC 40 XPIC
, (Tx) /
.
RAC 40
27,5/28 (ETSI) 30 (ANSI),
:
64x, 75xE1
70x, 84x, 100xDS1
STM1/OC3
, RAC 40 / ODU
.
- INUe
RAC INU/INUe.
ODU.
RAC 40 /-PIC,
.
ATPC . (
,
,
ATPC).
:
: INU . 3-133
: INU . 3-134
. 3-135
. 3-139
: INU
. 3-58 INU 2x STM1/OC3.
INU/INUe XPIC
2xSTM1/OC3.
,
STM1/OC3 DAC 155oM. (
DAC 155oM DAC 2x155o DAC 2x155e).
II-3-133
3. Eclipse
INUe 2xSTM1/OC3
XPIC, ( 4
DU). STM1/OC3 ODU
.
. 3-58. STM1
ODU 300
.
STM1
STM1
STM1 (.)
STM1 (.)
ODU 300
- XP
INU
RAC 40
NCC
STM1
RAC 40
DAC 155
STM1
Fan
DAC 155
2xSTM1
2xSTM1
: INU
INU/INUe
, . 3-59
150xE1.
,
200xE1, 256xDS1 4xSTM1/OC3:
2x 75xE1
2x 100xDS1 ( INUe ,
DAC 16x).
2x 75xE1 2x 100xDS1
. 3-59.
2x 75xE1 2x 100xDS1.
(
), 2x 64xE1 2x
84xDS1. . H.
2xSTM1/OC3.
II-3-134
Eclipse
.
ODU 300
75xE1 (.)
64xE1
.
ODU 300
RAC 40
Fan
RAC 30
NCC
- XPIC
RAC 30
NCC
DAC 16x
Fan
RAC 40
INU
INU
75xE1
150xE1
64xE1
11xE1
11xE1
( V H )
1+1, ,
.
1+1, 15.
RAC.
RAC 40, ,
1+1, - RAC 40
Portal Protection.
ODU
,
. ODU /
, ,
.
:
15
1+1 , XPIC
1+0 RAC 40 1+1 XPIC RAC 40,
V, H, , XPIC.
1+1, ,
.
II-3-135
3. Eclipse
2+2 .
4+4 .
2+2 4+4 . . 3-139.
2+2
. 3-60 ,
751.
,
, (
) .
(V H)
1+1.
NPC INUe
NCC.
.
3,5 ,
,
7 .
RAC 40
2+2: 64x, 75xE1, 70x, 84x, 100xDS1 STM1/OC3.
/
16xE1. INUe
591, -
75xE1,
751.
II-3-136
Eclipse
. 3-60. 2+2
ODU 300
A
ODU 300
.
A
75xE1 (.)
75xE1 (.)
75xE1 (.)
75xE1 (.)
.
B
RAC 40
RAC 40
RAC 40
NCC
NCC
9
NPC
INUe
Fan
RAC 40
Fan
RAC 40
RAC 40
16xE1
XPIC
RAC 40
RAC 40
RAC 40
RAC 40
75xE1
.75xE1
CCDP
CCDP
75xE1
75xE1
NCC
3
DAC 16x
9
NPC
INUe
Fan
CCDP . 2+2
RAC 40
Fan
RAC 40
16xE1
16xE1 /
16xE1
II-3-137
3. Eclipse
4+4
. 3-62 4+4 'quattro', CCDP
( ) ACCP (
)
" "
.
4x 75xE1, 4x 100xDS1 4x STM1/OC3
28/30 .
CCDP ACCP
28/30 .
V H . . 3-61
/.
. 3-62 ACCP F1 F2 ( 1 2),
CCDP - .
. 3-61. / 4+4
CCDP ACCP
ODU . .
3,5 ,
,
14 .
II-3-138
Eclipse
. 3-62. 4+4
CCDP
ODU 300
ACCP
A .
F1
A .
.
F2
.
F1
D .
F2
D .
CCDP RAC 40 Eclipse
.
, RAC 40, :
STM1/OC3,
SDH. Eclipse -.
PDH Eclipse Super-PDH.
(
)
641 84DS1.
H. .
.
Portal .
V H
, (Tx) /
.
XPIC RAC 40
RAC 40.
1+1:
II-3-139
3. Eclipse
1+1,
.
1+1
, .
, (SD)
/ 1+1.
1+1.
1+1,
.
1+1 (
). 1+1
1+1 . 3-105.
ODU
,
. ODU /
, ,
.
:
2xSTM1 /.
64xE1 / 16xE1.
64xE1 ,
.
4+4 CCDP ACCP.
II-3-140
Eclipse
2xSTM1
. 3-63 STM1.
INU 1xSTM1; STM1
STM1 .
INU STM1
SDH,
.
Eclipse -.
. 3-63. 2xSTM1 /
ODU 300
STM1 (.)
STM1 (.)
West
ODU 300
1xSTM1
1xSTM1
.
ODU 300
STM1 (.)
STM1 (.)
East
ODU 300
- XPIC
RAC 40
NCC
DAC 2x155o
Fan
RAC 40
INU
STM1 West
STM1 East
RAC 40
NCC
DAC 2x155o
Fan
RAC 40
INU
2xSTM1
2xSTM
2xSTM1
STM1 West
STM1 East
II-3-141
3. Eclipse
641
. 3-64 .
Eclipse Super-PDH
.
641 84xDS1.
. 3-64. 64xE1 /
16xE1
ODU 300
ODU 300
64xE1 (.)
64xE1 (.)
West
64xE1 (.)
64xE1 (.)
ODU 300
ODU 300
East
- XPIC
RAC 40
Fan
RAC 40
NCC
RAC 40
NCC
DAC 16x
Fan
RAC 40
16xE1
II-3-142
INU
INU
128xE1
128xE1
16xE1
Eclipse
,
. 3-65
.
,
(SD).
SD
.
SD
, SD .
SD (
). SD
" ,
1+1" . 3-86.
641
84DS1.
NPC INUe
NCC.
II-3-143
3. Eclipse
. 3-65. 64xE1
,
.
ODU 300
A
ODU 300
64xE1 (.)
64xE1 (.)
64xE1 (.)
64xE1 (.
.
RAC 40
RAC 40
RAC 40
NCC
NCC
9
NPC
INUe
Fan
RAC 40
.
Fan
RAC 40
RAC 40
16xE1
XPIC
RAC 40
RAC 40
RAC 40
RAC 40
64xE1
64xE1
CCDP
CCDP
64xE1
7
NCC
3
DAC 16x
9
NPC
INUe
Fan
CCDP .
.2+2
.
.
RAC 40
Fan
RAC 40
16xE1
16xE1 /
64xE1
16xE1
II-3-144
Eclipse
4+4 CCDP
ACCP
. 3-66 4+4 'quattro'.
Eclipse Super PDH,
(SD).
CCDP ( ) ACCP
( )
28/30 .
. . 3-61 /
.
641
84DS1.
.
3,5 ,
,
7 .
. 3-66. 4+4 CCDP
ACCP
CCDP
ACCP
ODU 300
A .
.
.
D .
F1
F2
F1
.
F2
F1
F2
F1
.
F2
II-3-145
3. Eclipse
Portal,
INU/INUe/ODU.
:
Portal . 3-146
. 3-147
. 3-147
5.
Portal
INU INUe (NMS) Ethernet V.24
Portal.
Ethernet ( NMS 10/100Base-T) :
.
TCP/IP
LAN . IP- INU/
INUe. Ethernet,
, IBNU/INUe.
DHCP-, INU/INUe
IP- Portal.
IP- .
V.24, IP- INU/INUe
.
Portal IV, 2.
Portal () INU/INUe,
V.24.
IP-,
Ethernet. INU/INUe
V.24.
Ethernet,
V.24. Ethernet
.
II-3-146
Eclipse
Diagnostics Portal :
Event Browser INU/INUe .
Helpset ,
.
G.826 BER G.826 -
BER- PDH SDH.
,
, AIS, , (Tx).
,
.
:
:
Portal . 5-2.
Portal .
. 15-1 IV.
, Portal
Diagnostic, Portal Diagnostics . 2-40
V.
II-3-147
4.
:
ODU . 4-1
ODU . 4-3
ODU
ODU 300 ODU 100.
:
( 380)
( 1050)
4-1. ODU 300ep Eclipse
II-4-1
4.
ODU 6
ODU , N-- female
ODU, BNC female ( )
RSSI-, .
ODU
Eclipse ,
.
ODU ,
(ODU
,
ODU ).
ODU .
, ODU
,
.
ODU (Tx).
ODU
,
.
.
- 3,5/3,5 . 1,5/6,5 .
ODU ASTME
2000 ,
IEC, UL Bellcore .
ODU 300ep 5
ODU 300ep 5
ODU 6 +, :
7/16 DIN female.
. ODU
.
(Tx).
II-4-2
Eclipse
ODU
ODU INU IDU Eclipse:
ODU 300ep
ODU 300hp
ODU 300sp
ODU 100
ODU 300 ODU 300ep. .
ODU: ODU 300hp ODU 300sp.
ODU 300ep ODU 300hp
. RAC 30,
RAC 40, RAC 3X IDU 300, IDUsp ODU 300ep.
ODU 300sp
IDU 300sp, RAC
30 IDU 300, IDU 155o.
ODU 300sp ATPC.
ODU ,
.
ODU 300- ODU 100
. 4-1.
4-1. ODU
ODU 300ep
ODU 300hp
ODU 300sp
5 23
7 38
7 38
7 23
7 38
4, 8, 16xE1
4, 5, 8, 10, 16,
20xE1
4 75xE1, 1 8xE3
4 75xE1, 1 8xE3
4 401
4 100xDS1, 1
6xDS3
4 100xDS1, 1
6xDS3
4 32DS1
2xSTM1/OC3
2xSTM1/OC3
QPSK 16QAM
QPSK
QPSK
3,5 56
5 56
5 30
7 28
7 28
II-4-3
4.
ODU 300ep
ODU 300hp
ODU 300sp
Tx
( 11 )
30
20
20
230 15 . 360 18 .
1.
. III, 2. :
Eclipse (ETSI
ANSI).
II-4-4
5.
Portal ProVision.
Portal
Eclipse.
ProVision ProVision
Harris Stratex Networks.
Eclipse - ,
.
:
Portal . 5-1.
ProVision . 5-5
Portal
Portal web-,
Eclipse. ,
,
, , Portal
.
IV, 1.
Portal
Windows,
.
INU/INUe IDU: 10/100Base-T
Ethernet V.24/RS-232:
II-5-1
5.
Ethernet
NMS / .
Ethernet:
LAN IP- TCP/IP
Portal.
DHCP-, / Eclipse ,
Portal - .
V.24/RS-232 DHCP,
IP- /. IP-
, /,
Ethernet.
Portal . 5-2.
Portal IV, 2.
Portal
. 5-1 , . 5-2 .
Portal IV.
. 5-1. Portal
(Diagnostics)
, ,
.
Plug-in/module setup
( )
,
.
Protection settings
( )
Eclipse RAC/
ODU , ,
.
RAC 30 DAC 155oM
.
,
IDU/IDU ,
.
II-5-2
Eclipse
Circuit cross-connect
configuration
(
- )
Eclipse Circuits -
. ,
TDM- NxE1, DS1, E3, DS3 STM1/
OC3.
Eclipse Circuits IDU ES.
Network management IP
addressing and routing
(
IP-
)
,
,
.
DHCP- Ethernet Portal.
Alarm Actions (
)
/
Eclipse.
,
.
License upgrade
( )
,
.
Software management
(
. 5-2. Portal
System summary (
)
.
/
INU/INUe.
- INU/INUe.
,
.
II-5-3
5.
Status bar ( )
. ,
, ,
System Summary
.
Event Browser (
)
, , .
,
. ,
.
csv (Excel).
History ()
G.826
, . ,
15- ;
.
G.826, RSL,
.
Alarms (
)
Performance
()
(RAC)
G.826, RSL, BER, ,
, ODU ODU.
DAC ES DAC GE RMON.
System controls (
)
, , AIS, ,
(Tx) BER.
DAC ES DAC GE
Ethernet-.
Circuit Loopbacks
( )
TDM-.
Parts ()
,
.
II-5-4
Eclipse
Advanced Management
(
)
:
( - - ),
Helpdesk Data File ( )
Portal.
"" () Event
Browser History.
ProVision
ProVision - Eclipse,
' '. ProVision Windows
Solaris, .
LAN/WAN IP-
.
IP-.
ProVision , .
:
. 5-5
. 5-6
ProVision . 5-6
SNMP (Simple Network Management Protocol ). ,
, .
,
. ProVision
( ), ,
ProVision .
.
II-5-5
5.
,
.
,
,
.
Scoreboard (),
.
,
.
ProVision
Eclipse,
.
ProVision Portal Eclipse.
Portal ,
.
ProVision
. 5-3 ProVision.
ProVision " ProVision".
. 5-3. ProVision
,
. , ,
ProVision. ,
, ,
.
.
( NOC, Portal, NOC),
.
,
, .
II-5-6
Eclipse
ProVision V.
, ,
.
Eclipse,
XP 4 DART,
.
.
, IP-,
, , ,
.
.
(, ) , ,
, .
,
.
.
.
,
,
.
,
.
XML-. ProVision
V, .
, ,
ProVision V. ,
.
, .
II-5-7
5.
,
. ,
, , .
.
,
. ProVision
V ,
.
(
) .
.
, , .
Eclipse . ,
, ()
.
,
,
.
.
ProVision V
ProVision V.
- ,
Eclipse.
-,
. ,
.
.
,
.
ProVision V.
.
II-5-8
Eclipse
,
(, , ).
.
: (),
(), (),
(), () ().
SNMP
ProVision V
Harris Stratex Networks, .
Eclipse
Eclipse.
Eclipse
Eclipse.
,
, txt .
ProVision V
, ,
, .
,
, .
,
. ,
.
, .
"" . , ProVision
V . ,
,
- , . ""
"".
, . ProVision V
. ,
, /
,
.
II-5-9
5.
G.826
.
,
, .
, ,
.
ProVision V.
,
.
(NBI)
ProVision V
.
NBI
ProVision, ,
.
NBI
ASCII, ,
.
NBI
, Eclipse
XML : IP- Eclipse,
, ,
-, IP- ProVision V.
NBI
, : ,
, , IP- ,
SNMP, (
).
II-5-10
6.
Eclipse
Eclipse. :
Eclipse . 6-1
Eclipse . 6-6
. 6-9
. 6-12
. 6-16
Eclipse
Eclipse
, ,
/ ,
, . :
Super PDH
-
Ethernet
II-6-1
6. Eclipse
XPIC
/
Eclipse ;
Eclipse .
,
.
4 751, 4 100DS1.
E3, DS3, STM1/OC3, Fast Ethernet Gigabit Ethernet.
: ,
,
. ,
XPIC.
5 38 .
. INU ODU.
INU
INU 1U ODU
, /
.
INUe 2U ODU
/
.
ODU RAC .
ODU
ODU:
ODU 300ep 5 23
(Tx), 4xE1/DS1 2xSTM1/OC3
QPSK 256QAM.
ODU 300hp 7 38
(Tx), 4xE1/DS1 2xSTM1/OC3
QPSK 256QAM.
ODU 300sp 7 38
(Tx), 4xE1/DS1 40x1/32xDS1
QPSK 16QAM.
II-6-2
Eclipse
ODU 100 7 38
(Tx), 4 20x1 QPSK.
,
STM1/OC3 E1/DS, E3/DS3 E1/DS1,
DAC STM1/OC3 E3/DS3
E1 DS1.
STM1/OC3 E3/DS3 E1/DS1
.
,
RAC/ODU.
RAC 30, ETSI
4E1 75xE1, 1xE3 4xE3 STM1.
4xDS1 100xDS1, 1xDS3 3xDS3 OC3.
RAC 3, ETSI
4E3 8xE3, 1x 2x STM1.
3xDS3 6xDS3 1x 2xOC3.
RAC/,
10xE1
16DS1.
/
, QPSK, 16QAM, 32QAM, 64QAM,
128QAM 256QAM.
Super PDH
75E1
100DS1 (Super PDH) ,
SDH. PDH
,
.
-
-,
. -
,
II-6-3
6. Eclipse
,
.
Eclipse,
,
751 100DS1; .
,
.
DAC
; DAC 155oM
DAC 3xE3/DS3M .
( ) DAC ,
E3/DS3 STM1/OC3, DAC 155oM.
; -
,
.
:
,
.
,
.
,
.
Ethernet
Eclipse
Ethernet-, Fast Ethernet DAC ES, Gigabit
Ethernet - DAC GE.
DAC ES
II-6-4
Eclipse
DAC ES ,
VLAN ,
QoS .
Fast Ethernet ,
100 /c.
150 /c
( - ) 100 /c (100
/c ).
E1 DS1.
DAC GE
DAC GE ,
VLAN , QoS
, RWPRTM,
VLAN.
RWPR RSTP (
), RSTP
5 , RWPR 50
.
RWPR
2 ,
.
Eclipse / DAC GE
, Nx2 /c, Nx1.5
/c Nx150 /c.
Nx2 /c Nx1,5 /c,
100 /c 200 /,
.
Nx150 /c, 150
/c , 300 /c .
E1 DS1.
(layer 2),
/ 600 /c
.
L1 (layer 1),
-
150 /c .
II-6-5
6. Eclipse
XPIC
,
.
XPIC
.
64 /c,
19,2 /c ( 1,2 19,2 /c )
, / .
/ TTL-
4 Form C AUX.
Eclipse
Eclipse - ,
IDU ( ) ODU.
.
, Eclipse
.
PDH, SDH
Ethernet.
:
100 . 6-7
300 . 6-7
ODU . 6-8
. 6-8
/
. 6-8
II-6-6
Eclipse
100
QPSK 7 38
.
IDU 8x 4
81.
IDU 16x 4,
8 161.
IDU 20x 4x,
5x, 8x, 10x, 16x 20xE1.
IDU 8x IDU 16 1+0
(). IDU 20x
1+1 .
300
PDH- Ethernet- 5 38 .
IDUsp 4x - 41, QPSK, .
IDU 16x - 4x, 8x 16xE1, QPSK.
.
IDU 300 8x - 4x, 5x 8xE1/DS1, QPSK
16QAM. .
IDU 300 20x - 4x, 5x, 8x, 10x, 16x 20xE1/DS1,
QPSK 16QAM.
.
300 20xV2 - 5x 40xE1, 4x
32xDS1, QPSK 128QAM.
,
. 20xE1/DS1
; 40xE1
32xDS1 .
IDU 155o - 1xSTM1/OC3 LC-,
16 128QAM. ,
.
IDU ES - Ethernet 200 /c, 8xE1/DS1 ,
QPSK 128QAM. .
10/100base-T,
VLAN QoS.
II-6-7
6. Eclipse
,
QPSK 128 QAM,
.
Connect ES Eclipse IDU ES
ODU.
ODU
ODU , . . ODU
. 6-2.
Eclipse,
,
IDUsp.
,
, 8
16 20 .
,
Eclipse, RAC, DAC ODU,
.
/
, IDUsp,
, / :
64 /c 19,2 /c ( 1,2 19,2 /c).
/ TTL-
Form C.
IDUsp (4x 16)
64 /c. /
.
II-6-8
Eclipse
:
ATPC
FEC
(Tx)
ATPC
Eclipse
(ATPC)
0,1 . ATPC / Portal,
,
.
FEC
RAC IDU FEC - (
).
RAC 3X, RAC 40, IDU ES IDU 155o
/.
FEC - 8
250/255 ().
10-6 3 .
.
,
, FEC
.
, 2
4 .
,
() ,
, /
.
()
,
II-6-9
6. Eclipse
.
,
, , .
. Eclipse
, IDUsp.
(Tx)
Eclipse
:
.
ODU 300ep ODU ,
30,5 .
ODU 300hp ODU ,
28,5 .
ODU 300sp ODU ,
25 .
ODU 100 ODU ,
23 .
ODU 300ep 0,1
30 QPSK, 24/25 QAM,
+/-2 .
. 6-1
ODU 300ep ATPC.
ODU 300hp ODU 300sp,
20 QPSK, 16 128 QAM ODU 300hp.
+/-2
.
ODU 100 (ODU 100v2) QPSK,
0,1
25 , +/-2
.
II-6-10
Eclipse
6-1.
ODU 300ep
-10
30 - QPSK
25 - QAM
-20
-25
-30
ODU 300- ODU 100
(Tx).
,
.
(Tx)
ODU . ,
Portal / (Tx),
.
II-6-11
6. Eclipse
:
/
System Summary
/. ,
.
.
Events Browser 5000
, , .
,
.
.
: ,
.
.
History
,
15
, .
, G.826, RSL,
. Ethernet,
(Rx) (Tx), , , ,
.
II-6-12
Eclipse
Alarms
. ,
,
.
/
System/Controls :
Link ()
Ring ()
Data ()
AUX
Link ()
Link RAC ,
,
(Tx):
:
RAC ().
.
II-6-13
6. Eclipse
TDM- ().
(Tx) /
(Rx),
.
.
Ring ()
Ring RAC,
.
RAC; (Tx)
RAC, .
RAC; (Tx)
RAC, .
Online () /
RAC ; . Offline
()
.
.
Data ()
PDH, SDH DAC , Data
,
AIS PRBS G.821.
Ethernet DAC IDU ES,
,
.
DAC,
(Tx) (Rx) .
.
AIS.
().
BER-. PRBS G.821
,
BER 215-1.
PRBS, G.821.
, ,
,
.
, .
II-6-14
Eclipse
PRBS 215-1
BER-.
. , PRBS
.
Ethernet
,
,
.
AUX
AIS, AUX ,
DAC/ PDH.
TDM- .
Eclipse.
E1, E3, DS1, DS3
STM1/OC3. .
,
,
.
PRBS DAC,
, Eclipse.
,
, .
Eclipse . 2-14, V.
II-6-15
6. Eclipse
Eclipse
, Portal
(EMS) ProVision.
.
, :
:
(NBI)
Eclipse . ,
( ).
,
,
.
.
E1/E3, DS1/DS3 STM-1
.
,
.
,
.
II-6-16
Eclipse
, ,
. ,
PRBS- .
,
. ,
, ,
G.821.
,
.
,
.
Ethernet-
RMON Ethernet
,
Ethernet,
, ,
, /
.
: ,
.
.
RSL G.826
15
.
, ;
, ,
.
II-6-17
6. Eclipse
,
, .
,
, , ,
.
.
:
(NBI)
EMS Eclipse
(NBI),
(NML). :
NBI
NBI
NBI
NBI
NBI
NBI
NML,
.
, SNMP ASCII.
NBI NML :
EMS NML
II-6-18
Eclipse
NBI
NBI
NML.
NBI NML :
IP- ,
(RSL): ,
(BER): ,
G.826
15 , ,
. - ASCII.
NBI
NBI NML .
.
IP-
SNMP
( )
(/
15 , )
XML.
NBI
NBI ,
Eclipse Eclipse.
:
Eclipse, IP-
, , ,
II-6-19
6. Eclipse
,
-
XML.
Eclipse,
, NMS E1 (NMS over
1). NMS 1
.
II-6-20
III
Eclipse
1.
Eclipse,
.
:
. 1-1
. 1-2
. 1-3
Eclipse EMC, 89/336/EEC,
.
;
.
Eclipse .
,
.
.
, Eclipse,
.
1
III-1-1
1.
Eclipse.
Portal Eclipse,
. Portal Eclipse.
:
1.
:
2.
ODU
ODU
ODU ( )
INU / IDU
INU
NMS
3. Portal Eclipse
4.
Portal
()
RSSI ODU RSL Portal
III-1-2
Eclipse
,
.
. 1-1 ,
.
1-1.
Eclipse
,
.
19 (3/4) - ODU
.
66 /
,
N - Andrew.
III-1-3
1.
BNC
RSSI
ODU .
BNC-"" .
Harris Stratex Networks
.
"" "
Eclipse".
42 (#12)
-
16 2 (#6)
-
:
1. ,
.
2. ,
,
,
.
3. -
,
Harris Stratex Networks.
III-1-4
2.
:
ODU
ODU
.
ODU
.
, 1,8 .
ODU ,
ODU.
,
, ,
,
.
ODU
.
III-2-1
2.
( ODU
) .
Harris Stratex Networks .
ODU
ODU; ODU 300 ODU 100.
II, 4.
ODU 300 ODU 300ep ( ODU 300), ODU 300hp,
ODU 300sp.
ODU 300 ODU 100 ,
( ),
-1.
ODU 100V1 ,
V2. V2
4, 5, 8, 10, 16, 20xE1 7 38
V1 - 4, 8, 16xE1 7 23 . V1 V2
4,
8, 16xE1. V1 001 , V2 002.
ODU, ODU 300ep 5,
.
ODU 300 (300ep) 5 7/16" female DIN
.
ODU
.
ODU .
( ).
:
ODU, . 2-3
ODU, . 2-9
ODU . 2-13
1
ODU ;
.
III-2-2
Eclipse
ODU,
:
. 2-3
. 2-5
ODU . 2-8
ODU
19 (3/4) .
ODU, , . 2-1.
2-1. ODU, Andrew
III-2-3
2.
. 2-2 ODU,
Andrew.
2-2. ODU Andrew
. 2-3 ODU,
Radio Waves.
2-3. Radio Waves
III-2-4
Eclipse
. 2-4 ODU,
Precision.
2-4. ODU Precision
: . 2-5.
,
, ,
ODU.
, ODU
.
.
.
,
.
Radio Waves Andrew.
.
Andrew
Andrew:
1. ( )
III-2-5
2.
10 . ,
,
.
2. 90,
.
3. V H
. . . 2-5 . 2-6.
4. ,
.
2-5. ODU Andrew
Radio Waves
.
Radio Waves:
1. . . . 2-6.
2. . . . 2-6.
3. ,
.
4. .
III-2-6
Eclipse
. 2-6
()
().
2-6. Radio Waves
ODU
ODU
.
. 2-7.
2-7. ODU
ODU .
III-2-7
2.
: ODU
. 2-8.
ODU
ODU
.
:
ODU; .
. 2-25.
ODU; . ODU . 2-13
ODU ; .
ODU . 2-20
ODU
ODU .
ODU:
1. , ,
, ODU
, .
2. ,
. .
. 2-5.
3.
ODU .
ODU.
4. ODU.
5. ODU , (ODU
) , ODU
.
6. ODU ,
,
ODU ,
.
7. ODU ,
.
8. ,
III-2-8
Eclipse
.
9. , ,
19 .
10. ODU .
, ODU ,
.
ODU,
:
. 2-9
. 2-11
. 2-12
ODU ,
:
ODU 6 .
ODU 5
. 7/16 DIN female.
-
- .
ODU,
. ,
ODU.
ODU 5 .
XPIC ODU
.
112 . . 2-8
ODU, .
III-2-9
2.
2-8.
,
600 (2 ) 900 (3 ).
,
,
.
. ,
,
,
, . . 2-9
.
2-9.
C, .
III-2-10
Eclipse
-
ODU ,
, -
.
900 (3 ),
Eclipse,
Harris Stratex Networks.
:
. 2-11
. 2-12
. 2-1 , ODU
300 ODU 100,
. UDR/PDR ;
UBR/PDR .
ODU :
UDR. 6 8 (6/8
), ,
.
UBR. 4 ,
.
:
PDR. 6 8
.
PBR. 4 .
.
III-2-11
2.
2-1.
ODU
UDR70
PDR70
WR137
8 x M5
M5x0.8
6H
10
+
- 2
7/8
UDR84
PDR84
WR112
8 x M4
M4x0.7
6H
+
- 2
10/11
UDR10
0
PDR100
WR90
8 x M4
M4x0.7
6H
+
- 2
13
UBR12
0
PBR120
WR75
4 x M4
M4x0.7
6H
+
- 2
15
UBR14
0
PBR140
WR62
4 x M4
M4x0.7
6H
+
- 2
18/23/26
UBR22
0
PBR220
WR42
4 x M3
M3x0.5
6H
+
- 2
28/32/38
UBR32
0
PBR320
WR28
4 x M3
M3x0.5
6H
+
- 2
, ODU
.
:
ODU; .
. 2-25.
ODU; . ODU . 2-13
ODU ; .
ODU . 2-20
112 .
- , .
.
ODU ( )
ODU,
. ODU 5 (
),
.
ODU ODU .
III-2-12
Eclipse
1. ,
, ,
.
2. ODU,
.
3. ODU,
.
4. ODU ,
, ODU
, .
5. 19 .
6. ()
, 1 .
7. ,
, .
8.
, , .
, .
ODU
ODU
.
Harris Stratex Networks. .
. 2-25.
ODU,
ODU
,
. .
. 2-34.
ODU.
:
. 2-39.
ODU
ODU ( )
III-2-13
2.
:
1. ODU 2
. ,
.
2.
ODU. ,
.
3. , .
ODU.
ODU
. .
4. ,
,
.
5. ,
.
ODU.
6. 25 , ,
.
7.
.
ODU.
:
. 2-15
. 2-15
. 2-18
III-2-14
Eclipse
()
.
3,5
(3,5 / 3,5 ), , ,
7
.
1,5/6,5 .
, - 13
.
, -
.
() "
" Harris Stratex Networks.
, IV, 7.
,
.
, .
,
, ODU. Harris Stratex
Networks
, .
,
.
ODU , , ,
ODU .
,
III-2-15
2.
0 90 ,
.
.
,
ODU.
:
2.
1. (
. 2-5)
1. ,
. ,
.
.
2. ,
ODU/, ,
, .
3.
ODU .
ODU .
4.
.
5. , (
) , ODU
.
6. ,
,
,
.
7. ,
.
8. ,
.
9. , ,
19 .
10.
.
III-2-16
Eclipse
III-2-17
2.
2-11. ODU
2-12. ODU:
ODU
III-2-18
Eclipse
,
,
.
. 1+0
,
ODU / ODU.
Harris Stratex Networks.
III-2-19
2.
ODU
ODU Eclipse
.
, Harris Stratex Networks Eclipse
.
:
. 2-20
. 2-21
. 2-22
- . 2-24
N - . 2-25
:
Belden 9913
Hansen RG-8/U
Cinta CNT-400
Cinta CNT-300
Andrew BR-400C
.
ODU 50, 80, 15 300
(165, 260, 490, 980 ).
"" " Eclipse".
ODU, D.
III-2-20
Eclipse
2-2.
,
/.
, RG-8/
U-, Harris Stratex Networks,
: 840-600203-001.
,
.
,
,
.
,
.
N -
N - (male female)
.
. .
. 2-40.
(
).
,
.
,
,
.
, ,
,
.
III-2-21
2.
,
.
(
ODU) .
,
,
. 2-22.
,
,
.
ODU
/ ODU :
, ODU .
, .
25 ,
50 (165 )
.
, ,
. . . 2-16 . 2-28.
. . 2-22
.
, , ,
, ,
,
. "
" Harris Stratex Networks.
,
.
III-2-22
Eclipse
2-13.
1
2
3
10
9
12
11
13
14
III-2-23
2.
ODU
ODU
58
ODU
1 . ODU
.
50 ,
23 .
10
11
12
13
INU/INUe/IDU
14
-
- INU/INUe IDU
, .
INU/INUe ( Eclipse) RAC
3- -, SMA mal
RAC N - .
3- ,
- N - .
IDU ( Eclipse) - 3
IDU.
N - male IDU N - female
.
ODU.
- (1 x N - male 1 x N - female)
.
III-2-24
Eclipse
N -
ODU, D.
N -, ,
. .
. 2-40.
, . ,
, ,
.
Harris
Stratex .
ODU, ,
Harris Stratex Networks ,
Harris Stratex.
" "
.
.
15 , ,
.
:
BGXZ-60NFNM-AS
MHT250-N48
.
,
ODU.
:
III-2-25
2.
. 2-26
. 2-27
ODU . 2-29
, , ,
ODU.
.
2-14.
III-2-26
Eclipse
ODU,
.
, ,
Harris Stratex Networks .
.
" "
Harris Stratex Networks.
. 2-3 :
.
2-3.
,
.
. . . 2-15 . 2-28.
.
. . . 2-16 . 2-28.
.
III-2-27
2.
2-15. ,
7
1
8
2
5
9
10
2-16. ,
7
1
3
8
2
2
5
9
10
III-2-28
ODU
10
Eclipse
, :
1. , .
.
2. ODU ,
. N - male
ODU,
N - female .
3. (RAC
Eclipse) -. .
- . 2-24.
4.
.
5. ,
.
Harger
,
, .
6.
//
.
7. ,
. .
. 2-40.
//
.
ODU
ODU.
ODU
( )
, ODU ( ) .
,
.
, ,
ODU
.
III-2-29
2.
ODU.
2007 ''
; ,
,
ODU. . . 2-18 . 2-19.
, .
N- , ODU.
.
2007 ''
.
,
. .
.
. 2-17 . 2-31.
, ODU
-. .
.
.
III-2-30
Eclipse
2-17. ODU:
3
4
1
2
ODU
ODU
58
RSSI
III-2-31
2.
2-18. :
2-19. :
:
, RSSI
III-2-32
Eclipse
;
BNC.
III-2-33
2.
,
'' .
, .
N-
.
:
, 1 13 .
1. N - (
ODU) .
2. , , - .
3. -
,
.
. . 2-41.
III-2-34
Eclipse
4. , ,
.
5.
ODU , .
6. N -.
7. ODU
.
III-2-35
2.
8. .
9.
,
.
10.
ODU.
( ).
11.
,
.
12. ,
III-2-36
Eclipse
13.
ODU .
14. ODU
. ,
( )
. ,
, ODU
.
ODU
.
ODU ,
.
15. ,
, 25
ODU, female. .
. 2-41.
16.
III-2-37
2.
.
17. ODU
200 (8 ) ,
.
18. /
, .
19.
Harger.
, ,
.
20. .
. 2-20 .
2-20. ODU
III-2-38
Eclipse
:
1. ODU.
2. ODU
N -. ,
( )
.
ODU
,
ODU
.
ODU ,
.
3. . . ,
. 2-41.
4.
.
5.
Harger.
, ,
.
6.
ODU.
7. . . ODU . 2-13.
8.
ODU.
III-2-39
2.
ODU .
.
:
ODU
. :
.
.
-
-.
,
,
, ,
.
,
, .
,
, 1.
,
3.
1. , , ,
. , ,
- .
2. .
25%. ,
.
ODU , ,
,
.
III-2-40
Eclipse
3. , 75%. ,
25 (1) (25
).
.
4. ,
,
, .
, , .
5. .
, .
,
.
,
. ,
, , N -
,
ODU.
,
1. , , ,
. , ,
- .
2. ( ),
75%.
3. , 25 (1) ,
,
. ,
( ).
4. ,
.
5. ,
.
III-2-41
2.
III-2-42
3. INU INUe
INU/INUe
INU/INUe -
ODU Eclipse.
INU/INUe (IDC/IDCe) .
IDC/IDCe NCC FAN,
(IDC), (IDCe)
RAC, DAC, AUX NPC.
on page 3-9.
:
IDC V1 IDC V2
III-3-1
3. INU INUe
IDC V1 IDC V2
IDC,
,
NPC:
IDC V1 NPC
. NCC. IDC V1
NPC.
IDC V2 IDCe NPC
, .
IDC V1 EXC-001. IDC V2
EXC-002.
IDC V1 .
V2. IDCe - V2.
. 3-1 INU, DAC x16,
RAC 30 .
, II,
3.
3-1. INU
On-Line
RAC 30
Status
DAC 16x
To
ODU
FAN
Status
Trib 1-8
Trib 9-16
Fault
-48VDC
RAC 30
On-Line
To
ODU
Status
III-3-2
Eclipse
ID.
.
,
.
RAC 30
RAC 30, 1
NCC
( )
, 2
RAC 30
RAC 30, 4
DAC 16x
16xE1/DS1 DAC, 3
FAN
( )
IDC.
.
5 (16 ), - 4 2 (AWG 12).
( ) -48
. ( ); - /.
3-2.
,
. .
III-3-3
3. INU INUe
NCC NPC 25 A ,
.
NCC /
, - 12,5 .
INU/INUe
3-1. INU
INU/INUe
, ,
, .
INU/INUe
. 50 (2 )
, .
.
INU/INUe (Tmra)
+45 (113 ).
(Tmra) +45
INU, , ,
.
, INU/INUe
.
III-3-4
Eclipse
INU
.
-48 .
; -
INU.
INU/INUe.
INU/INUe ,
,
(, ),
, .
UL IEC SELV -48 (60 .
).
, Eclipse
,
.
Eclipse
, :
12.5 A INU
25 A INUe
INU ,
,
. .
INU .
. ,
.
INU
INU, :
1.
,
III-3-5
3. INU INUe
.
2. INU/INUe
No.12 Phillps
IDC.
3. INU/INUe
/, 4 2 (AWG 12)
-
( ).
4. / ,
16 2 (AWG 6)
.
.
,
,
.
5. ,
( )
. ,
. . on
page 3-9 on page 3-9.
6. - RAC
.
7. /
.
- , . .
- on page 2-24 2.
8. DAC.
E.
DAC 16x, Mini
RJ-21 .
- . ,
Harris Stratex Networks, ,
.
Mini RJ-21.
9 14 ,
. ,
.
III-3-6
Eclipse
9.
, .
( ) 12 A INU 25 A
INUe.
10. ( ) -48 .
( ); - /.
.
11. .
-48 . , +/-2 . ( - -40.5 - 60
Vdc).
SELV (
), ,
SELV (48 , 60
) .
INU/INUe
. .
, , , NMS-
Eclipse
.
, .
12. . ,
ODU ODU ,
Eclipse .
() ODU
,
. ( ODU,
-, ,
).
,
.
13. NCC.
,
. .
Eclipse .
:
III-3-7
3. INU INUe
Eclipse. .
.
Eclipse. . .
IV, 4.
III, 5.
III-3-8
Eclipse
IDC . IDCe
,
4 . . . 3-3
. IDC/IDCe
INU/INUe.
3-3. INU INUe
INU
2
NCC
Fan
INUe
3
NCC
Fan
Fan
10
- . . 3-2
. 3-11 .
/ 2007 IDCe ( INUe) IDCe.
IDCe FAN 2U,
FAN 1U.
IDCe FAN
2U.
. 3-2 .
, INU/INUe.
.
III-3-9
3. INU INUe
,
III, 3.
E.
2, 7.
.
III-3-10
Eclipse
3-2.
, .
FAN.
DAC 16x
DAC 16xE1/DS1
.
AUX
INU/INUe AUX.
NPC
, INU/INUe,
.
.
.
.
,
.
, Harris Stratex Networks
.
III-3-11
3. INU INUe
.
.
NCC (
NPC).
,
,
,
.
INU/INUe
60 ,
Portal.
. ,
,
.
NCC
NCC
NCC: V1 V2.
NCC V2 4 Ethernet NMS,
,
2W2C D-series (D-).
NCC V1 3 Ethernet NMS,
.
: NCC V2.
:
NCC V1 NCC V2 .
NCC V1 INU.
INUe. NCC V2 : INU INUe.
NCC V1
NPC.
NPC ( ). NCC
V2 ,
.
III-3-12
Eclipse
RAC
/
ODU / RAC
ODU RAC INU
RAC .
: ODU ODU.
RAC,
,
.
,
,
, INU/INUe.
.
RAC
INU
RAC INU
RAC ,
ODU. RAC
ODU
.
RAC
INUe
INUe RA
:
/
/
/
DAC
DAC
DAC
,
, - ,
.
: E1, DS1, E3, DS3 STM1/OC3.
DA
E1
DS1.
III-3-13
3. INU INUe
,
INU DAC.
Mini RJ-21
DAC 16x
Mini RJ-21
.
- .
, Harris Stratex Networks,
, .
,
- .
( DAC)
()
DAC E3/DS3 STM1
.
( DAC)
()
DAC STM1/OC3
.
Eclipse
,
Eclipse, INU/INUe,
, :
100x E1
128xDS1
8xE3
6xDS3
2xSTM1/OC3
,
, .
INU/INUe ,
, ,
INU/INUe.
III-3-14
4. IDU
IDU - Eclipse.
Eclipse: 3.
:
IDU . 4-1
. 4-3
IDU . 4-4
IDU . 4-6
D.
IDU
IDU , ODU
Eclipse. IDU 100 ODU 100; DU
300 ODU 300: ODU 300ep, ODU 300hp
ODU 300sp.
IDU:
100, :
III-4-1
4. IDU
III-4-2
Eclipse
IDU, IDUsp, ,
IDU, 2- 2W2C,
, .
5 (16 ), - 4 2 (AWG 12).
IDUsp 2- Phoenix
. 5 (16 ),
- 4 2 (AWG 12).
( ) -48
. ( ); - /.
4-1. 2W2C
2W2C
, .
.
III-4-3
4. IDU
4-2. Phoenix
-48 .
6 (1/4")
/
IDU
4-1. IDU
IDU
, , , ,
.
III-4-4
Eclipse
, IDU
.
IDU
.
-48 .
; -
IDU.
IDU.
,
.
- .
IDU ,
, (,
), ,
.
UL IEC SELV -48 (60 .
).
, Eclipse
,
.
IDU Eclipse
, 5 A.
IDU ,
,
. . IDU
.
.
, .
III-4-5
4. IDU
IDU
IDU, :
1. IDU.
,
.
2. IDU
No.12 Phillps
IDU.
3. IDU /
, 4 2 (AWG 12)
-
( ).
4. / ,
16 2 (AWG 6)
.
.
,
,
.
5. -
IDU ,
. . -
. 2-24, 2.
6. /
. .
7. .
, Ethernet
E.
8 13 ,
. ,
(
, ,
'0' ).
8.
, .
( ) 5 A.
9. ( ) -48 .
( ); - /.
III-4-6
Eclipse
.
10. .
-48 . , +/-2 . ( - -40.5 - 60
Vdc).
SELV (
), ,
SELV (48 , 60
) .
IDU
. .
, , , NMS-
Eclipse
.
, .
11. . ,
ODU ODU ,
Eclipse - .
2W2C
, .
.
ODU
,
. ( ODU,
-, ,
).
,
.
Eclipse -.
:
III-4-7
5.
:
. 5-1
. 5-2
. 5-4
. 5-13
, :
ODU .
.
,
.
,
. ,
RAC ,
.
III-5-1
5.
, RSL Portal
RSSI BNC ODU. :
RSL
RSSI ODU
RSL
RSL
Portal INU IDU,
,
Portal .
RSL:
1. RSL Portal.
2. RSL.
3. .
4. RSL RSL
.
:
ODU 300 (ODU 300hp, ODU 300ep, ODU 300sp):
2 -40 -70 , 0
+35oC.
4 -25 -85 , -33
+55oC.
ODU 100
3 -40 -70 , 0
+35oC.
4 -25 -85 , -33
+55oC.
III-5-2
Eclipse
RSSI ODU
RSSI BNC ODU
, , .
ODU BNC .
RSSI:
1. BNC.
.
, FSD 2,5 . .
2.
.
3. .
4. .
RSSI RSL. RSSI 0,25 . RSL
-10 , RSSI 0,25 .
RSL 10 ,
:
BNC (
..)
0.25
0.5
0.75
1.0
1.25
1.5
1.75
2.0
2.25
2.5
RSL ()
-10
-20
-30
-40
-50
-60
-70
-80
-90
-100
5. RSL
. . RSL.
6. BNC.
BNC RSSI,
ODU.
RSL
RSSI 56 ,
,
1. ,
( )
III-5-3
5.
.
, , ATPC
.
ATPC RSL. ,
RSL, ATPC.
(Tx)
RSSI/RSL .
XPIC ,
RSL , ATPC.
RSSI/RSL
RSSI/RSL
,
(Tx),
RSSI/RSL.
, -
, ODU 300 4
( 2 , 2 , 0
35C), ,
3 .
, RSSI/RSL
4 ,
, .
RSSI/RSL ,
, .
20 RSSI/
RSL ,
, .
,
1
RSSI /
. Eclipse ETSI
FCC .
III-5-4
Eclipse
.
( ) (
) .
.
,
, . ,
.
,
. ,
,
.
:
XPIC CCDP
, ,
. . 5-13
. 5-14
, ATPC .
:
1. ( )
.
2. , ,
.
3. ( )
.
4. , ,
.
.
5. RSL / RSSI .
III-5-5
5.
RAC/
ODU, . ODU
.
RAC/ODU, . ODU .
, - .
, ODU
, .
1+0.
,
, ,
(Tx),
.
.
RAC, RAC 10v1, (Rx)
(Rx)
. (
), , ,
(Rx).
RAC 10v1
RAC, (Rx)
.
(Rx), RAC 10v1
(Rx).
IDU IDU, ,
(Tx) (Rx). IDU 155o IDU 300 20xV2
(Rx),
(Rx).
IDU
(Rx), ,
(Rx), IDU ()
(Rx) (Tx).
1. ;
.
III-5-6
Eclipse
2. , RAC/IDU
,
RAC/IDU,
(Tx) ,
.
Portal RAC ,
RAC (Tx), -
(Rx). , ,
RAC
(), , ,
RAC (Tx).
RAC, RAC 10v1, (Rx)
Auto/Lock Off ().
RAC 10v1 RAC,
(Tx)
(Rx).
IDU IDU,
, (Tx)
(Rx). IDU,
().
, RAC/ODU
(Tx)/(Rx)
.
3. Portal > Diagnostics > System/Controls,
/.
4. . 5-5
, ,
, RSSI/RSL RAC/IDU,
(
RAC/IDU)2.
5. Protected Link
Auto/Lock Off.
,
, ,
,
(Tx).
1. Portal > Diagnostics > System/Controls , RAC/
IDU3 (Tx), (Rx).
2
RAC/IDU , RSSI/RSL.
III-5-7
5.
RAC , RAC
(Tx), - (Rx).
IDU 155o IDU 300 20xV2 ,
IDU (Tx), (Rx).
2. Protected Link,
RAC/IDU (Tx)
. (Rx)
Auto/Lock Off4.
3. . 5-5
(Rx).
RSL:
RAC Diagnostics > Performance, Links
Plug-in, RAC
RSL, Link Plug-in RAC. RAC
.
IDU () Diagnostics >Performance
IDU.
4. Protected Link
Auto/Lock Off.
.
1. () RA RSSI/RSL,
. 5-5
. ,
,
System/Controls > Protected Link,
RAC (Tx) (Rx)5.
. 5-5.
3
4
III-5-8
Eclipse
XPIC CCDP
XPIC ( -
) CCDP ( )
,
XPIC.
- 30 ,
- ,
.
XPIC
/ 20
, , , ,
.
-
30 ,
40 .
Diagnostics > Performance.
-
RAC 40 ( ).
XPIC RAC
40, .
, ,
.
PIC ( ODU ),
.
XPIC
, (Tx)
/, ATPC .
, :
, , ,
.
III-5-9
5.
,
, (
).
- (XPD).
- .
, ,
,
- .
.
:
1.
,
, ,
/
:
, ,
.
. ,
, ,
,
. . . 5-1.
5-1.
III-5-10
Eclipse
,
( ) (
).
,
- ,
.
2.
, (
) ,
, .
. . 5-5. ,
3.
3. RAC 40
.
RAC 40,
, ,
.
Performance , :
(Tx) 1
() RAC 40. ,
(Tx).
RSL 2 RAC 40.
RSL . 5-2
.
.
,
() RSL ,
.
4. -
(XPD) RAC 40,
Performance,
.
XPD 25 ,
.
25 , .
, 1 2,
25 Diagnostics > Performance
RAC 40, XPIC.
,
.
III-5-11
5.
5.
.
.
/ .
, ,
.
.
, ,
,
- , , ,
- .
,
.
6. ,
, Performance Portal
RAC 40,
.
,
Cross Pole Discrimination, RAC 406.
7.
XPD RAC 40,
.
,
.
, ,
,
2. ,
.
,
, .
1,5 .
8. XPD RAC 40 ,
1 2
.
9. , , XPD .
10. .
6
Portal. INU
( IP-) INU ( IDU).
III-5-12
Eclipse
,
. :
, ,
.
,
, . ,
1,2 23
0,9 (0,4 -3 ).
. ,
1
114 .
, (
),
.
,
,
.
.
, ,
20-25 .
,
2 .
.
. 5-2 . 5-14
,
.
III-5-13
5.
5-2.
1
2
3
4
5
6
, 3-10 .
, 30
.
1- , 20-25
.
, 30
.
. ,
, ( ),
.
. 5-3
,
.
III-5-14
Eclipse
5-3.
6 7
6
B
1
5
2
B
3
C 3
C
5
4
B
1
A
B 2
2
3
A 1
.
2, - 1 3.
, .
, 4 5.
- ,
,
.
,
.
, ,
.
(6 7) ,
.
, 6 7,
.
, ,
,
,
, , . 5-4,
.
III-5-15
5.
DD, ,
1.
5-4.
E
1
D
D
D
1
3
E
III-5-16
IV
Portal
1. Portal
Portal.
:
Portal . 1-1
Portal . 1-3
Portal . 1-8
Portal Auto Version . 1-9
Portal
Portal , Windows. .
1-2 . 1-2 .
/ .
,
.
, ,
, Send (), ,
,
.
.
Ethernet-, IP-
Ethernet- /. V.24-, IP-
.
IV-1-1
1. Portal
Portal ,
. ()
() ,
/, . 1-1. ,
Portal.
1-1.
/
1-2. Portal
1
2
3
1-1. Portal, ,
IV-1-2
. IP-
. , System Summary,
Diagnostics ().
.
. Menu ,
.
Eclipse
.
. System Summary,
.
System Summary Portal,
.
. ,
IP-, /
,
.
, ()
. , .
(//)
ToolTip. ToolTip ()
.
"" ,
. ,
. .
Portal /.
Portal /
.
/:
. Portal,
IDU.
IDU. IDU
, IDU ,
. Portal
/ .
Portal
Portal
Eclipse,
Portal, Provision V Eclipse. .
IV-1-3
1. Portal
. 1-2. ,
; , System Summary
.
1-2. Eclipse
NCC
RAC
FAN
DAC
DAC
NPC
ODU
AUX
IDU
IV-1-4
Eclipse
Portal
. 1-3 Portal
1-3.
IV-1-5
1. Portal
. , Portal,
.
1-4. Portal
IV-1-6
Eclipse
Eclipse
. 1-5
INU INUe Eclipse.
1-5. INU INUe Eclipse
INU
INU:
1, 2, 3 - RAC, DAC
AUX.
NCC
4 FAN
FAN NCC .
NCC
Fan
, RAC RAC/
DAC 155oM
.
INUe
5
8
4
7
NCC
1, 2, 3, 4, 5, 6 - RAC, DAC
AUX.
7,8,9 .
NMS ,
, DAC
AUX, ,
NMS.
DAC 155oM AUX ( DAC
NMS).
10 FAN
9
10
Fan
NCC
INUe:
FAN
Fan
6
9
FAN NCC .
, RAC RAC/
DAC155oM 1 4, / 2 5, /
3 6.
IV-1-7
INU/INUe IDU Portal,
/.
INU/INUe, .
, DAC, 3, DATA 3.
Portal
Portal , ,
.
Eclipse
. 1-6 .
1-6. Eclipse
RAC
RAC ODU.
Link
. Eclipse,
RAC, (ID) RAC
Link,
Link.
, Link
RAC.
, Link
RAC.
, Link Ring.
DAC
DAC. DAC - ,
, DAC 16x,
DAC 4x, DAC ES.
Data
Eclipse
Ring
, . Ring
RAC.
AUX
AUX. AUX
- .
NPC
.
NCC .
IV-1-9
1. Portal
Portal ( ), Portal
Eclipse. ,
Start Up Portal , Portal.
, Portal .
, Portal, ,
.
, ,
/ diff ,
c Eclipse V.24 Ethernet.
Ethernet . ,
.
Portal Auto Version
Portal Eclipse,
/. . Portal . 2-1.
V.24,
.
Portal
2.1.1; ,
Portal, , Eclipse.
, Harris Stratex (PB04-017, 1
2004 ), Eclipse
Portal 2.1.1 2.1.18.
Harris
Stratex Networks .
Harris Stratex Helpset
, .
Eclipse /,
Portal, .
IV-1-10
2. Portal
Portal
.
:
Portal . 2-1
Portal Eclipse . 2-3
Portal . 2-19
. 2-33
Portal
Portal
.
:
IBM-
P3 500
256
80
CD-
IV-2-1
2. Portal
- (1 2), USB-
USB/
V.24, Ethernet 10Base-T LAN RJ-45
Ethernet-.
800 600, 256 ( 16
)
SVGA
256
2 3
101-
Portal, :
Microsoft Windows 98, 2000 Pro, XP Microsoft Windows NT
TCP/IP LAN
Portal
Portal ,
Eclipse.
Portal :
1. Eclipse (
: 857-000004-001).
2. Portal .
3.
.
Portal Portal
Java Runtime. Portal .
Portal . Portal Auto Version
Portal Eclipse. .
Portal Auto Version . 1-9.
IV-2-2
Eclipse
Portal Eclipse
Eclipse, IDU, ,
IDUsp, -Eclipse; 10/100Base-T
Ethernet V.24.
, IDUsp, c Portal
Ethernet..
Portal
() /,
V.24 ,
V.24. IP-,
Ethernet.
, V.24
, IDUsp, Portal
Ethernet, , DHCP (Dynamic Host Communications
Protocol).
Ethernet,
V.24. Ethernet
.
Portal . 2-1.
:
Ethernet- LAN- TCP/IP
.
Ethernet- DHCP.
V.24.
Portal Ethernet
DHCP- IDUsp.
Eclipse.
IV-2-3
2. Portal
2-1. Portal
Eclipse
TCP/IP- Ethernet
Eclipse, ,
V.24. TCP/
IP- ,
V.24.
Ethernet TCP/IP, :
IP- / Eclipse,
.
LAN NMS
/. /
NMS-
IP-, TCP/IP ,
/
Eclipse. . TCP/IP . 2-6.
:, Ethernet-
NMS Eclipse F.
Eclipse,
V.24,
Eclipse.
DHCP- IP- /.
:
DCHP-.
DHCP (
IP-).
:
IV-2-4
Eclipse
Eclipse
V.24
V.24 Eclipse,
V.24. V.24-
IP- /.
V.24 /.
V.24 /
. IP-,
Ethernet-, - /
.
:
c Portal
Eclipse Ethernet- :
Ethernet . 2-5
TCP/IP . 2-6
Ethernet
Eclipse
Ethernet :
LAN- 10Base-T 10/100Base-T,
.
IP- Eclipse,
.
IP- , .
Eclipse. .
TCP/IP . 2-6.
IV-2-5
2. Portal
Eclipse,
, IP-
, V.24
/.
IP- / Eclipse,
V.24,
V.24 IP- Ethernet
. 2-32.
IP- / Eclipse,
V.24, DHCP-
, DHCP-
. 2-24.
Eclipse ,
IP- ,
/.
192.168.255.0 192.168.255.255,
()
Eclipse.
Ethernet ,
IT-.
TCP/IP
Portal LAN-- .
/ Eclipse ,
LAN ,
TCP/IP ,
/.
TCP/IP LAN- ,
LAN NMS Eclipse.
Windows 2000 XP
: Windows 2000
Windows 2000,
Windows.
, ,
- TCP/IP . 2-8.
IV-2-6
Eclipse
1. LAN ( )
,
.
LAN
, Control Panel ( )
Network and Dial-up Connections ( ) > Local Area
Connection ( ).
Local Area Connection Status (
).
2. Properties ().
3. Internet Protocol (TCP/IP) ( (TCP/IP)).
4. , .
5. Properties ().
Internet Protocol (TCP/IP) Properties (:
(TCP/IP)).
- ,
, LAN
.
IV-2-7
2. Portal
7. IP / IP :
IP- , /
, .
. ,
,
255.... ,
10.16 ( 255.255.0.0).
IP- ,
/ IP .
, /,
.
, /,
.
- TCP/IP . 2-8 .
8. /
Eclipse , - IP- /
Eclipse, .
DNS-c .
9. OK, OK .
/ Eclipse .
:
Portal . 2-19.
- TCP/IP
TCP/IP
,
.
Eclipse, , IP- 192.168.10.1
255.255.255.0. ,
IP- 192.168.10, - 1.
IV-2-8
Eclipse
TCP/IP
TCP/IP
IP- .
Default gateway ( )
, /
9500 MXC .
:
:
- Obtain an IP address automatically
( IP- ),
- Obtain DNS server address
automatically' (
DNS- )
,
(
). Use the following IP
address (
IP-), IP-.
IP-
192.168.10.1
192.168.10,
, .2.
Default gateway ( )
IP- Eclipse,
Portal /
Eclipse .
IV-2-9
2. Portal
DHCP - "-",
IP- ,
LAN. IP-
, IP-
TCP/IP , . ,
Obtain IP Address Automatically ( IP-
) TCP/IP.
DHCP IP-
. Eclipse,
Portal.
Portal ,
( NMS 10/100Base-T Ethernet
Eclipse), 30 (30
DHCP- Eclipse).
DHCP -
TCP/IP .
, Portal,
IDUsp ( Eclipse,
DHCP-), :
Ethernet DHCP
TCP/IP DHCP
Ethernet DHCP
Ethernet DHCP Portal
:
IV-2-10
Eclipse
TCP/IP DHCP
Portal
IP-, Local Area Connection (
) .
Windows 2000,
Windows.
1. LAN ( )
,
.
LAN
, Control Panel ( )
Network and Dial-up Connections ( ) > Local Area
Connection ( ).
Local Area Connection Status (
).
2. Properties ().
3. Internet Protocol (TCP/IP) ( (TCP/IP)).
4. , .
IV-2-11
2. Portal
5. Properties ().
Internet Protocol (TCP/IP) Properties (:
(TCP/IP)).
- ,
, LAN
.
Portal V.24
, ,
COM- DB-9,
USB-.
Windows XP, ,
USB-, COM- DB-9.
USB-,
USB- .
Portal
IV-2-12
Eclipse
Eclipse V.24 :
V.24 COM-
DB-9. . 2-13
V.24/RS-232 USB-
. 2-15
V.24
COM- DB-9.
,
COM-.
Windows 2000/98 XP
Windows 2000 Windows 98 :
Eclipse
COM-: Windows 2000 98, ;
COM-: Windows 2000 98.
Windows XP :
COM-: Windows XP.
Eclipse COM-:
Windows 2000 98
V.24/RS-232, :
1. , Phone and Modem Options
( ) > Modems () > Add ().
.
2. Next ().
3. Don't detect my modem; I will select it from a list (
( )) Next ().
4. Have Disk ( )
Eclipse.
5. Eclipse V.24 Modem Driver.inf, Open
().
6. Eclipse V.24 Modem [38400bps] Next ().
7. COM- Next ().
8. Digital Signature Not Found (
), Yes ().
IV-2-13
2. Portal
9. , Finish ().
10. .
COM-: Windows 2000 98
,
:
1. , Network and Dial-up Connections
( ) > Make New Connection (
).
.
2. Next ().
3. Dial up to private network ( )
Next ().
4. - Eclipse V.24 Modem [38400bps] Next
().
Eclipse V.24 Modem - ,
.
5. Next ().
6. , .
7. Add a short cut to my desktop (
).
8. , Finish ().
, ,
Portal . 2-19.
COM-: Windows XP
Portal Eclipse. Windows 2000/98
.
, :
1. , Network and Dial-up Connections
( ) > Make New Connection (
).
.
2. Next ().
IV-2-14
Eclipse
V.24/RS-232
USB-
Windows XP. ,
Windows 98, 2000.
XP.
, USB/
, , Radio Shack Edgeport.
, .
,
-,
Windows XP.
USB- :
USB/
-,
V.24 USB
V.24 USB
USB/
USB-/-
, :
IV-2-15
2. Portal
1. USB/ USB-
.
.
2. Windows XP,
. 6.
3. CD USB .
4. Install from a list or specific location (Advanced) (
()) Next
().
5. Search Removable Media (
) Next ().
(), .
,
, Windows
Windows XP. ,
6. Next ().
USB .
7. , Finish ().
USB-to-Serial . Windows XP
COM- .
8. Start () > Settings () > Control Panel (
).
9. System () Hardware
().
10. Device Manager ( ),
Ports () (COM & LPT).
USB to Serial
OM-, , , RadioShack
USB to Serial Cable (COM3).
11. -
.
-,
-
USB-,
COM 1. , ,
COM- (
).
IV-2-16
Eclipse
-port, :
1. USB to Serial,
Properties ().
2. Port Settings ( ) Advanced
().
3. COM- .
4. OK OK Device Manager (
).
5. OK,
System Properties ( ).
USB-
COM-.
USB-,
.
:
4. Have Disk ( )
Eclipse, Eclipse V.24 Modem
Driver.inf. Open ().
5. CDROM OK.
6. This driver is not digitally signed (
),
Next().
7. USB/
COM-,
USB/ . 2-15, Next ().
IV-2-17
2. Portal
8. USB-
, ,
Windows Windows XP.
Continue anyway ( ).
9. Finish (), OK .
V.24 USB
,
V.24 USB, :
1. Start () > Settings () > Control Panel (
).
2. Network Connections ( ).
3. Create a new connection (
), .
Next () .
4. New Connection Type ( ),
Connect to a network at my workplace (
) Next ().
Portal . 2-19
IV-2-18
Eclipse
Portal
Ethernet,
LAN; Portal . 2-20
.
LAN
Eclipse . 2-19.
V.24,
Eclipse. . Portal
V.24 . 2-12.
Eclipse . 2-19.
Eclipse, , IDUsp,
V.24. Portal
Ethernet, DHCP-.
Eclipse
Ethernet
LAN- 10/100Base-T NMS
Eclipse LAN RJ-45 RJ-45.
Mdi () MdiX (-).
Eclipse 10/100Base-T NMS NCC.
.
Eclipse 10/100Base-T NMS IDU.
IDU .
V.24
V.24 DB-9 RJ-45,
V.24
NCC IDU.
IV-2-19
2. Portal
Portal
Ethernet V.24.
:
TCP/IP . 2-20
DHCP Ethernet . 2-22.
V.24 . 2-25
. 2-27
. 2-28
. 2-30.
. 2-31.
V.24 . 2-31.
V.24 IP- Ethernet
. 2-32.
Portal, Ethernet V.24
Eclipse.
,
90 .
Portal, Portal
.
TCP/IP
LAN IP-.
Eclipse, DHCP-,
,
.
1. NMS 10/100Base-T Eclipse
, .
2. , TCP/IP Portal ,
LAN, ,
.
3. Portal. . . 2-1 . 2-22.
IV-2-20
Eclipse
IV-2-21
2. Portal
1
2
IP- ,
. ,
,
. . 2.
IP-
; . IP-
, ,
LAN Portal
().
IP-, Connect to.
Connect,
.
. . .
DHCP Ethernet
, ,
() Eclipse, ,
DHCP-.
IV-2-22
Eclipse
DHCP-.
Eclipse V.24
DHCP-.
Eclipse DHCP- (
Networking).
, DHCP-,
TCP/IP Portal
IP-, DHCP . .
Portal Ethernet DHCP . 2-10.
, V.24
(, IDUsp) DHCP-,
DHCP-, DHCP.
. DHCP- . 2-24.
, V.24,
DHCP- .
DHCP- ,
Portal
DHCP- - IP- ,
LAN
IP- TCP/IP Portal.
, DHCP-
DHCP- . 10-17 IV, 11.
DHCP: DHCP-
Eclipse,
DHCP-.
1. ,
IP-.
2. NMS 10/100Base-T Eclipse
, .
3. Portal. . . 2-1 . 2-22.
4. .
IP-
; .
IV-2-23
2. Portal
(
NMS
), IP-
. ,
, IP- Connect-to.
,
NMS
( LAN),
/ .
, IP-
Connect-to.
5. , Connect
(). Portal,
, ,
. .
. 2-27.
,
. .
. 2-28.
6. Portal System Summary.
(System
Summary) . 15-2, IV.
, IDU, V.24,
DHCP- 169.254.2.1
169.254.254.255 255.255.0.0.
DHCP-
,
V.24,
DHCP-. DHCP-,
DHCP- ,
. ,
Portal.
DHCP ,
DHCP-,
.
1. ,
IP-.
2. NMS 10/100Base-T Eclipse
,
90 .
IV-2-24
Eclipse
3. DHCP-,
, (status LED) IDU ODU
, .
, 5
10 .
, .
5 ,
DHCP-. ,
.
10 ,
,
-
.
. 2-55, II, 2.
4. Portal. . . 2-1 . 2-22.
DHCP-. .
DHCP: DHCP- . 2-23.
DHCP- 5
, .
DHCP- Networking, Portal
.
5 IP-
IDU DHCP-.
IP-
Send, ,
Portal. ( Windows , ,
).
V.24
Eclipse,
V.24.
, :
1. Dial Up / Network
Connections,
V.24.
Windows 2000/98 Dial Up Connection Status (
).
IV-2-25
2. Portal
6. , Connect
().
. . . 2-27.
,
. .
. 2-28.
7. Portal System Summary.
(System
Summary) . 15-2, IV.
IV-2-26
Eclipse
V.24
V.24
IP- 192.168.255.225.
,
V.24.
IP-
; .
,
Portal .
Connect,
.
. .
.
Connect (),
Portal ,
Portal , Eclipse.
IV-2-27
2. Portal
Auto version ,
:
Portal...
Portal...
<>. <>.
Portal...
Portal Auto Version Portal Auto Version
. 1-9.
, /
, Connect . .
. 2-28.
,
Diagnostics > System Summary.
(System Summary) . 15-2,
IV.
/ Eclipse ,
Connect.
2-3.
1
2
IV-2-28
Eclipse
2-4.
: admin,
engineer operator, .
.
.
1 /
Harris Stratex Networks.
2 ,
Harris Stratex Networks.
. 2-5
.
2-5.
admin
()
.
/, .
Eclipse,
.
engineer
()
/.
Eclipse ,
.
operator
()
.
Eclipse ,
.
IV-2-29
2. Portal
Eclipse, :
1.
.
2. Connect ().
Portal Diagnostics > System Summary.
14.
/ ,
Security . 14-1.
,
.
(
), Harris Stratex Networks
.
/.
Harris Stratex Networks
,
.
1. Options Username and Password,
Reset Passwords. . . 2-3.
2. Save As 1,
. Save.
(.txt) , /
.
3. Harris
Stratex Networks (). ,
.
4. Harris Stratex Networks , ,
,
.
5. Username and Password,
Open. 2.
IV-2-30
Eclipse
, .
6. Reset radio password, .
,
/.
14.
Portal ,
IP-, Eclipse Portal Start up Connect , .
, ,
.
Auto Version
.
V.24
,
Maintenance Port ( ), Connect,
, :
.
IP- V.24.
V.24 IP- ,
Eclipse.
V.24 - ,
, Portal.
IP- V.24 ,
, Networking IP Addressing >
Advanced. 10. .
IP- : 192.168.255.225
IP- V.24
1. .
2.
IV-2-31
2. Portal
, .
5. IP- -
192.168.255.225, .
6. Dial-up Connection Status (
).
7. Portal IP Address, IP-
Connect ().
V.24 IP-
Ethernet
Ethernet, DHCP-
/ Eclipse IP- ,
, .
,
V.24, , IDUsp.
IV-2-32
Eclipse
1. V.24 /.
2. Configuration > Networking,
IP-.
Single IP Addressing ( IP-)
IP- .
Interface Addressing (Advanced) (
()), IP- - Ethernet-
IP-
,
Eclipse . 10-2
3.
Ethernet-
4. IP- 2 Connect.
. 2-6 Portal.
2-6.
Portal
Cc
System Summary
(System
Summary) . 15-2, IV.
. 3-8, III
IV, 15.
IV-2-33
3.
Portal ,
:
Eclipse
Eclipse Eclipse
Eclipse
.
,
,
.
:
Eclipse INU INUe ODU 300 / ODU 100
Eclipse IDU ODU 300 ODU 100.
:
. 3-2
Portal . 3-5
. 3-8
. 3-12
IV-3-1
3.
Portal Backup () Restore
() .
File > Backup / (
Send) .
File > Restore
/.
Portal .
" ", 13.
Configuration Not Supported
( ) Configuration Corrupt
( ) Event Browser Alarms.
ODU
ODU RAC
IDU , INU/INUe,
RAC . ,
:
ODU.
, /
.
,
Eclipse ,
, ,
ODU .
, ,
, /
. .
. 7-4.
, RAC
.
IV-3-2
Eclipse
, ,
,
()
Send.
, Portal,
CompactFlash, ,
( Send).
Send ( /),
CompactFlash.
, ,
,
, , Send.
/
, (Tx)/ (Rx), /
(Tx) (Tx)
Portal RAC/ODU ( Eclipse), /ODU
( Eclipse).
.
Eclipse
(RAC). CompactFlash,
().
IDU Eclipse .
, IDU CompactFlash:
IDU ES
Ethernet. 50 /, c
200 /c 50 /c.
IDU 300 20xV2 Eclipse
20xE1/28xDS1 40xE1 32xDS1.
, System Summary Plug-ins,
(Plug-in)
. ,
.
, System Summary - .
IV-3-3
3.
IV-3-4
Eclipse
Portal
File :
New Portal, Portal
/.
.
Backup () /
( Send)
.
Restore
, /.
Edit :
ut (), copy (), paste from/to ( /
) Portal,
Portal .
Preferences ()
:
( (On) ).
- ( (Off)
).
( (Off) ).]
CSV. ,
CSV.
, , .
Installation :
Licensing () ( Eclipse, IDU ES, IDU 300 20xV2).
As-built report ( ).
Configuration :
.
.
.
CompactFlash.
IV-3-5
3.
Diagnostics :
INU/INUe.
, , (Tx),
BER.
.
.
( Eclipse).
.
Help :
,
Harris Stratex Networks.
Portal.
Refresh Send
Refresh () ,
.
, Refresh (),
.
Send () :
CompactFlash. ,
Send, - Send
. ,
Send, -, ,
, ,
. Send ,
, .
. 3-1 Eclipse.
IV-3-6
Eclipse
3-1. Portal
IV-3-7
3.
,
( IP-).
1. ,
, / Eclipse
.
3 Eclipse.
2. / , .
INU/INUe/IDU 90 ,
Portal.
, Portal cannot
determine the type of terminal at....(Portal
....) ,
Portal.
3. Portal Eclipse Portal Start Up:
,
V.24,
V.24. ( IP- ,
Ethernet,
).
, V.24,
DHCP-. 10/
100Base-T NMS Ethernet- (Mdi MdiX).
() ODU
,
.
,
. ,
, . .
. 7-4. , ,
RA ,
.
INU/INUe RAC
, ODU
RAC.
IV-3-8
Eclipse
4. :
Eclipse
Eclipse
:
IDU ES Ethernet 50
/c .
,
,
6. ,
RAC
.
IDU300 20xV2
20xE1/28xDS1
Installation > Licensing
.
. Connect ES . 4-3
IDU 300 20xV2 . 4-5.
. 4-2.
5. :
Eclipse
Eclipse
. 6-1.
. 6-1.
6. :
Eclipse
Eclipse
System Summary ,
IDC,
.
( ).
,
.
(, , )
.
(System Summary)
. 15-2.
IV-3-9
3.
7. :
Eclipse
Eclipse
,
,
. Tx Mute (
), .
, ,
. Tx
Mute ( ),
.
. 7-1.
. 7-1.
8. :
Eclipse
Eclipse
. 8-1.
. 8-23.
9. :
Eclipse
Eclipse
. 9-1.
IDU ES Circuits -
Ethernet-
. Configuration >
Circuits .
. 9-1.
10. :
Eclipse
Eclipse
. 10-1.
. 10-1.
IV-3-10
Eclipse
11. :
Eclipse
Eclipse
Eclipse . 11-1.
Eclipse . 11-1.
12. : /
Eclipse
Eclipse
. 12-1
. 12-1
13. :
Eclipse
Eclipse
. 13-1.
. 13-1.
14. :
Eclipse
Eclipse
. 14-1.
. 14-1.
15. RSSI
IV-3-11
3.
Eclipse
. 5-1.
20. .
.
/
, ,
() ,
. ,
()
:
Portal File > Backup,
/ ( Send)
.
File > Restore,
/.
, .
IV-3-12
4.
IV-4-1
4.
. 4-3
. 4-7
. 4-9
;
.
, .
CompactFlash
CompactFlash,
( CompactFlash - ).
NCC IDU. CompactFlash
.
CompactFlash
Eclipse,
/ (
).
,
CompactFlash.
:
Connect ES
IDU 300 20xV2
10xE1/16xDS1 RAC
"
IV-4-2
Eclipse
DS
STM1/OC3
1xSTM1/OC3, 2xSTM1/OC3.
, RAC
,
. , 52xE1
NxE1, 56xDS1, 3xE3,
3xDS3, 1xSTM1 1xOC3.
RAC/ODU
,
,
.
. , 64xE1
RAC/ODU
.
RAC/ODU, ,
- RAC/ODU.
, Portal
,
,
. ,
201 : 16QAM QPSK.
Connect ES
Connect ES Eclipse
50 /c. ,
IV-4-3
4.
, .
Connect ES. (
CompactFlash IDU ES).
. , E1-
DS1- ,
.
. 4-1 ETSI, . 4-2 ANSI.
's' Connect ES
ODU 300sp. s ODU 300ep ODU
300hp.
Connect ES ODU 300ep ODU 300hp
Connect ES 50. Connect
ES 100, Connect ES 150 Connect ES 200.
Connect ES ODU 300sp Connect ES
40s. Connect ES 80s.
Connect ES 50 ETSI,
20 40 /c.
onnect ES 50.
, ,
Connect ES,
II, 2.
4-1. ETSI
IV-4-4
Connect
Connect ES 40s
40 /
201
Connect ES 80s
80 /
+
40 /c.
401.
Connect ES 50
50 /
321
Connect ES 100
100 /
+
50 /c.
521.
Eclipse
Connect
Connect ES 150
150 /
+
100 /c.
751.
Connect ES 200
200 /
+
150 /c.
1061.
4-2.
ANSI
Connect
Connect ES 50
50 /
32DS1
Connect ES 100
100 /
+
50 /c.
70DS1
Connect ES 150
150 /
+
100 /c.
100DS1
Connect ES 200
200 /
+
150 /c.
127DS1
20xE1
40xE1
IV-4-5
4.
DS
28xDS1
32xDS1
IV-4-6
Eclipse
Licensing Installation > Licensing.
. 4-1 .
, ,
.
Licensing
RAC.
RAC.
RAC,
10xE1 16xDS1.
RAC
RAC, RAC
INU INUe.
IDU ES IDU 300 20xV2 Licensing ,
, .
4-1. Licensing Eclipse
1
2
IV-4-7
4.
4-3. Portal:
.
CompactFlash - .
Status "active".
Status "failed" . ,
CompactFlash ,
( - ). CompactFlash,
INU/INUe, IDU, .
:
RAC Plug-in RAC INU/INUe.
Licensed :
/c ,
RAC/
.
/c ,
RAC/
.
/ RAC
Plug-in / RAC (
INU/INUe).
Max Capacity ,
RAC/.
. ,
. . .
: License ( 3,6)
,
: .
IV-4-8
Eclipse
,
Harris Stratex Networks. ,
, ,
.
. ,
CompactFlash,
CD.
,
,
.
web-.
1. , Harris Stratex Networks,
.
,
.
CompactFlash
Portal ProVision.
,
. ,
( ),
, , .
IV-4-9
4.
:
,
() RAC.
, RAC RAC INU
INUe
.
,
,
RAC (
, , ).
.
,
, .
IDU
IDU,
IDU.
,
CD - .
2. ,
,
. ,
.
3. ,
Portal, /,
. ,
CompactFlash,
. 4-10.
IV-4-10
Eclipse
1. Portal
Portal C:\Program Files\Portal
, , C:\Program
Files\Portal\License.
2. / Licensing
Select a New License ( ).
Select License,
() , Portal :
4-2.
1
2
3
4-4. :
, Portal
. , . ,
/.
,
. , Change,
.
Select License, .
Send, .
IV-4-11
4.
( ),
/.
CompactFlash.
()
Licensing.
IV-4-12
5.
Reports Installation.
, (as built report)
(helpdesk data file).
. . Reports . 5-2.
csv,
Excel- .
/
.
. ,
,
.
, .
.
, ,
Stratex
Networks .
Eclipse
Stratex Networks,
.
,
.
IV-5-1
5.
/ ( - ), .
, ,
; Advanced
Management . 15-75 "", IV, 16.
(),
Portal C:\Program Files\Portal\Reset Logs\.
Reports
:
. 5-3
. 5-3
5-1. Reports
5-1. Reports:
IV-5-2
Save, .
Eclipse
,
Save .
Excel. ,
:
- , /
.
- ,
Portal, Portal.
,
.
Portal, ,
, , csv
not defined ( ). ,
Portal,
. ,
csv.
, , , Portal.
Portal,
not defined.
csv,
" " Excel.
.
csv , Eclipse
Commissioning Forms ( Eclipse).
Excel ( )
Eclipse.
IV-5-3
5.
Stratex Networks.
(
Advanced Management . 15-75 "", IV,
16),
Portal - C:\Program Files\Portal\Reset
Logs\.
Eclipse .
IV-5-4
6.
Information
, . . . 6-1.
6-1. Information
Portal.
NCC (
NCC - )
System Summary
NCC Rename
().
IV-6-1
7.
. 7-1.
DATA
PDH SDH. DATA DAC/IDU
, - .
DAC Ethernet DAC
Ethernet IDU ES.
AUX
:
Plug-ins . 7-2
. 7-4
DAC/ . 7-26
AUX . 7-92
IV-7-1
7.
Plug-ins
, Plug-ins
( ). . 7-1 . 7-2, 1
RAC, RAC 1 .
, Plug-in .
Plug-in, .
. 7-1 . 7-2 Eclipse.
,
. NCC FAN,
Portal.
. 7-1. Eclipse
Link
1. Plug-in
.
.
IV-7-2
Eclipse
IV-7-3
7.
, RAC
(), 2 RAC () ODU.
,
, IDU 2 IDU
ODU.
, RAC/ODU
Ring (), Link ().
/ Portal
()
RAC DAC 155oM LINK, RING DATA
( , System
Summary Plug-ins) Launch Remote (
).
:
/ . 7-4
. 7-13
. 7-18
. 7-20
ATPC . 7-21
/
Eclipse, Link/Ring
, / ,
, - (TR), (Tx) ATPC.
Eclipse, ,
.
/ . 7-7
XPIC :
XPIC
IV-7-4
Eclipse
,
Protection.
, IV, 8.
:
. 7-13.
.
. 7-18.
Eclipse RAC,
, RAC
,
. . 7-3 . 7-20
RAC.
Eclipse
IDU. IDU
. ,
IDU ,
.
,
, . .
. 7-20.
IV-7-5
7.
XPIC
RAC 40 XPIC
, RAC;
RAC.
, (Tx)
/ .
64/75xE1, 70/
84/100xDS1, STM1.
27.5/
28 ( ) ETSI,
30 ANSI.
ATPC .
RAC 40 Polarization
Setting Protection Settings.
(
) - RAC 40.
. . 7-2 ,
IP- INU .
Diagnostics > Performance
RAC 40,
RAC 40 (
). , XPIC RAC
40, .
. 7-2. Polarization Settings
.
. 7-6 . 7-17.
IV-7-6
Eclipse
/
,
, , .
. 7-3
16xE1, 16 QAM.
. 7-4 . 7-15.
Protection Setting,
.
Plug-ins . 7-5 .
7-16. Protection Setting,
.
.
7-6 . 7-17.
:
. 7-13
. 7-20
IV-7-7
7.
. 7-3.
/ .
(RAC/ODU).
.
1 ,
.
,
( Circuits).
IV-7-8
/
. , .
Eclipse
:
(Tx) (Rx),
.
ATPC.
(Tx) ().
(Tx),
(Tx) (Tx), (Tx)/
(Rx) ODU.
.
1.
:
1. Plug-ins .
, RAC (
) LINK
RING.
,
.
,
RAC , , (Tx)
ATPC .
, /
.
2. . Capacity
.
RAC/ODU IDU/ODU.
.
,
, , IDU 20x IDU ES,
, .
IV-7-9
7.
3. /. /
.
/ ,
RAC/ODU IDU/ODU.
, Ring
(), /
RAC.
Eclipse: QPSK, 16QAM,
32QAM, 64QAM, 128QAM 256QAM, Bandwidth/Modulation
,
RAC. ,
16xE1 Bandwidth/Modulation 28 / QPSK
14 / 16QAM. , ,
IDU/IDU
.
4. (RAC 40), ,
Polarization Settings.
IV-7-10
Eclipse
RAC 40.
5. Frequency (). (Tx),
(Tx) (Tx),
(Tx)/ (Rx) ODU.
.
(Tx) / (T/R)
(Rx). (Tx)
250 .
250 . (Tx)/(Rx)
.
(Tx)/(Rx)
ODU (Tx),
(Tx).
(Rx) ,
, (Tx)
,
(Tx)/ (Rx).
(Tx)/ (Rx).
(Tx)
(Rx) /
, .
ODU 5 ,
Tx High ( ) Tx Low (
). Tx Frequency Band ( )
. ODU
(Tx).
6. Tx Power ( ),
0,1 .
IV-7-11
7.
ATPC.
Detected Tx Power (Tx)
ODU, (Tx).
+/-2 .
ATPC .
ATPC, . .
ATPC . 7-21.
7. Factory Tx Mute .
. ,
,
,
(Tx) , , .
8. .
Link Ring System Summary,
Rename () . unnamed.
Link Ring Portal,
. : Plug-ins,
Protection, Circuits, Networking, System Summary, System/Controls,
History.
IV-7-12
Eclipse
. 7-2 Eclipse.
. ,
RAC/ODU ,
.
IDU 300 8x/20x IDUsp 16x
. (Rx)
.
IDU 155o IDU 300 20x
.
(Rx)
- IUD ,
.
LINK RING,
/ Protection.
. 7-2.
, ODU,
,
.
, ODU,
,
. RAC/ODU
, ,
.
,
ODU. RAC/ODU IDU/ODU
.
,
IV-7-13
7.
, ODU;
, .
, ODU
(Tx)
(Tx) ( ).
,
E1
DS1- .
Plug-ins
,
Protection.
, .
,
, .
IV-7-14
Eclipse
. 7-4. Plug-ins
STM1-: RAC
1 4, RAC 1 - , RAC 4 - .
/
,
Path Settings.
Protection Settings ,
, .
IV-7-15
7.
. 7-5. Plug-ins
1
2
IV-7-16
STM1-,
RAC 1 4.
East () West () ,
/.
East West
.
Protection Settings ,
.
Eclipse
. 7-6. Plug-ins
, RAC 1 2, RAC 1 RAC, RAC 2 - .
2, 3
/ ( ),
Link Settings Path
Settings.
,
ATPC.
Protection Settings
( ),
.
IV-7-17
7.
- RAC .
,
-.
- RAC 1 RAC 2 ,
IP- INU
- RAC 40.
, ,
Protection.
, Plug-ins
. ( )
.
Plug-ins Protection Settings :
, Protection
IV-7-18
Eclipse
(
), Coupler Loss
(RAC).
;
(Tx) RSL. ,
.
;
3,5 ,
,
1,5 / 6,5 .
. 7-4 . 7-20.
,
RAC. ( RAC
RAC/ODU,
)
-.
(Tx) (Rx). ,
1,6 ,
"-" -
3,2 .
,
( RAC 4), ,
- RAC .
;
.
:
- ATPC .
- .
- RAC
.
IV-7-19
7.
. 7-3. RAC
C RAC
, , ,
, ATPC
, , ,
, ATPC
. 7-4.
37.0 - 40.0
4,0 ()
4.0
2,0 ()
7.0
31.9 - 33.4
3,8 ()
3.8
27.5 - 31.3
1,8 ()
6.8
17.7 - 19.7
3,6 ()
3.6
14.4 - 15.35
1,6 ()
6.6
3,5 ()
3.5
1,5 ()
6.4
24.25 - 26.5
21.2 - 23.6
12.75 - 13.25
10.7 - 11.7
7.11 - 8.5
5.925 - 7.11
4.0 - 5.0
IV-7-20
Eclipse
ATPC
ATPC ,
(RSL) . ATPC
,
, ,
,
.
,
, , ,
.
( RAC ),
RSL, RAC.
ATPC
. ,
, ,
,
, ,
( )
. /
(Tx) ATPC, ,
( ),
.
ATPC:
, ,
.
.
.
,
.
ATPC
,
ATPC.
ATPC
RSSI 56 ,
,
IV-7-21
7.
1. ,
( )
.
, , ATPC
.
ATPC RSL. ,
RSL, ATPC.
(Tx)
RSSI/RSL .
XPIC ATPC.
, ATPC,
RSL (Tx)
1.
1.
ATPC , , ,
ATPC. ,
C/I . ATPC,
C/I , (Tx)
ATPC, 10-6 . ,
, ATPC.
ATPC ,
, ,
.
, ATPC ; ,
,
ATPC.
ATPC
,
, ,
, ,
, Target Fade Margin ( )
.
, , Remote Fade Margin
( ) Detected Tx Power (
) +/- 3
,
(Tx) ATPC.
1
RSSI /
. Eclipse ETSI
FCC .
IV-7-22
Eclipse
. 7-7. ATPC
1
2
3
4
5
6
(Tx)
(Tx)
(Tx)
IV-7-23
7.
. 7-5. ATPC
RAC/ODU
/ODU. ,
,
,
.
.
RSL SNR
100 .
, RSL SNR
10-6
. RSL SNR
Target Fade Margin,
ATPC (Tx) (
). RSL / SNR
, (Tx)
,
(Tx).
, RSL / SNR ,
(Tx)
,
(Tx).
Target Remote Fade Margin Remote Fade Margin
2 .
:Eclipse 6 .
Max Tx Power
(Tx)
.
. ,
,
,
,
.
Min Tx Power
.
,
.
IV-7-24
Eclipse
Detected Tx Power
/ (Tx). ATPC
, (Tx),
(Tx) (
). ATPC ,
Detected Tx Power 1,5
(Tx) (Tx Power).
ATPC:
1. Max Tx Power
.
Min Tx Power .
2. Remote Fade Margin ,
.
3. Max/Min Tx Power Target Remote Fade Margin,
Send ().
4. Remote Fade Margin
, 3
.
5. Detected Tx Power ,
3
.
6. Max Tx Power, ,
. ,
, .
, 7
Detected Tx Power, ATPC
.
7. Min Tx Power
() Detected Tx Power, ,
3 - 6 Detected Tx Power.
,
(Tx).
8. , Send ().
IV-7-25
7.
DAC/
Eclipse, DAC
TDM-. DAC
NxE1/DS1, NxE3/DS3, NxSTM1/OC3 Ethernet 10/
100Base-T. DAC
DAC .
Eclipse,
IDU.
IDU, NxE1 NxE1/DS1,
, DAC 4x DAC
16x Eclipse. IDU
, ,
.
IDU 155o,
, DAC 155o.
IDU ES, ,
DAC ES, Ethernet-,
, DAC 4/16x
.
. 7-6 DAC Eclipse, ,
DAC .
. 7-6. DAC
IV-7-26
DAC 16x
16xE1/DS1
DAC 4x
4xE1/DS1
DAC 3xE3/DS3
1/2/3xE3/DS3
DAC 3xE3/DS3M
1/2/3xE3/DS3, 2xE3
3
2x34 /c
DAC 1x155o
1xSTM1/OC3
DAC 2x155o
2xSTM1/OC3
DAC 155oM
1STM1/OC3
NxE1/DS1
Eclipse
DAC 2x155e
2xSTM1
DAC ES
10/100Base-T Ethernet
DAC GE
Gigabit Ethernet
:
. 7-27
. 7-27
DAC 16x, DAC 4x IDU E1/
DS1 . 7-30
DAC 3xE3/DS3 . 7-34
DAC 3xE3/DS3M . 7-36
DAC 1x155o, 2x155o 2x155e . 7-40
DAC 155oM . 7-45
DAC ES IDU ES . 7-54
DAC GE . 7-66
DAC. .
. 8-1 .
IV-7-27
7.
IDU. . . 8-23
.
: " " " ".
Tributary Protection ( ) (TT)
DAC/IDU
Y-.
(Rx) ( ) DAC/IDU
, DAC/IDU (Rx)
/.
(Tx), DAC/IDU
,
(Tx) .
Tributary Always On ( ) (TA)
DA/IDU
.
(Rx) ( ) DAC/IDU
, DAC/IDU (Rx)
/.
DAC/IDU
,
" " .
TA , INU/INUe Eclipse
DAC.
DAC/IDU .
- DAC/IDU (Tx)
(Rx).
, DAC
(Rx) (Tx), , ,
DAC (Tx), - (Rx).
DAC 155oM; ,
(Rx), (Tx)
DAC 155oM.
, (Tx) (Rx) DAC
(Tx) (Rx) IDU.
IDU
(Tx) (Rx)
(Tx) IDU, (Rx)
, (Tx) (Rx)
IDU.
IV-7-28
Eclipse
IV-7-29
7.
DAC 16x,
DAC 4x IDU E1/DS1
Eclipse,
DATA > DAC 16x DAC 4x.
Eclipse, DATA >
.
DAC 16x DAC 4x.
1
2
3
5
6
IV-7-30
1 DS1.
.
E1 DS1.
Eclipse
Tributary Lines :
Commissioned.
" "
(commissioned). " ",
LOS, LOS,
AIS, AIS.
Name.
/.
Impedance. 75 120
.
LOS
- .
, /
.
Fill Selection ()
,
.
DAC 16x, DAC 4x IDU
. 6-5 DAC Tributary Lines DAC 16x
(16xE1 16xDS1), E1
/
: / , ,
/
.
E1/DS1:
1. Plug-ins .
Eclipse
Eclipse
DAC,
Tributary Lines.
DAC,
Tributary Lines.
IV-7-31
7.
2. Tributary ( ): 1
DS1.
3. / Required Bus Type ( ).
,
.
Bus Configuration ( ) Circuits;
Required Bus Type, Circuits.
; Required Bus Type
.
Tributary Lines ( 4 6 ),
Select All ( ) Fill Selection (
), .
,
Select All,
, Fill Selection.
, Windows
(Ctrl+, Shift+ ),
, Fill Selection.
Fill Selection
.
4. ( ) Commissioned
, .
" "
:
DAC " "
.
IV-7-32
Eclipse
DAC, LOS - .
LOS
AIS
"
".
LOS
, LOS.
AIS
, AIS.
5.
Name . - .
System/Controls
DAC/ .
, ,
, Circuits,
,
Circuit Loopback (
) BER- .
6. /
.
1 Tributary Type,
75 , 120 .
DS1 Tributary Type,
.
DS1
AMI, B8ZS. , 655
. 100 .
7. (, )
DATA System Summary, Rename .
unnamed.
Send.
IV-7-33
7.
DAC 3xE3/DS3
DAC 3xE3/DS3 BNC female
75 E3 DS3
c E3 DS3, .
DAC 3xE3/DS3
. 7-9 Plug-ins,
/ : E3/DS3,
/,
.
. 7-9. DAC 3xE3/DS3
1
2
3
IV-7-34
3 DS3.
.
E3 DS3.
Eclipse
Tributary Lines :
Commissioned.
" "
(commissioned). " ",
LOS , LOS.
Name.
/.
/
. .
Fill Selection ()
,
.
DAC 3xE3/DS3
1. Plug-ins .
2. Tributary ( ): 3
DS3.
3. / Required Bus Type ( ) (E3
DS3). ,
.
Bus Configuration ( ) Circuits;
Required Bus Type, Circuits.
; Required Bus Type .
4. ( ) Commissioned
, .
" "
:
DAC " "
.
IV-7-35
7.
DAC, LOS - .
LOS
LOS
,
LOS.
"
".
DAC, LOS . ,
(
commissioned
()). ,
, ,
( ).
5.
Name .
System/Controls
DAC.
6. (, )
DATA System Summary, Rename .
unnamed.
Send.
DAC 3xE3/DS3M
DAC 3xE3/DS3M .
:
3xE3/DS3.
E13 13
2x E3 2x DS3 / 1/DS1-
.
E3
2x34 /c / 1- .
(Tx)/ (Rx)
, , 75 , mini-BNC
female. 3xE3/DS3. E13, M13
3, Tx/Rx 1 Tx/Rx 2.
DAC 3xE3/DS3M . 3-51,
II, 3.
IV-7-36
Eclipse
DAC, LOS . ,
(
commissioned
()). ,
, ,
( ).
DAC 3xE3/DS3M
. 7-10 Plug-ins.
. 7-10. DAC 3xE3/DS3M
1
2
5
6
IV-7-37
7.
Tributary Lines :
Commissioned.
" "
(commissioned). " ",
LOS , LOS.
Name.
/.
3xE3/DS3.
.
E3 DS3.
/
. .
Fill Selection ()
,
.
DAC 3xE3/DS3M
1. Plug-ins .
2. : 3xE3/DS3, E13/M13 Multiplexer
Transparent E3.
33/DS3
3xE3/DS3, ,
DAC 3xE3/DS3 . 7-34.
E13/M13 Multiplexer ( 13/M13)
13.
1. 13.
2. / Required Bus Type ( ).
13, ,
1. ; Required Bus Type
. ,
Required Bus Type, Circuits,
Bus Configuration ( ).
3. ( ) Commissioned
IV-7-38
Eclipse
, .
" "
:
DAC " "
.
DAC, LOS - .
LOS
LOS
,
LOS.
"
".
4.
Name ().
System/Controls
DAC.
5. (, )
DATA System Summary, Rename .
unnamed.
6. Send.
: Circuits,
- .
- - . 9-12, IV, 10.
34 /c
1. E3 Transparent.
2. / Required Bus Type ( ).
E3 Transparent,
3. ; Required Bus Type
. ,
Required Bus Type, Circuits,
Bus Configuration ( ).
3. ( ) Commissioned
, .
" "
:
IV-7-39
7.
LOS
LOS
,
LOS.
"
".
4.
Name ().
System/Controls
DAC.
5. (, )
DATA System Summary, Rename .
unnamed.
6. Send.
: Circuits,
- .
- - . 9-12, IV, 9.
IV-7-40
Eclipse
( ).
-15 -8 (
DAC 155o).
,
, .
. ,
.
.
IV-7-41
- STM1/OC3.
.
STM1.
Tributary Lines :
Commissioned.
" "
(commissioned). " ",
LOS , LOS.
Name.
/.
/
. .
Eclipse
...
LOS
LOS
,
LOS.
( (Tx)
).
"
".
4.
IV-7-43
7.
Name ().
System/Controls
DAC.
5. (, )
DATA System Summary, Rename .
unnamed.
6. Send.
: Circuits,
- .
- - . 9-12, IV, 9.
IV-7-44
Eclipse
DAC 155oM
DAC 155oM STM1/
OC3 155 /c / 63xE1 84xDS1.
NMS, DAC 155oM
1 6, INUe. INU;
.
DAC 155oM
. 7-12 Line Interface DAC 155oM.
. 7-13 . 7-47 Backplane Ports.
. 7-12. Line Interface DAC 155oM
2
5
3
6
1-
(STM1/OC3- / 63xE1-).
Bus Ports ( ),
() 63xE1 84xDS1.
. SDH
VC3 VC4.
IV-7-45
7.
:
Recovered STM1/OC3
(). .
Internal
.
.
BER 10-6 10-7 10-8.
, Events
Browser Alarms.
Tributary Lines :
Commissioned.
" "
(commissioned). " ",
LOS, LOS,
AIS, AIS.
Name. /
.
IV-7-46
/
. .
, .
Eclipse
1 DS1.
Circuits.
, :
Commissioned.
, :
AIS, RDI, LOP, LOM,
RPSLM,
VT/VC
" "
" ", .
Name. /
.
Bit Asynchronous ( )
Transparent Virtual Tribs (
) (TVT). TVT , DAC 155oM
Ethernet- DAC ES DAC GE (Ethernet
NxE1 NxDS1).
IV-7-47
7.
DAC 155oM
DAC 155oM :
Line Interface ( )
Bus Ports ( )
. 7-12 . 7-45 Line Interface DAC
155oM. E1 DS1 Backplane
Ports, 63xE1 84xDS1,
, 63xE1.
. 7-13 . 7-47 Bus Ports DAC 155.
DAC 155oM ,
PDH ,
. . . 8-1.
DAC 155oM, :
1. DAC 155oM New Module.
Line Interface
63xE1.
84xDS1,
Bus Ports, DS1 Bus Port Type.
2. Line Interface Frame Type ( ).
SDH with VC3 framing (SDH VC3)
,
SDH-, , :
, /, -. VC3
STM1,
21xVC12. VC12 11.
IV-7-48
Eclipse
IV-7-49
7.
commissioned, :
LOS
LOS
,
LOS.
AIS
(Tx)
.
AIS
,
AIS.
uncommissioned traffic alarm
( "
")
Events Browser Alarms.
/
.
, , System/
Controls DAC.
Status
/ . ,
. 7-12, ,
.
LC.
; .
1 (Class 1).
APAC Optotm:
-34 (. )
0 ().
: . -15 , . -8 .
(Tx) 1261 1360 ( 1310 ).
-35 (. )
IV-7-50
Eclipse
0 ().
: . -5 , . 0 .
(Tx) 1260 1355 ( 1310 ).
5. NMS Transport ( NMS).
DAC 155oM super PDH-
, NMS
SONET/SDH.
MSOH , Eclipse
NMS- (
).
DAC 155oM (
PDH- Eclipse SDH),
NMS SONET/SDH,
,
,
, D1-D3 (RSOH) D4-D12 (MSOH),
.
,
NMS-,
NMS Eclipse.
:
None ().
NMS Eclipse.
Use RSOH ( RSOH). NMS- Eclipse
Regenerator Section Overhead ( ).
Use MSOH ( MSOH). NMS- Eclipse
Multiplexer Section Overhead ( ).
6. Signal Degrade Threshold (
), BER.
,
Events Browser Alarms.
7. Bus Ports ( ).
8. Bus Port Type ( ).
E1 DS1:
E1 ( ), DAC 155oM
1xSTM1--63xE1.
DS1,
OC3--84xDS1.
Line Interface, Bus Ports.
IV-7-51
7.
9. Bus Ports, :
/, .
.
Bus Ports, Select
All ( ) Fill Selection ( ),
.
,
Select All,
, Fill Selection.
, Windows
(Ctrl+, Shift+ ),
, Fill Selection.
Fill Selection
.
commissioned, :
AIS, RDI,
LOP, LOM, RPSLM .
AIS, RDI,
LOP, LOM, RPSLM
.
VT/VC
unequipped ().
VT/VC
"
" "
",
.
/ ().
, , System/
Controls > Bus Ports DAC.
Signal Label ( ), ,
Bit asynchronous ( )
Transparent Virtual Tributary (
):
- Bit asynchronous ,
Ethernet-. ,
E1/DS1 ( )
SDH. ,
E1 DS1 .
IV-7-52
Eclipse
IV-7-53
7.
DAC ES IDU ES
DAC ES Ethernet- IDU ES.
Ethernet .
10/100Base-T
(), VLAN .
DAC ES Link () (RAC),
Ring () (RAC) Data ( ) (DAC 155oM).
IDU ES .
DAC ES
. 7-14 . 7-54 Plug-ins DAC ES.
Ethernet- IDU ES .
. 7-14. Configuration DAC ES
IV-7-54
Eclipse
, (
).
IV-7-55
7.
.
64 1536 .
C1 C2
48xE1 (98,3 /c).
1, 2
481.
IV-7-56
Eclipse
481 C1 C2
481 , 481 .
481 .
1 , C2
,
751 RAC 30, RAC 3x RAC 40.
NxE1: IDU ES
C1 C2
48xE1 (98,3 /c).
1, 2
481.
1 , C2
, 96xE1
(2x 98,3 /c).
NxDS1: DAC ES
C1 C2
64xDS1 (98,8 /c).
C1 C2
112DS12.
, ,
DAC ES, C1 C2,
56xDS1 56xDS1 .
1 , C2
,
100DS1 RAC 30, RAC 3x RAC 40.
NxDS1: IDU ES
C1 C2
65xDS1 (100,3 /c).
C1 C2
127xDS1 (64xDS1 + 63xDS1).
DAC ES 112 .
IV-7-57
7.
1 , C2
,
127xDS1 (196 /c).
()
(RAC/),
,
NxE1 ( NxDS1) PDH-
.
Mixed ()
LAN/ , LAN P1-C1
1. ,
1, 2 3 C2.
. , ,
Ethernet,
RSTP .
IV-7-58
Eclipse
. 7-16.
, Eclipse
.
,
RSTP.
VLAN -
. VLAN 1 , ,
1
. 2, 3 4 C2
VLAN- (VLAN- 2, 3 4) VLAN
,
.
.
. 7-17. VLAN
.
. /
Port Up Resolved.
5.2 Name ():
. - Auto,
IV-7-59
7.
(10 100Base-T)
.
,
,
:
100%,
.
,
.
, ,
.
,
.
/.
.
,
, ,
.
,
,
.
, 10 .
10 10
.
10/100
, 10/100
RJ-45
.
, AUI (
),
Ethernet-, 10
.
5,4 Mdi/MdiX:
IV-7-60
Eclipse
Auto,
Mdi MdiX ( - ).
,
,
.
5.5 Priority (): .
8:4:2:1,
8 . 10,
Priority Mapping
.
5.6 Port Up:
Ethernet .
.
.
Ethernet-
. ,
Duplex-Speed /
Mdi/MdiX,
.
, , ,
Port Up
. , .
, ,
,
DAC ES.
6. Maximum Frame Size ( )
,
,
()3.
1500 ,
1518 . VLAN,
, 1522. - 1522
IV-7-61
7.
; - 1536 .
7. Enable Flow Control ( ):
.
IEEE 802.3x,
, ,
.
,
,
, .
,
, , ,
, DAC ES / IDU ES
,
.
8. Address Learning: Address Learning ( )
Ethernet-
. Address Learning
,
Ethernet- RSTP-.
,
DAC ES, RSTP-
, DAC ES
. ,
Ethernet Ethernet-
, DAC ES
/ ,
/
, 5 .
9. (, )
DATA System Summary, Rename .
unnamed.
10. Priority Mapping ( ):
Priority Mapping, .
Port Default. Priority Mode (
), .
. . . 7-18.
. - /
MTU, ,
.
IV-7-62
Eclipse
1
2
Priority Mode ( ).
.
Priority Table ( ).
, 8
802.1 63 DiffServ 4 ,
DAC ES: high (),
medium high ( ), medium low ( )
low ().
-
802.1.
,
Internal priority.
Set Defaults ( )
.
IV-7-63
7.
Priority Mode
Port Default
- VLAN 802.1p
DiffServ IP .
Priority
Configuration. . 5.5.
, 8:4:2:1, ,
,
: 2--1, 4--1 8--1 ,
, .
,
,
,
.
802.1p ,
VLAN 802.1p.
(2- ) . . . 7-7.
,
Port Default.
DiffServ ,
Type of Service DiffServ IP.
63 (2-
) . . . 7-7.
, Port Default
.
802.1p-then-DiffServ (802.1p--DiffServ)
, VLAN 802.1p,
Type of Service DiffServ. ,
Port Default .
DiffServ-then-802.1p (DiffServ--802.1p)
, Type of Service
DiffServ IP, VLAN 802.1p.
, Port Default
.
. 7-7.
IV-7-64
VLAN 802.1p
DiffServ
Port Default
6, 7
48 - 63
4, 5
32 - 47
Eclipse
VLAN 802.1p
DiffServ
Port Default
2, 3
16 - 31
0, 1
0 - 15
,
Internal priority.
, Set Defaults ( ).
11. , Send ().
IV-7-65
7.
DAC GE
DAC GE Gigabit Ethernet
RJ-45 10/100/1000Base-T SFP (
-) ,
1000Base-LX ( LC).
DAC GE :
(), VLAN
NxE1, NxDS1 NxSTM1/OC3
(Layer 2) (802.3ad)
(Layer 1)
RWPRTM RSTP (802.1d);
VLAN
QoS
DAC GE, Eclipse
Ethernet :
204.8 /c, 100xE1
196 /c, 127xDS1
310 /c, 2STM1/OC3
DAC GE DAC ES IDU ES,
NxE1 NxDS1.
RSTP RSTP
.
. 7-88.
DAC GE
. 7-19 Plug-ins DAC GE,
Link Aggregation ( ),
Transport Channel Encoding ( ) RWPR
IV-7-66
Eclipse
DAC ES.
DAC GE , E1, DS1
STM1/OC3; Ethernet- E1, DS1 STM1-
.
E1 DS1, RAC
() DAC 155oM ( ).
STM1, RAC.
. 7-19. Plug-ins DAC GE
3
4
IV-7-67
7.
IV-7-68
Eclipse
, (
).
.
64 9600 .
DAC GE
. 7-19 ,
/ ,
,
Ethernet.
IV-7-69
7.
Priority Mapping
( ) VLAN Tagging ( VLAN).
DAC GE,
:
1. Plug-ins .
2. Capacity Type ( ). DAC GE
E1, DS1 STM1/OC3.
Capacity Type ,
. Configuration > Circuits,
Bus Configuration
( ).
3. Channel C1 ( 1) Channel C2 (
2): .
NxE1,
NxDS1, NxSTM1,
:
100E1 1xE1 (1x 2.048 /)
127E1 1xDS1 (1x 1.544 /)
2xSTM1 1STM1 (1x 155 /c)
.4
/c
.
101
16DS, RAC .
RAC 75xE1,
DS1, 128DS1.
IV-7-70
Eclipse
100xDS1 2xSTM1
- RAC 30, - 30
- RAC 3 40
56
- RAC 40 CCDP.
28/30 .
1 DS1 DAC 155oM (
DAC ES),
63xE1 84xDS1.
/ RAC
, Plug-ins
DAC GE.
IV-7-71
7.
IV-7-72
Eclipse
DAC GE Harris Stratex Networks.
Mixed ()
LAN/ , LAN P1-C1
1.
,
2, 4 3 C2.
. Mixed Mode, ,
Ethernet,
RSTP.
. 7-24.
IV-7-73
7.
VLAN -
. VLAN 1 , ,
1
C1. 2, 3 4, LAN
" LAN" (VLAN)
2. VLAN
P2 P4 .
C1 C2
.
. 7-25. VLAN
5.
:
No Failure Detection (ES Compatibility) (
(ES-)) , DAC GE DAC
ES IDU ES.
(RFD), RWPR RSTP
(layer 2).
Rapid Failure Detection RWPR RSTP
. ,
DAC GE
Rapid Transport Channel Failure Detection (
). (DAC GE
3,4 3,5).
IV-7-74
Eclipse
.
. /
Port Up Resolved.
().
6,3 Duplex - Speed ( - ).
.
1 3; 4 1000
. 1 3, - Auto,
(10, 100 1000Base-T)
.
,
,
:
100%,
.
,
.
IV-7-75
7.
, ,
.
,
.
/.
.
,
, ,
.
,
,
.
, 10 .
10 10
.
10/100
, 10/100
RJ-45
.
, AUI (
),
Ethernet-, 10
.
6,4 Mdi/MdiX:
.
Auto,
Mdi MdiX ( - ).
,
,
.
IV-7-76
Eclipse
,
.
.
12, Priority Mapping,
.
6,6 Port Up:
Ethernet .
.
.
Ethernet-
, ,
, / Mdi/MdiX.
, ,
, Port Up
. , .
,
, ,
DAC GE/ES.
(MTU),
,
(). MTU ,
, 5.
: 64 9600 .
DAC ES / IDU ES ,
- 1536 .
MTU, Harris Stratex
Networks: DAC GE.
. - /
MTU, ,
.
IV-7-77
7.
IEEE 802.3x,
, ,
.
,
,
,
.
, (flow control)
,
, , DAC GE
(flow control).
9. Disable Address Learning ( ): Address
Learning ( )
Ethernet-
. Address Learning
, Ethernet-
RSTP-.
,
DAC GE, RSTP ,
DAC GE .
, Ethernet
Ethernet-
, DAC GE
/ ,
/
, 5 .
10. RWPR Port Settings ( RWPR):
RWPR Setting ( RWPR).
DAC GE
RWPR (RSTP), :
RSTP /.
(
DAC GE RSTP).
( /
) / .
IV-7-78
Eclipse
. 7-27. RWPR
IV-7-79
7.
. DAC
GE 100, DAC GE
DAC GE ( ) -
100, DAC GE 200.
10.5 RWPR Priority ( RWPR) /
, ,
/ ,
DAC GE ( ).
: 0 255.
(Port ID),
.
RWPR ,
RSTP ,
, .
,
.
, RSTP
/
.
RWPR Cost ( /) RWPR Priority (
/) ,
.
,
( / ),
.
,
Ethernet Ethernet-,
, Cost Priority
,
DAC GE ( ) DAC GE,
, RSTP
DAC GE ( ) , -
. RWPR Cost
(, 500) DAC GE. RWPR Priority
(, 50).
, (
) DAC GE.
.
-
, DAC GE ( )
.
. 7-28 .
IV-7-80
Eclipse
DAC GE
300
C2
P1
C1
200
C2
150 /c
= 100
= 500
= 100
= 500
P1
= 50
= 300
= 50
= 300
150 /c
150 /c
= 50
= 300
= 50
= 300
C1
C1
= 50
= 300
= 50
= 300
150 /c
C2
P1
100
DAC GE
C1
C2
P1
10
DAC GE
IV-7-81
7.
1
2
Priority Mode ( ).
.
Priority Table ( ).
, 8
802.1 63 DiffServ 4 ,
DAC ES: high (),
medium high ( ), medium low ( )
low ().
-
802.1.
,
Internal priority.
IV-7-82
Eclipse
Set Defaults ( )
.
Priority Mode ( ),
.
.
Port Default
- VLAN 802.1p
DiffServ.
Priority Configuration >
Basic Setting. . 6,5.
802.1p ,
VLAN 802.1p. DAC GE
(2- ) . . 7-8
.
DiffServ ,
Type of Service DiffServ IP. DAC GE
63
(2- ) . . 7-8
.
No Priority ( ), DAC GE
;
.
-
.
VLAN ,
, .
VLAN
,
,
VLAN ,
,
Configuration DAC GE.
IV-7-83
7.
. 7-8. DAC GE
DAC GE
802.1p
DiffServ
6, 7
48 - 63
4, 5
32 - 47
2, 3
16 - 31
0, 1
0 - 15
,
Internal priority.
, Set Defaults ( ).
13. VLAN Tagging ( VLAN): VLAN
Tagging, .
DAC GE 802.1p
VLAN
.
; . 7-30 . 7-31.
,
, (
).
.
,
DAC GE (
).
VLAN
Harris Stratex Networks: DAC GE.
ID LAN ( 0 4095)
. VLAN ID (
ID).
IV-7-84
Eclipse
DAC GE ,
LAN- ,
/. DAC GE,
, VLAN
VLAN,
DAC GE, .
VLAN ,
LAN VLAN
. , LAN ( 1 4)
LAN (VLAN)
/ Eclipse; Eclipse
, .
LAN (VLAN) ,
,
802.1p
802.1.
,
VLAN.
. 7-30. VLAN DAC GE
IV-7-85
7.
VLAN. .
.
VLAN ID ( 0 4095)
1. VLAN ID .
Priority () 1. 8-
. VLAN VLAN.
, VLAN
VLAN
.
VLAN.
.
1.
IV-7-86
Eclipse
IV-7-87
7.
,
.
- .
.
,
:
, ,
QoS,
,
.
,
,
.
DAC GE :
(layer 1) (layer 2).
(L2) MAC-
/ MAC/LLC
Ethernet.
LAN ,
MAC- .
(L1)
;
. ,
MAC-
, ,
, ,
.
(RFD) RWPR,
,
50 .
, (
) (CCDP),
RAC 40.
,
, L1,
( )
.
L2.
IV-7-88
Eclipse
(layer 2)
, ,
, MAC-
, ' ' ('aggregation
key), ,
7. IP,
LAN- .
MAC- -
, ,
L2 . -
.
MAC-
( 15),
,
.
LAN (20+ ),
, ,
.
,
. ,
.
,
.
. 7-32 300 / LAN-
150 /c.
,
.
, ,
.
Plug-ins.
L2, MAC-
. , ,
-
.
IV-7-89
7.
/: 150 /
Eclipse
DAC GE
DAC GE
300
/c
Eclipse
150
P1
/c
C1
P1
C1
P2
P2
P3
P3
C2
C2
P4
150
300
P4
/c
150 /
Eclipse
DAC GE
Eclipse
DAC GE
P1
150
Eclipse
DAC GE
Eclipse
DAC GE
/c
C1
C1
P2
P3
P3
P4
P1
VLAN 10
VLAN 20
VLAN 30
P1
P2
C2
C2
150
/c
150
/c
C1
C1
P4
P1
P2
P2
P3
P3
P4
C2
C2
150
/c
P4
VLAN 10
VLAN 20
VLAN 30
(layer 1)
(L1),
DAC GE ,
, -
( Portal Circuits).
DAC GE, NxE1, NxDS1
NxSTM1-,
.
IV-7-90
Eclipse
.
,
: 1 8 , 9 20 - .
Ethernet
( ), ,
Ethernet .
L2,
,
. ,
, ,
,
.
,
.
. 7-34. (L1) 300 /:
STM1- 150 /
INU
DAC GE
P1
1 1 DAC GE
1 1
1
150 /c
C1
300 Mbps
RAC
P2
P3
P4
150 /c
C2
2 1 DAC GE
1 2
Backplane
bus
RAC
2
. 7-34 (L1).
300 /c C1 DAC GE
150 /c, ( )
, RAC 40 XPIC
CCDP.
(L1) E1, DS1 STM1/
OC3 3,6 .
Rapid Failure Detection and Protection (
) Transport Channel Mode (
) DAC GE.
IV-7-91
7.
AUX
AUX Eclipse.
Eclipse :
.
64 /c, 19,2 /c.
/ TTL
Form C.
AUX
AUX . 3-84, II, 3.
Eclipse :
,
64 /c, 19,2 /c.
/
TTL Form C.
/
.
:
NMS
AUX
/ .
Eclipse AUX NMS,
AUX , Eclipse.
NMS
,
Data () NMS:
Data
Eclipse.
NMS NMS Eclipse
Eclipse. Eclipse.
:
Data
IV-7-92
Eclipse
NMS
Data
V.24/RS-232
V.11/RS-422 -
()
(RAC DAC 155oM)8.
- NMS.
,
RA DAC 155oM. ( AUX
).
,
AUX.
. 7-35.
AUX AUX . 7-97.
AUX . 9-18.
,
,
.
AUX ,
. 7-35 . 7-94.
6 512 /c. .
. 7-95.
IV-7-93
7.
. 7-35. AUX
AUX Plug-in
>
()*
Circuits > Auxiliary Screen
:
:
* AUX
-
LINK-LINK, LINK-DATA DATA/DATA
( 1 6, 1 6)
,
LINK DATA AUX
NMS
NMS
V.11/RS-422, 64 /.
INUe, AUX 1 6,
NMS .
NMS , AUX
IV-7-94
Eclipse
7 9.
NMS Eclipse (IDU 100
IDU 300-).
NMS Eclipse,
(,
ATPC) .
64 /c (
INU/INUe, IDU) . 64 /
c "/".
, NMS
.
RAC () DAC 155oM
( ) ( ,
) IDU.
512 /c,
:
RAC 10/ODU 100, IDU 100-9 192 /c.
DAC 155oM NMS: RSOH
( ) MSOH ( ). RSOH
192 /c. MSOH 512 /c.
4DS1, QPSK, 256 /.
,
INU/INUe, :
NMS Eclipse 128 /c.
64 /c (
128 /c)
.
512 /c, , , 64
/c
NMS 128 /c (512 128 /c).
IV-7-95
7.
10
11
IV-7-96
Eclipse
AUX
. 7-36 .
. 7-36. Plug-ins AUX
IV-7-97
7.
Auxiliary Ports ( ):
Commissioned.
, .
Sync ().
Name. /ID ().
. Data () NMS.
NMS IDU Eclipse.
NMS Sync.
. Sync () Async ().
. .
Status (). ,
.
AUX, :
1. Plug-ins .
2. Port,
.
3. Function (): Data () NMS. (NMS
Eclipse)
4. Type (): Async() Sync ().
Function > Data.
NMS, Type Sync.
Async, Async Port Settings.
.
,
19,2 /c.
Sync, Sync Port Settings.
clock source ( ) clock phasing
( ).
5. Description ()
IV-7-98
Eclipse
. 64 /c.
6. Status () ,
.
7. Commissioned (
) :
Sync,
, . ( ,
).
Async, .
8. ()
.
9. Function > Data, Configuration >
Circuits > Auxiliary Circuits,
- . . -
. 9-19.
AUX,
,
AUX (RAC/ DAC 155oM).
IV-7-99
7.
:
Eclipse
Eclipse
2 TTL 4
Form ,
2 TTL 4
Form .
4 TTL 2
Form ,
6 TTL
( )
, .
Active Condition Low , 0 TTL ,
.
Active Condition High
+5 TTL
(> +2), .
.
Active Condition De-energized ,
.
Active Condition Energized ,
.
,
/. . E.
. 3-87, II, 3.
,
;
Alarm Actions. "
Eclipse" . 12-1.
IV-7-100
Eclipse
/ AUX
. 7-37 /
AUX Eclipse. Eclipse,
Alarm I/O.
. 7-37. / AUX
1
2
INU/INUe /.
IDU .
IV-7-101
7.
/
1. Plug-ins .
2. Alarm I/O.
3. Port Layout ( ):
.
.
4. Active Condition ( ):
,
. Active - Low (
) ,
( +5),
. Active - High (
) ,
+5 (> +2).
, (
) .
5. Current Condition ( )
.
,
( )
TTL +5, - ,
. ,
,
( TTL 0),
" ",
.
: / / -
.
,
() ,
.
6. , Send ().
:
Eclipse . 11-1
,
().
/
E.
IV-7-102
8.
.
:
. 8-1
. 8-23
.
:
RAC
RAC
RAC
RAC RAC/DAC 155oM
, , /
.
/ ;
.
.
:
IV-8-1
8.
. 8-1 ;
, -. RAC (RAC 30 RAC 3X)
INUe.
. 8-1.
1+1
Super-PDH Eclipse
1+1.
1+1
, . ,
(SD) /
1+1.
1+1
. RAC 40
,
/
,
.
RAC 40 1+1
. 3-129, II,
3.
DAC.
DAC :
DAC 3xE3/DS3
IV-8-2
Eclipse
DAC 3xE3/DS3M
DAC 1x155o
DAC 2x155o
DAC 2x155e
DAC 155oM
:
. 8-3
. 8-4
Protection . 8-13
:
. 3-92, II, 3.
, , .
. 3-117, II, 3.
G.
RAC ,
, - .
/ RAC,
/ - .
, ,
,
/ .
/ .
: RAC/
RAC, RAC/DAC 155oM DAC 155oM/DAC 155oM. DAC 155oM
.
IV-8-3
8.
DAC ,
, - .
/ Portal
()
RAC DAC 155oM LINK, RING DATA
( , System
Summary Plug-ins) Launch Remote (
).
Eclipse.
1+1 :
. 8-8.
1+1 . 8-9
:
1. - ;
.
RAC
.
RAC RAC DAC
155oM. RAC , , RAC 30
, RAC 10 - .
DAC .
2. RAC (Tx) (Rx)
.
3. Protection RA RAC
LINK. DAC DAC
DATA.
4. -
INU INUe.
Eclipse . 1-7 .
5.
( RAC 40),
.
- RAC 40
INU/INUe.
Eclipse.
IV-8-4
Eclipse
- RAC 40
- INU,
INU , -
. ,
Polarization Settings ( ) Plug-ins.
ODU
.
6. ,
RAC DAC ,
Protection.
7.
Non-Protected () Partners (),
(, DAC 16x),
System Summary.
8. LINK (2xRAC)
,
- ( ) RAC.
DA ( DAC), DATA
- DAC.
, RAC/DAC,
.
,
, , ,
RAC, RAC,
,
Partners.
,
, ,
RAC, . ,
RAC, , .
DAC,
DAC, .
, DAC, ,
.
9.
(2xRAC, RAC DAC 155oM 2xDAC 155oM),
- ( )
RAC DAC.
IV-8-5
8.
,
, , ,
RAC DAC, RAC/DAC,
,
Partners.
RAC / DAC,
, ,
RAC/DAC, . ,
DAC/RAC, , .
10.
.
Standard () Sensitive ().
. 3-92, II, 3.
Error-free Timer ( )
10 , 1, 5 10 .
, ()
.
Delay Ring Unwrap Timer (
)
( ,
).
11. , ,
(On-line LED) RAC ,
, ,
1.
12.
RAC ,
RAC ( RAC
, RAC
TDM-).
13.
, RAC ,
RAC ( RAC
, RAC
TDM-).
IV-8-6
Eclipse
IV-8-7
8.
1. RAC INUe.
RAC " ".
RAC " ".
2. RAC, ,
RAC 30, - RAC 3X.
,
, RAC,
, , RAC,
.
3.
.
4.
. . . 8-1 . 8-2.
,
.
5.
/ .
6.
.
7.
.
8. -
.
( / /
)
.
9. .
() (Rx) ,
-
.
. 3-96, II 3
. 3-124, II, 3.
10. -
(Rx) ,
(Tx) - .
11. -
(Rx):
IV-8-8
Eclipse
(Tx) (
). (
/ / )
(
).
,
,
.
12.
( ),
.
, ,
.
13.
(
),
, .
, , ,
.
1+1
1. 1+1
, . ,
(SD)
/ 1+12.
2. ,
1+1.
Eclipse ( / )
1+1.
3. 1+1
.
RAC 40
,
/ ,
.
, , ,
. ,
1+1 , Portal
.
IV-8-9
8.
, 1+1
, (
).
RAC 40 1+1
. 3-129, II,
3.
4. () :
, 1+1,
.
,
3 BER 10-6.
. 3-125, II, 3.
1+1
(Rx) / (Tx).
. 3-118,
II, 3.
1+1 "
" RAC.
,
, , .
. 3-126, II, 3.
1+1
1+0.
. 3-126, II, 3.
.
. 3-117, II, 3.
Event Browser
()
.
. 8-1 , ,
.
. 8-2 ,
, - 1+0.
1+1
10-6 BER .
IV-8-10
Eclipse
.
,
.
. , ,
,
1+1
.
. 8-1. :
SD+SD
RAC
RAC
RAC
RAC
. 8-2. : SD +
1+0
RAC
RAC
RAC
( ) , ,
, ,
(Tx) (Rx)
,
" ".
"",
(Tx) /
(Rx) .
IV-8-11
8.
" "4 ,
, 5 .
, " " ()
() - ,
.
(Tx), " "
( RAC ).
,
"-",
( ,
1+0).
NMS 1+1 (
, 1+0).
1+1.
1+1
1+1 .
1+1
(On-line LED) RAC :
1+1 (
) (On-line LED) RAC
SD;
, RAC
, RAC (
), (On-line LED) RAC
.
1+1
(On-line LED) RAC .
(On-line LED) RAC ,
1+1 ,
, ,
(
1+0).
" " ,
.
IV-8-12
Eclipse
Protection
Protection :
/ Link
() (RAC) Data () (DAC)
RAC DAC
.
. 8-3 . 8-14 Protection INUe.
. 8-4 . 8-16 Protection .
. 8-5 . 8-18 Protection DATA/
DAC.
:
Protection . 8-18
. 8-19
IV-8-13
8.
Protection
, .
.
IV-8-14
Eclipse
Link 2 ,
(/)
.
, () Link 1.
Protect (), .
, Link 1 /
Link 4.
. LINK/DATA
(RAC c DAC 150oM).
IV-8-15
8.
. 8-4. Protection
IV-8-16
161 (
1xE1/DS1).
,
,
"-".
(wrap)
(standard) (sensitive).
(unwrap)
(standard), (sensitive)
(delayed). , ,
.
10-6 BER .
Eclipse
.
.
IV-8-17
8.
. /
DATA1 DATA2.
Protection
:
RAC ( RAC )
DAC (E1/DS1 Ethernet DAC
)
, /
( , /) LINK
DATA.
, RAC
.
IV-8-18
Eclipse
- E1/DS1, ,
, ,
"-".
Protection :
.
.
.
.
, ,
10-6 BER
DATA/DAC.
.
.
1+1, . .:
. 8-8.
1+1 . 8-9.
XPIC, ,
. 3-129, II, 3.
,
:
1. LINK, DATA LINK/DATA,
.
2. LINK DATA .
, -
-; LINK DATA,
, ,
-
. (
Consequences).
IV-8-19
8.
, ,
Protect Protection Selection (
). -.
LINK ,
.
DATA
, .
3.
, .
LINK, ,
;
.
LINK, ,
Protect Protection Selection ( ).
. ,
.
4. RING , ,
- . LINK DATA (DAC 155oM),
, ,
-
. (
Consequences).
, ,
Protect Protection Selection (
). -.
IV-8-20
Eclipse
(wrap) (unwrap)
. . . 8-4. (Standard)
(Sensitive) ,
(Error-free Timer)
(Delayed Ring Unwrap timer):
-
, .
. 3-124, II,
3.
-
10-6 BER .
/ 10-6 BER.
,
10-6 BER.
- (Error-free Timer)
, ,
. (
, ,
.
,
). 5
( ).
-
(Delay Ring Unwrap)
, , ,
, ,
, , Error-free Timer.
- , (Wrap)
(Unwrap) Standard.
- Delay Ring Unwrap (
) 1 . ,
,
Error-free Timer, Delay Ring Unwrap
.
- System/Controls ,
.
Error-free Timer, Delay Ring Unwrap Timer. (
).
5.
IV-8-21
8.
IV-8-22
Eclipse
:
IDU
IDU 300 8x
IDUsp 16x
,
, 1
IDU 155o
1.
Harris Stratex Networks .
(Rx) (Tx)
, IDU 300 20xV2 IDU 155o,
(Rx) ( )
.
Tributary
Protected ( : ) Tributary Always On
( : ).
:
. 8-23
IDU . 8-27
, IDU 300 20xV2
201 16xDS1,
PSU .
20xE1 / 16xDS1
IDU Y-
.
IV-8-23
8.
IDU, IDU,
40xE1 32xDS1 .
(PSU), RAC/ODU
.
:
1. - IDU
, ,
(Tx).
2. ;
.
3. IDU
INU. IDU IDU5
.
4. IDU
().
5. IDU, ,
(Tx) (Rx), ,
IDU 6.
6. (Tx) (Rx) ,
IDU 155o IDU 300 20xV2, ,
(
), ,
( ), , IDU
. , ,
(Rx), (Tx)
.
7. (Tx) (Rx) ,
IDU 155o IDU 300 20xV2,
(
).
5
, ,
IDU ,
, 8 IDU 300 8x IDU 300 20x.
6 , IDU IDU, 10
IDU, IDU . IDU
, 10 , IDU
IDU.
IV-8-24
Eclipse
8. ,
(Tx) (Rx),
Portal.
9. /
7;
.
,
IDU,
IDU .
(
IDU),
.
10. /
-.
11. IDU
NMS Ethernet,
,
NMS.
12. , IDU
( - ).
, Enable IDU Protection
( IDU) IDU.
13. IDU, 8 NMS,
( -48 . ), NMS
.
IDU
, NMS ,
, NMS - IDU.
14.
. , ,
IDU (Tx), (Rx)
, IDU - .
15. - IDU IP-
(
).
IP- .
.
7
/
NMS.
8 IDU- NMS
NMS.
IV-8-25
8.
OSFP RIP.
, ,
IDU, IDU,
NMS Ethernet , /
, -
IDU.
16. : Tributary
Protection ( ) (TT) Tributary Always On
( ) (TA).
Tributary Protection.
Tributary Protection
Y-.
IDU, IDU .
; .
Tributary Always-On ()
IDU
.
IDU, IDU
( TT).
,
IDU;
.
17. - LOS
. ,
( Plug-ins
commisioned
). ,
, ,
( ). LOS
IDU 300 20xV2,
20xE1 / 16xDS1.
18. , IDU
()
.
19. IDU ,
( )
, ,
CompactFlash.
20.
.
. 3-117, II, 3.
IV-8-26
Eclipse
IDU
IDU:
, - IDU
Ethernet.
, IDU .
, IDU
.
,
IDU. IDU 300 20xV2,
, 20xE1 16xDS1,
.
" ".
IDU
. 3-8, IV.
IDU Portal,
IP- ( V.24
Ethernet DHCP, IDU).
Portal IDU,
NMS Ethernet IDU.
:
1. Information () - .
2. Plug-ins () - , ,
, / .
- IDU .
( ).
3. Networking ( ) - IP- .
- IDU IP-.
( )
, .
OSPF- RIP-.
,
, . .
, 15.
IV-8-27
8.
9
10
IDU ,
" ".
IDU , IDU, -
, . Portal
/
IDU.
IV-8-28
Eclipse
IDU.
.
:
IDU . 2-36, II, 2.
/ ,
System/Controls . 15-45,
IV, 16.
.
IDU ,
IDU.
IV-8-29
8.
IV-8-30
Portal ,
File > New Portal > IDU Partner.
9.
Circuits
:
.
LINK (RAC, DAC
155oM, IDU), NMS.
.
,
, .
INU/INUe Eclipse IDU ES.
- IDU ES
Ethernet-, E1/DS1 AUX
INU/INUe, 1xRAC, 1xDAC ES, 1xDAC 16x
1xAUX.
:
- . 9-2
- . 9-18
IV-9-1
9.
-
-
. :
E1, E3, DS1, DS3 STM1/OC3.
, Eclipse E1-, E3-, DS1-,
DS3- STM1/OC3-.
, , 1 STM1,
DAC 155oM STM1/OC3
NxE1 DS1, E1
DS1.
DAC 3xE3/DS3M E13
M13 3 DS3,
E1/DS1.
13 3-;
161.
M13 DS3-;
16DS1.
Ethernet- E1, DS1 STM1/OC3.
,
RAC;
LINK.
Circuits :
,
.
, ,
- "drop-insert"
(-) "pass-through" ().
:
- . 9-3
- . 9-5
- . 9-6
- DAC ES/GE . 9-7
- . . 9-9
- - . 9-12.
IV-9-2
Eclipse
-
. 9-1 Circuits ,
311,
161, DAC 16xE1 (DAC 16x):
Eclipse
32xE1
16xE1
16xE1
9-1. Circuits
1
2
3
7
(Traffic) (Auxiliary).
( 5).
IV-9-3
9.
-
. -
- .
,
.
IV-9-4
.
NxE1, NxE3, NxDS1, NxDS3
NxSTM1/OC.
()
. 32
1001 .
Eclipse
-
. 9-2 -
,
Link 1 Link 3 :
9-2. Circuits,
Eclipse
64xE1
32xE1
Ethernet
16xE1
16xE1
1
Use scroll bar to
view all circuits
2
3
4
, .
,
.
IV-9-5
9.
/ .
- E1.
-
. 9-3
, . 9-2.
- - . 9-12
.
9-3.
IV-9-6
, From ().
To (),
.
Eclipse
,
From (); To
(); Apply (),
.
( ),
.
()
"",
.
From To,
.
, . -
.
( )
.
.
- DAC ES/GE
DAC GE, E1 DS1,
Circuits DAC ES.
DAC GE, STM1,
, STM1.
. 9-4 - DAC ES ,
. 9-2.
DAC ES/GE, . DAC ES
DAC GE . 9-16.
Ethernet IDU ES , DAC ES.
IV-9-7
9.
9-4. - DAC ES
IV-9-8
DAC ES.
321 Link 1, Ethernet- 65
/c.
1 1 DAC ES (1 2).
(1) DAC ES.
(1) Link 1.
Eclipse
- .
. 9-5 . 9-10
"-". DAC 155oM
RAC 30.
:
RAC 30 321 (
Plug-ins).
DAC 155oM 631 (
DAC 155oM).
,
321 (
).
,
, 221. 411
101 -
.
DAC 16x 41 / (drop-insert)
, , 181 /
(pass-through) .
DAC ES 81 (16 /c) LAN
" "; 8xE1 "-"
81 - .
"-"
331 21 - .
Circuits . 9-6 . 9-11.
IV-9-9
9.
9-5. -
Eclipse
EAST
DAC 155oM
63xE1
WEST
22xE1 1-22
(18 & 4 /)
RAC 30
32xE1
22xE1
22xE1
8xE1
8xE1
33xE1
2xE1
2xE1. -
East (31-32)
33xE1 . -
West (31-63)
8xE1 -
23-30 East
4xE1 ./.
12-15
Rx
C2
Tx
DAC 16x
P4
C1
P1
8xE1 -
23-30 West
DAC ES
Ethernet-
4xE1
.
LAN
/ ,
, , .
, A.
IV-9-10
Eclipse
3
4
5
321 (321
RAC, 631 DAC 155oM).
, 221.
/.
101
"-" RAC, 411 DAC 155oM.
( , ,
point-to-point (-)).
IV-9-11
9.
- -
-,
. "-"
. 9-15, "
", A.
DAC ES DAC GE, .
DAC ES DAC GE . 9-16.
DAC 3xE3/DS3M, .
DAC 3xE3/DS3M . 9-17.
,
:
1. Traffic Circuits Configuration > Circuits.
2. . Bus Configuration
.
E1, DS1, E3, DS3 STM1/
OC3. ,
, Plug-ins RAC/
DAC. ,
( ) Plug-ins Circuits.
.
- ( Eclipse )
- DAC ES,
NxE1 NxDS1.
3. ,
LINK,
RING DAC,
( )
(port-to-port connections). . . 9-1.
/
(unallocated).
,
.
4. , From To
circuits unallocated ( )
port-to-port connections.
Port-to-port connections
IV-9-12
Eclipse
() . . . 9-3.
From, ,
, Select a module to view
circuit connections ( ).
From > Port ( )
, .
To, -
( ,
To).
To > Port ( )
.
, From To
,
.
, From 321,
To - DAC 16xE1, From To
161. ,
-,
Port, .
5. Apply ().
port-to-port
connections, , ,
.
Apply
.
,
.
,
From To,
, Apply.
Apply .
6. ,
Port-to-port
connections.
( ),
, ,
, - , . .
. 9-2 . 9-5. -
IV-9-13
9.
, .
,
, .
,
BER- DAC,
.
7. ,
Port-to-port
connections.
. ,
.
From To .
, ,
.
, , - .
Port
Circuit. , ,
Apply (). . 9-7.
.
.
,
Circuits Unallocated
( ),
.
IV-9-14
Eclipse
9-7.
2
3
From To
.
To From
. , Ring
1, Port1 DATA 2 Port 5, To: Port
5, Apply. DATA 2 Port 1
.
. ,
.
Port .
8. ,
( ) (
) disconnect ().
9. , Send
().
"-"
1. (Backplane Configuration)
IV-9-15
9.
E1 DS1.
NxE1 NxDS1.
2. RING
. , ( - ),
pass-through circuits ( ).
3. .
, A.
DAC ES DAC GE
DAC ES, DAC GE,
1 DS1.
1. 1 DS1, Ethernet-
NxE1 NxDS1.
2. 1 DS1 Channel C1 ( 1) /
Channel C2 ( 2)
, ..
DAC ES,
..;
.
3.
.
, C1 DAC ES 201, DAC ES/GE
( ) 1
201.
, , 20
1 20, - 11 30.
4. DAC ES DAC GE
Link (RAC DAC 155oM) .
1 DS1, Ethernet-,
DAC 1 DS1.
, E1/
DS1 DAC ES/GE - ,
E1/DS1,
DAC ES/GE1.
5. DAC ES Ethernet-
961 120DS1 ( );
Ethernet- E1
DS1 TDM- , 1001 128DS1.
6. DAC GE 1001
1
IV-9-16
Eclipse
127DS1 ;
Ethernet- 1 DS1 TDM-
, 1001 128xDS1.
7. DAC ES,
- DAC GE.
8. " " DA
ES/GE Mixed ().
1 1
C2 ,
.
DAC 3xE3/DS3M
1. 3xE3/DS3
3 DS3. , DAC 3xE3/
DS3.
2. E13/M13 1
DS1.
3. E13/M13 E3 DS3
:
E3 , Tx/Rx 1, 1 1 16
E3 , Tx/Rx 2, 1 17 32
DS3 , Tx/Rx 1, DS1 1 28
DS3 , Tx/Rx 2, DS1 29 56
4. E13/M13, 1/DS1
Eclipse,
1 DS1 , ,
16xE1 28xDS1 .
5. E13/M13
3 DS3 (
13/M13 DAC 3xE3/DS3M),
1 DS1
c DAC 16x DAC 4x,
INU/INUe / INU/INUe LINK (RAC).
6. E3 Transparent ( 3) 1
171.
IV-9-17
9.
, ,
, (Auxilary)
LINK DATA (DAC 155oM), NMS
.
, - AUX,
,
AUX (RAC/ DAC 155oM).
, Plug-ins AUX
, -.
. - . 9-19
Circuits
. 9-8 - ,
AUX 1 3, DATA, 2,
NMS.
-
Data (). NMS ,
AUX.
9-8. Circuits
1
2
3
4
IV-9-18
Eclipse
Auxilary.
NMS
Plug-ins AUX.
.
Plug-ins AUX. ,
. ,
AUX 3
Link 1, Ciruits Auxilary.
, ;
AUX .
, .
,
:
1. Auxiliary Circuits Configuration > Circuits.
2. ,
.
,
: AUX, LINK (
RAC) DATA (DAC 155oM).
/ AUX
(unallocated).
AUX
, .
port-to-port connections
.
,
.
3. , ,
IV-9-19
9.
, , AUX, 6
, NMS
- 128 /c. , , AUX
1, NMS 448 /c
(512 64).
IV-9-20
10.
Networking
IP- NMS,
DHCP-.
:
. 10-1
Networking . 10-5
DHCP- . 10-17
X4 . 10-23
,
NMS F.
Eclipse
IP- NMS ,
, , ,
Altium, XP4 DXR Harris Stratex Networks
, .
(static routing)
.
,
.
(default gateway).
IV-10-1
10.
(Dynamic routing)
, , RIP (Routing Internet Protocol - ) OSPF (Open Shortest Path First ),
, ,
.
IP- RIP OSPF.
Eclipse
RIP1, RIP2 OSPF. ,
.
, OSFP
OSPF, / OSFP
(OSPF area), OSFP.
Eclipse
.
. Eclipse . 10-2.
Eclipse
,
IP- (single IP addressing) (interface IP
addressing), (static) (dynamic)
. :
1. IP- :
IP- .
Ethernet, (, V.24)
.
.
2. IP-
:
IP- ( ).
NOC (
), /
, .
.
3. IP- :
IV-10-2
Eclipse
IP- .
Ethernet, (, V.24)
( , ).
OSFP / RIP,
.
NMS, /,
OSFP, Enable OSPF Area
( OSFP) ,
, .
. ,
NMS.
4. () IP-
:
IP- NMS
Eclipse: Ethernet, (), V.24.
,
.
.
.
Eclipse .
, ,
F.
IP-
Ethernet.
/ OSFP / RIP,
, V.24. ( V.24
).
IV-10-3
10.
IP- ,
.
, . ,
IP- OSFP,
SNMP
OSPF , IP-
.
()
,
IP-, , .
.
OSPF, RIP1, RIP2.
,
, (
IP- 1.0.0.1).
IV-10-4
Eclipse
Networking
Networking IP-,
.
DHCP- c XP4.
:
IP-
. 10-8
IP-
. 10-8
IP- . 10-13
. 10-15
DHCP- XP4
:
DHCP- . 10-17.
X4 . 10-23
Networking IP-,
:
IP-
- OSPF, RIP1 RIP2.
DHCP-.
XP4.
Interface Addressing (
), Static Routing ( ) Trap Destination
( ).
OSPF-
Enable OSPF Area ( OSPF). NMS,
/, OSPF,
.
.
. 10-1 IP Addressing.
IP- ,
IV-10-5
10.
; , .
:
. 10-2 . 10-10 - Static Routing.
. 10-3 . 10-13 - Interface Addressing.
10-1. IP-
1
2
3
5
6
7
8
IV-10-6
" IP-".
IP- .
, " "
( ).
, ,
OSPF RIP.
, DHCP Server
Portal.
Eclipse
, NMS
NMI XP4 (, / Eclipse
XP4).
OSPF
OSPF.
IV-10-7
10.
IP-
1. IP- (IP Address)
(Subnet mask) Eclipse.
Ethernet Eclipse;
Ethernet.
2. : OSPF, RIP1 RIP2.
RIP1 RIP2, IP-
NMS 15; ( ),
Eclipse - 15.
OSPF.
OSPF, NMS,
/, OSFP,
Enable OSPF Area ( OSFP) ;
, ,
. ,
Enable OSPF Area (
0.0.0.0).
IP-
IP- , ,
, ()
Ethernet. . . 10-2 . 10-10.
Eclipse , ,
( ),
/ , , .
NMS Ethernet (
V.24), IP- , ,
Next Hop ( ).
,
Harris Stratex
. Next Hop , -
(Link).
(default gateway)
Eclipse
/
IV-10-8
Eclipse
NOC LAN1:
NOC
/.
NOC
- /
/,
.
/ ,
NOC (, ), NMS
(ProVision / Portal) / NOC LAN
.
NOC LAN (, )
TCP/IP. (
Ethernet, Portal ,
/
). /
.
,
F. .
NOC. NOC,
,
NOC.
IV-10-9
10.
1
2
3
5
6
(Static Routing).
(destination),
(mask), (interface) (next
hop).
( - ),
.
, (insert),
(remove) (cut)
(copy) .
, .
(
NOC - ,
IP- ,
NOC).
1. IP Addressing IP-
IV-10-10
Eclipse
Eclipse. Ethernet /
, .
Ethernet- Portal
IP- ,
, Send ()
Portal, .
TCP/IP
IP-.
DHCP- ( DHCP-)
Portal. ( Windows DHCP-
).
2. / ,
NMS Eclipse XP4, Enable
XP4 Compatibility ( XP4).
. . X4 . 10-23.
3. Static Routing.
Eclipse.
NMS - ,
.
:
Ethernet Port ( ) - Ethernet
Maint. V.24 ( ) - V.24
Link - . Link
, .
Data - . Data DAC
155oM DAC 3xE3/DS3M 13 13.
4. , Insert ().
IP- (destination) (subnet
mask).
Interface.
.
IV-10-11
10.
5.
:
(
) 2 /
IP- (/
Eclipse, ,
).
,
IP- ,
NOC.
NOC.
NMS Ethernet V.24
, .
V.24 ,
.
V.24 Portal .
Remove () .
Cut () ,
( ).
Copy ()
.
6. , Send ().
,
0.0.0.0 0.0.0.0, .
.
IV-10-12
Eclipse
IP-
Interface Addressing
IP-,
.
IP-
,
.
IP-
.
Ethernet,
(Link) V.24. Eclipse
Link
( ,
).
, Link RING 1:RAC 1 NMS
RING 2:RAC 2 NMS.
. 10-3 IP addressing Eclipse.
10-3.
1
2
3
4
IV-10-13
10.
Interface Addressing ( ).
IP-,
, OSPF RIP. V.24
( ).
, NMS NMI
XP4.
OSPF,
OSPF.
Ethernet, (Link) V.24.
IP-,
Ethernet , .
V.24 IP-
1.0.0.1 255.255.255.255 .
. NMS
( ),
NMS
.
IP-, ,
, IP- 0.0.0.0
255.255.255.255,
/ Ethernet.
IP- F.
(, )
IP-, ,
( ).
, RIP
OSPF.
IP- . 10-8.
,
IP-
. 10-8.
IV-10-14
Eclipse
NMS NMI-
XP4, Enable XP4 Compatibility
( XP4).
.
Trap Destinations
, Eclipse
. ,
ProVision Third Party ( ):
ProVision Mode ( ProVision)
, ProVision
Eclipse .
Third Party Mode ( ) ,
,
.
. Trap Destinations.
, ,
(), .
10-4. Trap Destinations
1. Add Destination ( ),
.
2. Destination IP Address (IP- )
IV-10-15
10.
.
3. Destination UDP Port (UDP- ),
UDP- . ProVision, 162.
4. Max Traps/Min (
) ,
.
,
. - 10,
- 120, - 1.
5. Operation Mode ( ), Provision Third
Party ( ).
6. Enable Destination ( ).
7. Send .
IV-10-16
Eclipse
DHCP-
IP- DHCP-
(DHCP server) (Dynamic Host Communications Protocol) /
Eclipse.
Eclipse, V.24
, DHCP .
Eclipse, V.24,
DHCP .
DHCP- NMS
Ethernet Portal, Eclipse-
DHCP; DHCP- Eclipse IP-
Portal,
IP-.
DHCP
Portal Portal Eclipse . 2-3,
IV.
:
, DHCP- . 10-17
DHCP- . 10-21
, DHCP-
,
Portal Eclipse . 2-3, IV.
DHCP- Eclipse,
V.24 ,
, IDUsp 4x/16x.
DHCP Eclipse,
V.24.
DHCP- ,
Ethernet IP-
. DHCP, Portal
TCP/IP IP-,
.
IP-, , " " 30 -
, IP-
. , ,
Portal, ,
.
IV-10-17
10.
Portal, ,
" " , ,
IP-. ,
30 ,
IP-,
. Portal
.
IP- ,
DHCP, Send, ,
Portal 30 50 ,
, . (
- , Windows; Windows 98,
2000, XP).
DHCP- ,
Portal IP-, TCP/IP
l; DHCP, IP-,
DHCP .
Eclipse ( IDU),
Eclipse (INU, INUe, IDU)
LAN NMS ( NMS 10/100Base-T ),
DCHP-, ,
NOC ( ).
DHCP-,
, c
Portal LAN NMS,
IP- .
Portal Start-up Eclipse LAN NMS,
,
.
LAN DHCP-, ,
()
( , ).
Eclipse
Networking.
NOC ,
LAN , DHCP-,
IP-. (
LAN DHCP-,
LAN ).
V.24
DHCP- , Portal :
IV-10-18
Eclipse
DHCP-,
.
DHCP-
. 2-24, IV.
IP-, TCP/IP
Portal, IP-
.
DHCP- (
V.24) IP-
,
DHCP- Networking.
1
Portal, 30 50 ,
DHCP-.
DCHP- /,
DHCP- IDU ,
.
DHCP-
/ IP- IDU
DHCP-.
DHCP address range ( DHCP)
( )
.
, :
(First) IP- .
(Last) IP- .
IP- IP-. ,
192.168.2.1.
IP- .
IP- .
IP- , IP-.
IP-
( ).
DHCP- , IP-
IP- (First
Last).
IV-10-19
10.
,
(Advanced ()),
LAN , DHCP
, .
DHCP 192.168.255.0
192.168.255.255, ()
Eclipse.
IV-10-20
Eclipse
DHCP-
DHCP-
.
IP-, ,
, - ,
Portal.
Portal, , ,
LAN NMS Eclipse, ,
. , ,
DHCP3 Portal ,
( 30
).
, LAN NMS
Eclipse, IDU
" " INU/IDU,
, ,
IP-. ,
c Portal, ,
.
,
Portal,
. 253
LAN IP-4, 10
IP- Eclipse,
Portal .
. 10-5 Networking
DHCP-.
IP- ,
LAN
DHCP- Eclipse.
.
- Ethernet-
LAN TCP/IP Portal, ,
.
4 IP- 253 ; 255 2.
IV-10-21
10.
10-5. DHCP-
:
1. Enable DHCP server ( DHCP-)
.
,
; , .
2. , , IP address range (
IP-).
IP- LAN (IP- ). ,
LAN DHCP-
Eclipse.
.
LAN Eclipse,
DHCP-, ,
LAN
.
IV-10-22
Eclipse
:
IP- Ethernet Eclipse: 192.168.0.1 (255.255.255.0)
First (): 192.168.0.2
Last (): 192.168.0.10
IP- Ethernet Eclipse: 10.16.11.1 (255.255.0.0)
First (): 10.16.11.2
Last (): 10.16.11.11
IDU (
DHCP-):
IP- Ethernet Eclipse IDU 1: 192.168.0.1 (255.255.255.0)
First (): 192.168.0.3
Last (): 192.168.0.10
IP- Ethernet Eclipse IDU2: 192.168.0.2 (255.255.255.0)
First (): 192.168.0.11
Last (): 192.168.0.20
3. Send .
X4
IP Addressing Enable XP4 Compatibility
(Reduced MTU) ( XP4 ( MTU)).
, NMS- Eclipse
XP4. /
Eclipse
() XP4
XP4 (Enable XP4 Compatibility).
XP4 (
MTU) NMS Eclipse,
NMI- XP4, .
IV-10-23
10.
Ethernet-
Portal / Eclipse,
.
Eclipse XP4,
, ,
XP4 XP4/
Eclipse ( LAN XP4 Eclipse).
Harris Stratex
Networks.
Eclipse, XP4,
: IDU / INU.
NMI XP4
NMS:
6 /c,
NMS Eclipse,
"" NMS-.
IP- (MTU) 600 .
NMI; ,
XP4.
Eclipse , XP4,
- NMS.
Eclipse XP4
XP4 161.
XP4 5
Eclipse.
Eclipse OSPF RIP.
/ XP4
((Eclipse-XP4-Eclipse).
Eclipse NMI XP4
Portal ProVision .
,
5 . Eclipse .
Portal Eclipse
XP4. ,
, :
Portal auto-version .
, 1
.
IV-10-24
Eclipse
IV-10-25
11.
Eclipse
Alarm Actions
AUX:
TTL- AUX
AUX Eclipse.
AUX Eclipse.
, IP-,
AUX .
. Alarm Actions.
Alarm Actions
. 11-1 Alarm Actions.
:
AUX,
.
/ .
/
.
IV-11-1
11. Eclipse
()
/ .
/ /
, /
.
11-1. Alarm Actions
IV-11-2
, .
/
. ,
.
Add, .
IP- / ,
AUX ( )
.
Eclipse
/
/ , AUX
. . /
. 7-99.
, AUX
, / .
1. ,
Configuration > Alarm Actions. . . 11-1 . 11-2.
2. Alarm Action
Destinations ( ), Add
(). 30 .
3. Destination Address IP- /
. IP- Alarm
Actions Destination.
/ /
( /,
/ ), IP-,
/,
IP- : 127.0.0.1.
( IP-),
AUX ,
Alarm Action Destination.
4. Slot AUX
. Alarm Actions Destination.
Eclipse,
; ( 1 9),
Eclipse, /
AUX .
, 1
AUX .
5. Output () AUX
. Alarm Actions Destination.
6. /
.
IV-11-3
11. Eclipse
(
)
.
() AUX.
.
.
/ .
() Alarm Actions
Destination.
7. , Send ().
IV-11-4
12.
Date/Time, . 12-1
:
.
.
/ Portal (Synchronize With
Computer).
NTP ( ).
. . 12-1.
12-1. Date/Time
2
3
4
5
IV-12-1
12.
, Time Server ( )
.
,
/.
Portal,
/.
NTP,
.
Radio Date/Time .
No Change to Date/Time ( /)
.
Enter New Date/Time ( /)
, GMT.
Date/
Time Find Time Zone ( )
. . . 12-2.
/. ,
Send ().
IV-12-2
Eclipse
12-2. /
1
2
,
/.
IV-12-3
12.
, /
30 ,
1 33 .
NMS / .
, /
30 ,
.
,
5 ,
.
NTP-, /
,
. ;
,
( )
.
NMS
.
NTP- .
NTP-
pool.ntp.org time.apple.com.
IV-12-4
Eclipse
12-3. NTP-
,
.
/ (NMS)
.
IP-.
Synchronize Now
/ ;
/
.
IV-12-5
12.
IV-12-6
13.
,
. .
:
Software Management
Eclipse .
Eclipse
,
.
, .
, 3.1.65, '3' - , '1' - , '65' -
.
:
.
IV-13-1
13.
:
.
: /
.
, , .
, ,
/ Eclipse
.
Harris Stratex .
Software Management
Software Management ,
.
. 13-3, Software Management . 13-1 . 13-7.
Eclipse NCC () ODU.
-
.
Eclipse IDU ODU,
.
Load Status ( )
.
ODU
RAC.
. Transfer-only
( ) Activate-only ( )
,
, ,
.
IV-13-2
Eclipse
/,
Start ().
/:
/ Portal .
IV-13-3
13.
Start:
1. Software State ( )
"Transferring software" ( ),
.
,
.
RAC ODU 100 ODU 300, ODU
,
,
,
ODU.
2. Progress 0% , ,
100%.
.
, , ,
NCC/IDU , ODU ( 20 ).
, NCC/IDU
, , Ethernet,
. ODU
( NCC/IDU), 38,4
/c "".
, ,
Active Version ( ),
Software OK ( ) Software Status (
).
IV-13-4
Eclipse
, Portal
. 2005
Portal .
7. /
System Summary.
Start:
1 2 Load and Activate (
),
"Software (version) transferred, awaiting
activation" ( () ,
) Software State.
Start:
4 5 Load and Activate (
), Portal
6 7.
IV-13-5
13.
Advanced (),
.
.
Eclipse CompactFlash .
() .
()
, ,
.
,
, Transfer Only ( ) ,
.
. - ,
Transfer Only.
, , ,
. .
, Software State , .
, ,
, .
IV-13-6
Eclipse
1
2
3
4
Software Status ( )
.
.
IV-13-7
13.
IV-13-8
/ .
Select () ,
.
,
Advanced ().
, /
, .
14.
Security
.
: Security.
Security
, Portal
Start-up ,
, .
. 14-1.
14-1.
admin
()
port_adm
.
/, .
Eclipse .
engineer
()
port_eng
/.
Eclipse ,
.
operator
()
port_op
.
Eclipse ,
.
IV-14-1
14.
. 14-1 Security
.
14-1. Security
1
Security () Configuration.
,
Activate security ( ),
.
Login . Login
(), Send (),
.
/
.
- port_adm.
Reset Passwords ( )
.
. 14-2 Eclipse
. ,
, Configuration
IV-14-2
Eclipse
Security
.
Security Account
( ) ,
.
Reset Passwords ( )
.
,
, ,
, ,
.
, ,
. 2-30
.
IV-14-3
15.
Portal
Eclipse,
.
Portal Diagnostic :
System Summary
Event Browser
Alarms
History
Performance
System/Controls
Circuit Loopbacks Eclipse
Parts
Advanced Management
IV-15-1
15.
System Summary
System Summary Portal, .
Eclipse, ,
.
. System Summary . 15-3.
. : . 15-6.
. 15-1 Eclipse.
15-1. System Summary Eclipse.
6
7
8
IV-15-2
System Functions , ,
.
RAC DAC .
Eclipse
Eclipse
.
, .
.
Replaceable Units
.
IP-, .
/,
.
Screen Options ,
.
Circuits,
. ,
.
System Summary
/
( ) .
System Summary ,
Layout. Layout .
System Functions ( )
/
. , ,
, Eclipse
, ,
Alarms. ,
,
, ,
.
Eclipse, :
IV-15-3
15.
, .
: . 15-6.
(RAC) .
RAC DAC. -
,
.
.
DAC.
Eclipse, 1:
.
.
.
.
, .
. /
Event
Browser . 15-10.
.
.
Portal . 1-3.
. ,
.
.
, ,
Launch Remote, LINKS (RAC DAC
155oM).
IV-15-4
Eclipse
Circuits, Circuit
Loopbacks.
System Summary () ,
<Back .
, , Plug-ins,
.
:
,
.
,
,
. ( ).
, .
Replaceable Units INU/INUe (
).
Replaceable Units
Replaceable Units Eclipse.
. .
,
System Functions.
,
System Function.
( Portal)
/ .
IV-15-5
15.
.
.
- ,
, .
System Summary, -
,
System Summary.
,
, Rename () .
unnamed.
Portal,
. : Plug-ins, Protection, Circuits, Networking, System
Summary, System/Controls, History.
:
:
Eclipse. ,
.
, :
,
:
, , ,
,
:
:
1. , :
, Expect
(), Send (),
IV-15-6
Eclipse
.
, Portal 60
, .
FAN 2U FAN 1U INUe,
Portal,
.
2. ,
INU/INUe,
Use Detected
For All ( ).
, :
, Send ().
:
,
Plug-ins. . . 7-1.
. Portal
( ).
IV-15-7
15.
Event Browser
Event Browser ( ), . 15-2,
, ,
Eclipse.
5000 ,
.
Event Browser . 15-9
Event Browser . 15-10.
15-2. Event Browser Eclipse
1
2
7
8
6
9
IV-15-8
Location () ,
.
Eclipse
:
=
=
=
.
=
=
=
=
=
=
All Occurrences ( ) ,
Events ().
.csv .
,
.
, All Occurrences
Description.
Event Browser
,
, .
()
.
/
(
).
0,1
.
( ), ,
.
All Occurrences ( )
Show Occurrences ( ).
IV-15-9
15.
,
() Event box ( ). ,
SESR, All Occurences
SESR ,
. , ,
,
,
.
Description ()
Show Description ( ).
.
Event Browser
INU , INU
.
.
, /
.
/
. ,
Date/Time, /.
Active Only ( )
.
Auto Scroll ()
Auto Scroll Event Browser ,
. ,
.
Export Events ( )
, Save-In ( ),
My Documents ( ).
Excel CSV- .
Active-Only , .
Active Only, .
CSV, Export ,
Edit > Preferences.
Portal . 3-5, IV.
IV-15-10
Eclipse
IV-15-11
15.
Helpset
, e Help for Event
( ) .
, Helpset ,
Help for Event. Portal Helpset,
,
, Helpset.
Helpset Portal
" Eclipse" (
Helpset) Help; Portal
F1.
, Help for Event .
(
) DAC GE DAC 155oM;
.
Help for Event
.
. 15-3 Help for Event Demodulator Not
Locked ( ).
Show Occurrences ( )
, All occurrences ( ).
,
() .
Show Description ( )
, Description ().
.
Show Occurrences Show Description
.
IV-15-12
Eclipse
15-3. :
IV-15-13
15.
Alarms
Alarms
, . 15-4.
,
. . Alarms . 15-15.
15-4. Alarms
1
2
3
4
IV-15-14
.
,
.
Eclipse
, :
Reset History ( ),
.
( HSX Help ).
Alarms
Module (). Alarms Eclipse
INU. Select new module (
), .
LINK 2 (RAC 2). Eclipse,
.
. ,
. , ()
.
, .
. . Portal . 1-3, IV,
1.
,
,
-.
:
Reset History ( )
Reset History ( ), .
,
IV-15-15
15.
, ,
, .
Help for Alarm ( )
Help for Alarm
HSX Help (Helpset),
,
.
, " ",
Eclipse Portal
. 2-23 " " 5.
Help for Alarm Help for Event ( Portal Event Browser)
Helpset.
Portal
Helpset .
Install HSX Help Helpset
Eclipse.
> Program Files > HSX Help,
, Portal .
Helpset -
" Eclipse",
" ProVision", "
Harris Stratex Networks"
" VoIP."
,
; ,
HSX Help ,
.
:
, HSX
Help. HSX
Help. ,
HSX Help,
HSX Help.
Portal/Helpset,
,
.
Helpset ( ),
Help for Alarm , Help for
Alarm Help Not Installed ( ).
IV-15-16
Eclipse
Helpset
, e Help for Alarm
( ) .
Helpset ,
Help for Alarm. Portal Helpset,
, ,
Helpset.
Helpset Portal
" Eclipse" (
Helpset) Help; Portal
F1.
, Help for Alarm .
.
Help for Alarm
.
. 15-3 . 15-13 Help for Alarm
Demodulator Not Locked ( ).
IV-15-17
15.
History
History RAC Ethernet.
RAC ,
. :
History / Graph: RAC
History / Reports: RAC
DAC ES, DAC GE IDU ES, History
.
:
History: Ethernet
IV-15-18
Eclipse
15-5. History 15
1
2
3
Detail () 12
15 , 1 24 .
IV-15-19
15.
.
,
,
.
.
15-6. History
IV-15-20
RAC
Detail RAC.
, ,
.
Eclipse
History / Graph
Resolution () : 15-
24-. 15- 15
; 24-
.
View Detail As ( ) ,
(Graph)
(Report).
Graph 15 (24 )
G.826, ,
RSL.
Report :
G.826, G.821, RSL, Event () Configuration (). .
. 15-7 . 15-23.
Graph > 15- ,
12 15
.
-
.
-
.
15- (
24-) ,
.
15 ,
.
FIFO-. ,
15 ,
.
1,5 RSL.
, ,
.
IV-15-21
15.
IV-15-22
Eclipse
History / Report
.
/
.
. 15-1 .
IV-15-23
15.
15-1.
G.826 History
G.826
.
G.821 History
(lowest), (highest)
(average) BER
.
RSL History
(lowest),
(highest)
(average) RSL
.
Event History
.
, Event Browser. .
Diagnostics > Event Browser.
Configuration History
(software) /
(configuration),
.
History: Ethernet
Ethernet DAC ES, IDU ES DAC GE.
RAC, 15
24 :
15- - 15
.
24 -
.
:
(Tx) (Rx) Ethernet
(events)
(configuration)
. 15-8 .
IV-15-24
Eclipse
IV-15-25
15.
/.
. . 2.
/
Detail () , . 3.
12 .
( )
INU/INUe/IDU.
, -48
. , .
/,
Detail.
.
15 ( 7 ).
Detail.
.
Detail ( )
( )
.
( )
-.
( )
,
,
.
IV-15-26
Eclipse
Detail.
.
.
- (Tx)
(Rx) .
, ,
, .
,
. . 7.
( )
( 2).
, .
,
- ,
Incomplete (). . 6.
i)
, .
.
, Ethernet Stats
( Ethernet), . 4.
ii) ( ),
- .
.
Report, . 4 6.
iii) ,
( )
. ,
Events (). . 5.
Event Browser.
iii
IV-15-27
15.
Events (). ,
Detail, .
Event Browser. INU/
INUe/IDU - Ethernet-.
, ,
Ethernet-
Eclipse.
IV-15-28
Eclipse
Configuration (). ,
Detail,
Eclipse.
,
-.
Ethernet, ,
Incomplete ().
Incomplete ,
,
.
- ,
Portal/ProVision, INU/INUe/IDU.
- ,
;
Eclipse.
(onfiguration changes)
(software changes)
Events
,
, .
.
IV-15-29
15.
LINK AUTO /.
LINK /
;
Ethernet /.
/
LINK.
AUTO
, Auto
Duplex-Speed ( ) / MdiX, Plug-ins
DAC ES/GE ,
()
.
IV-15-30
Eclipse
Performance
Eclipse, Performance ()
:
Performance . 15-31
Performance NCC . 15-33
Performance DAC ES IDU ES . 15-33
Performance DAC GE . 15-41
Eclipse, Radio Controller ,
, Link NCC,
.
Export,
Excel
CSV Portal.
CSV,
Export , Edit >
Preferences. Portal . 3-5,
IV.
Performance
Performance , . 15-9,
G.826 , (Tx),
RSL, PA, -48 .
ODU, BER (
(Rx) ). RAC 40,
-
.
RAC.
IV-15-31
15.
15-9. Performance
, RAC 3 RING 3.
(RAC 3).
Export (),
.csv.
Performance
Select new module (
).
Available Performance Monitors RSL, Remote Fade Margin
( ), Tx power ( ),
Current BER ( BER), G.826, ,
-48 . ODU
- , RAC 40
( XPIC).
Performance .
, Start All ( ).
G.826 , Portal,
IV-15-32
Eclipse
Performance NCC
Performance NCC NCC
-48 . NCC.
Perfomance .
IV-15-33
15.
DAC ES.
Start All ( )
RMON.
DAC ES.
Export (),
.csv.
Performance DAC ES
DAC ES Module ().
, Performance Statistics (
) . ,
Start All ( ).
, Portal, Stop
All () Clear All ( ).
.
Portal
.
IV-15-34
Eclipse
Stop All ( ) ,
, / .
Clear All ( ) .
, , DAC ES
, ,
.
. 15-3 .
15-3. RMON
DAC ES
In Ucast Pkts
,
(),
.
In Broadcast Pkts
,
(),
.
In Multicast Pkts
,
(),
.
MAC-,
(Group) ,
(Functional) .
HC In Octets
, ,
.
64- If In Octets.
In Discards
,
, ,
.
.
,
,
, ,
.
IV-15-35
15.
,
,
, ,
.
,
,
,
,
. MAC-,
(Group) ,
(Functional) .
HC Out Octets
, ,
.
64- If Out Octets.
, ,
,
FCS.
, " "
(frame-too-long) " "
(frame-too-short).
, ,
, frameCheckError
MAC- LLC (
MAC-). ,
, IEEE 802.3 Layer
Management ( IEEE
802.3), ,
LLC.
,
10 /,
FCS.
IV-15-36
Eclipse
, ,
FCS.
, ,
, alignmentError
MAC- LLC (
MAC-). ,
,
, IEEE 802.3 Layer
Management ( IEEE 802.3)
,
LLC.
8- .
, ,
.
, ,
, frameTooLong
MAC- LLC (
MAC-). ,
,
, IEEE 802.3 Layer
Management ( IEEE
802.3), ,
LLC.
,
,
- .
() , ,
,
()
.
* ,
.
IV-15-37
15.
,
.
,
.
,
.
, ,
ifOutUcastPkts, ifOutMulticastPkts,
ifOutBroadcastPkts,
dot3StatsSingleCollisionFrames.
,
.
,
.
, ,
ifOutUcastPkts, ifOutMulticastPkts,
ifOutBroadcastPkts,
dot3StatsMultipleCollisionFrames.
,
.
,
,
. ,
, ,
.
,
.
IV-15-38
,
FCS.
. FCS,
.
Switch Stats
Undersized Frames
, 64 ,
FCS.
Eclipse
Switch Stats In
Fragments
, 64
FCS.
Switch Stats In 64
Octets
, 64 ,
.
, 65 127
, .
, 128 255
, .
, 256 511
, .
, 512 1023
, .
, 1024 MaxSize
, .
, MaxSize
, FCS.
802.1Q :
,
. ,
- ,
.
802.1Q :
, ( ),
- VID
(, VID VTU).
, FCS.
(,
) FCS ,
,
FCS, ,
. , FCS
FCS Switch Stats
Out FCS Errored.
, 64
, .
IV-15-39
15.
IV-15-40
,
65 127 ,
.
,
128 255 ,
.
,
256 511 ,
.
,
512 1023 ,
.
, 1024 1522
, .
Eclipse
Performance DAC GE
DAC GE
, DAC ES. . Performance DAC ES IDU ES
. 15-33.
Performance DAC GE
DAC GE .
, Performance Statistics (
) . ,
Start All ( ).
, Portal, Stop
All () Clear All ( ).
.
Portal
.
Stop All ( ) ,
, / .
Clear All ( ) .
, , DAC GE
, ,
.
. 15-4 RMON,
.
15-4. RMON
DAC ES
InUcastPkts
(Unicast) .
InBroadcastPkts
. (InBroadcasts)
InMulticastPkts
.
(InMulticasts)
HCInOctets
,
FCS (64 ).
(InGoodOctets)
IV-15-41
15.
IV-15-42
InDiscards
,
-
. (InDiscards)
OutUCastPkts
. (OutUnicasts)
OutBroadcastPkts
. (OutBroadcasts)
OutMulticastPkts
.
(OutMulticasts)
OutMulticastPkts
. (64
) (OutOctets)
Dot3 InPauseFrames
Dot3 FCSErrors
,
,
FCS.
Dot3 AlignmentErrors
,
, .
Dot3 FrameTooLongs
,
FCS, 1518 .
Dot3 OutPauseFrames
Dot3 StatsLateCollisions
,
.
Dot3 ExcessiveCollisions
, 16
.
Dot3 MultipleCollisionFrames
,
.
Dot3 SingleCollisionFrames
,
.
Dot3 DeferredTransmissions
,
, .
Eclipse
InBadOctets
,
FCS.
.
FCS, .
UndersizedFrames
, 64
, FCS.
InFragments
, 64
, FCS.
In64Octets
, 64
, .
In127Octets
, 65
127 ,
.
In255Octets
, 128
255 ,
.
In511Octets
, 256
511 ,
.
In1023Octets
, 512
1023 ,
.
InMaxOctets
, 1024
MaxSize ,
.
InJabber
,
MaxSize , FCS.
InFiltered
802.1q :
,
.
, -
, .
802.1q :
, (
),
- VID ( ,
VID VTU).
IV-15-43
15.
IV-15-44
OutFCSErrored
,
FCS.
Out64Octets
,
64 ,
. (Out64Octets)
Out127Octets
,
65 127
, .
Out255Octets
,
128 255
, .
Out511Octets
,
256 511
, .
Out1023Octets
,
512 1023
, .
OutMaxOctets
,
1024 1522 ,
.
Collisions
Eclipse
System/Controls
System/Controls
LINK (RAC/Radio), DATA (DAC/Trib) AUX.
:
Link Menu . 15-45
Ring . 15-54
DAC/ . 15-58
AUX . 15-68
. 15-68
Link Menu
. 15-11 . 15-47 System/Controls
LINK Eclipse.
. 15-12 . 15-48 System/Controls
Eclipse LINK.
Link . 15-50.
LINK :
Tx Mute: ODU.
Digital Loopback:
.
IF Loopback: .
RAC 10 Eclipse 100.
RAC 40 , RAC 40
(
XPIC,
XPIC).
AIS/PRBS
. 15-64.
,
(Tx) (Rx).
(Tx) / (Rx)
.
IV-15-45
15.
. , RAC/
. , RAC
( ),
.
, On. .
. 15-51. :
Test for 60 seconds ( 60 )
On () .
Always on ( ) ( )
. 15-21 . 15-69.
Event Browser Alarm
Link.
Link :
Portal.
, (Test LED) NCC
.
, (Status LED) IDU ODU
, :
,
(Status) IDU .
(Tx), (Status)
ODU .
IV-15-46
Eclipse
15-11. System/Controls :
INU/INUe
1
2
(Tx)
RAC.
RAC ,
RAC (Tx), RAC
(Rx).
, RAC
(Rx) .
(Tx) (Rx)
. .
.
( RAC ),
,
(Rx), :
RAC , ().
IV-15-47
15.
15-12. System/Controls :
IDU
1
2
IDU,
Portal.
, .
IV-15-48
Link.
Eclipse
(Tx
mute) (loopbacks).
Diagnostic Safety Timer (
).
Unit protection ( ).
- ,
.
, IDU
(Tx) (Rx).
(Tx) (Rx),
.
IV-15-49
15.
Link
Lock () ,
:
, RAC
, RAC
( (Rx)).
(Tx) / (Rx) RAC
,
Auto Primary () Secondary
(), Auto.
IDU, ,
(Tx) (Rx).
,
Auto Secondary (),
Auto.
:
1. Lock ().
2. Safety Timer ( )
OK. . .
3. , Send ()
, .
4. Off (Auto), Send,
,
.
, 2 (
2 ),
.
IDU 155o IDU300 20xV2 ,
(Tx),
(Rx), , (Rx) (
(Rx) Off () /Auto ()).
(Tx)
Tx Mute ( ), (Tx)
, /
silent transmitter (
) ( /
IV-15-50
Eclipse
/ ).
, (Tx) (Tx Lock On).
IF loopback ( ) digital loopback (
)
(
/ ).
Eclipse IDU 300
, .
IDU 100
.
RAC/
. , (Digital (
) IF ( )) RAC/
. , ,
( )
, , RAC/
.
. 15-13 .
,
Send.
, :
Portal (. ).
,
Edit > Preferences.
Portal. . Portal . 3-5, IV, 3
, . 15-13,
:
IV-15-51
15.
.
1
On ().
Ok.
Do not ask me this again (use this setting as
default) ( (
),
On () System/COntrols
Portal, Safety Timer ,
.
Advanced (),
always on ( ).
Safety Timer,
On (),
Off ().
IV-15-52
Send .
.
always on, off, Send.
,
On.
Eclipse
15-13.
1
.
Do not ask me this again (use this setting as default) (
( ),
Edit > Preferences Diagnostic safety timers
( )
. ,
, Edit >
Preferences Portal, .
IV-15-53
15.
Ring
. 15-14 . 15-55 System/Controls .
:
Protection Controls ( );
East
() West () Online () Offline
().
RAC East (RAC );
(Tx) RAC (East RAC Tx Mute),
(digital) (IF).
RAC West(RAC );
(Tx) RAC (West RAC Tx Mute),
(digital) (IF)..
, On.
:
Test for 60 seconds ( 60 )
On () .
Always on ( ) ( )
. Ring . 15-55.
.
15-21 . 15-69.
Event Browser Alarm
, ,
Portal,
(Test LED) NCC .
IV-15-54
Eclipse
15-14. System/Controls
1
2
3
4
(Tx) .
Protection Controls ( ).
.
[ ] .
,
. (
).
(Tx) (Rx)
.
Ring
. 15-15 Online () Offline
(). .
IV-15-55
15.
Online RAC/DAC ;
.
, ,
.
(Lock Online > Send > Off (Auto) > Send)
Error-free Timer ( ) (,
).
. 3-124, II, 3.
Offline -
RAC.
, /
,
( ,
).
, Countdown Timer ( )
Offline.
Error-free Timer
Protection, ,
, (,
).
Countdown Timer, Online: lock Online > Send > Off
(Auto) > Send.
Countdown Timer ,
. ( ).
Error-free Timer, Delay Ring Unwrap Timer.
Protection.
, IV, 8.
. 15-51.
IV-15-56
Eclipse
15-15.
Online Lock West
RAC/DAC
RAC, East / West ( / )
Tx Mute ( ) (IF)
(digital).
Link/RAC DATA/DAC 155oM.
(Tx)
. 15-50, Tx Mute
,
.
DAC 155oM, East / West
:
(Line Interface) (
) (line-facing)
(bus-facing).
IV-15-57
15.
AIS .
(Bus Ports) (NxE1/DS1)
.
. .
. 15-51.
DAC/
Eclipse, DAC ,
DAC.
PDH SDH Eclipse,
(NxE1, NxE1/DS1, STM1/OC3, Ethernet) IDU.
:
System/Controls DAC: DAC PDH SDH . 15-58
AIS . 15-61
PRBS . 15-61
DAC . 15-63
. 15-64
IV-15-58
Eclipse
Link.
Link :
Portal.
, (Test LED) NCC
.
, (Status LED) IDU
.
15-16. System/Controls DAC 16xE1
2
3
IV-15-59
15.
,
1.
,
3.
PRBS.
,
Plug-ins.
On AIS Safety
Timer ( ).
IV-15-60
Eclipse
AIS
Diagnostic Safety Timer,
AIS ,
. 15-51.
DAC ES DAC GE (Ethernet) AIS.
IDU ES AIS Ethernet-;
.
PRBS
DAC E1/DS1, E3/DS3 STM1/OC3 IDU E1 E1/
DS1 PRBS G.821
. Generator ()
BER 215-1.
DAC/IDU
PBBS G.821.
, PRBS DAC/
IDU G.821 DAC/IDU .
PRBS
.
G.821 10 ;
10 .
DAC PRBS TDM-.
G.821
.
BER-
.
PRBS G.821
G.821, 10 ,
, PRBS Generation (
PRBS); 10 Send.
, PRBS
DAC/IDU ,
PRBS DAC/IDU. DAC/IDU
10 .
PRBS, Reset ().
IV-15-61
15.
AIS
PRBS
AIS/PRBS
, :
RAC/,
(AIS PRBS15)
/. -
RAC/, DAC /
RAC, AIS/PRBS. DAC/
,
AIS/PRBS .
, .
DAC/IDU E1, DS1, E3, DS3, AIS
( ).
DAC/IDU STM1/OC3, PRBS15 (15-
)
(
).
DAC/IDU
,
RAC/
.
:
PDH, AIS
.
IV-15-62
Eclipse
SDH, PRBS
( BERT
).
, AIS/PRBS .
, ,
,
() .
,
,
AIS PRBS15
/.
- RAC/,
DAC /
RAC, AIS/PRBS.
AIS/PRBS15
DAC, System Control.
DAC
DAC
/DAC . 3-115, II, 3.
(Tx) (Rx) RAC :
(Tx) (Rx).
.
DAC () DAC ()
, AIS PRBS,
. 15-16 . 15-59 DAC.
DAC,
DAC.
IV-15-63
15.
15-17. DAC E3
1
2
DAC 2xSTM1
Protection () (Tx)
(Rx).
Configuration >
Plug-ins.
(),
Trib 1,
.
IV-15-64
Eclipse
1
2
, Port1 - Channel 1 . 2 4
Channel 2 .
IV-15-65
15.
1 155 /c,
(Tx) ( ).
Mode of Operation ( ),
Plug-ins. , Dashboard
Detailed.
Dashboard Detailed
Dashboard Detailed ( )
,
.
.
15-19. Dashboard Detailed DAC GE
IV-15-66
, Dashboard
(Tx) ~150 /c (Rx) ~50 /c.
Eclipse
Channel 1 ( 1).
(Tx)
~20% ( 190 /c, P1 C1 150 /
c, ).
Port/Channel Status
Port/Channel Status ( /) :
.
(Tx) (Rx)
.
( DAC GE)
(Tx) (Rx) (
DAC GE).
(Tx) (Rx)
.
DAC ES DAC GE,
, .
. 15-20 .
, - . ,
- Plug-ins.
IV-15-67
15.
AUX
System/Controls AUX
;
AUX, AUX IDU.
.
. 15-21 INU/INUe
RAC 30 DAC 16x. IDU,
:
RAC 3X RAC 40 , RAC 30.
RAC 10 ;
.
DAC PDH/SDH
(E1/DS1, E3/DS3, STM1/OC3).
DAC ES
DAC GE.
AUX ;
DAC .
IV-15-68
Eclipse
IDU 100 ,
( 1,
, ).
IDU 300, IDUsp,
( PDH/SDH-, ,
). IDUsp , .
15-21. INU/INUe Eclipse
DAC 16x
RAC 30
1
ODU
IF
MOD/DEMOD
MUX/DEMUX
TDM-
MUX/DEMUX
LIU
16
DAC
RAC
.
.
RAC/
RAC/. Digital ( ) IF ().
.
.
Circuit Loopbacks Eclipse
. 15-71.
: ODU- . ,
ODU :
ODU. RAC
IDU, :
RAC 30 (RAC 30V1 RAC 30V2a).
RAC 10.
IV-15-69
15.
IV-15-70
Eclipse
IV-15-71
15.
1
2
(LINK, DATA, AUX)
, Circuits,
.
.
.
.
Circuit Loopbacks
,
Circuits.
. .
IV-15-72
Eclipse
, -, (tributary
( ) auxiliary ( )).
,
:
Search-by-name ( )
Starts with ( ) Contains
().
For-component ()
; LINK, DAC, AUX.
.
, ,
.
,
Activate Circuit Loopback ( ).
. De-activate (),
.
, Circuits
.
IV-15-73
15.
Parts
Parts () :
Part number ( )
Part revision ( )
Serial number ( )
Time -in-service ( )
:
INU FAN
IDU
ODU
. 15-23 RAC 1 / ODU 1.
.
. .
15-23. Parts
IV-15-74
Eclipse
Advanced Management
Advanced Management :
,
. . Software Reset . 15-76.
,
Event Browser History. . Clear Events and History . 15-77
15-24. Advanced Management
3
4
IV-15-75
15.
Software Reset ( )
.
. Portal Help Desk
.
Clear (),
Event Browser History.
Recover (),
.
, ()
Portal.
Software Reset
Software reset ( )
:
NCC ODU Eclipse.
ODU Eclipse.
( - - ),
: Helpdesk Data File (
)
Portal C:\Program Files\Portal\Reset Logs\.
"", IV 5.
,
, ,
. .
Eclipse
,
.
Eclipse :
Event Browser Help for Event.
Alarms Help for Alarm.
IV-15-76
Eclipse
" " .
Portal . 2-23,
V, 2.
IV-15-77
1.
Eclipse.
:
-
,
Harris Stratex Networks.
Eclipse , :
e ,
Eclipse , INU/INUe
.
V-1-1
1.
, ,
INU/INUe Eclipse
, .
Eclipse (
Exel)
, . .
. 1-25.
, Eclipse,
.
. 1-1.
1-1.
,
,
.
II, 5.
RSL 2
.
Portal,
, ,
, :
.
.
.
IP- ,
ProVision,
.
,
. . -
. 1-4.
. .
. 1-25.
V-1-2
Eclipse
/ ,
. . . 1-25
V-1-3
1.
-
:
BER
BER
BER
BER-
, , 8 12
().
:
,
. . . 1-4.
BER ,
BER. . BER
. 1-5.
Eclipse G.826
, RAC RAC.
( ).
G.826 Portal Performance. .
IV, 11.
.
Harris Stratex
Networks.
G.826 Portal History.
. IV, 11. ,
15- - , 24-
- .
V-1-4
Eclipse
BER
BER
BER- Eclipse.
,
,
, .
DAC E1/DS1, E3/DS3 STM1/OC3
PRBS G.821
:
DAC
PBBS G.821. /,
Portal
.
, PRBS
DAC G.821 DAC
. .
Eclipse DAC, RAC
.
System/Controls . 15-45, IV Circuit Loopbacks
Eclipse . 15-71.
BER-, . .
,
.
() .
,
(Tx), ,
, ,
,
.
, ,
, .
(BER) 10-6 10-3. Eclipse 10-3
V-1-5
1.
10-6 2 .
, RSL, Portal Performance,
. RSL ,
.
,
,
.
Eclipse
()
G.826,
Portal Performance.
RSL ,
(Tx).
,
.
, ,
, Portal,
. ,
()
.
Portal:
Configuration > Plug-ins > Link (Tx)
ATPC.
Diagnostics > Performance > Link RSL G.826.
Diagnostics > System/Controls > Link
.
:
1. , ATPC,
.
2. ()
.
3. RSL .
V-1-6
Eclipse
4. Performance
. , BER-
.
5. (),
,
.
6. ()
(Rx).
7. RSL, ,
-
.
V-1-7
1.
,
:
. Eclipse
34 ,
, RSL G.826.
,
4 ,
RSL BER.
, BER .
.
.
.
.
" " " "
Harris Stratex
Networks.
, ,
DAC NCC/NPC Eclipse.
:
. 1-9
. 1-10
. 1-13
. 1-14
. 1-17
. 1-18
DAC . 1-20
DAC . 1-22
V-1-8
Eclipse
NCC/NPC . 1-23
1-2
(), ,
Portal.
;
.
.
- (FAT).
Harris Stratex
Networks .
BER G.821
G.826:
BER- ( DAC) BER
.
BER- BER-
; ,
,
,
1 2 ,
.
(
), . , 50
000 24 E1 (E1 = 2 048 000
).
G.826
Performance.
G.826
;
, ,
,
1 2 ,
.
V-1-9
1.
ODU
, , , ,
; /
.
, ,
Eclipse.
, ,
G.826 BER- G.821.
BER- BER-,
DAC, .
: , .
,
:
. 3-92.
II, 3.
G.
RAC/ODU
.
Protection.
RAC ( ODU)
RAC, .
. System/
Controls.
RAC ( ODU)
RAC, .
. System/
Controls.
:
(Tx) RAC
( : RAC).
V-1-10
Eclipse
(Rx) RAC
( : RAC).
.
,
(Tx) RAC .
(Tx)
RAC.
, (Tx)
RAC.
(Tx)
.
, (Tx)
. (Tx)
.
, ,
RAC
,
.
(Rx) (
/ ) ,
(Rx) RAC .
(Rx) RAC
.
(Rx)
RAC, ,
(Rx) RAC ( RAC).
RAC
System/Controls
(Rx) RAC
- RAC,
.
V-1-11
1.
c
, ,
,
(Rx)
(Tx) RAC.
System/Controls
RAC RAC.
,
,
RAC (
(Tx)).
,
ODU RAC,
,
,
. ,
RAC ,
48 .
ODU.
, Protection
RAC (East)
(West) .
:
,
RAC, RAC (
).
.
,
RAC, RAC (
).
;
, (
, )
, .
( ).
,
,
( ),
.
NMS.
V-1-12
Eclipse
,
- / .
AUX .
/
NMS; NMS,
/ .
:
:
:
Portal
(/0).
G.826 Performance.
/ /
RAC .
/ ,
(Tx) RAC,
(Rx) RAC.
System/Controls .
RAC,
, .
RAC online LED ( )
, (Tx),
(Rx) (Tx) (Rx). ,
(Tx) (Rx).
:
BER- PRBS,
DAC E1/DS1, E3/DS3 STM1/OC3,
BER-.
. ,
PRBS
V-1-13
1.
, (
).
Portal
..
RAC.
RAC, RAC.
PRBS :
, ,
Errored Second ( ) 1 ,
,
2. . 1-9.
Available/Unavailable (/
) , Severely Errored Second
( ) Errored
Second.
, ,
.
, System/
Controls, , RAC, ,
, . ,
Auto / Lock Off.
, , 5
, .
5
,
. ,
-
2 ,
, Portal.
(Tx) .
(Rx) ,
(Rx) RAC .
:
V-1-14
Eclipse
(Tx) :
(Tx),
(Tx).
(Tx) "" .
(Tx),
(LOS) .
(Rx).
(Tx)
RAC.
:
1. BER- DAC
. .
2. RAC (
) , (Tx)
(Tx) ( RAC).
3. ,
( )..
. 1-9.
, (status LED) NCC
,
Portal
( ).
4. RAC ,
; (Tx)
RAC, (Tx)
(Rx).
5. 60 , (status LED)
NCC RAC ,
RAC ,
( ).
RAC (Tx)
(Rx).
6. , ,
.
7. System/Controls
( RAC (Tx),
RAC (Rx)),
, ,
(Tx)
V-1-15
1.
.
"" (Tx)
(Tx)
.
:
1. BER- DAC
.
.
2. System/Controls .
3. Tx Mute ( ) RAC
(Tx), Send ().
.
(Tx) RAC ( (Tx)
RAC).
4. , 20 .
RAC (Tx)
(Rx).
"" (Tx). ,
3 . LOS
, 5-
. LOS , ,
, 320
. (
),
.
V-1-16
Eclipse
.
(Rx).
ODU
RAC.
:
1. Diagnostics > Performance > Start All
. ,
.
2. ODU RAC
Performance, .
RAC (Tx)
(Rx).
3. ODU RAC, 30
, ODU RAC
, .
RAC (Tx)
(Rx).
(Rx) ( )
ODU
(Tx) RAC.
(Rx).
4. System/Controls
(
RAC (Tx), RAC (Rx)),
,
, (Tx)
.
(Tx) , RAC
. ( RAC ,
(Tx)
(Tx) RAC).
(Rx) .
(Tx) (Rx)
ODU
RAC.
:
V-1-17
1.
1. BER-
. .
2. ODU RAC ,
.
RAC (Tx) (Rx) .
3. ODU RAC, 30
, , (online LED)
, ODU RAC
, .
RAC (Tx)
(Rx) .
4. System/Controls
(
RAC (Tx), RAC (Rx)).
( )
.
, "" (
" ").
,
.
- "",
; ,
.
"" ( ) .
(Tx)
.
:
1. BER- .
.
2. Diagnostics > System Controls
.
3. Tx Mute RAC, Send.
(Tx)
"" .
4. ,
( ). .
. 1-9.
V-1-18
Eclipse
5. ODU ,
c 5- . ,
,
,
( ).
6. 2- 5- RAC.
A.
V-1-19
1.
DAC
DAC/ (
DAC)
DAC.
DAC:
DAC 3xE3/DS3
DAC 3xE3/DS3M
DAC 1x155o
DAC 2x155o
DAC 2x155e
DAC 155oM
DAC .
DAC (Tx)
(Rx).
(Tx) (Rx)
, ,
, DAC (Tx),
(Rx).
(Tx) / (Rx)
.
.
: "" " ".
: (TT):
DAC
Y-.
(Rx) ( ) DAC
, (Rx)
DAC TDM-.
(Tx) (Tx)
DAC ,
(Tx) .
: (TA):
DAC
.
V-1-20
Eclipse
(Rx) ( ) DAC
, (Rx)
DAC TDM-.
DAC
,
"
" .
TA , INU/INUe Eclipse
DAC.
V-1-21
1.
DAC
:
DAC (Tx) (Rx)
, .
" : " (TT).
BER-
,
DAC .
BER-
. . . 1-9.
:
1. BER-
.
BER-,
DAC Y- .
, (Tx) (Rx)
DAC,
. (Tx) (Rx)
DAC, , (Tx)
, (Rx) ,
.
System/Controls
DAC.
(Tx) (Rx) () DAC,
AIS.
Portal
..
2. ( )
DAC ,
( ). DAC
(Tx) (Rx)
.
, (status LED) NCC
,
Portal
( ).
3. DAC ,
(Tx) (Rx)
;
V-1-22
Eclipse
DAC.
4. 30 , (status LED)
NCC DAC ,
DAC ,
( ).
DAC (Tx)
(Rx) .
5. , ()
() .
, DAC
(Tx), -
(Rx). System/Controls
.
NCC/NPC
NPC
TDM- NCC.
NCC, NPC
; /
.
TDM-
. 100
, .
. NCC
, NPC .
. ( NPC ;
).
TDM-
NPC, NCC
. NCC
/ NPC,
System/Controls.
,
.
NCC.
NPC, NCC
, .
NCC, NPC
, .
V-1-23
1.
NCC/NPC.
BER-
,
. . . 1-9.
1. BER-
.
.
2. , (Status LED) NPC ,
(Protect LED) .
3. 48 NCC
, - ( ).
(Protect LED) NPC ,
, NPC.
4. NCC .
NCC , Portal
, "" .
, ,
NCC,
.
5. NCC .
TDM- NPC,
(Protect LED) NPC.
6. NCC , , 3
(
Portal), BER-,
NPC , -
( ).
NCC INU/INUe,
NPC. 3 .
, NCC
,
.
3
NCC, NPC.
7. NPC .
(Status LED) NPC ,
(Protect LED) .
V-1-24
Eclipse
As Built Report Portal
/
.
csv, Excel- .
/
.
, Excel (
)
.
Eclipse,
Harris Stratex
Networks. Eclipse .
.
- :
.
.
.
.
:
.
.
.
. 1-1
- .
V-1-25
1.
1-1. -
V-1-26
2.
Eclipse
:
. 2-1
. 2-3
Eclipse . 2-14
Portal . 2-23
Portal Diagnostics . 2-40
. 2-45
:
ProVision Portal -
.
Harris Stratex Networks
ProVision Portal
ProVision - Harris Stratex Networks.
Eclipse ProVision Portal,
Eclipse, ,
.
V-2-1
2. Eclipse
,
Portal. Portal
Eclipse ProVision. ,
Portal, ProVision.
,
Eclipse.
,
. :
Eclipse
ProVision
Harris Stratex
Networks
Harris Stratex
Networks
, .
.
.
,
.
-
United Kingdom
.:
americas_help@hstx.com
V-2-2
.:
.:
emea_help@hstx.com
asia_help@hstx.com
Eclipse
:
ProVision . 2-3
. 2-4
. 2-5
. 2-8
. 2-10
AIS PRBS
. 2-13
ProVision
ProVision ,
, .
ProVision
:
/
ProVision
,
INU/INUe Eclipse.
Eclipse , ProVision Portal
Eclipse. Portal
(NOC) Portal,
.
, , ,
,
,
, ,
. , Portal Alarm, Events Browser
History, .
Eclipse :
Portal Diagnostics . 2-40
ProVision
V-2-3
2. Eclipse
, ,
:
?
, .
,
, Eclipse ( ),
, / ODU,
, (,
, , ). :
Eclipse
?
, ,
BER?
?
, , Eclipse,
Eclipse?
, ?
?
,
?
(, ,
, )?
-
,
, , .
?
?
Eclipse?
-
?
V-2-4
Eclipse
, :
.
,
ODU.
ODU,
/ .
Portal
Ethernet/V.24. Ethernet-,
IP- / Eclipse,
.
,
"" .
- ,
, , BER-.
.
() .
Harris Stratex Networks, 9, "
".
Eclipse:
.
,
. . Eclipse . 2-14.
, (Status LED) (
), INU/INUe ,
,
.
System Summary. Eclipse
Portal System Summary.
, :
,
.
V-2-5
2. Eclipse
Portal Alarms. . Portal . 2-23.
,
.
.
, ,
, ,
.
, (
), .
Portal History ( 15 ) Events,
,
RSL BER
, , ,
, . .
. 2-8
.
, .
,
-
. ,
, Portal Diagnostics.
, .
. , ,
,
() :
,
.
NCC/IDU, .
( ),
NCC/IDU.
-
,
Eclipse.
V-2-6
Eclipse
,
RAC/.
NCC ,
,
,
.
RAC ODU. ,
RAC/IDU ODU,
RAC/IDU, .
" ". INU/INUe "
". ,
, , .
NCC ,
, NPC.
.
:
60 . ,
(Status LED), RAC
(Online LED). ,
RAC
, (Tx)
(Rx). (On-line LED)
RAC ,
(Tx) / (Rx).
NCC NPC,
NCC "" , ,
Portal.
NCC NPC,
TDM- NCC,
( )
NPC.
NCC , ,
NPC,
Systems/Control Portal NCC,
NPC.
NPC
NCC; NPC
NCC.
V-2-7
2. Eclipse
NCC.
,
, ,
:
NCC
ODU. NCC
NCC/NPC, 3
, NCC
.
" ", 1.
, NMS-,
5
Eclipse.
, , ,
,
. ,
, .
ODU
ODU .
, RSL ,
, BER.
,
, .
, ,
, .
:
. 2-9
. 2-9
V-2-8
Eclipse
, ,
:
BER , RSL
,
, ,
.
13 .
- 11 .
,
.
-
RSL
, , .
,
.
ODU - .
,
- ,
.
.
, RSL .
,
.
, ,
ODU.
:
.
V-2-9
2. Eclipse
III, 5.
30 ,
.
RSL ,
, (Tx)
, ,
.
+/- 2 . 3
.
( )
,
.
, .
, .
:
: " "
(Configuration Not Supported)
"- " (SW/HW Incompatible):
/
NCC:
, , DAC 16x, AUX, RAC
, DAC 155o.
c .
, Portal Layout
/ . ,
RAC/ODU . RAC 30 RAC 40
ODU 300. RAC 10
ODU 100.
V-2-10
Eclipse
- :
INU,
.
,
Eclipse.
RAC
RAC 30v3:
RAC 30v1.
RAC 30v2 , INU/INUe
3.4 .
RAC 30 RAC 3X
. 3-19 II, 3.
( RAC 30v3 3.3 )
,
, . ,
.
,
() .
Portal -
; .
. A.
, BER-
Eclipse, ,
, BER-.
, ,
, , Circuits:
,
Portal Circuits.
, ,
, .
,
.
DAC AUX
:
V-2-11
2. Eclipse
,
: Trib (n) Uncommissioned Traffic.
, , ,
: Trib (n) LOS.
/
.
,
( LOS)
, BER:
DAC 16x DAC 4x. 1
. DS1
.
.
PDH,
.
ATPC
, ATPC , ,
(Tx),
. IV,
ATPC . 7-21.
ATPC XPIC
RAC 40.
ATPC ,
(Tx), RSL (
RSL ).
, /
, .
,
, : DAC ES, DAC 155oM AUX.
,
.
V-2-12
Eclipse
, Eclipse
Portal, :
:
, 10 .
.
, IV, 13.
.
IDU, ,
IDUsp. ,
II, 2.
AIS PRBS
AIS PRBS . 15-62, IV, 15.
.
,
.
-
United Kingdom
.:
americas_help@hstx.com
.:
.:
emea_help@hstx.com
asia_help@hstx.com
V-2-13
2. Eclipse
Eclipse
Eclipse.
INU/INUe
.
IDU .
()
:
(Status LED)
, -
, /
.
Eclipse
.
,
.
500
.
(On-line LED) RAC
,
. (Online LED)
() ,
RAC ,
(Tx), (Rx) RAC. (
RAC , RAC
, RAC
(Online LED)).
, , (Test LED)
(Status LED) NCC ,
, ,
.
INU/INUe,
(Status LED) ,
.
,
.
V-2-14
Eclipse
:
INU/INUe . 2-16
IDU . 2-20
V-2-15
2. Eclipse
INU/INUe
. 2-1 INU/INUe.
,
.
2-1. INU/INUe
NCC
Status
NCC Test
DAC
Status
AUX
Status
RAC
Status
RAC
Online
NPC
Statu
s
NPC
Protect
FAN
()
INU/
INUe
INU/INUe
INU/INUe
INU/INUe
INU,
ODU
RAC
TDM-,
RAC
INU/
INUe
,
RAC
(Rx)
TDM-
(
TDM-)
,
.
RAC
ODU
(Rx)
ODU
()
, ,
, , Portal Alarms. ,
NCC
V-2-16
Eclipse
, ,
, Portal.
. ,
NCC ,
, TDM-.
. 2-2 INU/
INUe .
,
Portal
, . Portal . 2-23.
2-2. INU/INUe
NCC Status
,
Portal
.
(
Eclipse)
TDM-
NCC
TDM- NCC
NCC Test
/
.
.
,
.
Portal
.
/,
Portal System Controls.
V-2-17
2. Eclipse
DAC Status
Eclipse
() DAC.
c
Eclipse.
:
LOS
FPGA
EEPROM
LIU
RAC Status
V-2-18
.
-
.
,
. Portal
.
Eclipse
() DAC,
Portal
ProVision
Eclipse.
,
,
()
.
Eclipse
.
,
.
Portal
.
ODU
(Tx)
RAC Online
():
RAC
.
(Online LED)
,
RAC ,
,
.
:
RAC
ODU
,
(Status LED) ,
RAC
(
(Status LED), (Online
LED) ),
.
System Controls.
RAC,
,
System Controls,
.
,
.
Portal
.
V-2-19
2. Eclipse
AUX Status
Eclipse
() AUX.
c
Eclipse.
NPC Status
.
,
.
Portal
.
TDM-
NPC
Portal System Controls.
.
.
,
.
Portal
.
FPGA
EEPROM
,
.
TDM-
NPC
FAN
FAN (
)
FAN.
IDU
. 2-3 IDU
.
IDU .
V-2-20
Eclipse
, , (Status LED)
, , ,
.
, .
2-3. IDU
IDU Status
,
Portal
.
:
LOS
IDU
IDU
ODU Status
:
/
.
, ,
.
-
.
,
. Portal
.
,
Portal
.
(
Eclipse)
V-2-21
2. Eclipse
.
,
.
Portal
.
ODU
ODU,
/
.
ODU
(Tx)
(Tx)
ODU
V-2-22
Eclipse
Portal
Portal
, ,
, , ,
.
:
Eclipse . 2-23
Eclipse . 2-34
, .
.
HSX Helpset,
,
.
pdf- "
Eclipse",
(,
"view history").
Eclipse,
. B.
.
B. ( ),
(All) ( ).
, ,
. Portal Alarms
, .
Eclipse
Eclipse
.
Alarms
, .
RAC DAC. , RAC
V-2-23
2. Eclipse
NCC
NCC
FPGA Software Load Failure (All)
RAM Failure
Flash Card Failure
Fixed Flash Failure
ADC Failure (NCC/IDU)
RTC Failure
Clock Generator Failure (NCC/IDU)
V-2-24
Eclipse
Temperature
Expansion NCC Communications Failure
Fan Failure (NCC)
Fan Plug-in Missing
NCC TDM Clock Failure
Configuration Corrupt
Configuration Not Supported (All)
Software/Hardware Incompatible (All)
Date and Time Not Set
n
Slot Plug-in Missing
Slot Plug-in Incorrect
RAC
RAC
V-2-25
2. Eclipse
RAC
Fuse Blown
FPGA Software Load Failure (All)
EEPROM Failure (All)
Clock Generator Failure (RAC)
Modulator Failure
Demodulator Failure (RAC)
Cable Demodulator Failure (RAC10/IDU)
ODU
ADC Failure (ODU)
FPGA Software Load Failure (All)
Clock Generator Failure (ODU 100)
Demodulator Failure (ODU100)
Tx NCO Failure (ODU100)
Cable Demodulator Failure (ODU100)
Cable NCO Failure (ODU100)
IF Temperature
Power Detector Temperature
Transceiver RX Temperature
ODU Communications Failure
Configuration Not Supported (All)
Software/Hardware Incompatible (All)
Remote Communications Failure
ODU
Software/Hardware Incompatible (All)
V-2-26
Eclipse
(Tx)
TX Synthesiser Not Locked
Transceiver TX Failure
TX IF Synthesiser Not Locked
Modulator Not Locked
RAC TX Cable IF Synth Not Locked
ODU TX Cable IF Synth Not Locked
Cable Demodulator Not Locked (ODU 100)
ODU TX Cable Unplugged
(Rx)
ODU TX Cable Unplugged
RX IF Synthesiser Not Locked
Demodulator Not Locked
RAC/IDU Cable Demodulator Not Locked
Tuner Not Locked
ODU Cable Modulator Not Locked (ODU 100)
ODU Cable Unplugged
RAC RX Cable IF Synthesiser Not Locked
(Rx)
ESR Threshold Exceeded
SESR Threshold Exceeded
V-2-27
2. Eclipse
DAC
DAC
FPGA Software Load Failure (All)
EEPROM Failure (All)
LIU Failure
Clock Generator Failure (DAC)
Configuration Not Supported (All)
Software/Hardware Incompatible (All)
n
Trib n Output AIS Enabled
Trib n Radio Facing Loopback
Trib n Line Facing Loopback
Trib n Link Test Enabled
TX Manual Lock
RX Manual Lock
n
TX Manual Lock
V-2-28
Eclipse
n
Trib n Output Failure
Trib n AIS
AUX
AUX
Alarm Input (n)
FPGA Software Load Failure (All)
Auxiliary Channel (n) Clock Failure
Configuration Not Supported (All)
Software/Hardware Incompatible (All)
1
AUX (n) Bus Facing Loopback
AUX (n) Line Facing Loopback
2
AUX (n) Bus Facing Loopback
AUX (n) Line Facing Loopback
3
AUX (n) Bus Facing Loopback
AUX (n) Line Facing Loopback
NPC
NPC
V-2-29
2. Eclipse
DAC ES
DAC ES
FPGA Software Load Failure (All)
EEPROM Failure (All)
Switch Access Failure
Configuration Not Supported (All)
Software/Hardware Incompatible (All)
n
Channel PRBS Test Active
Channel Loopback Active
V-2-30
Eclipse
n
Port Loopback Active
Port Monitoring Active
Direct Link Active
DAC GE
DAC GE
FPGA Software Load Failure (All)
EEPROM Failure (All)
LIU Failure
ICPU Failure
Configuration Not Supported (All)
Software/Hardware Incompatible (All)
ICPU Software Failure
V-2-31
2. Eclipse
n
Port Loopback Active
Port Monitoring Active
Direct Link Active
n
Transport Channel (n) Switch Packet Errors
Link Down
Link Degraded
n
Link Failure (DAC ES, DAC GE)
Dropped Frames Ratio (DAC ES, DAC GE)
DAC 155oM
DAC 155oM
FPGA Software Load Failure (All)
EEPROM Failure (All)
LIU Failure
Clock Generator Failure (DAC)
PMC TEMAP Access Failure
PMC OHT Access Failure
Configuration Not Supported (All)
V-2-32
Eclipse
n (1.5)
Trib n Output AIS Enabled
Trib n Radio Facing Loopback
Trib n Line Facing Loopback
Bus Trib z Loop-Back Enabled
Ring Manual Lock
n (1.5)
Trib n LOS
Trib n Uncommissioned Traffic
SONET/SDH
/
RDI In
AIS In
Signal Degrade BER
Signal Fail BER
LOS
LOF
OOF
, x (VC3/
STS-1,VC4)
Container x AIS
Container x LOP
Container x LOM
Container x RDI
V-2-33
2. Eclipse
Container x RPSLM
Low Order Path, Container/Trib y in Alarm
FAN
FAN
Fan Failure (FAN)
Eclipse
Eclipse.
,
.
:
IDU . 2-34
. 2-35
. 2-37
AUX . 2-38
Ethernet . 2-38
FAN . 2-39
IDU
IDU
FPGA Software Load Failure (All)
RAM Failure
Flash Card Failure
Fixed Flash Failure
ADC Failure (NCC/IDU)
RTC Failure
Clock Generator Failure (NCC/IDU)
V-2-34
Eclipse
IDU
Cable Demodulator Failure (RAC10/IDU)
Modulator Failure
Demodulator Failure (RAC)
ODU
ADC Failure (ODU)
FPGA Software Load Failure (ODU 100)
Clock Generator Failure (ODU 100)
Demodulator Failure (ODU100)
Tx NCO Failure (ODU100)
Cable Demodulator Failure (ODU100)
Cable NCO Failure (ODU100)
V-2-35
2. Eclipse
ODU PA Current
ODU -48V Supply
IF Temperature
Power Detector Temperature
Transceiver RX Temperature
ODU Communications Failure
Configuration Not Supported (All)
Remote Communications Failure
ODU
Software/Hardware Incompatible (All)
TX Power Mute
ATPC Disabled
Bus Facing Digital Loopback
Bus Facing IF Loopback
TX Manual Lock
RX Manual Lock
V-2-36
Eclipse
(Rx)
RX Synthesiser Not Locked
Demodulator Not Locked
RAC/IDU Cable Demodulator Not Locked
Tuner Not Locked
ODU Cable Modulator Not Locked (ODU 100)
RX IF Synthesiser Not Locked
ODU Cable Unplugged
(Rx)
ESR Threshold Exceeded
SESR Threshold Exceeded
10-3 BER Threshold Exceeded
10-6 BER Threshold Exceeded
Protection Cable Unplugged
LIU Failure
Configuration Not Supported (All)
n
Trib n Output AIS Enabled
Trib n Radio Facing Loopback
Trib n Line Facing Loopback
V-2-37
2. Eclipse
AUX
AUX
Alarm Input (n)
Auxiliary Channel (n) Clock Failure
Configuration Not Supported (All)
1
AUX (n) Bus Facing Loopback
AUX (n) Line Facing Loopback
Ethernet
Ethernet
Switch Access Failure
Configuration Not Supported (All)
V-2-38
Eclipse
n
Channel PRBS Test Active
Channel Loopback Active
n
Port Loopback Active
Port Monitoring Active
Direct Link Active
FAN
FAN
Fan Failure (FAN)
V-2-39
2. Eclipse
Portal Diagnostics
Portal Diagnostics
Eclipse.. 2-4
.
"" .
. ,
, ,
, .
System Controls,
,
.
2-4. Diagnostic
System Summary
System Summary - ,
Portal.
,
.
INU/INUe.
,
.
.
Alarms Plug-ins
.
Circuits Circuit Loopbacks.
. ( , IDU ES
IDU 300 20xV2)
V-2-40
Eclipse
Alarms
,
.
.
,
,
,
.
, RTC (
) ADC
(- ),
.
.
.
,
, ,
/.
Help for Alarm
() .
,
,
, ,
.
c Portal
HSX Helpset. ,
" Eclipse"
( ),
B
,
. ,
Demodulator Not Locked (
)
.
(
(Tx)),
,
. ,
,
.
V-2-41
2. Eclipse
Event Browser
,
/.
5000
( ,
).
/
.
, ,
,
.
, , ,
.
.
Help for Event
() .
,
,
, ,
.
c Portal
HSX Helpset.
V-2-42
Eclipse
History
Events
Browser Alarms:
G.806 , RSL,
.
,
. , ,
,
.
G.826
G.821
RSL
15-
15
; 24
.
Performance
G.826
, RSL,
,
BER, ODU
-48 .
ODU.
,
,
.
V-2-43
2. Eclipse
System Controls
,
AUX.
:
AUX
BER-
AIS
(Tx)
Parts
V-2-44
,
.
Eclipse
,
.
.
HSX Helpset,
,
.
pdf- "
Eclipse",
(,
"view history").
Eclipse,
. B. .
. B.
.
:
INU . 2-45
IDU . 2-49
INU
INU.
V-2-45
2. Eclipse
INU
Event System Restart
Unsupported Configuration
Event Log Activitiy Suspended
Event Log Activitiy Resumed
RAC
V-2-46
Eclipse
DAC
Event System Restart
Unsupported Configuration
Event Log Activitiy Suspended
Event Log Activitiy Resumed
AIS Transmitted
AIS Transmission Ceased
AUX
Event System Restart
Unsupported Configuration
Event Log Activitiy Suspended
Event Log Activitiy Resumed
Alarm Output 1 Activated
Alarm Output 1 Deactivated
Alarm Output 2 Activated
Alarm Output 2 Deactivated
Alarm Output 3 Activated
V-2-47
2. Eclipse
NPC
Event System Restart
Unsupported Configuration
Event Log Activitiy Suspended
Event Log Activitiy Resumed
DAC ES
Event System Restart
Event Log Activitiy Suspended
Event Log Activitiy Resumed
Traffic Alignment Error
Excessive Dropped Frames
Unsupported Configuration
Automatic Learning Disabled
Automatic Learning Enabled
DAC GE
Event System Restart
Event Log Activitiy Suspended
Event Log Activitiy Resumed
Traffic Alignment Error
Excessive Dropped Frames
Unsupported Configuration
Automatic Learning Disabled
Automatic Learning Enabled
DAC 155oM
Event System Restart
Event Log Activitiy Suspended
Event Log Activitiy Resumed
Traffic Alignment Error
V-2-48
Eclipse
FAN
Event System Restart
Unsupported Configuration
Event Log Activitiy Suspended
Event Log Activitiy Resumed
IDU
IDU.
IDU
Event System Restart
Portal User Logged On
Portal User Logged Off
Traffic Alignment Error
Terminal Accessed By Stratex Key
Software Reset
Software File Received
Software Changed
Automatic Learning Disabled
Configuration User Reverted
Configuration Changed
Watch Dog Expired
Power On
POST Failed
Generic Trap
Date / Time Changed
Low Memory
Event Action Created
Event Action Accepted
User Authentication Successful
V-2-49
2. Eclipse
IDU
Event System Restart
Unsupported Configuration
Event Log Activitiy Suspended
Event Log Activitiy Resumed
Event System Restart
V-2-50
Eclipse
Unsupported Configuration
Event Log Activitiy Suspended
Event Log Activitiy Resumed
AIS Transmitted
AIS Transmission Ceased
AUX
Event System Restart
Unsupported Configuration
Event Log Activitiy Suspended
Event Log Activitiy Resumed
Alarm Output 1 Activated
Alarm Output 1 Deactivated
Alarm Output 2 Activated
Alarm Output 2 Deactivated
Alarm Output 3 Activated
Alarm Output 3 Deactivated
Alarm Output 4 Activated
Alarm Output 4 Deactivated
FAN
Event System Restart
Unsupported Configuration
Event Log Activitiy Suspended
Event Log Activitiy Resumed
V-2-51
VI
A.
Eclipse NxE1/DS1 super PDH.
:
.A-2
.A-4
.A-7
.A-8
,
.A-22
.
, :
- Ethernet
- DAC 155oM
- -
, ,
:
- II, 3.
- IV,
, Harris Stratex Networks
:
- DAC ES Eclipse
- DAC GE Eclipse
- DAC 155oM Eclipse
- Eclipse
VI--1
. NxE1 NxDS1 (Super PDH)
Eclipse,
. .
.
Eclipse PDH 751
84xDS1.
,
. .
,
RAC Portal Protection
(East) (West) .
:
:
RAC, RAC ( ).
,
.
:
RAC, RAC ( ).
;
,
( )
,
.
,
,
wrapping ().
1 DS1, , ,
.
(pass-through),
(drop-and-inserted).
VI--2
Eclipse
.
drop-insert /.
,
RAC DAC ( RAC)
.
,
RAC / DAC
(RAC).
,
,
Error-Free
Timer ( ) Delay Ring Unwrap
Timer ( )
,
.
,
,
Eclipse.
, .
Eclipse "
Eclipse", G.
VI--3
. PDH- E1 DS1
.
, , .
, :
(INU INUe).
.
(- ).
INU/ INUe.
,
, .
, :
,
(drop-insert).
,
(pass-through) .
.A-1
c - (North-South).
.A-2
.A-1.
"-" "
" Excel
Eclipse, Harris
Stratex Networks Help Desk.
VI--4
Eclipse
A-1. "-"
VI--5
A-2. , .A-1
VI--6
Eclipse
. , :
,
.
(RAC, DAC 155oM)
INU/INUe
:
INU - .
1 2.
INUe - 1 4,
2 5, 3 6.
, DAC 16x,
INU/INUe,
(
).
Portal Configuration > Protection.
, ,
. ,
, , ,
.
Eclipse,
" Eclipse", III, "".
VI--7
Portal,
Eclipse. :
.A-8
.A-8
.A-9
.A-14
.A-16
.A-20
/ .A-21
Portal, ,
, :
Plug-ins (), Protection () Circuits ().
RAC, INU , INUe - .
DAC 155oM.
Compact Flash,
.
( ) RAC,
c 101 16xDS1.
, ,
" "
VI--8
Eclipse
RAC.
RAC/RAC
RAC .
Licensing
, IV, 4.
RAC RAC DAC 155oM
.
,
.
-
INU INUe. IV, 4,
" Eclipse".
VI--9
(Send)
RAC ,
.
:
Non-Protected () Partners,
(, DAC 16x), , ,
System Summary.
Protection
Protection () RAC
DAC 155oM ( ).
Type ID :
RING () ,
" " ( RAC),
" " (RAC) (DAC
155oM).
LINK ,
.
DATA DAC
155oM.
.A-3 Protection .
VI--10
Eclipse
LINK .
161 (
1xE1/DS1).
,
, -.
(standard) (sensitive).
(standard), (sensitive) (delayed).
, ,
.
10-6 BER .
.
.
VI--11
:
1. -,
.
2. (RAC / DAC 155oM),
:
. (West)
.
,
, .
(
-
Consequences).
, RAC,
Ring ID ( ).
3. , ,
Protect Protection Selection ( ).
-.
4. (wrap) (unwrap) .
. .A-3. (Standard)
(Sensitive) ,
(Error-free Timer)
(Delayed Ring Unwrap timer):
, .
.-124, II, 3.
10-6 BER .
/ 10-6 BER.
,
10-6
BER.
VI--12
Eclipse
(Error-free Timer)
, ,
. (
, ,
.
,
). 5
( ).
(Delay Ring Unwrap)
, , ,
, , ,
, Error-free Timer.
- , (Wrap)
(Unwrap) Standard.
- Delay Ring Unwrap (
) 1 . ,
,
Error-free Timer, Delay Ring Unwrap
.
System/Controls ,
.
Error-free Timer, Delay Ring Unwrap Timer. (
).
5. , ,
"Swap East with West" (
).
6. Send .
VI--13
Configuration > Plug-ins /
:
/
ATPC
( )
.A-4 Plug-ins .
""
" Eclipse", IV, 4.
, :
- ,
RING (RAC)
.
- .
. " >
Eclipse".
,
, ,
, (Tx High Tx
Low).
.
,
. ,
, ( )
.
(Online LED)
(Status LED) RAC.
, Portal
. (
Portal).
, RAC , , ,
RAC ( ).
, .
VI--14
Eclipse
A-4. Plug-Ins
Module - ,
.
( -)
.
Path Settings
, (Tx Power) ATPC
RAC ().
VI--15
Configuration > Circuits , -
(Traffic Circuits), -
(Auxiliary Circuits).
-
.
(Auxiliary)
Portal > .
Circuits, :
DAC RAC (
), .
.
, ,
( )
.
- ,
.
:
1. ,
.
2. - DAC / RAC,
.
3. (
) .
-
, , ,
/ .
-
, , , ,
/ .
.A-4.
VI--16
Eclipse
-
.A-5 - .
A-5. Circuits
1
2
3
4
5
,
Plug-ins.
(21)
- (Pt-to-Pt).
DATA 2.
(101)
.
, 161
, - .
VI--17
, DATA 2,
41, 121 .
Traffic Circuits ( ),
:
(East) (West) RAC 16xE1.
141,
21 -
.
4 DAC 16x (DATA 2)
/ . 101
.
16
, -.
4xE1 DATA 2
/, 121
.
- .
.
,
RAC DAC, DAC RAC.
-
/
- pass-through ring circuits.
:
VI--18
Eclipse
- To,
( ,
).
To > Port (
) .
, From To
,
.
, From 321,
To - DAC 16xE1, From To
161. ,
-,
Port, .
2. Apply ().
port-to-port connections,
.
Apply
.
,
.
,
From To,
, Apply.
Apply .
3. , Send
.
:
VI--19
1. Port-port connections
.
2. , From To
.
Port , Apply.
,
, Port. ,
, .
.
3. Send .
,
,
(pass through ring circuits),
Port-port connections .
Configuration > Networking
IP NMS.
, RIP
OSPF. .
IP-
(Single IP Addressing), ,
, .
, ,
IP-:
VI--20
Eclipse
10.16.1.1
255.255.255.0
Link 3
Link 1
INU
A
INU
F
10.16.6.1
255.255.255.0
Link 2
Link 1
10.16.2.1
255.255.255.0
INU
B
Link 2
Link 2
Link 1
Link 1
INU
Link 2
INU
E
10.16.5.1
255.255.255.0
Link 2
Link 1
Link 2
INU
D
10.16.3.1
255.255.255.0
Link 1
10.16.4.1
255.255.255.0
/
Configuration > Date/Time
Eclipse. IV, 12.
VI--21
.
,
:
NMS
,
. ,
:
.A-4
,
c
,
Portal ( Ethernet NMS) .
:
.A-22
.A-23
.A-24
.A-24
Portal . (
IP- )
.
. ,
.
, , :
VI--22
Eclipse
IP- NMS .
,
.
System
Summary .
, :
NMS .
, ,
Portal. "
", 4, 2.
,
.
,
, .
Portal RAC
RING . RING
( ),
IP-
().
,
:
1. , System Summary .
2. Diagnostics > Performance Start All
.
RAC, RAC Plug-ins.
, (Detected Tx
Power) (RSL)
, .
, 48
.
RAC
G.826
.
,
VI--23
,
BER-
.
1. Configuration > Circuits > Traffic Circuits Port
to Port Connections
.
2. DAC
BER-.
BER-.
BER- ,
- .
BER- ,
.
3. BER- ( ),
.
BER- ,
G.826 Performance
.
, ,
DAC, BER-
G.826.
.
,
.
, G.826
,
BER- DAC /
RAC TDM-.
.
("")
.
(RAC/
ODU) (DAC 155oM) :
Eclipse
.A-25
(DAC 155oM) .A-25
.A-26
.A-26
, :
(Tx path failure):
(Tx synthesizer not locked)
(Tx transceiver
failure)
(Tx power failure)
ODU (Tx ODU IF
synthesizer not locked)
RAC (Tx RAC IF
synthesizer not locked)
(Modulator not locked)
(Rx path failure):
ODU (ODU Tx cable IF
synthesizer not locked)
10-6 BER ( )
RAC (RAC plug-in is missing)
RAC (RAC software
load failure)
(DAC 155oM)
, :
SDH/SONET (Loss of SDH/SONET frame)
DAC 155oM (DAC 155oM plug-in is missing)
DAC 155oM (DAC
155oM software load failure)
VI--25
RAC DAC 155oM ( RAC/DAC
" ").
:
(,
) 100 .
,
,
(Error-Free Timer) ( 5
), (Delay
Ring Unwrap Timer),
.
, 100
.
Error-free Timer Protection configuration
,
. ,
,
, ,
. ,
.
: 10 , 1, 5 10 .
5 ( ).
Delay Ring Unwrap
Protection ,
, ,
, , ,
. 1 ;
, ,
, Delay Ring Unwrap
.
System/Controls ,
. Error-free Timer,
Delay Ring Unwrap Timer. ( ).
VI--26
Eclipse
:
Tx mute
Diagnostics > System Controls, RAC.
RAC .
,
,
ODU RAC. /
, , RAC .
:
1. , ,
.
Portal.
2. BER-
.
3. (East) RAC RAC
:
BER-
.
(
, ,
).
4. ( RAC ).
(Status LED)
(Online LED) RAC.
, ,
,
,
.
,
(nline LED) .
(nline LED) ,
.
System/Controls screen.
, :
VI--27
,
,
.
BER- ,
("").
- (
, ,
).
5. 1 4 (West) RAC.
Tx mute ( ) RAC
,
, ,
.
VI--28
B.
Eclipse
Eclipse .
,
Portal Alarms.
,
, , .
,
Eclipse (
). .B-1
, .
. B-1.
Eclipse
Eclipse:
NCC/IDU
RAC/
DAC/
AUX
NPC
FAN
DAC ES
IDU ES
DAC GE
DAC 155oM
VI--1
,
. , RAC RAC 30 RAC 10
80%,
.
Alarms ,
.
.
(
), (All). :
FPGA Software Load Failure
EEPROM Failure
Configuration Not Supported
Software/Hardware Incompatible.
Eclipse .-1,
Portal
.
Helpset,
"
". Portal
V, 2.
NCC/IDU
FPGA Software Load Failure (All)
()
(FPGA). .
1.
, : , ,
VI--2
Eclipse
.
2. ,
.
, .
3.
, .
,
.
4. , /IDU.
FPGA :
.
,
FPGA.
RAC, DAC AUX .
, FPGA
/ RAC/DAC.
RAM Failure
.
.
1. , ,
.
, .
2. ( , , ).
3. , NCC/IDU.
VI--3
- .
( , , ).
, NCC/IDU, ,
- -.
-
.
.
- /
.
/ -.
( , , ).
, NCC/IDU.
-
.
VI--4
Eclipse
1. ,
, .
, /
.
2. ( , , ).
, NCC/IDU.
NCC
NCC/IDU.
RTC Failure
(RTC).
.
1. , ,
. , /
.
2. ,
NCC/IDU, Portal
Date/Time. , Portal Events Browser
- /. ,
RTC.
, ,
/.
, NCC/IDU.
RTC /.
VI--5
( , , ).
, NCC/IDU.
,
.
, .
/ .
NCC/IDU,
TDM- FPGA.
, NCC TDM Clock Failure,
, NPC.
N , TDM-
NPC, .
1. , ,
. , /
.
2. NCC/IDU.
VI--6
Eclipse
1. , ,
. , /
.
2. NCC/IDU.
1. , ,
. , /
.
2. NCC/IDU.
1. , ,
. ,
.
2. NCC.
VI--7
48 ,
-40,5 -60 .
3. 48
. ,
NCC/IDU.
-48 Portal Performance.
4. NCC/IDU,
, , .
, /
.
5. NCC/IDU ( ), NCC/
IDU.
-40,5 -60 .
1. , ,
. , /
.
2. NCC/IDU.
VI--8
Eclipse
1. , ,
. ,
.
2. NCC.
Temperature
NCC/IDU .
.
1. FAN ( ).
2. .
3. .
1. (LED) FAN .
, , ,
-
FAN.
, , ,
,
.
2. INU/INUe/IDU,
+ 55 (131 F). ,
.
3. , . ,
, INU/INUe
,
50 (2").
4. , ,
,
. NCC/IDU.
VI--9
, .
.
NCC.
FAN, ,
.
FAN.
.
.
INU ,
, ,
-.
, ;
.
FAN .
FAN, .
VI--10
Eclipse
NCC, ,
. , NCC.
,
NPC TDM- NCC.
, ,
TDM- NCC NPC.
. ,
10 .
NCC
TDM- NPC.
, NCC,
Portal System Controls.
.
TDM- NPC,
NCC. ,
NCC, NPC.
NPC NCC,
.
Configuration Corrupt
.
.
1. ,
( , ,
VI--11
).
2. ,
, .
, .
3. ,
Flash Card Failure ( -), NCC/
IDU.
.
.
1. , ,
DAC 16x, AUX, RAC ,
DAC 155o.
2. RAC/ODU IDU/ODU.
1. ,
. , ,
Portal Layout.
2. , RAC/ODU IDU/ODU
. RAC 30 RAC 40
ODU 300. RAC 10 IDU - ODU 100.
, :
VI--12
Eclipse
, ,
, .
ODU, ,
, /IDU.
,
Eclipse.
Portal Date/Time.
1. , .
2. , Portal
Layout.
VI--13
,
.
1. , .
2. , Portal Layout,
.
TDM- NCC
Portal System Controls.
, .
NPC
.
Circuit Loopback
.
.
, Circuit Loopbacks.
VI--14
Eclipse
NMS.
NMS.
.
AUX.
.
DAC.
VI--15
/ .
.
DAC.
RAC/
Fuse Blown
RAC, -48 .
ODU. .
1. ODU.
2. ( ) ODU.
1. ODU RAC
,
ODU.
0,3 .
2. ,
, ODU
ODU.
3.
RAC;
.
VI--16
Eclipse
ODU N-
0,3 .
1. , ,
. ,
.
2. , ,
. , .
EEPROM
.
:
, (
, , ).
, RAC.
,
, NCC. ,
, NCC.
VI--17
,
.
, .
Modulator Failure
. .
Modulator Not Locked.
, RAC.
, Detected Tx Power (
) Portal Performance ,
,
( ). RAC ,
, .
, RAC.
,
Modulator Not Locked, (Tx).
(Tx) Portal Performance.
:
, Demodulator Not Locked
, ( , ,
).
VI--18
Eclipse
,
, , NCC
. , ,
NCC.
,
.
, .
:
, (
, , ).
, RAC10/IDU.
,
, NCC/IDU. ,
, NCC/IDU.
,
.
,
.
VI--19
1. , ,
. , /
.
2. ( , , ).
, ODU.
ODU
NCC/IDU. RSL,
Detected TX Power ( ),
ODU.
1.
, ( ),
48 ., .
2. ,
.
, .
3.
, .
,
.
4. , ODU.
FPGA :
INU/INUe.
RAC, DAC AUX INU/INUe
.
VI--20
Eclipse
,
FPGA.
FPGA ODU
/ .
:
, ( ,
, ). ,
ODU.
ODU,
ODU,
ODU NCC/IDU ODU.
ODU, NCC/
IDU. NCC/IDU.
, NCC/IDU ODU.
,
.
c , .
ODU .
VI--21
:
, Rx path failure
( )
,
( , , ).
, ODU.
ODU,
ODU,
ODU, ODU
NCC/IDU ODU. , NCC/IDU
ODU.
,
.
, .
:
,
(Tx) ,
( , ,
). , ODU.
ODU,
ODU,
ODU, ODU
NCC/IDU ODU.
ODU, NCC/
IDU. , ,
NCC/IDU.
, NCC/IDU ODU.
VI--22
Eclipse
NCO .
,
. NCO
, .
:
,
(Tx)
,
( , , ).
, ODU.
ODU,
ODU,
ODU, ODU
NCC/IDU ODU.
ODU, NCC/
IDU. , ,
NCC/IDU.
, NCC/IDU ODU.
,
.
, .
VI--23
:
, Rx path failure
( )
, c
( , , ).
, ODU.
ODU,
ODU,
ODU, ODU
NCC/IDU ODU.
ODU, NCC/
IDU. , ,
NCC/IDU.
, NCC/IDU ODU.
NCO ( ODU 100 RAC 10).
,
. NCO
, .
48 ODU ,
-40,5 -60 .
1. , ,
. ,
NCC -48V (-48 NCC) ODU -48V Supply
( -48 ODU). ,
.
VI--24
Eclipse
48 . ,
-40,5 -60 . ,
ODU
.
1. , ,
. ,
NCC/IDU -48V, , , RAC -48V Supply.
,
.
2. ODU -48 Portal Performance,
,
.
-48 Eclipse , (, Eclipse,
RAC -48V Supply), , ODU
ODU.
3. , ODU,
.
ODU,
. .
9913 0,01
(0,003 ). , 100
1 ,
, .
4. ,
ODU , /
ODU. ODU.
VI--25
:
ODU RAC/IDU ODU
.
RAC, .
Harris Stratex .
IF Temperature
/ .
.
1. ODU , ,
.
2. .
55oC (131oF),
( ).
1. , ODU:
Power Detector Temperature ( )
Transceiver RX Temperature (
). PA Current.
2. Portal Performance,
(ODU Temperature) (Detected Tx
Power) ODU. 90C,
(Tx).
,
.
/ ODU,
ODU.
, ODU.
ODU.
,
, ,
. ODU.
3. ,
Portal Events Browser History,
VI--26
Eclipse
. , ODU
.
/ . /IF
ODU.
ODU 10oC
ODU, ,
45oC (113oF),
.
2
( 1 ) (Tx)
Plug-ins RAC/ ATPC. ATPC
,
(Tx).
1. ODU , ,
.
2. .
55oC (131oF),
( ).
1. , ODU: IF
Temperature ( ) Transceiver RX Temperature
( ).
PA Current.
2. Portal Performance,
(ODU Temperature) (Detected Tx
Power) ODU. 90C,
(Tx).
,
.
VI--27
/ ODU,
ODU.
, ODU.
ODU.
,
, ,
. ODU.
3. ,
Portal Events Browser History,
. , ODU
.
PA ( ) .
Portal Performance ODU.
ODU 10oC
ODU, ,
45oC (113oF),
.
2
( 1 ) (Tx)
Plug-ins RAC ATPC. ATPC ,
(Tx).
Transceiver RX Temperature
(Rx) .
.
1. ODU , ,
.
2. ODU.
1. , ODU:
Power Detector ( ) IF ().
2. Portal Performance,
VI--28
Eclipse
.
55oC (131oF),
( ).
2
( 1 ) (Tx)
Plug-ins RAC ATPC. ATPC ,
(Tx).
1. ,
ODU, ,
VI--29
PPP (
"-") NCC ODU.
ODU,
(watchdog),
5 .
1. :
Demodulator Not Locked Rx path failure,
,
(Rx),
(Tx) .
Demodulator Not Locked (
),
,
,
NMS, /
.
.
2. , ,
ODU NMS:
NMS ,
.
AUX,
() Auxiliary Channel Clock Fail. ,
.
ODU RAC/,
VI--30
Eclipse
,
.
,
. , NCC/
IDU. , , , ODU
RAC/ (Tx)
(Rx).
Remote Communications Failure ,
.
, NMS,
/ .
NCC/IDU.
Portal System Controls (IF Loopback).
TX Power Mute
.
.
Portal System Controls (Tx mute).
Tx mute
(
).
VI--31
ATPC Disabled
ATPC .
.
ATPC Portal System Controls.
ATPC Portal System Controls.
TX Manual Lock
.
.
(locked)
.
, .
RX Manual Lock
.
.
RAC
Portal System Controls (
TDM-).
, .
VI--32
Eclipse
Portal System Controls
(Digital Loopback).
, ,
Detected Tx Power ( ) Portal
Performance. ODU.
,
.
.
Transceiver TX Failure
.
.
, Detected Tx
Power Portal Performance. ODU.
VI--33
, ,
Detected Tx Power ( ) Portal
Performance. ODU.
,
.
Detected Tx Power Portal Performance,
. Modulator Not Locked
ODU.
( , , ).
:
RAC 30 RAC 40, RAC.
RAC10/IDU, ODU (ODU 100).
Modulator
Failure ( ) (RAC 30/40) Cable Demodulator
Failure ( ) (ODU 100),
, .
(Tx)
.
RAC10/, ODU Cable
Demodulator Not Locked, ,
Modulator Not locked.
VI--34
Eclipse
RAC.
,
ODU .
,
BER. Performance
.
ODU RAC
10 , RAC.
ODU Tx Synth Not Locked , ,
10 RAC.
ODU.
ODU
.
(BER, ES, SES, ESR SESR)
.
VI--35
.
Modulator Not
Locked, , ,
.
( , , ).
Cable
Demodulator Failure ( ).
, ,
.
ODU.
, ,
ODU.
ODU.
VI--36
Eclipse
.
.
.
ODU.
,
ODU .
,
BER. Performance
.
(RAC/
).
3.
.
RAC 30/40,
Rx Synthesiser ( )
Rx IF Synthesiser ( ).
VI--37
RAC 10 / IDU,
Rx Synthesiser ( )
Tuner ( ).
4. :
RAC 30/40,
, ,
, ODU, ,
ODU Cable Unplugged ( ODU).
RAC 10 / IDU, ,
.
5.
, ,
.
-
. ,
- ODU,
.
RAC 30/40, RAC. RAC 10 /
IDU, ODU.
.
1. :
- ODU Cable Modulator Not Locked
- Demodulator Not Locked
- Tuner Not Locked
- RX Synthesiser Not Locked
Demodulator Not Locked ODU
Cable Modulator Not Locked,
VI--38
Eclipse
.
, RSL Portal
Performance.
RX Synthesiser Not Locked Tuner Not Locked,
ODU Cable Modulator Not Locked ,
ODU.
RAC/
IDU Cable Deomodulator Not Locked,
RAC 10 / IDU.
2.
, ( ,
, ):
RAC/IDU Cable Demodulator Not Locked
,
(
), RAC/IDU.
ODU
Component Failure, RX Synthesiser Not Locked, Tuner Not
Locked, ODU Cable Modulator Not Locked, ODU.
ODU, , ,
.
( , , ).
, ODU.
Tuner ( ) I/Q.
.
:
Demodulator Not Locked, ODU Cable Modulator Not Locked, RAC Cable
VI--39
:
- Demodulator Not Locked
- Tuner Not Locked
- RX Synthesiser Not Locked
Demodulator Not Locked ODU
Cable Modulator Not Locked,
.
, RSL Portal
Performance.
RX Synthesiser Not Locked Tuner Not Locked,
ODU Cable Modulator Not Locked ,
ODU; ( ,
, ). ,
ODU.
ODU .
(OnLine LED) RAC,
.
VI--40
Eclipse
(),
ODU, -48 .
ODU. ODU,
RAC -48V Supply.
(),
ODU; . Detected
Tx Power RSL Portal Performance. ,
. ODU.
ODU Cable Unplugged
ODU.
, -48 . ODU
ODU.
, ODU
. ,
; ODU .
RAC, , .
RAC.
, .
1. , ,
(LOS) -
:
VI--41
RSL Below Threshold (RSL ).
Demodulator
Not Locked
,
,
,
.
2. ESR Threshold Exceeded
,
,
G.826 RSL Portal
Performance:
RSL G.826,
, , ,
- ,
.
BER.
ESR
, RSL , ,
. Portal History Event Browser,
ESR,
, ,
G.826 .
ES ( ) -
, , .
ESR ( ) - ES
. Eclipse, 60
, ESR
20%.
, .
VI--42
Eclipse
1. , ,
(LOS) -
:
SESR Threshold.
Demodulator
Not Locked
,
,
,
.
2. SESR
Threshold Exceeded
G.826, G.826 RSL ,
Portal Performance:
RSL G.826,
, , ,
- ,
.
BER.
ESR SESR
, RSL , ,
. Portal History Event Browser,
ESR,
, ,
G.826 .
SESR
ESR BER.
- ,
, , 30% , ,
. 10 SES
.
SESR - SES
. Eclipse,
60 ,
10%.
VI--43
- , .
.
1. , ,
:
BER Threshold.
Demodulator
Not Locked
,
,
,
.
2. BER
Threshold Exceeded,
G.826, G.826 RSL
, Portal Performance:
RSL G.826,
, , ,
- ,
.
.
RSL ( ),
, ,
.
, , ,
, .
BER Threshold
, RSL , ,
,
.
- LINK/RAC
VI--44
Eclipse
. ,
, Event Browser
.
- ,
G.826,
. Portal History Event
Browser BER.
3. BER c RSL,
,
RAC ODU.
Detected Forward Power (
)
.
10-3 BER
10-6 BER.
13
. - 11
. ,
.
,
.
,
BER.
.
- , .
.
1. , ,
VI--45
:
BER Threshold.
Demodulator
Not Locked
,
,
,
.
2. BER
Threshold Exceeded,
G.826, G.826 RSL
, Portal Performance:
RSL G.826,
, , ,
- ,
.
.
RSL ( ),
, ,
.
, , ,
, .
BER Threshold
, RSL , ,
,
.
- LINK/RAC
. ,
, Event Browser
.
- ,
G.826,
. Portal History Event
Browser BER.
3. BER c RSL,
,
RAC ODU.
Detected Forward Power (
)
.
VI--46
Eclipse
13
. - 11
. ,
.
,
.
,
BER.
.
, .
.
RAC 40.
ODU PA Current
(PA) ODU .
.
ODU.
- PA,
,
ODU /
(Forward Power).
,
VI--47
ES BER
.
1. .
.
RSL BER; Portal History
Event Browser .
2. .
, ,
ODU, RAC NCC.
, .
/.
/ .
DAC
LIU Failure
LIU ( ).
.
VI--48
Eclipse
Eclipse, DAC ,
. , DAC.
Eclipse, ( ,
, ). ,
IDU.
DAC/ , LIU
/DS, / ,
.
1. , ,
. ,
.
2. DAC.
FPGA.
() AIS
,
Portal System Controls. AIS
VI--49
, AIS.
AIS ,
, ,
AIS-,
, .
AIS
(
) ,
,
(, ).
E1, DS1, E3, DS3, AIS
.
STM1/OC3 AIS
PRBS15 (15- ).
AIS
.
( TDM-),
Portal System Controls.
E1/DS1
AIS /
.
VI--50
Eclipse
,
Portal System Controls.
,
TDM- / .
BER- .
215-1-
(PRBS).
BER .
.
:
) PRBS
b) PRBS
.
VI--51
TX Manual Lock
RAC.
.
RAC . System/Controls
() (lock(s)).
().
RX Manual Lock
.
.
RAC . System/Controls
() (lock(s)).
().
Trib n LOS
(LOS)
. .
,
.
1.
,
.
2. .
3. . ,
.
4. ,
VI--52
Eclipse
BER-.
,
.
, DAC/IDU.
.
E1/DS1 AIS
TDM-/,
commissioned (
) Plug-ins Portal.
DAC, , .
DAC.
. ,
, "
" (commissioned).
Portal
commissioned/uncommissioned ( /
), .
VI--53
,
.
Plug-ins; -
Circuits.
Trib n AIS
AIS.
.
AIS -
,
.
AIS,
, .
AUX
Alarm Input (n)
AUX, 'n' 1 6
Eclipse, 1 2 .
.
AUX.
,
AUX.
VI--54
Eclipse
,
.
, AUX
,
.
,
.
, ,
Plug-ins AUX
.
AUX DCE ( ).
, DCE
( ), DTE ( ),
,
( ).
,
DCE ,
. DE ,
DCE,
, DTE .
AUX
DTE (, ), AUX
, - .
AUX Eclipse
, () DCE, ,
DCE
. DCE AUX
Eclipse, DCE, , .
DCE, .
VI--55
,
(Tx) .
,
(Tx)
() .
DCE DTE .
DCE DCE -.
(Tx) (Rx) AUX
. .
Portal System Controls
.
Portal System Controls
.
VI--56
Eclipse
NPC
Clock Generator Failure (NPC)
.
.
1. , ,
. ,
.
2. NPC.
FPGA.
1. NCC (
), NPC. .
2. NCC ,
, ,
. ,
.
( ),
NPC , NCC
.
VI--57
() NCC.
NPC, NCC 3 ,
. NPC,
TDM-,
.
1. NCC (
), NPC. .
2. NCC ,
, ,
. ,
.
( ),
NPC , NCC
.
() NCC.
NPC, NCC 3 ,
. NPC,
TDM-,
.
VI--58
Eclipse
1. NCC (
), NPC. .
2. NCC ,
, ,
. ,
.
( ),
NPC , NCC
.
() NCC.
NPC, NCC 3 ,
. NPC,
TDM-,
.
48 NPC ,
-40,5 -60 .
3. NCC -48 Vdc -48
ODU Portal Performance.
,
. .
,
NPC. NPC.
-40,5 -60 .
NCC , NPC
.
VI--59
NPC, ,
. , NPC.
NCC , NPC
.
TDM- NPC
Portal System Controls.
, .
DAC ES
Switch Access Failure
Ethernet.
.
VI--60
Eclipse
Transport Channel Failure Port
Failure.
, DAC.
( ), DAC
. , DAC ES,
DAC c
,
.
BER- .
(PRBS).
BER .
DAC ES DAC
GE. :
) PRBS
b) PRBS
DAC ES / DAC GE
VI--61
( TDM-),
Portal System Controls.
DAC ES / DAC GE /
( TDM-),
Portal System Controls.
DAC ES / DAC GE,
Portal System/Controls.
,
.
VI--62
Eclipse
- DAC ES / DAC GE,
Portal System/Controls.
:
) 1 1
b) 1 1 2 2.
, ,
Plug-ins DAC ES / DAC GE, .
, , .
/
.
1. DAC ES / DAC GE.
,
, , ,
. ,
, DAC ES / DAC GE.
,
,
DAC ES / DAC GE
RAC/ODU, .
,
,
.
2. - DAC ES / DAC GE
VI--63
PRBS.
.
,
PRBS - .
3.
,
, DAC ES / DAC GE, .
" ".
DAC ES / DAC GE,
;
DAC ES / DAC GE.
Ethernet-, , ,
Dropped Frame ( ),
.
Ethernet.
Ethernet
.
, RJ-45
NMS Ethernet NCC.
NMS ,
.
(
Ethernet-,
Ethernet-), DAC ES / DAC GE.
Enabled () Plug-ins DAC ES / DAC
VI--64
Eclipse
GE ,
. , ,
.
(
E1/DS1,
).
(Tx) (Rx) Portal System/
Controls, ,
, ,
Plug-ins DAC ES DAC GE, ,
(
).
DAC ES DAC GE,
. , , , ,
,
.
, ,
,
.
DAC GE
ICPU Failure
.
.
VI--65
DAC GE, , .
DAC GE.
( ).
DAC GE 3.1 .
3.4 , RWPR
.
DAC GE.
Link Down
DAC GE .
.
, , .
/
.
(RAC, DAC
155oM), ,
.
DAC GE.
Link Degraded
DAC GE .
.
Eclipse
, ,
.
/ .
(RAC, DAC
155oM),
.
DAC GE.
DAC 155oM
PMC TEMAP Access Failure
IC.
.
DAC 155oM, , .
DAC 155oM.
DAC 155oM, , .
DAC 155oM.
VI--67
Portal
System/Controls.
Portal
System/Controls.
().
RDI In
/ .
.
.
DAC 155oM .
/ .
K2[6..8] = "110" 3- .
() /
.
VI--68
Eclipse
AIS In
(AIS) .
.
.
,
( ).
, .
, , Signal Fail
BER LOS.
, , ,
, .
, BER
.
10-6, 10-7 10-8. B2 .
, .
VI--69
,
.
B2 .
LOS
(LOS) .
.
, .
/ .
,
, BER 1 10-3. ,
, LOS.
LOF
(LOF) .
.
, .
/ .
VI--70
Eclipse
, OOF, 3 c.
, - 3
.
OOF
(OOF) .
.
.
/ .
, ( 4-5)
( A1/A2).
625 - 250 ,
.
Container x AIS
AIS . .
" " H1
H2 .
Container x LOP
(LOP) .
.
VI--71
,
/ , ,
LOS, OOF Signal Degrade/Fail BER.
, ,
,
. (
, ), /
.
LOP , STS-1
8 , 8
NDF.
/ .
Container x LOM
(LOM) .
.
,
, , LOS
LOP .
, DAC 155oM.
H4
8 . 4-
8 .
Container x RDI
/ (RDI) .
VI--72
Eclipse
,
, RDI-in.
DAC 155oM.
() LOS, LOF AIS
.
Container x RPSLM
(RPSLM)
. 2 C2.
.
DAC 155oM
.
:
RDI (V5[8] 1 5 )
AIS (V5[1..3] 1)
PSLM ( V5[5..7] V5[5..7])
LOP ( 8 8
NDF)
VI--73
RFI (v5[4] 1 5 )
DAC
155oM .
, ,
.
.
, DAC 155oM.
DAC 155oM.
FAN
Fan Failure (FAN)
FAN.
.
FAN, ,
.
FAN.
.
.
INU ,
, ,
-.
, ;
.
VI--74
Eclipse
AIS Transmission Ceased
AIS
.
.
AIS Transmitted
AIS .
.
VI--75
ATPC Active
ATPC .
ATPC Inactive
ATPC .
VI--76
Eclipse
Configuration Changed
.
VI--77
Generic Trap
,
, SNMP (RFC 1157) SMIv2 (RFC
2578).
.
License Entered
.
.
Low Memory
.
POST Failed
(POST)
. .
Power On
INU . ,
"
".
VI--78
Eclipse
Protection Switch
.
.
RAC DAC.
Software Changed
, ,
.
VI--79
Software Reset
Portal SNMP.
Unsupported Configuration
,
.
.
VI--80
Eclipse
VI--81
C.
Eclipse
2005 .
Harris Stratex Networks .
:
.C-1
.C-2
RAC/IDU .C-2
INU, INUe IDU .C-9
DAC, IDU .C-14
.C-19
/ Eclipse
( : 857-000004-001), :
/
Eclipse
Eclipse
, Portal
Eclipse Portal
VI--1
Eclipse
PDF-
HSX Help
web-
Eclipse, ProVision,
,
VoIP.
V.24 Eclipse
Excel
Eclipse
Excel
Super-PDH Eclipse
Eclipse :
PDF.
Eclipse.
. : 260-668066-002.
web- HSX Help. HSX Help
Eclipse.
RAC/IDU
:
RAC .C-3
RAC 40 .C-3
IDU .C-4
RAC/IDU ODU .C-4
VI--2
Eclipse
.C-5
ODU .C-6
.C-6
RAC
RAC,
.
RAC
RAC 10
RAC 30
RAC 3X
RAC, SMA N -, 3
037-579122-001
RAC 40
RAC, SMA N -, 3
037-579122-001
RAC 40,
, 35
037-579123-001
, RAC 40,
,
INU.
RAC 40
RAC 40
037-579186-001
037-579266-001
037-579267-001
037-579286-001
1 108 , 1 168
RAC 40 INU ,
RAC 40, INU - INU
2 108
RAC 40 INU,
RAC 40, INUe - INUe
2 168
RAC 40 INUe,
RAC 40, INUe - INUe
2 254
RAC 40 INUe,
VI--3
RAC 40
PB05-062.
IDU
IDU, N- RA N - F, 1
037-579181-001
-
1
RAC/IDU ODU
IDU ODU 9913
Times LMR400.
9913 RAC/IDU ODU
ODU, 9913, / , 50
037-579106-001
ODU, 9913, / , 76
037-579109-001
037-579107-001
037-579108-001
, ,
9913
50
N- ""
800-600202-001
Andrews
242948
Harger
HA3-213T
, (50 )
40417
221213
086-523241-001
50 :
037-579259-001
037-579260-001
037-579261-001
VI--4
Eclipse
, ,
LMR500
50
N- ""
400APNM-C
Andrews
242948
Harger
HA3-213T
, (50 )
40417
221213
086-523241-001
50 :
LMR400, C2FCP 9913 .
840-600204-165
840-600204-250
840-600204-500
840-600204-AAA
N- "" 9913
800-600202-001
N- "" 9913
840-900410-001
N -, Tessco 78884
840-600203-001
Andrews 9913
242948
VI--5
ODU
ODU,
:
ODU
, 2
037-579130-001
N-
350-000001-001
, 1 Oz Sachet, DC-4
011-300000-001
, 179-530017-001,
BGXZ .
, 179-530016-001 9913.
BR400C 103-0403A-B.
9913
, 9913,
INU/IDU
179-530016-001
, 9913,
INU/IDU ODU
179-530017-001
( :179-530017-001) :
VI--6
BGXZ Polyphaser
BGXZ-60NFNM-AS
N- 9913, RF
Industries RFN-1006-3I
840-600202-001
840-900410-001
Harger
HA3-213T
BGXZ,
2
086-523239-001
BGXZ ODU
Eclipse MKII
086-523238-001
086-523242-001
Eclipse
, 36
086-523240-001
-
2
( :179-530016-001) :
BGXZ Polyphaser
BGXZ-60NFNM-AS
N- , RF Industries
RFN-1006-3I
840-600202-001
840-900410-001
Harger
HA3-213T
BGXZ,
2
086-523239-001
BGXZ ODU
Eclipse MKII
086-523238-001
086-523242-001
, 36
086-523240-001
179-530016-001 179-530017-001:
BGXZ Polyphaser
BGXZ-60NFNM-AS
N- , RF Industries
RFN-1006-3I
840-600202-001
840-900410-001
Harger
HA3-213T
BGXZ,
2
086-523239-001
BGXZ ODU
Eclipse MKII
086-523238-001
VI--7
VI--8
, 36
086-523240-001
-
1
Eclipse
037-502516-001
037-502517-001
037-579124-001
037-579125-001
037-579126-001
037-579127-001
WPE010-09V3
- IDU 16 ( )
EFC-10002
- INU ( )
EZE-00001
- INU ( )
EZE-00001
037-579100-003
, 2W2C, , 12 AWG, ,
3
037-579102-001
, NMS EOW
VI--9
, 2W2C, , 12 AWG, ,
5
037-579103-001
, 5 A, , 5X20MM (IDU)
027-380500-002
027-386007-001
027-386009-001
IDU,
:
IDU
857-000004-001
IDU Eclipse
179-530015-001
, 2W2C, ,
12 AWG, , 5
037-579103-001
25A 3AB .
()
027-386009-001
037-502516-001
950-500330-001
SCR,12-24 X 3/4,SS,PHIL,P/H
006-301412-024
, SS,SLW,#12
006-311412-001
IDU,
VI--10
Eclipse
:
IDU
857-000004-001
IDU Eclipse
179-530015-001
VI--11
SCR,12-24 X 3/4,SS,PHIL,P/H
006-301412-024
, SS,SLW,#12
006-311412-001
, 2W2C, ,
12 AWG, , 5
037-579103-001
, 5,
, 5X20MM
027-380500-002
037-502516-001
N-, Amphenol
82-64 RFX
350-000001-001
IDU
AUX
037-579112-001
037-579113-001
037-579118-001
037-579119-001
037-579177-001
037-579178-001
VI--12
Eclipse
IDU
IDU 1+1,
NMS.
1+1 , 1+1 - .
037-579279-001
037-579280-001
. PB05-027 .
Y- IDU
IDU 1+1
Y- . Y-
. Y-
IDU.
037-579268-010
037-579269-030
037-579274-030
VI--13
DAC, IDU
:
E1/DS1 .C-14
E3/DS3 (Slim Line BNC) .C-15
STM1/OC3 (SC, ) .C-16
STM1/OC3 (LC, ) .C-17
STM1/OC3 (BNC) .C-19
Ethernet RJ45 .C-19
E1/DS1
8 .
DAC 16x. DAC 16x
RJ21.
1713115-2
1713115-3
1713115-4
1713124-2
1713124-3
1713124-4
1713123-2
RJ21 BNC
RJ21
RJ21 RJ45
VI--14
Eclipse
1713123-3
1713554-2
1713554-3
1713723-1
1713723-2
RJ21 RJ45 1
RJ21 RJ21
1. DAC/IDU .
,
., Slimline BNC . BNC, 2
1-1700143-7
,
., Slimline BNC . BNC, 5
1-1700143-8
,
., Slimline BNC Slimline BNC, 2
2-1700143-8
,
., Slimline BNC Slimline BNC, 5
2-1700143-9
076-431038-001
/
DAC.
VI--15
STM1/OC3 (SC, )
.
DAC 155o DAC 2x155o:
, 3 , SM, SC-SC
037-579193-001
, 3 , SM, SC-SC
037-579194-001
, 3 , SM, SC-SC
037-579195-001
, 3 , SM, FC-SC
037-579190-001
, 5 , SM, FC-SC
037-579191-001
, 10 , SM, FC-SC
037-579192-001
2 SC-SC FC
037-579196-001
2 SC-SC LC
037-579197-001
4 SC-SC LC
037-579200-001
2 SC-SC SC
037-579198-001
4 SC-SC SC
037-579202-001
2 SC-SC ST
037-579199-001
4 SC-SC ST
037-579201-001
037-579203-001
037-579204-001
037-579205-001
037-579206-001
037-579207-001
037-579208-001
SC SC
SC FC
2 x SC 1
SC2
VI--16
Eclipse
037-579209-001
037-579210-001
037-579211-001
1.
2.
DAC.
,
.
STM1/OC3 (LC, )
.
DAC155oM DAC GE:
LC LC
, 3 , SM, LC LC
037-579131-001
, 5 , SM, LC LC
037-579132-001
, 10 , SM, LC LC
037-579133-001
, 3 , SM, LC FC
037-579134-001
, 5 , SM, LC FC
037-579135-001
, 10 , SM, LC FC
037-579136-001
, 3 , SM, LC SC
037-579137-001
, 5 , SM, LC SC
037-579138-001
, 10 , SM, LC SC
037-579139-001
037-579140-001
LC FC
LC SC
LC ST
, 3 , SM, LC ST
2 x LC 1
VI--17
2 LC-LC FC
037-579141-001
4 LC-LC FC
037-579145-001
2 LC-LC SC
037-579142-001
4 LC-LC SC
037-579146-001
2 LC-LC LC
037-579143-001
4 LC-LC LC
037-579147-001
2 LC-LC ST
037-579144-001
4 LC-LC ST
037-579148-001
, 3 , LC, 3DB
037-579149-001
, 5 , LC, 3DB
037-579150-001
, 10 , LC, 3DB
037-579151-001
, 3 , LC, 6DB
037-579152-001
, 5 , LC, 6DB
037-579153-001
, 10 , LC, 6DB
037-579154-001
, 3 , LC, 10DB
037-579155-001
, 5 , LC, 10DB
037-579156-001
, 10 , LC, 10DB
037-579157-001
LC2
1.
2.
VI--18
DAC.
,
.
Eclipse
STM1/OC3 (BNC)
.
DAC 2 155:
BNC BNC1
, ., . BNC . BNC,
2
1-1700143-3
BNC BNC
, ., . BNC . BNC,
5
1-1700143-4
/, STM1, .2
076-330504-001
1.
2.
Ethernet RJ45
.
DAC ES DAC GE:
037-579124-001
037-579125-001
037-579126-001
037-579127-001
AUX
EXA-001
AUX.
VI--19
Eclipse, E.
037-579112-001
AUX HD26, 2 , .,
037-579114-001
INU
037-579112-001
037-579113-001
AUX HD26, 2 , .,
037-579114-001
AUX HD26, 2 , .,
037-579115-001
037-579116-001
037-579117-001
037-579120-001
037-579121-001
IDU
037-579112-001
037-579113-001
037-579118-001
037-579119-001
037-579177-001
037-579178-001
VI--20
D.
ODU
:
:
:
Belden 9913
Hansen RG-8/U
Cinta CNT-400
Cinta CNT-300
Andrew BR-400C
Belden 9913
9913 - RG-8/U
:
: 50
: 10 AWG, ,
. 2,7 (0,108 )
:
VI--1
: Duobond II +90%
:
: 10,2 (0.405 )
(): 150 (6 )
. : 0,9
304 (1000 )
. : 1,8 304
(1000 )
400 : 8,53 100 (328 )
: -40 +80oC
Hansen RG-8/U
Hansen :
: 50
: . 2,747
(0,108 )
: .
: AL/PET/AL + 90%
: , .
: 10,29 (0,405 )
(): 153 (6 )
. : 2,96
1000
. : 5,9
1000
400 : 8,52 100
Cinta CNT-400
: 50
: BCCAI (
)
:
: +
:
: 10,29 (0,405 )
VI--2
Eclipse
: 25,4 (1 )
. : 4,56
1000 (1,39 / 1000 )
. : 5,41
1000 (1,56 / 1000 )
450 : 8,8 100 (2,7 / 100 )
: -40 +85oC
Cinta CNT-300
: 50
:
:
: +
:
: 7,62 (0,3 )
: 22,2 (0,88 )
. : 6,96
1000 (2,12 / 1000 )
. : 7,25
1000 (2,21 / 1000 )
450 : 13,75 100 (4,4 / 100
)
: -40 +85oC
Andrew BR-400C
Andrew BR-400C :
10,3 (0,41 )
: 25,4 (1 ) , 200
(8 )
. : 0,81
304 (1000 )
. : 1,78
304 (1000 )
300 : 2,1 100 (328 )
VI--3
:
Andrew CNT 300 CNT 400
N- Beldon Kai Jack
: N-
Andrew Andrew BR-400
Andrew Andrew GK-400
400
6,0 , 0,24
4,5 , 0,18
6,5 , 0,26
5,0 , 0,20
6,5 , 0,26
5,0 , 0,20
VI--4
Eclipse
VI--5
: N-
.D-3
N-. 9913 / RG-8/U.
. D-3. N- 9913
VI--6
Eclipse
Andrew BR-400
. D-4. Andrew BR-400
VI--7
Eclipse
Andrew GK-400
. D-5. Andrew
VI--9
VI--10
E.
INU/INUe IDU
:
DAC IDU
NMS
, NMS- Eclipse
.
, .
9500 MXC, ,
NMS- .
.
DAC
IDU
:
DAC 16x,
DAC 4x IDU
DAC ES
VI--1
DAC 16x,
:
Mini RJ-21 BNC DAC 16x .E-2
- Mini RJ-21 RJ-45 DAC 16x
.E-4
Mini RJ-21 DAC 16x
.E-8
Mini RJ-21 DAC 16x .E-10
Mini RJ-21
.
- . ,
Harris Stratex Networks, ,
.
81/DS1
VI--2
Eclipse
Mini RJ21.
RG-179B/U.
. E-2 .
E-2. ,
DATA1/9
DATA1/9
VI--3
. E-3 .
E-3. Mini RJ-21 BNC DAC 16x
VI--4
Eclipse
. E-4 .
8 .
81/DS1 ,
DAC 16x.
E-4. Mini RJ-21 RJ-45 DAC 16x,
81/DS1
, #24 AWB, .
Mini RJ21.
, .
8 RJ-45.
. E-5 RJ-45.
.
E-5. RJ-45
8
VI--5
. E-6 .
E-6. Mini RJ-21 RJ-45 DAC 16x
VI--6
Eclipse
. E-7 -.
RJ-45:
1 2 (Data In) DAC.
4 5 (Data Out) DAC.
E-7. - Mini RJ-21 RJ-45 DAC 16x.
VI--7
Mini RJ-21
DAC 16x
2 , 5 7,5 .
120 .
.
. E-8 .
8 .
81/DS1 ,
DAC 16x.
E-8. Mini RJ-21 DAC 16x
VI--8
Mini RJ21.
, #24 AWB, .
Eclipse
. E-9 .
1/9 . E-9 , 1,
1-8, 9,
9-16. 2/10, 3/11 .., 8/16.
E-9. Mini RJ-21
DAC 16x
VI--9
( )
12
13
25
48
37
, Tx, DAC
.
, Rx, DAC
.
E-1. Mini RJ-21
VI--10
1,
1,
2,
2,
5,
5,
10
6,
Eclipse
11
12
6,
13
1,
14
15
1,
16
2,
17
18
2,
19
5,
20
21
5,
22
6,
23
24
6,
25
3,
26
27
3,
28
4,
29
30
4,
31
7,
32
33
7,
34
8,
35
36
8,
VI--11
37
3,
38
39
3,
40
4,
41
42
4,
43
7,
44
45
7,
46
8,
47
48
8,
VI--12
9,
9,
10,
10,
13,
13,
10
14,
11
Eclipse
12
14,
13
9,
14
15
9,
16
10,
17
18
10,
19
13,
20
21
13,
22
14,
23
24
14,
25
11,
26
27
11,
28
12,
29
30
12,
31
15,
32
33
15,
34
16,
35
36
16,
37
11,
VI--13
38
39
11,
40
12,
41
42
12,
43
15,
44
45
15,
46
16,
47
48
16,
DAC 4x IDU
:
RJ-45 BNC DAC 4x IDU .E-15
RJ-45 RJ-45 DAC 4x IDU .E-16
- RJ-45 RJ-45 DAC 4x IDU .E-17
RJ-45 DAC 4x IDU
.E-18
RJ-45 DAC 4x IDU .E-19
VI--14
Eclipse
RJ-45
RX
3
TX
BNC "" 75 .
VI--15
VI--16
RJ-45
Eclipse
IDU
VI--17
RJ-45 DAC
4x IDU
2 , 5 7,5 .
120 .
.
.
DAC 4x
. IDU 8x , IDU
16x - .
.E-5.
E-5.
DAC 4x IDU.
VI--18
Eclipse
4x IDU
E-12. RJ-45 ( )
VI--19
DAC ES
:
RJ-45 RJ-45
VI--20
Eclipse
NMS
:
NMS 10/100Base-T .E-21
V.24 .E-22
NMS 10/100Base-T
NMS Ethernet Portal ProVision.
LAN
RJ-45,
10/100Base-T.
Ethernet- .
Eclipse 10/100Base-T NMS.
Eclipse .
Ethernet - (Mdi
MdiX). .
Eclipse.
(
), - .
NCC V1, IDU ES, IDU 16x IDU 8x
, - .
.
E-7. NMS Ethernet RJ-45
Ethernet +
Ethernet -
Ethernet +
Ethernet -
VI--21
V.24
V.24
Portal. INU/IDU
V.24 RJ-45 DB-9.
E-8. V.24 RJ-45
DSR/RI
CD
DTR
GND
RXD
TXD
CTS
RTS
VI--22
Eclipse
AUX () IDU ().
.
.
:
AUX
IDU
AUX
:
: , HD26
, 2 .E-24
: , HD26
, 2 .E-26
: , HD26 3 DB9,
1 .E-28
: , HD26 3 DB9,
1 .E-29
: , AUX HD26
AUX HD26, 1 .E-31
: , AUX HD26 AUX
HD26, 1 .E-32
/ AUX: HD15
, 2 5 .E-34
- .
VI--23
: ,
HD26 , 2
: 037-579114-00
E-15. AUX HD26, 2M, ,
E-9.
TIA/E1A-562
DCE
Aux RXD1
4
5
Aux TXD1
GND
10
11
12
Aux RXD2
13
14
15
VI--24
Aux TXD2
Eclipse
16
17
18
GND
()
Drain
19
20
24
25
26
21
Aux RXD3
22
23
Aux TXD3
/, /, /,
/, /, /
, /
037-579114-00
VI--25
: ,
HD26 , 2
: 037-579115-00
E-16. AUX HD26, 2M, , ,
E-10.
VI--26
TIA/E1A-422
DCE
1AuxRXC+
1AuxRXC-
1RXD-
1RXD+
1TXD+
1TXD-
1AuxTXC+
1AuxTXC-
GND
10
2AuxRXC+
11
2AuxRXC-
12
2RXD-
13
2RXD+
14
2TXD+
15
2TXD-
Eclipse
16
2AuxTXC+
17
2AuxTXC-
18
GND
()
19
3AuxRXC+
20
3AuxRXC-
21
3RXD-
22
3RXD+
23
3TXD+
24
3TXD-
25
3AuxTXC+
26
3AuxTXC-
/, /, /,
/, /, /
, /
Drain
037-579115-00
VI--27
: ,
HD26 3 DB9, 1
: 037-579116-00
E-17. AUX HD26 3 DB9, 1, :
E-11.
AUX
AUX 1
AUX 2
AUX 3
TIA/E1A-562
DCE
AuxRXD1
AuxTXD1
GND
12
AuxRXD2
14
AuxTXD2
18
GND
()
21
AuxRXD3
23
AuxTXD3
037-579116-00
VI--28
Eclipse
: ,
HD26 3 DB9, 1
: 037-579117-001
E-18. AUX HD26 3 DB9, 1, ,
E-12. 037-579117-001
AUX
AUX 1
AUX 2
AUX 3
TIA/E1A-422
DCE
1AuxRXC+
1AuxRXC-
1RXD-
1RXD+
1TXD+
1TXD-
1AuxTXC+
1AUXTXC-
GND
10
2AuxRXC+
11
2AuxRXC-
12
2RXD-
13
2RXD+
VI--29
VI--30
AUX
AUX 1
AUX 2
14
2TXD+
15
2TXD-
16
2AuxTXC+
17
2AUXTXC-
18
GND
()
19
3AuxRXC+
20
3AuxRXC-
21
3RXD-
22
3RXD+
23
3TXD+
24
3TXD-
25
3AuxTXC+
26
3AUXTXC-
AUX 3
Eclipse
: , AUX
HD26 AUX HD26, 1
: 037-579120-001
E-19. AUX AUX, HD26, 1, ,
E-13. 037-579120-001
AUX
AuxRXD1
AuxTXD1
AuxTXD1
AuxRXD1
12
AuxRXD2
AuxTXD2
14
14
AuxTXD2
AuxRXD2
12
18
18
21
AuxRXD3
AuxTXD3
23
23
AuxTXD3
AuxRXD3
21
AUX
VI--31
: , AUX
HD26 AUX HD26, 1
: 037-579121-001
E-20. AUX AUX, HD26, 1, ,
E-14. 037-579121-001
VI--32
AUX
AUX 1
1AuxRXC+
1AuxTXC+
1AuxRXC-
1AuxTXC-
1RXD-
1TXD-
1RXD+
1TXD+
1TXD+
1RXD+
1TXD-
1RXD-
1AuxTXC+
1AuxRXC+
1AUXTXC-
1AUXRXC-
GND
GND
10
2AuxRXC+
2AuxTXC+
16
11
2AuxRXC-
2AuxTXC-
17
12
2RXD-
2TXD-
15
13
2RXD+
2TXD+
14
14
2TXD+
2RXD+
13
15
2TXD-
2RXD-
12
16
2AuxTXC+
2AuxRXC+
10
17
2AUXTXC-
2AUXRXC-
11
Eclipse
AUX
18
GND
GND
18
19
3AuxRXC+
3AuxTXC+
25
20
3AuxRXC-
3AuxRTXC-
26
21
3RXD-
3TXD-
24
22
3RXD+
3TXD+
23
23
3TXD+
3RXD+
22
24
3TXD-
3RXD-
21
25
3AuxTXC+
3AuxRXC+
19
26
3AuxTXC-
3AuxRXC-
20
AUX 1
VI--33
/ AUX: HD15
, 2 5
: 037-579112-001, 2
: 037-579113-001, 5
E-21. ALARM I/O, HD15, 2, ,
E-15. 037-579112-001
TTL 1
1 NC
1 NO
2 Pole/TTL 5
3 NC
3 NO
4 Pole/TTL 3
TTL 2
10
1 Pole/TTL 6
11
2 NC
Drain
Eclipse
12
2 NO
13
3 Pole/TTL 4
14
4 NC
15
4 NO
/, /
037-579113-001
VI--35
IDU
:
AUX IDU: , DB9
, 2 .E-36
AUX IDU: , DB9
, 5 .E-37
AUX IDU: , IDU AUX DB9 IDU AUX
DB9, 1 .E-39
AUX IDU: , IDU AUX DB9 IDU AUX DB9, 1
.E-40
/ AUX IDU: HD15
, 2 5 .E-40
- .
E-16. 037-579177-001
VI--36
AUX
TIA/E1A-562
RXD
TXD
DCE
Eclipse
AUX
GND
/, /, /
, /, /
Drain
E-17. 037-579178-001
AUX
TIA/E1A-422
DCE
RXCLK+
RXD-
TXD+
TXCLK+
GROUND
Drain
VI--37
VI--38
AUX
RXCLK-
RXD+
TXD-
TXCLK-
Eclipse
E-18. 037-579118-001
AUX
AUX
1
2
RXD
TXD
TXD
RXD
GND
GND
4
5
VI--39
E-19. 037-579119-001
AUX
AUX
RXCLK+
TXCLK+
RXD-
TXD-
TXD+
RXD+
TXCLK+
RXCLK+
GROUND
GROUND
RXCLK-
TXCLK-
RXD+
TXD+
TXD-
RXD-
TXCLK-
RXCLK-
/ AUX IDU:
HD15 , 2 5
/
( AUX). . / AUX:
HD15 , 2 5 .E-34.
VI--40
F.
NMS Eclipse
Eclipse IP-
.
:
.F-1
, .F-2
.F-8
.F-8
,
50,
Harris Stratex Networks..
,
IP-
.
, , , ,
.
VI--1
,
;
Eclipse, - Portal
Ethernet.
, Eclipse
F-1. Eclipse
Eclipse
. ,
.
Eclipse IP-
Ethernet- NMS: - Ethernet-.
, NMS LINK, INU
, INUe , , :
- , Portal
IP- (Single IP addressing) (
Ethernet-),
IP- - , Portal
IP- (Interface IP addressing).
.
IP-
, IP-.
, ,
. IP- - /Ethernet.
Eclipse.
:
. . . F-8 . F-20.
IP-,
IP-
,
.
VI--2
Eclipse
: IP-
,
, .
,
.
,
NMS
, NMS
LINK ,
, Ethernet-, IP- 0.0.0.0
255.255.255.255.
: NMS
- ,
IP-.
, NMS
LINK ,
, Ethernet-.
V.24
, ,
.
.
IP- Single IP Address,
Ethernet- Interface Addressing IP ,
Portal
Send ().
Eclipse
. ,
- ( Eclipse),
, .
: IP- , IP-
, , .
VI--3
,
Eclipse
- IP-
.
/
NMS Ethernet,
( IP- ),
( IP- ).
/ Eclipse,
Ethernet, LAN.
Portal / Eclipse
Ethernet- IP-
LAN.
Portal LAN Eclipse,
, , TCP/IP c Portal
:
/ Eclipse ;
/ Eclipse ,
(
).
Eclipse. ,
, Eclipse (
Ethernet NMS).
(LAN),
LAN
.
VI--4
Eclipse
Portal :
Destination ( ):
.
IP-.
Subnet Mask ( ):
IP-.
Interface (): ,
/,
. ,
, , LINK 1 NMS LINK 2 NMS,
RAC. (
RAC).
Next Hop ( ):
, IP-
Ethernet-.
, '',
.
: Next Hop
(LINK),
.
Ethernet-, LAN
,
LAN, .
IP-, IP-.
, NMS LINK
, .
Portal
. F-3. . F-7 . F-5 . F-9.
: OSPF, RIP1 RIP2:
OSPF ,
, IP-.
RIP2 RIP1. RIP2 RIP1.
OSPF , RIP,
- 15.
.
VI--5
,
Eclipse IP- (
) RIP, , -
IP- . ,
Eclipse, RIP 1 RIP
2, 15, RIP.
:,
(, Altium), 7
,
IP-, Ethernet
.
IP-.
Eclipse
/, ,
Eclipse ,
.
Eclipse.
V.24 IP-.
.
/.
Eclipse
,
.
Ethernet NMS Eclipse,
,
LINK NMS, Eclipse
. . . F-8 . F-20.
VI--6
Eclipse
,
X4
, Ethernet- Portal
V.24, Ethernet-
Portal
Eclipse. , V.24, Ethernet-
IP- :
V.24 , IP-
. , Ethernet. V.24
Portal
, ping, tracert
.
, Eclipse, Ethernet-,
LAN, LAN
.
/ Eclipse
( LAN ),
,
.
IP-
TCP/IP LAN. ,
LAN NMS Eclipse.
TCP/IP 2 Portal.
.
VI--7
Eclipse .
.
C,
A B
. ,
, .
- ,
. :
A: 10.0.0.0 10.255.255.255
B: 172.16.0.0 172.31.255.255
C: 192.168.0.0 192.168.255.255
172.16.. ,
NOC LAN.
192.168.255.0 192.168.255.255
, ()
Eclipse.
IP- Eclipse.
:
.F-9
.F-10
.F-12
.F-17
.F-23
VI--8
Eclipse
. F-1 . F-9 INU INU:
C.
.
, c Portal .
TCP/IP
.
( DOS).
F-1. 1 Eclipse:
INU
IP-
:
Link 1*
INU
Link 1*
192.168.1.1
255.255.255.0
Ethernet
Portal
192.168.2.1
255.255.255.0
IP
.
192.168.2.0
255.255.255.0
Link 1 NMS
0.0.0.0
192.168.1.0
255.255.255.0
Link 1 NMS
0.0.0.0
:
OSPF RIP.
PORTAL
IP-
LAN Ethernet:
IP-
192.168.2.2
255.255.255.0
192.168.2.1
* Link 1 =
Link ,
RAC.
VI--9
.F-2 Eclipse.
, .
.
,
.
. F-3 . F-11
Portal .
, Portal ,
.
F-2. 2 Eclipse: , , , D
INU
C
192.168.3.1
255.255.255.0
Link 1
Portal
Ethernet
Link 2
INU
A
Link 3
Link 1
192.168.1.1
255.255.255.0
INU
B
Link 3
Link 1
INU
D
192.168.4.1
255.255.255.0
192.168.2.1
255.255.255.0
IP
. (:
.)
VI--10
192.168.2.0
255.255.255.0
Link 3 NMS
0.0.0.0
192.168.3.0
255.255.255.0
Link 3 NMS
0.0.0.0
192.168.4.0
255.255.255.0
Link 3 NMS
0.0.0.0
192.168.1.0
255.255.255.0
Link 1 NMS
0.0.0.0
192.168.3.0
255.255.255.0
Link 2 NMS
0.0.0.0
192.168.4.0
255.255.255.0
Link 3 NMS
0.0.0.0
192.168.2.0
255.255.255.0
Link 1 NMS
0.0.0.0
192.168.1.0
255.255.255.0
Link 1 NMS
0.0.0.0
192.168.4.0
255.255.255.0
Link 1 NMS
0.0.0.0
Eclipse
192.168.2.0
255.255.255.0
Link 1 NMS
0.0.0.0
192.168.3.0
255.255.255.0
Link 1 NMS
0.0.0.0
192.168.1.0
255.255.255.0
Link 1 NMS
0.0.0.0
:
OSPF RIP.
PORTAL
IP-
LAN Ethernet:
IP-
192.168.1.2
255.255.255.0
192.168.1.1
* Link 1 =
Link ,
RAC.
.F-2
Lyons Dpt
3]
192.168.2.1
VI--11
NOC NMS.
(default gateway)
Eclipse
/
NOC (NOC Network Operating Center )1:
NOC
/.
NOC
- /
/,
.
/ ,
NOC (, ), NMS
(ProVision / Portal) / NOC LAN
.
NOC LAN (, )
TCP/IP. (
Ethernet, Portal ,
/
). /
.
. F-4 . F-13 LAN NOC,
.
. F-5 . F-15 ,
, LAN NOC.
NOC. NOC,
,
NOC.
VI--12
Eclipse
F-4. :
NOC LAN
INU
A
192.168.1.1
255.255.255.0
192.168.5.1
INU
255.255.255.0 D
Link 1
Link 1
Link 1
INU
B
192.168.4.1
255.255.255.0
Link 2
Link 1
Link 2
INU
Link 3
Link 1
INU
E
Ethernet
192.168.2.1
255.255.255.0
Ethernet
192.168.3.1
255.255.255.0
NOC LAN
192.168.4.0
255.255.255.0
PORTAL
IP-:
192.168.2.2
:
255.255.255.0
: 192.168.2.1
NOC
Static Routing
(
)
---
---
---
Link 1 NMS
0.0.0.0
0.0.0.0
B
Static Routing
(
)
192.168.1.0
255.255.255.0
Link 1 NMS
Link 2 NMS
0.0.0.0
192.168.1.0
255.255.255.0
Link 1 NMS
0.0.0.0
192.168.2.0
255.255.255.0
Link 1 NMS
0.0.0.0
Static Routing
(
)
VI--13
192.168.5.0
255.255.255.0
Link2 NMS
Link 3 NMS
0.0.0.0
---
---
---
Link 1 NMS
0.0.0.0
192.168.1.0
255.255.255.0
Link 1 NMS
0.0.0.0
192.168.2.0
255.255.255.0
Link 1 NMS
0.0.0.0
192.168.3.0
255.255.255.0
Link 1 NMS
0.0.0.0
192.168.5.0
255.255.255.0
Link 1 NMS
0.0.0.0
---
---
TCP/IP
NOC
IP-
192.168.4.2
255.255.255.0
192.168.4.1
192.168.4.3
255.255.255.0
192.168.4.1
192.168.4.4
255.255.255.0
192.168.4.1
192.168.4.5
255.255.255.0
192.168.4.1
0.0.0.0
D
Static Routing
(
)
Static Routing
(
)
VI--14
Eclipse
F-5. :
LAN NOC c
192.168.1.1
255.255.255.0
INU
A
192.168.5.1
INU
255.255.255.0 D
Link 1
Link 1
Link 1
INU
B
192.168.4.1
255.255.255.0
Link 2
Link 2
Link 1
INU
C
Link 3
Link 1
INU
E
Ethernet
192.168.2.1
255.255.255.0
192.168.3.1
255.255.255.0
Ethernet
192.168.4.2
255.255.255.0
PORTAL PC
IP-:
192.168.2.2
:
255.255.255.0
: 192.168.2.1
192.168.6.1
255.255.255.0
NOC
192.168.7.1
255.255.255.0
NOC LAN
192.168.6.0
255.255.255.0
1
Static Routing
(
)
192.168.1.0
255.255.255.0
Link 1 NMS
0.0.0.0
192.168.2.0
255.255.255.0
Link 1 NMS
0.0.0.0
192.168.3.0
255.255.255.0
Link 1 NMS
0.0.0.0
0.0.0.0
192.168.5.0
255.255.255.0
Link 1 NMS
Ethernet
192.168.4.2
192.168.1.0
255.255.255.0
192.168.4.2
192.168.4.1
192.168.2.0
255.255.255.0
192.168.4.2
192.168.4.1
192.168.3.0
255.255.255.0
192.168.4.2
192.168.4.1
192.168.5.0
255.255.255.0
192.168.4.2
192.168.4.1
NOC
Static Routing
(
)
VI--15
VI--16
TCP/IP
NOC
IP-
192.168.6.2
255.255.255.0
192.168.6.1
192.168.6.3
255.255.255.0
192.168.6.1
192.168.6.4
255.255.255.0
192.168.6.1
192.168.6.5
255.255.255.0
192.168.6.1
Eclipse
. F-6 . F-18 Eclipse
, , Altium, XP4, DXR
. ,
, Eclipse
. .F-7
Portal . ,
192.169.1.0 ( LAN), ,
/ .
U.
. F-8 . F-20 , Eclipse
.
Eclipse
( ),
IP- (
).
Eclipse (LINK NMS) Portal
Interface Addressing (RIP2
OSPF). Ethernet Static Routing
Ethernet-.
NMS LINK
. , NMS
(PPP),
IP-.
, NMS LINK
,
, Ethernet-, IP- 0.0.0.0
255.255.255.255. IP- NMS-
.
IP-
,
,
.
,
.
, V.24 IP-.
IP- V.24 Interface Addressing
Portal V.24.
VI--17
F-6. 3 Eclipse:
, , , D Eclipse: : U, V, X, Y
Portal
192.168.50.1
255.255.255.0
192.168.51.1
255.255.255.0 V
Ethernet
192.168.1.2
255.255.255.0
INU
C
192.168.3.1
255.255.255.0
Ethernet
Link 1
192.168.3.2
255.255.255.0
Ethernet
Link 2
INU
A
Link 2
Link 1
192.168.1.1
255.255.255.0
INU
B
Link 3
Link 1
192.168.2.1
255.255.255.0
INU
D
192.168.4.1
255.255.255.0
VI--18
192.168.1.0
255.255.255.0
Ethernet-
0.0.0.0
192.168.50.0
255.255.255.0
Ethernet-
192.168.1.2
192.168.2.0
255.255.255.0
Link 2 NMS
0.0.0.0
192.168.3.0
255.255.255.0
Link 2 NMS
0.0.0.0
192.168.51.0
255.255.255.0
Link 2 NMS
0.0.0.0
192.168.4.0
255.255.255.0
Link 2 NMS
0.0.0.0
192.168.1.0
255.255.255.0
Link 1 NMS
0.0.0.0
192.168.50.0
255.255.255.0
Link 1 NMS
0.0.0.0
192.168.3.0
255.255.255.0
Link 2 NMS
0.0.0.0
192.168.51.0
255.255.255.0
Link 2 NMS
0.0.0.0
192.168.4.0
255.255.255.0
Link 3 NMS
0.0.0.0
192.168.2.0
255.255.255.0
Link 1 NMS
0.0.0.0
192.168.1.0
255.255.255.0
Link 1 NMS
0.0.0.0
192.168.50.0
255.255.255.0
Link 1 NMS
0.0.0.0
192.168.3.0
255.255.255.0
Ethernet-
0.0.0.0
192.168.51.0
255.255.255.0
Ethernet-
192.168.3.2
192.168.4.0
255.255.255.0
Link 1 NMS
0.0.0.0
192.168.2.0
255.255.255.0
Link 1 NMS
0.0.0.0
192.168.1.0
255.255.255.0
Link 1 NMS
0.0.0.0
192.168.50.0
255.255.255.0
Link 1 NMS
0.0.0.0
Eclipse
192.168.3.0
255.255.255.0
Link 1 NMS
0.0.0.0
192.168.51.0
255.255.255.0
Link 1 NMS
0.0.0.0
PORTAL
IP- LAN
Ethernet:
IP-
192.168.3.3
255.255.255.0
192.188.3.1
192.168.1.1
VI--19
F-8.
: , , , D
10.10.19.6
255.255.255.0
10.10.17.3
255.255.255.0
10.10.18.2
255.255.255.0
10.10.16.1
255.255.255.0
INU
C
0.0.0.0
255.255.255.255
Ethernet
Link 1
10.10.18.1
255.255.255.0
Ethernet
10.10.16.2
255.255.255.0
Link 2
INU
A
Link 2
Link 1
0.0.0.0
255.255.255.255
INU
B
INU
D
Link 3
Link 1
192.169.2.1
255.255.255.0
192.169.4.1
255.255.255.0
: U, V, X, Y
: -
IP-
:
:
IP-, IP-
, Ethernet Link 2 NMS.
Ethernet
, .. ,
10.10.16.0.
LINK 2 NMS IP- 0.0.0.0
255.255.255.255.
RIP2 Link 2 NMS.
()
Ethernet- Y.
10.10.16.0
255.255.255.0
Ethernet-
0.0.0.0
10.10.17.0
255.255.255.0
Ethernet-
10.10.16.1
B:
IP- RIP2
:
VI--20
Eclipse
IP-, IP-
, Ethernet Link 1 NMS.
Ethernet C U
, .. ,
10.10.18.0.
LINK 1 NMS IP- 0.0.0.0
255.255.255.255.
RIP2 Link 1 NMS.
()
Ethernet- U V.
10.10.18.0
255.255.255.0
Ethernet-
0.0.0.0
10.10.19.0
255.255.255.0
Ethernet-
10.10.18.1
D:
IP- RIP2.
F-9. Interface Addressing A .F-8
10.10.16.2
VI--21
10.10.16.2
VI--22
Eclipse
.F-11 Eclipse .
Eclipse ,
OSPF RIP.
IP- (Single IP Addressing).
, ( )
, .
, .F-8.
, LINK 1 NMS
, LINK 2 NMS LINK 3
NMS .
F-11. : Eclipse
10.17.1.1
255.255.255.0
10.16.1.1
255.255.255.0
Link 3
Link 1
INU
A
Link 2
INU
F
10.16.6.1
255.255.255.0
Link 1
10.16.2.1
255.255.255.0
INU
B
Link 2
Link 2
Link 1
Link 1
INU
Link 2
INU
E
C
Link 2
Link 1
10.16.5.1
255.255.255.0
Link 2
INU
D
10.16.3.1
255.255.255.0
Link 1
10.16.4.1
255.255.255.0
(OSPF RIP)
.
.
VI--23
G.
Eclipse ,
, .
, ,
: II, 3.
:
(1+0) INU/INUe .G-1
ODU 300ep .G-11
.G-13
(1+0) INU/
INUe
INU .G-1
NCC FAN, , DAC 16x
RAC 30.
INU.
INUe NCC FAN.
, ,
NPC.
VI--1
V.24 Maint.
NCC
FAN
.
Ethernet
Compact
Flash
uP
DAC 16x
1
Tx
FIFO
MUX
Rx
FIFO
DMX
.
DC-DC
ADC
ODU
-48
-48
LIU
16
..
DMX
Tx
FIFO
MUX
VTX
MOD
NQUAD 311
PLXR
MOD
D/A
Q
311
DAC 16x
1
Tx
FIFO
MUX
MUX
DMX
VTX
DMD
A/D
AGC
ODU
126
RAC 30
LIU
16
Rx
FIFO
Rx
FIFO
DMX
Rx/Tx
TDM- A B
:
NCC .G-3
.G-4
TDM- .G-4
RAC 30 .G-4
RAC 10 .G-6
RAC 40 .G-8
Rx Tx (Rx/Tx Diversity Bus) .G-10
DAC .G-10
VI--2
Eclipse
NCC
NCC INU/INUe.
, NMS,
.
.G-1.
G-1. NCC
NCC
(Microprocessor, uP)
(Timing Processor)
TDM- ( ),
( )
( ). INU/INUe
NPC,
.
ODU - INU (ODU INU Telemetry
Channels)
INU/ODU,
RAC/ODU.
RAC .
TDM-.
Compact Flash
CompactFlash
NCC IDU ( Eclipse).
,
(- ) .
CompactFlash
,
.
Ethernet
(Ethernet Switch)
(Maintenance Port)
RJ-45
(V.24) Portal
.
VI--3
NCC
(ADC)
.
ADC
,
FAN.
ADC
1% INU/
INUe.
(DC
Converter)
INU/INUe.
.
TDM-
TDM- -
.
, -,
: E1, DS1, E3, DS3 STM1/OC3. , INU/INUe
E1, DS1, E3, DS3 STM1/OC3.
.
,
.
NCC;
NPC.
RAC 30
RAC 30 ODU 300, 28/30
QPSK 128QAM.
RAC 30
. G-1 . G-2.
VI--4
Eclipse
RAC 30:
(Bus Demux)
TDM- FIFO (First in,
First out) , ,
:
75xE1, 84xDS1, 4xE3, 3xDS3
STM1/OC3.
NMS, INU-INU.
.
Vantex-, :
- .
Portal
/ .
I Q,
90 .
- (D/A),
,
311 .
N-Plexer,
, 48 ,
ODU.
RAC 30:
ODU 126
. N-Plexer , ,
NCC.
126
- (AGC),
ODU, - (A/D).
Vantex-, :
.
FEC-.
.
.
VI--5
, ,
G.826, .
,
.
FIFO ,
(Bus Mus) TDM-.
RAC 10
RAC 10 ODU 100; . .G-2.
G-2. RAC 10
ODU
-48 . ODU
..
DMX
Tx
FIFO
MUX
QPSK
MOD
D/A
Q
MUX
Rx
FIFO
DMX
QPSK
DMD
QUAD
DMD
~
AGC
ODU 100
126
RAC 10
. - TDM
.
RAC 10:
(Bus Demux)
TDM- FIFO (First in,
First out) , ,
:
4, 8, 16xE1 201.
NMS, INU-INU.
.
QPSK-, :
FEC- -
.
Portal
QPSK.
I Q,
90 .
VI--6
Eclipse
,
,
320 .
N-Plexer,
, 48 ,
ODU.
RAC 10:
ODU 126
. N-Plexer , ,
NCC.
126 (AGC),
ODU, .
QPSK-, :
.
FEC-.
, ,
G.826, .
,
.
FIFO ,
(Bus Mus) TDM-.
VI--7
RAC 40
RAC 40 ODU 300; . . G-3 . G-8.
RAC 40 RAC 30, :
,
.
/ XPIC.
FEC- - .
G-3. RAC 40
..
DMX
Tx
FIFO
MUX
D/A
MOD
Q
uC
MUX
Rx
FIFO
DMX
NQUAD 311MHz
PLXR
MOD
311
DMD
A/D
~
AGC
ODU 300
126
A/D
RAC 40
. - TDM
.
XPIC
Rx/Tx
XPIC
RAC 40:
(Bus Demux)
TDM- FIFO (First in,
First out) , ,
:
75xE1, 84xDS1, STM1/OC3.
NMS, INU-INU.
.
, :
FEC-: -
.
Portal
/ .
I Q,
90 .
VI--8
Eclipse
- (D/A),
,
311 .
N-Plexer,
, 48 ,
ODU.
RAC 40:
ODU 126
. N-Plexer , ,
NCC.
126 (AGC),
ODU.
:
- (A/D).
- XPIC OUT, .
,
RAC 40 ,
.
RAC 40 (XPIC IN) (A/
D) , .
,
, - .
:
FEC-.
.
(
RAC 40).
,
, G.826.
,
.
FIFO ,
(Bus Mus) TDM-.
, ODU
RAC ODU
VI--9
50 . - Belden 9913,
INU-ODU 300 (985 ft.).
ODU ,
, N- .
,
RAC.
ODU ,
ODU.
ODU -48 ,
:
/ ODU
311 RAC
( )
126 ODU (
)
N-Plexer
RAC ODU.
DAC
DAC TDM-.
DAC
. DAC 4x, DAC 16x, DAC 3xE3, DAC
3xE3M, DAC 1x155o, DAC 2x155o, DAC 2x155e, DAC 155oM, DAC ES
DAC GE.
DAC 16x
DAC 16x . G-1 . G-2:
/ ,
(LIU).
VI--10
Eclipse
E1 (75 , 120
) DS1 ( AMI B8ZS)
LIU Portal. LIU
.
( TDM-)
(Bus Mux)
, 1
(DS1) TDM-.
NxE1 ( DS1), N
.
TDM-
, ,
E1 (DS1) LIU.
AIS, PRBS-
BER1.
ODU 300ep
ODU 300ep 5 15 18 38
,
. ODU 5 15
. 18 38 .
.G-4 ODU
5 15 .
PRBS .
VI--11
ODU
TX
311
IQ
DMDMOD
AGC
.
. .
TX IF
TX-IF LO
INU
PA
TX LO
TX
uP
N-PLXR
-48VDC
.
DC-DC
RX LO
RX-IF LO
126
AGC
LNA
AGC
Rx
311
RAC N-Plexer (AGC)
/ (IQ DMD-MOD).
I Q,
(Ref Osc) 10
RAC.
I Q (Tx
IF), 1700 2300
, (Tx
LO) . (IF LO) (TX LO) .
, (Tx).
(, Power
Amplifier) .
ODU
,
. ODU
NCC .
DC-DC
ODU
-48 .
(LNA, Low Noise Amplifier)
(Rx Mixer), (RX LO),
VI--12
Eclipse
1700 2300 .
, (IF
Mixer) 126
RAC.
.
ETSI FCC
.
Eclipse
.
(Tx Power Monitor).
,
, ODU
.
INU/INUe ,
, .
RAC 30 RAC 40.
RAC 10 ,
,2 .
. G-5 . G-14 INU
RAC 30. ,
DAC 16x NPC. NPC
DC-DC NCC.
VI--13
ODU ,
.
ODU
.
NCC
.
G-5. INU
NPC
V.24 Maint.
NCC
FAN
.
Ethernet
Compact
Flash
uP
DAC 16x
1
LAN 1-4
Tx
FIFO
MUX
Rx
FIFO
DMX
ODU
.
DC-DC
ADC
-48
-48Vdc
LIU
16
.
DMX
Tx
FIFO
MUX
VTX
MOD
D/A
Q
QUAD 311
MOD
311
DAC 16x
1
Tx
FIFO
MUX
MUX
DMX
VTX
DMD
NPLXR
~
AGC
A/D
OD
126MHz
RAC 30
LIU
Rx
FIFO
16
Rx
FIFO
DMX
Rx/Tx
NPC
-48
. .
DMX
Tx
FIFO
MUX
VTX
MOD
.
DC-DC
D/A
Q
QUAD 311
MOD
311 MHz
MUX
Rx
FIFO
DMX
VTX
DMD
A/D
NPLXR
~
AGC
OD
126
RAC 30
TDM- A B
(Tx/Rx Diversity Bus).
VI--14
Eclipse
RAC
.
200 . ,
: II, 3.
INU/INUe RAC
(Tx), - (Rx)
RAC. ,
RAC ,
(Tx), (Rx).
RAC INU
.
:
.G-15
.G-16
.G-16
.G-19
.G-6
RAC 30.
DAC,
DAC, RAC AUX.
:
(Tx) DAC TDM-.
RAC ( ) TDM-
DAC ODU.
RAC ( )
DAC, ODU (ODU
).
:
, RAC ,
RAC ( ) TDM- (
RAC ).
RAC
, RAC.
VI--15
RAC ,
(
RAC) TDM-.
,
. .
DAC TDM-.
RAC (
RAC) , RAC
,
. ,
TDM- RAC. -
RAC -
; ,
, ,
200 .
(Tx) .
G-6.
Tx
ODU
RAC
.
Tx
Tx
Rx
ODU
.
RAC
Rx
TDM-
DAC
Tx
Rx
,
.
(Tx) - RAC/ODU.
VI--16
Eclipse
(Tx)
- ,
.
:
(Tx) DAC TDM-.
RAC ( ) TDM-
DAC ODU.
( ) (Tx)
RAC.
RAC/ODU ( ).
:
, RAC ,
RAC ( ) TDM-
( RAC ).
RAC
, RAC.
RAC ,
(
RAC) TDM-.
,
.
RAC (
RAC) , RAC
,
. ,
TDM- RAC.
, RAC (
RAC) , RAC
,
. ,
TDM- RAC.
VI--17
G-7.
ODU
RAC .
Tx
Tx
Rx
ODU
.
RAC
Rx
TDM-
DAC
Tx
Rx
Eclipse
() RAC/ODU
, .
, ,
() RAC/ODU3.
;
- .
TDM-.
. G-8 . G-20 -
. B:
, RAC
, RAC - ,
.
,
( ), .
D B ,
, ,
"" .
B C, B
,
RAC4. B
.
,
, Eclipse.
.
4
RAC TDM-. RAC ODU,
RAC .
VI--19
G-8. ""
RAC/ODU
RAC/ODU
B
ODU
Rx
Tx
ODU
Tx
Tx
Rx
Rx
Tx
Rx
TDM-
DAC
.
C D
C
D
B C
Rx
Tx
Rx
Tx
Rx
Tx
Rx
Tx
VI--20
H.
TDM-
Eclipse.
INU,
INUe.
.
,
, .
:
.H-1
.H-2
.H-5
.H-1 ,
.
H-1. ,
TDM-
E1
100xE1 200 ,
Tx Rx .
VI--1
TDM-
DS1
128xDS1 256 ,
Tx Rx .
STM1/OC3
2xSTM1/OC3 4 ,
Tx Rx .
1, DS1 STM1
.
= ,
.
,
,
. . .H-1 , .H-2
64xE1,
100xE1.
VI--2
Eclipse
H-1.
P + d
P - d
RAC
RAC
d
DAC
INU/INUe
d
= P + d
H-2.
INUe
64xE1 RAC 30
100xE1
RAC 30 32xE1
RAC 10 16xE1
RAC 10 8xE1
DAC 16x
8xE1
,
RAC 30 (
751, 100DS1 1STM1/OC3),
TDM- .
, ,
,
RAC 40:
64/75xE1
84/100xDS1
STM1/OC3
INU/INUe
1001, 128DS1 2STM1,
STM1,
:
VI--3
INU STM1/OC3
. . .H-3.
,
INU/INUe, .H-4, RAC
40 641
, 128xE1.
H-3. STM1
ODU 300
STM1
STM1 (.)
STM1 (.)
STM1
.
ODU 300
- XPIC
INU
RAC 40
RAC 40
NCC
Fan
DAC 2x155o
2xSTM1
2xSTM1
2xSTM1
H-4. 75xE1
(150xE1)
ODU 300
75xE1
ODU 300
75xE1 (.)
.
ODU 300
75xE1 (.)
64xE1
.
ODU 300
RAC 40
Fan
RAC 30
NCC
INU
- XPIC
RAC 30
NCC
DAC 16x
Fan
RAC 40
75xE1
150xE1
64xE1
11xE1
VI--4
INU
11xE1
Eclipse
64/75xE1 84/100xDS1
RAC 40 .
: II, 4.
:
-;
. . -
.H-6.
-. .
- .H-7.
NxE1 NxDS1. , Eclipse
STM1/OC3,
SDH-,
Eclipse.
SDH STM1/OC3 Eclipse
-, .
VI--5
-
:
/ .
, /
.
, , , Tx (
) Rx ( ), .
,
:
,
E1
DS1
,
1
DS1
NxE1
R + d/2 100
2R + d 200
NxDS1
R + d/2 128
2R + d 256
:
R - ( );
d - /
( , )
.H-5 64xE1,
/ 16xE1.
H-5.
64
R = 64xE1
RAC
64-16
R = 64xE1
RAC
16
16
DAC
16xE1
R = = 64xE1
d = ./..
- . = 64 + (64-16) + 16 + 16 = 144
- . = 144/2 = 72
VI--6
Eclipse
:
,
E1/DS1
, / .
100 128 .
DAC /
RAC .
"-",
, 641
84DS1. , 751
1131 , . ,
641 (41
).
,
751
100xDS1, ,
.
" Eclipse
Super-PDH" Harris Stratex Networks.
INU/INUe
, .
-
"-"
, :
.
"-" .
- ,
.
VI--7
.H-6, 32xE1
- 321 :
H-6. "-"
A
32xE1
G
B
32xE1 :
64xE1 :
64xE1
32xE1 .
32xE1 -
1
-
D
, "-",
:
,
E1
DS1
,
1
DS1
NxE1
P + R + d/2 100
2P + 2R + d 200
NxDS1
P + R + d/2 128
2P + 2R + d 256
:
P "-",
. ( , ).
R ( ).
d /
( ).
VI--8
Eclipse
.H-7 48xE1
"-" 16xE1 (
- 64xE1 ).
H-7.
"-"
64xE1
RAC
RAC
48xE1 +
16xE1 -
64xE1
48xE1 +
16xE1 -
-
.1 16xE1
.2 16xE1
INUe
DAC ES
LAN
32
DAC 16x
8xE1 /
48
64xE1
RAC
48-8
RAC
64xE1
8
16
-
. 1
. 2
DAC ES
32 LAN
DAC 16x
16
8xE1
P = - ( ) =
R = = 48xE1
d = ./.
= P + R + d/2
= 32xE1 + 48xE1 + 4xE1 = 84xE1
VI--9
1001. ,
, :
P = "-" ( )
= 32xE1
R = = 48xE1
d = / =
24xE1
= 32 + 48 + 24 = 104,
. . .H-8.
H-8.
48xE1
64xE1
RAC
RAC
16xE1
-
DAC ES
64xE1
48xE1
/
= 104xE1
,
, /
.
VI--10
, Harris
Stratex Networks Eclipse, Eclipse Portal ProVision V.
, , EIA (177 / 7 )
AACS
ADC ()
- - ,
( ).
Address ()
, .
ADR
Altium ADR - STM-1,
-, STM-1,
(SNC-P) (MSP).
Altium ADR , :
- ( )
-
()
SNMP, Altium ADR ProVision.
AGS ()
;
, , .
AIS
C , .
.
Alarm Indication Signal (C )
.
.
ALC
ALM
: (AMI) .
. ,
. .
AMI
(AMI)
.
, .
.
Analog signal ( )
, . Eclipse
.
Analog-to-digital converter (- )
, ( ).
ANSI
AOU
Eclipse
ASCII
ASIC
ATM
Eclipse
ATPC
,
.
.
Automatic gain control voltage ( () )
, ,
.
AUX
Eclipse
Auxiliary Data Channel ( )
, ,
.
AWG
. . AWG,
.
Azimuth ()
(,
); .
B3ZS
3 . "1".
B8ZS
8 .
BAPT
Bundesamtfur Post Und Telekommunikation ( )
BBP
BCH ()
--: ,
, 25
.
Beamwidth ( )
(-3 ) (
).
BER
: , ,
.
BML
TMN
BNC
BNC.
BOM
bps
BSI
Bursty Traffic ( )
Centigrade ( )
, 100
: 0 100 .
CB-149
Bell Core, ITU.
CCITT
CDMA
()
CE
: ",
, ." ( Urn 94/
634)
CEMF
Cisco
CEPT
CEPT-1
1 ITU-T (2.048 /) = E1
CEPT-2
2 ITU-T (8.448 /) = E2
CEPT-3
3 ITU-T (34.368 /) = E3
CEPT-4
4 ITU-T (139.264 /)
Eclipse
CEPT-n
CEPT - n
CLEC
() ( )
CMOS ()
--
CODEC
coder/decoder (/). , .
, ,
, , .
Commissioning ( )
.
Community String (C )
SNMP , "community string" ( )
.
, ( ).
: ,
() . Public ()
Private (), .
Component
. , CTU,
, ODU, AOU.
CORBA
.
CRC
CSDS
, Harris Stratex Networks
.
(, , ), .
CSV
,
CTB
CTU
1) Eclipse; 2) . ,
c DART.
D/A
DAC
1) Eclipse: 2)
DART
. .
dB
; .
DB9
9-
dBm
, = 0 dBm.
.
dc
. Harris Stratex Networks ()
.
dc-dc Converter ( )
,
.
DCE ()
DDS
DEMUX
Device ()
SNMP ProVision. SNMP:
Harris Stratex Networks, DXR SMA, Altium ADR,
, , .
DFE
Diagnostic Controls ( )
Eclipse
Eclipse,
. : () ,
.
Diagnostic Functions ( )
Eclipse,
. : () ,
.
Diplexer ()
-, .
Digital signal ( )
, .
Digital signal 1 (DS1)
ANSI - 1,544 /,
T1.
Direct current ( )
Harris Stratex Networks () .
DLC
DQPSK
DS
: , .
DS1
: ANSI - 1.544 /
, T1.
DS3
1) ANSI - 44,376 /,
T3.; 2) 32,064 /
T3.
DSx
ANSI - x
DTE
1) . , ,
; 2)
Dual Link ( )
Eclipse - , 2+0.
. (primary)
1 8 , (standby) 9 16 .
, 9 16 .
9 16 , .
DTMF
( )
DUART
DVM
DXR
E1
1 ITU (2.048 /) = CEPT 1
E3
3 ITU (34.368 /) = CEPT 3
E/I
/
E/N
/
ECC
Eclipse
INU ODU300 / ODU 100.
() .
4xE1/DS1 2xSTM1/OC3. QPSK 256QAM.
: , ,
.
Eclipse
IDU ODU 100. : 8x 4x 8xE1
16x 4x, 8x 16x. - QPSK.
.
EEPROM
-
EIA
Eclipse
EISA
. 32-
. ,
8- 16- ISA ( ).
Electromagnetic Spectrum ( )
26 , ITU
12 , 30 3000 .
EM
EMC
EMI
EML
TMN
EMS
End-to-end delay ( )
, .
EOW
C ( / )
ERP
ESD
ETSI
. .
. Harris Stratex Networks
ETSI.
European Telecommunications Standards Institute (
)
. .
Harris Stratex Networks ETSI.
Extended Industry Standard Architecture (
)
32- .
, 8- 16- ISA (
).
Fahrenheit ()
, 212 , 32
.
Fade margin ( )
, .
: RX RSSI.
FAN
Eclipse
FCAPS
, , ,
TMN.
FCC ()
. ,
. 1934 ,
, , ,
. 50 ,
.
FEC
.
, ,
, .
XP4 Plus 2x.4x. 4x/8x 2 512
. DS-3 E3/16E1 XP4 Plus 8
255 .
FFE
FIFO
" - "
FIR
FM
Fault management ( )
Forward Error Correction ( )
,
, ,
. XP4
Plus 2x.4x. 4x/8x 2 512 .
DS-3 E3/16E1 XP4 Plus 8 255 .
FPGA ()
10
Eclipse
.
. ,
.
Frequency-shift keying ( )
.
G.821
G0,821: ISDN
.
G0,826
G.826:
.
Ga AsFET
Gain ()
(,
).
GB
GHz
Golden Cells ( )
, .
, , ,
, , ,
, ,
.
GSM
GUI
H.323
, ITU,
-, . , H.323
, .
High Density Bipolar Order 3 - HDB3 ( )
E1 E3. "1" 3 .
Hitless Receive Switching ( )
11
,
.
- .
.
. ,
.
HPA
HSB
( )
HSC
/ .
.
.
HTML
/
/
ICMP
. .
IDC
. , ,
. IDC 1U. IDCe ( IDC)
2U.
IDU
(IDU) .
ODU.
.
.
, /.
IIOP
CORBA Internet Inter-ORB
Indoor Unit ( )
12
Eclipse
(IDU) .
ODU.
.
Eclipse
(ODU) , ,
. ,
: INU, INUe IDU.
IDU 1U 4 20xE1 QPSK.
ODU 100.
4/8xE1, - 4/8/16xE1.
Intermediate frequency (IF - )
, /.
Intermodulation ()
.
(
- ) , ,
.
.
, .
/
, .
-
, ( 1 ) , ,
,
,
. -,
, , ,
- .
International Telecommunications Union ( )
, .
INU
. Eclipse
(ODU) , ,
. ,
: INU, INUe IDU.
INU 1U (IDC),
. ODU
/ . INU :
IDC ( 1U)
NCC ( )
FAN ( )
RAC ( ), DAC ( ),
AUX ( ) NPC ( )
13
INUe
. Eclipse
(ODU) ,
, . ,
: INU, INUe IDU.
INUe 2U (IDCe),
( NCC FAN) .
ODU /
.
IP
IRU
ISI
ISO
ITU-R
( CCIR IFRB)
ITU-T
- ( CCITT)
ITU13
LAN ()
LBO
Line Build-Out ( /)
. IDU .
Light Emitting Diode ()
IDU .
Link
- .
LinkView
. LinkView
,
(IDU).
LMCDR
14
Eclipse
/
LMT
LNA
LO
Local
(IDU) (ODU) , ,
. .
Local terminal ( )
, Eclipse Portal ( ).
Loopback ()
,
, , .
.
LOS
1) ; 2)
MAC address
, . ,
.
Management Information System ( )
, .
Mbps (/)
Message board ( )
,
.
MGB
MHSB
MHz
= 1 . .
MIB
15
.
-.
SNMP.
Microwave Monolithic Integrated Circuit ( )
ODU MMIC .
MIS
, .
mm
16
Eclipse
Mute ()
.
MUX
NBI
NCC
Eclipse -
NE
NEL
TMN
Network Management Interface (NMI - )
XP4 Plus NMI.
IDU SNMP . SNMP,
.
Network operator ( )
, .
Network Management Interface ( )
XP4 Plus NMI.
IDU SNMP . SNMP,
.
NML
TMN
NMS
.
NOC
,
, .
Nonprotected ()
, .
NPC
Eclipse -
O&M
17
Object Class ( )
, .
Object Group ( )
, ,
.
Outdoor Unit ( )
ODU IDU ODU . ODU
.
ODU 100
Eclipse
(ODU) , ,
. ODU 1+0.
ODU ODU 300 ODU 100. ODU 100
4 16xE1 23 .
- QPSK. INU IDU,
.
ODU 300
Eclipse
(ODU) , ,
. ODU 1+0.
ODU ODU 300 ODU 100. ODU 300
4xE1/DS1 2xSTM1/OC3,
3,5 56 , QPSK 256 QAM.
INU INUe.
OEM
ohm ()
.
, 1 1
. - Merriam Webster Online
Open Shortest Path First (OSPF - c )
18
Eclipse
OSPF , ,
RIP. RIP, OSPF
(IETF),
(Interior Gateway Protocol IGP). OSPF
. RIP, ,
OSPF . RIP
30 . OSPF ,
. , OSPF
, .
OSPF .
. OSPF
, . RIP
OSPF. RIP,
RIP,
OSPF.
Orderwire ( )
, ,
/ .
Oscillator ()
.
OSI
.
OSPF
Open Shortest Path First (OSPF - c )
OSPF , ,
RIP. RIP, OSPF
(IETF),
(Interior Gateway Protocol IGP). OSPF
. RIP, ,
OSPF . RIP
30 . OSPF ,
. , OSPF
, .
OSPF .
. OSPF
, . RIP
OSPF. RIP,
RIP,
OSPF.
OSS
19
OV Power
" - "
PA
PAM ()
-
Path ()
.
PC
PCA
PCB
PCM ()
-
,
.
Personal Communications Service (PCS - )
,
.
PDA
.
PDF
PDH
phase-locked loop (PLL - )
, ,
().
Ping
,
(ICMP echo request - ICMP) .
PIU
phase-locked loop (PLL - )
20
Eclipse
, ,
().
PLT
PM
PMA
PN
ppm
PPP
.
PROM ()
(ROM), .
Protection Switch ( )
, IDU
. IDU ( ),
.
ProVision
, Harris Stratex Networks,
.
ProVision Client Software
, ProVision ,
. ,
. ,
ProVision.
ProVision Server Software
ProVision ProVision.
.
.
ProVision.
Proxy
, .
PSTN
PSU
21
QAM
-
QoS
QPSK
R&D
-
RAC
Radio Frequency Interference ( )
Harris Stratex Networks ,
/ .
RAS
Received signal level ( )
. RSL 1 ,
0 .
Remote ()
IDU ( ) ODU ( ), ,
.
Remote terminal ( )
, .
RF ()
22
Eclipse
23
RSSI
RU
, , EIA (44,5 / 1,75 )
Receive ()
SAW
()
SDH
SES
SI
SNMP
SNMP IP ,
.
SLIP
SMA
SML
TMN
SMS
SNMP
SNMP IP ,
.
SNR
/
SONET
.
24
Eclipse
,
.
.
, (
). , ,
,
.
SQL
SSC
SSL
Static Routing ( )
. ,
.
STDM
.
(timeslot)
.
STM-0
ITU, (SDH),
51,84 /.
STM-1
ITU, (SDH),
155,52 /.
STM-N
N (Nx155,52 /: N = 1,4,16 64)
STS-N
N (Nx155,52 /: N = 1, 3, 12, 48 192)
Subnet ()
.
32- , ,
.
Switch unit (SU - )
. ,
IDU .
IDU ( ),
. MSU.
25
SWR ()
T-R Spacing ( )
. , ,
, .
.
T1
DS1
, DS1 1,544 /.
'T' , 'DS' ,
DS0, DS1, DS2 DS3.
T3
, DS3 44,7 /.
'T' , 'DS' ,
DS0, DS1, DS2 DS3.
TAE
TAPI
. XPView
(DART/XP4).
TBD
TCP/IP
/ Internet
TCXO
TELNET
Internet.
.
Telnet ,
.
. Telnet ,
. Telnet Web-.
26
Eclipse
TMN
Tombstone
, ,
.
Trap
(alarm message) , ,
.
, , .
SNMP.
ProVision.
. (, ) ,
, . , ,
.
Trib
Transistor-Transistor Logic (TTL - - )
. .
Texas Instruments 1965.
Transmit ()
UDP
.
SNMP.
UDP/IP
/Internet
UI
27
UV
V.24
. RS-232.
VCO ()
.
.
Volts Direct Current (Vdc - )
XP4 Plus ODU: 21,6 72 Vdc.
VDE
VF
Video graphics array (VGA)
IBM .
Viterbi
- ,
, , ,
( 100 ).
VLSI
Voltage Controlled Oscillator (VCO - )
.
Volts Direct Current (Vdc - )
XP4 Plus ODU: 21,6 72 Vdc.
VPN
VSWR
VT100
IDU NMI.
WAN
,
WAP
Eclipse
WMT
WR-xx
,
.
XPD
-
XPIC
-
XML
[], XML
29
30
, V 2 23
, V 2 34
Ethernet,
V 2 38
IDU, V 2 34
AUX, V 2 38
,
V 2 37
, V 2
35
FAN, V 2 39
, V 2 23
AUX, V 2 29
DAC, V 2 28
DAC ES, V 2 30
DAC GE, V 2 31
FAN, V 2 34
NCC, V 2 24
NPC, V 2 29
RAC, V 2 25
Configuration Not Supported, V 2 10
Portal, V 2 23
SW/HW Incompatible, V 2 11
Eclipse
. ,
Eclipse, VI B 1
Eclipse, VI B 1
Configuration Not Supported,
V 2 10
SW/HW Incompatible,
V 2 11
, II 6 9
, III 5 14
, III 2 5
, V 2 10
, III 2 1
RSL, III 5 2
RSSI, III 5 3
, III
5 13
,
III 5 6
XPIC
CCDP, III 5 9
, III 5 2
, III 5 1
,
III 5 13
,
III 5 14
, III 5 4
,
III 5 5
, II 1 18
, I 1 4
, IV 14 1
ODU, II 1 16
, , III 5
14
, II 3
111
, IV 15 5
IP- ,
IV 10 2
, Portal, IV 1 1
DAC, V 1 20
, V 1 4
BER, V 1 4
, V 1 5
BER , V 1 5
, V 1 4
,
V 1 8
NCC/NPC, V 1 23
, V 1 15
, V 1 18
, V
1 11
, V 1 13
, V 1 18
, VI A 22
, V 1 25
, V 1 1
, I 1 4
Tmra, I 1 6
, III 2 11
DHCP-, IV 2 25
, II 3 122
, II 3 124
, II 3 126
BER-, IV 15 61
/ , II 3
ii
86
, IV 7 102
/ AUX,
II 3 86
-
, I 1 8
, I 1 3
, 1 i iii
PRBS
, IV 15 61
, II 3 95
, III 5 13
, IV 7 13
, I 1 5
, III 2 25
ODU, III 2 29
, III 2 27
, IV 8 13
AUX NMS, II
3 85
/
, IV 12 1
, IV 12 1
portal, IV 12 1
,
IV 12 1
, II 3 96
, IV 8 8
advanced management, IV 15 76
event browser, IV 15 8
performance, IV 15 31
system/controls, IV 15 2, IV 15
45
, IV 15 14
, IV 15 18
, IV 10 2
RoHS, 1 i v
WEEE, 1 i v
, II 3 84
1+1, IV 8 9
,
V22
, 1 iii xxx
, I 1 6
COM-, IV 2 13
Eclipse, IV 13 2
, IV
13 2
Connect ES, II 2 26
, II 3 113
, II 3 126
ODU, III 2 13
Eclipse, I 1 4
ODU, III 2 22
ODU, III 2 22, III 2 23
ESD, I 1 4
, III 3 12
- , V 1 5
,
IV 5 3
Portal, IV 2 20
DAC, II 3 115
NCC
NPC, II 3 128
NCC , II 3 95
, II 3 124
, II 3
122
, II 3 95, IV 7 13
, II 3 96, IV 8 1
, IV 8 8
1+1, IV 8 9
, IV 15 45
, II 3 94
, IV 8 1
, IV 8 1
,
II 3 117
, V 1 8
, II 3 98, VI A 2
,
II 3 126
, IV 7 14
, IV 8 1
IDU, IV 8 23,
IV 8 27
, II 3
124
,
II 3 123
DAC, II 3
127
, II 3 117
, VI A 10
, IV 8 23
, IV 8 4
iii
, IV 7
13
, II 3 92
, II 3 95
RAC,
IV 7 21
, IV 7 13
, IV 7 13
, IV 2 29, IV 14 1
, III 2 40
, III 2 40
, II 3 117
, II 3 92
, IV 15 45
,
IV 9 15
BER , V 1 5
RSL
, III 5 2
RSSI
, III 5 3
, IV 14 1
, IV 2 29
, V 2 14
IDU, V 2 20
, V 2 14
, V 2 14
-, I 1 8
, VI
D1
, III 1 3
AUX, II 3 84
, V 2 45
IDU, V 2 49
INU, V 2 45
iv
Portal, IV 6 1
, I 1 5
ODU, III 2 20
ODU
,
IV 3 2
IDU, III 4 3
INU/INUe, III 3 3
RJ-21 , VI E 8
n-, III 2 25
-, III 2 24
DAC ES, IV 7 58
DAC GE, IV 7 71
CompactFlash, IV 4 2
, IV 4 2
, IV 2 30
PDH
,
VI A 2
super PDH, II 3 98
, II 3 100, IV 7 14
, VI A 22
, VI A 22
,
VI A 22
, VI A 4
"-".,
II 3 104
Ethernet , II 3 108
super PDH, II 3 98
, II 3 102
, VI A
26
, VI A
26
, VI A 22
, II 3 105
, II 3 98, VI A 2
IP-, II 3 110
, II 3 126
, II 3 113
"-"., II 3 104
, II 3 124
, II 3
102
, II 3 100
North Gateway Any-to-Any,
II 3 99
, II 3 125
DAC
155oM, II 3 125
, IV 7 5,
VI A 12
, IV 15 54
-
,
VI A 17
, VI A 8
plug-ins, VI A 14
, VI A 9
, VI A 8
, VI A 8
networking, VI A 20
, II 3 104
, VI A 1, VI
A4
, VI A 5
, VI A 16
, IV 15 55
, VI
A 24
, VI A 25
, II 3 100, VI A 2
, VI A 3
, VI A 3
system/controls, IV 15 55
tx mute, IV 15 57
, VI A 6
, VI A 7
, VI A 24
, VI A
23
, IV 15 57
GK-400, VI
D4
GK-400
Andrew, VI D 4
, III 2 10
Harris Stratex Networks, 1 i iv
, II 6 11
AUX, IV 7 93
DAC 155o, 2x155o, 2x155e, IV 7 42
DAC 155oM, IV 7 47
DAC 16x DAC 4x, IV 7 31
DAC 3xE3/DS3, IV 7 36
DAC 3xE3/DS3M, IV 7 38
DAC ES, IV 7 56
DAC GE, IV 7 67
DAC, IV 7 27
IDU ES, IV 7 56
Ethernet, IV 7 56
, IV 11 3
IP-
,
IV 10 8
IP-
,
IV 10 8
, IV 14 1
/ AUX,
IV 7 102
, IV 8 1
, IV 8 13
,
IV 7 5
IP-
, IV 10 13
circuits, VI A 16
, VI A 16
circuits DAC ES, IV 9 7
IDU, IV 7 2
networking
, VI A 20
, IV 7 2
, VI A 21
,
V 2 10
IDU, IV 7
31
AUX, IV 9 18
, IV 9 2
, IV 9 9
, IV 9 1
AUX, IV 9 21
, IV 9
11
, IV
10 15
, IV 7 4
, IV 10 8
Portal ProVision, II 1 18
IDU, IV 7 27
INU/INUe, III 3 9
ProVision, II 5 6
,
IV 11 3
AUX, IV 9 18
, IV 9 2
/
vi
, IV 11 3
, II 3 117
, II 3 118
, II 3 118
-
, VI E 7
-
, II 3 4
Connect ES, IV 4 4
IDU300 20xV2, IV 4 6
, IV 4 3
, IV 4 3
Portal, IV 4 7
, IV 4 9
Portal, IV
4 11
, II 3 13
, IV 4 10
, IV 4 9
, IV 4 10
, I 1 6
VLAN, II 3 81
, IV 10 2
, IV 10 1
, IV 10 8
, I 1 6
, IV 13 2
, I 1 6
IDU, III 4 1
AUX, II 3 84
DAC 155oM, II 3 56
DAC 16x, II 3 47
DAC 1x155o, II 3 53
DAC 2x155o, II 3 53
DAC 3xE3/DS3, II 3 49
DAC 3xE3/DS3M, II 3 51
DAC 4x, II 3 46
DAC ES, II 3 61
DAC GE, II 3 70
DAC, II 3 45
FAN, II 3 22
NPC, II 3 90
RAC 10, II 3 40
RAC 30 RAC 3X, II 3 23
RAC 40, II 3 41
RAC, II 3 23
, III 3 12
, III 3 9
, IV
15 6
, IV 7 1, IV 7 2
, IV
15 6
AUX, II 1 15
DAC 155oM, II 1 14
DAC 16x, II 1 13
DAC 1x155o, II 1 14
DAC 2x155e, II 1 13
DAC 2x155o, II 1 14
DAC 3xE3/DS3, II 1 13
DAC 3xE3/DS3M, II 1 11
DAC 4x, II 1 12
DAC ES, II 1 14
DAC GE, II 1 15
FAN, II 1 11
NCC, II 1 11
NPC, II 1 15
RAC 10, II 1 12
RAC 30, II 1 11
RAC 3X, II 1 12
RAC 40, II 1 12
AUX, II 3 84
, II 6 10
, II 6 11
, II 6 10
, II 6 10
E13, II 3 51
M13, II 3 52
DATA/DAC
DAC,
IV 7 28
, IV 15 6
, IV 7 12
, V 2 10
, I 1 2
, VI A 12
, VI A 8
, VI A 8
, VI A 18
TCP/IP Portal, IV 2 6
, IV 14 1
,
IV 10 15
, IV 7 19
RJ-45, VI E 5
, 1 i iii
, IV 3 8
, IV 3 6
, IV
43
, I 1 3
, III 1 4
, III 1 4
vii
, VI A 26
, II 3 79,
IV 7 89
, I 1 6
, IV 15 1
alarm actions, IV 11 1
alarms, IV 15 14
as built report, IV 5 2
circuits, VI A 16
DAC ES, IV 9 7
event browser, IV 15 8
, IV 15 10
history, IV 15 18
layout
, VI A 8
licensing
, VI A 8
parts, IV 15 75
performance, IV 15 31
plug-ins
plug-ins, VI A 14
protection
, VI A 9
system summary, IV 15 2
system/controls, IV 15 45
, VI A 21
, I 1 2
, I 1 3
, I 1 4
, II 1 1
, VI A
25
, I 1 3
Ethernet, II 6 4
Portal, II 5 3
viii
Portal, II 5 2
, IV 13 6
tx
,
IV 7 12
, IV 15 57
, IV 15
51
ODU, III 3 13
, IV 3 2
, IV 11 1
, IV 11 1
, IV 5 1
, IV 5 1
Portal, IV 1 1
DAC ES, II 3 66
DAC GE, II 3 76
DAC ES, II 3 66
, I 1 4
34 / E3, II 3 52
()
, IV 15 55
, IV 15 6
,
V24
Portal, IV 1 5
Portal, IV 2 1
Portal, IV 2 2
Portal, IV 2 1
, VI A 4
"-", VI A 5
, II 1 7
Eclipse, II 1 1
, I 1 2
, III 1 4
, III 2 10
, III 2 10
, IV 1 3
, I 1 3
, V 2 1
, V 2 2
IDU, V 2 20
,
V25
Portal, V 2 1
ProVision, V 2 1
, V
2 40
, VI A 22
,
V 2 9
, V 2 5
, V 2 4
, V 2 3
- ,
V 2 9
, V 2 10
,
V29
, V 2 8
, V 2 2
, V 2 3
, V 2 9
AIS PRBS,
II 2 6
AIS, IV 15 58
, IV 8 13
, V 2 37
DS1, IV 7 34
1, IV 7 34
, V 2 12
, IV 15 58
, III 2 5
, V 2 9
RSL/RSSI, III 5 3
, VI A 4, VI A 6
DAC ES,
IV 9 17
DAC3xE3/
DS3M, IV 9 18
, IV 9 15
,
IV 9 15
, VI A 16
, VI A 24
, VI A 16
, IV 9
11
,
VI A 23
Portal, IV 1 8
INU/INUe, IV
17
, VI H 1
,
VI H 1
ix
IDU, II 2 10, II 2 29
, I 1 3
Connect ES, II 2 32
AUX,
II 3 85
"-", VI A 5
, VI A 6
RAC/IDU ODU, VI C 5
ATPC, V 2 12
,
V 2 11
, V
2 12
, V 2 12
, V 2 10
,
V 2 9
, V 2 9
,
V28
,
VI A 26
,
VI A 26
, VI A
24
, IV 13 1
DAC ES, II 3 64
DAC GE, II 3 74
E3, II 3 52
, V 2 23
, V 2 45
, IV 7 13
, V 1 25
Eclipse,
IV 3 8
Portal, IV 2 2
, IV 2 31
, III 5 4
, VI A 26
, VI A 2
XPIC, II 3
129
RAC 40, II 3 129
NPC, II 3 128
XPIC., II 3
129
, II 3 129
, IV
15 51
, IV 15 51
, IV 7 5,
IV 8 13
, IV 15 45
, IV 7 4
, IV 7 7
, VI A
25
, V 2 35
Eclipse
, I 1 3
, I 1 3
, I 1 5
ODU, III 2 20
1-8
, VI E 10
9-16
, VI E 12
maint V.24, VI E 22
, VI E 23
NMS 10/100Base-T, VI E 21
BR-400
Andrew, VI D 4
, VI D 1
RAC/IDU ODU, VI C 5
VLAN DAC ES, II 3 65
RAC 40, II 3 131
, III 1 4
, II 3 3
IP-, IV 10 13
, IV 15 76
clear events and history, IV 15 78
software reset, IV 15 77
-
,
VI A 5
, II 5 5
, IV 12 1
, VI A 1
, IV 7 19
IDU, V 2 49
INU, V 2 45
, V 2 45
, V 2 45
IDU ES, II 2 20
RAC ODU, II 3 13
NMS XP4, IV 10 15,
IV 10 23
, VI A
17
, I 1 6
TCP/IP, IV 2 21
DHCP, IV 2 23
, ,
V 2 11
, 1 i vi
, 1 i v
, 1 i vi
ODU, VI D 1
ODU, VI D 1
, IV 7 21
, IV 10 1
, III 3 3
, I 1 6
,
I 1 4
, IV 7 21
xi
, III 2 18
, III 2 18
, III 2 14
, II 3 126
, II 3
126
,
I 1 6
, I 1 2
, V 2 34
Ethernet,
V 2 38
IDU, V 2 34
AUX, V 2 38
,
V 2 37
, V 2
35
, II 1 3
, II 2 8
, II 2 36
, II 2 43
, II 2 38
, II 2 38
, IV 8 23,
IV 8 27
, II 2 36
PDH SDH,
, II 2
5
,
IV 7 27
, IV 8 23
xii
100, II 6 7
300, II 6 7
, II 2 6
FAN, V 2 39
Eclipse, 1 iii xxix
INU/INUe, IV 1 8
, I
13
, I 1 3
, I 1 3
, 1 i iii
, V 2 10
, V 2 10
,
V22
, I 1 4
IDU, III 4 4
INU/INUe, III 3 4, III 3 9
ODU RAC, III 3
13
RJ21 DAC
16x, III 3 13
, III 3 14
ProVision, V 2 3
, II 3 1
, V 2 23
AUX, V 2 29
DAC ES, V 2 30
DAC GE, V 2 31
DAC, V 2 28
FAN, V 2 34
NCC, V 2 24
NPC, V 2 29
RAC, V 2 25
, II 3 95
, II 3 96
, II 3 98
, II 3 92
, II 3 95
, II 3 92
-, II 3 4
, II 3 13
, II 3 2
, IV 9 1
, IV 7 1
,
II 3 146
, IV 8 4
PDH SDH, II 3 6
INU/INUe, II 3 1
, II 3
129
, II 3 3
RAC/ODU,
II 3 13
, II 3 16
Eclipse
, IV 1 7
, IV 1 8
Eclipse, 1 iii xxix
INU, II 1 9
Portal ProVision, II 1 18
,
IV 13 2
, IV 13 3
, IV 13 2
, IV 13 3
, IV 13 3
, VI F 1
, III 4 6
IDU, III 4 1
INU/INUe, III 3 1
ODU, III 2 2
Portal, IV 2 1, IV 2 2
, III 2 1
, III 2 1
Connect ES, III 4 6
, III 2 25
COM-, IV 2 13
, III 1 3
COM- WIN XP
Portal
WIN XP,
IV 2 14
ODU, III 2 20
n-, III 2 25
, VI A 7
Eclipse,
IV 13 2
Eclipse,
IV 3 8
, III 1 1
Win 2000
98, IV 2 14
, III 5 13
, III 2 14
857-000004-001, IV 2 2
, VI A
25
xiii
link, IV 15 45
, IV 15 45
, IV 15 45
, I 1 6
, V 1 4
NMS AUX, IV 7 93
NMS ,II 3 85
AUX, IV 7 93
, VI G 1
, I 1 6
, I 1 6
, II 1 19
, IV 7 13
, IV 15 45
, IV 10 8
, IV 15 45
, IV 15 57
link, IV 15 50
, IV 15
51
PRBS,
IV 15 61
, IV 15 69
DAC/
,
IV 15 58
, IV 15 72
, IV 15 72
xiv
, III 5 1
A
address learning
DAC ES, IV 7 64
AIS
AIS ,
IV 15 58
Andrew
GK400,
VI D 9
BR-400, VI D 7
ATPC
RAC 40, II 3 133
, IV 7 22
, IV 7 22
, IV 7 23
,
V 2 12
auto version
Portal, IV 1 9
AUX, II 1 15
, V 2
29, V 2 38
/
, IV 7 102
, IV 7 93
, IV 9 18
system/controls, IV 15 69
, II 3 89
, IV 7 98
-
, IV 9 21
B
BER
- , V 1 4
BER- ,
IV 15 61
C
clear events and history, IV 15 78
Connect ES
, II 2 29
, IV 4 4
, II 2 16
, II 2 32
, II 2 17
D
DAC
DAC 155oM , II 3 58
DAC 155oM ,
II 3 58
DAC 155oM, II 3 56
DAC 16x , II 3 48
DAC 16x, II 3 47
DAC 1x155o , II 3 55
DAC 1x155o, II 3 53
DAC 2x155e
DAC 2x155e, II 3 59
DAC 2x155e , II 3 60
DAC 2x155o, II 3 53
DAC 3xE3/DS3, II 3 49
DAC 3xE3/DS3M, II 3 51
DAC 4x , II 3 46
DAC 4x, II 3 46
DAC ES, II 3 61
address learning, IV 7 64
, IV
7 63
performance, IV 15 33
, IV 7
61
,
IV 15 66
, IV 7
64
, IV 7 64
DAC ES , II 3 66
DAC ES , II 3 66
DAC ES , II 3 69
DAC ES , II 3 64
DAC GE, II 3 70
address learning, IV 7 79
, IV 7 67
, IV
7 78
VLAN, IV 7 85
,
IV 7 89
RWPR, IV 7 79
performance, IV 15 41
, IV 7
76
,
IV 15 66
, IV 7
83
, IV 7 71
, IV 7 78
DAC GE RWPR, II 3 80
DAC GE . , II 3 79
DAC GE , II 3 77
DAC GE ,
II 3 79
DAC GE , II 3 82
xv
DAC GE , II 3 73
DAC GE , II 3
78
system/controls, IV 15 58
, II 3 115
, II 3 127
- , V
1 20
, II
3 127
,
II 3 127
, IV 8 13
, V 2 28
DAC 155o, IV 7 42
DAC 155oM, IV 7 47
DAC 16x DAC 4x, IV
7 31
DAC 2x155o, IV 7 42
DAC 2x155, IV 7 42
DAC 3xE3/DS3, IV 7
36
DAC 3xE3/DS3M, IV 7
38
DAC ES, IV 7 56
, IV 7 27
- DAC ES, IV 9
7
VLAN DAC GE, II 3 81
, II 3 45
, II 3 45
, IV 15 58
Address Learning DAC GE,
II 3 78
DAC GE, II 3 76
DAC 3xE3/DS3, II 3
50
DAC ES, IV 7 60
DAC GE, IV 7 72
NMS DAC 155oM, IV 7 53
DAC GE, II 3 78
DAC 155oM, II 1 14
DAC 16x, II 1 13
xvi
RJ-45
,
, VI E 5
RJ-21 RJ-45
-, VI E 4
, VI E 4
RJ-21
, VI E 8
RJ-21
BNC,VI-E-2
RJ-21
, VI E 10
1-8
, VI E 10
9-16
, VI E 12
, VI E 2
DAC 1x155o, II 1 14
DAC 2x155e, II 1 13
DAC 2x155o, II 1 14
DAC 3xE3/DS3, II 1 13
DAC 3xE3/DS3M, II 1 11
DAC 4x, II 1 12
RJ-45 RJ-45 IDU,
VI E 16
RJ-45 IDU
, VI E 19
RJ-45 BNC IDU
, VI E 14
RJ-45 RJ-45 IDU
-, VI E 17
RJ-45 IDU
, VI E 18
DAC ES, II 1 14
, V 2 30
DAC ES c , II 3 64
DAC GE, II 1 15
, V 2 31
DHCP
,
IV 10 17
fast
, IV 10 21
Portal, IV 2 10
, IV 10 17
diff , IV 1 9
DS1
,
IV 7 34
, II 3 8
Gigabit
, II 3 9
, V 2 38
Portal, IV 2 20
, II 3 108
Portal, IV 2 5
history, IV 15 24
performance DAC ES IDU ES,
IV 15 33
performance DAC GE, IV 15
41
Eclipse, II 6 4
, IV 15
66
, II 3 7
E
E1
,
IV 7 34
Eclipse
diff , IV 1 9
INU, II 1 9
INUe, II 1 10
ODUs, II 1 16
, II 6 12
, 1 iii xxx
, IV 4 3
, IV 4 3
Ethernet, II 6 4
, II 6
9
,
IV 4 9
, IV 4 10
, IV 4 9
, II 6 16
, II 6 1
, II 1 2
, II 2 1
, II 1 7
, II 1 11
, II 3 1
ESD, I 1 4
, I 1 4
Ethernet
F
factory tx mute, IV 7 12
FAN, II 1 11, II 3 22
, V 2
34, V 2 39
fast Ethernet, II 3 8
FEC, II 6 9
G
G.821
,
IV 15 61
Gigabit Ethernet, II 3 9
I
IDC V1, III 3 2
IDC V2, III 3 2
IDC, III 3 9
IDCe, III 3 9
IDU
IDU 155o, II 1 5
xvii
xviii
II 2 30
PDH SDH,
, II 2
5
, V 2 49
, III 4 3
IDU PDH SDH, II 2 8
,
II 2 44
, IV 7 1
AUX, IV 7 1
,
IV 7 1, IV 7 27,
IV 7 31
Portal, II 2 51
,
II 2 51
, II 2 53
/ AUX, II 2
7
, II 2 6
, IV 8 23
, II 2 10, II 2 29
IDU ES, II 2 17
PDH SDH, II 2 2
, II 2 10, II 2 29
, III 4 4
, III 4 1
, III 4 4
, III 4 5
, III 4 5
(Tmra),
III 4 4
IDU, III 4 6
DHCP,
II 2 52
, II 2 55
IDU 16x
, II 2 8
IDU ES
, IV 7 56
, II 2 20
IDU300 20x
, II 2 9
IEC
60950, I 1 1
INU
, V 2 45
, III 3 9
, III 3 2
INU/INUe
, III 3 1
, III 3 4
, III 3 1
, III 3 4
, III 3 5
, III 3 5
, III 3 4
, III 3 9
Tmra, III 3 4
INUe
, III 3 9
J
Java Runtime, IV 2 2
M
maint V.24
, VI E 22
N
NCC, II 1 11, II 3 19
NMS 10/100Base-T assembly, II 3 20
performance, IV 15 33
NPC, II 3 128
, V 2 24
, II 3 21
, II 3 20
, II 3
20
V.24 port, II 3 21
, II 3 21
, II 3 19
NMS
, VI
F1
X4, IV 10 23
DAC 155oM, IV 7 53
NMS 10/100Base-T
, VI E 21
NPC, II 1 15, II 3 90
, V 2 29
, II 3 91
NTP, IV 12 1
O
ODU, II 4 1
ODU 100, II 1 17
ODU 300, II 1 16
, III 2 22
, III 2 13
,
III 2 11
- ODU, III 2 24
, III 2 23
, III 2 23
ODU, III 2 21
, III 2 3
RAC, III 3 13
ODU,
III 2 21
, III 2
12
, III 2 8
, III 2 20
, II 4 3
, III 2 23
, III 2
21
, III 2 20
, III 2 21
, III
29
xix
, III 2 2
, II 4 1
5 GHZ, II 4 2
6 , II
42
OSPF, IV 10 2
, IV 10 2
, IV 10 8
P
performance
DAC ES, IV 15 33
DAC GE, IV 15 41
NCC, IV 15 33
, IV 15 31
performance , IV 15 31
Portal, II 5 1
auto version, IV 1 9
, V 2 23
, IV
33
, IV 1 1
,
IV 2 29
, IV 2 3
event browser, IV 15 8
system/controls, IV 15 45
Ethernet, IV 15 24
alarms, IV 15 14
history, IV 15 18
performance, IV 15 31
system summary, IV 15 2
,
IV 5 3
, IV 2 20
, VI A 9
, IV 2 29
, IV 8 1
, IV 2
32
V.24
xx
IP-, IV 2 33
- DAC ES, IV 9
7
- ,
IV 9 9
Ethernet, IV 2 20
V.24, IV 2 20
, IV
2 30
, VI
A 20
,
IV 7 1
, IV 11 1
, IV 9 1
AUX, IV
9 18
, VI A 8
, IV 3 5
, VI A 14
, IV 14 1
/, IV 12 1
, IV 10
1
Ethernet, IV 2
5
DHCP, IV 2
10
V.24
USB-, IV 2 16
V.24, IV 2
12
, IV 2 1
TCP/IP , IV 2 6
, IV 3 6
, IV 3 3
, IV 1 1
,
IV 1 3
, IV 1 3
/
, IV 1 2
, IV 1 1
, IV 1 5
, IV 1 3
, IV 1 2
, IV 15 1
as built report, IV 5 2
information, IV 6 1
layout, VI A 8
licensing, IV 4 7
parts, IV 15 75
, II 5 1
, IV 3 2
, II 5 3
, II 5 2
, IV 3 2
, IV 3 3
, IV 5
1
, IV
33
DHCP-, IV 2 25
TCP/IP,
IV 2 21
, IV 1 8
V.24, IV 2 32
Eclipse,
IV 4 11
, IV
2 31
, IV 2 2
, IV 2 28
,
IV 3 1
V.24 COM- DB-9
, IV 2 13
DHCP, IV 2 23
V.24, IV 2 26
, IV 2 1
, IV 2 2
, IV
22
, IV 13 1
,
IV 13 1
, IV 2 1
, IV 2 2
ProVision, II 5 5
, II 5
6
, II 5 6
,
II 5 1
, II 5 5
, V 2 3
R
RAC
RAC 30, II 3 23
RAC 3X, II 3 23
RAC 40, II 3 41
RAC10, II 3 40
, IV 8 13
, V 2 25
, II 3 23
, II 3 118
RAC 10V1,
II 3 122
RAC 10V1, II 3 120
RAC 10, II 1 12
RAC 30, II 1 11
, II 3 39
RAC 3X, II 1 12
RAC 40, II 1 12
, II 3 143
xxi
,
II 3 135
, II 3
134
INU,
II 3 133
, II 3 139
, II 3 133
, II 3 132
, ,
ATPC, II 3 133
4+4 quattro, II 3
145
, II 3 131
RAC/IDU ODU
,
VI C 5
RIP, IV 10 2
RJ-45
, ,
VI E 5
RSL
, III 5 3
, III 5 2
RSSI
, III 5 2
RWPR, II 3 80, II 3 111
RX, VI E 10, VI E 19
T
TCP/IP
Portal, IV
26
Tmra
, I 1 6
TX, VI E 10, VI E 19
tx mute
link, IV 15 45
U
USB , IV 2 16
V
V.24
Portal, IV 2 20
, IV 2 32
V.24
USB-, IV 2 16
Portal, IV 2 12
IP- Eclipse, IV 2 33
Portal COM- DB-9
, IV 2 13
VLAN DAC GE, II 3 76
S
SELV, I 1 2
software reset, IV 15 77
Stratex Networks
, 1 i iv